• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 306
  • 96
  • 34
  • 21
  • 15
  • 9
  • 8
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 561
  • 561
  • 314
  • 292
  • 117
  • 83
  • 76
  • 74
  • 67
  • 66
  • 60
  • 59
  • 58
  • 58
  • 51
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
181

Cenários de impacto das propriedades da superfície sobre o conforto térmico humano na cidade de São Paulo / Scenarios of surface properties impacts over the human thermal comfort in the city of São Paulo.

Mariana Lino Gouvêa 17 December 2007 (has links)
Este projeto de pesquisa de mestrado buscou identificar os impactos das propriedades da superfície urbana sobre as condições meteorológicas da Região Metropolitana de São Paulo (RMSP), buscando um melhor entendimento dos mesmos para que atividades de planejamento urbano possam ser melhor organizadas. O trabalho utilizou como principais ferramentas produtos de sensoriamento remoto, para definir algumas propriedades da superfície urbana, medidas em superfície de variáveis meteorológicas, para determinação de índices de conforto humano, e a modelagem numérica da atmosfera, para identificação de condições atmosféricas e construção de cenários úteis ao planejamento urbano. Com o uso de imagens de satélite, foram criados arquivos de ocupação do solo e da fração vegetada na área urbana da RMSP em altíssima resolução (20 m). Após a definição das propriedades da superfície, valores medidos pela CETESB de temperatura e umidade relativa foram associados a padrões de ocupação urbana. Verificou-se que as regiões de São Caetano do Sul e do Parque D. Pedro II foram as que apresentaram o maior número de casos de desconforto por calor moderado. Regiões como São Miguel Paulista e Ibirapuera mostraram-se mais confortáveis. Na maior parte dos casos, as regiões apresentaram um nível agradável a levemente quente, seguidos pela condição agradável a levemente fresca. Após a análise diagnóstica, foram construídos cenários contemplando atividades de planejamento urbano em busca da melhoria das condições de conforto térmico humano. Os experimentos realizados indicam que os fluxos turbulentos em superfície são consideravelmente modificados e que a temperatura pode sofrer uma diminuição gradativa até cerca de 1,5 ºC com a substituição de 50% da superfície urbana por vegetação, chegando a mais de 2,2 ºC quando esta substituição é completa. O perfil de temperatura potencial na Camada Limite Planetária também foi consideravelmente modificado com o aumento da porção vegetada no domímio modelado. / This master\'s research project has the goal of indentifying the impacts of urban surface properties over the meteorological conditions of the Metropolitan Area of São Paulo (MASP), in order to obtain a better understanding of them and to provide means of better organized urban planning activities. The work was made by using as principal tools, remote sensing derived products, in order to define some surface properties, surface measurements of atmospheric variables, in order to obtain human thermal comfort indexes, and numerical modeling of the atmosphere, in order to identify atmospheric conditions and simulate useful scenaries for urban planning. By using sattelite images, land use and vegetated fraction files were created over the MASP with very high resolution (20 m). Afterwards, temperature and relative humidity measured by CETESB were associated to urban land use patterns. It was verified that regions like São Caetano do Sul and Parque D. Pedro II are more likely to have greater discomfort sensation by moderate heat. Regions like São Miguel Paulista and Ibirapuera were identified to be more confortable. In the majority of cases, the regions presented a pleasant to lightly warm, followed by pleasant to lightly fresh conditions. After the definition of the surface properties, scenarios were built comprehending urban planning activities, looking for the improvement of human thermal comfort conditions. The experiments showed that the surface turbulent fluxes are considerably changed and that temperature was gradualy reduced in up to 1,5 ºC with the replacement of 50% of the urban surface by vegetation, reaching more than 2,2 ºC when this replacement was complete. The potential temperature profile inside the Planetary Boundary Layer was also considerably modified following the increase of vegetated area in the modeled domain.
182

Desempenho térmico e visual de elementos transparentes frente à radiação solar / Thermal and visual performance of transparent elements related to the solar radiation

Joaquim Cesar Pizzutti dos Santos 23 August 2002 (has links)
A especificação das vedações transparentes é uma das decisões mais complexas no âmbito do projeto arquitetônico. Envolve diversos fatores construtivos e de necessidades humanas relacionadas ao conforto ambiental, associadas a uma grande variedade de produtos disponíveis no mercado. Este trabalho busca facilitar aos projetistas esse processo de especificação, fornecendo valores dos parâmetros de desempenho dos elementos transparentes em relação à análise do conforto térmico e visual, coerentes com a realidade climática brasileira e com a real incidência da radiação solar ao longo do dia. Foram estudados os vidros comuns, laminados e refletivos, e as películas de controle solar, policarbonatos e acrílicos usados em edificações no Brasil. Foi utilizada a análise por espectrofotometria para a obtenção dos valores de refletância, transmitância a absortância para as diferentes regiões do espectro solar, com ângulos de incidência variados. A partir do relacionamento desses resultados, considerando o comportamento similar de variação do Fator do Calor Solar (FCS) e da Transmitância da Luz Visível (Tv) com o ângulo de incidência, foi desenvolvida uma metodologia que possibilita o cálculo simplificado de ganhos de calor e luz natural. / The specification of the transparent elements is one of the most complex decisions in the ambit of the architectural project. It involves several constructive factors and human necessities related to the environmental comfort, associated to a great variety of available products in the market. The aim of this work is to facilitate the specification process to the planners, supplying values of the performance parameters of the transparent elements in relation to the analysis of thermal and visual comfort, coherent with the Brazilian climatic reality and with real incidence of the solar radiation along of the day. It were studied the ordinary, laminate and reflective glasses, the solar control films, policarbonates and acrylic used in Brazilian constructions. The spectrophotometry analysis was used to obtain the reflectance, the transmittance and the absortance values for the different regions of the solar spectrum, with varied incidence angles. Starting from the relationship of those results, considering the similar behavior of variation of the Solar Heat Factor (FCS) and of Transmittance of the Visible Light (Tv) with the incidence angle, it was developed a methodology that facilitates the simplified calculation of heat and natural light gains.
183

Avaliação da qualidade ambiental de estabelecimentos comerciais da região central de São Carlos, SP / Environmental quality assessment of commercial establishments in the central region of São Carlos, SP

Leandro Augusto Bassi Alves 21 June 2013 (has links)
Este estudo apresenta o diagnóstico da qualidade do ambiente interno de estabelecimentos comerciais da região central da cidade de São Carlos, localizada no interior do estado de São Paulo. Foram determinados os seguintes parâmetros: concentração mássica do material particulado em suspensão, em suas frações MP10 e MP2,5, níveis de ruído, temperatura e umidade relativa. A coleta de dados foi realizada em três locais por um período de sete horas diárias, das 10 h às 17 h. Os estabelecimentos comerciais da região central da cidade de São Carlos possuíram, em média, valores de temperatura 5,1°C maiores e de umidade relativa 35,5% menores que aqueles encontrados na estação meteorológica localizada na área rural da cidade. Foi encontrado alto coeficiente de correlação entre os dados climáticos das lojas e da estação meteorológica, indicando que o ambiente externo possui grande influência nos ambientes internos estudados. Do total dos dias amostrados, 54% foram indicados como desconfortáveis termicamente. As concentrações de MP2,5 variaram de 11,4 a 40,6 &#956g.m-3, estando acima do padrão de referência de 24 h da OMS (25 &#956g.m-3) em 35% dos dias amostrados. As concentrações de MP10 variaram de 18,4 a 85,7 &#956g.m-3, estando acima do padrão de referência de 24 h da OMS (50 &#956g.m-3) em 33% dos dias amostrados. A razão interno/externo (I/E) do material particulado foi em média de 0,82 para o MP2,5 e de 0,86 para o MP10. A concentração média das amostras de material particulado realizadas na estação seca foi 1,8 vezes maior do que das amostras realizadas na estação chuvosa para o MP10 e 1,2 vezes maior para o MP2,5. A razão MP2,5/MP10 média das amostras foi de 56%. O coeficiente de correlação entre os equipamentos utilizados para medida do material particulado foi de 0,40 para o MP2,5 e 0,53 para o MP10, sendo que as concentrações obtidas pelo equipamento contador de partículas foram em média 4,2 e 2,0 menores que as concentrações obtidas pelo equipamento gravimétrico para o MP2,5 e MP10, respectivamente. Os dados de ruído variaram de 50,6 a 67,2 dBA no ambiente interno e de 56,6 a 72,8 dBA no ambiente externo, com uma razão I/E média de 0,91. Com relação ao limite de 70 dBA estipulado pela OMS, 9% dos dias amostrados no ambiente externo ultrapassaram este valor. O ponto amostral mais ruidoso foi aquele localizado em frente à via com maior tráfego de veículos, e o menos ruidoso era localizado em frente a uma via com tráfego frequentemente congestionado. / This study presents the indoor environmental quality of stores in central São Carlos, an inner city of the state of São Paulo, in Brazil. The following parameters were monitored: mass concentration of particulate matter, in its fractions PM10 and PM2.5, noise levels, temperature and relative humidity. Data was collected in three stores in the center of town during seven hours daily, from 10 a.m. to 5 p.m. The stores had, in average, temperature values 5.1 °C higherand relative umidity 35.5% lower than those observed in a weather station located in the countryside. High correlation coefficient between the climate data in the stores and in the weather station was found, indicating that the external environment has great influence in the internal environments studied. Of all samples, 54% indicated thermal discomfort. PM2.5, mass concentrations ranged from 11.4 to 40.6 &#956g.m-3, exceeding the 24 h WHO guideline (25 &#956g.m-3) in 35% of the samples. PM10 mass concentrations ranged from 18.4 to 85.7 &#956g.m-3, exceeding the 24 h WHO guideline (50 &#956g.m-3) in 33% of the samples. The average inside/outside (I/O) ratio of the particulate matter was of 0.84 for the PM2.5 and 0.88 for the PM10. Mass concentration was 1.8 times greater in the dry season than in rainy season for the PM10, and 1.2 times greater for the PM2.5. Average PM2.5/PM10 ratio was 56%. Correlation coefficient between the gravimetric and particle counter equipments used to determine PM mass concentration was of 0.40 for the PM2.5 and 0.53 for the PM10, and latter had average means 4.2 and 2.0 times smaller, for PM2.5 and PM10, respectively. Noise levels ranged from 50.6 to 67.2 dBA in the internal environment and 56.6 to 72.8 dBA in the external environment, with an average I/O ratio of 0.91. Concerning the 70 dBA daily exposure limit estipulated by WHO, 9% of the sampled days exceeded that value. The location with higher noise pollution was located in front of the street with higher vehicle traffic, and the one with lower noise pollution was located in a street with often congested traffic.
184

Conforto térmico e consumo de energia em ambientes de um supermercado de médio porte / Thermal comfort and energy consumption environments in a midsize supermarket

Barbosa, Elisabeti de Fátima Teixeira, 1967- 24 August 2018 (has links)
Orientador: Lucila Chebel Labaki / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-24T00:03:28Z (GMT). No. of bitstreams: 1 Barbosa_ElisabetideFatimaTeixeira_M.pdf: 7798250 bytes, checksum: 9170364aaa7d255d00d409c30bdcd8b5 (MD5) Previous issue date: 2013 / Resumo: O conforto térmico tem sido amplamente pesquisado nos últimos anos, visando melhorar o bem estar das pessoas nos ambientes edificados, e minimizar o uso de energia elétrica para condicionamento artificial. Há algum tempo os estudos se direcionaram ao desempenho do ambiente construído de modo a obter uma boa relação entre pessoa-ambiente, principalmente quando se trata de ambientes de trabalho. No entanto, ainda é desconhecido o nível de conforto térmico proporcionado aos usuários de algumas edificações, principalmente em se tratando de edifícios de supermercados. Nos últimos anos, além de os empresários se preocuparem em garantir condicionamentos apropriados aos alimentos, em assegurar certo padrão de conforto aos seus clientes e propiciar bom nível de produtividade de seus funcionários, eles ainda tem que se preocupar em minimizar custos de energia. Nesse sentido, o levantamento do índice de conforto térmico e do consumo de energia em ambientes de supermercados se mostra importante para o conhecimento da real situação ambiental desse tipo de edificação. Esta pesquisa visou levantar dados do índice de conforto térmico e do consumo de energia no ambiente construído comercial do ramo alimentício. A metodologia empregada envolveu a seleção do supermercado, sua caracterização, o monitoramento das variáveis ambientais: temperatura do ar, umidade relativa, velocidade do ar e temperatura de globo, que permitem, juntamente com os dados relativos às variáveis pessoais, calcular o Voto Médio Estimado e a Porcentagem Estimada de Insatisfeitos. Foram levantados também os dados de consumo de energia. A análise dos resultados permitiu identificar a percepção térmica e o nível de satisfação dos usuários tanto de funcionários quanto dos clientes do supermercado. Os resultados indicam que no mês de maio/2011, 86% dos entrevistados preferiam o ambiente sem alteração e se sentiam confortáveis, e enquanto na área dos refrigeradores 55% dos entrevistados preferiam o ambiente sem alteração, e nesta mesma região, 32% preferiam o ambiente um pouco mais quente, ou seja, não estavam satisfeitos com o local, portanto preferiam mudanças. Os resultados indicam também que a temperatura do ar externo tem mais influência no consumo de energia que o número de usuários no supermercado pesquisado / Abstract: Thermal comfort has been widely researched in recent years to improve the welfare of people in the built environment, and minimize the use of electricity for artificial conditioning. For some time the studies were directed to the performance of the built environment in order to get a good relationship between person-environment, especially when it comes to working environments. However, it is still unknown what level of thermal comfort provided to the users of some buildings, especially in the case of buildings supermarket. In recent years, entrepreneurs have to bothering to ensure appropriate conditions to food, and ensure a certain standard of comfort to its customers and provide good level of productivity of their employees, in addition they still have to worry about minimizing energy costs. In this sense, the survey index of thermal comfort and energy consumption in supermarket environments proves important for understanding the real environmental situation of this type of building. This research examines data index of thermal comfort and energy consumption in the built environment of the commercial food industry. The methodology included the selection of the supermarket, characterization, monitoring of environmental variables: air temperature, relative humidity, air velocity and globe temperature, allowing, together with data on personal variables, calculate the Predicted Mean Vote and estimated Percentage of Dissatisfied. Also, data were collected from energy consumption. The analysis identified the thermal perception and level of satisfaction of users of both employees and customers of the supermarket. The results indicate that in the month of May/2011, 86% of respondents preferred the environment without alteration and felt comfortable, and while in the area of refrigerators 55% of respondents preferred the environment unchanged, and in the same region, 32% preferred the environment a little warmer, or were not satisfied with the location, so preferred changes. The results also indicate that the air temperature has more influence on energy consumption than the number of users in the supermarket researched / Mestrado / Arquitetura, Tecnologia e Cidade / Mestra em Arquitetura, Tecnologia e Cidade
185

Conforto térmico em salas de aula no Brasil = análise experimental e numérica / Thermal comfort in the classroom in Brazil : Experimental analysis and numeric

Moraes, Clélia Mendonça de 18 August 2018 (has links)
Orientadores: kamal Abdel Radi Ismail, Bjarne Wilkens Olesen / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecânica / Made available in DSpace on 2018-08-18T21:57:56Z (GMT). No. of bitstreams: 1 Moraes_CleliaMendoncade_D.pdf: 11219740 bytes, checksum: 58fccb247696bc4b704b7456032700a6 (MD5) Previous issue date: 2009 / Resumo: A qualidade da sala de aula é determinada pelo projeto da edificação. Esse, por sua vez, exerce uma forte influência sobre as condições térmicas do aluno em aula. A relevância de formularem-se normas e padrões específicos para esse tipo de ambiente que considere as suas particularidades é discutida em países como Dinamarca, Finlândia, Holanda, Suíça, Estados Unidos entre outros. No Brasil, como avaliação pós-ocupação. Sendo assim, a presente pesquisa avalia o comportamento térmico real em sala de aula com o levantamento de variáveis climatológicas do ambiente externo e interno da edificação localizada em duas universidades brasileiras no estado de São Paulo a fim de contribuir para o bem estar e produtividade. Por meio dos métodos de conforto térmico (Givoni, 1969) de ambientes envoltórios e sua correlação com a sensação térmica humana (Fanger, 1970) com a participação do aluno. Para estabelecer condições limite de conforto térmico em sala de aula, verificando as mudanças abruptas de temperatura em clima tropical de altitude. Adotou-se medida física objetiva e subjetiva. Monitoraram-se T(ºC), UR(%), Var(m/s) e P(atm); com o registro de dado interno por meio de "datalogger" e sensores; externo por Estação Meteorológica, e a percepção térmica do aluno foi avaliada com questionários. Aplicaram-se os dados obtidos no estudo do voto médio, ou seja, "CLO-FANGER-MET" interpolado com Givoni e nos softwares de simulação computacional de avaliação do desempenho ambiental de edificações. Os resultados finais obtidos com o cálculo numérico de sala de aula permitem obter uma avaliação de medidas padrões de uma temperatura ideal para salas de aula universitárias, estabelecendo o limite entre as zonas de conforto do metabolismo humano propondo um modelo adaptativo de conforto para um país com uma vasta variação latitudinal como o Brasil. Foi possível verificar através da análise da literatura que a qualidade do projeto da edificação determina a adaptação do homem ao clima / Abstract: The quality of the classroom is determined by edification Project. This exercise is a strong influence on the student's thermal conditions in classroom. The relevance of norms and specific patterns to the environmental that considers their particularities are discussed in countries such as Denmark, Finland, Holland, Switzerland, United States and among others. In Brazil, as post-occupation evaluation. In this manner, the research present evaluates the real thermal behavior in the classroom with the rising of climatology evaluation of external and internal environmental of the located edification in two Brazilian universities in the state of São Paulo in order to contribute to the comfort welfare and productive. Due to of thermal comfort methods (Givoni, 1969) of external environmental and his correlation with the human thermal sensation (Fanger, 1970) with the student's participation. Conditions establish limit of thermal comfort in classroom, verifying the abrupt changes of temperature in tropical climate of altitude. Physical measure was adopted aims at and subjective. Monitored T(ºC), UR (%), Var(m/s) and P(atm); with the registration of given internal through "datalogger" and sensor; external for Meteorological Station and the student's thermal perception was evaluated with questionnaires. The data were applied and obtained in the study of the medium vote, in other words, "CLO-FANGER-MET" interpolated with Givoni and in the softwares of computational simulation of evaluation of the environmental acting of constructions. The final results obtained with the numeric calculation of classroom allow to obtain an evaluation of measures patterns of an ideal temperature for university classrooms, establishing the limit between the areas of comfort of the human metabolism proposing a model comfort adaptation to a country with a vast latitudinal variation like Brazil. It was possible to verify through the analysis of the literature that the quality of the project of the construction determines the adaptation of the man to the climate / Doutorado / Termica e Fluidos / Doutor em Engenharia Mecânica
186

A influência do sombreamento do entorno na etiqueta de eficiência energética de edifício comercial / The influence of surrounding shading on the labelling of energy efficiency of a commercial building

Fernandes, Luciana Oliveira, 1984- 20 August 2018 (has links)
Orientador: Lucila Chebel Labaki / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-20T07:36:30Z (GMT). No. of bitstreams: 1 Fernandes_LucianaOliveira_M.pdf: 4185533 bytes, checksum: 77ac20bdb30c73e7e2c896ddaae5d13a (MD5) Previous issue date: 2012 / Resumo: O elevado consumo de energia elétrica pelas edificações brasileiras e o potencial de conservação de energia motivou a criação do "Programa Nacional de Eficiência Energética em Edificações" - PROCEL Edifica - a fim de avaliar e classificar o nível de eficiência energética desses edifícios. A consideração do entorno ao avaliar o nível de eficiência energética de um edifício pelo método da simulação, segundo os "Requisitos Técnicos da Qualidade para o Nível de Eficiência Energética de Edifícios Comerciais, de Serviços e Públicos" (RTQ-C), é opcional. Contudo, pesquisas destacam a influência da geometria urbana no desempenho energético das edificações. Nesta pesquisa foi analisada a influência do entorno sobre o uso da iluminação natural e sobre a etiqueta de eficiência energética de uma edificação comercial, através da simulação computacional. Para isso um modelo hipotético foi simulado nos softwares EnergyPlus e Daysim sob diferentes configurações de entorno e três sistemas de iluminação artificial. O primeiro permanece ligado durante o período de ocupação, o segundo é acionado pelo usuário quando necessário e o terceiro é utilizado por usuários passivos, mas controlado por dimmers. A metodologia utilizada para avaliação do nível de eficiência do edifício se baseia na recomendação do RTQ-C que consiste em comparar o consumo de energia do edifício proposto com edifícios similares cujas características correspondem aos níveis de eficiência. Tomando como referência os modelos cuja iluminação artificial permanece acesa durante todo o período de ocupação, os modelos com sistema controlado por interruptor apresentou uma economia média de 71% no consumo com iluminação e 35% no consumo total. O sistema com dimmers resultou em uma economia média de 50% e 23% respectivamente. No caso estudado, ambos os sistemas permitiram elevar o nível de eficiência energética do edifício proposto / Abstract: The high energy consumption of Brazilian buildings and the potential of energy savings have stimulated the establishments of the "National Program for Energy Efficiency of Buildings" - PROCEL Edifica - which evaluates and classifies the level of energy efficiency of these buildings. The "Quality Technical Requirements for the Energy Efficiency Level of Commercial, Services and Public Buildings" (RTQ-C) considers the modeling of the surroundings of the building optional to evaluate its energy efficiency by computational simulation. Nevertheless, researches indicate that urban geometry influences the energy performance of buildings. In this research it was analyzed the influence of the surroundings on the use of daylight in a non-residential building and thereafter on its energy efficiency label by means of computer simulation. For this purpose, a theoretical model of a non-residential building was simulated using the softwares Energy Plus and Daysim with different surroundings and three distinct electric lighting systems. The first one remains active during working hours. The second is activated by the user when needed, and the last one is triggered by passive users but controlled by dimmers. The methodology to evaluate the level of energy efficiency is based on the RTQ-C by which the energy consumption of the proposed building must be compared with similar buildings whose technical features match different levels of efficiency. With reference to the first system, the system controlled by the user resulted in an average economy of 71% on lighting annual consumption and 35% on total annual consumption. The dimmer system had an average economy of 50% and 23% respectively. In this case, both of the systems allowed raising the level of energy efficiency of the theoretical model / Mestrado / Arquitetura e Construção / Mestre em Engenharia Civil
187

Conforto térmico e iluminação natural no edifício administrativo da Escola de Engenharia de São Carlos: o bloco E1 / Architecture, thermal comfort and natural illumination in the administrative building of the School of Engineering of São Carlos / USP: the E1 block

Cíntia Cristina Vieira 06 August 2008 (has links)
A presente pesquisa consiste em uma análise do edifício administrativo da Escola de Engenharia de São Carlos pertencente à Universidade de São Paulo, do ponto de vista de conforto térmico e iluminação natural. O processo de investigação se dá em algumas etapas: análise projetual enfatizando os aspectos relativos ao conforto ambiental (microclima, partidos arquitetônicos, implantação, materiais, técnicas construtivas, aberturas, envidraçamentos, diagramas e esquemas de estudo); aplicação de questionários aos usuários; e medições in loco de níveis de iluminação e de variáveis ambientais de conforto térmico. Os resultados foram analisados e comparados, para que a partir destes seja possível obter uma avaliação das soluções e técnicas empregadas quanto às questões de térmica e iluminação, contribuindo assim no aperfeiçoamento de técnicas projetuais. Objetiva-se com estas técnicas a obtenção de conforto ambiental e redução no consumo de energia, para edifícios do padrão do estudado, o qual é visto repetir-se incalculavelmente em edifícios administrativos, de escritórios e escolares. / This research is an analysis of the administrative building of the Escola de Engenharia de São Carlos belonging to the Universidade de Sao Paulo, from the point of view of thermal comfort and natural illumination. The process of investigation takes place in some steps: architectural design analysis emphasizing aspects related to environmental comfort (microclimate, architectural parties, implantation, materials, constructive techniques, openings, glassing, diagrams, and study schemes); application of questionnaires to users, and on-site measurements of environmental variables of thermal comfort and levels of illumination. The results were analyzed and compared, so that from the results it\'s possible to evaluate the solutions and applied techniques related to thermal and illumination aspects, thus contributing in the development of design techniques. The objective with these techniques is obtaining environmental comfort and reduction in energy consumption in buildings with the same pattern of use, which is seen to be repeated a lot of times in buildings for administrative use, offices and schools.
188

Diretrizes projetuais para humanização hospitalar: Hospital de Clínicas da Universidade Federal do Triângulo Mineiro / Design guidelines for hospital humanization: teaching hospital of the Triângulo Mineiro Federal University

Mariana Ferreira Martins Garcia 04 March 2016 (has links)
O Hospital de Clínicas da Universidade Federal do Triângulo Mineiro (HC UFTM) foi inaugurado em 1982 na cidade de Uberaba - MG e é, atualmente, o único hospital público do Triângulo Mineiro que oferece atendimento terceirizado de alta complexidade. Os critérios técnicos exigidos em normas rígidas para esses ambientes hospitalares dificultam o processo de humanização hospitalar como forma de atender os usuários satisfatoriamente e proporcionar espaços apropriados para o exercício dos profissionais da saúde e para auxiliar na cura dos pacientes. Sendo assim, o objetivo deste trabalho é propor diretrizes projetuais com a finalidade de melhorar o desempenho térmico e lumínico das alas de clínicas médica (CM) e cirúrgica (CC) do HC da UFTM. Para isso, a metodologia proposta consiste, inicialmente, num levantamento de dados dos aspectos projetuais e construtivos das alas estudadas. Posteriormente, foi feito um levantamento bioclimático de Uberaba dos últimos 10 anos junto a uma caracterização do edifício através dos cálculos das propriedades térmicas dos materiais e do uso das estratégias passivas no projeto. Para verificar a eficiência destas estratégias realizaram-se as análises dos métodos de Mahoney e Givoni. Além disso, o desempenho térmico e lumínico das alas de CM e CC foi analisado através das medições das temperaturas internas e externas, da umidade relativa do ar e dos níveis de iluminância. Depois, foram comparados com as recomendações de Mahoney e Givoni e à norma de iluminação NBR 8995-1. Os resultados encontrados indicaram que das estratégias passivas, a ventilação é a mais favorecida pela implantação do edifício, mas o resfriamento evaporativo e a alta inércia térmica não estão presentes. Além disso, os cálculos das 2 propriedades térmicas dos fechamentos verticais e horizontais e as medições das variáveis ambientais não apresentaram índices ideais de conforto e sim, altas transmitâncias, baixas inércias térmicas e, consequentemente, altas temperaturas no interior das alas, gerando um grande desconforto térmico praticamente o tempo todo. Além disso, os níveis de iluminância encontrados não estão adequados às normativas e, aliados a ambientes sem identidade visual desfavorecem ainda mais a percepção que os usuários/pacientes têm dos mesmos. Promover espaços ajardinados, melhorar o desempenho dos fechamentos através da utilização de isolantes térmicos e rever a concepção visual e os níveis mínimos de iluminação do HC são possibilidades eficientes e utilizadas em diversos hospitais para melhorar o conforto térmico e visual dos pacientes durante suas internações e assegurar qualidade no desempenho das tarefas dos funcionários. / In 1982, the teaching hospital (Hospital de Clínicas - HC) of the Triângulo Mineiro Federal University (UFTM) was opened in Uberaba, in Minas Gerais state in Brazil. Currently, it is the only public hospital in the Triângulo Mineiro area to offer third party high complexity services. Technical requirements in strict regulations for hospital environments make it harder to humanize them and satisfactorily assist users, provide health professionals with adequate working spaces and help the healing process. Therefore, this document aims to propose design guidelines to improve thermal and lighting performance in the medical clinic (clínica médica CM) and surgery clinic (clínica cirúrgica - CC) wings of the HC of UFTM. In order to achieve this, there was initially some data collection regarding design and building aspects related to the aforementioned hospital wings. Afterwards, it was necessary to gather data on the bioclimatic profile of Uberaba for the last ten years and relate it to the building using an estimate of the thermal properties of its materials and of the use of passive strategies in its design. To verify how effective the plans were, analyses based on Mahoney and Givonis methods were carried out. Furthermore, measurement of internal and external temperatures, of relative humidity and of illuminance levels were used to analyze thermal and visual performance of CM and CC wings. Then, the results were compared to Mahoney and Givonis recommendations and to lighting regulation NBR 8995-1. These results showed that regarding passive strategies, ventilation benefits the most from the building orientation, while evaporative cooling and high thermal inertia are absent. Moreover, thermal property figures of the vertical and the horizontal openings and measurements of environmental variables did 4 not present ideal comfort ratings, but high transmittance, low thermal inertia and, consequently, high temperatures inside the wings creating great thermal discomfort almost all the time. In addition, illuminance levels registered did not comply with regulations and, while associated with a lack of visual identity in rooms, caused users/patients to negatively perceive those rooms. Fostering green areas, improving insulation by using thermal insulation materials and revising the visual concept and the minimum illuminance levels in the HC are effective possibilities used in several hospitals to improve patients thermal and visual comfort while under treatment and to ensure quality to staff performance.
189

O conforto térmico nas residências de Rino Levi / The thermal comfort in the residences of Rino Levi

Marina Silva Rahal 05 May 2006 (has links)
Esta pesquisa avalia o conforto térmico das residências projetadas pelo arquiteto Rino Levi, um dos protagonistas da arquitetura moderna brasileira, que se caracterizam pela presença de jardins integrados aos ambientes internos. As sete obras residenciais estudadas localizam-se em regiões diferentes do território brasileiro e apresentam soluções para o condicionamento térmico de acordo com as exigências climáticas do local, tais como elementos de proteção solar, dispositivos para ventilação cruzada ou instalação de calefação. O objetivo deste trabalho é identificar e analisar as soluções arquitetônicas desenvolvidas para garantir o conforto térmico nestas residências. A análise é feita a partir das recomendações construtivas referentes à insolação e ventilação, elaboradas na mesma época em que as casas foram projetadas, e complementada pelas diretrizes construtivas indicadas na norma brasileira atual de desempenho térmico. Verifica-se que a maior parte das soluções projetuais desenvolvidas por Rino Levi para estas casas estão de acordo com as recomendações construtivas da época, bem como as atuais, no tocante ao conforto térmico / This research evaluates the thermal comfort of the residences projected by Rino Levi, one of the Brazilian modern architecture’s protagonists. These houses are characterized by the presence of gardens integrated with the internal spaces. The seven residences studied are located in different regions of Brazilian territory, and present different solutions for thermal performance, according to the exigencies of local climate, like shading elements, crossing ventilations devices or calefaction. This work intends to identify the architectural solutions developed to guarantee thermal comfort in these residences. The analysis is made based on constructive recommendations about solar radiation and ventilation elaborated when these houses were projected and the constructive directress indicated by actual Brazilian norm about thermal performance. The efficiency of most of constructive solution developed by Rino Levi for these residences concerning thermal comfort is verified
190

Qualification expérimentale des performances d'un dispositif de bardage avec lame d'air tampon et parement en bois

Mitogo Eseng, Jesus Nvé 13 March 2012 (has links)
Aujourd’hui à de nombreuses études sur la thermique du bâtiment pour réduire la consommation d’énergie tout en préservant le confort des usagers sont proposées. Le travail présenté ici met en avant les performances d’une technique d’isolation active par un dispositif de bardage extérieur de ce fait soumis au rayonnement solaire incident. L’étude expérimentale mise en oeuvre a permis de caractériser les échanges thermiques à l’intérieur de la lame d’air verticale (circulante ou non circulante), qui sont la clef de ce type de dispositif, en fonction des différents paramètres retenus comme pertinents. Le terme moteur est bien évidemment l’éclairement solaire. La distance parement extérieur mur support, i.e. l’épaisseur de la lame d’air, conditionne un rapport d’aspect et influe donc sur la vitesse de l’air circulant ou sur le volume tampon en situation non circulante et donc sur les échanges thermiques. Enfin les caractéristiques thermiques du parement extérieur, ici une lame de pin maritime ou un bois aggloméré, impactent assez fortement sur l’évolution temporelle des différentes. Une modélisation globale du comportement de la cheminée solaire que constitue le bardageet quelques simulations numériques ont permis de conforter ces différents résultats expérimentaux. On retiendra qu’en été, la solution optimale est un dispositif de bardage avec peu d’inertie thermique et un écoulement d’air rapide alors qu’en hiver, un dispositif avec inertie et sans écoulement contribue à assurer un bon volant thermique. / Today many studies on thermal building to reduce energy consumption while maintaining user comfort are proposed. The work presented here highlights the performance of an active isolation technique by means of exterior cladding thus subjected to solar radiation.The experimental study has been used to characterize the heat transfers inside the vertical cavity (air circulating or not), which are the key to this type of device, depending on various parameter staken as relevant. The driving factor is of course the solar irradiance. The thickness of the air gap induces an aspect ratio and thus affects the speed of the air flowing or the buffer volume and therefore the heat exchanges. Finally, the thermal characteristics of the cladding here maritime pine or chipboard, impact quite strongly on the temporal evolution of the different temperatures.The cladding and the vertical cavity act as a solar chimney, a global modeling of its behavior and some numerical simulations have strengthened the experimental results. We note that in summer, the optimal solution is a device of cladding with little thermal mass an drapid air flow while in winter, a device with large thermal mass and without flow helps to ensure a good thermal flywheel.

Page generated in 0.0314 seconds