• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 305
  • 96
  • 34
  • 21
  • 15
  • 9
  • 8
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 560
  • 560
  • 313
  • 292
  • 116
  • 83
  • 76
  • 74
  • 67
  • 66
  • 60
  • 59
  • 58
  • 58
  • 51
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
161

Índices de conforto térmico e adaptabilidade de fêmeas bubalinas em pastejo no Agreste de Pernambuco

COSTA, Lígia Alexandrina Barros da 28 February 2007 (has links)
Submitted by (edna.saturno@ufrpe.br) on 2017-04-26T15:36:43Z No. of bitstreams: 1 Ligia Alexandrina Barros da Costa.pdf: 401629 bytes, checksum: 41474d2518470019394d748cf22e8e59 (MD5) / Made available in DSpace on 2017-04-26T15:36:43Z (GMT). No. of bitstreams: 1 Ligia Alexandrina Barros da Costa.pdf: 401629 bytes, checksum: 41474d2518470019394d748cf22e8e59 (MD5) Previous issue date: 2007-02-28 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / The objectives of this work were to determine the best indexes of thermal comfort for buffaloes and to estimate the upper critical levels of these indexes, based on the physiologic parameters. The experiment was carried from february to april at agreste region of the Pernambuco state. Physiologic parameters as rectal temperature (Tr), breathing frequency (Fr) and skin temperature (Tp) were measured thrice to every week in the periods of the morning and afternoon. Sweating rate (Tsud) was measured in the afternoon, once to every week. Correlation and regression analysis were made using data obtained from ten buffaloes: five heifers and five pregnant buffaloes cows. The results showed that Fr was better than rectal temperature (Tr) and sweating rate (Tsud) as an indicator of heat stress for pregnant bufalloes cows. ITGU was better than ITU, based on Fr. Based on Tr the estimated upper critical levels of temperature-humidity index (ITU) and black globe temperature and humidity index (ITGU) were 79,5 and 89,1, respectively, for the heifers and based on breathing frequency those estimated critical levels were, respectively, 77 and 83. Based on Fr the estimated critical values of ITU and ITGU were 79 and 81, respectively, for the pregnant buffaloes cows. / O objetivo deste trabalho foi determinar os melhores índices de conforto térmico para bubalinos estimando seus valores críticos, baseando-se nos parâmetros fisiológicos. O experimento foi conduzido de fevereiro a abril na região agreste de Pernambuco. Os parâmetros fisiológicos temperatura retal (Tr), freqüência respiratória (Fr) e temperatura de pele (Tp) foram avaliados três vezes por semana nos períodos da manhã e da tarde e a taxa de sudação (Tsud) foi mensurada apenas à tarde, uma vez a cada semana. As medidas para análise de correlação entre as variáveis e regressão foram obtidas de dez animais: cinco novilhas e cinco búfalas em gestação. Os resultados obtidos evidenciaram, nas búfalas em gestação, que Fr foi o melhor indicador de estresse térmico que temperatura retal (Tr) e taxa de sudação (Tsud). O ITGU revelou ser o melhor índice que o ITU, baseando-se na Fr. Com base na Tr foram estimados valores críticos de índice de temperatura e umidade (ITU) e índice de temperatura de globo e umidade (ITGU) iguais a 79,5 e 89,1, respectivamente, para as novilhas. Baseando-se na Fr esses valores foram, respectivamente, 77 e 83. Para as búfalas, considerando a Fr, os valores críticos de ITU e ITGU foram 79 e 81, respectivamente.
162

Termografia aplicada à avaliação do ambiente térmico de alojamento e do conforto térmico de frangos de corte / Thermography applied to the evaluation of thermal environment and thermal comfort accommodation in broiler chicken

Nascimento, Guilherme Rodrigues do 18 August 2018 (has links)
Orientadores: Irenilza de Alencar Naas, Danilo Florentino Pereira / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Agrícola / Made available in DSpace on 2018-08-18T04:22:00Z (GMT). No. of bitstreams: 1 Nascimento_GuilhermeRodriguesdo_M.pdf: 1366852 bytes, checksum: 3be5b6e8ff020347c7de825f27df3e9e (MD5) Previous issue date: 2011 / Resumo: A produção de frangos de corte tem grande destaque na economia brasileira, sendo o país o terceiro maior produtor mundial e o principal exportador de carne de frangos. Um dos entraves da atividade é o estresse térmico ambiental, que impacta negativamente a produção. A pesquisa sugere que as temperaturas superficiais medidas com termografia em frangos de corte podem servir como base para inferir condições inadequadas de alojamento no ambiente de produção. O objetivo deste trabalho foi quantificar as temperaturas superficiais de frangos de corte em diferentes condições de alojamento, em ambiente controlado e no campo, e associar com condições do ambiente térmico. O experimento foi dividido em três etapas, na primeira foi analisada a variação da temperatura superficial média das aves em diferentes temperaturas do ar em câmara climática para diferentes idades. A segunda etapa foi realizada a campo em dois aviários, os quais foram registrados semanalmente os parâmetros ambientais internos e externos dos aviários e imagens termográficas da cama de frango, do forro e das membranas laterais (cortinas) associando com a temperatura superficial das aves. A eficiência térmica do alojamento foi feita comparando a perda de calor das aves nos dois aviários. Na terceira etapa foi proposto um índice Fuzzy de conforto térmico de frangos de corte com base na sua temperatura superficial. Com o auxílio da termografia foi possível calcular a temperatura superficial média de frangos de corte através da análise das imagens termográficas. Na análise termográfica a campo, concluiu-se que a temperatura superficial média de frangos de corte está mais associada à temperatura superficial do entorno de produção (cortinas laterais, forro e a cama de frango). Com base na variação da temperatura superficial média das aves utilizadas na pesquisa foi gerado o índice Fuzzy de conforto térmico (IFCT) que permite estimar condições de conforto térmico em condições tropicais, especifico na estimativa da condição de perigo térmico. A utilização das câmeras termográficas para aferição da temperatura superficial de frangos de corte pode ser utilizada para estimar condições de conforto térmico de frangos de corte em diferentes condições de alojamento / Abstract: The production of broiler chickens is of great importance in the Brazilian economy and the country is the third largest world producer and leading exporter of broiler meat. One problem in the activity is the environmental heat stress, which impacts negatively on production. This research suggests that the surface temperatures measured with thermography in broiler chickens may serve as a basis for inferring improper housing conditions in the production environment. The objective is to measure the surface temperatures of broilers in different housing conditions and associate with the weather. The experiment was divided into three stages: first, we analyzed the variation of mean surface temperature of the birds at different air temperatures and climate in the camera at different ages. The second stage was conducted in the field in two poultry houses in two different periods of accommodation, which were followed weekly by recording the climatic and environmental variables and the infrared thermographic images of poultry litter, and the membranes used in the sides, correlating it with the surface temperature of the birds, and the thermal efficiency of housing was done by comparing the heat loss of birds in two houses. In the third step it was proposed a fuzzy index of thermal comfort for broilers based on its surface temperature. With the aid of infrared thermal imaging it was possible to calculate the mean surface temperature of broilers by image analysis, without the need of using equations to estimate this. Using the infrared thermal image analysis conducted in the field, we conclude that the mean surface temperature of broiler chickens is more correlated to the surface temperature of the production environment (side curtains/ membranes, litter and chicken). Based on the variation of mean surface temperature of the birds used was generated Fuzzy index of thermal comfort (FITC) that allows estimating the thermal comfort in tropical conditions, to predict the specific condition of thermal hazard. The use of infrared technology to calculate the surface temperature of broilers, with the aid of thermographic cameras, gives out a basis for estimating the thermal comfort of broiler chickens in different housing conditions / Mestrado / Construções Rurais e Ambiencia / Mestre em Engenharia Agrícola
163

Conforto termico nos espaços de transição e sua influencia como elemento apaziguador do microclima local / The thermal comfort in transitional spaces and its influence as an appeaser of the local microclimate

Skubs, Danielle 14 August 2018 (has links)
Orientador: Lucila Chebel Labaki / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-14T03:21:16Z (GMT). No. of bitstreams: 1 Skubs_Danielle.pdf: 14200776 bytes, checksum: 3848b0e7f767b5ebf3f638f9c66c4f0b (MD5) Previous issue date: 2009 / Resumo: As áreas de transição têm especificidades por suas características construtivas e por serem espaços influenciados tanto pelo clima externo como pela edificação a que pertencem. Ainda são escassos os estudos sobre este tema no Brasil. Aceita-se que em regiões quentes estes ambientes podem minimizar o choque térmico dos usuários na passagem interior ao exterior, compor ambientes de microclima local agradável, tornando os espaços mais confortáveis e receptivos. O objetivo deste trabalho é avaliar a importância da área de transição como elemento apaziguador do microclima local e a percepção dos usuários para este fato, adotando como objeto de estudo duas instituições de ensino, de Piracicaba e Santa Bárbara D'Oeste, SP. A metodologia adotada baseou-se na aplicação de questionários, realização de medições dos parâmetros ambientais e registro, através de croquis e anotações, da implantação e características construtivas dos ambientes analisados. As medições forneceram dados para a análise do comportamento térmico das áreas de transição e salas de aula e os questionários foram utilizados para avaliar as sensações, preferências térmicas e impressões dos usuários em relação a estas, através do cálculo do Voto Médio Estimado (VME). Os resultados da pesquisa mostraram que a escolha dos materiais e a configuração do espaço de transição são fundamentais para o conforto térmico e indicaram que os usuários percebem a importância da área de transição como elemento apaziguador do choque térmico causado pela diferença de temperaturas entre área interna e externa. A relevância deste trabalho está em mostrar que estas áreas podem ser ambientes confortáveis e espaços agradáveis, que contribuem para o conforto térmico dos ambientes e proporcionam maior qualidade de vida aos usuários, mostrando ainda potencial auxílio de economia de energia. / Abstract: Transitional areas have specificities due to their constructive characteristics and to the way in which these spaces are influenced by the outdoor climate and the building which they belong to. There are few studies on this issue in Brazil. It's accepted that in hot environments regions, these areas can minimize the users' thermal impact in the transition indoor - outdoor and can provide pleasant local microclimate environments, creating more comfortable and receptive spaces. The goal of this study is to evaluate the importance of the transitional areas as an appeaser of local microclimate as well as the users' perception to this fact, adopting by study object two educational institutions of Piracicaba and Santa Bárbara D'Oeste, SP - Brazil. The methodology is based in the use of questionnaires, measurements of environmental parameters and the record of implantation and constructive characteristics of the analyzed environments, through sketches and notes. The measurements provided data for analysis of the transitional areas and classrooms' thermal behavior and the questionnaires were used to evaluate the users' thermal sensations, preferences and perceptions, through the Predicted Mean Vote (PMV) calculation. The results of this research have shown that the choice of materials and the configuration of the transition area are fundamental to thermal comfort and also indicated that users understand the importance of this space as an appeaser of thermal impact caused by the temperatures difference between indoor and outdoor environments. The relevance of this research consists in showing that these areas may be comfortable spaces and nice environments, also contributing to environment's thermal comfort and providing better quality of life to their users, showing also potential support for energy saving. / Universidade Estadual de Campi / Arquitetura e Construção / Mestre em Engenharia Civil
164

Desempenho termico da espuma poliuretana a base de oleo de mamona utilizada em componentes da edificação (subcoberturas) : estudo em Ilha Solteira, SP / Thermal performance of a castor oil foam as insulating material inside the roof : study case in the city of Ilha Solteira, Brazil

Lopes, Edmar Maria Lima 05 April 2009 (has links)
Orientador: Lucila Chebel Labaki / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-14T03:28:06Z (GMT). No. of bitstreams: 1 Lopes_EdmarMariaLima.pdf: 8612445 bytes, checksum: 69659b28ac6e14c5f71ca12f206444ac (MD5) Previous issue date: 2009 / Resumo: O óleo de mamona após seu processamento e síntese, dá origem a uma poliuretana, termicamente compatível com as poliuretanas de origem petroquímica, mas com toxidade quase nula e baixa flamabilidade. A utilização da espuma de mamona é ecologicamente correta por tratar-se de uma fonte vegetal renovável, não tóxica durante o seu manuseio Através da experimentação de 4 (quatro) células-teste em escala 1: 1 foram utilizadas placas de espuma poliuretana de mamona, como isolante térmico em coberturas. A diferença entre as células-teste apresenta-se na localização das placas de resina poliuretana. Na quarta célula-teste (casa 4), está localizada a central de tomada dos dados. Na primeira (casa 1), a espuma poliuretana encontra-se em forma "sandwich", localizada entre as telhas de fibrocimento. A segunda (casa 2), não possui nenhum tipo de isolamento térmico - é a célula-teste utilizada como referência para este estudo e na terceira (casa 3), a espuma poliuretana é colocada diretamente sobre a laje. O trabalho teve como objetivo verificar comparativamente, a resposta térmica das coberturas utilizando a espuma poliuretana de mamona como isolante térmico na cobertura, englobando duas estações climáticas, final do verão e o inverno. Em diferentes períodos da pesquisa utilizou-se as telhas de fibrocimento em sua cor natural e com a telha pintada na cor branca. Foram registradas as temperaturas de bulbo seco, bulbo úmido e de globo internas e externas do ar e as temperaturas superficiais dos elementos construtivos componentes da cobertura. A análise dos dados foi feita comparando-se as temperaturas de cada uma das células - teste, com as temperaturas externas, tomadas por uma pequena estação meteorológica. O experimento foi desenvolvido na cidade de Ilha Solteira/SP, região noroeste do estado A célula-teste 1 (casa 1), que possui o isolante térmico em forma "sandwich " entre as telhas e com as telhas pintadas na cor branca, apresentou melhor desempenho térmico, para utilização no inverno-seco e, a célula-teste 3 (casa 3), com o isolante diretamente sobre a laje e com as telhas pintadas de branco, demonstrou melhor comportamento térmico no verão quente-úmido. / Abstract: The aim of this work is to describe an experimental study using castor oil foam as an insulating material inside the roof. The castor oil foam inside the roof is an appropriate natural recycled material as a passive cooling strategy as opposite to the burning of fossil fuels for air conditioning (AC) and mechanical ventilation. The expected result of this research is the possibility of contributing to improve thermal comfort and quality of life in the built environment. This experimental study is based on collecting data under real climate conditions of temperature and humidity to investigated the thermal performance in four test-cells with castor oil foam inside their roofs, in the city of Ilha Solteira located at northwest region of São Paulo State, in Brazil. In this research four test-cells constructions were used for data collection of ambient and surfaces temperatures with dimensions 3,00 x 2,00 x 2,50 m in real scale. The first test-cell was composed with insulating material like a sandwich. The second one with no insulating material was taken by reference. The third one was had insulating material on the flag and on the fourth was found the central of data collection. This work compared about the behavior in the test-cells applying castor oil foam on four different periods of the year: two on the summer and two in the winter. Results showed up the best thermal performance on the summer period was demonstrated on the test-cell no 3, presenting white roofing. Otherwise in the winter, the best thermal behavior was presented on the test cell no 1, with white roofing, too. / Universidade Estadual de Campi / Arquitetura e Construção / Doutor em Engenharia Civil
165

Desempenho termico e consumo energetico de edificios de escritorios em São Carlos, SP / Thermal performance and energy consumption of buildings of offices in São Carlos, SP

Carrieres, Kellen Regina Monte 31 August 2007 (has links)
Orientador: Mauricio Roriz / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-10T23:32:10Z (GMT). No. of bitstreams: 1 Carrieres_KellenReginaMonte_M.pdf: 2055164 bytes, checksum: cdcb2f87b28224c87a8002fe4b58dab8 (MD5) Previous issue date: 2007 / Resumo: Com a crise energética e o alto consumo de eletricidade, é crescente a preocupação com a economia de energia, principalmente em edifícios dos setores públicos e comerciais, pois são os grandes consumidores. Com isso, muitos pesquisadores da área estão direcionando suas pesquisas científicas para o estudo do conforto térmico do homem, em busca de edifícios mais eficientes energeticamente. Baseado nesses fatos, esse trabalho avalia a influência de parâmetros construtivos com relação ao consumo de energia e ao conforto térmico de edifícios de escritórios da cidade de São Carlos, de forma a adequar os edifícios ao clima da cidade. Para tal análise, foram estudados seis edifícios com relação à caracterização construtiva, dos quais três foram escolhidos para o levantamento do padrão de uso e ocupação desse tipo de edificação, e para monitoramento de temperatura e umidade relativa do ar. Foram realizadas para o clima da cidade, simulações de um edifício de referência que apresenta alguns parâmetros fixos, que foram adotados por representarem os sistemas construtivos mais utilizados no Brasil, e outros variáveis como a orientação, sistema construtivo, porcentagem de vidro na fachada, absortância da fachada e da cobertura e renovações de ar. Cada parâmetro variável foi simulado com todos os outros fixos, obtendo-se assim resultados reais da influência de cada um. Os resultados dessas simulações foram analisados estatisticamente por regressão linear múltipla. Com essa análise pôde-se determinar a influência de cada parâmetro no consumo de energia. A absortância da cobertura foi o parâmetro que mais influenciou no consumo, chegando a 160% a mais no mês de junho e 238% a mais no mês de dezembro, isso em relação a absortância da fachada, parâmetro de menor influência nesses modelos. Além disso, foram calculadas as diferenças de consumo entre os maiores e menores valores para todas as combinações adotadas nesse trabalho, chegando as situações ideais para o consumo de aquecimento e resfriamento. Em todos os casos, com exceção da capacidade térmica do sistema construtivo, os menores valores de cada parâmetro foram os que obtiveram um menor consumo total em todas as situações / Abstract: Due to the energetic crisis and the high demand for electricity, the concern about power saving is growing, mainly at public and commercial buildings, as they are the greatest consumers. Therefore, many researchers of the area are directing their scientific researches towards the study of mankind thermal comfort, aiming more energetically efficient buildings. Based upon these facts, this work evaluates the influence of construction parameters in relation to energy consumption and thermal comfort of office buildings located in the city of Sao Carlos, in order to adequate the buildings to the city climate. For such analysis, six buildings were studied regarding constructive characterization and three of them were chosen to be assessed by the use and occupancy patterns of this type of building and for temperature and air relative humidity monitoring. According to the city climate, simulations were performed for a reference building with some fixed parameters, which were adopted as representing the most used building systems in Brazil and other variables such as orientation, building system, the percentage of glass in the façade, façade and roof absortance and air renovation. Each variable parameter was simulated having all others fixed, obtaining real results of their individual influences. The results of these simulations were statistically analyzed by multiple linear regression. Through this analysis it was possible to determine the influence of each parameter in the energy consumption. The roof absortance was the parameter that most influenced the consumption, reaching a 160% increase in the month of June and 238% in December, regarding the façade absortance, the less influential parameter in these models. Besides that, the differences of consumption between bigger and smaller values for all the combinations adopted in this work were calculated, reaching ideal situations for the warming and cooling consumptions. In all cases, except for the thermal capacity of the building system, the smaller values of each parameter were the ones that obtained the minor total consumption in all situations / Mestrado / Edificações / Mestre em Engenharia Civil
166

Absortancia solar de superficies opacas : metodos de determminação e base de dados para tintas latex acrilica e PVA / Solar absorptance of opaque surfaces : a determination methods and data base for latex acrylic and PVA coatings

Dornelles, Kelen Almeida 16 April 2008 (has links)
Orientador: Mauricio Roriz / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-11T13:02:36Z (GMT). No. of bitstreams: 1 Dornelles_KelenAlmeida_D.pdf: 6559934 bytes, checksum: 3966f1604b84180c07c07723d60bf746 (MD5) Previous issue date: 2008 / Resumo: A radiação solar é responsável por importante parcela da carga térmica dos edifícios e seu impacto sobre esta carga depende, principalmente, da absortância solar do envelope construtivo. A falta de dados precisos e atualizados de absortância solar para superfícies opacas faz com que pesquisadores e especialistas utilizem a percepção visual ou adotem tabelas baseadas em cores, consagrando-se o conceito de que a absortância seria crescente na medida em que as cores fossem mais escuras. Para comprovar que a visão humana não é instrumento adequado para indicar o quanto uma superfície absorve de energia solar, este trabalho apresenta dados de absortância solar para diferentes cores e tipos de tintas utilizadas em superfícies opacas de edificações no Brasil, a partir de medições de refletância em espectrofotômetro. Com base nesses dados, são propostos métodos de determinação da absortância solar de superfícies opacas, que podem ser utilizados por projetistas, pesquisadores e especialistas. Além do espectrofotômetro, apresenta-se um método que se baseia na digitalização de amostras em scanner comum e posterior classificação de suas cores a partir dos sistemas cromáticos digitais RGB e HSL. O segundo método utiliza dados de refletância obtidos através do espectrômetro ALTA II e o terceiro método baseia-se em medidas de temperaturas superficiais das amostras, a partir de absortâncias medidas para amostras de cores branca e preta, adotadas como referência. Os dados de absortância solar obtidos com o espectrofotômetro foram ajustados ao espectro solar padrão, considerando-se que a energia solar não é constante ao longo do espectro. Este ajuste indicou que a absortância diminui quando submetida às diferentes intensidades da radiação solar. Finalmente, analisou-se o efeito da rugosidade superficial sobre a absortância solar de amostras pintadas com diferentes cores de tintas, cujos resultados indicaram que a rugosidade aumenta linearmente a absortância das superfícies. As diversas análises e discussões apresentadas neste trabalho comprovam que apenas a cor não é fator determinante da absortância de uma superfície opaca. Além disso, os métodos propostos para sua quantificação são bastante precisos e confiáveis, cujos valores estimados através dos métodos do scanner, ALTA II e medida de temperaturas superficiais apresentaram diferenças inferiores a 10%, 6,8% e 3,7%, respectivamente, quando comparados com as absortâncias medidas em espectrofotômetro / Abstract: Solar radiation is the main responsible factor for the thermal load of buildings, and its impact over this load depends, mainly, on the solar absorptance of the building envelope. The lack of reliable and current data implies that researchers and specialists use visual perception or adopt tables based on surface colors to quantify the solar absorptance, which enhances the concept that absorptance increases as much as colors are darker. In order to show that the human eye is not reliable indicator of how much solar energy a surface absorbs, this work presents solar absorptance data for different paint colors, which are commonly used in Brazilian façades, measured with a spectrophotometer. Based on these data, determination methods of solar absorptance are proposed and can be used by designers, researchers, and specialists. Besides the spectrophotometer, it is presented a method based on samples digital images through a scanner, in which samples were classified according to the RGB and HSL digital chromatic systems. The second method uses the reflectances of samples measured with the ALTA II spectrometer, and the third method is based on the samples surface temperatures and the absorptances of black and white reference samples. Solar absorptance data measured with the spectrophotometer were adjusted to the standard solar spectrum, because the solar energy is not constant along the solar spectrum. This correction indicated solar absorptance diminishes when submitted to different solar radiation intensities. Finally, the influence of roughness on the solar absorptance was analyzed, whose results indicated roughness linearly increases surfaces solar absorptance. The several analysis and discussions presented in this work prove that only color is not a determinant factor of the solar absorptance. Furthermore, proposed methods are very reliable to identify the solar absorptance of opaque surfaces, whose estimated values with scanner, ALTA II, and surface temperature methods presented differences under 10%, 6,8%, and 3,7%, respectively, when compared to the absorptances measured with the spectrophotometer / Doutorado / Arquitetura e Construção / Doutor em Engenharia Civil
167

Avaliação da escala de influencia da vegetação no microclima por diferentes especies arboreas / Evaluation of the radius of influence of different arboreal species on microclimate provided by vegetation

Abreu, Loyde Vieira de 08 August 2008 (has links)
Orientador: Lucila Chebel Labaki / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-11T18:01:44Z (GMT). No. of bitstreams: 1 Abreu_LoydeVieirade_M.pdf: 20856147 bytes, checksum: 34f178529845a3a7df704cf070c1457b (MD5) Previous issue date: 2008 / Resumo: É conhecido o papel da vegetação na mitigação do calor gerado no ambiente urbano e na redução do consumo energético para refrigeração dos edifícios. A vegetação tem uma influência significativa no conforto térmico em ambientes externos. Existem, porém, poucos dados conhecidos sobre a quantificação dos benefícios trazidos pelos indivíduos e agrupamentos arbóreos, como a atenuação da radiação solar incidente e a umidificação dos ambientes devido à evapotranspiração das plantas. Este trabalho tem como premissa que as diferentes espécies arbóreas se comportam de maneiras distintas no microclima urbano, em função de suas características morfológicas. O objetivo dessa pesquisa é identificar o raio de influência no conforto térmico alcançado por espécies arbóreas encontradas na região da cidade de Campinas, SP. A metodologia consistiu na identificação das espécies a serem analisadas e em medições dos parâmetros ambientais - temperatura do ar, umidade relativa, velocidade do vento, em pontos situados à sombra da copa e ao sol, em diferentes distâncias do tronco. A radiação solar incidente foi medida com solarímetros de tubo, em dois pontos, à sombra e ao sol. As medições foram realizadas no período diurno, do amanhecer ao anoitecer, durante três dias, espaçados ao longo do ano, em diferentes estações. Foram analisadas cinco espécies arbóreas: Ipê-Amarelo (Tabebuia chrysotricha (Mart. ex DC.) Stand.), Jacarandá (Jacaranda mimosaefolia D. Don.), Jambolão (Syzygium cumini L.), Mangueira (Mangifera indica L.), e Chuva de Ouro (Senna siamea L.). A análise dos dados compreendeu o cálculo da atenuação da radiação solar incidente, da evapotranspiração e avaliação de conforto térmico nas diferentes distâncias, de acordo com uma zona de conforto tridimensional para a região de Campinas. Os dados foram analisados estatisticamente pelo teste de Tukey. Os resultados mostraram que a maior contribuição para o conforto foi do agrupamento arbóreo. Para árvores isoladas, observa-se uma influência importante do Índice de Área Foliar (IAF) e da dimensão das folhas. Em relação ao conforto térmico, uma constatação de grande significado é que até uma distância em torno de 15m do tronco o conjunto de variáveis ambientais proporciona conforto térmico, mesmo ao sol. Um comportamento peculiar foi observado em relação à umidade relativa: a certa distância, em torno de 10m do tronco, esse parâmetro é mais elevado que à sombra, diminuindo com maiores distâncias. A pesquisa sugere importantes investigações futuras: a interpretação do comportamento da umidade relativa, a relação entre a evapotranspiração e a umidade ao longo do dia. Vislumbra-se a elaboração de um modelo que explique o comportamento das espécies analisadas em função de suas características morfológicas e permita simulações para as demais espécies. / Abstract: It is a well known fact the role of vegetation in mitigating the heat generated in the urban environment and in reducing the energy consumed for cooling of buildings. The vegetation has a significant influence on thermal comfort in outdoor spaces. However there are few data available that quantify the benefits that individuals and groupings of trees bring to the environment, such as the attenuation of incident solar radiation and air humidification due to the process of evapotranspiration. The premise of this work is that different tree species behave in different ways in urban microclimate, according to their morphological characteristics. The aim of the research is to identify the radius of influence on thermal comfort achieved by tree species and their arrangement. The species are those found in the region of Campinas city, Brazil. The adopted methodology consisted in identifying the species to be analyzed, measurements of environmental parameters - air temperature, relative humidity, wind speed, in points located in the shadow of the crown and at sunshine, at different distances from the trunk. The incident solar radiation was measured with tube solarimeters, in two points, in the shadow and at sun. The measurements were carried out during the day, from sunrise to sunset, in three days, spaced throughout the year, in periods of different seasons. Five tree species were analyzed: Tabebuia chrysotricha (Mart. ex DC.) Stand.), Jacarandá (Jacaranda mimosaefolia D. Don.), Jambolão (Syzygium cumini L.), Mangueira (Mangifera indica L.), and Chuva de Ouro (Senna siamea L.). Data analysis included calculating the attenuation of incident solar radiation, evapotranspiration, and evaluation of thermal comfort at different distances, according to the three-dimensional comfort zone for the region of Campinas. Tukey tests were used for statistical analyzes. Results show that the best contribution to comfort was from the tree grouping. For isolated trees, there is an important influence of the Leaf Area Index (IAF) and the size of the leaves. Regarding thermal comfort, a finding of great significance is that up to a distance of 15m from the trunk, the set of environmental variables provides thermal comfort, even in the sun. A peculiar behaviour was observed in relation to the relative humidity: at certain distance, around 10m from the trunk, this parameter is higher than in the shade, and decreases with greater distances. The research suggests important future investigations: the interpretation of the behaviour of relative humidity, the relationship between evapotranspiration and humidity throughout the day. The development of a model to explain the observed behaviour of the species as a function of their morphological characteristics can also be proposed allowing simulations for the other species. / Mestrado / Arquitetura e Construção / Mestre em Engenharia Civil
168

Conforto térmico e a prática do projeto de edificações: recomendações para Ribeirão Preto / Thermal comfort and the practice of building design: recommendations for Ribeirão Preto

Luciana Pagnano Ribeiro 13 November 2008 (has links)
Em virtude do rigoroso clima quente da cidade de Ribeirão Preto, a questão do conforto térmico assume destacada relevância no projeto de edificações. Porém, como em outros locais, os significativos avanços nas pesquisas em conforto térmico no ambiente construído não têm se refletido na prática do projeto de edificações na cidade. Assim, o objetivo deste trabalho é gerar um conjunto de recomendações de projeto para edificações em Ribeirão Preto, sob a ótica do conforto térmico. São recomendações gerais e de fácil aplicação, voltadas às primeiras fases do processo de projeto, e que buscam uma maior aproximação dos profissionais projetistas com os conceitos de conforto térmico no ambiente construído. Para a elaboração deste conjunto de recomendações, utilizou-se como parâmetro um método e uma norma existentes, além de uma detalhada análise dos componentes e particularidades climáticas locais. / Towards the high temperatures the city of Ribeirão Preto presents, the thermal comfort became a very important issue in the building design. However, as at other locations, the significant progress of research in thermal comfort in the internal environment does not have been reflected in the practicing professional in the city. The objective of this work is to deliver some recommendations for design building in Ribeirão Preto, under the thermal comfort concept. These are general recommendations and easy to be used, focused at the first project phases, reaching the professionals with the concepts of thermal comfort in the internal environment. For these recommendations, were used as a method a parameter and a standard and a detailed analysis of existing components and features local climate.
169

Avaliação do desempenho térmico de vidros refletivos: estudo de caso em células - teste / Evaluation of the thermal performance of reflective glasses: study of case in test-cells

Rubia Michelato 04 June 2007 (has links)
As superfícies transparentes são bastante frágeis no que se refere ao ganho de calor, permitindo facilmente a entrada da radiação solar no interior das edificações. A proporção entre as superfícies transparentes e as opacas de uma edificação constitui um fator decisivo no conforto ambiental, já que grandes áreas envidraçadas usadas sem nenhum critério são as principais responsáveis pelo ganho de calor no interior dos edifícios. O objetivo do trabalho é estudar o comportamento dos vidros refletivos pirolíticos e metalizados a vácuo em fachadas com relação ao ganho de calor solar. Para tanto, foram realizadas medições em células-teste construídas na UNICAMP com janelas providas desses vidros. Foram analisados nove tipos de vidros, sendo dois planos, quatro refletivos pirolíticos e três refletivos metalizados a vácuo, cuja caracterização através do espectrofotômetro já havia sido feita anteriormente. Analisou-se o desempenho térmico de cada vidro, tendo como referência o vidro plano incolor. A pesquisa consistiu na obtenção de dados através de ensaios de campo e no cálculo do ganho de calor. Dessa forma foi possível fazer uma análise das condições térmicas proporcionadas por esses vidros, verificando se eles constituem uma boa opção para a arquitetura contemporânea e se eles resultam em uma melhor eficiência energética. Dentre os vidros analisados, os vidros refletivos metalizados a vácuo apresentaram o melhor desempenho térmico no que se refere ao menor ganho de calor solar. / The glassed surfaces are so fragile concerning gain of heat, allowing the easy entrance of solar radiation in the interior of buildings. The proportion between glassed surfaces and opaque ones of a building is a decisive factor in the environment comfort, as the big glassed areas used without criterion are the principal responsible for the gain of heat in the interior of buildings. The objective of the work is to study the performance of the reflective glasses produced by pyrolitic process and the reflective glasses obtained by vacuum metal deposition in façades with reference to the gain of solar heat. For this, measurements were made in test-cells constructed at UNICAMP with windows with these glasses. Nine types of glasses were analyzed, two float glasses, four reflective glasses produced by pyrolitic process and three reflective glasses obtained by vacuum metal deposition, whose spectrophotometrical characterization was made before. It was analyzed the thermal performance of each glass, having as reference the colorless float glass. The search consisted of the acquisition of results through measurements in field and through the calculation of heat gain. This way, it was possible to make an analysis of the thermal conditions provided by these glasses, checking if they are a good option for the contemporary architecture and if they result in better energy efficiency. Among the analyzed glasses, the reflective glasses obtained by vacuum metal deposition presented the best thermal performance with reference to solar heat gain.
170

Desempenho térmico de diferentes tipos de telhado em bezerreiros individuais. / Thermal performance from different types of roof in individual calf housing.

Celso Yoji Kawabata 08 July 2003 (has links)
Neste trabalho, foi pesquisada a eficiência de abrigos individuais para bezerros, a partir de índices de conforto térmico (carga térmica radiante, índice de temperatura de globo e umidade e índice de globo negro) calculados com base na temperatura ambiente, temperatura de globo negro e umidade relativa do ar, comparando-se abrigos cobertos por telha de cimento celulose ou telha de cimento amianto comercial. O experimento foi implantado num sistema de abrigos convencionais, tipo boxe, com cinco tratamentos diferentes e cinco repetições por tratamento (um bezerro por repetição), durante os meses de setembro a novembro de 2002. Foram registradas variáveis fisiológicas de termorregulação (freqüência respiratória e temperatura retal). As telhas de cimento celulose foram caracterizadas por meio de testes físicos e mecânicos com resultados aceitáveis. Estimou-se o custo final da produção da telha de cimento celulose, que se mostrou vantajoso em relação a outras opções de cobertura com telha cerâmica. Os abrigos expostos ao sol e cobertos com telha de cimento amianto apresentaram os índices menos satisfatórios quanto ao conforto térmico animal, em relação aos demais abrigos também expostos ao sol. Já os abrigos cobertos com telhas de cimento celulose apresentaram os melhores índices de conforto térmico animal, quando estes estavam dispostos em área sombreada. Os resultados das variáveis fisiológicas também foram significativamente melhores para os tratamentos posicionado à sombra. Encontrou-se uma relação satisfatória entre os resultados de conforto térmico e os resultados fisiológicos. / This work focused the efficiency of individual housing for calves, based on thermal comfort indexes (radiant thermic load, black globe humidity index and black globe index) that were calculated with ambient temperature, black globe temperature and relative humidity of the air. Animal housing covered with cellulose cement tiles were compared with commercial asbestos cement tiles. The experiment was installed in a system of conventional housing, box type, with five different treatments (one calf per repetition), during the period from September to December 2002. Physiological variables of thermoregulation (respiration rate and rectal temperature) were also registered during the experiment. The roofing tiles of cellulose cement were characterized by physical and mechanical tests with acceptable results. The final cost of the production of the cellulose cement tiled showed to be advantageous in relation to other options of roofing with ceramic tiles. The housing exposed to the sunlight and covered with asbestos cement tiles presented the less satisfactory results for the animal thermal comfort in comparison with the others treatments exposed to the sun. The housing covered with cellulose cement tiles under shade showed the best results of thermal comfort. The results of the physiological variables were significantly better for the treatment positioned under the shade. A satisfactory relation between the thermal comfort indexes and the physiological results were found in the conditions of the present work.

Page generated in 0.3187 seconds