• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 566
  • 154
  • 15
  • 14
  • 10
  • 10
  • 7
  • 5
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • Tagged with
  • 830
  • 385
  • 223
  • 103
  • 98
  • 95
  • 75
  • 74
  • 70
  • 69
  • 69
  • 67
  • 64
  • 63
  • 60
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
301

Vztah exprese markerů kloubního zánětu k aktivitě revmatoidní artritidy. / Markers of joint inflammation related to disease activity in rheumatoid arthritis.

Hurňáková, Jana January 2018 (has links)
Background: Rheumatoid arthritis (RA) is a common chronic autoimmune disorder characterised by persistent synovitis, typically manifested as symmetric polyarthritis of small hand joints with various extra-articular manifestations. Accurate disease activity measurement is a key component of RA management that facilitates therapeutic optimalization in order to slow down the disease progression and to prevent an irreversible joint damage. The aim of this work was to study the role of candidate serum inflammatory markers and their associations with the disease activity in patients with RA presented by traditional variables of disease activity as well as by musculoskeletal ultrasonography. Results: The first part of our work pointed out relationship between serum calprotectin and clinical as well as ultrasound activity in RA. We have revealed that serum calprotectin is an independent predictor of ultrasound synovitis. Moreover, we have demonstrated the potential of calprotectin to identify patients with residual activity in spite of achieving clinical remission. In the second part, we have provided a detailed analysis of 20 candidate serum markers and found out a tight associations between IL-6, IL-7, IL-22, IL-34, YKL-40, CXCL-13, MMP-3, resistin and visfatin with clinical and ultrasound activity....
302

Nível sérico de ácido hialurônico e sua relação com o escore ultra-sonográfico na avaliação da hepatopatia em pacientes com fibrose cística

Rocha, Renata Gonçalves January 2007 (has links)
A hepatopatia da fibrose cística (FC) é uma complicação grave sendo descrita como terceira causa de morte nestes pacientes. Sua prevalência é muito variável, desde 14,3% até 41% em crianças e adolescentes. A discrepância entre os diferentes estudos clínicos se deve à forma utilizada para o diagnóstico da hepatopatia (características clínicas, bioquímicas e/ou ultra-sonográficas), à idade dos pacientes selecionados, ao tipo de estudo empregado (transversal ou longitudinal) e também, à falta de um marcador específico e sensível de disfunção hepatobiliar. Em 1995, Williams et al, elaboraram um escore ultra-sonográfico que mostrou boa relação com as alterações laboratoriais hepáticas pretendendo, desta forma, graduar o nível da lesão hepática. O escore foi elaborado por meio da avaliação do padrão do parênquima hepático, do contorno do fígado e do grau de ecogenicidade periportal. Quanto aos marcadores não invasivos para diagnosticar a doença hepática, vários tem sido estudados, entre eles o ácido hialurônico (AH).O AH é o maior mucopolissacarídeo componente da matriz extracelular, é encontrado na maioria dos tecidos e fluidos corporais, particularmente abundante em tecido conectivo frouxo. É sintetizado na membrana citoplasmática de fibroblastos e de outras células, sendo que uma pequena parte é metabolizada neste local. Através dos vasos linfáticos chega à corrente sanguínea e é rapidamente eliminada pelo fígado, ao nível do sinusóide hepático. Neste estudo buscamos relacionar as alterações ultra-sonográficas com o nível sérico de AH e, desta forma, realizar o diagnóstico precoce da hepatopatia da FC. Foi realizado um estudo transversal em 57 pacientes com FC, todos caucasóides, que apresentavam uma média de idade de 10,2 + 4,9 anos. A avaliação constou de dados clínicos, laboratoriais e ultra-sonográficos. Os pacientes foram classificados de acordo com um escore ultra-sonográfico em:Grupo 1 (G1) – ausência de doença hepática: escore 3; - Grupo 2 (G2) – doença hepática moderada: escore 4 – 6; - Grupo 3 (G3) – doença hepática grave: escore 7 - 9. O nível sérico do ácido hialurônico foi medido através da técnica de ELISA (Enzyme Linked Immunoassay) e comparado com 23 controles saudáveis. Vinte e nove pacientes foram incluídos no G1, dezoito pacientes no G2 e dez pacientes no G3. Os pacientes do sexo masculino apresentaram escore ultra-sonográfico mais alterado (P= 0,018). O nível sérico da ALT e da AST foram consideravelmente mais elevados no G3 do que no G1. O nível sérico da GGT foi mais elevado no G3 do que no G1 e G2. A porcentagem do volume expiratório forçado no primeiro segundo (%VEF1) apresentou uma correlação positiva fraca com o escore Z P/I (r= 0,31/P= 0,031). O nível sérico de AH variou de 1,8 a 45 ng/mL (mediana= 13,9), apresentou uma mediana semelhante entre os grupos 1,2,3 e o grupo controle (P= 0,431), entre os grupos 1,2 e 3 (P= 0,24) e também, quando comparado cada grupo com o grupo controle (todos P> 0,1). Não houve correlação entre o nível sérico de AH e o escore ultra-sonográfico (P= 0,164). Desta forma, concluímos que o AH isoladamente não se mostrou um marcador da hepatopatia causada pela fibrose cística. / Cystic fibrosis (CF) liver disease (LD) is a serious complication, being described as the third cause of death in these patients. Its prevalence varies widely, from 14.3% to 41.0% in children and adolescents. The discrepancy shown by the various clinical studies is due to the method employed for the diagnosis of LD (clinical, biochemical and/or ultrasonographic characteristics), the age of selected patients, the type of study (crosssectional or longitudinal) and the absence of a specific and sensitive marker. In 1995, WILLIAMS et al, developed an ultrasonographic score that showed a good relation to liver biochemical alterations, in order to measure the liver involvement. The score was elaborated through an evaluation of three cardinal features of hepatic ultrasound in CF: coarseness of the parenchyma, nodularity of the liver edge and increased periportal echogenicity. Regarding non-invasive markers to diagnose the hepatic disease, several have been studied, among them the hyaluronic acid (HA). Hyaluronic acid is a major mucopolysaccharide in the extracellular matrix, found in most body tissues and fluids, particularly abundant in loose connective tissue. It is synthetized in the cytoplasmatic membrane of fibroblasts and other cells, with a small part being metabolized there. Through the lymph vessels, it reaches the bloodstream and is rapidly eliminated by the liver, at the hepatic sinusoid level. In this study, we attempted to correlate the ultrasound findings with HA serum level, and thus, obtain the early diagnosis of CFLD. A cross-sectional study was performed with 57 patients with CF, all white individuals presenting mean age of 10.2 + 4.9 years. The evaluation considered clinical, laboratorial and ultrasonographic data. The patients were classified according to an ultrasonographic score into: - Group 1 (G1) – absence of liver disease: score 3- Group 2 (G2) – moderate liver disease: score 4 – 6; - Group 3 (G3) – severe liver disease: score 7 - 9. HA serum level was measured by ELISA (Enzyme Linked Immunoassay) in the CF patients and 23 healthy controls. Twenty-nine patients were included in G1, 18 in G2 and 10 in G3. The male patients presented an ultrasonographic score with more alterations (P= 0,018). The serum levels of ALT and AST in G3 were considerably higher than in G1. The serum level of GGT in G3 was higher than in G1 and G2. The percent of forced expiratory volume in the first second (%FEV1) presented a small positive correlation with Z score W/A (r= 0.31/P= 0.031). HA serum level ranged from 1.8 to 45 ng/mL (mean = 13.9), and presented a similar mean value between Groups 1,2,3 and the control group (P= 0.431), among Groups 1,2 and 3 (P= 0.24), as well as when comparing each group to the control group (all P> 0.1). There was no correlation between HA serum level and ultrasonographic score (P= 0.164). Thus, we concluded that HA lonely cannot be considered as a marker of liver disease caused by cystic fibrosis.
303

Estudo dopplerfluxométrico renal de quatis (Nasua nasua, Linnaeus, 1766) de vida livre / Renal dopplerfluxometry in free-ranging coatis (Nasua nasua, Linnaeus, 1766)

Inamassu, Letícia Rocha [UNESP] 24 September 2015 (has links) (PDF)
Made available in DSpace on 2018-07-27T18:26:06Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-09-24. Added 1 bitstream(s) on 2018-07-27T18:30:16Z : No. of bitstreams: 1 000866563.pdf: 1395862 bytes, checksum: f087812e01be98a31c3e2c13e6971a7d (MD5) / A população de quatis tem aumentado consideravelmente, principalmente em parques públicos, fato que aumenta a preocupação com relação a ocorrência das doenças de caráter zoonótico. Existem poucos relatos do emprego da ultrassonografia convencional e Doppler na avaliação renal desses animais, assim como auxilio no diagnóstico das doenças nessa espécie. Portanto, o trabalho teve por objetivo avaliar pela ultrassonografia convencional as características de ecogenicidade comparativa dos rins e detectar, ao exame Doppler, um perfil do índice de resistividade das artérias intrarrenais de quatis de vida livre, sob contenção química. Foram avaliados 17 quatis, 4 machos e 13 fêmeas. Uma correlação positiva foi observada entre o peso (2,5 até 9,3 Kg) e comprimento dos rins (2,73 a 4,07 cm). Todos os quatis apresentaram adequada definição e proporção córtico-medular, com córtex hiperecogênico em relação à medular, mantiveram a mesma relação de ecogenicidade entre parênquima esplênico, hepático e córtex renal que os observados em cães e gatos. Foi obtido o índice de resistividade (IR) das artérias intrarrenais, com média de 0,63 ± 0,06 (variando de 0,49 a 0,82) e com pressão arterial sistêmica (PAS) média de 94 mmHg, valores de IR superiores aos encontrados nos cães e gatos não sedados. Não foi observado correlação positiva entre a PAS e o IR intrarrenal nos animais submetidos a combinação de cetamina, xilazina e midazolam. O IR desses animais deverá ser mensurados com outras combinações químicas de anestésicos / Coati's population has increased considerably, especially in public parks, which increases the concern about the occurrence of zoonotic diseases. There are few reports of the use of conventional and Doppler ultrasound in renal evaluation of these animals, as well as an aid in the disease diagnosis in this species. Therefore, the study aimed to assess by conventional ultrasound the characteristics of comparative echogenicity of the kidneys and to detect at Doppler examination, a profile of the resistivity index of intrarenal arteries of free ranging coatis under chemical restraint. Seventeen coatis, 4 males and 13 females, were evaluated. A positive correlation was observed between body weight (from 2.5 to 9.3 kg) and renal length (from 2.73 to 4.07cm). All coatis had adequate cortico-medullary definition and ratio, with a hyperechoic cortex relative to the medulla, maintaining the same echogenicity relationship between splenic and hepatic parenchyma and renal cortex than those observed in dogs and cats. The resistive index (RI) was obtained from the intrarenal arteries, averaging 0.62 ± 0.06 (range 0.49 to 0.71) and mean systemic arterial pressure (SAP) of 95.06 mmHg, a higher RI than those found in dogs and cats not sedated. There was no positive correlation between SAP and renal RI in the animals submitted to a combination of ketamine, xylazine and midazolam. The RI of these animals should be measured with other chemical combinations of anesthetics
304

Avaliação ultrassonográfica de tumores mamários e linfonodos locorregionais em cadelas /

Simm, Rejane Guerra Ribeiro. January 2016 (has links)
Orientador: Andrigo Barboza De Nardi / Coorientador: Naida Cristina Borges / Banca: Manuela Cristina Vieira / Banca: Tiago Luís Eilers Treichel / Banca: Luís Gustavo Gosuen Gonçalves Dias / Banca: Annelise Carla Camplesi dos Santos / Resumo: O exame ultrassonográfico convencional tem baixa especificidade para detecção de alterações difusas, no entanto, o aumento da ecogenicidade renal é um dos achados mais comuns em cães e gatos com nefropatia. O objetivo deste estudo foi descrever a técnica de elastografia por irradiação da força de impulso acústico (ARFI) na avaliação dos rins de gatos adultos hígidos, e determinar os valores de referência. Foram incluídos neste trabalho dez gatos de pelo curto, adultos e saudáveis. Após sedação, foi realizada uma ampla tricotomia abdominal, para a realização do exame ultrassonográfico. O exame convencional, em Modo B foi realizado com um transdutor linear de 9,0 MHz usando equipamento de ultrassom ACUSON S2000 / SIEMENS (Siemens, Munique, Alemanha). A ecogenicidade, ecotextura, o tamanho e contornos renais foram avaliados. Com o mesmo transdutor, a elastografia foi realizada utilizando software para comparação das análises qualitativa e quantitativa do método. A elastografia qualitativa detectou a presença de deformidades e as velocidades de cisalhamento em diferentes locais (cranial, média e caudal) das regiões cortical e medular em ambos os rins. Os achados ultrassonográficos foram considerados normais em todos os gatos, sem alterações em arquitetura ou ecogenicidade renal. A elastografia qualitativa demonstrou que o córtex renal era deformável e apresentou áreas cinza escuro homogêneas; pelve renal tinha pouca rigidez (branca); e da medula mostrou um padrão de mosaico. Os r... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Conventional ultrasonography has low specificity to detect diffuse changes, however, increased renal echogenicity is one of the most common findings in dogs and cats with nephropathy. The objective of this study was to describe elastography by acoustic radiation force impulse (ARFI) in the assessment of adult cats' kidneys and determine reference values. Ten healthy adults short hair cats were included. After sedation, abdominal hair was clipped in order to perform ultrasound exams. The conventional examination (B-mode) was performed with a 9.0 MHz linear array transducer ultrasound equipment using ACUSON S2000/Siemens (Siemens, Munich, Germany). Echogenicity, echotexture, size and contours of each kidney were evaluated. With the same transducer, elastography was performed using a software that compares qualitative and quantitative analysis. Qualitative elastography detected deformities and shear wave velocity rates in different portions (cortical and medulla' cranial, media and caudal regions). The sonographic findings were normal in all cats, with no changes in renal architecture or echogenicity. Qualitative elastography showed that renal cortex was softer with dark gray homogeneous areas; renal pelvis presented lower stiffness (white); and medulla showed a mosaic pattern. Shear wave velocities were obtained in cranial, medial, and caudal regions of the cortex and medulla: 2.46 m/s ± 0.45m/s; 2,46m/s ± 0.48 m/ s 2,37 m/s ± 0, 42 m/s (P = 0.795) in the cortex and 1.61 m/s ± ... (Complete abstract click electronic access below) / Doutor
305

Julgamento perceptivo-auditivo e perceptivo-visual das produções gradientes de fricativas coronais surdas / Perceptual-auditory and perceptual-visual judgment of the productions gradients of deaf coronal fricatives

Lima, Fernanda Leitão de Castro Nunes de [UNESP] 22 May 2018 (has links)
Submitted by FERNANDA LEITAO DE CASTRO NUNES DE LIMA (fernandaleitao@live.com) on 2018-06-19T04:27:15Z No. of bitstreams: 1 Dissertação Final.pdf: 1310670 bytes, checksum: ab7f761d3d1be439f987de5d800203cd (MD5) / Approved for entry into archive by Satie Tagara (satie@marilia.unesp.br) on 2018-06-19T14:10:24Z (GMT) No. of bitstreams: 1 lima_flcn_me_mar.pdf: 1310670 bytes, checksum: ab7f761d3d1be439f987de5d800203cd (MD5) / Made available in DSpace on 2018-06-19T14:10:24Z (GMT). No. of bitstreams: 1 lima_flcn_me_mar.pdf: 1310670 bytes, checksum: ab7f761d3d1be439f987de5d800203cd (MD5) Previous issue date: 2018-05-22 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Objetivo: O objetivo do presente estudo foi analisar a porcentagem de respostas dos juízes no julgamento perceptivo-auditivo dos áudios e no julgamento perceptivo-visual de imagens ultrassonográficas na detecção de produções gradientes das fricativas coronais surdas. Ainda, verificar se há diferenças entre essas formas de julgamento e se elas se correlacionam. Métodos: Foram selecionados 20 juízes com conhecimento sobre o processo de produção da fala, além da classificação e descrição fonética dos diferentes fonemas do Português Brasileiro (PB). Os estímulos julgados foram coletados de um banco de dados, arquivos de áudio e vídeo (imagens ultrassonográficas) relativos à produção de palavras “sapo” e “chave”, de 11 crianças falantes do PB, na faixa etária de 6 a 12 anos de idade (9 meninos e 2 meninas), com produção de fala atípica. Foi realizada uma codificação prévia dos arquivos coletados. Após instrução prévia, os juízes deveriam escolher, imediatamente à apresentação de um estímulo, uma dentre três opções dispostas na tela do computador.O procedimento experimental consistiu no julgamento dos arquivos de áudio e julgamento das imagens ultrassonográficas, executado pelo software PERCEVAL.No julgamento dos arquivos de áudio as opções eram: produção correta, incorreta ou gradiente, enquanto no julgamento das imagens ultrassonográficasas opções eram: produção de [s], produção de [∫] ou produção indiferenciada.O tempo de apresentação, o modo aleatorizado de seleção dos estímulos e o tempo de reação foram controlados automaticamente pelo software PERCEVAL. Os dados foram submetidos à análise estatística. Resultados: O julgamento de imagens propiciou uma maior identificação dos estímulos gradientes (137 estímulos) e um menor tempo de reação na realização da tarefa (média=1073,12 ms) comparativamente ao julgamento perceptivo-auditivo (80 estímulos, tempo de reação médio=3126,26 ms), ambos estatisticamente significante (p<0,00). O teste de correlação de Spearman não mostrou significância estatística para porcentagem de respostas, nem para o tempo de reação. Conclusão: O uso das imagens ultrassonográficas no julgamento é o método mais sensível para a detecção da produção gradiente na produção de fala, podendo ser utilizado como método complementar do julgamento perceptivo-auditivo na análise de fala. / Purpose: The purpose of this study was to analyze the percentage of judges' answers in the auditory-perceptual judgment of the audios and in the visual-perceptual judgment of ultrasound images in the detection of gradient productions of the voiceless coronal fricatives. Also, to verify whether there are differences between these forms of judgment and whether they correlate. Methods: 20 judges with knowledge about the speech production process, besides the phonetic classification and description of the different Brazilian Portuguese (BP) phonemes were selected. The judged stimuli were collected from a database, audio and video files (ultrasound images) related to the production of "sapo”(frog) and "chave" (key) words, of 11 BP speakers children aged from 6 to 12 years old (9 boys and 2 girls), with atypical speech production. A previous encoding of the collected files was performed. After previous instruction, the judges should choose, immediately the presentation of a stimulus, one of three options arranged on the computer screen. The experimental procedure consisted in the judgment of the audio files and judgment of the ultrasound images, executed by the PERCEVAL software. In the judgment of the audio files the options were: correct, incorrect or gradient production, while in the judgment of the ultrasound images the options were: production of [s], production of [∫] or undifferentiated production. The presentation time, the randomized mode of selection of the stimuli and the reaction time were controlled automatically by PERCEVAL software. The data were submitted to statistical analysis. Results: The judgment of images provided a greater identification of the gradient stimuli (137 stimuli) and a shorter response time (mean = 1073.12 ms) compared to the auditory-perceptual judgment (80 stimuli, mean reaction time = 3126.26 ms), both statistically significant (p <0.00). Spearman's correlation test did not show statistical significance for percentage of responses, nor for reaction time. Conclusion: The use of ultrasound images in the judgment is the most sensitive method for the detection of gradient production in speech production, and can be used as a complementary method of auditory-perceptual judgment in the speech analysis.
306

Efeitos renais da administração intravenosa de meios de contraste iodado em cães submetidos à tomografia computadorizada: aspectos ultrassonográficos e laboratoriais / Renal effects of intravenous administration of iodinated contrast media in dogs undergoing computed tomography: ultrasonographic and laboratory aspects

Claudia Matsunaga Martin 11 September 2015 (has links)
A nefropatia induzida por contraste (NIC) é uma nefropatia aguda, secundária à administração intravascular de meios de contraste iodado (MCI), cujas propriedades físico-químicas, especialmente a osmolaridade, relacionam-se ao seu desenvolvimento. Dentre os mecanismos fisiopatológicos desta enfermidade destacam-se a vasoconstrição intrarrenal prolongada, consequente redução da perfusão renal, hipóxia e isquemia medulares, associada ao dano tubular renal devido à citotoxicidade do contraste. Frente à existência de poucas informações relacionadas a estes mecanismos na literatura médico-veterinária e a grande demanda de exames de tomografia computadorizada que utilizam contrastes, objetivaram-se caracterizar e comparar os efeitos renais da administração intravenosa de MCI não iônicos de diferentes osmolaridades, em grupos de cães com fatores de risco para o desenvolvimento da NIC, por meio das avaliações ultrassonográficas modo B, Doppler colorido, de amplitude e pulsado, pareada aos exames laboratoriais, a fim de estimar indiretamente o potencial nefrotóxico de cada contraste. Este estudo também objetivou verificar a ocorrência da NIC. Constituíram-se dois grupos de acordo com o MCI utilizado: o grupo GIH (11 cães receberam iohexol [baixa osmolaridade]) e o grupo GID (sete cães receberam iodixanol [isosmolar]). Administrou-se a dose de 600 mgI/kg/IV em ambos. Avaliaram-se os seguintes aspectos renais antes da administração do MCI (momento basal) e após 1,5 horas, 24 horas e 48 horas: morfometria (comprimento e volume), morfologia, ecogenicidade cortical e perfusão renais e resistência vascular intrarrenal (índices hemodinâmicos de resistividade e pulsatilidade), realizou-se ainda exame de urina I e se mensuraram as razões gama-glutamil transferase:creatinina (GGT:C) e proteína:creatinina (RPC) urinárias e a concentração sérica de creatinina. Estipulou-se avaliar os aspectos sonográficos do rim esquerdo, desde que ambos os rins apresentassem características morfométricas, morfológicas, de ecogenicidade cortical e perfusão, semelhantes na abordagem inicial de cada paciente. Os grupos apresentaram comportamentos similares para comprimento, RPC, exame de urina I e creatinina sérica. Constataram-se aumentos significativos do índice de resistividade (IR) e da razão GGT:C urinária e evidências de aumento significativo do volume renal, 1,5 horas após a administração do contraste, somente no grupo que recebeu iohexol. Em relação ao índice de pulsatilidade, embora ambos os grupos tenham apresentado comportamentos não similares, não se detectaram diferenças significativas entre o momento basal e os demais. Concluiu-se que o IR foi capaz de monitorar a hemodinâmica intrarrenal e demonstrar, assim como a razão GGT:C urinária, maior potencial nefrotóxico do iohexol, quando comparado ao iodixanol. Dessa forma, considerou-se o iodixanol uma opção favorável para cães com fatores de risco para o desenvolvimento da NIC. Um cão de 14 anos de idade, portador de insuficiência cardíaca e disfunção renal preexistente, desenvolveu a forma subclínica da NIC, reconhecida pela elevação de 0,5 mg/dL na creatinina sérica basal, 24 horas após a administração intravenosa do iohexol. A redução da perfusão renal verificada 1,5 horas após a utilização do contraste pode ser preditiva de NIC. De modo semelhante ao observado no homem, idade avançada, insuficiência cardíaca e disfunção renal preexistente, principalmente quando associadas, constituem fatores de risco para o desenvolvimento da NIC em cães / Contrast-induced nephropathy (CIN) is a type of acute nephropathy, secondary to intravascular administration of iodinated contrast media (ICM). The physicochemical properties of ICM, particularly the osmolarity of the media, are related to the development of CIN. The most important mechanisms of this nephropathy are intrarenal prolonged vasoconstriction, medular hypoxia, and ischemia associated with renal tubular damage due to contrast cytotoxicity. Owing to the limited information available in veterinary literature regarding these mechanisms and increase in the number of contrast-enhanced computed tomography examinations performed, this study aims to characterize and compare the renal effects of intravenous administration of two nonionic ICM of different osmolarities in groups of dogs with risk factors for CIN development, by using a B-mode, color, power- and pulsed-wave Doppler ultrasonography, and other laboratory tests, in order to indirectly estimate the nephrotoxic potential of each contrast. This study also aims to investigate the occurrence of CIN. The following two groups were established according to the nonionic ICM used: the GIH group (11 dogs administered iohexol [low osmolarity]) and the GID group (seven dogs administered iodixanol [iso-osmolarity]). Both the groups were administered the same dose (600 mgI/kg/IV). The following renal aspects were evaluated before administration of ICM (baseline) and after 1.5 h, 24 h, and 48 h: renal morphometry (length and volume), renal morphology, cortical echogenicity, renal perfusion, and intrarenal vascular resistance (resistive and pulsatility indices); in addition, urinalysis was performed, and urinary gamma-glutamyl transferase:creatinine ratio (GGT:C), urinary protein:creatinine ratio (UPC), and serum creatinine were also measured. The sonographic aspects of the left kidney were evaluated, only if both kidneys presented similar morphometry, morphology, cortical echogenicity, and perfusion during the first assessment of each patient. Both groups showed similar characteristics with respect to the length, UPC ratio, urinalysis, and serum creatinine levels. Significant increases were observed in the resistive index (RI) and urinary GGT:C, and evidence of significant increase was observed in the renal volume only in the GIH group, 1.5 h after contrast administration. No similarity was observed with respect to the pulsatility index in both the groups; however, there were no significant differences between baseline and 1.5-, 24- and 48-h time points. In conclusion, RI can be used to monitor intrarenal hemodynamics, and along with the urinary GGT:C, revealed that iohexol had higher nephrotoxic potential than iodixanol. Thus, iodixanol was considered a favorable option for dogs with risk factors for CIN development. A 14-year-old dog with heart failure and pre-existing renal dysfunction developed subclinical CIN, due to an increase in the serum creatinine (0.5 mg/dL) 24 h after intravenous iohexol administration. The decrease in renal perfusion observed 1.5 h after ICM administration may be predictive of CIN. As observed in humans, advanced age, heart failure, and pre-existing renal dysfunction, especially various associated factors, should be considered as risk factors for the development of CIN in dogs
307

Avaliação da espessura dos músculos mastigatórios e da força de mordida molar máxima em indivíduos portadores de toro mandibular / Evaluation of the masticatory muscles thickness and the maximum molar bite force in subjects with mandibular torus

Cassia Perola dos Anjos Braga Pires 06 August 2014 (has links)
O sistema estomatognático identifica um conjunto de estruturas bucais que desenvolvem funções comuns, tendo como característica constante a participação da mandíbula. Como todo sistema, tem características que lhe são próprias, mas depende do funcionamento, ou está intimamente ligado à função de outros sistemas como o nervoso, o circulatório e o endócrino. Tanto nos estados de saúde como nos de enfermidade, o sistema estomatognático pode influir sobre o funcionamento de outros sistemas como o digestório, respiratório e o metabólico-endócrino. Várias são as doenças e eventos clínicos que podem acometer o sistema estomatognático, acarretando o seu desequilíbrio ou mau funcionamento. Este estudo teve como objetivo analisar a espessura muscular e a força de mordida em 20 indivíduos diagnosticados com toro mandibular (Grupo Casos) e em 20 indivíduos sem toro (Grupo Controles). Para a análise ultrassonográfica foi utilizado o ultrassom portátil da marca NanoMaxx, com um transdutor linear - L 25 - de 06 a 13 MHz e 23 mm. Foram adquiridas três imagens ultrassonográficas dos músculos masseter e temporal, de ambos os lados, na posição de repouso e de contração voluntária máxima. Os registros da força de mordida foram realizados utilizando o dinamômetro digital, modelo IDDK (Kratos). As avaliações foram feitas nas regiões do primeiro molar (direito e esquerdo). Verificou-se que, os indivíduos portadores de toro na mandíbula apresentaram espessura dos músculos temporais significantemente menores que a dos indivíduos do Grupo Controles, enquanto que, os resultados para a força de mordida máxima foram significativamente maiores para os indivíduos do Grupo Casos e que não ocorreram correlações entre as espessuras e a força de mordida. Concluiu-se que a presença de toro mandibular promoveu alterações no sistema estomatognático. / The stomatognathic system has a set of oral structures that develop common functions, having as a constant share of the jaw. Like any system, it has characteristics of its own, but depends on the functioning, or is closely linked to the function of other systems such as the nervous, circulatory and endocrine. Both the states of health and illness in the stomatognathic system can influence the operation of other systems such as the digestive, respiratory and metabolic - endocrine. There are many diseases and clinical events that may affect the stomatognathic system, causing your imbalance or dysfunction. This study aimed to analyze the muscle thickness and bite force in 20 individuals diagnosed with mandibular torus (Cases Group) and 20 individuals without torus (Controls Group). For the analysis we used the ultrasound portable NanoMaxx, with a linear transducer - L 25 - 06-13 MHz and 23 mm. Three ultrasound images were acquired from masseter and temporalis muscles on both sides, at rest and maximal voluntary contraction. The records of bite force were performed using the digital dynamometer, IDDK model (Kratos). The assessments were made in the regions of the first molar (right and left). It was found that individuals with mandibular torus showed temporalis muscles thickness significantly lower than Controls Group subjects, whereas the results for the maximum bite force were significantly higher for Cases Group subjects, and there were no correlations between the thicknesses and the bite force. It was concluded that the presence of mandibular torus promoted changes in the stomatognathic system.
308

Avaliação ultrassonográfica e dopplervelocimétrica da esquistossomose mansônica: estudo de campo em áreas de baixa, média e alta endemicidades / Ultrasonographic and dopplervelocimetric evaluation of schistosomiasis mansoni: field-based study in areas of low, medium and high endemicity

Leticia Martins Azeredo 05 October 2009 (has links)
INTRODUÇÃO: os principais aspectos clínicos da esquistossomose mansônica (EM) são determinados pelas lesões vasculares e suas repercussões na hemodinâmica portal. O acesso não-invasivo a essas alterações tem importância fundamental na avaliação da morbidade da doença e na identificação de pacientes com maior risco de complicações. Este estudo de campo realizado em três áreas com níveis distintos de endemicidade, objetivou: a) verificar a viabilidade da USDoppler em estudos de campo; b) identificar os sinais de morbidade relacionados à EM e correlacioná-los com a endemicidade das áreas estudadas; c) determinar os valores dopplervelocimétricos do sistema vascular esplâncnico na EM; e d) determinar as alterações hemodinâmicas na EM. CASUÍSTICA E MÉTODOS: foram examinados por meio da US-Doppler, 554 pacientes esquistossomóticos, divididos em três grupos, de acordo com o local de realização do exame: área de baixa endemicidade (n=109); área de média endemicidade (n=255) e área de alta endemicidade (n=190). Avaliaram-se o fígado, o baço, a vesícula biliar, os vasos portais, as artérias hepática e esplênica, as veias hepáticas e os vasos colaterais. Para análise da morbidade da doença, foi utilizado o protocolo do Niamey Working Group (2000). O protocolo Doppler foi elaborado para fins específicos desta pesquisa. RESULTADOS: houve correlação estatisticamente significante entre as frequências de: espessamento periportal, esplenomegalia, espessamento da parede da vesícula biliar, aumento do calibre dos vasos portais, redução do lobo direito e o nível de endemicidade das áreas. Não houve relação significativa entre a hipertrofia do lobo esquerdo e a endemicidade das áreas. Considerando-se os achados ultrassonográficos de espessamento periportal e/ou esplenomegalia, os pacientes foram alocados em quatro grupos de acordo com a forma de apresentação da doença. As formas hepatointestinal e hepatoesplênica foram mais frequentes na área de alta endemicidade, demonstrando associação significativa entre o nível de endemicidade e a gravidade da doença. A velocidade máxima de fluxo da veia porta apresentou valores normais na maioria dos casos. O fluxo hepatofugal, a trombose portal e a circulação colateral foram pouco frequentes e identificados apenas na área de alta endemicidade. A veia gástrica esquerda foi a colateral prevalente. As veias hepáticas apresentaram padrão de fluxo alterado em 1/4 dos casos, alteração essa relacionada à presença e à intensidade de espessamento periportal. A artéria hepática não apresentou alterações significativas nos parâmetros avaliados. As alterações da artéria esplênica (aumento do calibre, da velocidade de pico sistólico e do índice de resistividade) foram mais frequentes na área de alta endemicidade e na forma hepatoesplênica, com diferença significativa entre os grupos. CONCLUSÃO: a US-Doppler mostrouse viável e adequada para avaliação das alterações hemodinâmicas da EM em estudos de campo. Os sinais de morbidade detectados ultrassonograficamente são parâmetros fidedignos do nivel de endemicidade da EM, e, as informações funcionais do sistema portal obtidas pela US-Doppler, contribuem para o diagnóstico mais preciso das formas clínicas da doença nas áreas endêmicas / INTRODUCTION: The main clinical aspects of schistosomiasis mansoni (SM) are determined by vascular lesions and their effects on the portal hemodynamic. The non-invasive access to these alterations has fundamental importance in assessing the morbidity of the disease and in identifying patients at higher risk of complications. This field study, carried out in three areas with different levels of endemicity, aimed to: a) assess the feasibility of Doppler ultrasound (US) in fieldbased studies; b) identify the signs of morbidity related to SM and correlate them with the endemicity of the studied areas; c) determine the dopplervelocimetric values of the splanchnic vascular system in SM; and d) determine the hemodynamic changes in SM. PATIENTS AND METHODS: Doppler US was performed in 554 patients with SM, divided into three groups according to the local of the examination: low endemicity area (n=109), medium endemicity area (n=255), and high endemicity area (n=190). The liver, the spleen, the gallbladder, the portal vessels, the hepatic and splenic arteries, the hepatic veins and collateral vessels were evaluated. The Niamey Working Group (2000) protocol was used for the disease morbidity analysis. The Doppler protocol was developed for the specific purposes of this study. RESULTS: There was a statistically significant correlation between the frequency of: periportal thickening, splenomegaly, gallbladder wall thickening, dilatation of the portal vessels, right lobe atrophy and the endemicity level of the areas. No significant correlation between the left lobe hypertrophy and the endemicity level was observed. Taking into account the US findings of periportal thickening and/or splenomegaly, the patients were allocated in four groups according to the form of the disease. The hepatointestinal and hepatosplenic forms were more frequent in the high endemicity area, showing a significant association between the endemicity level and the disease severity. The maximum flow velocity in portal vein showed normal values in most cases. The hepatofugal flow, portal vein thrombosis and collateral vessels were infrequent and identified only in the area of high endemicity. The left gastric vein was the prevalent collateral. The hepatic veins flow pattern was abnormal in 1/4 of the cases, with significant relation to the presence and intensity of periportal thickening. The hepatic artery had no significant alterations in the evaluated parameters. The splenic artery changes (increase of its diameter, peak systolic velocity and resistive index) were more frequent in the high endemicity area and in the hepatosplenic form, with significant difference between the analysed groups. CONCLUSION: Doppler US proved to be feasible and appropriate for the evaluation of the SM hemodynamic changes in field-based studies. The morbidity signs detected by ultrasound are reliable parameters of the endemicity level of SM, and the functional information of the portal system obtained by Doppler US, contributes to a more accurate diagnosis of clinical forms of the disease in endemic areas
309

Dopplervelocimetria renal em gatos Persas: valores de referência / Renal dopplervelocimetry in Persian cats: normal parameters

Cibele Figueira Carvalho 15 October 2009 (has links)
As afecções renais são frequentes em pequenos animais, especialmente em gatos. O ultrassom Doppler é uma técnica complementar à metodologia convencional com diversas aplicações na avaliação do sistema urinário. A literatura veterinária apresenta uma grande lacuna em relação a estudos determinando os parâmetros de normalidade e suas variações. Este estudo teve como objetivos determinar valores dopplervelocimétricos de referência na avaliação renal em gatos. Foi realizado um estudo prospectivo com 50 unidades renais de gatos adultos jovens da raça Persa, as quais foram examinadas ao ultrassom Doppler, sendo 13 fêmeas e 12 machos com idade entre 12 e 60 meses. Os animais foram selecionados como hígidos, através de exames laboratoriais, pressão arterial sistólica e ultrassonografia modo-B. Mensurou-se o calibre da aorta (AO) e das artérias renais (AR). Determinaram-se os parâmetros dopplervelocimétricos normais para as artérias renais e interlobares (AI) em cada animal: velocidade de pico sistólico (VPS), aceleração sistólica inicial (ASi) e os índices de resistividade (IR). Para a AO obteve-se VPS 53,17 ± 13,46 cm/s e média de diâmetro de 0,38 ± 0,04 cm. A média do diâmetro da AR foi de 0,15 ± 0,02 cm. Não foram observadas diferenças estatisticamente significantes nos dados obtidos nas AR e AI entre os lados e entre si. Considerando-se ambas as AR obteve-se a média de VPS 41,17 ± 9,40 cm/s, ASi 1,12 ± 1,14 m/s2 e IR 0,53 ± 0,07. Correlacionando-se os valores de VPS entre AR e AO obteve-se um índice de relação renal/ aorta com média de 0,82 ± 0,30 e um valor normal máximo de 1,52. Nas AI obteve-se VPS 31 ± 9 cm/s e IR 0,52 ± 0,07. Correlacionandose os valores de VPS entre AR e AI obteve-se um índice de relação renal/interlobar com um valor máximo de 3,5. Foram estabelecidos parâmetros dopplervelocimétricos normais do rim em gatos Persa e um índice renal/aórtico e renal/interlobar semelhante ao utilizado em humanos para monitorar alterações hemodinâmicas renais. Estes resultados podem balizar o início de outros estudos para determinar se a idade e outras condições clínicas ocasionam efeito nestes valores / Renal diseases are usual in small animals, especially in cats. Doppler ultrasound is a complementary tool for conventional method with several indications evaluates urinary system. There are few articles in veterinary literature studying normal parameters. This study has a goal to determine dopplervelocimetrics values for renal evaluation. Prospective study was made performing Doppler ultrasound exams of fifty renal units of adult Persian cats. The animals were classified as healthy by means of laboratorial exams, measurement of arterial systolic pressure and B-mode ultrasonography. Aortic (AA) and renal (RA) arteries diameters were measured. Normal Doppler velocimetric parameters were evaluated for renal and interlobar arteries (IA) of each animal: maximal systolic blood flow velocity (MSV), initial systolic acceleration of blood flow (ISA) and resistivity index (RI). Renal arterial diameter was 0.15 ± 0.02 cm. It was calculated aorta VPS 53.17 ± 13.46 cm/s and diameter of 0.38 ± 0.04 cm. It was not observed any statistical significant difference between the sides or arteries themselves. Considering both renal arteries it was calculated MSV 41.17 ± 9.40 cm/s, ISA 1.12 ± 1.14 m/s2 and RI 0.54 ± 0.07. Correlation of velocities of renal artery and aorta resulted in a renal/aortic ratio of 0.82 ± 0.30 and with 1.52 as maximal normal value. It was calculated for all interlobar arteries MSV 31 ± 9 cm/s and RI 0.52 ± 0.07. Correlation of velocities of renal and interlobar arteries resulted in a renal/interlobar ratio with 3.5 as maximal normal value. Normal dopplervelocimetric parameters of renal vasculature and an index renal-aortic ratio and renal-interlobar ratio were established in Persian cats similar as used in humans to monitorizing renal hemodynamic changes. These results may provide the starting of further studies to determine if age and others clinical conditions have an effect on these values
310

Usabilidade aplicada ao design ergonômico de transdutores de ultra-sonografia: uma proposta metodológica para avaliação e análise do produto.

Paschoarelli, Luis Carlos 01 January 2003 (has links)
Made available in DSpace on 2016-06-02T19:50:01Z (GMT). No. of bitstreams: 1 TeseLCP.pdf: 9583238 bytes, checksum: c2137a635f05713171b01b2d0f229f21 (MD5) Previous issue date: 2003-01-01 / The usability is one of the main aspects of the performance and quality of the interface hand/instruments whose applicability is based on methodologies of ergonomic design. In spite of the technological evolution, some hand instruments still do not attend the criteria of usability and may generate ergonomic problems in users. An example of it is the transductor employed in breast ultrasonography (US) occupational activities, which requires large biomechanical efforts. This study aimed at proposing a method of assessment and analysis based on subjective and physiological records during the application of criteria of usability in the ergonomic redesign of the transductor for US breast examinations. In order to conductthe physiological records, a Biometrics electrogoniometer was used for the analysis of wrist movements, and FSRs sensors were used for the analysis of palmar pressure. As for the subjective assesments, graphic scales of perception were applied. The collection of data occurred in experimental phases: First Experimentation assessment of wrist postures during the simulation of activity with two commercial types of transductors (n= 18); Ergonomic design application of the criteria of usability in the redesign and prepraration of the mock-up; Second Experimentation assessment of the postures and points of palmar pressure during the simulation of activity with the new mock-up and the commercial transductors (n = 10); Ergonomic design/project revision revision of the criteria of usability and development of two new mock-ups; Third experimentation assessment of the postures and points of palmar pressure during the simulation of activity with the new mock-ups and the commercial transductors (n = 10); Fourth experimentation subjective assessment of all the transductors (n = 11). The results of the first experimentation indicated high median and maximal amplitudes. The ergonomic design turned up into mock-up 01. The results of the second experimentation indicated that mock-up 01 did not present improvements in terms of wrist posture, but rather a better distribution of pressure in the palmar region. The ergonomic design/project revision turned up into two new mock-ups, 02 and 03, which presented (in the results of the third experimentation) a lower amplitude for movements and a better distribution of the percentage of time in the different pre-established ranges of amplitude, as well as in the pressure of the palmar region, mainly when mock-up 02 is concerned. Statistically meaningful differences (p < 0,05) were found only in the third experimentation, indicating that mock-ups 02 and 03 presented better performance. The results of the fourth experimentation indicated similar results from the physiological assessment, corroborating its results. Such procedures characterized a consistent alternative to the traditional methods for assessing and analyzing hand instruments in ergonomic design. / A usabilidade é um dos principais aspectos do desempenho e qualidade da interface mão/instrumentos, cuja aplicação baseia-se em metodologias de design ergonômico. Apesar da evolução tecnológica, alguns instrumentos manuais ainda não atendem aos critérios da usabilidade e podem gerar problemas ergonômicos em seus usuários. Um exemplo disso é o transdutor utilizado nas atividades ocupacionais da ultra-sonografia (US) de mama, o qual exige grandes esforços biomecânicos. Este estudo teve como objetivo propor um método de avaliação e análise, com base em registros fisiológicos e subjetivos, durante a aplicação de critérios de usabilidade no redesenho ergonômico do transdutor de US de mama. Para a realização dos registros fisiológicos, foi utilizado um eletrogoniômetro Biometrics, para análise dos movimentos do punho, e sensores FSRs para análise de pressão palmar. Para as avaliações subjetivas, foram aplicadas escalas gráficas de percepção. A coleta dos dados ocorreu em fases experimentais: Primeira experimentação - avaliação das posturas de punho durante simulação da atividade com dois modelos comerciais de transdutores (n = 18); Design ergonômico - aplicação dos critérios de usabilidade no redesenho e confecção de mock-up; Segunda experimentação - avaliação das posturas e pontos de pressão palmar, durante simulação da atividade com o novo mock-up e os transdutores comerciais (n = 10); Design ergonômico/Revisão projetual - revisão dos critérios de usabilidade e desenvolvimento de dois novos mockups; Terceira experimentação - avaliação de posturas e pontos de pressão palmar, durante simulação da atividade com os novos mock-ups e os transdutores comerciais (n= 10); Quarta experimentação - avaliação subjetiva de todos os transdutores (n = 11). Os resultados da Primeira experimentação demonstraram elevadas amplitudes médias e máximas. O Design ergonômico resultou no Mock-up 01. Os resultados da Segunda experimentação demonstraram que o Mock-up 01 não apresentou melhorias quanto a posturas de punho, mas uma melhor distribuição de pressão na região palmar. O Design ergonômico/Revisão projetual resultou em dois novos Mock-ups, 02 e 03, os quais apresentaram (nos resultados da terceira experimentação) uma menor amplitude de movimentos e uma melhor distribuição da porcentagem de tempo nas diferentes faixas de amplitude preestabelecidas, bem como da pressão na região palmar, principalmente quanto ao Mock-up 02. Diferenças estatisticamente significativas (p _ 0,05) foram encontradas somente na terceira experimentação, indicando em quais situações os Mock-up 02 e 03 apresentaram melhor desempenho. Os resultados da Quarta experimentação demonstraram o mesmo indicativo da avaliação fisiológica, corroborando seus resultados. Esses procedimentos caracterizaram um método de avaliação e análise de instrumentos manuais, expressivo e complementar para as metodologias de design ergonômico.

Page generated in 0.0445 seconds