• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 448
  • 420
  • 44
  • 30
  • 19
  • 17
  • 10
  • 8
  • 7
  • 7
  • 7
  • 7
  • 7
  • 7
  • 7
  • Tagged with
  • 1191
  • 409
  • 213
  • 157
  • 148
  • 148
  • 143
  • 137
  • 122
  • 108
  • 99
  • 96
  • 96
  • 92
  • 89
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
381

Estudo da erupção dos dentes caninos, primeiros e segundos premolares dos lados direito e esquerdo, pelo método radiográfico

Rocha, João Carlos da [UNESP] 27 June 1995 (has links) (PDF)
Made available in DSpace on 2015-12-10T14:22:57Z (GMT). No. of bitstreams: 0 Previous issue date: 1995-06-27. Added 1 bitstream(s) on 2015-12-10T14:29:11Z : No. of bitstreams: 1 000026860.pdf: 2144269 bytes, checksum: 19d0f4d1d22e6e5601ccbbba13196e0b (MD5) / A erupção dentária é um fator que ao longo de muitos anos mereceu pesquisas para o conhecimento de suas variações. Dentre as variações, a diferença de erupção entre os lados esquerdo e direito dos arcos superior e inferior, é a que menos foi analisada detalhadamente. O autor comparou a erupção alveolar dos dentes caninos, primeiros e segundos premolares, entre os lados esquerdo e direito dos arcos superior e inferior, na faixa etária de sete a 11 anos, nos sexos masculino e feminino, pelo método radiográfico. Analisando 450 radiografias panorâmicas do arquivo da Disciplina de Radiologia do Departamento de Diagnóstico e Cirurgia da Faculdade de Odontologia do Campus de São José dos Campos - UNESP, verificou que: existe precocidade de erupção alveolar nos indivíduos do sexo feminino; a seqüência de erupção alveolar para a maxila e para a mandíbula foi - primeiro premolar, segundo premolar e canino e não existe diferença estatisticamente significante na cronologia de erupção alveolar entre os lados esquerdo e direito da maxila e da mandíbula para os dentes estudados / The tooth eruption have been studied for many years about the knowledge of its variations. From these variations the difference between the eruption of the superior and inferior archs, and also the right and left sides have been poorly analysed. The author compared the alveolar eruption of the permanents canines, first and second premolars between the right and left sides of the superior and inferior archs, from 7 and 11 years of age, in males and females, by radiographic method. By the Discipline of Radiology of the Diagnosis and surgery Departament of the School of Dentistry of São José dos Campos - UNESP, observed that: there is early eruption in female; the alveolar eruption sequence in maxillar and mandibular was: first premolar, second premolar e canino. There wasn't statiscally significant difference of the alveolar eruption between the right and left sides of maxillar and mandibular archs
382

Aplicação da análise de jarabak, no estudo da relação entre a altura total facial anterior e posterior, em pacientes portadores de má-oclusão de classe I e classe II divisão 1 de angle, por meio de radiografias cefalométricas

Becker, João Batista Macedo [UNESP] 02 July 1998 (has links) (PDF)
Made available in DSpace on 2015-12-10T14:24:11Z (GMT). No. of bitstreams: 0 Previous issue date: 1998-07-02. Added 1 bitstream(s) on 2015-12-10T14:28:12Z : No. of bitstreams: 1 000126972.pdf: 1616552 bytes, checksum: f92114a4bb4ec49c024a19f7a661ec0d (MD5) / Para predizer o sentido do crescimento facial pela Análise de Jarabak & Fizzell (1985) estudamos por meio de telerradiografias de 120 pacientes, sendo trinta do sexo masculino e trinta do sexo feminino Classe I de Angle. e trinta do sexo masculino e trinta do sexo feminino Classe II Divisão 1 de Angle, na faixa etária de seis a dez anos, dentição mista sem tratamento ortodôntico. Foi estudado a proporção entre altura facial anterior (NMe) e altura facial posterior (SGo), onde a direção de crescimento facial é determinada pela fórmula AFPx100 =% que é a proporção das alturas faciais (PAF) podendo ser reto (62% ≤ 65%), horário (58% < 62% e anti-horário ( > 65% -80%), sendo determinadas as médias, desvios padrão e a proporção da altura facial (SGo - NMc), nos pacientes do sexo masculino e feminino, segundo a classificação das má-oclusões de Angle. Quanto ao dimorfismo sexual, foi verificado se há diferenças entre os tipos de má-oclusões (Classe I e Classe II Divisão 1) segundo Angle, e o sentido de crescimento facial e a correlação de quatro medidas cefalométricas foram estudadas / ln order to predict the facial growth using Jarahak's analysis, cephalometric radiographies of 120 subjects during the mixed dentition and between 6 and 10 years of age were studied. From the total, 60 subjects (30 males and 30 females) were classified as Angle's Class I and 60 subjects (30 males and 30 females) were classified as Angle's Class II, Division 1. AIl subjects did not receive any orthodontic treatment. The proportion between anterior and posterior facial heigth (SGo-NMe) was studied, which is determined by the formula PFH x 100/ AFH = %, neither being straight (> 62% < 65), clockwise ( > 58% < 62%) and anti-clockwise ( > 65% - 80%). Mean average, standard deviation and facial height proportion (SGo - NMe) were determined for males and females according to Angle's classification of malocc!usion. Sexual dimorphism was examined with regard to different types of Angle's malocclusion and the direction of the facial growth, and the correlation of four cephalometrics measurements were analvsed
383

Determinação da qualidade da radiografia digital aplicada às soldas de gasodutos e oleodutos terrestres e marítimos

Moreira, Edson Vasques [UNESP] 03 February 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:32:50Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-02-03Bitstream added on 2014-06-13T20:44:06Z : No. of bitstreams: 1 moreira_ev_dr_guara.pdf: 5519359 bytes, checksum: 5dec7fb61c7bd9212f41a70d768c2d75 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / As necessidades das empresas de explorar petróleo e gás no Brasil em águas profundas e ultras profundas, incluindo os reservatórios do pré-sal, têm exigido um desenvolvimento de melhores produtos e recursos tecnológicos para os dutos. As características dos tubos de aço, o insumo mais importante destes dutos, são as mais afetadas pelas mudanças exigidas, pelas técnicas de fabricação e pelos controles realizados durante o processo de manufatura destes tubos. As exigências das especificações das chapas de aço utilizadas estão maiores, o processo de formação e soldagem, é afetado pela busca de melhores procedimentos. Os processos de controle da qualidade das soldas dos tubos têm buscado aumentar a sua sensibilidade, visando à detecção de descontinuidades menores das que hoje são detectadas pelos métodos tradicionais. Em termos de ensaios não destrutivos, as exigências impostas para o ensaio radiográfico estão no limite do desempenho dos atuais filmes industriais disponíveis, além do compromisso sensibilidade versus tempo de exposição ser sempre um fator importante a ser considerado na produtividade exigida para atendimento dos ciclos de produção e acompanhar a velocidade das montagens dos tubos em campo. O objetivo desta tese foi estudar e determinar a qualidade da técnica da radiografia digital em relação à radiografia convencional para inspeção de juntas soldadas de tubos utilizando os parâmetros de avaliação, tais como, resolução espacial, relação sinal ruído, sensibilidade ao contraste, níveis de tons de cinza, etc. que são aplicáveis à imagens digitais. Para a avaliação da técnica da radiografia digital foram preparados 20 corpos-de-prova de juntas soldadas, com defeitos reais em 06 espessuras diferentes, distribuídos na faixa de 4,9 a 32,3 mm. Estes corpos-de-prova foram radiografados com a técnica convencional... / The needs of the petroleum and gas industries in deepwater and ultra-deepwater oil and gas fields offshore of Brazil, including pre-salt reservoirs, are required to develop better products and technological resources for the pipelines. The characteristics of steel pipes, the most important duct of these pipelines are the most affected by the requirement changes, by manufacturing techniques and by the controls carried out during the manufacturing process of these pipes. The requirements of steel plates specifications used, forming and welding process are more restrictive and affected by seeking better procedures. The quality control processes of welds of the pipes have sought to increase its sensitivity to detect minor discontinuities in comparison with the traditional methods. In terms of non-destructive tests, the requirements for the radiographic testing are within the limit of performance of current traditional industrial films available; in addition to undertaking sensitivity versus time of exposure is always an important factor to be considered in productivity required for production cycles and following the installation speed of the tubes in the field. The goal of this thesis was to study and determine the technical quality of digital radiography in relation to conventional radiography for inspection seam weld of pipes using the evaluation parameters each as basic spatial resolution, signal noise ratio, contrast sensitivity, gray level, etc. applicable to digital image. To evaluate the digital radiography technique were prepared 20 welded seam samples with defects in 06 wall thickness, distributes in the range of 4,9 to 32,3 mm. These samples were tested with conventional and digital radiographic techniques. Two models of industrials films were used for the conventional technique, the must sensible, and in the digital technique used a DDA with 127 μm pixel size... (Complete abstract click electronic access below)
384

Avaliação das alterações dentoalveolares e esqueléticas induzidas pelo Ertty System® no tratamento da má oclusão de classe II subdivisão

Meloti, Aparecida Fernanda [UNESP] 18 March 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:23Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-03-18Bitstream added on 2014-06-13T20:24:52Z : No. of bitstreams: 1 meloti_af_dr_arafo.pdf: 1748222 bytes, checksum: 1ea6d970c95044169f8ff30279c00e26 (MD5) / O Ertty System® é um sistema intrabucal para distalizar os molares superiores. Estudos a respeito desse sistema relatam uma distalização não apenas dos molares, mas de todo o segmento lateral, pré-molares e canino, com um movimento de translação e sem necessidade de muita cooperação do paciente. O presente estudo visou avaliar as alterações dentoalveolares e esqueléticas promovidas pelo tratamento com o Ertty System®. A amostra foi composta por 27 indivíduos brasileiros, de ambos os gêneros, com idades entre 12 e 15 anos, apresentando má oclusão de Classe II subdivisão, que foram tratados ortodonticamente com o Ertty System®. Para avaliação das mudanças dentoalveolares e esqueléticas, foram utilizadas telerradiografias em normas lateral e em 45o, e radiografias submentonianas obtidas em três tempos distintos: inicial (T1); na instalação do Ertty System® ou após o alinhamento e nivelamento com aparelho ortodôntico fixo (T2); e na remoção do Ertty System® (T3). Verificou-se que o Ertty System® distaliza os primeiros molares, os pré-molares e canino em um curto período de tempo (em média, quatro meses). Os segundos molares, mesmo sem estarem envolvidos na mecânica, acompanham esse movimento. Os molares distalizados não ficam inclinados após a distalização, mas, sim, verticalizados. Durante a distalização ocorre, na arcada superior, expansão e giro mesiodistal dos molares superiores e do canino superior; e, na arcada inferior, vestibularização dos incisivos inferiores, mesialização dos primeiros molares inferiores, giro mesiodistal do molar no lado normal e giro mesiodistal do canino no lado normal, além de uma contração desses dentes no lado afetado. Além disso, houve diminuição do overjet, overbite e Wits; um giro horário do plano oclusal e um crescimento e/ou deslocamento mandibular no lado da má oclusão, que precisa ser mais... / Ertty System® is an intraoral system for maxillary molars distalization. Studies on this system report not only distalization of molars, but of the entire lateral segment, canine and premolars, with a translation movement and without demanding great patient’s cooperation. The present study aimed to evaluate dentoalveolar and skeletal changes promoted by treatment with Ertty System®. The sample was composed of 27 Brazilian subjects of both sexes, aged between 12 and 15 years, with Class II subdivision malocclusion who were orthodontically treated with Ertty System®. To evaluate the dentoalveolar and skeletal changes were used lateral, oblique (45o), and submentovertex radiographs, obtained at three different times: baseline (T1); at Ertty System® installation or after alignment and leveling with fixed orthodontic appliance (T2); and at the removal of Ertty System® (T3). It was found that the Ertty System® distalizes first molars, premolars and canine over a short period of time (on average, four months). The second molars, even without being involved in the mechanics, followed this movement. Distalized molars are not inclined after distalization, but in an upright position. During distalization occurs, in the upper arch, expansion and mesiodistal rotation of maxillary molars and maxillary canine, and, in the lower arch, buccal tipping of the mandibular incisors, mesial movement of mandibular first molars, mesiodistal rotation of molar on the normal side and mesiodistal rotation of canine on the normal side, and a contraction of these teeth on the affected side. In addition, there was a decrease of overjet, overbite and Wits, a clockwise rotation of occlusal plane and growth and/or mandibular displacement on the malocclusion side, which needs to be further clarified by future studies. According to the results obtained in this study... (Complete abstract click electronic access below)
385

Construção de fantomas homogêneos pediátricos de crãnio e tórax para otimização de imagens em radiografia computadorizada

Alves, Allan Felipe Fattori [UNESP] 31 July 2014 (has links) (PDF)
Made available in DSpace on 2015-06-17T19:34:19Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-07-31. Added 1 bitstream(s) on 2015-06-18T12:49:04Z : No. of bitstreams: 1 000831392.pdf: 1327749 bytes, checksum: c3b1aa57fef6b19f5e5e19cb0ffbcd09 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este trabalho teve como objetivo a otimização de imagens de radiografia computadorizada (CR, do inglês, computed radiography) de crânio e tórax de pacientes pediátricos entre 1 e 5 anos de idade. Para atingir esse objetivo foram desenvolvidos fantomas homogêneos pediátricos, que simularam a faixa etária em estudo, a partir de exames retrospectivos de tomografia computadorizada (CT, do inglês, computed tomography). Nesse procedimento foi utilizado um algoritmo computacional para quantificar as espessuras médias de tecidos biológicos (tecido pulmonar, adiposo, mole e ósseo) presentes nas regiões anatômicas em estudo. Essas espessuras foram convertidas em materiais simuladores (lucite e alumínio) de modo a compor os fantomas homogêneos de crânio e tórax. As incertezas relativas no processo de quantificação dos exames de crânio foram de 3,5% para tecido mole e 9,5% para tecido ósseo. Na quantificação dos exames de tórax a incerteza relativa foi de 19,4% para o tecido pulmonar, 13,0% para o tecido mole e 20,0% para o tecido ósseo. O fantoma de tórax foi construído com 7,3 cm de lucite distribuídos em 4 placas de mesma espessura (15,0 x 15,0 x 1,82) cm³ arranjadas em dois pares, separadas por um espaçamento de ar de 2,86 cm. Duas placas de alumínio de (15,0 x 15,0 x 0,13) cm³ e (150,0 x 150,0 x 1,0) mm³ foram inseridas, respetivamente, entre os pares superior e inferior de lucite. O fantoma de crânio foi construído com 11,98 cm de lucite distribuídos em cinco placas de mesma espessura (15,0 x 15,0 x 2,33) cm³. Duas placas de alumínio (15,0 x 15,0 x 0,16) cm³ e (15,0 x 15,0 x 0,12) cm³ foram inseridas, respectivamente, entre os pares superior e inferior de lucite. Os fantomas homogêneos foram utilizados no processo de otimização de imagens em sistemas CR, para calibração do feixe de raios X. No processo de calibração foram determinadas técnicas-teste (combinação kVp e mAs), que produziram índices de ... / The aim of this work was to optimize computed radiography techniques of skull and chest for pediatric patients between 1 and 5 years old. To achieve this goal, pediatric homogenous phantoms were developed from retrospective computed tomography (CT) scans. In this procedure, a computational algorithm was used to quantify the average thickness of biological tissue (lung, fat, soft and bone tissue) present on the anatomic region under study. These thicknesses were converted into simulators materials (Lucite and aluminum) to build the homogeneous phantoms of skull and chest. The relative uncertainties in the quantification process of skull examinations were 3.5% for soft tissue and 9.5% for bone tissue. In the chest examination, the relative uncertainties were 19.4% for lung tissue, 13.0% for soft tissue and 20.0% for bone tissue. The chest phantom was constructed with 7.3 cm of lucite distributed in four plates of the same thickness (15.0 x 15.0 x 1.82) cm³ arranged in two pairs, separated by a spacing of 2.86 cm of air. Two aluminum plates (15.0 x 15.0 x 0.13) cm³ and (15.0 x 15.0 x 0.10) mm³ were inserted, respectively, between the upper and lower pairs of Lucite. The skull phantom was constructed with 11.98 cm of Lucite distributed in five plates of the same thickness (15.0 x 15.0 x 2.33) cm³. Two aluminum plates (15.0 x 15.0 x 0.16) cm³ and (15.0 x 15.0 x 0.12) cm³ were inserted between the upper and lower pairs of Lucite. These homogeneous phantoms were used in the optimization process for CR systems to determine test techniques (kVp and mAs combination), which produced levels of exposure around 1.96 lgM. The test images, obtained in this process, were used in the determination of physical parameters such as the effective detective quantum efficiency (eDQE) and contrast-detail. These parameters were associated with the optimal images of skull and chest for adult patients obtained in previous studies. Optimal images obtained in ...
386

Radiografia periapical como ferramenta de predição para baixa massa óssea

Licks, Renata January 2007 (has links)
O presente estudo teve como objetivo verificar se a radiografia periapical é capaz de identificar pacientes com baixa massa óssea, combinando a análise morfológica do trabeculado ósseo e a densidade radiográfica a parâmetros clínicos. A amostra foi constituída por 60 mulheres na faixa etária acima de 40 anos e em período pós-menopausa que foram encaminhadas ao Serviço de Radiologia da Faculdade de Odontologia da UFRGS durante o ano de 2006, com indicação de radiografia periapical da região de pré-molares e/ou molares inferiores e que realizaram, no mesmo período, um exame de densitometria óssea pela técnica de absorciometria por raios X de emissão dual (DXA) nas regiões de coluna lombar e fêmur proximal. Com base nos resultados da densitometria, as pacientes foram divididas em dois grupos (normal e com perda óssea) e para cada radiografia foram obtidos os valores de densidade radiográfica e 14 variáveis morfológicas do trabeculado. As variáveis clínicas utilizadas foram idade e IMC. A análise estatística por árvores de classificação e regressão foi utilizada para testar o poder preditivo dos fatores de risco - clínicos e radiográficos - na classificação das pacientes nos grupos normal e com perda óssea. A idade e o número de pontos terminais/periferia, seguido da periferia/área trabecular, densidade radiográfica e por último o IMC foram as variáveis que melhor dividiram as pacientes em normais e com perda óssea. Esse estudo conclui que a combinação das variáveis clínicas e radiográficas obtidas por meio de radiografias periapicais é capaz de identificar pacientes com perda de massa óssea. Dessa forma, o cirurgião-dentista está apto a identificar as pacientes com risco de desenvolver osteoporose e encaminhá-las para avaliação médica. / The aim of this study was to determine whether periapical radiograph can be used to identify patients with low bone mass. This goal was accomplished by combining trabecular morphologic analysis with radiographic density measurements as well as with clinical parameters. The study subject consisted of 60 postmenopausal women over forty years of age who were conducted to the Dental Radiology Service of UFRGS School of Dentistry during the year of 2006 to take a periapical radiograph of mandibular premolar and/or molar regions. Additionally, measurements of lumbar spine and proximal femur’s bone mineral density were obtained from these patients by dual-energy X-ray absortiometry, during the same period. The subjects were classified either as normal or with low bone mass according to their bone mineral density. Radiographic density measurements and fourteen morphologic features were obtained from each dental radiograph by the use of digital image processing software. The clinical variables considered were subject´s age and bone mass index (BMI). Classification and regression tree (CART) analysis was used to test the predictive power of clinical and radiographic risk factors to classify individual in either normal or low bone mass classes. CART analysis found that the most important variables for classifying subjects were age, number or terminal points/periphery, periphery/trabecular area, radiographic density and BMI. This study showed that the combination of clinical and radiography factors can identify individuals with low bone mineral density with higher accuracy than either one of the factor taken individually. As a consequence, dentists are able to pre-screen patients with abnormally high risk for developing osteoporosis through standard routine exams and conduct these patients to further medical evaluation whenever necessary.
387

Comparação quantitativa da retração de caninos superiores utilizando dois sistemas de ancoragem

Kina, Juliana [UNESP] 27 August 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:54Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-08-27Bitstream added on 2014-06-13T20:17:28Z : No. of bitstreams: 1 kina_j_me_araca.pdf: 1193550 bytes, checksum: d217ade36af8adc9e54b137cf2f19928 (MD5) / Introdução: Para a eficiência da ancoragem, diferentes protocolos são preconizados durante a mecânica ortodôntica, principalmente quando se deseja a retração inicial do canino para o alinhamento e nivelamento anterior sem a mesialização do segmento posterior. Nesse contexto, a utilização dos minimplantes tem sido cada vez mais frequente, pois possuem características desejáveis para essa finalidade como a facilidade operacional de sua instalação, dispensa a colaboração do paciente para o desenvolvimento da mecânica ortodôntica,é favorável na estética e permite um sistema de forças mais previsível. O objetivo deste trabalho foi comparar quantitativamente por meio de telerradiografias em norma lateral e radiografias panorâmicas, a taxa de retração inicial de caninos (RIC) superiores, utilizando-se dois sistemas distintos de ancoragem. Métodos: Foram selecionados 18 pacientes, formando dois grupos aleatórios de 9 indivíduos (G1 e G2), triados para tratamento ortodôntico na UNESP - Araçatuba. Como ancoragem foi utilizado minimplantes no grupo G1 e botão de Nance no grupo G2. Para todos os pacientes foram realizadas duas telerradiografias em norma lateral (T1 e T2) e duas panorâmicas (P1 e P2). Para comparação entre as fases Início (antes do tratamento) e Após (após a retração inicial de caninos) foi utilizado o teste t pareado. Para a comparação entre os grupos de minimplante e botão de Nance foi utilizado o teste t de Student para medidas independentes. Em todos os testes foi adotado nível de significância de 5% (p<0,05). Resultados: Para a RIC no Grupo G1, obteve-se uma média de 0,63 mm/mês, enquanto para o grupo G2 a média foi de 0,56 mm/mês. Conclusões: A análise das telerradiografias em norma lateral e das radiografias panorâmicas revelou a inexistência de diferença estatisticamente significante entre os dois grupos. / Introduction: For efficiency of the anchorage, different protocols are recommended during orthodontic mechanics, especially when clinicians want to retract the initial alignment and leveling without the inclination of the posterior segment. In this context, the use of mini-implants has been frequent. For this purpose it has desirable characteristics, such as the operational facility of installation, the collaboration of the patient, exemption for the development of orthodontic mechanics, it is favorable in appearance and allows more predictable system forces. This study compared, by teleradiographs and panoramic radiographs, the initial rate of retraction of canines (ICR), using two different systems of anchoring. Methods: 18 patients were selected and divided in two random groups of 9 subjects (G1 and G2). They needed and were refered to orthodontic treatment at UNESP - Araçatuba. In G1, mini-implants were used as anchor and G2 used the Nance button appliance. Two teleradiographs (T1 and T2) and two panoramic (P1 and P2) were made for all patients. The paired T test was used for comparison between Initial (before treatment) and After (after the initial retraction of canines) phases. Student's t test for independent measures was used for comparison between groups of mini-implants and the Nance button appliance. A significance level of 5% (p <0.05) was adopted in all tests. Results: For G1, an average of 0.63 mm / month was obtained, while for G2, the average was 0.56 mm / month. Conclusions: The analysis of teleradiographs and panoramic radiographs showed the absence of statistically significant difference between the two groups.
388

Estudo do envelhecimento de um tubo de raios X por métodos não invasivos

BOTTARO, MARCIO 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:53:03Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:58:12Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
389

Implantacao e desenvolvimento da neutrongrafia no reator nuclear (IEAR-1) do Instituto de Energia Atomica

FUGA, R. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:50:38Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:02:53Z (GMT). No. of bitstreams: 1 00025.pdf: 1416886 bytes, checksum: 707fc9df397d0d3d2fb2ba9945199c80 (MD5) / Dissertacao (Mestrado) / IEA/D / Escola Politecnica, Universidade de Sao Paulo - POLI/USP
390

Efeitos do colimador na qualidade de imagem em tomografia industrial de terceira geração / Collimator effects on image quality in industrial tomography third generation

CARVALHO, DIEGO V. de S. 10 November 2014 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2014-11-10T11:06:37Z No. of bitstreams: 0 / Made available in DSpace on 2014-11-10T11:06:37Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP

Page generated in 0.0346 seconds