• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 140
  • 32
  • 30
  • 28
  • 19
  • 8
  • 8
  • 4
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • Tagged with
  • 321
  • 321
  • 166
  • 132
  • 108
  • 106
  • 67
  • 62
  • 61
  • 45
  • 45
  • 34
  • 31
  • 30
  • 30
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
221

Thermodynamics of Distributed Solar Thermal Power Systems with Storage

Garg, Pardeep January 2015 (has links) (PDF)
Distributed power generation through renewable sources of energy has the potential of meeting the challenge of providing electricity access to the off-grid population, estimated to be around 1.2 billion residing across the globe with 300 million in India, in a sustainable way. Technological solutions developed around these energy challenges often involve thermal systems that convert heat available from sources like solar, biomass, geothermal or unused industrial processes into electricity. Conventional steam based thermodynamic cycle at distributed scale (< 1 MWe) suffers from low efficiency driving scientific research to develop new, scalable, efficient and economically viable power cycles. This PhD work conducts one such study which provides a database of thermal power blocks optimized for the lowest initial investment cost to developers of distributed power plants. The work is divided in two steps; a) feasibility study of various thermodynamic cycles for distributed power generation covering different operating temperature regimes and b) perform their detailed thermo-economic modelling for the heat sources mentioned above. Thermodynamic cycles are classified into three temperature domains namely, low (< 450 K), medium (< 600 K) and high (< 1000 K) T cycles. Any fluid whose triple point temperature is below the typical ambient temperatures is a potential working fluid in the power cycle. Most of the organic and the inorganic fluids satisfy this criterion and can be perceived as potential power cycle fluids. The general notion is that organic fluids are more suited for low or medium temperature cycles whereas inorganic fluids for high temperature ones. Organic fluids can further be classified into hydrofluorocarbon and hydrocarbon. While the former has high global warming potential (GWP), the latter is flammable in nature. Their mixture in certain compositions is found to obviate both the demerits and perform equally well on thermodynamic scales for low T cycles. On the similar lines, mixture of HCs and inorganic fluids, such as propane+CO2 and isopentane+CO2 are found to be more appropriate for medium T applications if the issues like pinch temperature in the regenerator arising due to temperature glide are taken care of. In the high temperature domain, high efficiency Brayton cycle (supercritical CO2) and transcritical condensing cycles are studied with the latter being 2 % more efficient than the former. However, application of the condensing cycle is limited to low temperature ambient locations owing to low critical temperature of CO2 (304 K). In the same cycle configuration, mixture of CO2 and propane (52 and 48%) with a critical temperature of ~ 320 K is observed to retain the thermodynamic performance with the increased heat rejection temperature matched to the tropical ambient conditions. However, these cycles are plagued by the high operating pressures (~300 bar) calling for high temperature steel making the power block uneconomical. In this regard, the advanced CO2 cycles are developed wherein the optimum operating pressures are limited to 150 bar with an increased cycle efficiency of 6 % over the S-CO2 cycle. Feasibility study carried out on these cycles in the Indian context indicates the low and medium T cycles to be better suited for distributed power generation over the high T cycles. In the second part of work, a comprehensive study is performed to optimize the low and the medium T cycles on a thermo-economic basis for the minimum specific investment cost ($/We). Such a study involves development of component level models which are then integrated to form the system of interest, thus, following a bottom-up approach. A major emphasis is given on the development of scroll expander and low cost pebble bed thermal energy storage system that are the reported in the literature as the areas with high uncertainties while connecting them to the system. Subsequently, the key design parameters influencing the specific cost of power from an air-cooled ORC are identified and used to formulate a 7-dimensional space to search for the minimum costs for applications with a) geothermal/waste or biogas heat sources and b) solar ORCs. Corresponding maps of operating parameters are generated to facilitate distributed power engineers in the design of economic systems within constraints such as available heat source temperatures, maximum expander inlet pressures imposed, etc. Further, the effect of power scaling on these specific costs is evaluated for ORC capacities between 5 and 500 kWe.
222

Stockage d'électricité associant un cycle thermodynamique à haut rendement avec un stockage thermique à haute température / Electricity storage system combining a high efficiency thermodynamic cycle with a high temperature thermal storage

Attonaty, Kévin 25 October 2018 (has links)
Cette étude concerne un système de stockage d’électricité basé sur le stockage thermique. Le principe est de convertir de l’électricité issue d’énergies renouvelables en chaleur lorsque la production est supérieure à la demande, de conserver cette chaleur puis de la reconvertir en électricité lorsqu’un besoin se présente. Le système proposé s’appuie sur une technologie de stockage sensible à haute température : le stockage régénératif gaz/solide. Ce stockage est associé à une boucle de charge et à un cycle thermodynamique de restitution électrique. Dans cette étude, deux architectures sont étudiées pour ce dernier : la première est basée sur un cycle gaz, la seconde sur un cycle combiné Joule/Rankine. Un modèle global du système est développé sur la base d’une modélisation de chaque composant à un niveau de détail approprié. Sur la base de ce modèle, une analyse thermodynamique est menée. Celle-ci identifie le rendement exergétique global du procédé, proche de celui d’un cycle à combustion. Une analyse exergétique détaillée du stockage identifie les principaux postes d’irréversibilités dans ce composant. Elle montre qu’il est possible d’optimiser de manière relativement simple ses performances en jouant sur son dimensionnement. Par la suite, une analyse économique montre qu’en dépit de ses performances inférieures, le cycle gaz est associé à des coûts d’investissement limités qui rendent son utilisation pertinente. En termes de coût du stockage, le système étudié est compétitif avec des solutions comme les batteries. / This study concerns an electricity storage system based on thermal energy storage. Its overall purpose is to convert electricity produced by renewable energies into heat when the supply exceeds the demand. This heat is stored for a few hours and converted back to electricity when there is a need for it. The proposed system relies on a high temperature sensible thermal energy storage technology known as the gas/solid packed bed thermal storage. This storage comes with a charging loop and a thermodynamic cycle to carry out the heat to electricity conversion. In this study, two main architectures are considered for this cycle: a simple gas cycle and a Joule/Rankine combined cycle. Each component is modeled with an appropriate level of detail in order to create a global model of the system. This model is used to carry out a thermodynamic analysis. This study calculates the global exergy efficiency of the whole process, which is close to exergy efficiency of a combustion cycle. A detailed exergy analysis of the storage allows to identify the main phenomena behind the availability losses of this component. It shows that it is possible to increase the efficiency of the storage by modifying its sizing. Apart from this study, an economic analysis shows that regardless of its low energy and exergy efficiencies, the gas cycle comes with limited investment costs which insure an interesting profitability. In terms of storage cost, the proposed system is close to other electricity storage solutions like batteries.
223

Combinaisons huiles/solides pour le stockage thermocline : De l’étude des matériaux au modèle de stockage thermique / Oils/solids combinations for thermocline storage : From materials to storage modelling

Molina, Sophie 19 September 2018 (has links)
Ces dernières décennies ont vu le développement exponentiel des technologies de stockage, du fait des contraintes de plus en plus fortes sur le secteur énergétique et les ressources fossiles, suscitant un intérêt croissant de la part des chercheurs et des industriels. Ces technologies trouvent en effet de multiples applications, par exemple en combinaison avec des sources d’énergie renouvelable pour pallier leur intermittence, ou en récupération de chaleur fatale sur les procédés industriels. De nombreux concepts ont été développés à ce jour, et parmi eux la solution thermocline dual-media, qui consiste à stocker l’énergie sous forme thermique dans un réservoir contenant le mélange d’un fluide et d’une matrice solide.C’est sur cette technologie que s’est focalisé le projet Therm’Stock, porté par le groupe CNIM et soutenu par les Investissements d’Avenir de l’ADEME. Ce projet, débuté en 2015, associe cette entreprise à trois laboratoires, dont le Laboratoire de Thermique Energétique et Procédés (LaTEP) de l’Université de Pau et des Pays de l’Adour. La contribution du LaTEP dans le projet a été centrée sur l’étude des matériaux de stockage à utiliser pour le système thermocline envisagé, avec un focus sur les huiles thermiques comme fluide caloporteur.Dans un premier temps, un recensement des huiles disponibles commercialement a été réalisé, afin de sélectionner les fluides répondant aux contraintes du projet Therm’Stock, et notamment à la gamme de température de fonctionnement visée. Les huiles sélectionnées ont ensuite été caractérisées à l’aide du matériel disponible au laboratoire, afin de définir un ordre de priorité pour leur étude. L’huile Jarytherm® DBT s’étant démarquée, c’est ce fluide qui a été choisi pour la suite des analyses.Ces analyses ont porté sur deux aspects d’intérêt pour le stockage thermocline dual-media : le vieillissement du fluide caloporteur, et sa compatibilité avec le matériau de stockage solide. Les études réalisées ont permis d’évaluer l’influence de différents paramètres sur le vieillissement de l’huile (température, durée), ainsi que sa compatibilité avec plusieurs familles de matériaux. Au total, ce sont 15 combinaisons huiles/solides qui ont été testées, sur 18 campagnes d’essai.Deux matériaux solides ont montré une compatibilité intéressante avec l’huile Jarytherm® DBT : l’acier et le verre soda-lime. Afin de compléter l’étude réalisée au laboratoire, ces deux combinaisons ont été introduites et testées dans un pilote de stockage thermocline dual-media, développé et exploité par Bertin Technologies, filiale du groupe CNIM. Certains des résultats obtenus ont été communiqués au LaTEP, et ont permis une étude à échelle pilote des performances du stockage avec les matériaux sélectionnés. Cette analyse a par la suite été complétée par une étude numérique, au travers du développement d’un modèle spécifique de stockage thermique. L’utilisation de ce modèle a permis de confirmer et d’étendre les résultats expérimentaux obtenus sur le pilote de Bertin Technologies, mais également d’intégrer les données de vieillissement générées sur le banc d’essai du laboratoire. / These last decades, stronger constraints on the energy sector and fossil sources depletion have pushed towards an increased development of storage technologies, which benefited from a renewed interest from researchers and industrialists. These technologies can be implemented in various applications, for example in combination with renewable energy sources or for waste heat recovery in industrial processes. Several concepts have been developed so far, and among them the dual-media thermocline, which consists in storing thermal energy in a single tank, containing a fluid in direct contact with a solid matrix.Therm’Stock project, led by the CNIM group and supported by the “Investissements d’Avenir” program from ADEME, has focused on this dual-media thermocline system. This project started in 2015, gathering the leading company and three laboratories, including the Laboratory for Thermal, Energy and Process engineering (LaTEP) from the University of Pau (UPPA). LaTEP contribution to the project has been focused on storage material selection and characterization, and more particularly on thermal oils as heat transfer fluids.The study began with a screening of commercial thermal oils, in order to select the ones that could match the constraints linked to Therm’Stock project, and especially the temperature range chosen, between 100 and 350°C. The identified oils have then been characterized using the devices available at LaTEP, to define a priority order for their evaluation for thermal storage. Jarytherm® DBT oil showed promising properties, and this fluid was chosen for the following analyses.These analyses focused on two main aspects, of interest for dual-media thermocline systems: oil ageing, and its compatibility with solid storage medium. The influence of temperature and time on oil ageing has been evaluated, along with the importance of the solid in direct contact with the fluid. In total, 15 oils/solids combinations have been considered, with 18 test campaigns. Two solids have shown promising compatibility with Jarytherm® DBT oil: steel and soda-lime glass. In order to complete the laboratory-scale tests, these two combinations have been introduced and tested in a pilot-scale dual-media thermocline, developed and exploited by Bertin Technologies, a CNIM group affiliate. Some of these experimental data have been shared with LaTEP, and allowed for a pilot-scale study of storage performance with the selected materials. This analysis was then complemented by a numerical study, through the development of a specific one-dimensional storage model. Using this model, experimental data generated on Bertin Technologies pilot could be confirmed and extended. Integrating data from laboratory-scale ageing tests, the influence of heat transfer fluid degradation on storage performance has also been evaluated.
224

Modélisation dynamique d’un dispositif de stockage par chaleur sensible intégré à un système énergétique / Dynamic modeling of a sensible heat storage device integrated into an energy system

Terzibachian, Elie 10 July 2017 (has links)
Dans les années récentes, des politiques visant à promouvoir l’efficacité énergétique ont été instaurées en réponse aux obligations réglementaires européennes et internationales. Le stockage d’énergie thermique s’est révélé être une technologie qui permet une amélioration de l’efficacité énergétique, en particulier celle des installations techniques pour le conditionnement d’air, le chauffage et l’eau chaude sanitaire pour le bâtiment. Parmi les différents types existants, le stockage thermique par chaleur sensible est le plus ancien et le plus répandu sur le marché. Or, l’intégration du ballon de stockage dans les installations énergétiques s’avère délicate tant dans la phase de conception que de l’exploitation de ces installations. Par ailleurs, il convient d’évaluer – pour les systèmes et équipements techniques du bâtiment – leurs consommations énergétiques annuelles (ou saisonnières). Pour répondre à l’ensemble de ces exigences, le recours à la modélisation et simulation dynamique des composants et systèmes énergétiques devient indispensable. Le travail de la présente thèse présente une approche de modélisation et de simulation dynamique d’un ballon de stockage d’eau par chaleur sensible qui répond aux contraintes particulières suivantes : assurer une modélisation fine à partir de la résolution des équations de Navier-Stokes d’un composant – le ballon de stockage – dans lesquels les mécanismes de transfert et d’écoulement sont complexes et réaliser une modélisation dynamique d’un système thermique associant des divers composants techniques d’un circuit et ceci avec des temps de calcul raisonnables, compatibles avec les pratiques courantes des bureaux d’étude spécialisés en conception d’installations . Le travail réalisé associe donc une analyse fine du comportement dynamique du ballon grâce au développement d’un modèle CFD, la détermination d’un modèle réduit à partir de ce modèle – qui permet la construction d’un champ dynamique de température – et enfin une modélisation sous Modelica adaptée à la simulation d’un système énergétique complexe. Dans les différentes phases de cette étude, les résultats issus de la simulation sont alors confrontés aux résultats déduits de divers travaux expérimentaux. La validation de la démarche suite à cette confrontation calculs/expériences permet d’envisager l’application des outils présentés à des projets techniques notamment au projet « PV cooling » de climatisation des bâtiments avec une ressource solaire photovoltaïque, projet réalisé en parallèle de ce projet de thèse et porté par les acteurs industriels qui soutiennent cette recherche. / In recent years, policies to promote energy efficiency have been introduced in response to European and International regulatory obligations. Thermal Energy Storage has proven to be a technology that improves energy efficiency, particularly for the air conditioning, heating and domestic hot water utilities in buildings. Among the existing types, sensible heat storage is the oldest and most widespread on the market. The integration of the storage tank into energy installations may be tricky in both the design and operation phases of these installations. Moreover, the annual (or seasonal) energy consumption of the building's technical systems and equipment should be evaluated. To meet all these requirements, dynamic modeling and simulation of energy components and systems becomes essential. The work of this thesis presents a dynamic modeling and simulation approach of a sensible heat water storage tank which respond to the following particular constraints: To ensure a fine modeling based on the resolution of the Navier-Stokes equations of a component – the storage tank – in which the flow and transfer mechanisms are complex, and to carry out a dynamic modeling and simulation, with reasonable computational time, of a thermal energy system associating various technical components of a circuit and compatible with the usual practices of the specialized system design offices. Thus, the carried out work combines a detailed analysis of the dynamic behavior of the storage tank through the development of a CFD model, the development of a reduced model from the previous CFD model that allows the construction of temperature dynamic fields and finally a Modelica modeling adapted to the simulation of a complex energy system. In the different phases of this study, the results from the simulation are compared to the results deduced from various experimental works. The validation of the approach following this comparison between calculations and experimental results makes it possible to consider the application, of the presented tools, in technical projects and in particular the project “PV cooling” for buildings air conditioning with a photovoltaic solar resource, a project that is carried out in parallel with this thesis by the industrial players supporting this research.
225

Développement d’un procédé de stockage d’énergie thermique haute température par voie thermochimique / Development of a high temperature thermochemical heat energy storage process

Pardo, Pierre 09 December 2013 (has links)
Les travaux présentés dans cette thèse concernent le développement d’un procédé de stockage d’énergie thermique haute température par voie thermochimique en vue d’une application dans une centrale solaire à concentration. Un état de l’art des technologies de stockage d’énergie thermique haute température par voie thermochimique a permis de définir le couple réactionnel et la technologie les mieux adaptés au procédé. Ainsi, la réaction réversible Ca(OH)2(s) = CaO(s) + H2O(g) est mise en oeuvre dans un réacteur à lit fluidisé. Une étude expérimentale a permis de démontrer la faisabilité du procédé en stockant et en déstockant l’énergie à une même température et en mettant en oeuvre 50 cycles de charge/décharge de l’énergie sans perte de réversibilité. L’utilisation d’un modèle monodimensionnel couplant les phénomènes chimiques, thermiques et hydrodynamiques à l’intérieur du réacteur a permis de mettre en évidence l’influence des conditions opératoires sur les performances du système. Les premiers pas vers une extrapolation industrielle font l’objet de la dernière partie de ces travaux, en présentant l’analyse énergétique d’une centrale solaire à concentration intégrant le procédé de stockage développé et en présentant une étude expérimentale mettant en oeuvre un solide de type industriel dans le réacteur. / This PhD thesis concerns the development of a high temperature thermochemical heat energy storage process for an application in concentrated solar power plants. A literature review allows the identification of both the best reaction couple and technology to operate the process. Thus, the Ca(OH)2(s) = CaO(s) + H2O(g) reversible reaction is carried out in a fluidized bed reactor. The experimental study demonstrated the process feasibility. Thermal energy has been charged and discharged at the same temperature and 50 cycles have been performed without any loss of reversibility. A 1D model coupling the chemical, thermal and hydrodynamic phenomena inside the reactor has been developed to study the operating parameter effects on the process performance. The last section of this work deals with the first steps towards an industrial scale-up. An energetic analysis of a concentrated solar power plant integrating the developed storage process is detailed as well as the reactions implementation with an industrial solid.
226

Stockage massif d'électricité sous forme thermique / Large scale Thermal Energy Storage of Electricity

Desrues, Tristan 28 June 2011 (has links)
Les travaux présentés dans cette thèse concernent un nouveau procédé de stockage d'électricité à échelle industrielle, sous forme de stockage de chaleur sensible. La chaleur est stockée dans deux échangeurs gaz-solide de grande taille appelés régénérateurs qui sont reliés à une paire de turbomachines (compresseur et turbine) formant ainsi un cycle thermodynamique. Selon le sens d'écoulement du fluide caloporteur, ce cycle est de type « pompe à chaleur » en stockage ou « moteur thermique » en déstockage. La modélisation complète du procédé a permis de caractériser son comportement dans un cas industriel, et de mettre en évidence les tendances principales du système. Les performances prévues se rapprochent de celles des installations existantes les plus adaptées au stockage massif d'électricité, telles que le stockage hydraulique gravitaire. Une étude CFD a permis l'optimisation d'une géométrie de canal à obstacles destinée à intensifier l'échange thermique dans les régénérateurs et qui sera testée expérimentalement à la suite de cette thèse. Les préparatifs de cette expérience sont abordés et ses objectifs sont explicités. / Les travaux présentés dans cette thèse concernent un nouveau procédé de stockage d'électricité à échelle industrielle, sous forme de stockage de chaleur sensible. La chaleur est stockée dans deux échangeurs gaz-solide de grande taille appelés régénérateurs qui sont reliés à une paire de turbomachines (compresseur et turbine) formant ainsi un cycle thermodynamique. Selon le sens d'écoulement du fluide caloporteur, ce cycle est de type « pompe à chaleur » en stockage ou « moteur thermique » en déstockage. La modélisation complète du procédé a permis de caractériser son comportement dans un cas industriel, et de mettre en évidence les tendances principales du système. Les performances prévues se rapprochent de celles des installations existantes les plus adaptées au stockage massif d'électricité, telles que le stockage hydraulique gravitaire. Une étude CFD a permis l'optimisation d'une géométrie de canal à obstacles destinée à intensifier l'échange thermique dans les régénérateurs et qui sera testée expérimentalement à la suite de cette thèse. Les préparatifs de cette expérience sont abordés et ses objectifs sont explicités.
227

Otimização de um sistema de aquecimento de água com mangueira de polietileno: estudo de caso / Optimization of a water heating system with polyethylene hose: case study

Queiroz, José Aparecido Silva de [UNESP] 29 April 2016 (has links)
Submitted by JOSÉ APARECIDO SILVA DE QUEIROZ null (jqueiroz@unilins.edu.br) on 2016-06-28T17:33:24Z No. of bitstreams: 1 TESE FINAL JOSÉ QUEIROZ.pdf: 1990890 bytes, checksum: 8dbd46996efdf66f13c164f994bd6087 (MD5) / Approved for entry into archive by Juliano Benedito Ferreira (julianoferreira@reitoria.unesp.br) on 2016-06-29T20:20:08Z (GMT) No. of bitstreams: 1 queiroz_jas_dr_bot.pdf: 1990890 bytes, checksum: 8dbd46996efdf66f13c164f994bd6087 (MD5) / Made available in DSpace on 2016-06-29T20:20:08Z (GMT). No. of bitstreams: 1 queiroz_jas_dr_bot.pdf: 1990890 bytes, checksum: 8dbd46996efdf66f13c164f994bd6087 (MD5) Previous issue date: 2016-04-29 / O principal objetivo deste estudo é avaliar, com bases em resultados experimentais, um sistema de aquecimento solar constituído de mangueira de polietileno que permite a transferência do calor gerado pela radiação solar direta e/ou difusa (Energia Solar Térmica) para a água. O sistema foi dimensionado para atender a demanda de um Centro de Ressocialização com capacidade para 220 internos. Justifica-se a escolha do tema pelo fato de que consiste em um assunto atual de grande relevância, principalmente porque vive-se uma crise energética em nível mundial. O estudo comprova através de um experimento a viabilidade do aquecedor solar de baixo custo, considerando-se sua aplicabilidade em locais que demanda grande volume de água aquecida para banho. Os resultados demonstraram que o sistema alternativo proposto atendeu de forma eficiente e econômica a demanda solicitada, o que pode ser adotada pelo poder público em qualquer um de seus segmentos que necessite de água aquecida, com objetivo de reduzir custos e contribuir com o sistema energético brasileiro. O sistema foi analisado para atuar em fluxo continuo e fluxo intermitente, ambos objetivando aquecer a água a temperaturas superiores a 37 °C no inverno. Os resultados alcançados atenderam as expectativas coletando grandes volumes, com temperaturas médias acima de 42 °C. / The aim of this study is to evaluate, with bases on experimental results, a solar heating system consists of polyethylene hose that allows the transfer of heat generated by direct solar radiation and / or diffuse (Solar Thermal Energy) to the water. The system has been designed to meet the demand of a Rehabilitation Center with a capacity for 220 inmates. Justified the choice of the theme for the fact that consists of a current subject of great importance, especially because it lives in an energy crisis worldwide. The study proves through an experiment the viability of solar heater low cost, considering their applicability in places that demand large volume of heated water for bathing. The results showed that the alternative system proposed met efficiently and economically the requested demand, which can be adopted by the government in any of its segments that need heated water, in order to reduce costs and contribute to the Brazilian energy system. The system was analyzed to operate in continuous flow, intermittent flow, both aiming at heating the water to temperatures above 37 °C in winter. The results achieved met the expectations collecting large volumes, with average temperatures above 42 °C.
228

Etude du confort thermique dans l'habitat par des procédés géo-héliothermiques / Study of the thermal comfort in building by geo- solar thermal processes

Benzaama, Mohammed Hichem 14 May 2017 (has links)
Ce travail s'inscrit dans le cadre de la recherche des solutions d’économie d'énergie du bâtiment tout en utilisant des sources naturelles et renouvelables (Energie solaire pour le chauffage et la géothermie pour le rafraîchissement). Il est nul besoin de rappeler que l'Algérie dispose d'un potentiel énergétique hélio géothermique important. Dans ce travail de thèse on s'intéresse particulièrement à l'étude du confort thermique (hiver et été) dans l'habitat alimenté par un plancher hydraulique réversible. Pour mener à bien cette étude, nous disposons d'un gisement solaire important d'une part et d'autre part d'un dispositif expérimental à échelle réelle. Une pièce munie d'un plancher hydraulique réversible (chauffant ou rafraichissant) est instrumentée. Une citerne de stockage enfuie à quelques mètres de la surface du sol afin de bénéficier du rafraichissement géothermique. Un service d'asservissement permettant la régulation du système en fonctionnement mode chauffage ou mode rafraichissement. Plusieurs sondes de mesures reliées à une station d'acquisition qui est reliée à un ordinateur permettent le suivi des évolutions de températures. La modélisation de la structure de l'enveloppe de la cellule et l'évolution de la température de l'air intérieur et celle des parois sont réalisées sous le logiciel TRNSYS. A l'aide des résultats obtenus par TRNSYS, logiciel FLUENT nous a permis de modéliser la tache solaire et son influence sur le plancher chauffant sous les conditions climatiques de la ville d'Oran.Après validation, la simulation numérique est utilisée pour étudier le comportement thermique de la cellule, les performances énergétiques du plancher réversible et le calcul des économies d'énergie que l'on pourrait réaliser avec de tels systèmes. / This work is part of the search for energy saving solutions in the building industry while using natural and renewable sources, such as solar energy for heating and geothermal energy for refreshment. There is no need to recall that Algeria has a very large geothermal gravitational energy potential in view of its geographical position.In this thesis work, we are particularly interested in the study of thermal comfort in the case of a housing powered with a reversible hydraulic floor (heating and cooling).To carry out this study, as we can see Algeria have an important solar field and on the other hand we use an experimental system representing a real scale local. To do this, a room with a reversible hydraulic floor (heated or refreshing) is instrumented. A storage tank buried in the ground at few meters from the ground surface is used for thegeothermal refreshment during the warm periods. A service system allows us to regulate the system in heating or cooling mode. Several measuring probes used are connected to an acquisition station which is connected to a computer for monitoring of temperature évolutions.The modeling of the structure of the cell envelope is carried out under the TRNSYS software. With this, we have access to evolutions of the temperatures of the indoor air and to that of the walls. These results obtained by TRNSYS are used in a second step as input data for the FLUENT software. This allows us to model the solar spot and its influence on the heating floor under the climatic conditions of the city of Oran.After validation, numerical simulation is used to study the thermal behavior of the cell, the energy performance of the reversible floor and the calculation of the energy savings that could be achieved with such systems.
229

Métodos analí­ticos para o cálculo de desempenho de motores termomagnéticos do tipo tesla. / Analytical methods for the performance calculation of tesla type thermomagnetic motors.

Carlos Vinicius Xavier Bessa 08 June 2018 (has links)
Motores termomagnéticos são dispositivos capazes de converter calor em energia mecânica através do efeito termomagnético, e são uma alternativa para a conversão de energia de rejeitos térmicos de baixa e baixíssima qualidade. Neste trabalho é proposta uma classificação dos motores termomagnéticos como sendo de dois tipos, os motores tipo Edison e os motores tipo Tesla. Feita a classificação, diferenciou-se o comportamento de operação e os ciclos termodinâmicos desenvolvidos pelos dois tipos de motores, mostrando que motores do tipo Tesla desenvolvem um ciclo termodinâmico que pode ser aproximado por um ciclo Brayton magnético, já motores do tipo Edison descrevem um ciclo mais complexo, não podendo ser aproximado por um ciclo Brayton. Compararam-se os parâmetros de interesse para ambos os motores através de análises termodinâmicas, onde se concluiu que motores do tipo Tesla apresentam melhores respostas de trabalho e eficiência que motores do tipo Edison, quando são consideradas as mesmas condições de operação. Além disso, identificou-se que a equação de força de Kelvin é a equação que corretamente descreve o comportamento da força magnética em um motor termomagnético, essa contribuição é importante, pois vários trabalhos publicados na literatura utilizam equações que não descrevem corretamente o comportamento da força magnética. Mostrou-se que o trabalho produzido em um motor termomagnético é igual ao trabalho produzido pela força magnética resultante no dispositivo. Foi desenvolvida e validada uma metodologia para o cálculo do trabalho específico produzido em um motor do tipo Tesla. Utilizando as metodologias validadas, verificou-se como a temperatura, o campo magnético aplicado, o fator de desmagnetização e o tipo de transição influenciam o comportamento dos motores termomagnéticos tipo Tesla, o que abre caminho para o desenvolvimento de dispositivos mais interessantes do ponto de vista termodinâmico. / Thermomagnetic motors are devices capable of converting heat into mechanical energy through the thermomagnetic effect. These devices are able to operate using low or very low quality thermal waste, being an alternative to avail that range of thermal energy. This work classifies the thermomagnetic motors in two types: The Tesla type and the Edison type thermomagnetic motors, differentiating the operational behavior and the thermodynamic cycles developed in each type. By using thermodynamic approaches, it is shown that the Tesla type thermomagnetic motors have best response in terms of work and efficiency than the Edison type thermomagnetic motors, when the same operating conditions are considered. In addition, an experimental approach is presented, proving that the Kelvin force equation describes the behavior of the force in thermomagnetic motors, and the work produced in a motor is the same that the work produced by the resultant magnetic force in the system. It was developed and validated a method to estimate the work produced by cycle in a Tesla type thermomagnetic motor, and using thermodynamic approaches, the relevance of the temperature, applied magnetic field, demagnetizing factor and transition type in the Tesla type thermomagnetic motor were verified.
230

Estudo das características elétricas e microestruturais de supercapacitores para armazenamento de energia / Study of electrical and microstructural characteristics of supercapacitors for energy storage

FERNANDEZ, ANTONIO P.R. 11 November 2016 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2016-11-11T16:52:08Z No. of bitstreams: 0 / Made available in DSpace on 2016-11-11T16:52:08Z (GMT). No. of bitstreams: 0 / Esta dissertação tem por objetivo reportar dados relativos às características elétricas e microestruturais de eletrodos aplicadas em dispositivos armazenadores de energia, especificamente supercapacitores constituídos por eletrodos de carvão ativado. Os parâmetros elétricos estudados foram a resistência em série equivalente obtida pelo método da interrupção de corrente (ESR(Inst)) (sendo que a sigla ESR é oriunda do termo inglês Equivalent Series Resistance), a resistência em paralelo equivalente (EPR(Dep)) obtida pelo método do valor dependente (sendo que a sigla EPR é oriunda do termo inglês Equivalent Parallel Resistance) e a capacitância (C(DC)) obtida pelo método da corrente contínua (sendo que a sigla DC oriunda do termo inglês Direct Current). Tais parâmetros foram escolhidos devido ao impacto que causam no tempo de vida útil, na capacidade de armazenamento de cargas elétricas, na velocidade de carga e descarga, na perda por efeito termoiônico nos processos de carga e descarga e na perda de cargas armazenadas devido à autodescarga em supercapacitores. Os dados microestruturais reportam por meio de imagens a homogeneidade da porosidade e por meio de valores correlacionados a composição química e eventuais contaminações presentes nos eletrodos. Os dados e valores coletados possuem a intenção de servir como referência comparativa de qualidade e apontar qual parâmetro afeta mais a qualidade do supercapacitor. Para tanto foram realizados testes a fim de coletar valores de C(DC), ESR(Inst) e EPR(Dep) após a exposição de supercapacitores de 1F/5,5V a temperaturas de 50ºC, 75ºC, 100ºC e 125ºC por 672 horas, sendo os dados coletados ao inicio dos testes, à temperatura ambiente, e posteriormente a cada 168 horas. Feitos os experimentos concluiu-se que o parâmetro que sofreu maior deterioração com o acréscimo de energia térmica foi a EPR(Dep), em seguida a C(DC), que de fato pouco sofreu alteração e a ESR(Inst), em que a mudança dentro do erro de medição foi imperceptível. / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP

Page generated in 0.1796 seconds