• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 365
  • 155
  • 24
  • 2
  • Tagged with
  • 541
  • 280
  • 155
  • 130
  • 120
  • 113
  • 98
  • 70
  • 70
  • 62
  • 52
  • 51
  • 45
  • 43
  • 42
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Incertitude des mesures de débit des cours d’eau au courantomètre. Amélioration des méthodes analytiques et apports des essais interlaboratoires / Uncertainty in discharge measurements using the velocity-area method. Improvement of analytical methods and contribution of field inter-laboratory experiments

Despax, Aurélien 27 September 2016 (has links)
Lors des crises (sécheresses ou crues) les données hydrométriques participent directement aux processus de décision pour la gestion en temps réel de la ressource en eau mais également à l'analyse a posteriori pour le règlement des litiges. Pour pouvoir prendre des décisions cohérentes, il est alors essentiel de connaître l'incertitude associée aux données de débit. Si les techniques hydrométriques se sont nettement améliorées au cours des dernières décennies, l'estimation des incertitudes reste un défi pour la communauté de l'hydrométrie.Cette étude, portant sur la quantification des incertitudes des jaugeages au courantomètre, s'inscrit dans une suite de travaux récents dont la perspective vise la mise à jour potentielle de la norme ISO 748. Une méthode de propagation analytique des incertitudes, nommée FLAURE, est exposée dans ce manuscrit. Elle permet de pallier les inconvénients des méthodes existantes et vise l’objectivation des différentes sources d’incertitude. Une attention particulière est portée au terme prépondérant d’incertitude dû à l’intégration latérale des profils de vitesse et de bathymétrie (u’m). Pour cela un lien a été établi entre un indice de qualité d’échantillonnage et les erreurs d’interpolation latérale des profils grâce à l’étude de jaugeages à haute résolution latérale de mesure.En l’absence d’étalon de référence en termes de débit d’un cours d’eau, l’apport des essais interlaboratoires, permettant d’obtenir une estimation de l’incertitude dans les conditions des essais, est discuté. La confrontation des approches analytiques à deux campagnes d’essais interlaboratoires a montré les limites de ces deux approches et n’a pas permis de mettre en évidence une méthode analytique fiable. Néanmoins, la multiplication des campagnes d’essais de ce type dans des conditions variées permettra, à terme, d’aboutir à un calcul d’incertitude plus fiable grâce notamment à l’estimation de composants d’incertitude jusqu’alors omis. / During crisis (droughts or floods) hydrometric data are essential for decisions, in real-time, related to water resource management but also afterwards in cases of disagreement. Discharge measurements are the first step to produce such data and associated uncertainty has to be estimated in order to make coherent decisions. Although discharge measurements techniques have improved in recent years, uncertainty analysis is still a challenge in hydrometry.This study aims to estimate uncertainty in discharge measurements using the velocity-area method with potential perspective of ISO 748 standard updating. Different analytical methods, that follow the guide to the expression of uncertainty in measurement, are available in the literature, all with their own limitations and drawbacks. To address the limitations of existing methods, this study presents a new methodology, called FLAURE, to estimate the uncertainty components. Special attention is given to the estimation of u’m component related to cross-sectional interpolation errors. High-resolution reference gaugings are used to assess the uncertainty component through a statistical analysis. The method then establishes an explicit link between the estimation of cross-sectional interpolation errors and a sampling quality index.It is a challenging task to assess which analytical method provides the best uncertainty estimation due to the lack of streamflow measurement reference standards in natural streams. A useful tool to empirically estimate the uncertainty of a gauging method is the field inter-laboratory experiments. This study presents a comparison between analytical methods and two field inter-laboratory experiments. The comparison has shown the limits of these two approaches and has not highlighted the best analytical method. However, further comparisons, with various site conditions, between the two approaches will probably consolidate analytical methods and improve the reliability of discharge uncertainty estimates.
52

Impact pronostique du débit cardiaque dans la sténose valvulaire aortique / Prognostic impact of cardiac output in aortic valve stenosis

Le Ven, Florent 13 December 2016 (has links)
La sténose aortique (SA) est la maladie valvulaire cardiaque ayant la plus forte prévalence dans les pays occidentaux. On s’aperçoit que, malgré le respect des recommandations pour les indications opératoires, les patients présentent des évolutions très variables après chirurgie : certains patients restent symptomatiques, décèdent précocement, ou présentent une dysfonction ventriculaire gauche persistante. Il a été montré que les patients présentant à la fois une SA en bas débit (c’est-à-dire un volume d’éjection bas), une fraction d’éjection ventriculaire gauche (FEVG) altérée et un gradient de pression entre le ventricule et l’aorte abaissé avaient un pronostic péjoratif, avec un risque opératoire majoré lorsqu’ils subissaient un remplacement valvulaire chirurgical. Il a aussi été récemment démontré que, dans le contexte de la SA, un bas débit peut survenir alors que la FEVG est normale. Les objectifs généraux de ce doctorat sont d’étudier l’impact du débit (plus précisément le volume d’éjection ventriculaire gauche) sur le pronostic des patients atteints de SA, ainsi que l’évolution du débit après intervention et les déterminants de son évolution. Les résultats indiquent que le volume d’éjection ventriculaire gauche, que ce soit avant intervention, ou son évolution après TAVI (Transcatheter Aortic Valve Implantation), sont des prédicteurs indépendants puissants de mortalité chez ces patients. / Aortic stenosis (AS) is the most common valvular heart disease in occidental countries. Despite proper use of the guidelines, some patients can present adverse outcomes after surgery: some of them remain symptomatic, some die prematurely, or suffer from a persistant left ventricular dysfunction. It has been demonstrated that patients presenting an AS with low flow (i.e. low stroke volume), impaired left ventricular ejection fraction (LVEF), and a low transvalvular mean gradient, have poor prognosis, with increased risk during aortic valve replacement surgery. It has also been demonstrated that, in AS, a low flow can occur despite a preserved LVEF. The main goals of this PhD were to evaluate the impact of flow (more precisely left ventricular stroke volume) on the prognosis of patients with AS, the evolution of flow after intervention, and the factors that influence it. The results show that left ventricular stroke volume, before or after intervention, or its evolution after TAVI (Transcatheter Aortic Valve Implantation), are powerful independant predictors of mortality.
53

Science des données au service des réseaux d'opérateur : proposition de cas d’utilisation, d’outils et de moyens de déploiement / Data science at the service of operator networks

Samba, Alassane 29 October 2018 (has links)
L'évolution des télécommunications amené aujourd'hui à un foisonnement des appareils connectés et une massification des services multimédias. Face à cette demande accrue de service, les opérateurs ont besoin d'adapter le fonctionnement de leurs réseaux, afin de continuer à garantir un certain niveau de qualité d'expérience à leurs utilisateurs. Pour ce faire, les réseaux d'opérateur tendent vers un fonctionnement plus cognitif voire autonomique. Il s'agit de doter les réseaux de moyens d'exploiter toutes les informations ou données à leur disposition, les aidant à prendre eux-mêmes les meilleures décisions sur leurs services et leur fonctionnement, voire s'autogérer. Il s'agit donc d'introduire de l'intelligence artificielle dans les réseaux. Cela nécessite la mise en place de moyens d'exploiter les données, d'effectuer surelles de l'apprentissage automatique de modèles généralisables, apportant l’information qui permet d'optimiser les décisions. L'ensemble de ces moyens constituent aujourd'hui une discipline scientifique appelée science des données. Cette thèse s'insère dans une volonté globale de montrer l'intérêt de l'introduction de la science des données dans différents processus d'exploitation des réseaux. Elle comporte deux contributions algorithmiques correspondant à des cas d'utilisation de la science des données pour les réseaux d'opérateur, et deux contributions logicielles, visant à faciliter, d'une part l'analyse, et d'autre part le déploiement des algorithmes issus de la science des données. Les résultats concluants de ces différents travaux ont démontré l'intérêt et la faisabilité de l'utilisation de la science des données pour l'exploitation des réseaux d'opérateur. Ces résultats ont aussi fait l'objet de plusieurs utilisations par des projets connexes. / The evolution of telecommunications has led today to a proliferation of connected devices and a massification of multimedia services. Faced with this increased demand for service, operators need to adapt the operation of their networks, in order to continue to guarantee a certain level of quality of experience to their users. To do this, operator networks tend towards a more cognitive or autonomic functioning. It is about giving the networks the means to exploit all the information or data at their disposal, helping them to make the best decisions about their services and operations,and even self-manage. It is therefore a questionof introducing artificial intelligence into networks. This requires setting up means to exploit the data, to carry out on them the automatic learning of generalizable models, providing information that can optimize decisions. All these means today constitute a scientific discipline called data science. This thesis fits into a global desire to show the interest of the introduction of data science in different network operating processes. It inlcudes two algorithmic contributions corresponding to use cases of data science for the operator networks, and two software contributions, aiming to facilitate,on the one hand, the analysis, and on the other hand the deployment of the algorithms produced through data science. The conclusive results of these various studies have demonstrated the interest and the feasibility of using data science for the exploitation of operator networks. These results have also been used by related projects.
54

Modèles prédictifs utilisant des données moléculaires de haute dimension pour une médecine de précision en oncologie / Predictive models using high dimensional molecular data for precision medicine in oncology

Ferte, Charles 17 December 2013 (has links)
Le niveau médiocre des taux de réponses et des améliorations de survie lorsque des stratégies conventionnelles sont appliquées souligne la nécessité de développer des outils prédictifs performants, robustes et applicables en clinique. La démocratisation des technologies d’analyses à haut-débit est le substrat de la médecine de précision permettant le développement de modèles prédictifs capables d’orienter les stratégies thérapeutiques et la définition d’une nouvelle taxonomie des cancers par l’intégration de données moléculaires de haute dimension. A travers cette thèse, nous avons d’abord analysé des données publiques d’expression génique de cancer bronchique non à petites cellules dans le but de prédire la probabilité de survie à trois ans. Le fort pouvoir prédictif de la TNM seule et la faible taille des cohortes de validation ont malheureusement limité la possibilité de traduire nos résultats en clinique. Nous avons ensuite développé un prédicteur du phénotype « KRAS muté » spécifique du cancer colorectal, permettant d’identifier de nouveaux traits moléculaires responsables de ce phénotype et d’améliorer la prédiction de la réponse au cetuximab chez les patients KRAS sauvage. Enfin, nous avons combiné les données moléculaires des panels de lignées cellulaires CCLE et Sanger avec les données des cohortes du TCGA pour produire des prédicteurs performants de la sensibilité aux drogues. Ces modèles sont concordants avec des screens produits par interférence RNA et permettent d’expliquer la réponse extrême de patients sectionnés dans le programme de screening moléculaire MOSCATO.Les défis spécifiques posés par les données moléculaires de haute dimension dans le développement d’outils prédictifs applicables en clinique sont discutés dans cette thèse. / The mediocre level of the rates of answers and the improvements of survival when conventional strategies are applied underlines the necessity of developing successful, strong and applicable predictive tools in private hospital. The democratization of the technologies of analyses with top-debit(-flow) is the substratum of the medicine of precision allowing the development of predictive models capable of directing the therapeutic strategies and the definition of a new taxonomy of cancers by the integration of molecular data of high dimension(size).Through this thesis(theory), we analyzed at first public data of genic expression of bronchial cancer not in small cells(units) with the aim of predicting the probability of survival in three years. The strong predictive power of the only TNM and
55

Channel modeling for the investigation of human absorption in realistic indoor environments / Modélisation de canal pour l'étude de l'absorption humaine dans les environnements intérieurs réalistes / Kanaalmodellering voor het onderzoek van de menselijke absorptie in realistische indooromgevingen

Bamba, Aliou 30 June 2015 (has links)
Nous montrons après une revue des modèles de canaux sans fil que le «room electromagnetics» est un modèle approprié pour aborder l'absorption humaine due aux ondes électromagnétique diffuses. Une méthode pour déterminer le temps de réverbération dans une chambre réverbérante est présentée et validée avec un algorithme à haute résolution. La section transversale d'absorption due aux champs diffus (ACSwb,dmc) est ensuite présentée. Une méthode expérimentale pour déterminer le ACSwb,dmc d'un fantôme est développée et validée par des simulations numériques. Les propriétés du temps de réverbération sont étudiées dans plusieurs environnements à Gand et Aalborg, en utilisant le sondeur de canal virtuel MIMO et le sondeur de canal réel. Les valeurs du temps de réverbération permettant ensuite la détermination du ACSwb,dmc. En outre, nous présentons pour la première fois une méthode expérimentale pour déterminer le débit d'absorption spécifique (SARwb) dans des conditions de propagation réalistes en environnements intérieurs. Plusieurs scénarii ont été envisagés et il s’avère que la contribution des champs diffus dans le débit d'absorption spécifique peut être importante et ne peut être systématiquement négligé.Par ailleurs, une simple formule (comme une alternative aux méthodes numériques et expérimentales) est proposée pour déterminer le SARwb d’humains en présence de champs diffus. La formule est validée par des simulations numériques de fantômes humains hétérogènes et peut être utilisée en dosimétrie pour évaluer rapidement et avec précision le SARwb,total des humains.Enfin, la conclusion et des futures possibilités de recherche concluent cette thèse. / We briefly review the modeling of wireless channels. We demonstrate that the room electromagnetics is a suitable channel model to address the human absorption due to diffuse fields. Next, an easy-to-implement methodology to determine the reverberation time in a reverberation chamber is presented and validated with a high-resolution algorithm. Then, we introduce the absorption cross section in diffuse fields (ACSwb,dmc). An experimental method to determine the ACSwb,dmc of a canonical phantom is developed and validated via numerical simulations. The reverberation time properties are investigated in several offices in Ghent (Belgium), and in Aalborg (Denmark), using the virtual Multiple-Input Multiple-Ouput channel sounder and the real channel sounder. Next, the reverberation time values allow us the measurement of the ACSwb,dmc of humans in a realistic office. We then address for the first time an experimental method to determine the whole-body averaged specific energy absorption rate (SARwb) of humans under realistic propagation conditions in indoor environments. Several scenarios have been considered and we show that the contribution of the diffuse fields in the absorption rate of humans may be prominent and cannot be systematically neglected. Moreover, a simple formula (as an alternative to numerical and experimental approaches) is proposed to determine the total SARwb of humans in presence of diffuse fields. The formula is validated via numerical simulations of four 3-D heterogeneous human models and can be used in dosimetry studies to assess accurately and rapidly the total SARwb of humans.Finally, a conclusion and future research opportunities end this thesis.
56

Caractérisation d'aptamères par électrophorèse capillaire couplée au séquençage haut-débit Illumina / Characterization of aptamers by capillary electrophoresis coupled to the hight throughput sequencing Illumina

Ric, Audrey Marie Amélie 29 September 2017 (has links)
Les aptamères sont des oligomères d'ADN ou d'ARN simple brin qui, en se repliant sous forme de structures tridimensionnelles peuvent avoir des interactions fortes et spécifiques envers un certain nombre de cibles. L'objectif de cette thèse a été de compléter les études existantes sur l'utilisation de l'électrophorèse capillaire (CE) et les aptamères afin de mettre au point une méthode de sélection d'aptamères par CE couplée à la fluorescence induite par laser et le séquençage haut-débit Illumina. Dans un premier temps, nous avons mis au point une méthode de détection et de séparation par électrophorèse capillaire couplée à la double détection UV-LEDIF d'une banque d'ADN en interaction avec une cible : la thrombine. C'est un modèle déjà étudié pour lequel deux aptamères ont fait l'objet de publications. Nous avons utilisé l'aptamère T29 dans le cadre de notre étude car c'est celui qui présente la meilleure affinité. L'électrophorèse capillaire est un puissant outil analytique qui facilite l'efficacité de sélection des aptamères et précise la détermination des paramètres d'interactions. Nous avons ainsi pu déterminer la constante d'affinité KD par CE-UV-LEDIF sur le modèle de base : la thrombine. Par ailleurs, nous montrons également comment l'utilisation du tampon Tris peut dégrader un ADN simple brin en électrophorèse capillaire et nous proposons comme alternative l'utilisation d'un tampon sodium phosphate dibasique qui évite ce phénomène de dégradation. Enfin, nous expliquons la difficulté d'amplification par qPCR et PCR d'un aptamère comme le T29 ayant une structure en G-quadruplex. Nous avons montré que le séquençage haut-débit Illumina nous a permis de trouver une corrélation entre le nombre de molécules séquencées et le nombre de séquences obtenues. L'analyse des séquences obtenues montre une quantité importante (20%) de séquences de T29 qui ne correspondent pas à la séquence de cet aptamère. Cela prouve que les étapes de PCR et de séquençage haut débit pour la détection de G-quadruplex peuvent induire un biais dans l'identification de ces molécules. / Aptamers are oligomers of small single-stranded DNA or RNA which can have strong and specific interactions with some targets when they fold into three-dimensional structures. The objective of this thesis was to complete existing studies on the use of capillary electrophoresis in order to develop a method for the selection of aptamers by CE coupled to laser induced fluorescence and Illumina high-throughput sequencing. In a first step, we developed a method of detection and separation by capillary electrophoresis coupled with the double detection UV-LEDIF of a DNA library interacting with a target: thrombin. It is a model already studied and for which two aptamers have been published. We used aptamer T29 as part of our study because it has the best affinity. Capillary Electrophoresis is a powerful analytical tool that facilitates the selection efficiency of aptamers and specifies the determination of the interaction parameters. We thus were able to determine the affinity constant KD by CE-UV-LEDIF on the basic model: thrombin. Moreover, we also show how the use of Tris buffer can degrade single-stranded DNA during capillary electrophoresis and we propose as an alternative the use of a dibasic sodium phosphate buffer which avoids the phenomenon of degradation. Finally, we explain the difficulty of amplification by qPCR and PCR of an aptamer such as T29 with a G-quadruplex structure. We showed that the Illumina high-throughput sequencing allowed us to find a correlation between the number of sequenced molecules and the number of sequences obtained. Analysis of the sequences obtained shows a significant amount (20%) of T29 sequences which do not correspond to the sequence of this aptamer. This shows that the PCR and high-throughput sequencing steps for the detection of G-quadruplex can induce bias in the identification of these molecules.
57

Développement d'outils miniaturisés pour la microbiologie haut-débit / Miniaturized tools development for high-throughput microbiology

Lalanne aulet, David 17 October 2014 (has links)
La microbiologie est la science qui s'attache à l'étude des microorganismes et de leurs propriétés. Depuis ses débuts au XV II siècle, les méthodes développées par les microbiologistes ont permis de révéler un énorme potentiel de connaissances et d'applications. Dans les dernières décennies, les industriels ont vu un intérêt tout particulier dans ce domaine d'étude. Le besoin de prévenir les contaminations en inhibant le développement microbien, ou au contraire la volonté de l'optimiser pour profiter des capacités de transformations chimiques des microorganismes a fait naître une demande croissante de tests microbiologiques. Le faible rendement des méthodes traditionnelles ne permettant pas de satisfaire à cette demande, la recherche de nouvelles méthodes de test focalise les intérêts. Les outils fluidiques miniaturisés ont d'ores et déjà fait preuve de leur potentiel pour ce type d'application, bien que leur validation vis-à-vis des méthodes classiques manque souvent.Dans ce travail de thèse, nous avons développé des incubateurs miniaturisés et des méthodes de suivi de populations de microorganismes optimisés. L'objectif est d'aborder l'impact de la réduction d'échelle d'incubation sur la croissance par rapport aux dispositifs de culture traditionnel, pour ensuite aboutir à un outil haut-débit pour la caractérisation de biocides. / Microbiology is the part of science linked with the study of microorganisms and their properties. Since its beginnings in the XV IIth century, the methods developped by the microbiologists revealed a huge potential of knowledge and applications.In the last decades, industrials realized the interests of this study areaThe need to prevent contaminations by inhibiting microbial development, or on the contrary the will to improve it to enjoy the chemical transformations capacities of the microorganisms gave birth to an increasing demand for microbiological tests. The poor yield of traditionnal methods does not allow to satisfy this need, and the search for new test methods is thus focalizing interests. Miniaturized fluidic tools have already proven their potential for this kind of applications, and yet, their validation towards traditionnal methods often lacks.In this work, we aim at developping miniaturized cultivation techniques and optimized growth analysis methods, to study the scale reduction impact of incubator's size on growth, in order to end up with a high-throughput tool for biocide caracterization.
58

Nouvelles méthodes électrochimiques pour le criblage d’inhibiteurs de transcétolases / New electrochemical methods for the screening of transketolases inhibitors

Aymard, Chloé 09 November 2018 (has links)
Cette thèse a pour objectif de développer une méthode électrochimique permettant de cribler à haut débit des inhibiteurs d'enzymes. Pour cela, une enzyme cible a été sélectionnée pour son intérêt thérapeutique, la transcétolase (TK) : elle est impliquée dans de nombreuses pathologies (cancer, maladies neurodégénératives, diabète…) et dans la survie de certains parasites pathogènes. Afin de mesurer l'activité de la TK, deux systèmes rapporteurs ont été développés, à l'aide de plaques de criblage électrochimique (PCE) constituées de 96 électrodes indépendantes. Le premier système rapporteur repose sur un système bienzymatique nécessitant l'intervention d'une enzyme auxiliaire, la galactose oxydase (GAOx) sous forme libre ou immobilisée dans la laponite. Cette enzyme est capable d'oxyder les produits de réaction de la TK et de produire du peroxyde d'hydrogène. Le format 96 des PCE a permis d'optimiser rapidement la détection électrochimique par ampérométrie pulsée par intermittence (IPA) d'activité oxydase et seulement 10 minutes sont nécessaires pour réaliser 96 mesures simultanées. Parallèlement, afin d'exploiter au maximum le système à 96 électrodes, cette détection d'activité oxydase a également été réalisée, en 10 minutes par électrochimiluminescence. Cette méthode offre l'avantage d'être plus sensible et moins variable que par IPA, mais limite l'utilisation de matrice d'immobilisation d'enzymes. La GAOx a ensuite été utilisée pour mesurer l'activité TK, cependant, les conditions réactionnelles n'étant pas optimales en présence du système bienzymatique (TK-GAOx), des temps d'incubation longs sont nécessaires et sont peu adaptées au criblage d'inhibiteurs de la TK. Un second système rapporteur ne nécessitant plus d'enzyme auxiliaire et faisant intervenir uniquement un seul substrat de la TK a été optimisé. Ce système repose sur l'oxydation de l'intermédiaire réactionnel formé par la fixation du cofacteur (la thiamine pyrophosphate) et du substrat sur l'enzyme par le ferricyanure. Cette méthode permet de mesurer 96 activités TK en seulement 7 minutes et a aisément été utilisée pour cribler une bibliothèque de molécules. Le criblage de 1360 molécules a permis d'identifier un nouvel inhibiteur de cet enzyme, présentant une CI50 de 63 μM. Le système électrochimique a également été utilisé pour déterminer le mécanisme d'inhibition (non compétitive pure partielle) et la constante d'inhibition associée (3,4 μM). Ces résultats sont inédits dans le domaine de l'électrochimie et offrent un large éventail d'applications que ce soit pour le criblage d'activité enzymatiques ou d'inhibiteurs d'enzymes / This thesis focuses on the development of a new electrochemical method allowing the high throughputscreening of enzyme inhibitors. For this purpose, a target enzyme has been selected for its therapeutic interest,transketolase (TK): this enzyme is involved in many diseases (cancer, neurodegenerative diseases, diabetes ...) and inthe survival of pathogenic parasites. To measure TK activity, two reporter systems have been developed by usingelectrochemical plates, composed of 96 independent electrodes.The first one is based on a bienzymatic system, requiring the use of an auxiliary enzyme, galactose oxidase(GAOx), in its soluble form or immobilized in laponite. This enzyme is able to oxidize TK products and producehydrogen peroxide. The 96-well format allowed to quickly optimize the electrochemical detection of oxidase activityby intermittent pulse amperometry (IPA) of oxidase activity and only 10 minutes are required to perform 96simultaneous measurements. In parallel, in order to harness the 96-well electrochemical system, this detection ofoxidase activity was also carried out in 10 minutes using electrochemiluminescence. This method is more sensitiveand less variable than IPA but is limited to the use of soluble enzymes. However, the reaction conditions are notoptimal for the bienzymatic system (TK-GAOx): long incubation times are required and are poorly adapted for thescreening of TK inhibitors.A second reporter system no longer requiring an auxiliary enzyme and involving only one TK substrate hasbeen optimized. This system relies on the oxidation by ferricyanide of the reactional intermediate resulted of thebinding of the cofactor (thiamine pyrophosphate) and the substrate. This method allows to measure 96 TK activitiesin only 7 minutes and was easily used to screen an in-house chemical library. The screening of 1360 molecules leadto the identification of a new TK inhibitor with an IC50 of 63 μM. This electrochemical system was also used todetermine the mechanism of inhibition (partial non-competitive mechanism) and the associated inhibition constant(3.4 μM). These results are innovative in the field of electrochemistry and offer a wide range of applications forenzymatic activity screening or the screening of enzymes inhibitors
59

Nouvelle forme d'onde et récepteur avancé pour la télémesure des futurs lanceurs

Piat-Durozoi, Charles-Ugo 27 November 2018 (has links) (PDF)
Les modulations à phase continue (CPMs) sont des méthodes de modulations robuste à la noncohérence du canal de propagation. Dans un contexte spatial, les CPM sont utilisées dans la chaîne de transmission de télémesure de la fusée. Depuis les années 70, la modulation la plus usitée dans les systèmes de télémesures est la modulation CPFSK continuous phase frequency shift keying filtrée. Historiquement, ce type de modulation est concaténée avec un code ReedSolomon (RS) afin d'améliorer le processus de décodage. Côté récepteur, les séquences CPM non-cohérentes sont démodulées par un détecteur Viterbi à sortie dure et un décodeur RS. Néanmoins, le gain du code RS n'est pas aussi satisfaisant que des techniques de codage moderne capables d'atteindre la limite de Shannon. Actualiser la chaîne de communication avec des codes atteignant la limite de Shannon tels que les codes en graphe creux, implique deremanier l’architecture du récepteur usuel pour un détecteur à sortie souple. Ainsi, on propose dans cette étude d' élaborer un détecteur treillis à sortie souple pour démoduler les séquences CPM non-cohérentes. Dans un deuxième temps, on concevra des schémas de pré-codages améliorant le comportement asymptotique du récepteur non-cohérent et dans une dernière étape on élabora des codes de parité à faible densité (LDPC) approchant la limite de Shannon.
60

Identification de catalyseurs à l'aide de criblages à haut débit basés sur des techniques immunoenzymatiques

Macovei, Cristian-Paul 05 May 2008 (has links) (PDF)
Le travail décrit dans ce manuscrit présente l'utilisation de deux techniques immunoenzymatiques pour le criblage à haut débit de catalyseurs chimiques et biologiques. Ces méthodes, jusqu'à présent réservées au monde du diagnostic sont employées ici pour la découverte de nouveaux catalyseurs pour des réactions énantiosélectives ainsi que pour des réactions de couplage. Les dosages immunologiques « par compétition » faisant appel aux anticorps monoclonaux se sont avérés des excellents outils pour le criblage à haut débit de catalyseurs asymétriques pour les réactions d'insertion de carbénoïdes dans la liaison OH de l'eau tandis que celles utilisant des anticorps polyclonaux ont été utilisées avec succès pour le criblage de biocaytalyseurs pour la réaction d'ouverture énantiosélective des oxazolones par l'eau. Un autre type de méthode utilisant des anticorps monoclonaux, appelée « sandwich » nous a permis de réaliser le criblage à haut débit de catalyseurs pour la réaction de cycloaddition alcyne-azoture.

Page generated in 0.0255 seconds