• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 240
  • 9
  • 1
  • Tagged with
  • 250
  • 250
  • 249
  • 62
  • 61
  • 28
  • 28
  • 26
  • 25
  • 24
  • 22
  • 22
  • 22
  • 21
  • 21
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

[en] METHODOLOGY FOR DETERMINING THE POTENTIAL MARKET OF A MICROTURBINE BASED COGENERATION SYSTEM FOR ELECTRIC ENERGY AND HOT WATER PRODUCTION / [pt] METODOLOGIA PARA DETERMINAÇÃO DO MERCADO POTENCIAL DE UM SISTEMA DE COGERAÇÃO COM MICROTURBINA PARA PRODUÇÃO DE ENERGIA ELÉTRICA E ÁGUA QUENTE

JOAO VIEIRA DE ARAUJO 11 October 2007 (has links)
[pt] O uso seqüencial de energia elétrica e energia térmica a partir da energia química do mesmo combustível tem sido estudado para melhorar o custo benefício de uma geração distribuída. O objetivo deste estudo é determinar o mercado potencial desta tecnologia na região de influência da concessionária local de energia elétrica. Para alcançar este objetivo, foi necessário avaliar o desempenho de um sistema de cogeração com uma microturbina fornecendo potência elétrica e energia térmica através dos gases de exaustão que aquecem água para o ginásio esportivo da PUC-Rio. O sistema está configurado por uma microturbina, uma caldeira de recuperação, um reservatório térmico (boiler) e uma caixa para alimentação de água fria. Resultados obtidos de testes de curta duração, através de uma metodologia desenvolvida, para a avaliação do desempenho do sistema de cogeração na produção de energia elétrica e térmica, são apresentados. Os testes foram realizados para potências elétricas de 100, 75, 50 e 25 % da carga máxima da microturbina. Em adição, testes para avaliação do desempenho ao longo do tempo em função das variações da carga e das condições ambientais foram estudados. Além disso, através de uma metodologia desenvolvida, mostram-se os resultados nos cálculos de incerteza dos parâmetros analisados. Dados de consumo de energia elétrica em janeiro de 2003, de cerca de 8000 consumidores na área de concessão da LIGHT SESA, em diferentes classes tarifárias, atualizadas para 2007, foram utilizados com a metodologia desenvolvida para estimar o mercado potencial de energia elétrica na região de influência da concessionária local de energia elétrica em 384,5 MW e 20415 MWh/mês, considerando uma taxa interna de retorno mínimo de 15% a.a. Foi mostrado que o elevado custo da microturbina é uma barreira para sua introdução no mercado. Entretanto, a cogeração pode colaborar substancialmente para melhorar o custo benefício. Estas conclusões foram obtidas a partir do tempo de retorno do investimento no sistema pelos consumidores analisados. / [en] The sequential use of electric energy and thermal energy from the chemical energy of the same fuel has been studied to improve the cost benefit of a distributed generation. The objective of this study is to evaluate the potential market of this technology in the region of influence of the local utility of electric energy.utility company (LIGHT). In order to attain this objective, it was necessary to evaluate the performance of a micro turbine based cogeneration system used for supplying electrical and thermal energy to PUC-RIO´S Gymnasium. The system consists of a microturbine, a heat recovery boiler, and a cold water feeding reservoir. The short duration test results are presented for the evaluation of the cogeneration system performance for the production of electric and thermal energy. The tests were carried on for 100, 75, 50 and 25% micro turbine electric energy generation loads. Time performance of the micro turbine was also studied. Moreover, a methodology was shown to calculate the uncertainty of measurements of several performance parameters. The micoturbine marked potential was estimated by analyzing the consumption of about 8000 clients in January 2003, updating the tariffs to 2007, resulting in 384,5 MW and 20415 MWh/month, considering a minimum internal rate of return of investiment of 15% per year, during a 15 year period. It was concluded that the microturbine cost is still a barrier to its market penetration. Cogeneration can be used to improve the cost benefit of the system.
52

[en] METROLOGICAL ASSESSMENT OF FLUORESCENCE SIGNALS OF MEASUREMENTS OF PIGMENTS IN WATER / [pt] AVALIAÇÃO METROLÓGICA DA RESPOSTA DE SINAIS DE FLUORESCÊNCIA PARA MEDIÇÕES DE PIGMENTOS EM ÁGUA

CARLOS EDUARDO DEODORO RODRIGUES 03 April 2008 (has links)
[pt] Objetivo. Fornecer confiabilidade às medições do LIDAR a partir: (i) do estabelecimento de padrões de configuração dos parâmetros do equipamento, na obtenção de sinais de fluorescência para medições de pigmentos em água; (ii) da avaliação de diferentes procedimentos para melhorar a relação sinal-ruído, preservando a integridade das bandas de interesse contidas no espectro de fluorescência; (iii) da verificação da repetitividade do equipamento para medições de comprimentos de onda associados aos máximos do espalhamento Raman da água, da banda de clorofila a, assim como, da banda de matéria orgânica dissolvida (MOD); (iv) e da avaliação da eficiência do processamento desenvolvido para obtenção de concentrações relativas da clorofila a quando comparadas aos resultados correlacionados à concentrações absolutas desse tipo de pigmento. Motivação. Contribuir para o desenvolvimento do monitoramento remoto utilizando um sistema LIDAR, fornecendo parâmetros que possibilitem maior confiabilidade às informações adquiridas pelo sistema. Contextualização. O monitoramento ambiental é uma prática adotada com maior freqüência por inúmeras empresas e instituições com o objetivo de minimizar impactos nocivos ao meio ambiente. O monitoramento remoto é uma ótima alternativa, pois, possibilita um levantamento prévio de possíveis vazamentos de diferentes tipos de poluição, sendo sensível à avaliação de sutis alterações no meio, possibilitando a identificação desses problemas antes mesmo de se tornarem aparentes. Metodologia. A prática adotada na obtenção de êxito dos objetivos apontados baseou-se: (i) na coleta de informação de diferentes modelos de monitoramento remoto, principalmente, utilizando um sistema LIDAR; (ii) na coleta de dados através da experimentação em laboratório e em campo e (iii) no desenvolvimento de processos que possibilitaram a análise das informações contidas nos sinais obtidos. Resultados. Na busca de um sinal-padrão de resposta do equipamento, o trabalho consiste em análises experimentais e no desenvolvimento de processos que auxiliem na análise das informações contidas nos sinais. Dentre os experimentos pode-se destacar duas abordagens: (i) a primeira, no laboratório, a partir de análise de amostras de água pura, que avalia as flutuações do sinal de fluorescência do espalhamento Raman da água para diferentes parâmetros do equipamento; (ii) e uma segunda análise, com dados in vivo, que avalia a concentração relativa de clorofila a para diferentes processos a fim de obter um processo padrão que diminui a sua incerteza na determinação desse quantitativo. Conclusões. O sensoriamento retomo é uma técnica útil para a investigação ambiental, porém, a implantação de práticas que contribuem para o aumento da confiabilidade dos dados fornecidos pelo sistema são igualmente indispensáveis. / [en] Aim. Providing reliability of LIDAR readings of fluorescence signals for measurements of pigments in ocean water by: (i) establishing configuration standards for equipment parameters. (ii) assessing different procedures to improve the signal-tonoise relationship. (iii) preserving the integrity of the wavelength bandwidth of the fluorescence spectrum. (iv) verifying the repeatability of wavelength measurements associated with local maxima of the Raman scattering curve of ocean water and chlorophyll a, as well as organic materials (dissolved in water) bandwidths. (v) and assessing the efficiency of the methodology developed for obtaining relative concentrations of chlorophyll a. Motivation. Contributing to the development of remote monitoring when using the LIDAR technique. This would bring about greater reliability. Context. Over the years environmental surveillance has been adopted by many companies and institutions as an effective practice to minimize harmful impacts on the environment. The remote monitoring is unquestionably a versatile alternative for detecting possible leaking of noxious substances before they become apparent. Methodology. The procedures included: (i) collecting information of different physical models of remote monitoring. (ii) collecting data from experiments carried out in the laboratory and in situ. (iii) and developing a procedure to analyze signal information. Results. Two approaches were adopted when carrying out the experiments: (i) in the laboratory, by evaluating fluorescence signal fluctuations of the Raman scattering in ocean water for different equipment parameters. (ii) and in situ, by measuring the relative concentration of chlorophyll a in ocean water for different schemes in order to choose the standard one. Conclusions. The remote monitoring is a useful tool to carry out environmental surveillance. But to increase the reliability of data collected by the optical-laser system apparatus the introduction of metrological assessment procedures is mandatory.
53

[en] GROUND VEHICLES CONFORMITY ASSESSMENT: METROLOGICAL ANALYSIS AND MODERNIZATION OF A SYSTEM TO MEASUREMENT VELOCITY / [pt] AVALIAÇÃO DA CONFORMIDADE DE VEÍCULOS TERRESTRES: ANÁLISE METROLÓGICA E MODERNIZAÇÃO DE UM SISTEMA PARA MEDIÇÃO DE VELOCIDADE

MARCOS JOSE FERREIRA CARVALHO 25 April 2005 (has links)
[pt] A análise experimental é muito importante para se conhecer as características de Qualquer produto. Os resultados dos testes podem ser usados em pesquisas ou para serem comparados com valores padrões. No segundo caso é necessário seguir certos procedimentos que estão descritos em normas e comparar os valores das características do produto com os requisitos normalizados. No campo da Tecnologia Industrial Básica esta atividade é comumente denominada de avaliação da conformidade. Mas para se medir essas características é necessário usar instrumentos. A instrumentação é a parte mais importante neste processo porque se são usados instrumentos inadequados, o resultado da medição será incorreto e os erros poderão grandes. Então é necessário que os instrumentos tenham sido corretamente calibrados para terem exatidão adequada, baixa incerteza e garantir a repetibilidade e reprodutibilidade das medições. Metrologia é a ciência que trata da confiabilidade das medições. Nos testes veiculares acontece o mesmo, porém é necessário, também, conhecimento sobre a dinâmica veicular, para se saber como e o que será medido. O Campo de Provas da Marambaia do Exército Brasileiro possui um equipamento empregado em avaliação de veículos que mede velocidade e distância usando um sensor óptico sem contato com o solo e um sistema de aquisição de dados. Esta dissertação de mestrado apresenta uma alternativa para a Unidade Central de Processamento deste equipamento substituindo-a por um computador portátil com uma placa de aquisição e um software específico com as ferramentas para processar o sinal do mesmo transdutor óptico. Entretanto isto não é suficiente, é necessário um tratamento metrológico deste sistema de aquisição de dados para garantir a incerteza de medição e evitar os riscos de falso aceito e falso rejeito. No contexto do tratamento metrológico desenvolvido, ambos os sistemas de medição foram avaliados, o sistema originalmente em uso e o sistema alternativo proposto que o substituirá. O conhecimento das incertezas associadas constitui estratégico insumo metrológico para a importante etapa de calibração dos equipamentos utilizados. Para realizar este trabalho foi necessário unir três áreas: dinâmica veicular, instrumentação e metrologia. / [en] Experimental analysis is very important to know the characteristics of any product. The tests results can be used in researches or be compared with default values. In the second case it is necessary follow certain procedures that are described in standards and to compare the value of product s characteristics with the standard s requirements. Within the Basic Industrial Technology Domain, this activity is commonly designated as conformity assessment. But to measure these characteristics is necessary to use instruments. The instrumentation is the most important part in this process because if inadequate instruments are used, the result of the measurement will be incorrect and the errors may be great. Then it is necessary that the instruments had been correctly calibrated and have an adequate good accuracy, low uncertainty and ensure the repeatability and reproducibility of the measurements. Metrology is the science dealing with metrology reliability. In automotive tests happen the same, however it is necessary knowledge about vehicular dynamic too, to know how and what will be measured. The Brazilian Army Marambaia Proving Ground has an equipment used to vehicles evaluation that measure speed and distance using a non-contact optical sensor and a data acquisition system. This masters degree dissertation proposes an alternative for this equipment s Central Processing Unit substituting it for a laptop with a data acquisition board and a specific software with data processing tools to process the same non-contact optical sensor s signals. However this is not enough, it s necessary a metrological approach of the data acquisition system to ensure the uncertainty of measurement and avoid false accept risk and false reject risk. In the context of the developed metrological approach, both the measurement systems were evaluated, the system originally in use and the alternative system proposed that will substitute the first. The knowledge about the associated uncertainties constitute a strategic resource to the important stage of the used equipment s calibration. To carry through this work it was necessary to join three areas: vehicular dynamic, instrumentation and metrology.
54

[en] EXPERIMENTAL PROCEDURE FOR A METROLOGICAL EVALUATION OF THE PERFORMANCE OF A MICROTURBINE USED FOR ELECTRIC ENERGY GENERATION / [pt] PROCEDIMENTO EXPERIMENTAL PARA AVALIAÇÃO METROLÓGICA DO DESEMPENHO DE UMA MICROTURBINA UTILIZADA PARA GERAÇÃO DE ENERGIA ELÉTRICA

ALEX SANDER ASSUNCAO 15 September 2004 (has links)
[pt] O uso de tecnologias para incrementar a geração distribuída de energia elétrica, particularmente microturbinas a gás, tem aumentado ultimamente devido à crise de energia que muitos países, como o Brasil têm passado o que é um incentivo à produção independente de energia elétrica. Procedimentos têm sido desenvolvidos para verificar os dados de desempenho de microturbinas, com objetivo de comissionamento. Quando alguém compra um sistema de geração de energia, sua partida pode apenas ser efetivada quando os dados do fabricante concordam com os de projeto, dentro de uma faixa de incerteza acordada, qualificando, portanto, estudos de viabilidade anteriormente realizados. Muitos procedimentos são detalhados para verificar os dados de desempenho sob condições de teste, extrapolando-os para outras diferentes. Potência, consumo de gás, emissão dos gases, qualidade da energia elétrica (incluindo distorção harmônica e frequência) estão entre os parâmetros normalmente medidos. A freqüência de aquisição de dados é normalmente especificada para atender as características de desempenho do equipamento sob condições estáveis de teste. Também, a incerteza dos instrumentos de medição é normalmente especificada, sem qualquer referência à incerteza expandida dos parâmetros calculados, que são usados para caracterizar seu desempenho. Este trabalho descreve um método para avaliação dos dados de desempenho de uma microturbina a gás, juntamente com uma metodologia para calcular a incerteza dos parâmetros que caracterizam seu desempenho, com objetivos de comissionamento, a partir da incerteza dos instrumentos de medição, e fazendo uma análise crítica dos objetivos de medição a serem alcançados. A metodologia é baseada nos conceitos metrológicos mais recentes, de forma que resultados confiáveis possam ser alcançados, utiliza condições de referência, estabelecidas por norma internacional [ISO-2314, 1973], para especificação dos dados de desempenho dos equipamentos, com objetivo de comparação, e segue as diretrizes da U.S. Enveronmental Protection Agency para especificação do desempenho a ser alcançado. / [en] The use of technologies for increasing distributed electric energy generation, particularly gas fired microturbines, has been lately growing due to the energies crisis many countries, including Brasil, have experienced, which is an incentive to an independent electric energy production. Procedures have been developed to check microturbine performance data for commissioning purposes. When somebody buys an energy production plant, its start-up can only be accomplished when manufacturers data matches the design data within an agreed uncertainty band, thus qualifying the previously made feasibility studies. Many procedures are detailed for checking the performance data under testing conditions, and extrapolating them for different ones. Power, gas consumption, gas emissions, electric energy quality (including harmonic distortion and frequency) are among the usually measured parameters. Data acquisition frequency is usually specified to match specified equipment behaviour under stable test conditions. Also, the uncertainty of the measurement instruments are usually specified, without, however, defining the expanded uncertainty of the calculated parameters, which are used to characterize their performance. This work presents a method for evaluating the gas fired microturbine performance data for electric energy generation, together with a methodology for calculating the uncertainty of parameters that characterize its performance for commissioning purposes, starting up from the uncertainty of the measurement instruments, and making a critical analysis of the measurement goals. The methodology is based on most recently used metrology concepts, so that reliable results can be achieved, uses ISO reference conditions for specifying equipment performance data for comparison purposes and follows U.S. Environment Protection Agency directions for specifying performance goals.
55

[en] PROPOSITION OF METROLOGICAL CONTROL FOR MEASUREMENT OF CRYOGENIC LIQUIDS / [pt] PROPOSIÇÃO DE CONTROLE METROLÓGICO NA MEDIÇÃO DE LÍQUIDOS CRIOGÊNICOS

IRIS DA SILVA TRINDADE 16 January 2004 (has links)
[pt] Líquidos criogênicos são amplamente empregados em diversos segmentos da atuação humana, destacando-se a Medicina, Engenharia Genética, setor industrial e no desenvolvimento cientifico. Sendo assim, efetuar o controle metrológico sobre os dispositivos e sistemas utilizados na comercialização de tais materiais é fundamental. Nesta dissertação propomos a implementação do controle metrológico neste segmento como forma de estabelecer confiabilidade e garantir trocas cada vez mais justas, sem prejuízos as partes envolvidas. Para tal, a estrutura legal é amparada pela regulamentação vigente no âmbito brasileiro, a qual é abordada e confrontada com as diretrizes internacionais. Os diferentes sistemas de medição atualmente adotados são abordados, com o intuito de julgar a adequação dos mesmos e estabelecer requisitos mínimos. Diante da inexistência de uma regulamentação ampla, capaz de agregar aspectos não só inerentes às boas práticas, mas que contemplem a realidade do mercado nacional, são estabelecidas proposições e diretrizes a serem seguidas na implementação e efetivação do controle metrológico. / [en] Cryogenic liquids are widely employed in several fields of human activity,such as in Medicine, Genetics Engineering, the industrial sector and for the scientific development. This way, applying the metrological controls in devices and systems used for the commercialization of cryogenic liquids is essential. In this dissertation we proposed the implementation of the metrological controls in this area, objectifying to establish the reliability and the guarantee of fair trade,without damages for the involved parts. Thus, the legal structure is supported by the valid regulamentation in the Brazilian case, that is mentioned and faced against international policies. The different measurement systems adopted nowadays are approached, for judging their adequacy and establishing minimum requests. Considering that there is not a broad regulamentaion, capable of aggregate aspects of the good practice and to heed the national reality, proposals and guidelines are presented for reaching the implementation of effective metrological controls.
56

[en] INTERFEROMETRIC LINEAR LASER MEASURING SYSTEM CALIBRATION BY COMPARATIVE METHOD / [pt] IMPLEMENTAÇÃO E VALIDAÇÃO DE MÉTODO COMPARATIVO DE CALIBRAÇÃO DE SISTEMA DE MEDIÇÃO LINEAR POR INTERFEROMETRIA LASER

WELLINGTON SANTOS BARROS 24 June 2003 (has links)
[pt] O presente trabalho tem por objetivo implantar um método para calibração de sistema de medição linear por interferometria laser por meio de comparação a um outro sistema laser de referência. O referido método é considerado mais simples que a calibração por componentes realizada atualmente e, conforme demonstrado no trabalho, apresenta confiabilidade metrológica que atende a exatidão necessária para as aplicações dos laseres em metrologia dimensional, vindo suprir uma necessidade metrológica dos laboratórios credenciados pelo Instituto Nacional de Metrologia, Normalização e Qualidade Industrial (Inmetro) e do parque industrial brasileiro, usuários destes sistemas de medição. A implantação do sistema para calibração de lasers de medição foi baseada em normas internacionais de calibração e de cálculo da incerteza de medição e utilizou um sistema laser de referência calibrado no Inmetro, com rastreabilidade a padrões nacionais, com as menores incertezas possíveis. O método de medição implantado realiza a calibração de um sistema laser por comparação a outro utilizando medições feitas a partir do deslocamento da mesa onde é a apoiado o prisma óptico. O que é de fato analisado é a diferença das medições dos dois sistemas laser para um mesmo deslocamento. Foram registradas as diferenças das indicações de 200 mm em 200 mm de deslocamento, em um total de 2000 mm, que variaram de 0,027 µm a 0,690 µm. Foram realizadas três medições para cada deslocamento e quatro repetições completas do procedimento em dias diferentes, com variação do desvio padrão de 0,009 µm a 0,098 µm e incertezas expandidas que variaram de 0,109 µm a 0,306 µm. São apresentadas a metodologia de calibração, cálculos das correções, fontes de erros e cálculos da incerteza de medição para a comparação de sistemas laseres de medição linear. / [en] The present work aims at the implementation of a calibration method for interferometric linear laser measurement systems by comparison to another reference system. The proposed method is considered simpler than the calibration by components that is carried out today at Inmetro (National Institute of Metrology, Standardization and Industrial Quality) and, as demonstrated along this work, presents the metrological reliability and accuracy necessary for several applications of lasers in dimensional metrology. This approach will supply the metrological needs of several laboratories accredited by Inmetro and of the Brazilian industry in general, users of such measurement systems, regarding cost and time of calibration. The method implemented was based on international technical standards related to calibration and uncertainty calculation and used a reference system calibrated at Inmetro, with traceability to national standards, with the lowest uncertainties that could be achieved. The said method performs the calibration of a laser system by comparison to another through measurements of the displacement of the table where the optical prism rests. What is indeed analyzed is the difference of the measurements obtained by the two laser systems for the same table displacement. The differences were recorded for each displacement of 200 mm, in a total of 2,000 mm, their variation being from 0.027 µm to 0.690 µm. The whole procedure was repeated four times, in different days, with three measurements for each displacement. Their standard deviation varied from 0.009 µm to 0.098 µm while their expanded uncertainties varied from 0.109 µm to 0.306 µm depending on the value of the displacement. The calibration methodology, correction calculation, errors sources and measurement uncertainty calculations for the linear measurement laser systems comparison are presented in this dissertation.
57

[en] METROLOGICAL CONTROL OF LIGHTING IN STANDARDS BOOTHS FOR VISUAL APPRAISAL / [pt] CONTROLE METROLÓGICO DA ILUMINAÇÃO EM CABINES PADRONIZADAS DE AVALIAÇÃO VISUAL

MIGUEL DE FREITAS CHRISTINO 19 October 2004 (has links)
[pt] Não obstante os sofisticados avanços em tecnologias ópticas, ainda não existem fontes de luz artificial capazes de simular de forma adequada a luz do dia natural. Alcançar um padrão de iluminação como este representará uma redução nos custos de produção, em função de retrabalhos gerados por avaliações visuais pouco confiáveis, e nas divergências comerciais relacionadas a produtos que têm como característica de controle a cor, tais como artigos têxteis, gráficos, de merchandising etc. A presente pesquisa de mestrado em metrologia relaciona-se à avaliação metrológica das fontes luminosas e cabines de iluminação disponíveis no mercado e à sua adequação às normas que definem especificações técnicas, com o propósito de estimular introdução de inovação tecnológica em novos desenvolvimentos industriais capazes de melhorar o desempenho desses aparatos. A pesquisa contribui, também, com o desenvolvimento de um diagnóstico do acervo de normas técnicas disponíveis aplicáveis à padronização de sistemas de iluminação; investigação de lâmpadas fluorescentes usualmente utilizadas como simuladores de luz do dia e avaliação metrológica de cabines de iluminação disponíveis no mercado. Em particular, medições foram realizadas em um sistema espectroradiométrico de alta definição, que utiliza um monocromador duplo com capacidade de dispersão do feixe de 2 nm/mm. Ensaios e análises de repetitividade e reprodutibilidade conduzidas no sistema de medição espectroradiométrico permitiu quantificar a variabilidade associada a cada lote de fabricação dos simuladores de luz do dia, comercializados na forma de lâmpadas fluorescentes disponíveis no mercado nacional. Caracterizada a variação da distribuição espectral ao longo do eixo das fontes luminosas investigadas (lâmpadas) foi possível desenvolver uma análise do impacto induzido na uniformidade da iluminação obtida em cabines industrializadas, assim definindo um fator de diferenciação de interesse técnico e comercial. A pesquisa revelou que nenhum dos simuladores de luz do dia testados atingiu os requisitos mínimos estabelecidos para a comparação visual de cores, quando avaliados com base em normas e práticas internacionais. Foram ainda realizadas medições para se verificar a influência dos elementos construtivos das cabines na distribuição espectral de potência na área de avaliação. Fundamentado nas 1578 medições realizadas em condições laboratoriais que simulam ambientes industriais, a pesquisa comprova que alterações nas características construtivas das cabines possuem impacto no resultado da classificação das distribuições espectrais de potência, criando assim uma condição facilitadora para que as especificações normativas sejam atingidas, mesmo com a utilização de lâmpadas fluorescentes disponíveis no mercado e de preço reduzido. / [en] Notwithstanding the complex advances in optical technologies, there are still no artificial light sources capable of adequately simulating the natural daylight. Reaching such a lighting standard will represent a reduction of the production costs, in view of the rework caused by not so reliable visual evaluations, and of the commercial conflicts related to products that have colour as one of their control characteristics, such as textile, graphics and merchandising articles. The present Master degree metrology research is related to the metrological evaluation of the lighting sources and light booths available in the market (commercially available), and to their conformity to the technical specifications standards, aiming to stimulate the introduction of technological innovation to new industrial developments eligible to enhance the performance of these apparatus. The research has also contributed to the development of a diagnosis of the collection of the existing technical standards applied to the standardisation of lighting systems; to the investigation of fluorescent lamps generally used as daylight simulators, and to the metrological evaluation of light booths available in the market (commercially available). Particularly, analyses were done with a highly precise spectroradiometric system that uses a double monochromator with capacity for beam dispersion of 2 nm/mm. Tests and analyses on repeatability and reproducibility made with the spectroradiometric measurement system let to quantify the variety associated with each manufactured set of daylight simulators, commercialised as fluorescent lamps available at the local market. Having the spectral distribution determined throughout the axis of the studied lighting sources (lamps) it was possible to develop an analysis of the impact caused at the lighting uniformity obtained for industrial light booths, and so, specifying a distinctive factor technically and commercially interesting. The research revealed that, when evaluated considering the international practices and standards, none of the daylight simulators tested achieved the minimum requirement indicated for the visual comparison of colours. In addition, measurements were done to verify the influence of the light booths building pieces at the power spectral distribution within the evaluation area. Based on 1578 measurements done at laboratorial conditions simulating industrial environment, the research proves that changes in the building characteristics of the light booths produce an impact at the result of the power spectral distribution classification, creating, thus, a smooth condition for the attendance of the standards specifications, even when using low-cost fluorescents lamps available in the market.
58

[en] DEVELOPMENT OF A HIGH SENSITIVITY PRESSURE TRANSDUCER, BASED ON THE PHENOMENON OF GIANT MAGNETOIMPEDANCE EFFECT, FOR BIOMEDICAL APPLICATION / [pt] DESENVOLVIMENTO DE UM TRANSDUTOR DE PRESSÃO DE ALTA SENSIBILIDADE, BASEADO NO FENÔMENO DE MAGNETOIMPEDÂNCIA GIGANTE, PARA APLICAÇÃO BIOMÉDICA

DANIEL RAMOS LOUZADA 06 November 2006 (has links)
[pt] A presente dissertação apresenta o desenvolvimento de um transdutor de pressão de alta sensibilidade, desenvolvido para aplicações biomédicas. O transdutor é baseado em um sensor de magnetoimpedância gigante (MIG), anteriormente desenvolvido, pelo Laboratório de Biometrologia da PUC-Rio. O conhecimento a cerca das principais características do fenômeno MIG serviu de guia para as ações que foram tomadas, a fim de se estabelecer uma configuração que apresentasse maior sensibilidade ao transdutor. Mesmo que algumas dificuldades encontradas, principalmente devidas a características acústicas não levadas em consideração, apontem para a necessidade de aperfeiçoamentos, com a configuração desenvolvida no presente trabalho já é possível obter o registro do pulso arterial carotídeo. Comparações entre o transdutor ora desenvolvido e com outros transdutores de pressão existentes no mercado também destinados a aplicações biomédicas, apontam para uma sensibilidade do transdutor ora desenvolvido de magnitude igual ou mesmo superior aos convencionais. / [en] This dissertation presents a high sensitivity pressure transducer, developed for biomedical applications. The transducer is based on a Giant Magnetoimpedance (GMI) sensor previously developed at the Laboratory of Biometrology of PUC-Rio. Knowing the main characteristics of the phenomenon and of the GMI strips used, the configuration which should yield the highest possible sensitivity has been implemented. Even though some enhancements in the acoustic characteristics of the transducer are still necessary, it was already possible to record the carotid arterial pulse. Comparing the transducer herein presented with other pressure transducers also destined to biomedical applications, it already has a sensitivity of the same order of magnitude or even higher.
59

[en] INCLUSION OF STATISTICAL METHODS AS BILLING SUPPORT OF SMART METERS / [pt] INCLUSÃO DE MÉTODOS ESTATÍSTICOS COMO APOIO AO FATURAMENTO DE ENERGIA REALIZADO POR MEDIDORES INTELIGENTES

WEULES FERNANDES CORREIA 03 October 2018 (has links)
[pt] A sociedade está vivendo em uma época de forte convergência tecnológica, onde novas tecnologias são descobertas e extintas em um prazo cada vez menor. Esta revolução tecnológica também já chegou para o setor de infraestrutura de distribuição de energia que são as Redes Elétricas Inteligentes, sendo o medidor inteligente o principal equipamento desta revolução. Apesar da evolução do parque de medidores brasileiros, a regulação comercial não acompanhou esta modernização e continua tendo como referência o sistema de medição convencional com a atuação de leituristas e não considerando as oportunidades de usar dados de consumo, mesmo que não sejam da data do faturamento nos casos de falhas de transmissão da informação e aplicação de ferramentas estatísticas para estimação no faturamento. Neste contexto, esta dissertação tem como objetivo avaliar as regras regulatórias de faturamento considerando as ausências de leituras, propor uma nova metodologia para definir como realizar o faturamento na ausência de leituras considerando consumos anteriores e usar ferramentas estatísticas para a definição do valor a ser faturado. A metodologia pode ser dividida em duas fases: (i) imputação de dados faltantes na base de dados decorrentes de possíveis erros de transmissão dos medidores; (ii) previsão do consumo de energia elétrica por cliente. O presente trabalho cumpriu os objetivos aos quais se propôs e apresentou uma alternativa promissora para o faturamento com medidores inteligentes e que utilize tecnologias de comunicação de baixo custo e que possam apresentar uma efetividade de medição abaixo da ideal, no caso, 100 por cento. / [en] Society is living in a time of strong technological convergence, where new technologies are discovered and extinguished in an ever shorter time frame. This technological revolution has also arrived for the energy distribution infrastructure with the Smart Grid, in which the smart meter being the main equipment of this revolution. Despite the evolution of the Brazilian meter park, the commercial regulation did not go along with this modernization and continues with reference to the conventional metering system and not considering the opportunities to use consumption data comes from out of the billing date, in cases of data transmission failures, being thus possible use statistical tools for billing estimation. In this context, this dissertation aims to evaluate the regulatory rules of billing considering the absences of readings, proposing a new methodology to define how to estimate the billing in the absence of readings, considering previous consumption and using statistical tools to define the value to be billed. The methodology can be divided into two phases: (i) imputation of missing data in the database, resulting from possible transmission errors of the meters; (ii) forecast of electricity consumption per customer. The present work fulfilled the objectives proposed and presented a promising alternative for billing with smart meters using low cost communication technologies that could have low measurement effectiveness, in this case, 100 percent.
60

[en] MULTIPARAMETER QUALITY BY DESIGN FUZZY IN THE DEVELOPMENT OF A MEASURING SYSTEM FOR CLINICAL USE / [pt] QUALITY BY DESIGN FUZZY MULTI-PARAMÉTRICO NO DESENVOLVIMENTO DE SISTEMA DE MEDIÇÃO PARA USO CLÍNICO

DANIEL RENE TASE VELAZQUEZ 21 February 2018 (has links)
[pt] Este trabalho apresenta a adaptação da abordagem Quality by Design (QbD) visando aplicá-la na garantia da qualidade de um sistema de medição para uso clínico destinado à localização de objetos estranhos metálicos não-ferromagnéticos inseridos no corpo humano. O Target Product Profile (TPP) foi identificado em associação às funcionalidades do sistema, atendendo a preceitos biometrológicos como: desempenho metrológico, baixo custo de fabricação e operação, baixa complexidade, portabilidade e segurança/inocuidade. Determinaram-se os Critical Quality Attributes (CQAs) do sistema, que devem ser controlados ao longo do seu desenvolvimento para garantir sua qualidade. Identificaram-se os Critical Process Parameters (CPPs) e suas faixas de variação aceitáveis. Foi realizada uma análise de risco prévia entre CQAs e CPPs, determinando aqueles com maior relação de dependência, a fim de estabelecer as combinações adequadas para construir o Design Space (DS). Devido às caraterísticas dos dados obtidos nas primeiras etapas da implementação do QbD, empregou-se a inferência fuzzy entre os CPPs e CQAs com elevada dependência. Os resultados obtidos com a configuração do DS possibilitaram a determinação das faixas de operação aceitáveis dos CPPs, as quais garantem a adequação dos aspectos metrológicos do equipamento biomédico em desenvolvimento, contribuindo, para a confiabilidade da sua aplicação diagnóstica e terapêutica. / [en] This work presents the adaptation of the Quality by Design (QbD) approach aiming to apply it to the quality assurance of a measurement system for clinical use for locating non-ferromagnetic metallic foreign objects inserted in the human body. The Target Product Profile (TPP) was identified in association with the functionalities of the system, complying with biometrological precepts such as: metrological performance, low manufacturing and operating costs, low complexity, portability and safety. The Critical Quality Attributes (CQAs) of the system were determined, which must be controlled throughout its development to guarantee its quality. Critical Process Parameters (CPPs) and their acceptable ranges of variation were identified. A risk analysis was previous performed between CQAs and CPPs, determining those with a higher dependency ratio, in order to establish the appropriate combinations to construct the Design Space (DS). Due to the characteristics of the data obtained in the first stages of the implementation of QbD, fuzzy inference was used between CPPs and CQAs with high dependence. The results obtained with the DS configuration enabled the determination of the acceptable operating ranges of the CPPs, which ensure the adequacy of the metrological aspects of the biomedical equipment under development, contributing to the reliability of its diagnostic and therapeutic application.

Page generated in 0.0376 seconds