• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 85
  • 13
  • 10
  • Tagged with
  • 109
  • 34
  • 27
  • 22
  • 15
  • 14
  • 14
  • 13
  • 13
  • 13
  • 12
  • 12
  • 12
  • 11
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Contribution à la Perception Visuelle Basée Caméras Grand Angle pour la Robotique Mobile et Les Véhicules Autonomes / Contribution to wide angle visual perception for mobile robots and self driving cars

Khomutenko, Bogdan 15 June 2018 (has links)
Ce travail de thèse présente un nouveau modèle de projection pour les cameras fisheye, qui est mathématiquement simple et pourtant montre une haute précision une fois appliqué aux caméras réelles. Les propriétés géométriques de ce modèle ont été analysées en utilisant le concept de surface de projection, introduit dans ce travail. En particulier, une inverse analytique de ce modèle a été établie, ainsi qu'une équation implicite des projections de lignes droites. Cette dernière nous a permis de développer une méthode de reconstruction 3D directe basée vision pour les caméras fisheye sans rectifier les images. Cela a été fait grâce à une algorithme de rastérisation de courbes implicites. Cet algorithme de reconstruction nous permet d'employer le Semi-Global Matching pour obtenir une reconstruction 3D précise. Tous ces éléments ont été employés dans un système de localisation visuelle directe avec deux méthodes de recalage d'images : minimisation d'erreur photométrique et maximisation d'information mutuelle. L'étalonnage intrinsèque et extrinsèque d'un robot mobile équipé de caméras fisheye a été considéré et une toolbox d'étalonnage a été développée. / This thesis presents a novel projection model for fisheye cameras, which is mathematically simple and yet shows a high precision when applied to real cameras. Geometric properties of the model have been analyzed using the concept of projection surface, introduced in this work. In particular, a closed-form inverse mapping and an implicit equation for straight line projection have been found. This fact has been used to develop a method of direct stereo correspondence on raw fisheye images via rasterization of implicit curve. This correspondence algorithm allows us to apply the Semi-Global Matching algorithm to get an accurate 3D reconstruction using fisheye stereo systems. All these elements have been shown to be applicable to a direct visual localization system with two different methods of image registration: direct photometric error minimization and mutual information maximization. Intrinsic and extrinsic calibration of a mobile robot with fisheye cameras has been considered and a toolbox for such a calibration has been developed.
32

Détection de rails, caractérisation de croisements et localisation de trains sur la trajectoire d'un métro automatique / Rails detection, turnouts characterisation and trains localization in an automated metro's trajectory

Corsino Espino, Jorge 13 June 2014 (has links)
Cette thèse porte sur la fonction de détection d'obstacles dans le domaine ferroviaire à partir de la vision par ordinateur. Il s'agit d'assurer une perception de l'environnement situé à l'avant du train afin de détecter et d'évaluer les distances des obstacles situés sur la voie.Nous avons donc proposé un module détection de rails à partir des images à niveaux de gris, pour déterminer une zone libre d'obstacles à l'avant du train. Cette détection est basée dans l'algorithme de RANSAC et une estimation de la voie par un polynôme de degré 2. Elle s'est montrée robuste à notre base de données et a permis de détecter les rails à des distances supérieures à la distance d'arrêt. Aussi, un algorithme d'étalonnage des caméras installées dans le train a été proposé à partir de la morphologie de la voie.Comme support de la reconnaissance de rails, nous présentons un module de détection et classification des appareils de voie basé dans le descripteur HOG extrait des images IPM (Inverse Perspective Mapping). Un classifieur SVM (Support Vector Machines) binaire a été utilisé pour la détection et un SVM multi-classe pour différencier les appareils de voie existants sur la ligne.Après avoir élaboré le module de détection des rails, nous avons implémenté un détecteur de trains. À partir d'un échantillon des images de trains de la ligne en question et des images négatives comme des voitures ou des bus, nous avons créé une base de données d'obstacles pour trouver un descripteur robuste qui arrive à décrire la forme des trains et permet à un classifieur SVM de discriminer les images et détecter les trains. Par la suite, ce classifieur est utilisé par le système global pour déterminer la présence d'un train au-delà de la détection de la voie. À la distance maximale de détection, un rectangle de la taille d'un train est extrait de l'image pour vérifier la présence d'un train. Ces rectangles font l'objet d'une classification au moyen de descripteurs globaux de type HOG et une structure SVM binaire.Cette étude permettra non seulement de déboucher sur des applications concrètes, mais surtout d'évaluer la maturité des technologies de traitements d'images pour réaliser des fonctions sûres appliquées aux systèmes ferroviaires. / This thesis deals with obstacle detection in a railway setting using computer vision. The main task is to provide perception of the environment in front ofthe train using an optical sensor to detect and evaluate distances to obstacles along the track path.We present a module for detecting rails from grayscale images to determine an obstacle-free zone in front of the train. This detection is based on the RANSACalgorithm and fitting the track to a second degree polynomial. The method has shown itself robust to our dataset and allows detecting the rails at distancesgreater than the emergency stopping distance. In addition, a method for calibrating the cameras installed on the train is proposed based on the morphology ofthe track.To supplement rail detection, we present a new module for detecting and classifying junctions based on the HOG descriptor extracted from InversePerspective Mapping (IPM) images. A Support Vector Machines (SVM) binary classifier was used for detection and a multi-class SVM for distinguishing ofjunctions along the rails.In the sequel, a train detector was implemented. Using a set of images of trains found on the studied line and negative images such as cars or buses, we havecreated a database of obstacles to find a robust descriptor which is able to model the form of trains and allows a SVM classifier to distinguish images anddetect trains. Next this classifier is used by the overall system to determine the presence of a train in addition to detecting rails. At the maximum detectiondistance, a train-sized rectangle is extracted from the image in order to confirm the presence of a train. These rectangles are classified by means of HOG-typeglobal descriptors and a binary SVM structure.In addition to its applications to concrete problems, this study permits to evaluate the maturity of image processing technologies forfail-safe railway systems.
33

Etude des vestiges de supernova en intéraction avec l'expérience d'astronomie H.E.S.S. et étalonnage de la caméra H.E.S.S. II / Study of supernova interacting with molecular clouds with H.E.S.S. and calibration of the H.E.S.S. II camera

Fernandez Gangoso, Diane 30 September 2014 (has links)
La découverte du rayonnement cosmique remonte à plus d'un siècle, mais son origine est encore incertaine aujourd'hui. Divers éléments théoriques et observationnels tendent à confirmer que les vestiges de supernova (SNRs) sont à l'origine de la majeure partie du rayonnement cosmique galactique jusqu'à des énergies de ~3 PeV, voire au-delà. Mais ce paradigme requiert encore une preuve irréfutable.Lors de l'expansion d'un SNR, les particules chargées du milieu circumstellaire/interstellaire sont accélérées par l'onde de choc et peuvent alors rayonner depuis le domaine radio jusqu'aux très hautes énergies (>100 GeV). Les mécanismes d'accélération et les processus d'émission des particules ont été étudiés et modélisés au cours de cette thèse.Les instruments d'astronomie Gamma permettent de détecter les rayonnements émis par les particules accélérées au choc des SNRs. En particulier, le télescope à création de paires Fermi-LAT et le réseau de télescopes au sol à imagerie Tcherenkov atmosphérique H.E.S.S. détectent, à eux deux, des photons Gamma d'énergie comprise entre ~30 MeV et plusieurs dizaines de TeV. Au cours de cette thèse, réalisée dans le cadre de l'expérience H.E.S.S., les données observationnelles de plusieurs SNRs ont été analysées et interprétées. Les études menées ont conduit à la détection d'une des sources les plus faibles encore jamais détectée et dont l'émission Gamma est associée à l'interaction du SNR G349.7+0.2 avec un nuage moléculaire adjacent. Des limites supérieures sur les flux intégrés de nombreux SNRs ont été extraites afin de contraindre les modèles d'accélération de particules. Le SNR Puppis A présente notamment un comportement spectral inattendu, difficile à expliquer dans le cadre des modèles d'accélération de particules actuels.Un cinquième télescope, de plus grande taille, a été ajouté mi-2012 au réseau de quatre petits télescopes H.E.S.S. afin d'abaisser le seuil en énergie et d'améliorer la sensibilité du réseau. Dans ce cadre, j'ai activement participé au développement, à l'intégration et à l'analyse des données du dispositif d'étalonnage de la caméra de ce cinquième télescope. / The discovery of Cosmic Rays (CRs) dates back more than one century ago, however their origin remains unclear. There is rather convincing evidence that the bulk of Galactic CRs, up to ~3 PeV, and possibly beyond, is accelerated in supernova remnants (SNRs). However this paradigm still needs a conclusive proof. While the SNR expands, charged particles from the circumstellar/interstellar medium are accelerated at the SNR shock wave and radiate from radio to very high energies (>100 GeV). Particles acceleration and broad band radiation mechanism were studied and modelled during this PhD. $gamma$-ray astronomy instruments enable to detect radiation from particles accelerated at the SNR shock wave. In particular the pair creation telescope Fermi-LAT and the array of imaging atmospheric Cherenkov telescopes H.E.S.S., enable together to detect Gamma-ray photons in the ~30 MeV-30 TeV energy range. As a member of the H.E.S.S. collaboration, I analysed and interpreted observational data from several Galactic SNRs. These studies led to the discovery of one of the faintest sources ever detected whose Gamma-ray emission is associated with the interaction of the SNR G349.7+02 with an adjacent molecular cloud. Upper limits on the integrated flux of many SNRs were extracted in order to constrain models of particle acceleration. In particular, the SNR Puppis A shows an unexpected spectral behavior difficult to explain with current models. A fifth bigger telescope was added mid 2012 to the H.E.S.S. array of four small telescopes to lower the energy threshold and to improve the sensitivity of the array. In this context I actively participated to the development, integration end data analysis of the calibration hardware of the camera of this fifth telescope.
34

Couplage lidar Raman et GPS pour le sondage de la vapeur d'eau atmosphérique et le positionnement précis / Raman lidar and GPS coupling for atmospheric water vapor measurement and accurate positioning

David, Leslie 04 December 2015 (has links)
Développé initialement pour la correction du retard humide des signaux GPS, le lidar Raman vapeur d’eau de l’Institut National de l’information Géographique et forestière (IGN) pourrait aujourd’hui servir pour d’autres applications telles que la climatologie et la météorologie. Cependant, quelle que soit l’application visée, il est primordial d’assurer une très bonne précision de la mesure. Un étalonnage fiable et stable de l’instrument est alors requis. Lors de la dernière campagne de mesures (Démévap) qui consistait à inter-comparer différentes techniques d’étalonnage, une dérive du coefficient d’étalonnage du lidar a été observée. Ce travail revient alors sur cette dérive et explore, dans un premier temps, les signaux enregistrés durant cette campagne. En découle alors un inventaire de sources d’erreurs et de variations pouvant expliquer ces résultats. Trois sources majeures de variations seront ensuite étudiées de manière approfondie : la dépendance en température des sections efficaces Raman induite par l’usage de filtres étroits, l’impact du choix des optiques de transmission et détection du signal et les problèmes liés à l’électronique de détection. À l’aide de simulations numériques, modélisations et tests en laboratoire, on s’est efforcés de mettre en évidence et de quantifier les variations. Des solutions permettant de minimiser ces instabilités ont aussi été proposées et testées. Finalement, le système lidar a été remonté entièrement et une campagne de validation des améliorations a été menée à Saint-Mandé. Sur une période de cinq mois, on a pu contrôler la stabilité instrumentale et étudier l’étalonnage du lidar à l’aide de capteurs d’humidité placés au sol. / The IGN (Franch Mapping Institut) water vapor Raman lidar has been developed in order to correct the wet delay of GPS signals. Today, the goal is to open up to other applications such as meteorology and climatology. Regardless the applications, high accuracy is and will be completed with a reliable calibration of the instrument. The latest campaign, during which the IGN Raman was experimented, was Demevap. Several lidar calibration techniques were compared, and results showed a common drift all along the campaign. The work presented here starts with a detailed investigation of the Demavap absolute signals. This first step allowed listing different likely sources of errors and instabilities in the system which lead to fluctuations of the calibration coefficient. Among them, we chose to study thoroughly three subsystems which appear to have a major influence on the calibration coefficient variations: the temperature dependence of the Raman cross sections induced by the use of narrowband interference filters, the effect of the optical configuration of the detection part of the lidar and problems linked to the electronic part of the detection. We strive to highlight and quantify the variations by means of numerical simulations, models and laboratory experiments. Furthermore, we proposed theoretical, empirical and instrumental solutions for the mitigation of these variations. Eventually, long term calibration coefficient stability of the overall system will be assessed with regular water vapor profile recordings and calibration measurements spread over several months.
35

Étalonnage d'un instrument d'observation spatial actif / Calibration of an active space telescope

Gayral, Thibault 29 November 2013 (has links)
Une nouvelle architecture robotique parallèle de télescope d'observation spatial actif a été développée préalablement à cette thèse. Afin de pouvoir améliorer le réglage optique du télescope, la structure robotique doit pouvoir être auto-étalonnée dans l'espace, à partir des informations disponibles (mesures proprioceptives, images, etc). Dans un premier temps, les hypothèses nécessaires pour assurer le bon déroulement de l'étalonnage sont analysées. Cette étude théorique, appuyée par des exemples, permet de définir des conditions nécessaires à l'étalonnage. Ces conditions permettent de déterminer les précisions nécessaires sur les paramètres du modèle et l'amplitude maximale du bruit de mesure admissible pour l'étalonnage. Avec ces valeurs, un critère d'arrêt pour les algorithmes d'étalonnage ayant une réelle signification physique peut être obtenu. De plus, une normalisation de la matrice d'identification est proposée, ce qui permet l'analyse de ses valeurs singulières pour détecter les problèmes d'identifiabilité des paramètres. Dans une deuxième partie, nous nous intéressons à la modélisation du télescope d'observation. Plusieurs modèles de déformation des articulations flexibles du télescope sont proposés, en considérant par exemple les équations de la théorie des poutres ou l'équilibre statique de la plate-forme. Ces modèles sont ensuite comparés expérimentalement par une analyse des résultats d'étalonnage photogrammétrique. Cette analyse permet aussi d'observer une déformation de la plate-forme mobile qui peut être approchée par l'intermédiaire de deux modèles. / A new parallel robotic architecture has previously been developed for an active space telescope. The telescope needs to be calibrated in order to improve its optical quality. This also has to be done automatically in space with the available information (propriocetive measures, images, etc) which is referred as self-calibration. First, the necessary hypothesis for calibration are analyzed. This theoretical study, illustrated with examples, leads to the definition of the necessary conditions for an efficient calibration. With those conditions, the required accuracy of the model parameters and the maximal measurement noise allowed for calibration can be calculated. A physically meaningful stop criterion for the identification algorithm can also be derived and a normalization of the identification Jacobian matrix is proposed, which permits the analysis of its singular values in order to detect identifiability problems. Concerning the telescope modeling, three kinematic models taking into account the telescope flexure joint behaviors are proposed, for example using the beam theory or the static equilibrium of the mobile platform. Those models are compared through an analysis of the calibration results using photogrammetry. This analysis highlights a deformation of the mobile platform of the telescope, that was considered using two models. Thus, the kinematic model of the telescope is composed of both a model for the flexure joints and a model approaching the mobile platform deformation. This model was validated with the calibration results of photogrammetry.
36

Étalonnage automatique des détecteurs pour scanner LabPET II

Jürgensen, Nadia January 2017 (has links)
Depuis une vingtaine d'années, le GRAMS et le CIMS travaillent en collaboration dans le domaine de l'imagerie médicale, plus précisément sur la tomographie d'émission par positrons destinée à la recherche préclinique sur petits animaux. Après le scanner TEP Sherbrooke en 1994 et le LabPET I commercialisé par Advanced Molecular Imaging (AMI) Inc., Gamma Medica Ideas et GE Healthcare au cours des années 2000, l'aspiration vers de meilleures performances est le moteur de la réalisation d'une nouvelle version : le LabPET II. L'augmentation importante du nombre de détecteurs, nécessaire pour atteindre une meilleure résolution spatiale, amène de nouveaux défis autant sur le plan matériel que logiciel. Un des défis est de compenser les disparités en gain des détecteurs à base de photodiodes à avalanche (PDA) qui engendrent des différences intercanaux. Le but de ce projet de maîtrise est de développer et d'implémenter un algorithme capable de corriger ces différences de façon automatisée.
37

Analyse d’aérosols par méthodes LIBS sans étalonnage et LIBS couplée à une cellule radiofréquence utilisée comme piège à particules / Aerosols analysis using calibration-free LIBS technic and LIBS technic coupled to a low-pressure RF-plasma cell used as particles trap

Boudhib, Mohamed 31 March 2017 (has links)
Pour répondre aux besoins des nouvelles techniques de caractérisation sur site in-situ et temps réel, l’unité NOVA de l’INERIS en partenariat avec les laboratoires LP3 et GREMI, a entamé des travaux pour étudier deux approches afin d’améliorer les performances de la technique Laser-Induced Breakdown Spectroscopy (LIBS) pour l’analyse des aérosols. LIBS est une technique optique de spectroscopie atomique. Elle consiste à focaliser un faisceau laser impulsionnel sur un échantillon à analyser créant ainsi un plasma. L’émission optique du plasma contient alors la signature des éléments chimiques présents dans l’échantillon. La première approche concerne la détermination de la composition chimique relative (stoechiométrique) d’aérosols sans étalonnage. En effet, l’étalonnage présente des problèmes pratiques. Pour ce faire, les spectres expérimentaux enregistrés lors de l’analyse des particules d’alumine (Al2O3) suspendues dans de l’hélium (He) ont été comparés à des spectres théoriques calculés pour un plasma contenant les mêmes éléments, à l’Équilibre Thermodynamique Local (ETL). L’ajustement des spectres simulés sur les spectres expérimentaux nous a permis de déterminer correctement la composition chimique relative des éléments présents dans le plasma. L’évolution temporelle du plasma a permis de valider l’ETL, et ainsi estimer la meilleure plage temporelle permettant la détermination de la composition relative de l’aérosol. La deuxième approche utilise une cellule radiofréquence (RF) à pression réduite comme piège à particules pour analyser des aérosols contenant des nanoparticules. Un tel piège permet d’améliorer la détection en concentrant spatialement les particules. Les paramètres optimaux d’utilisation de ce système ont été étudiés. Cette étude a permis d’établir que l’émission continue du plasma est fortement réduite dès ses premiers instants de vie. Le volume d’échantillonnage de ce système a été évalué et la limite de détection a été estimée de manière théorique. / New issues related to process control and workplace surveillance accompany the emergence of nanotechnology industry. This involves the development of new real-time and in-situ characterization techniques. In this context, the NOVA unit from the INERIS institute collaborated with LP3 and GREMI laboratories to study two approaches aiming to enhance the LIBS technic performances. The first approach used a flow cell to determine the relative elemental composition of an aerosol with a calibration-free procedure. The recorded spectra were compared to theoretical spectra calculated for a plasma in the Local Thermodynamic Equilibrium LTE. The best agreement between recorded and computed spectra allowed the determination of the relative composition with a good agreement with the reference value, for an alumina aerosol. The study of the temporal evolution of the plasma allowed the estimation of a temporal range within which the LTE hypothesis was verified. The second approach used a low-pressure radiofrequency plasma generated in an inert gas as a particle trap to analyse aerosols and nanoparticles. The use of such a system allowed the enhancement of particles detection by concentrating them spatially. We determined the optimal parameters for the LIBS analysis using this system. Furthermore, we established the plasma continuum was attenuated even at very low time delays. We evaluated the sampling volume of this new system and compared it to case of LIBS analysis on air. Finally, we estimated the detection limits of this system when analysing nanoparticles.
38

Caractérisation et étalonnage de la caméra de l'expérience ballon PILOT (Polarized Instrument for Long wavelength Observation of the Tenuous interstellar medium) / Caracterization and calibration of the camera of the PILOT balloon born experiment (Polarized Instrument for Long wavelength Observation of the Tenuous interstellar medium)

Buttice, Vincent 30 September 2013 (has links)
PILOT (Polarized Instrument for Long wavelength Observation of the Tenuous interstellar medium) est une expérience embarquée en ballon stratosphérique destinée à la mesure de l'émission polarisée de notre galaxie dans le submillimétrique. La charge pointée de PILOT est composée d'un télescope au foyer duquel est placée une caméra embarquant 2048 bolomètres, refroidis à 300 mK, mesurant dans deux bandes spectrales (240 µm et 550 µm) et deux polarisations. La détection de la polarisation est réalisée à l'aide d'un polariseur placé à 45° dans le faisceau, le décomposant en deux composantes polarisées orthogonales chacune détectée par un bloc détecteur, et d'une lame demi-onde rotative. L'Institut d'Astrophysique Spatiale (Orsay, France) est responsable de la réalisation, de l'intégration, des tests et de l'étalonnage spectral de la caméra. Pour cela deux bancs de mesures sont développés, un pour les essais d'imagerie et de polarisation, et un pour l'étalonnage spectral. L'expérimentation permet de valider l'alignement des optiques froides, de caractériser la qualité optique des images, de caractériser les réponses temporelles et en intensité des détecteurs, et de mesurer la réponse spectrale de la caméra. Un modèle photométrique de l'instrument est développé simulant les différentes configurations pour les essais d'étalonnage spectral, d'imagerie en laboratoire, et en vol, ceci afin d'estimer la puissance totale reçue par chaque pixel du détecteur de chaque configuration. Cette puissance totale est issue de l'émission thermique de l'instrument, de l'atmosphère et des sources observées en vol ou de l'environnement du laboratoire. Une campagne de tests a permis de caractériser et d'étalonner la caméra de l'expérience PILOT. Les premières images dans le domaine du submillimétrique ont été révélées, et les premières réponses spectrales mesurées. Suite à la caractérisation et l'étalonnage spectral, la caméra est alignée avec le miroir primaire sur la nacelle CNES pour des caractérisations et des étalonnages en polarisation de l'instrument complet. Le premier vol est prévu pour le milieu de l'année 2014. / The Polarized Instrument for Long wavelength Observation of the Tenuous interstellar medium (PILOT) is a balloon borne experiment designed to measure the polarized emission from dust grains in the galaxy in the submillimeter range. The payload is composed of a telescope at the optical focus of which is placed a camera using 2048 bolometers cooled to 300 mK. The camera performs polarized optical measurements in two spectral bands (240 µm and 550 µm). The polarization measurement is based on a cryogenic rotating half-wave plate and a fixed mesh grid polarizer placed at 45° separating the beam into two orthogonal polarized components each detected by a detector array. The Institut d'Astrophysique Spatiale (Orsay, France) is responsible for the design, integration, tests and spectral calibration of the camera. Two optical benches have been designed for its imaging and polarization characterization and spectral calibration. Theses setups allow to validate the alignment of the camera cryogenic optics, to check the optical quality of the images, to characterize the time and intensity response of the detectors, and to measure the overall spectral response. A numerical photometric model of the instrument was developed for the optical configuration during calibration tests (spectral), functional tests (imager) on the ground, and flight configuration at the telescope focus, giving an estimate of the optical power received by the detectors for each configuration. The tests campaign validates the PILOT camera characterization and calibration. It delivered the first submillimeter images and the first spectral responses. Next, the camera will be aligned and integrated with the primary mirror of the telescope on the CNES gondola, for characterization and optical polarization calibration of the complete instrument. The first flight is now planned for mid 2014.
39

Applicabilité à domicile d'une batterie d'évaluation mesurant les résultats de la réadaptation gériatrique

Auger, Claudine January 2005 (has links)
Mémoire numérisé par la Direction des bibliothèques de l'Université de Montréal.
40

Conception, modélisation et étalonnage d'un shunt pour la mesure de courant à 10 A et 1 MHz / Design, modeling and calibration of a shunt for current measurement at 10 A and 1 MHz

Ouameur, Mohamed 18 January 2019 (has links)
Mesurer des forts courants alternatifs sur une large bande de fréquences est primordial pour de nombreuses applications dont la surveillance du réseau de distribution électrique et le développement des véhicules électriques. Dans le premier cas, la mesure du courant est nécessaire pour quantifier la qualité du réseau en présence d’harmoniques provenant des énergies renouvelables intermittentes dont le spectre en fréquences est assez large (plusieurs centaines de kilohertz). Dans le second cas, la mesure du courant (jusqu’à plusieurs dizaines d’ampères) intervient dans la quantification du rendement de la chaîne de traction d’un moteur électrique : dans la mesure du courant la prise en compte d’un grand nombre d’harmoniques (jusqu’à 1 MHz) est indispensable pour garantir une connaissance précise du rendement du moteur. Des résistances de faibles valeurs, appelées « shunt », sont alors indispensables pour mesurer des forts courants. Les shunts sont largement utilisés comme étalon de résistance dans les laboratoires de métrologie et les instruments de précision. Leur utilisation nécessite la connaissance préliminaire en fonction de la fréquence des deux paramètres suivants : déphasage de l’impédance du shunt ; variation relative du module de l’impédance du shunt par rapport à la sa valeur de sa résistance en courant continu, ce paramètre est appelé “écart de transposition”. Pour un niveau de courant de 10 A, l’impédance des shunts existants présente de fortes variations en module et phase pour les fréquences supérieures à 100 kHz. De plus, actuellement dans les laboratoires nationaux de métrologie, pour étalonner les shunts au-delà de 1 A les méthodes de mesure utilisées sont d’une part limitées en module à 100 kHz et en phase à 200 kHz et d’autre part elles donnent accès uniquement à un des deux paramètres : module ou phase de l’impédance du shunt. Ce travail de thèse a pour objectif d’étendre jusqu’à 10 A et 1 MHz les possibilités d’étalonnage des capteurs de forts courant et d’améliorer ainsi la traçabilité des mesures en courant alternatif. Nous avons dans un premier temps développé un shunt étalon de 10 A dont la réponse électromagnétique (jusqu’à 10 MHz) et la réponse thermique sont entièrement calculables : à 1 MHz le déphasage et l’écart de transposition sont respectivement de -0,01 mrad et 15 ppm. Dans un second temps, nous avons mis au point une méthode d'étalonnage traçable permettant de mesurer les shunts jusqu’à 10 MHz. La méthode de mesure, basée sur l'utilisation d'un analyseur de réseau vectoriel, permet de mesurer simultanément l’écart de transposition et la phase de l'impédance d'un shunt avec des incertitudes relatives inférieures à 1.10⁻³ à 1 MHz. / Measuring high alternating currents over a wide frequency bandwidth is essential for many applications including the monitoring of the electrical distribution network and the development of electric vehicles. In the first case, current measurement is necessary to quantify the quality of the grid in the presence of harmonics from intermittent renewable energies with a large frequency spectrum (several hundred kilohertz). In the second case, current measurement (up to several tens of amperes) is used to quantify the efficiency of an electric motor's traction chain: in current measurement, it is essential to take into account a large number of harmonics (up to 1 MHz) to ensure an accurate knowledge of the motor's efficiency. Resistors of low values, called "shunt", are then mandatory to measure high currents. Shunts are widely used as a resistance standard in metrology laboratories and precision instruments. Their use requires the preliminary knowledge of the following two parameters according to the frequency: Impedance phase shift; relative variation of the impedance magnitude according to its DC resistance value, this parameter is called “AC-DC difference”. For a current level of 10 A, the impedance of existing shunts shows strong variations in magnitude and phase for frequencies above 100 kHz. In addition, in National Metrology Institutes, to calibrate shunts beyond 1 A the measurement methods currently used are limited in magnitude up to 100 kHz and phase up to 200 kHz; and provide access to only one of the two parameters: magnitude or phase of impedance. The aim of this thesis is to extend the calibration capabilities of high current sensors up to 10 A and 1 MHz and thus improve the traceability of AC current measurements. Firstly, we developed a 10 A shunt standard whose electromagnetic (up to 10 MHz) and thermal responses are fully calculable: at 1 MHz the phase shift and transposition deviation are -0.01 mrad and 15 ppm respectively. Secondly, we developed a traceable calibration method to measure shunts up to 10 MHz. The measurement method, based on the use of a vector network analyzer, allows the AC-DC deviation and impedance phase of a shunt to be measured simultaneously with relative uncertainties less than 1.10⁻³ at 1 MHz.

Page generated in 0.4214 seconds