• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 448
  • 420
  • 44
  • 30
  • 19
  • 17
  • 10
  • 8
  • 7
  • 7
  • 7
  • 7
  • 7
  • 7
  • 7
  • Tagged with
  • 1191
  • 409
  • 213
  • 157
  • 148
  • 148
  • 143
  • 137
  • 122
  • 108
  • 99
  • 96
  • 96
  • 92
  • 89
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
411

Influencia do tempo de espera, de exposição e condições de luz em imagens obtidas por placas de armazenamento de fosforo / Influence of the time and storage conditions on images acquired using phosphor storage plates

Martins, Mauro Guilherme de Barros Quirino 12 February 2005 (has links)
Orientador: Francisco Haiter Neto / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-10T08:35:13Z (GMT). No. of bitstreams: 1 Martins_MauroGuilhermedeBarrosQuirino_D.pdf: 459015 bytes, checksum: ab47f5efdd8be44f60da615d4f531069 (MD5) Previous issue date: 2005 / Resumo: O objetivo deste estudo foi verificar a influência do tempo de espera, tempo de exposição e condição de luz na qualidade final de imagens obtidas por placas de fósforo dos sistemas digitais DenOptix®, Digora® e Vistascan®. As placas foram sensibilizadas com uma escala de densidade, com a finalidade de realizar as análises objetivas, com um ¿phantom¿, constituído a partir de uma mandíbula macerada, para análise subjetiva e com dentes pré-molares, para o diagnóstico de cáries. As análises objetivas foram realizadas pelo valor do pixel dos softwares correspondentes aos sistemas digitais e estes dados, analisados estatisticamente pelos testes de Tukey e Dunnet. A análise subjetiva foi realizada por 3 radiologistas e os dados submetidos ao teste de Mann Whitney. Para o diagnóstico de cáries, foram utilizados oito avaliadores e os dados submetidos aos testes de Wilcoxom e Friedman. Como conclusões: 1. As imagens obtidas pelo sistema Digora® sofreram perda de qualidade de imagem a partir de 4 horas, após a exposição aos raios X; 2. O sistema DenOptix® apresentou-se estável quando submetido a diferentes tempos de exposição adequados e tempos de espera; 3. A qualidade da imagem das placas de armazenamento de fósforo é afetada pela qualidade dos invólucros plásticos disponíveis em cada sistema. Os invólucros do sistema Vistascan® foram capazes de proteger entrada de luz nas condições utilizadas por este estudo / Abstract: The aim of this study was to verify the influence of the delay in scanning, exposure time and light condition in the final quality of images obtained using phosphor storage plates of DenOptix®, Digora® and Vistascan® digital systems. The plates were radiographed with an aluminium step wedge for the objective analysis, with a dry mandible for the subjective analysis and with premolars teeth for caries diagnosis. The objective analysis were carried through by the pixel value obtained from the corresponding softwares of each digital systems and these data analyzed statistically by Tukey and Dunnet tests. The subjective analysis were carried through by 3 radiologists and the data submitted to Mann Whitney U test. For caries diagnosis, eight observers were used and the data submitted to Wilcoxom and Friedman tests. As conclusions: 1. The images obtained using the Digora® system showed loss of quality of image at 4 hours after exposure; 2. The DenOptix® system presented a certain stability when subjected to different delays in scanning and exposure times; 3. The quality of the image of the phosphor storage plates is affected by the quality of the available plastic hygienic bags of each system. The bags of the Vistascan® system were able to protect under all the conditions used in this study / Doutorado / Radiologia Odontologica / Doutor em Radiologia Odontológica
412

Radiografia periapical como ferramenta de predição para baixa massa óssea

Licks, Renata January 2007 (has links)
O presente estudo teve como objetivo verificar se a radiografia periapical é capaz de identificar pacientes com baixa massa óssea, combinando a análise morfológica do trabeculado ósseo e a densidade radiográfica a parâmetros clínicos. A amostra foi constituída por 60 mulheres na faixa etária acima de 40 anos e em período pós-menopausa que foram encaminhadas ao Serviço de Radiologia da Faculdade de Odontologia da UFRGS durante o ano de 2006, com indicação de radiografia periapical da região de pré-molares e/ou molares inferiores e que realizaram, no mesmo período, um exame de densitometria óssea pela técnica de absorciometria por raios X de emissão dual (DXA) nas regiões de coluna lombar e fêmur proximal. Com base nos resultados da densitometria, as pacientes foram divididas em dois grupos (normal e com perda óssea) e para cada radiografia foram obtidos os valores de densidade radiográfica e 14 variáveis morfológicas do trabeculado. As variáveis clínicas utilizadas foram idade e IMC. A análise estatística por árvores de classificação e regressão foi utilizada para testar o poder preditivo dos fatores de risco - clínicos e radiográficos - na classificação das pacientes nos grupos normal e com perda óssea. A idade e o número de pontos terminais/periferia, seguido da periferia/área trabecular, densidade radiográfica e por último o IMC foram as variáveis que melhor dividiram as pacientes em normais e com perda óssea. Esse estudo conclui que a combinação das variáveis clínicas e radiográficas obtidas por meio de radiografias periapicais é capaz de identificar pacientes com perda de massa óssea. Dessa forma, o cirurgião-dentista está apto a identificar as pacientes com risco de desenvolver osteoporose e encaminhá-las para avaliação médica. / The aim of this study was to determine whether periapical radiograph can be used to identify patients with low bone mass. This goal was accomplished by combining trabecular morphologic analysis with radiographic density measurements as well as with clinical parameters. The study subject consisted of 60 postmenopausal women over forty years of age who were conducted to the Dental Radiology Service of UFRGS School of Dentistry during the year of 2006 to take a periapical radiograph of mandibular premolar and/or molar regions. Additionally, measurements of lumbar spine and proximal femur’s bone mineral density were obtained from these patients by dual-energy X-ray absortiometry, during the same period. The subjects were classified either as normal or with low bone mass according to their bone mineral density. Radiographic density measurements and fourteen morphologic features were obtained from each dental radiograph by the use of digital image processing software. The clinical variables considered were subject´s age and bone mass index (BMI). Classification and regression tree (CART) analysis was used to test the predictive power of clinical and radiographic risk factors to classify individual in either normal or low bone mass classes. CART analysis found that the most important variables for classifying subjects were age, number or terminal points/periphery, periphery/trabecular area, radiographic density and BMI. This study showed that the combination of clinical and radiography factors can identify individuals with low bone mineral density with higher accuracy than either one of the factor taken individually. As a consequence, dentists are able to pre-screen patients with abnormally high risk for developing osteoporosis through standard routine exams and conduct these patients to further medical evaluation whenever necessary.
413

O efeito sobre as medidas cefalometricas devido à alteração da posição natural da cabeça (PNC) em telerradiografias tomadas em norma lateral

Negreiros, Paulo Eduardo 17 August 2018 (has links)
Orientador: Vânia Célia Vieira de Siqueira / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-17T06:12:45Z (GMT). No. of bitstreams: 1 Negreiros_PauloEduardo_M.pdf: 4232544 bytes, checksum: e8434e2474207fec3d2143a9d7c9541f (MD5) Previous issue date: 2000 / Resumo: Em 1884, os craniologistas adotaram o plano horizontal de Frankfurt, determinado pelos pontos Pório esquerdo, Pório direito e pelo ponto Infra-orbitário esquerdo, como sendo a referência que define a posição da cabeça enquanto paralela ao solo. Quando do surgimento da cefalometria, adotaram-se inúmeros pontos, linhas e planos de referência utilizados em craniometria, dentre os quais o plano horizontal de Frankfurt, porém somente com o desenvolvimento do cefalostato, em 1931, a validade do emprego dessas referências passou a ser questionada devido à dificuldade de localização dos pontos Pório e do Orbitário e à grande variabilidade interindividual de inclinação desse plano o que gera interpretações duvidosas nas análises cefalométricas nele baseadas. Dessa maneira a Posição Natural da Cabeça (PNC) associada a uma linha de referência extracraniana tornou-se objeto de interesse tanto para a antropologia quanto para a ortodontia por ser um posicionamento estável para as avaliações da estética facial, para o diagnóstico e para o estudo longitudinal do crescimento craniofacial. Este trabalho objetivou estudar as alterações das grandezas cefalométricas angulares e lineares mais comumente utilizadas em cefalometria, quando a posição natural da cabeça (PNC) é modificada durante a tomada da telerradiografia, sua influência no diagnóstico ortodôntico e a confiabilidade e reprodutibilidade da PNC em tomadas radiográficas sucessivas. Analisou-se 180 telerradiografias tomadas em norma lateral de 30 pacientes do sexo feminino com idade média de 21,3 anos obtidas em duas séries de tomadas radiográficas com intervalo de 15 dias entre as séries. Registrou-se em cada série, a posição natural da cabeça (PNC), a PNC acrescida de 5 graus (PNC+5°) e a PNC com flexão de 5 graus (PNC-5°) de cada paciente. Os resultados obtidos demonstraram que as grandezas lineares S-N, ENA-ENP, CO-Gn, Go-Gn, e as grandezas angulares SNA, ANB, PP.GoGn, l.PP, IMPA, 1.1, SN.VER e HF.VER não apresentaram alterações estatisticamente significantes entre as posições estudadas e entre as séries de tomadas radiográficas. As grandezas angulares SNB, SN.GoGn, FMA, SN.PP, Ângulo Z e a grandeza linear Co-Go apresentaram alterações estatisticamente significantes tanto entre as posições quanto entre séries de tomadas radiográficas, porém sem significância do ponto de vista clínico. Concluiu-se que as medidas angulares e lineares avaliadas não apresentaram alterações significantes quando a posição natural da cabeça modificou-se dentro da faixa de variação angular estudada, o que não conduziu a diagnósticos ou interpretações duvidosas. Devido a baixa variação das angulações dos ângulos SN.VER e HF.VER demonstrou-se que a metodologia empregada com a utilização da Unidade Orientadora de Posicionamento, apresentada neste trabalho, permite a reprodutibilidade da posição natural da cabeça com grande confiabilidade dentro de uma faixa de variação da PNC em ± 5°. / Abstract: Em 1884, craniologists adopted the Frankfurt horizontal plane, determined by the left Porion, right Porion and left Orbitale points, as being the reference that defines the head position while parallel to the soil. When of the appearance of the cephalometry, countless points, lines and reference planes were used in craniometry, among them the Frankfurt horizontal plane. However, only with the development of the cephalostat, in 1931, the validity of the employment of those references became questioned due to the difficulty of location of the Porion and Orbitale points and to the great variability of individual inclination of that plane which lead to doubtful interpretations when used for cephalometric analyses. Therefore, the Natural Head Position (NHP) associated with an extracranial reference line became object of so much interest for the anthropology as for the orthodontics due to a stable positioning for the evaluations of the facial aesthetics, diagnosis and for the longitudinal study of the craniofacial growth. This work aimed to study the alterations of angular and linear cephalometrics measurements more commonly used in cephalometry, when the natural head position (NHP) is modified during the taking of cephalometric radiography, its intluence in the orthodontic diagnosis, and the reliability and reproducibility of NHP for successive radiographs. One hundred and eighty cephalometrics radiographs were taken in lateral norm of 30 female patients with age range of 21,3 years old. The X-ray were obtained in two series within 15 days interval among them. In each of the series, the natural head position (NHP), the NHP added of 5 degrees (NHP+5°) and NHP with 5 degrees of flexion (NHP-5°) were registered from each patient. The obtained results demonstrated that the linear measurements S-N, ENA-ENP, CO-Gn, Go-Gn, and the angular measurements SNA, ANB, PP. GoGn, I.PP, IMP A, 1.1, SN. VER and HF. VER did not present statistically significant alterations among the studied positions and the two series of radiographic taken as well. The angular measurements of SNB, SN.GoGn, FMA, SN.PP, Z Angle and the linear measurements Co-Go presented statistically significant alterations even between the positions themselves as in the two series of radiographs taken, however, without significance on the clinical point of view. It was concluded that the angular and linear measurements appraised did not present significant alterations when the natural head position modified within of the angular variation strip studied, which did not lead to doubtful diagnosis or interpretations. Due to low variation of the angulations of the SN.VER and HF.VER angles, it was demonstrated that the methodology used with the employment of the Guiding Unit of Positioning presented in this work, allows the reproducibility of the natural head position with great reliability within at 5° variation strip of NHP. / Mestrado / Mestre em Ortodontia
414

Validade e reprodutibilidade de medidas cefalométricas derivadas da reconstrução de imagens em 2D e 3D de tomografias computadorizadas de feixe cônico / Validity and reproducibility of cephalometric measurements obtained from 2D and 3D cone beam computed tomography images reconstructed

Ramírez-Sotelo, Laura Ricardina, 1982- 17 August 2018 (has links)
Orientador: Frab Norberto Bóscolo / Dissertação (Mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba. / Made available in DSpace on 2018-08-17T21:27:03Z (GMT). No. of bitstreams: 1 Ramirez-Sotelo_LauraRicardina_M.pdf: 5567474 bytes, checksum: 98cd4142814ba81a64a557cf5eecb5ea (MD5) Previous issue date: 2011 / Resumo: A telerradiografia em norma lateral é utilizada como a ferramenta essencial e padrão da avaliação da morfologia maxilofacial. O objetivo neste trabalho foi testar a validade e a reprodutibilidade das medidas das grandezas cefalométricas angulares nas imagens 2D e 3D derivadas da reconstrução de tomografia computadorizada de feixe cônico, comparando-as com as medidas obtidas na telerradiografia convencional em norma lateral. Avaliaram-se as imagens telerradiograficas convencionais e tomográficas de 58 indivíduos. Dois examinadores, independentemente e em momentos distintos, avaliaram as telerradiografias convencionais e a média das medidas foi considerada como "padrão ouro". Outros três examinadores realizaram a avaliação das reconstruções 2D e 3D da tomografia, em dois momentos diferentes. Observou-se que todas as modalidades apresentaram diferenças significativas nas medidas das grandezas angulares exceto: na modalidade de telerradiografia virtual RaySum em 2D, para os ângulos SNB, altura facial inferior, eixo facial e cone facial; na modalidade de telerradiografia virtual em 2D de máxima intensidade, para as grandezas SNA, SNB, eixo facial, inclinação IS e cone facial; e, na modalidade de telerradiografia por cortes tomográficos em 3D, para os ângulos eixo facial, IMPA e inclinação IS em ambos os lados e para as grandezas SNA e SNB apenas no lado esquerdo. Porém, mesmo com as diferenças estatisticamente significativas encontradas, apenas o ângulo FMIA, interincisivo, inclinação IS e IMPA apresentaram diferenças absolutas entre as médias das medidas, acima dos 2° e 3°. A correlação entre as modalidades 2D e 3D, bem como entre essas com as telerradiografias convencionais foram excelentes. Concluiu-se que as medidas angulares nas imagens 2D e 3D reconstruídas da tomografia computadorizada de feixe cônico são reproduzíveis e válidas, comparando-as com as medidas obtidas na telerradiografia em norma lateral, e que mesmo que algumas tenham apresentado diferenças estatísticas significativas, elas não representam valores clínicos relevantes na avaliação cefalométrica como um todo / Abstract: The lateral cephalometric radiography is used as the standard and essential tool for assessing maxillofacial morphology. The main of this study was to test the validity and reproducibility of angular cephalometric measurements of images derived from 2D and 3D reconstruction of cone beam computed tomography, and compared them with measurements obtained in conventional lateral cephalometric radiography. Was evaluated the tomographys and conventional cephalometric images of 58 patients. Two operators, independently at different times, evaluated the conventional cephalometric radiographs and means of measurements was considered the "gold standard". Other three operators performed the evaluation of 2D and 3D reconstructions of volumetric tomography in two different times. It was observed that all modalities has significant differences in the angular measures except: in the modality of virtual radiography RaySum 2D for the SNB angle, lower facial height, facial axis and facial taper; in the modality of virtual radiography 2D maximum intensity, for the measurements SNA, SNB, facial axis, IS inclination and facial taper; in the form of radiography for 3D tomographic images for the facial axis, IMPA and IS inclination, on both sides, the angles SNA and SNB only for the left side. However, even with statistically significant differences found, only the angle FMIA, interincisal, IS inclination and IMPA showed absolute differences between the averages of above 2 ° and 3 °. The correlation between 2D and 3D, and between those with conventional radiographs were excellent. It was concluded that the angular measurements in 2D and 3D images reconstructed from cone beam computed tomography are reproducible and valid, comparing them with measurements obtained from lateral cephalometric radiography, and even though some have shown statistically significant differences, they do not represent values in the relevant clinical cephalometric evaluation as a whole / Mestrado / Radiologia Odontologica / Mestre em Radiologia Odontológica
415

Estudo do envelhecimento de um tubo de raios X por métodos não invasivos

BOTTARO, MARCIO 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:53:03Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:58:12Z (GMT). No. of bitstreams: 0 / O objetivo do presente trabalho foi a avaliação do envelhecimento de um tubo de raios X com anodo de tungstênio utilizado para aplicações de radiodiagnóstico, por meio de aplicação de cargas de acordo com distribuições de cargas de trabalho da realidade brasileira e avaliações periódicas de grandezas associadas à qualidade de radiação produzida. Para o propósito deste trabalho, um sistema clínico com retificação monofásica de onda completa foi utilizado. Para avaliação em longo prazo das características do tubo de raios X relacionadas à carga de trabalho foi necessária a medição de parâmetros que pudessem representar de forma quantitativa o envelhecimento do tubo de raios X, estando estes relacionados principalmente ao desgaste do anodo. Esta medição indireta do envelhecimento do tubo levou a escolha de quatro parâmetros, alguns deles normalmente empregados na prática de controle de qualidade de equipamentos de radiologia diagnóstica: primeira e segunda camada semi-redutora (CSR), dimensões dos pontos focais, medida não invasiva do Potencial de Pico Prático e espectrometria de raios X. Estes parâmetros foram medidos inicialmente e após cada aplicação de carga pertinente. Para garantir a confiabilidade dos resultados, condições de reprodutibilidade foram estabelecidas para cada parâmetro de avaliação. As incertezas envolvidas em todos os processos de medição foram calculadas para avaliação da real contribuição dos efeitos do envelhecimento do tubo de raios X nos parâmetros não invasivos. Dentre os parâmetros avaliados, os que mostraram maior sensibilidade aos efeitos da aplicação de carga em longo prazo foram as energias médias obtidas por meio de espectrometria de raios X e as camadas semi-redutoras. Um modelo relacionado a estes parâmetros foi aplicado e estimativas da taxa de envelhecimento do tubo de raios X para diferentes tensões de aceleração e correntes anódicas foram obtidas. / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
416

Implantacao e desenvolvimento da neutrongrafia no reator nuclear (IEAR-1) do Instituto de Energia Atomica

FUGA, R. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:50:38Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:02:53Z (GMT). No. of bitstreams: 1 00025.pdf: 1416886 bytes, checksum: 707fc9df397d0d3d2fb2ba9945199c80 (MD5) / Dissertacao (Mestrado) / IEA/D / Escola Politecnica, Universidade de Sao Paulo - POLI/USP
417

Efeitos do colimador na qualidade de imagem em tomografia industrial de terceira geração / Collimator effects on image quality in industrial tomography third generation

CARVALHO, DIEGO V. de S. 10 November 2014 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2014-11-10T11:06:37Z No. of bitstreams: 0 / Made available in DSpace on 2014-11-10T11:06:37Z (GMT). No. of bitstreams: 0 / O estudo do efeito da colimação nos detectores de radiação sobre a qualidade de imagem do tomógrafo industrial de terceira geração desenvolvido no IPEN/CNEN-SP é descrito neste trabalho. Três conjuntos de colimadores de chumbo foram projetados e confeccionados, sendo um com janelas retangulares de 2 x 5 x 50 mm e outro com 4 x 10 x 50 mm (largura x comprimento x profundidade) e um terceiro com orifício circular de 5 mm de diâmetro x 40 mm de profundidade. Os colimadores foram projetados para poderem ser facilmente substituídos entre si nos detectores de radiação. Paralelamente, foram confeccionados e utilizadas a eletrônica associada, constituída de analisadores de sinais tipo multicanal de 8 bits contendo a unidade de alta tensão e o amplificador. Dentre as vantagens deste sistema destaca-se a sua capacidade de análise multicanal rápida e possuir uma eletrônica mais simples. Valores de resolução energética comparável com a da literatura foram encontrados utilizando a eletrônica desenvolvida acoplada ao detector de radiação de NaI(Tl). Os efeitos dos colimadores foram avaliados pelas medidas tomográficas em um fantom de polimetilmetacrilato contendo componentes multifásicos estáticos (ferro, alumínio e ar). Fontes de radiação com energias de das fontes de 75Se (97 keV, 121 keV, 136 keV, 265 keV, 279 keV e 400 keV), de 137Cs (662 keV) e de 192Ir (317 keV, 468 keV e 602 keV) observou-se que a melhor imagem do fantom foi obtida com os colimadores de janelas retangulares (fendas) de 2 x 5 x 50 mm. Na avaliação dinâmica da formação de bolhas em coluna simuladora de processos industriais, a melhor imagem foi obtida com a fonte de 192Ir. / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
418

Caracterização de uma câmara de ionização ar-livre em feixes diretos de raios X utilizados em mamografia / Characterization of a free-air ionization chamber in direct X-ray beams as used in mammography

LIMA, MATEUS H. de 21 January 2015 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2015-01-21T09:58:13Z No. of bitstreams: 0 / Made available in DSpace on 2015-01-21T09:58:13Z (GMT). No. of bitstreams: 0 / Neste trabalho foram realizados testes de estabilidade e de caracterização de uma câmara de ionização de ar-livre com cilindros concêntricos da marca Victoreen, modelo 481. Os testes foram feitos utilizando feixes diretos de mamografia como uma contribuição para a implantação desta câmara como sistema padrão primário para a grandeza kerma no ar. Os testes de caracterização realizados foram: curva de saturação, eficiência de coleção de íons, efeito de polaridade, linearidade da resposta com a taxa de kerma no ar e linearidade da resposta com a variação volumétrica. O teste de eficiência de coleção de íons possibilitou a determinação do fator de correção para recombinação iônica. A maioria dos testes realizados esteve em conformidade com os limites estabelecidos por normas internacionais. Foram obtidos os fatores de correção para atenuação de fótons no ar para as qualidades de mamografia com filtros de alumínio e molibdênio. Foram determinados também os fatores de correção para transmissão e espalhamento de fótons nas bordas do diafragma para as qualidades de mamografia com filtro de alumínio e para a qualidade padrão de mamografia com filtro de molibdênio. / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
419

Correlação entre fatores de qualidade ossea mandibular e densidade ossea mineral em mulheres brasileiras / Correlation between mandibular bone quality factors and bone mineral density in brazilian women

Pedrosa, Esio Fortaleza Nascimento Chaves 13 August 2018 (has links)
Orientador: Plauto Christopher Aranha Watanabe / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-13T08:02:53Z (GMT). No. of bitstreams: 1 Pedrosa_EsioFortalezaNascimentoChaves_M.pdf: 2734521 bytes, checksum: ab04697c2441e91af05be90051625d6d (MD5) Previous issue date: 2009 / Resumo: Existem diversos métodos para avaliar a qualidade óssea através de sua densidade. Estes métodos variam no custo, disponibilidade e na dose de radiação. O cirurgião-dentista atua nos elementos dentários e nas estruturas de suporte dos maxilares e mandíbula, componentes do sistema estomatognático. Nas últimas décadas têm se pesquisado muito a respeito da qualidade óssea das estruturas de suporte dos elementos dentários, principalmente na mandíbula, com convincentes evidências de perda óssea bucal associada com a osteoporose, particularmente um aumento da porosidade cortical do osso alveolar e corpo mandibular. O Objetivo deste estudo foi avaliar a correlação de três aspectos da qualidade óssea mandibular, em radiografias panorâmicas, correlacionando-os com medidas de densidade óssea mineral (DOM) do DEXA realizados no radio, coluna e fêmur. Os resultados apresentaram correlação significante entre a classificação morfológica do córtex (CC) e a espessura da cortical basal mandibular com a DOM. Não houve correlação entre os fatores dimensão fractal (DF) e porcentagem de pixels pretos (ET) com a DOM. Pode-se concluir que é possível referenciar pacientes para o DEXA com a finalidade de pesquisar a baixa massa óssea mineral pelas análises da cortical inferior da mandíbula. / Abstract: There are several methods to evaluate the bone quality by the density. These methods vary in cost, availability and the radiation dose. The dentist works on teeth and in the maxilla and mandible support structures, components of the stomatognathic system. Recently, it has been searched too much about the bone quality of the teeth support structures, especially in the jaw with evidences of oral bone loss associated with osteoporosis, particularly an increase in cortical porosity of the alveolar bone and mandibular body. The aim of this study was to evaluate the interrelationship of three aspects of mandibular bone quality on panoramic radiographs, correlating them with measures of bone mineral density (BMD) of DEXA performed in radio, spine and femur. The results showed a significant correlation between the cortex morphological classification and cortex thickness with lower BMD. There was no correlation between the fractal dimension (FD) factors and black pixels (ET) percentage with the BMD. It could be concluded that it is possible to refer patients for DEXA in order to search for low bone mineral analysis of the lower mandibular cortex. / Mestrado / Radiologia Odontologica / Mestre em Radiologia Odontológica
420

Analise radiografica e microbiologica de canais radiculares de dentes de cães com lesão periapical antes e apos preparo quimico-mecanico / Radiographic and microbiological analysis of root canals of dogs' teeth with periapical lesions before and after chemo-mechanical preparation

Rabang, Helena Rosa Campos 13 August 2018 (has links)
Orientador: Francisco Jose de Souza Filho / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-13T16:43:23Z (GMT). No. of bitstreams: 1 Rabang_HelenaRosaCampos_D.pdf: 2819542 bytes, checksum: 75016e34f1b77318e9fd8f990bdad508 (MD5) Previous issue date: 2009 / Resumo: Os objetivos deste trabalho foram: investigar microbiologicamente, por método de cultura e pelo método do Checkerboard DNA-DNA hybridization, canais radiculares antes (C1) e após preparo químico-mecânico (C2); e, analisar radiograficamente, lesões periapicais induzidas em dentes de cães, avaliando a possível relação entre comprimento de dente e tamanho de lesão periapical. Foram utilizados 21 pré-molares inferiores de quatro cães. Os dentes foram acessados, as polpas removidas e permaneceram expostos ao meio oral por 120 dias. Após este período, as imagens das reações periapicais induzidas foram avaliadas pelo software Imagelab 2.4, mensurando área e perímetro. O preparo químico-mecânico foi procedido, sendo os dentes divididos em três diferentes grupos, de acordo com a substância química-auxiliar testada: G1- NaCl 0,09%; G2- Clorexidina 2% gel; e G3- NaOCl 5,25% + EDTA 17%. Em cada uma das amostras foi investigada a microbiota por método de Cultura que propicia crescimento de bactérias anaeróbias estritas; e, a presença de até 40 espécies bacterianas foi investigada pela técnica de Checkerboard DNA-DNA hybridization. As médias das áreas das imagens radiográficas das lesões foram de 0,06 cm2, para os segundos pré-molares, 0,12 cm2 para os terceiros pré-molares e 0,18 cm2 para os quartos pré-molares. Houve associação entre os dentes de maior comprimento com as maiores áreas de lesão periapical. Em C1 foram isoladas 60 bactérias cultiváveis, pertencendo a 32 diferentes espécies, variando de 0 a 9 espécies por canal, sendo 70% anaeróbios facultativos e 18% anaeróbios estritos, com predominio de Gram-positivos (73%). Os gêneros bacterianos mais freqüentemente isolados foram: Streptococcus, Staphylococcus, Neisseria, Propionibacterium, Actinomyces e Prevotella. Pelo Checkerboard foram detectadas 158 bactérias, pertencendo a 29 diferentes espécies, variando de 0 a 19 espécies por canal, sendo 67% anaeróbios estritos, com predomínio de Gram-negativos (67%). Os microrganismos mais frequentemente encontrados foram Campylobacter gracilis, Capnocytophaga sputigena, Leptotrichia bucallis, Prevotela intermedia, Streptococcus gordonii e Gemella morbilorum. Em C2 todos os canais apresentaram ausência de crescimento microbiano pela Cultura, porém, pelo Checkerboard foram detectadas 33 bactérias, pertencentes a 9 diferentes gêneros e 11 diferentes espécies, variando de 1 a 8 por canal, em 10 dos 21 dentes analisados. Gemella morbilorum, Capnocytophaga sputigena, Leptotrichia bucallis e Fusobacterium nucleatum sp. Polymorphum (não detectada em C1), foram detectadas com maior freqüência após o preparo químico mecânico. No G1 houve uma redução 89% de células bacterianas. A utilização de clorexidina gel 2% (G2) e do NaOCl 5,25 (G3) permitiram redução de 97% e 99%, respectivamente, não diferindo entre si, ao nível de significância de 5%. Concluíu-se que, a microbiota de canais radiculares de dentes de cães com lesão periapical induzida, por exposição ao meio oral, após 120 dias, apresenta grande número de espécies; que o preparo químico mecânico promoveu uma grande redução de microrganismos; e que os resultados sugerem existência de relação positiva entre comprimento de dente e tamanho de lesão periapical / Abstract: The objectives of this study were: to investigate, by Culture and by Checkerboard DNA-DNA hybridization, microorganisms from infected root canals before (S1) and after chemomechanical preparation (S2), and analyse radiographically induced periapical lesions in dog's teeth, for a possible relation between tooth length and lesion size. Twenty one lower premolars of four mongrel dogs were used. Their chambers were accessed and their pulps removed and left open to the oral environment for the total period of 120 days. The radiographs were evaluated by Imagelab 2.4 software to measure the area and perimeter images of the induced periapical lesions. Chemomechanical preparation was proceded, the teeth were assigned to three groups, according to the substance tested: G1- NaCl 0.09%; G2- chlorhexidine gel 2%; G3-. NaOCl 5.25% + EDTA 17%. Methodology for handling, culture and incubation for growth of strict anaerobe species was used; and, 40 bacterial species were investigated in each one of the samples by Checkerboard DNA-DNA hybridization. Measurements of the radiographic image data of the lesions were 0.06 cm2 for the second premolars, 0.12 cm2 for the third premolars and 0.18 cm2 for the fourth premolars. There was a positive association between tooth length and size of periapical lesion. In S1, a total of 60 cultivable isolates were recovered from 32 different species, ranging from 0 to 9 per canal. Facultative anaerobe species comprised 70% of the samples and 18% were strict anaerobic species with one microbiota predominantly Gram-positive (73%). The most frequent genera recovered from the canals were: Streptococcus, Staphylococcus, Neisseria, Propionibacterium, Actinomyces and Prevotella. One hundred and fifty eight bacteria were detected from 29 different species, ranging from 0 to 19 per canal. Strict anaerobe species comprised 67% of the samples with one microbiota predominantly Gram-negative (67%). The most frequent species detected by Checkerboard from the canals (S1) were: Campylobacter gracilis, Capnocitophaga sputigena, Leptotrichia bucallis, Prevotela intermedia, Streptococcus gordonii e Gemella morbilorum. In S2, no microbial growth was observed by culture. However, by checkerboard, 33 bacteria were detected, from 9 different genera and 11 differet species, ranging from 1 to 8 per canal, in 10 of the 21 investigated teeth. Gemella morbilorum, Capnocytophaga sputigena, Leptotricchia bucallis e Fusobacterium nucleatum sp. Polymorphun (not detected in S1), were detected with higher frequency after chemomechanical preparation. There was 89% of bacteria reduction in G1. Use of chlorhexidine gel 2% (G2) and NaOCl 5.25% (G3) allow bacteria reduction of 97% and 99%, respectively, with no statistical difference, with 5% significance. In conclusion, the root canal microbiota of dog teeth with induced periapical lesion, by exposure to the oral environment, after 120 days presents a great number of different species; results suggest positive relationship between the tooth length and size of the periapical lesion. / Doutorado / Endodontia / Doutor em Clínica Odontológica

Page generated in 0.047 seconds