• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 594
  • 353
  • 112
  • 61
  • 50
  • 23
  • 18
  • 9
  • 5
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • Tagged with
  • 1387
  • 613
  • 562
  • 320
  • 207
  • 167
  • 139
  • 139
  • 133
  • 133
  • 129
  • 117
  • 115
  • 109
  • 104
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
301

Análise da percepção de desconforto/conforto e antropometria em calçados femininos : uma abordagem do design ergonômico /

Valente, Eunice Lopez. January 2007 (has links)
Orientador: Luís Carlos Paschoarelli / Banca: Antônio Martiniano Fontoura / Banca: José Carlos Plácido da Silva / Resumo: O design ergonômico estuda a relação entre os usuários e a tecnologia, objetivando a melhoria das interfaces e usabilidade dos produtos. Os calçados são produtos que interagem diariamente com seres humanos e objetivam protejer e adornar (através da moda) a extremidade dos membros inferiores, cuja estrutura física e fisiológica parece ser influenciada pelo uso de calçados com salto alto e suas dimensões. Este estudo objetivou compreender como se dá a percepção de desconforto/conforto pelo público feminino e analisar as caracteristicas antropométricas das Extremidades dos Membros Inferiores (EMIs) deste público. A metodologia atendeu aos aspectos éticos; foram utilizados protocolos padronizados e equipamentos específicos (Brannock) para a medição dos pés. Os resultados da abordagem perceptiva indicaram que o desconforto está associado ao uso de calçados com saltos alto, mas o uso desse produto ainda é preferido pelas usuárias. Quanto aos aspectos antropométricos, concluiu-se que as dimensões dos pés direito e esquerdo apresentam diferenças estatisticamente significativas (p '<OU=' 0,01), reiterando a necessidade de uma melhor adequação dimensional dos calçados aos parâmetros antropométicos específicos para a população feminina brasileira / Abstract: Ergonomic design studies the relationship between users and technology, aiming to improve product interface and usability. Footwear is a product that has an influence on human beings, and its purpose, by means of fashion, is to protect and to make women's feet more beautiful, whose physical and physiological structure seems to be influenced by the use of high-heeled shoes and their dimensions. the study herein aims to understand how women perceive discomfort and comfort as well as to analyze their related to ends of the lower limbs (EMI) anthropomorphic features. Methodology used is in compliance with ethical aspects; standard protocols and specific equipment (Brannock) were used for feet measure purposes. Perception-oriented approach results indicate that discomfort is associated with the use of high-heeled shoes; nonetheless users still prefer to use them. Concerning anthropomorphic features, conclusion is that right and left foot size present significant statistical differences (p '<OU=' 0,01), reinfrocing the need to better dimensionally fit footwear to Brazilian women population anthropomorphic-related parameters / Mestre
302

Avaliação da qualidade ambiental de estabelecimentos comerciais da região central de São Carlos, SP / Environmental quality assessment of commercial establishments in the central region of São Carlos, SP

Alves, Leandro Augusto Bassi 21 June 2013 (has links)
Este estudo apresenta o diagnóstico da qualidade do ambiente interno de estabelecimentos comerciais da região central da cidade de São Carlos, localizada no interior do estado de São Paulo. Foram determinados os seguintes parâmetros: concentração mássica do material particulado em suspensão, em suas frações MP10 e MP2,5, níveis de ruído, temperatura e umidade relativa. A coleta de dados foi realizada em três locais por um período de sete horas diárias, das 10 h às 17 h. Os estabelecimentos comerciais da região central da cidade de São Carlos possuíram, em média, valores de temperatura 5,1°C maiores e de umidade relativa 35,5% menores que aqueles encontrados na estação meteorológica localizada na área rural da cidade. Foi encontrado alto coeficiente de correlação entre os dados climáticos das lojas e da estação meteorológica, indicando que o ambiente externo possui grande influência nos ambientes internos estudados. Do total dos dias amostrados, 54% foram indicados como desconfortáveis termicamente. As concentrações de MP2,5 variaram de 11,4 a 40,6 &#956g.m-3, estando acima do padrão de referência de 24 h da OMS (25 &#956g.m-3) em 35% dos dias amostrados. As concentrações de MP10 variaram de 18,4 a 85,7 &#956g.m-3, estando acima do padrão de referência de 24 h da OMS (50 &#956g.m-3) em 33% dos dias amostrados. A razão interno/externo (I/E) do material particulado foi em média de 0,82 para o MP2,5 e de 0,86 para o MP10. A concentração média das amostras de material particulado realizadas na estação seca foi 1,8 vezes maior do que das amostras realizadas na estação chuvosa para o MP10 e 1,2 vezes maior para o MP2,5. A razão MP2,5/MP10 média das amostras foi de 56%. O coeficiente de correlação entre os equipamentos utilizados para medida do material particulado foi de 0,40 para o MP2,5 e 0,53 para o MP10, sendo que as concentrações obtidas pelo equipamento contador de partículas foram em média 4,2 e 2,0 menores que as concentrações obtidas pelo equipamento gravimétrico para o MP2,5 e MP10, respectivamente. Os dados de ruído variaram de 50,6 a 67,2 dBA no ambiente interno e de 56,6 a 72,8 dBA no ambiente externo, com uma razão I/E média de 0,91. Com relação ao limite de 70 dBA estipulado pela OMS, 9% dos dias amostrados no ambiente externo ultrapassaram este valor. O ponto amostral mais ruidoso foi aquele localizado em frente à via com maior tráfego de veículos, e o menos ruidoso era localizado em frente a uma via com tráfego frequentemente congestionado. / This study presents the indoor environmental quality of stores in central São Carlos, an inner city of the state of São Paulo, in Brazil. The following parameters were monitored: mass concentration of particulate matter, in its fractions PM10 and PM2.5, noise levels, temperature and relative humidity. Data was collected in three stores in the center of town during seven hours daily, from 10 a.m. to 5 p.m. The stores had, in average, temperature values 5.1 °C higherand relative umidity 35.5% lower than those observed in a weather station located in the countryside. High correlation coefficient between the climate data in the stores and in the weather station was found, indicating that the external environment has great influence in the internal environments studied. Of all samples, 54% indicated thermal discomfort. PM2.5, mass concentrations ranged from 11.4 to 40.6 &#956g.m-3, exceeding the 24 h WHO guideline (25 &#956g.m-3) in 35% of the samples. PM10 mass concentrations ranged from 18.4 to 85.7 &#956g.m-3, exceeding the 24 h WHO guideline (50 &#956g.m-3) in 33% of the samples. The average inside/outside (I/O) ratio of the particulate matter was of 0.84 for the PM2.5 and 0.88 for the PM10. Mass concentration was 1.8 times greater in the dry season than in rainy season for the PM10, and 1.2 times greater for the PM2.5. Average PM2.5/PM10 ratio was 56%. Correlation coefficient between the gravimetric and particle counter equipments used to determine PM mass concentration was of 0.40 for the PM2.5 and 0.53 for the PM10, and latter had average means 4.2 and 2.0 times smaller, for PM2.5 and PM10, respectively. Noise levels ranged from 50.6 to 67.2 dBA in the internal environment and 56.6 to 72.8 dBA in the external environment, with an average I/O ratio of 0.91. Concerning the 70 dBA daily exposure limit estipulated by WHO, 9% of the sampled days exceeded that value. The location with higher noise pollution was located in front of the street with higher vehicle traffic, and the one with lower noise pollution was located in a street with often congested traffic.
303

Contribuição às construções em terra comprimida e compactada e influências no conforto / Contribution to compressed and compacted earth buildings and influences on comfort.

Maia, Leonardo Ribeiro 04 March 2016 (has links)
Esta dissertação buscou analisar o espaço arquitetônico contemporâneo construído com as técnicas de Taipa de Pilão (terra compactada) e Blocos de Terra Comprimida (BTC) e sua influência no conforto dos ocupantes. A utilização da terra justifica-se na possibilidade do auxílio da melhoria da qualidade das edificações e desenvolvimento de sistemas construtivos econômicos e de alto desempenho, explorando suas qualidades e vantagens. Para isso, realizou-se a revisão bibliográfica sobre o material terra e sobre as técnicas de construção que o utilizam, além de apresentar o estado da arte (últimos 15 anos) dessas técnicas e sistemas construtivos, seus processos e avaliações. O trabalho analisou os fenômenos físicos referentes à transferência de calor e umidade e as questões subjetivas que envolvem o conforto nas diversas áreas onde o conceito esteja presente (arquitetura, filosofia, história, medicina, biologia, química e psicologia). Ao final, discutiu as soluções projetuais da arquitetura de terra contemporânea e concluiu que edificações construídas com terra podem proporcionar mais do que a neutralidade (\"não desconforto\") exigida pelas normas: proporciona aos ocupantes prazer, bem-estar, expressão de seu corpo e da cultura, além de expandir e evocar sentidos, emoções e sentimentos humanos e emocionar. / Earth and Compressed Earth Blocs and their influence on users\' comfort. The earth use is justified to improve the quality of buildings and development of economic and highperformance construction systems by exploring their qualities and advantages. To reach that, this work presents a literature review about the material \"earth\" and its building techniques. In addition, it presents the state-of-the-art of this techniques and buildings systems as well their process and evaluations. Also, the work analyses the physical phenomenon of heat and humidity transfer and the subjective issues involving comfort in diverse areas that the concept could be presented (architecture, philosophy, history, medicine, biology, chemistry and psychology). Finally, it discusses the design solutions of the contemporary earth architecture. It concludes that the earth-buildings can provide more than the neutrality (\"not discomfort\"), required by the regulations. These buildings provides pleasure, well-being, expression of body and represents culture of their occupants. It evokes human senses and feelings that thrills us.
304

Resfriamento evaporativo e condicionamento de ar convencional: estudo experimental comparativo / Evaporative cooling and conventional air conditioning: a comparative experimental study

Masiero, Érico 08 November 2006 (has links)
Este trabalho visa comparar experimentalmente a técnica de resfriamento evaporativo e o condicionamento de ar convencional em relação ao índice de umidificação, à redução da temperatura interna do ar e ao consumo energético. O experimento foi realizado em três células de teste submetidas às mesmas condições climáticas, semelhantes em relação às suas características construtivas e ao volume de ar interno. Cada equipamento foi instalado em uma célula, sendo que a célula restante não contou com qualquer sistema de resfriamento, cumprindo, assim, o papel de padrão de referência do comportamento higrotérmico. A técnica de resfriamento evaporativo consiste em um dispositivo eletromecânico de ventilação forçada que insufla o ar para dentro do ambiente, fazendo-o passar por um filtro de celulose umedecido com água corrente. A ventilação forçada espalha gotículas de água no ambiente interno e o contato da água com o ar quente e seco acelera a sua evaporação. Dessa forma, o ar cede calor sensível e as gotículas de água evaporam. Como conseqüência, a temperatura diminui e a umidade do ar aumenta no interior do ambiente. O condicionador de ar convencional, constituído por evaporador, compressor e condensador, refrigera o ar por meio da compressão e da expansão do gás freon. Os dados do interior de cada célula foram automaticamente coletados por meio do Datalogger Campbell Scientific Inc CR10X. As temperaturas de bulbo seco e úmido foram regitradas com sensores termopares tipo T (Cobre-Constantan). A técnica de resfriamento evaporativo atingiu índices adequados de conforto ambiental em períodos de climas quente e seco, demonstrando, assim, ser eficaz em promover a diminuição da temperatura e a umidificação de ambientes internos. Este trabalho sugere, portanto, que a técnica de resfriamento evaporativo pode ser uma alternativa para melhorar as condições térmicas dos espaços de permanência humana com consumo de energia inferior ao do condicionador de ar convencional. / This experimental research aims to compare the evaporative cooling with the conventional air conditioning in terms of levels of humidity, reduction in indoor air temperature, and energy consume. The experiment was conducted in three purpose-built test cells, similar in structure, which were exposed to the same climatic conditions and showed the same indoor air volume rates. Each equipment was installed in one of the test cells, and the remaining cell had no cooling appliances, thus being used as reference standard. The evaporative cooling technique consists of an electrical-mechanical system of forced ventilation which introduces outdoor air into the indoor environment, across a humidifier pad made of cellulose. The forced ventilation spread small drops of water into the indoor environment and the water’s contact with the dry-warm air accelerates the evaporation process. Thus, the air loses sensible heat and the water evaporates. As a result, the air temperature decreases, and the relative humidity increases inside the environment. The conventional air conditioning system, comprises of an evaporator, a compressor and a condenser, cools the air by compressing and expanding Freon gas. The data from each cell was automatically collected by using a Datalogger CR10X. Both dry and wet bulb temperature was measured by using thermocouples type T (Copper-Constantan). The evaporative cooling technique was shown to provide higher levels of human comfort during warm-dry climate, thereby demonstrating that it can be effective in humidifying and constantly replenishing indoor air. This work therefore suggests that the evaporative cooling can be an alternative for improving the conditions of purpose-built environments with lower levels of energy consume when compared with the conventional air-conditioning systems.
305

Percepção da iluminação no espaço da arquitetura : preferências humanas em ambientes de trabalho / Perception of lighting in architectural space : preferences in work environments.

Barbosa, Cláudia Verônica Torres 24 February 2011 (has links)
As preferências humanas de iluminação nos ambientes internos estão relacionadas inicialmente à satisfação de conforto luminoso a partir de exigências não somente visuais, mas fisiológicas de saúde, conforme os objetivos do projeto e atividades. Este trabalho aborda a percepção da iluminação natural e artificial complementar diurna, em ambiente de escritório com o objetivo de identificar preferências humanas pesquisadas em um mock up, modelo que reproduz o ambiente em escala real. A partir do entendimento do ato de ver, procuramos mostrar como a luz pode alterar a percepção do espaço, revelar os contornos, alterar limites, escalas, cores e texturas das superfícies. A relação entre luz e espaço determina a nossa percepção visual do mundo que nos cerca e da maneira que o sentimos. Procuramos redefinir então o conceito de conforto visual, ampliando-o para conforto luminoso, que passaria a abordar aspectos não visuais da luz que exercem grande influência no metabolismo humano, através da regulação dos ritmos circadianos com desdobramentos na saúde, bem-estar e produtividade. Para a pesquisa experimental, o mock up foi construído simulando um ambiente de trabalho com mobiliário e objetos, onde as aberturas projetadas poderiam ser fechadas ou liberadas criando tipologias distintas de captação de luz, seja lateral e/ou zenital. Ao entrevistado, caberia escolher entre duas situações em que as variáveis consideradas foram: as posições e dimensões das aberturas para luz natural e inserção de luz artificial complementar. Para validação dos modelos e comparação dos resultados obtidos, trabalhamos com outros modelos, desde a maquete, à simulação computacional através do software Agi-32 e fotografias do ambiente em situações similares às pesquisadas no mock up. Os resultados confirmaram a hipótese de que as preferências de iluminação em escritórios estão relacionadas à satisfação do conforto luminoso em função das tarefas, incluindo aqui também a distribuição da luz, dos contrastes obtidos nas superfícies e plano de trabalho, ou distribuição harmoniosa de luminâncias. Nas situações em que a luz natural atende aos requisitos quantitativos da tarefa e conforto luminoso, ela é preferida em relação à luz artificial. A pesquisa pretende contribuir para trabalhos futuros, acerca do estudo da percepção da luz, relacionando atividade ou função do espaço, intenções do projeto, qualidade da luz arquitetural e luz tarefa. / The aim of this project is the study of people\'s preferences in interior lighting. These are initially connected to a sense of satisfaction and comfort, stemming from demands that are not only visual but also physiological. This study considers the perception of natural and complementary artificial daylight in an office environment and aims to identify preferences by means of a life size mock up model. Starting from the understanding of the act of seeing, the study seeks to show how light can change our perception of space, reveal outlines , and change limits, scale, colours and textures of surfaces. The relationship between light and space determines our visual perception of the world around us. This study seeks to redefine the concept of visual comfort, expanding it to the notion of luminous comfort. This notion comes to consider non visual aspects of light which greatly influence human metabolism by regulating our biorhythms, which in turn have ramifications for our health, well-being and productivity. In order to conduct our research a mock up was built which simulated a work environment. The space contained furniture and objects and openings could be closed or opened to create distinct types of lighting, whether lateral or zenithal. The subjects interviewed simply had to choose between tow situations. Variables considered were the aperture and position of the openings allowing in natural light and the use of complementary artificial light. To validate the models, results were compared with other models, computer simulations using Agi-32 software and photographs of the environment in similar situations as those investigated in the mock up. The results confirm the hypothesis that preferences for lighting in offices are connected to fulfilling the need for luminous comfort. Preferences are also linked to task lighting, including the distribution of light, contrast on surfaces and the work area as well as the harmonious placement of light sources. In those situations where natural light meets the quantitative demands of the lighting task luminous comfort is achieved and this is preferred to artificial light. The research contributes to future studies in how perception of light is linked to activity or the function of space. It also contributes to studies on the quality of light and task lighting.
306

(De)constructing and transforming workplace practices : feedback as an intervention

Dantsiou, Dimitra January 2017 (has links)
Little empirical work has been conducted on workplace practices in university settings. Meanwhile, the impact of feedback on changing consumption patterns has been mainly studied through individualistic approaches. The academic workplace with its variety of users offers a setting that could provide a range of insights as to how practices form and change under the impact of efficiency interventions and, in turn, how relevant policies could be formed. This research looks at workplace practices related to the regulation of indoor temperature and the use of office equipment. It examines the potential of reducing energy usage in the workplace through a case study on the understanding of and interventions in practices using consumption feedback. A framework based on social practice theory is applied where daily practices are configured by routines, technologies, knowledge and meanings. The research takes place in a UK university building, where the provision of real-time consumption feedback through a display is employed to raise energy awareness. It follows a case study approach featuring three different office typologies and associated user groups: the shared, enclosed administrative office; the PhD open-plan office, and the post-doctoral cellular office. The study begins with an examination of the thermal characteristics and comfort preferences in the case study offices. It then examines how users shape their practices in the workplace. Finally, it observes the impact of feedback through real-time displays on the reduction of energy consumption. A mixed methods approach is employed combining qualitative and quantitative data. Semi- structured interviews and on-site observations are cross-related to environmental conditions monitoring, electricity audits and thermal comfort diaries. Data collection takes place in two phases— (February 2014 and July 2014) —to capture differences in practices between the winter and summer as well as before and after the installation of real-time displays. By exploring the empirical evidence through a practice theory framework, this research shows how social dynamics, the difference between the notion of comfort at home and work, and striving for productivity can prefigure ‘passive’ thermal comfort practices in the workplace. The real-time displays did not trigger change despite the fact electricity audits revealed a savings potential related to high standby use. The inadequacy of building maintenance structures, significant installation delays and the type of projected information were the main factors restricting change. The use of a practice approach advanced the understanding as to why it is so difficult to save energy at work and use feedback as a successful intervention. The combination of qualitative enquiry and energy audits meanwhile indicated the potential source of savings.
307

Building design and environmental performance : thermal comfort through thermal mass and natural ventilation in social housing in Northeast Brazil

De Abreu Negreiros, Bianca January 2018 (has links)
Environmental consciousness leads the construction industry to greater concerns about local adaptation, less waste of resources and energy efficiency In Brazil, earth construction is a feasible approach to house building in many locations and can play a useful part in resolving the housing problems faced by that country, being already a popular approach to providing affordable housing for low income groups within the population, particularly in the Northeast Region of the country, although usually not built correctly. Although used since the colonial period, from 1500, knowledge around earth systems is not formally embedded within the Brazilian building standards and this is unhelpful in terms of promoting quality of performance of buildings thus constructed. For example, appropriate use of high thermal mass in conjunction with natural ventilation, which is frequently used in Brazil due to energy costs, can significantly influence the thermal comfort within residences, but appropriate guidance is lacking. This research considers the combined effects of earth construction and natural ventilation upon thermal comfort within social housing in Northeast Brazil. The main thesis hypothesis is that the use of thermal mass provided by earth construction combined with natural ventilation results in acceptable levels of thermal performance with respect to thermal comfort in both hot and humid and hot and dry climates. The aim is to evaluate the thermal performance of high thermal mass dwellings using adobe system combined with natural ventilation in the bioclimatic zones of Brazil's Northeast Region. The method explores thermal performance simulation using Design Builder, a graphical interface for Energy Plus program. The assessment uses parametric analysis and the adaptive thermal comfort index from de Dear and Brager (1998). The results suggest that earth construction provides a high number of comfort hours in all bioclimatic zones in Northeast Brazil and ventilation use enhances the comfort sensation.
308

Avaliação da eficiência térmica de materiais utilizados como sistemas de cobertura em instalações avícolas / Evaluation of the thermal efficiency of materials used as roofing systems in poultry houses

Ariane Cristina de Castro 16 January 2012 (has links)
O objetivo principal desta pesquisa foi avaliar a redução na carga térmica radiante e o nível de conforto térmico proporcionado pelo uso de diferentes materiais na cobertura, e diferentes forros por meio de modelos em escala reduzida e distorcida, com base nos índices ambientais de conforto térmico. A pesquisa foi realizada em duas etapas, sendo a primeira no mês de maio de 2010 e a segunda durante os meses de junho e julho de 2010. Na primeira etapa com o objetivo de avaliar a eficiência dos forros como elementos atenuadores da radiação solar foi realizado o estudo de dois tipos de telhas (cerâmica e fibrocimento) associadas a dois tipos diferentes de forro (Forro A, Forro B) e sem forro. Os forros foram instalados na parte interior do modelo em escala abaixo do telhado. Na segunda etapa, foram avaliados as telhas cerâmicas e fibrocimento, associadas ao Forro A, Forro B e a Manta Termorefletora C. A Manta termorefletora C foi alocada sobre a instalação com o objetivo de simular as condições de conforto térmico proporcionado pelo sombreamento sobre o telhado. Para avaliar o desempenho térmico dos diferentes materiais para cobertura foram registradas as variáveis meteorológicas (temperatura do ar, umidade relativa, temperatura de globo negro e velocidade do vento) e partir dessas variáveis foram calculados os índices ambientais de conforto térmico (entalpia, índice de temperatura de globo e umidade e carga térmica radiante). Foram também registradas as variações de temperatura superficiais das telhas e dos forros para a identificação da variação espacial da temperatura em diferentes horários. A primeira etapa foi composta por 6 tratamentos e a segunda etapa por 5 tratamentos. A estrutura de parcelas para as duas etapas foi o delineamento em blocos ao acaso. A análise estatística foi realizada para diferentes horários por meio da análise da variância e do teste de Tukey para a comparação múltipla das médias, visando diferenciar os tratamentos. Os resultados permitiram concluir que: dentre os tratamentos avaliados houve diferenças estatísticas entre os materiais utilizados na cobertura, e nos respectivos forros. O material de forro B foi que apresentou as maiores reduções na CTR, e nos valores de ITGU. O mapeamento térmico da temperatura de superfície dos telhados evidenciou que as menores temperaturas foram encontradas nos telhados de fibrocimento pintados de branco. E as maiores temperaturas superficiais nas telhas de cerâmica, sem pintura. O uso do sombremento de telhados em modelos em escala reduzida e distorcida não promoveu melhoria nas condições térmicas do ambiente avaliado. / The main objective of this research was to evaluate the reduction in radiant thermal load (RTL) and the level of thermal comfort provided by the use of different roofs and lining materials, through reduced and distorted scale models based on environmental indexes of thermal comfort. The research was conducted in two phases, the first in May of 2010 and the second from June to July of 2010. The first phase aimed to evaluate the efficiency of lining as an element to attenuate solar radiation. Two types of tiles (ceramic and fibrous cement) were studied associated with two different liners (linings A and B). The liners were installed under the roof inside of the scale model. The second phase evaluated ceramic and fibrous cement tiles associated with liners A and B and with the thermal reflective blanket C, which was allocated over the installation in order to simulate the thermal comfort provided by the roof shading. To the evaluation of the thermal performance of the different roofing materials, meteorological variables were recorded (air and black globe temperatures, relative humidity and wind velocity), to the posterior calculation of thermal comfort environmental indexes (enthalpy, black globe temperature and humidity index GTHI and radiant thermal load). Variations on the surface temperature of tiles and liners were also recorded to identify the spatial variation of temperature at different times of the day. The first phase consisted of 6 treatments and the second consisted of 5 treatments. A completely randomized experimental design was adopted in the two phases. The statistical analysis was performed for the different times by analysis of variance and Tukeys test of multiple comparison of means, aiming to observe differences among the treatments. The results showed a statistical difference between the materials used for roofing and lining. Liner B presented the highest reductions of RTL and GTHI values. The thermal mapping of the surface temperature of tiles showed that the lowest temperature were found in fibrous cement roofs white painted, while the highest surface temperatures were found in the unpainted ceramic tiles. The use of shading roof in reduced and distorted scale models did not improve the thermal conditions of the evaluated environment.
309

Ambiência pré-porteira: avaliação das condições bioclimáticas e das operações pré-eclosão na qualidade de pintos de corte / Post-hatching ambience: evaluation of bioclimatic conditions and of prehatching operations in the quality of one-day-old chickens

Aérica Cirqueira Nazareno 28 August 2012 (has links)
O objetivo principal foi avaliar as condições bioclimáticas, diferentes tempos de estocagem e transporte de ovos férteis oriundos de matrizes de idades diferentes, e sua influência na eclodibilidade e qualidade de pintos. O experimento foi dividido em três etapas: sala de ovos do matrizeiro, transporte e incubatório, sendo essas realizadas em três estações do ano. A primeira etapa foi desenvolvida na sala de ovos do matrizeiro avícola em Amparo SP. A avaliação bioclimática da sala de ovos foi realizada através da temperatura (T), umidade relativa (UR) e entalpia especifica (h). Foram selecionadas três diferentes idades de matrizes da linhagem Cobb Fast e três intervalos de tempos de estocagem. Selecionaram-se, 4320 ovos, porém, foram pesados aleatoriamente 140 ovos de cada tratamento na entrada e saída da sala. O delineamento experimental utilizado foi inteiramente aleatorizado com esquema fatorial 3 x 3. Na segunda etapa foi utilizado um caminhão baú. Foram transportados 4320 ovos, totalizando 18 caixas referentes às três idades das matrizes e aos três intervalos de tempos de estocagem. Os ovos foram transportados em três viagens, sendo 1440 ovos por viagem. A caracterização bioclimática dos perfis do baú deu-se a partir das variáveis (T, UR e h). Avaliaram-se dois níveis de posicionamento das caixas de ovos (superior e inferior). Também foram avaliados os níveis de vibração e choques nas estradas de terra e asfalto. Foram contabilizados os números de ovos trincados e quebrados de toda a carga. A análise da perda de água dos ovos foi realizada através dos pesos dos mesmos 140 ovos na saída da sala e na chegada ao incubatório. O delineamento experimental utilizado foi inteiramente aleatorizado com esquema fatorial 3 x 2 e a análise da geoestatistica, para (T, UR e h). Para o nível de vibração e choques foi utilizado o delineamento inteiramente aleatorizado com esquema fatorial 3 x 2 x 4 e 3 x 2. Para os ovos trincados e perda de água dos ovos, o delineamento utilizado foi inteiramente aleatorizado com esquema fatorial 3 x 3. A terceira etapa foi desenvolvida no incubatório industrial em Mogi Mirim SP. Foram realizadas as avaliações bioclimáticas na sala de ovos, incubadoras, nascedouros, sala de espera através das variaveis (T, UR e h). Foram selecionadas três diferentes idades de matrizes e 12 tempos de estocagem. Foram pesados 35 ovos individualizados de cada tratamento na entrada e saída (sala de ovo e incubadora). Após o nascimento dos pintos, foram selecionados aleatoriamente 30 pintos por tratamento para avaliar a frequência respiratória (FR), temperaturas de superfície média (TSM) e clocais (TC), e o peso. Foram determinados a eclodibilidade e taxa de eclosão dos ovos. O delineamento experimental utilizado foi hierárquico. As condições bioclimáticas, os diferentes tempos de estocagem e transporte de ovos férteis, oriundos de matrizes de idades diferentes, influenciaram a eclodibilidade e qualidade de pintos. / The major aim was to evaluate the bioclimatic conditions, different storage times and the transportation of fertile eggs from breeders of different ages, and its influence on the hatchability and quality of one-day-old chickens. The experiment was divided in three phases: the eggs room of the hatchery, transportation and hatchery, which were carried out in three seasons of the year. The first phase was developed in the eggs room of the poultry hatchery located in the city of Amparo São Paulo State, Brazil. The bioclimatic evaluation of the eggs room of the hatchery was done through the temperature (T), relative humidity (RH) and specific enthalpy (h). Three different ages of breeders from Cobb Fast strain were selected and three intervals of storage times. Four thousand and three hundred and twenty eggs were selected, but 140 eggs from each treatment were randomly weighed in the entrance and in the departure of the room. A random design was adopted in a 3 x 3 factorial design. In the second phase a box-truck was used. Four thousand and three hundred and twenty eggs were transported, totaling 18 boxes referred to the three breeders ages and the three storage times. The eggs were transported in three trips, composed by 1440 eggs in each trip. The bioclimatic characterization of trucks profiles was done through the variables (T, RH and h). Two levels of boxes positioning were evaluated (upper and lower). Levels of vibration and shocks were also evaluated in the dirt and asphalt highways. The number of cracked and broken eggs was counted of all the evaluated load. The analysis of water loss of the eggs was done through the weights of the 140 eggs in the departure of the room and in the entrance in the hatchery. A random design was adopted in a 3 x 2 x 4 and 3 x 2 factorial designs. To the cracked eggs and to the water loss a random design was adopted in a 3 x 3 factorial design. The third phase was developed in a company hatchery located in the city of Mogi Mirim São Paulo State. Bioclimatic evaluations were done in the eggs room, hatchers, hatcheries and waiting room through variables (T, RH and h). Three different age of breeders and 12 storage times were selected. Thirty five individualized eggs were weighed of each treatment in the entrance and in the departure (eggs room and hatcher). After the hatching of the one-day-old chickens, 30 chicks were randomly selected per treatment to evaluate respiration rate, mean surface and cloacal temperatures, and weight. The hatchability and the hatching rate were calculated. The experimental design adopted was hierarquical. Bioclimatic conditions, the different storage times and the transportation of fertile eggs from breeders of different ages influenced the hatchability and the quality of one-day-old chickens.
310

Eficiência da área de sombreamento artificial no bem-estar de novilhas leiteiras criadas a pasto / Artificial shadow area efficiency in milk heifers welfare in pastures

Elisabete Maria Mellace 17 June 2009 (has links)
Este estudo teve como objetivo avaliar e quantificar o efeito do sombreamento artificial proporcionado por diferentes áreas de sombra sobre a fisiologia e o comportamento de novilhas leiteiras, em ambiente de pastagens. A pesquisa foi realizada no período de fevereiro a abril de 2008. A área experimental foi dividida em 20 parcelas adjacentes com 84m² para os tratamentos 1, 2 e 3 e com 70m² para os tratamentos 4 e 5. Foram comparados a testemunha (tratamento 1, sem sombra) com 4 áreas de sombreamento por animal, tratamento 2 (com 1,5m²), tratamento 3 (3,0m²), tratamento 4 (5,0m²) e tratamento 5 (8,0m²), As dimensões dos abrigos foram 1,0m x 1,5m x 3,5m (largura, comprimento e altura) (1,5m² de sombra.animal-1), 1,5m x 2,0m x 3,5m (3,0m² de sombra.animal-1), 2,0m x 2,5m x 3,5m (5,0m² de sombra.animal-1) e 2,0m x 4,0m x 3,5m (8,0m² de sombra.animal-1), sem paredes laterais. Foram utilizadas 20 novilhas mestiças, 3/4 Jersey, ½ Holandesa e Jersey e Holandesas puras, com idade entre 12 e 25 meses e peso médio variando de 240 a 360kg, pareadas em função da uniformidade de peso e idade. As novilhas permaneciam em piquetes de Penissetum purpureum e complementação da dieta no cocho, durante a noite e após as 8:00 horas eram conduzidas para as parcelas. A Tgn foi registrada por um minidatalogger da marca LOGEN LS 8856 ALPAX. As variáveis meteorológicas foram obtidas no posto agrometeorológico da ESALQ/USP. Durante nove dias não consecutivos foram registradas FR e TS. As observações comportamentais foram realizadas em dias não consecutivos (nove dias) no período das 10:00 ás 16:00 horas pelo método focal. As condições ambientais em 66,7% do período da pesquisa foram em condição de estresse térmico para as novilhas. Os valores de FR e TS foram menores sob a maior área de sombra (P<0,05) e semelhantes entre os 1,5m², 3,5m² e 5,0m² (P>0,05). Houve correlação da Tgn com a FR e a TS. Não foram observadas alterações comportamentais entre os tratamentos, os animais ficaram sob as sombras nas horas mais quentes do dia, preferencialmente em pé, o comportamento seguiu os padrões conhecidos para bovinos. Para novilhas leiteiras a melhor área de sombreamento artificial é de 3m². / This study had as objective to evaluate and quantify the effect of artificial shading proportioned by different shadow areas under physiology and behavior of milk heifers, in pastures. Research was realized in the period from February to April, 2008. Experimental area was divided in 20 adjacent parcels with 84m2 to treatments 1, 2 and 3 and with 70m2 to treatments 4 and 5. Were compared witness (treatment 1, no shadow) with 4 shading areas per animal, treatment 2 (with 1,5 m²), treatment 3 (3,0 m²), treatment 4 (5,0 m²) and treatment 5 (8,0 m²). Shelters dimensions were 1,0m x 1,5m x 3,5m (width, length and height) (1,5m² of shade.animal-1), 1,5m x 2,0m x 3,5m (3,0m² of shade.animal-1), 2,0m x 2,5m x 3,5m (5,0m² of shade.animal-1) and 2,0m x 4,0m x 3,5m (8,0m² of shade.animal-1), without walls in the sides. Twenty crossbred heifers were used, 3/4 Jersey, ½ Holstein and pure Jersey and Holstein, with ages among 12 and 25 months and average weight varying from 240 to 360 kg, paired in function of weight and age uniformity. Heifers remained in Penissetum purpureum paddocks and had a diet complementation in the trough, during the period of night and after 8:00am they were conducted to the parcels. Tgn was registered by a minidatalogger from LOGEN LS 8856 ALPAX trend. Meteorological variables were obtained in the agrometeorological post from ESALQ/USP. During nine non consecutive days were registered FR and TS. Behavioral observations were realized in non consecutive days (nine days) in the period from 10:00am to 16:00pm by the focal method. 66,7% of environmental conditions in the period of research were in thermal stress conditions to the heifers. Values of FR and TS were minor under the major area of (P<0,05) and similar among 1,5m², 3,5m² and 5,0m² (P>0,05). There was a correlation of Tgn with FR and TS. Behavioral alterations among the treatments were not observed, animals stayed under the shadow in the hotter hours of the day, preferably on foot, behavior followed the known patters to bovine. For milk heifers the better of artificial shading area is 3m².

Page generated in 0.0502 seconds