• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 268
  • 234
  • 21
  • 16
  • 8
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • Tagged with
  • 666
  • 666
  • 225
  • 218
  • 108
  • 83
  • 81
  • 70
  • 64
  • 49
  • 48
  • 45
  • 45
  • 41
  • 38
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
371

Estudo da eletrogeração de peróxido de hidrogênio utilizando eletrodos de difusão gasosa modificados com 9,10-fenantraquinona para aplicação no tratamento de efluentes contendo os antibióticos am / Study of hydrogen peroxide electrogeneration using gas diffusion electrodes modified with 9,10-phenanthraquinone for use in the treatment of effluents containing the antibiotics amoxicillin and ampicillin

Silva, Fernando Lindo 18 May 2018 (has links)
Fármacos tem sido foco de diversas estudos e pesquisas devido à constatação de sua ocorrência em diversos compartimentos ambientais. Esses compostos, com destaque para os antibióticos, apresentam biodegradação limitada e contínua introdução nos sistemas hídricos devido ao descarte incorreto, eliminação por excreção de parte da dose ingerida e, principalmente, pelo processo de fabricação nas indústrias farmacêuticas. Como as formas convencionais de tratamento têm se mostrado pouco efetivas, a tecnologia eletroquímica associada aos processos oxidativos avançados (POA) têm se mostrado uma maneira eficiente na degradação desses compostos. Em diversos estudos, os eletrodos de difusão gasosa (EDG) são apresentados como uma opção promissora no que diz respeito à eletrogeração de peróxido de hidrogênio, uma das principais fontes de radical hidroxila utilizado nos POA. Nesse aspecto, surgem estudos sobre modificadores que podem atuar como catalisadores nesse processo. Neste trabalho estudou-se o comportamento eletroquímico de dois modificares orgânicos suportados em matriz condutora de carbono Printex 6L. Os compostos orgânicos escolhidos, pertencentes a classe das quinonas, foram a 2-terc-butil-9,10-antraquinona (TBA) e a 9,10 fenantraquinona (FQA). Os estudos foram realizados em um eletrodo de disco/anel rotatório (RRDE), depositando-se uma microcamada porosa, contendo ou não o modificador, sobre o carbono vítreo deste eletrodo. Através dos resultados de voltametria cíclica e linear pode-se avaliar a geração de peróxido de hidrogênio, que foi superior para as microcamadas com adição dos modificadores. O material com 0,5% (m/m) de FQA mostrou-se o mais eficiente entre todos, com 30% de rendimento a mais quando comparado à matriz Printex e 6% maior quando comparada a mesma quantidade de TBA na produção do peróxido. Estudou-se também a eficiência da FQA para a produção de peróxido de hidrogênio (H2O2) a partir da reação de redução do oxigênio gasoso (O2), em eletrodos de difusão gasosa (EDG). Considerando os cinco eletrodos estudados (Printex não modificado e modificado com 0,1, 0,5, 1,0 e 2,0% de FQA) foi realizada uma avaliação sobre qual eletrodo seria o mais apto a ser utilizado nos trabalhos de degradação dos fármacos. Para isso fez-se a análise da concentração de peróxido de hidrogênio eletrogerada, o consumo energético e a cinética envolvida no processo. Os resultados mostraram um aumento significativo na produção de peróxido para os eletrodos modificados com 0,5 e 1,0% de FQA. Sendo que o eletrodo sem modificação atingiu um máximo de 215 ppm de H2O2 em um potencial de -1,4 V com um consumo energético de 29 kWh kg-1 de H2O2. O eletrodo modificado com 0,5% de FQA alcançou 566 pmm de H2O2 em um potencial de -1,4 V com um consumo energético de 14 kWh kg-1 de H2O2. Estudou-se também a degradação dos antibióticos amoxicilina e ampicilina (AMX e AMP) com anodos condutores comerciais de diamante dopados com boro. A influência da densidade de corrente aplicada (15, 30 e 60 mA cm-2) para o mesmo eletrólito de suporte (3 g / L de Na2SO4) e a mesma concentração inicial de antibióticos (100 mg dm-3 cada) foi avaliada. A mineralização total dos antibióticos foi atingida. Além disso, o processo foi encontrado para ser mais eficiente na densidade de corrente de 30 mA cm-2. Os resultados demonstram a importância dos processos eletroquímicos mediados na degradação de AMX e AMP. Esta influência foi confirmada por alguns testes em que a eletrólise foi acoplada à radiação UV ou à radiação ultrassônica. O uso de radiação UV resulta em uma degradação menos eficiente, enquanto que o ultrassom melhora um pouco a taxa de mineralização quando comparado ao processo eletrolítico simples. / Drugs have been the focus of several studies and researches due to the finding of their occurrence in several environmental compartments. These compounds, especially antibiotics, present limited biodegradation and continuous introduction into water systems because of incorrect disposal, elimination by excretion of part of the ingested dose and, mainly, by the manufacturing process in the pharmaceutical industries. As conventional mode of treatment have been shown to be ineffective, electrochemical technology associated with advanced oxidative processes (POA) has been shown to be an efficient way of degradation of these compounds. In several studies, gas diffusion electrodes (EDG) are presented as a promising option with respect to hydrogen peroxide electrogeneration, one of the main sources of hydroxyl radical used in POAs. In this aspect, studies on modifiers appear that can act as catalysts in this process. In this work the electrochemical behavior of two organic modifiers supported in Printex 6L carbon matrix was studied. The organic compounds chosen, belonging to the class of quinones, were 2-tert-butyl-9,10-anthraquinone (TBA) and 9,10-phenanthraquinone (FQA). The studies were performed on a rotating disk / ring electrode (RRDE), depositing a porous micro-layer, containing or not the modifier, on the glassy carbon of this electrode. Through the results of cyclic and linear voltammetry the generation of hydrogen peroxide can be evaluated, which was superior to the micro-layers with addition of the modifiers. The material with 0.5% (w / w) of FQA was the most efficient of all, with 30% more yield when compared to the Printex matrix and 6% higher when compared to the same amount of TBA in peroxide production . It was also studied the efficiency of the FQA for the production of hydrogen peroxide (H2O2) from the reduction reaction of gaseous oxygen (O2) in gaseous diffusion electrodes (EDG). Considering the five electrodes studied (Printex not modified and modified with 0.1, 0.5, 1.0 and 2.0% of FQA) an evaluation was made on which electrode would be the most suitable to be used in the degradation works of the drugs. For that, the analysis of the hydrogen peroxide concentration, the energy consumption and the kinetics involved in the process were analyzed. The results showed a significant increase in peroxide production for electrodes modified with 0.5 and 1.0% of FQA. Since the unmodified electrode reached a maximum of 215 ppm of H2O2 at a potential of -1.4 V with an energy consumption of 29 kWh kg-1 of H2O2. The electrode modified with 0.5% of FQA reached 566 pmm of H2O2 at a potential of -1.4 V with an energetic consumption of 14 kWh kg-1 of H2O2. The degradation of antibiotics amoxicillin and ampicillin (AMX and AMP) with commercial boron-doped diamond conducting anodes was also studied. The influence of the applied current density (15, 30 and 60 mA cm-2) for the same support electrolyte (3 g / L Na2SO4) and the same initial concentration of antibiotics (100 mg dm-3 each) was evaluated. Total mineralization of antibiotics was achieved. In addition, the process was found to be more efficient at current density of 30 mA cm-2. The results demonstrate the importance of the electrochemical processes mediated in the degradation of AMX and AMP. This influence was confirmed by some tests in which the electrolysis was coupled to UV radiation or to ultrasonic radiation. The use of UV radiation results in less efficient degradation, while ultrasound improves the rate of mineralization somewhat compared to the simple electrolyte process.
372

Análise microscópica e histométrica comparativa da aplicação de uma pasta à base de metronidazol e da irrigação com iodeto de sódio e peróxido de hidrogênio para o tratamento de alvéolos dentários infectados de ratos / Microscopic and histometric comparative analysis of a metronidazole ointment application and sodium iodide plus hydrogen peroxide irrigation in the treatment of infected tooth sockets of rats

Rodrigues, Moacyr Tadeu Vicente 06 July 2007 (has links)
O processo de reparo em alvéolo infectado de ratos foi avaliado após a utilização de três tipos de tratamento: (1) curetagem e irrigação com soro fisiológico seguida do preenchimento com uma pasta à base de metronidazol a 10%, lidocaína a 2%, menta e carboximetilcelulose, (2) irrigação única com solução de iodeto de sódio a 2% e peróxido de hidrogênio a 3% na proporção 1:1 e (3) irrigação diária, por 3 dias, com solução de iodeto sódio a 2% e peróxido de hidrogênio a 3% na proporção 1:1. Foram utilizados 75 ratos que constituíram os seguintes grupos: Grupo I: alvéolo não infectado (grupo controle positivo); Grupo II: alvéolo infectado sem nenhum tratamento; Grupo III: alvéolo infectado tratado com irrigação única de solução de iodeto de sódio a 2 % e peróxido de hidrogênio a 3% na proporção 1:1; Grupo IV: alvéolo infectado tratado com irrigação diária, por 3 dias, de solução de iodeto de sódio a 2 % e peróxido de hidrogênio a 3% na proporção 1:1; Grupo V: alvéolo infectado submetido à curetagem, irrigação com soro fisiológico e preenchimento com pasta à base de metronidazol a 10% e lidocaína a 2%, carboximetilcelulose e menta. Os animais, em número de 5 em cada grupo foram sacrificados aos 6, 15 e 28 dias após a exodontia do incisivo superior e as peças obtidas analisadas em microscopia óptica. Os resultados foram submetidos à análise qualitativa e quantitativa e evidenciaram melhor reparo nos grupos tratados em relação ao grupo sem tratamento. Com base nos resultados foi possível concluir que: os grupos III, IV e V apresentaram melhores condições de reparo frente ao grupo II, porém diferentes significantemente ao grupo I; o grupo V apresentou os melhores resultados quanto à neoformação óssea nos períodos de 15 e 28 dias, sendo uma opção interessante a ser considerada para o tratamento da alveolite. / The healing process in infected tooth sockets was evaluated after application of three types of treatment.: (1) surgical cleaning of the socket with alveolar curettes, saline solution irrigation and complete filling of the socket with a 10% metronidazole, 2% lidocaine, carboxymethylcelullose and mint as flavoring, (2) Single irrigation with 2% sodium iodide and 3% hydrogen peroxide solution (1:1) and (3) Daily irrigation, for three days, with 2% sodium iodide and 3% hydrogen peroxide solution (1:1). Seventy-five rats were randomly assigned to the following groups: Group I: Non-infected tooth socket (positive control group); Group II: Infected tooth socket without treatment; Group III: Infected tooth socket treated with single irrigation of 2% sodium iodide and 3% hydrogen peroxide solution (1:1); Group IV: Infected tooth socket treated daily, for three days, with irrigation of 2% sodium iodide and 3% hydrogen peroxide solution (1:1); Group V: Infected tooth socket treated with surgical cleaning of the socket with alveolar curettes, saline solution irrigation and complete filling of the socket with a 10% metronidazole, 2% lidocaine, carboxymethylcelullose and mint as flavoring. The rats were killed in number of five at each group after 6, 15 e 28 days of superior incisor extraction. The histological findings were measured by qualitative and quantitative methods. The results demostrated better results of tooth socket healing in treated groups. Based on the results it was possible to conclude that groups III, IV and V exhibited better conditions of alveolar healing, compared to group II, although significant difference was observed with group I. Group V showed the best results in bone formation at 15 and 28 days, consisting in an interesting option for dry socket treatment.
373

Mecanismos de defesa dos mastócitos contra o periodontopatógeno Aggregatibacter actinomycetemcomitans: atividade microbicida intracelular / Defense mechanisms of mast cells against periodontopathogen Aggregatibacter actinomycetemcomitans: intracellular microbicidal activity

Lima, Heliton Gustavo de 17 July 2015 (has links)
Os mastócitos (MCs) estão presentes tanto no periodonto normal quanto inflamado, em diferentes quantidades e em vários locais. Nos últimos anos, a eficácia e a contribuição dos MCs em eliminar bactérias, através de sua atividade microbicida intracelular, estão se tornando cada vez mais reconhecidas. Assim, a partir de MCs murinos desafiados in vitro com o periodontopatógeno Aggregatibacter actinomycetemcomitans (ATCC 29523) por 3, 5, 10 e 24 horas, o presente estudo teve como objetivo investigar a capacidade microbicida intracelular de MCs, e comparar com a capacidade microbicida de macrófagos peritoneais murinos (MPs), considerados fagócitos profissionais, por meio da contagem das unidades formadoras de colônias. Além disso, avaliou-se a produção e liberação de mediadores microbicidas, óxido nítrico (NO) e peróxido de hidrogênio (H2O2), por meio do método colorimétrico de Griess e pela degradação de substratos fluorescentes, respectivamente. Para a análise estatística, foram utilizados os testes estatísticos ANOVA Fatorial seguido do teste de Tukey e teste de correlação de Pearson (p<0.05). Nossos resultados revelaram que os MCs foram capazes de eliminar eficientemente o periodontopatógeno, principalmente após 10h de desafio intracelular. Comparando-se a atividade microbicida dos dois tipos celulares, verificou-se, nos períodos de 3h e 5h de desafio, um menor percentual de colônias viáveis no interior de MPs, em comparação aos MCs. Inversamente, nos períodos de 10h e 24h, observaram-se menores valores percentuais de colônias intracelulares nos MCs em relação aos MPs. Além disso, a produção/liberação de NO bem como, em menor proporção, de H2O2 pelos MCs foram concordantes com a sua capacidade microbicida. Este é o primeiro estudo que demonstra a eficiente ação microbicida intracelular de MCs murinos contra Aggregatibacter actinomycetemcomitans, com produção e liberação de substâncias potencialmente bactericidas, e de forma mais eficaz que os macrófagos. Esses resultados sugerem a importância dessas células nos mecanismos de defesa presentes na doença periodontal induzida por placa dentobacteriana. / Mast cells (MCs) are present in both normal and inflamed periodontal tissues, in varying amounts and locations. Recently, MCs contribution in eliminating bacteria and its effectiveness, through its intracellular microbicidal activity, have been increasingly recognized. Thus, this study aimed to investigate the intracellular microbicide capacity of MCs, and compare it with the microbicide capacity of murine peritoneal macrophages (MPs), considered professional phagocytes, by counting the colony forming units. Both cell types were challenged in vitro with periodontopathogen Aggregatibacter actinomycetemcomitans (ATCC 29523) by 3, 5, 10 and 24 hours. Additionally, the production and release of microbicidal agents, nitric oxide (NO) and hydrogen peroxide (H2O2) were evaluated by means of colorimetric Griess method and by the degradation of fluorescent substrates, respectively. Statistical analysis was performed by ANOVA Factorial test followed by Tukey and Pearson\'s correlation test (p <0.05). Our results revealed that MCs are able to efficiently eliminate periodontopathogen, mainly after 10 hours of intracellular challenge. The microbicidal activity of both cell types, in 3 and 5 hours of challenge showed a lower percentage of viable colonies inside MPs, compared to MCs. Contradictorily, in 10 and 24 hours a lower percentage of intracellular colonies in MCs was observed in relation to MPs. Moreover, the production/release of NO and, in minor proportion, of H2O2 by MCs was in agreement with its microbicidal capacity. Therefore, this is the first report to describe the intracellular microicidal activity of murine MCs against Aggregatibacter actinomycetemcomitans, concerning production and release of potentially bactericidal substances, which is more effective than macrophages. These results suggest the importance of these cells in pathogenesis and defense mechanisms of biofilm-associated periodontal disease.
374

Avaliação do efeito citoprotetor do extrato bruto das folhas de Eugenia uniflora L. (Pintanga) e de compostos bioativos isolados em células secretoras de insulina

Braatz, Simoní Marinéia 22 February 2010 (has links)
Made available in DSpace on 2017-07-21T19:59:50Z (GMT). No. of bitstreams: 1 Simoni Marineia Braatz.pdf: 10395189 bytes, checksum: 4c6c59c43b05d7cdd5092ae73a0d7737 (MD5) Previous issue date: 2010-02-22 / Surinam cherry leaves are popularly used as an alternative treatment for diabetes mellitus. They are rich in phenolic compounds which have antioxidant properties. Besides, it is well known that reactive species influence in the progression of diabetes. The aim of this study was to evaluate the antioxidant, cytotoxic and cytoprotective activity of the crude leaf extracts of Eugenia uniflora L. and some major components of the extracts, quercetin (QE) and myricetin (MI); and the effect of these substances on the functionality of RINm5f cells. The methodologies performed were: Folin- Ciocalteau method, MTT reduction, DPPH method, hematoxylin-eosin stain, radioimmunoassay and Western Blot analyses. The total phenolic content obtained for the extracts was 440.27 g/mL and 37.83Yg/mL catechin equivalent/mg of aqueous extract (AE) and ethanol extract (EE), respectively. In the DPPH essay, the IC50 of AE was 321.50 g/mL, MI was 152.63 g/mL and QE was 110.278 g/mL. The EE didn’t show significant antioxidant activity. The AE and the EE are not cytotoxic in the concentrations between 12.5 - 75 g/mL and 31.25 - 500Yg/mL, respectively. QE and MI are not cytotoxic in the concentrations between 3.13 – .25 g/mL and 3.13 – 12.5 g/mL, respectively. Most of the compounds didn’t interfere in insulin secretion, except for EE, which increased at least 3 times insulin secretion and MI which decreased insulin secretion in its lower concentration tested. Hydrogen peroxide (H2O2) induced a reduction of 33% of cell viability in acute assay and 45% in chronic assay. The AE had a cytoprotective effect mainly in the chronic assay and in its higher concentrations. The EE had a similar effect only when chronically tested. QE showed a dose-dependent result (6.5 > 3.13 g/mL) in the acute assay and prevented 100% of the damage caused by H2O2 in the chronic assay. One possible cytoprotective mechanism for these compounds and extracts is the inhibition of the activation of NF-κB. Besides that, H2O2 altered intercellular adhesion with intense modification of cellular morphology. The cells presented a round shape, with the formation of folds in the membrane and reduction of cytoplasm basophily. Both extracts and isolated compounds also prevented changes in morphology caused by H2O2, suggesting prevention of lipid peroxidation. There was no variation in the expression of the proteins superoxide dismutase (SOD), Bax, disulfide isomerase (PDI) and GRP94 (glucoseregulated protein), however, the increased protein content of GRP78 was an indicative of reticular stress. These results are an evidence that Eugenia uniflora L. can be used as an alternative treatment for diabetes mellitus. / Folhas de pitanga são popularmente utilizadas no tratamento alternativo do diabetes mellitus. Portanto, o objetivo deste trabalho foi avaliar a atividade antioxidante, citotóxica e citoprotetora dos extratos brutos das folhas de Eugenia uniflora L. e de compostos encontrados nos extratos: quercetina (QE) e miricetina (MI), além do efeito destes sobre a funcionalidade de células RINm5f. As metodologias utilizadas foram: Folin-Ciocalteau, redução do MTT, captura do DPPH, coloração por hematoxilina e eosina, radioimunoensaio e Western Blot. O conteúdo total de fenóis obtido nos extratos foi 440,27 g/mL e 37,83 g/mL equivalentes de catequina/mg de extrato aquoso (EA) e alcoólico (EE), respectivamente. No ensaio de captura do DPPH, o EA apresentou um IC50 de 321,50 g/mL, a MI de 152,63 g/mL e a QE de 110,278 g/mL. O EE não apresentou significativa atividade antioxidante. O EA e o EE não apresentaram citotoxicidade nas concentrações entre 12,5 - 75 g/mL e 31,25 - 500 g/mL, respectivamente. Já a QE e MI são mais citotóxicas, apresentando viabilidade celular superior a 90% entre 3,13 - 6,25 g/mL e 3,13 - 12,5 g/mL, respectivamente. Quanto à funcionalidade celular, o EA e a QE não interferiram na secreção de insulina. A MI causou redução na secreção de insulina na concentração de 3,13 g/mL enquanto o EE aumentou mais de 3 vezes a secreção deste hormônio. O peróxido de hidrogênio (H2O2) reduziu, em média, 33% da viabilidade das células no ensaio agudo e 45% no ensaio crônico. O EA promoveu citoproteção principalmente no ensaio crônico e nas maiores concentrações testadas. Já o EE apresentou citoproteção apenas quando incubado cronicamente. A QE apresentou resultado dose-dependente (6,5 > 3,13 g/mL) no ensaio agudo e preveniu 100% dos danos causados pelo H2O2 no ensaio crônico. Um possível mecanismo de ação relacionado com a proteção dos extratos e compostos isolados é o bloqueio da ativação do NF-κB pelo H2O2. Além disso, o H2O2 alterou a adesão intercelular com intensa modificação na morfologia destas. As células apresentaram formato mais arredondado, com formação de pregas na membrana e redução da basofilia citoplasmática. Os extratos e compostos isolados preveniram alterações na morfologia causadas por H2O2, sugerindo prevenção da peroxidação lipídica. Não houve variação na concentração protéica da superóxido dismutase (SOD), BAX, dissulfito isomerase (PDI) e GRP94 (proteína regulada por glicose), entretanto houve aumetno da concentração da proteína GRP78 indicando estresse reticular. Os resultados apresentados são um indicativo de que a E. uniflora L. possa ser usada no tratamento alternativo do diabetes mellitus.
375

Efeito da tecnica de aplicação de agentes clareadores em consultório na penetração de peróxido de hidrogênio na câmara pulpar de dentes humanos / Efeito da técnica de aplicação de agentes clareadores de consultório na penetração em peróxido de hidrogênio na câmara pulpar de dentes humanos

Figueroa, Luis Alberto Balladares 18 December 2015 (has links)
Made available in DSpace on 2017-07-24T19:22:02Z (GMT). No. of bitstreams: 1 Luis Figueroa.pdf: 5025387 bytes, checksum: 9330cb3bf6d0af8254b86f433f7a5433 (MD5) Previous issue date: 2015-12-18 / This in vitro study aimed to assess the amount of hydrogen peroxide (H2O2) from different bleaching agents in the pulp chamber when subjected to different bleaching systems. Seventy-two human premolars were used and randomly divided into 12 groupsaccording to the combination of factors: bleaching agents (Opalescence Boost 38% [B] Whiteness HP Maxx 35% [WM] Total Blanc Office 35% [TBO] Whitenesse HP Blue 35% [WB] Lase Peroxide Sensy 35% [LPS] application modes (3 times 15 minutes and 1 time 45 minutes). An additional group of teeth not bleached (control) was added to the study.To assess the amount of hydrogen peroxide in the pulp chamber, all teeth were cut 3mm from the cement enamel junction, the pulp tissue removed and acetate buffer was placed in the pulp chamber. After the application of bleaching agents in accordance with the mode of application to be tested, H2O2 diffusion was measured for UV-visible spectroscopy of H2O2 by reaction with 4-amino-2,3-dimethyl-1-phenyl-3 pirazolin- 5 -one with a wavelength of 510 nm. The optical density of solution was determined and converted to micrograms of H2O2. Average data and standard deviation of the amount of H2O2 detected within the pulp chamber of the factors was significant (p < 0,0001).Overall, there was no difference between the groups when the bleaching gels tested were applied in technique 3 x 15 min (p > 0,05). However, there was significant difference when the gels were applied in technique 1 x 45 min (p < 0,05), and bleaching treatments Opalescence Boost PF 38% Whiteness HP Blue and 35% those who had the lowest values of hydrogen peroxide into the pulp. Based on the study results it is possible to conclude that the application technique for three times 15 minutes there was no difference between the tested bleaching agents, however, when applied the technique once 45 minutes, bleaching agents containing desensitizing agents are alkaline and had the lowest percentages of hydrogen peroxide within the pulp chamber. / Este estudo in vitro teve o objetivo de avaliar a quantidade de peróxido de hidrogênio (H2O2) de diferentes agentes clareadores na câmara pulpar de dentes humanos extraídos quando submetidos a diferentes sistemas clareadores. Setenta e dois prémolares humanos hígidos foram selecionados e divididos em 12 grupos de acordo com a combinação dos fatores: agentes clareadores (Opalescence Boost 38% [OB], Whitenesse HP Maxx 35% [WM], Total Blanc Office 35% [TBO], Whiteness HP Blue 35% [WB], Lase Peroxide Sensy 35% [LPS]) e modos de aplicação (3 vezes de 15 minutos e 1 vez de 45 minutos, em uma sessão). Dois grupos de dentes não clareados (controle) foram adicionados ao estudo. Para avaliar a quantidade de peróxido de hidrogênio na câmara pulpar, todos os dentes foram seccionados 3 mm da junção cemento-esmalte, o tecido pulpar foi removido e um tampão de acetato foi colocado na câmara pulpar. Após a aplicação dos agentes clareadores de acordo com o modo de aplicação a ser testado, a difusão de H2O2 foi mensurada em espectroscopia UV-visível pela reação do H2O2 com 4 –amino-2,3-dimetil-1 fenil–3 pirazolin– 5 – ona com comprimento de onda de 510 nm. A densidade óptica da solução foi determinada e convertida em microgramas de H2O2. Os dados de média e desvio-padrão da quantidade de H2O2 detectadas dentro da câmara pulpar entre os fatores foi significante (p < 0,0001). Em geral, não houve diferença entre os grupos quando os géis clareadores testados foram aplicados na técnica 3 x 15 min (p > 0,05). Contudo, houve significativa diferença quando os géis foram aplicados na técnica 1 x 45 min (p < 0,05), sendo os géis clareadores Opalescecence Boost PF 38% e Whiteness HP Blue 35% os que apresentaram os menores valores de peróxido de hidrogênio dentro da câmara pulpar.Baseado nos resultados do presente estudo é possível concluir que: na técnica de aplicação durante três vezes de 15 minutos não houve nenhuma diferença entre os agentes clareadores testados, entretanto, quando aplicados pela técnica de uma vez 45 minutos, os agentes clareadores que contem agentes dessensibilizantes e são alcalinos tiveram os menores percentuais de peróxido de hidrogênio dentro da câmara pulpar.
376

A ASSOCIAÇÃO ANALGÉSICA PARACETAMOL / CODEÍNA NÃO REDUZ A SENSIBILIDADE INDUZIDA PELO CLAREAMENTO DENTAL: ENSAIO CLÍNICO RANDOMIZADO, PARALELO, TRIPLO-CEGO / ANALGESIC ASSOCIATION ACETAMINOPHEN / CODEINE DOES NOT REDUCE BLEACHING-INDUCED TOOTH SENSITIVITY: A RANDOMIZED, PARALLEL, TRIPLE-BLIND CLINICAL TRIAL

Coppla, Fabiana Fernandes Madalozzo 28 June 2017 (has links)
Submitted by Eunice Novais (enovais@uepg.br) on 2017-08-17T19:02:15Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) FABIANA FERNANDES MADALOZZO COPPLA.pdf: 8129839 bytes, checksum: 555584401fddabd5299b0abdea4be4de (MD5) / Made available in DSpace on 2017-08-17T19:02:15Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) FABIANA FERNANDES MADALOZZO COPPLA.pdf: 8129839 bytes, checksum: 555584401fddabd5299b0abdea4be4de (MD5) Previous issue date: 2017-06-28 / Introdução: A Sensibilidade dental (SD) induzida pelo clareamento é altamente prevalente. A combinação de opioides e analgésicos não opioides pode proporcionar um melhor efeito analgésico. Objetivos: Avaliar o efeito da associação de paracetamol / codeína administrado pré e pós-operatoriamente sobre o risco e a intensidade da SD induzida pelo clareamento dental. Métodos: Realizou-se um ensaio clínico randomizado paralelo, triplo cego, com 105 pacientes saudáveis os quais receberam um placebo ou uma associação de paracetamol / codeína. A primeira dose de (paracetamol 500 mg / codeína 30 mg) ou placebo foi administrada 1 h antes do clareamento em consultório (peróxido de hidrogénio 35%) e doses extras foram administradas a cada 6 h durante 48 h. A SD foi avaliada utilizando duas escalas: 0-10 escala visual analógica VAS e uma escala de classificação numérica NRS 0-4 em diferentes períodos: durante o clareamento, 1 h até 24 h, 24 h até 48 h pós clareamento. A cor foi mensurada antes e um mês após o clareamento dental com uma escala de cores visuais Vita Classical, Vita Bleachedguide 3D-Master e espectrofotômetro Vita Easyshade (Vita Zahnfabrik). O risco absoluto de SD foi avaliado pelo teste exato de Fisher. Os dados da intensidade SD com escala NRS dos dois grupos foram comparados com os testes de Mann- Whitney e Friedman, enquanto que os dados da escala VAS foram avaliados por meio de ANOVA dois fatores de medidas repetidas. As alterações de cor entre os grupos foram comparadas utilizando teste t de Student (α = 0,05). Resultados: Não foram observadas diferenças significativas entre os grupos quanto ao risco e intensidade de SD. O risco absoluto total de SD foi de aproximadamente 96%. Uma alteração de cor de quase 5 unidades da escala de cor visual Vita Classical foi detectada em ambos os grupos, que foram estatisticamente semelhantes (p> 0,05). Conclusão: O uso da associação paracetamol / codeína pré e pós clareamento de consultório não reduz o risco e a intensidade da SD induzida pelo clareamento. Implicações clínicas: O uso de um fármaco analgésico opioide não foi capaz de prevenir SD decorrente de clareamento dental em consultório. / Background: Bleaching-induced TS is highly prevalent. The combination of Opioids and non opioids analgesics may provide a better analgesic effect. Objective: To evaluate the effect of the combination of paracetamol / codeine administered before and postoperatively on the risk and intensity of TS induced by dental whitening. Methods: A triple-blind, parallel, randomized clinical trial was conducted with 105 health patients who received either a placebo or an association of codeine/acetaminophen. The first dose of Tylex® 30 mg (acetaminophen 500 mg/codeine 30 mg) or placebo was administered 1 h before the in-office bleaching (35% hydrogen peroxide), and extra doses were administered every 6 h for 48 h. The TS was recorded using two scales: 0-10 visual analog scale and a 0-4 numeric rating scale in different periods: during bleaching, 1 h up to 24 h, 24 h up to 48 h postbleaching. The color was measured before and one month after dental bleaching with a visual shade guide Vita Classical, Vita Bleachedguide 3D-Master and spectrophotometer Vita Easyshade (Vita Zahnfabrik). The absolute risk of TS was evaluated by Fisher’s exact test. Data of TS intensity with NRS scale of the two groups were compared with Mann-Whitney and Friedman tests, while data from the VAS scale were evaluated by two-way repeated measures ANOVA. The color changes between groups were compared using a Student t-test (α = 0.05). Results: No significant differences between the groups were observed in the risk and intensity of TS. The overall absolute risk of TS was approximate 96%. A color change of nearly 5 shade guide units of the Vita Classical was detected in both groups, which were statistically similar (p > 0.05). Conclusion: The use of acetaminophen/codeine association pre and post in-office bleaching does not reduce the risk and intensity of bleaching-induced TS. Practical Implications: The use of an opioid analgesic drug was not capable to prevent TS arising from in-office dental bleaching.
377

Clareamento dental interno: efeito de diferentes sistemas na microdureza e micromorfologia superficial da dentina bovina / Effect of different bleaching systems on the microhardness and ultrastructure of bovine dentin

Laise Daniela Carrasco Guerisoli 07 January 2008 (has links)
Este estudo teve como objetivos: 01.Avaliar ex vivo o efeito de diferentes sistemas clareadores na microdureza dentinária em dentes bovinos submetidos ao clareamento dental interno. 02.Avaliar ex vivo o efeito de diferentes sistemas clareadores na morfologia superficial da dentina bovina. Fragmentos de 4 x 4mm, contendo esmalte e dentina, foram obtidos de coroas de incisivos bovinos extraídos. Os espécimes foram submetidos ao clareamento dental interno com peróxido de hidrogênio a 35% e peróxido de carbamida a 37% utilizando sistemas convencionais (Opalescence Endo® and Whiteness Super Endo®) e fotoativados (Opalescence Xtra® and Whiteness HP Maxx®). Os controles foram tratados com perborato de sódio misturado com peróxido de hidrogênio a 10% ou nenhum tratamento foi realizado. A microdureza dentinária foi mensurada antes e após os tratamentos clareadores, e os valores de dureza Knoop (KHN) foram submetidos à análise estatística (two-way ANOVA, Tukey\'s port-test). Os espécimes foram observados e fotografados sob microscópio eletrônico de varredura e avaliados com relação às alterações morfológicas da superfície da dentina. Houve uma redução significante na microdureza dentinária para todos os grupos testados quando comparados aos grupos controles. Opalescence Xtra® (-11.36 ± 8.14 KHN), Opalescence Endo® (-13.71 ± 8.02 KHN), Whiteness HP Maxx® (-15.18 ± 9.58 KHN) e Whiteness Super Endo® (-16.97 ± 6.55 KHN) foram semelhantes estatisticamente. O grupo do perborato de sódio misturado com peróxido de hidrogênio 10% (2.10 ± 8.58 KHN) e o grupo sem tratamento clareador (-2.71 ± 2.40 KHN) também foram estatisticamente semelhantes entre si. Ocorreu uma grande variação no padrão de alterações da morfologia superficial da dentina com os sistemas clareadores utilizados. Todos os produtos testados apresentaram redução significativa da microdureza dentinária, exceto o grupo de perborato de sódio misturado com peróxido de hidrogênio a 10%. Ambos, pH e oxidação do peróxido de hidrogênio apresentam o papel de alterar a estrutura da dentina durante o clareamento interno. A utilização de produtos alcalinos com um tempo reduzido de aplicação (técnicas fotoativadas) pode diminuir as alterações morfológicas na dentina. / The aim of this study was: 01. To evaluate in vitro the effect of different in-office bleaching systems on the surface morphology of bovine dentin. 02. To evaluate ex vivo the effect of different bleaching systems on the microhardness of bovine dentine. Tooth fragments measuring 4 x 4mm, containing enamel and dentin, were obtained from the crowns of extracted bovine incisors. Samples were submitted to simulated intracoronal bleaching techniques with 35% hydrogen peroxide and 37% carbamide peroxide using conventional (Opalescence Endo® and Whiteness Super Endo®) and light activated systems (Opalescence Xtra® and Whiteness HP Maxx®). Controls were treated either with sodium perborate mixed with 10% hydrogen peroxide or no bleaching agent. Dentine microhardness values were measured before and after bleaching procedures, recorded as KHN (Knoop Hardness Number), and the differences between them analyzed (two-way ANOVA, Tukey\'s port-test). The samples were observed under SEM and the recorded images were evaluated for topographic alterations. Significant reductions of dentine microhardness were observed for all treatments when compared to the control groups. Opalescence Xtra® (-11.36 ± 8.14 KHN), Opalescence Endo® (-13.71 ± 8.02 KHN), Whiteness HP Maxx® (-15.18 ± 9.58 KHN) and Whiteness Super Endo® (- 16.97 ± 6.55 KHN) presented similar differences. The walking bleach technique (2.10 ± 8.58 KHN) and the untreated groups (-2.71 ± 2.40 KHN) were statistically alike.The ultrastructural alterations of dentin observed in this study varied greatly between groups, according to the products used. Apparently, higher pH products associated to in-office techniques yielded to better maintenance of dentin ultrastructure. The in-office products tested in the present study caused a significant reduction in dentine microhardness. The walking bleach technique did not affect dentine microhardness. Both low pH and hydrogen peroxide oxidation play a role in altering the ultrastructure of dentin during internal dental bleaching. The use of alkaline products with reduced time of application (in-office techniques) may decrease such morphological alterations.
378

Avaliação da adesão dental do cimento de ionômero de vidro e resina composta em função do tratamento dentinário com agentes clareadores / Evaluate of the dental bond strength of glass-ionomer cements and composite resin in dentin treated with bleaching agents

Néspoli, Fabiana Gomes 01 October 2009 (has links)
O objetivo desse trabalho foi avaliar in vitro a diferença da força de cisalhamento da dentina quando submetida a ação de algumas substâncias utilizadas como clareadores dentais e posteriormente restaurados com cimento de ionômero de vidro e resina composta. Utilizou-se 152 terceiros molares superiores hígidos que tiveram suas superfícies palatinas desgastadas e preparadas para receber os materiais restauradores após o tratamento com os agentes clareadores.Os dentes foram divididos aleatoriamente em 12 grupos de acordo com as condições em teste a saber: G1: Soro+Resina, G2: Soro+Ionônero de vidro, G3: Perborato de Sódio+Soro+Resina, G4: Perborato de Sódio+Soro+Ionônero de vidro, G5: Perborato de Sódio+Peróxido de hidrogênio 6%+Resina, G6: Perborato de Sódio+Peróxido de hidrogênio 6%+ Ionônero de vidro, G7: Perborato de Sódio+ Peróxido de hidrogênio 35%+Resina, G8: Perborato de Sódio+Peróxido de hidrogênio 35%+ Ionônero de vidro, G9: Peróxido de hidrogênio 6%+Resina, G10: Peróxido de hidrogênio 6%+ Ionônero de vidro, G11: Peróxido de hidrogênio 35%+Resina, G12: Peróxido de hidrogênio 35%+ Ionônero de vidro.Ao término das restaurações os corpos de prova foram levados à máquina de ensaio universal (EMIC) e os resultados obtidos foram analisados através do teste de ANOVA a um critério e Tukey para comprovação de possíveis diferenças estatísticas .Por essas análises podemos concluir que os materiais restauradores tiveram um comportamento equivalente em todos os grupos e as diferenças significantes ocorreram mais por conta do agente clareador, sendo os grupos G1 e G2 aqueles que tiveram melhores resultados ao teste de adesividade, onde podese observar resultados significantes do grupo G1,em relação aos G5, G9, G10 e G11.O peróxido de hidrogênio a 6% ou 35% gerou os piores resultados de adesividade, melhorados com a associação ao perborato de sódio, revelando significância estatística do grupo G7 em relação aos grupos G9, G10 e G11. / The aim of this study was to evaluate \"in vitro the difference of shear bond strength of dentin when subjected to action of some substances used as dental bleaching and then restored with glass-ionomer cements and composite resin. We used 152 healthy third molars that had their palatal surfaces worn and ready to receive the restorative materials after treatment with bleaching agents. The teeth were randomly divided into 12 groups according to the conditions in testing are: G1: Serum + resin, G2: Serum + glass ionomer , G3: sodium perborate + Serum + Resin, G4: sodium perborate + Serum + glass ionomer , G5: sodium perborate + Hydrogen Peroxide 6% + Resin, G6: perborate of Sodium Hydrogen peroxide 6 +% + glass ionomer , G7: sodium perborate + 35% hydrogen peroxide + Resin, G8: sodium perborate + 35% hydrogen peroxide + glass ionomer, G9: Hydrogen peroxide 6% + Resin , G10: Hydrogen peroxide 6% + glass ionomer , G11: Hydrogen peroxide 35% + Resin, G12: Hydrogen peroxide 35% + glass ionomer .Finely finish the restorations of the bodies of evidence were brought to universal testing machine (EMIC) and results obtained and the results were analyzed using the Anova test and a Tukey test for evidence of possible statistical differences. For this analysis we can conclude that the restorative materials had an equivalent behavior in all groups, significant differences occurred due to the bleaching agent, and the G1 and G2 who fared better adhesion to the test, we can observe results significant in the G1, for the G5, G9, G10 and G11.The hydrogen peroxide 6% or 35% yielded the worst results of adhesiveness, enhanced with the combination of sodium perborate, showing statistical significance in the G7 the groups G9, G10 and G11.
379

Influência da pré-oxidação com ozônio e peróxido de hidrogênio no desempenho da filtração lenta em areia e carvão ativado granular / The influence of pre-oxidation with ozone and hydrogen peroxide on the performance of slow filtration with filtering medium of sand and activated granular carbon

Saavedra del Aguila, Nora Katia 06 September 2002 (has links)
A pesquisa apresenta a influência da pré-oxidação com ozônio, peróxido de hidrogênio e com ozônio associado ao peróxido de hidrogênio no desempenho da filtração lenta com meio filtrante de areia e carvão ativado granular, procedida por duas unidades de pré-tratamento em série, a pré-filtração dinâmica e a pré-filtração vertical ascendente. A unidade de filtração lenta foi bem operada com taxa de 3 m3/m 2.d, tendo sido realizadas seis carreiras de filtração. A eficiência da unidade foi avaliada em função de medições de cor, absorvância a 254 nm, carbono orgânico dissolvido, coliformes fecais, algas protozoários e metazoários. Na camada biológica predominaram as Classes Chlorophyceae, Bacillariophyceae sobre as Chrysophyceae, Cyanophyceae e Euglenophyceae. A aplicação de ozônio, peróxido de hidrogênio e ozônio associado ao peróxido de hidrogênio, afetou a maturação da camada biológica em relação à diversidade de espécies e densidade populacional de algas. As algas que colonizaram o meio filtrante, ao longo de sua profundidade, foram espécies das Classes Chlorophyceae e Bacillariophyceae. O meio filtrante apresentou, também, colonização de protozoários e rotíferos. Houve diferenças significativas na qualidade do efluente do filtro lento com relação à remoção de turbidez, cor verdadeira, cor aparente, absorvância a 254 nm e carbono orgânico dissolvido nas diferentes carreiras de filtração decorrente do uso de pré-oxidantes; o que não foi observado com relação à remoção de bactérias heterotróficas, coliformes totais e fecais. / This dissertation presents the influence of pre-oxidation with ozone, hydrogen, peroxide and ozone associated with hydrogen peroxide on the performance of slow filtration with filtering medium of sand and actived granular carbon, preceded by two pretreatment units in series, i.e., dynamic and vertical downflow prefilters. Six runs of slow filtration units were operated with a rate of 3 m3/m2.d each. The efficiency of the filtering unit was evaluated by colour determination, absorbance at 254 nm, dissolved organic carbon, total coliforms, fecal coliforms, algae, protozoa and metazoa. Chlorophyceae and Bacilllariophyceae classes predominated over Chrysophyceae, Cryptophyceae, Cyanophyeeae and Euglenophyeeae classes in the schmutzdecke. The application of ozone, hydrogen peroxide and ozone associated with hydrogen peroxide affected the schmutzdecke maturation in relation to the species diversity and population density of algae. The algae that developed in the filtering medium along its depth were species of the Chlorophyceae and Bacillariophyceae classes. The filtering medium also presented a development of protozoa and rotifers. There were significam differences in the quality of slow filter effluent in relation to turbidity removal, true colour, apparent colour, absorbance at 254 nm and dissolved organic carbon in the different filtration runs caused by the use of pre-oxidants. Such differences were not observed in the removal of heterotrophic bacteria and, total and fecal coliforms.
380

Estudo do comportamento eletroquímico de carbono Printex 6L modificado com 2-terc-butil-9,10-antraquinona e 2-etil-9,10-antraquinona para a eletrogeração de H2O2 em meio ácido / Study of the electrochemical behavior of carbon Printex 6L modified with 2-tert-butyl-9,10-anthraquinone and 2-ethyl-9,10-anthraquinone for electrogeneration of the H2O2 in acid medium

Valim, Ricardo Bertholo 21 September 2012 (has links)
Neste trabalho foi estudado o comportamento eletroquímico de materiais à base de carbono Printex 6L, sem e com a adição de compostos orgânicos da classe das quinonas (2-terc-butil-9,10-antraquinona (TBA) e 2-etil-9,10-antraquinona (EA)) para a produção de peróxido de hidrogênio (H2O2) a partir da reação de redução do oxigênio gasoso (O2). Na primeira etapa, foi utilizada a técnica de microcamada porosa depositada sobre um eletrodo de disco/anel rotatório, sendo que a partir dos resultados obtidos foram confeccionados eletrodos de difusão gasosa (EDG) para a eletrogeração de H2O2. Os melhores resultados utilizando a microcamada porosa foram para os materiais com a adição dos modificadores, sendo que o material com 1,0% (m/m) de TBA na demonstrou ser o mais eficiente na geração de peróxido de hidrogênio, apresentando eficiência 20% maior comparado ao Printex 6L sem modificador. Com o eletrodo de difusão gasosa confeccionado com o composto orgânico escolhido, na melhor porcentagem de adição mássica de modificador, obteve-se a concentração de 301 mg L-1, sendo que com o eletrodo confeccionado com Printex 6L sem modificador obteve-se a concentração de 175 mg L-1, sob as mesmas condições experimentais. A eficiência cinética também apresentou os mesmos resultados quanto à eficiência dos materiais escolhidos, sendo de 5,94 mg L-1 min-1 para o material com 1,0% de TBA, no potencial de -1,0 V (vs. ECS), e de 3,05 mg L-1 min-1 para o eletrodo de difusão gasosa sem modificador, no potencial de -0,8 V (vs. ECS). / In this work, the electrochemistry behavior of the materials prepared with Printex 6L, with and without addition of organic compounds of the class of quinones, being the compounds: 2-tert-butyl-9,10-anthraquinone (TBA) and 2-ethyl-9,10-anthraquinone (EA). These materials were used to promote the electrogeneration of hydrogen peroxide through the oxygen reduction reaction. In the first phase, it was used the technique of porous microlayer deposited on the rotating ring/disk electrode, and after has been confectioned gas diffusion electrodes (GDE). The best results using the porous microlayer were for the materials with addition of modifiers, and the material with 1.0% (m/m) of 2-terc-butyl-9,10-anthraquinone was demonstrated to be the most efficient in generating hydrogen peroxide, presenting an efficiency 20% higher when compared to Printex 6L without the modifier. The gas diffusion electrode made with the chosen organic compound, in the best massic percentage of modifier, obtained the concentration of 301 mg L-1, and the electrode made with Printex 6L without the modifier obtained the maximum concentration of 175 mg L-1, under the same experimental conditions. The kinect efficiency also demonstrated the same results regarding the efficiency of the chosen materials, which means 5.94 mg L-1 min-1 for the material with 1.0% of 2-terc-butyl-9,10-anthraquinone, in the potential of -1.0 V(vs. SCE), and 3.05 mg L-1 min-1 for the gas diffusion electrode without the modifier, in the potential of -0.8 V (vs. SCE).

Page generated in 0.1125 seconds