Spelling suggestions: "subject:"óptica"" "subject:"ópticas""
231 |
Correlação entre o eletrorretinograma de padrão reverso, a tomografia de coerência óptica e a perimetria automatizada na detecção da perda neural na atrofia em banda do nervo óptico / Relationship between pattern electroretinogram, optical coherence tomography and automated perimetry for detection of neural loss in eyes with band atrophy of the optic nerveLeonardo Provetti Cunha 09 August 2010 (has links)
OBJETIVO: Avaliar a capacidade dos parâmetros do eletrorretinograma de padrão reverso de campo total e hemianópico em diferenciar olhos com atrofia em banda do nervo óptico e, a correlação entre as amplitudes do eletrorretinograma de padrão reverso, a espessura da camada de fibras nervosas da retina e macular obtidas pela tomografia de coerência óptica e a perda de campo visual nestes pacientes. MÉTODOS: Quarenta e um olhos de 41 pacientes com perda de campo visual temporal permanente por compressão do quiasma óptico e 41 controles normais foram submetidos ao eletrorretinograma de padrão reverso de estimulação de campo total e hemianópicos (temporal e nasal), a tomografia de coerência óptica, para avaliação das medidas da espessura da camada de fibras nervosas da retina e macular e, ao exame de campo visual, pela perimetria automatizada padrão. O desvio do normal da sensibilidade dos 18º centrais do campo visual foram expressos em decibéis e unidades 1/Lambert. As comparações foram feitas pelo teste t de Student. A correlação entre os parâmetros do campo visual central, do eletrorretinograma de padrão reverso e da tomografia de coerência óptica foi avaliada pela correlação de Pearson e análise de regressão linear. RESULTADOS: Os valores das amplitudes P50, N95, and P50+N95 do eletrorretinograma de padrão reverso de campo total, e de estimulação hemianópica e os valores das medidas da espessura macular e da camada de fibras nervosas da retina obtidas pela tomografia de coerência óptica foram significativamente menores nos olhos com atrofia em banda do que nos controles (P<0,001). Uma correlação significativa foi encontrada entre a perda de sensibilidade no campo visual central e as amplitudes do eletrorretinograma de padrão reverso de estimulação de campo total e nasal, mas não para o temporal. Uma correlação significativa positiva foi observada entre os parâmetros de perda de sensibilidade no campo visual e a maioria dos parâmetros da espessura da camada de fibras nervosas da retina e macular obtidas pela tomografia de coerência óptica. Nenhuma correlação significativa foi observada entre os parâmetros do eletrorretinograma de padrão reverso e a tomografia de coerência óptica, exceto para amplitude P50+N95 do eletrorretinograma de padrão reverso de estimulação de hemicampo nasal. Uma correlação significativa foi observada entre os parâmetros de espessura macular e da camada de fibras nervosas pela tomografia de coerência óptica, exceto entre a espessura da camada de fibras nervosas no segmento de 30º, correspondente as 9 horas do relógio e os parâmetros maculares. CONCLUSÕES: Os valores das amplitudes do eletrorretinograma de padrão reverso foram eficazes em diferenciar olhos com atrofia em banda do nervo óptico de controles normais. Em pacientes com atrofia em banda do nervo óptico, as amplitudes do eletrorretinograma de padrão reverso e medidas da espessura da camada de fibras nervosas da retina e macular correlacionaram de forma significativa com a perda de campo visual, mas não houve correlação entre eles. O eletrorretinograma de padrão reverso e a tomografia de coerência óptica detectaram a perda neural e ambos são métodos diagnósticos úteis na compreensão da correlação estrutura-função em pacientes com compressão do quiasma óptico / PURPOSE: To evaluate the ability of full-field and hemifield pattern electroretinogram parameters to differentiate between healthy eyes and eyes with band atrophy of the optic nerve and also to evaluate the relationship between pattern electroretinogram amplitude, macular and retinal nerve fiber layer thickness by optical coherence tomography, and visual field loss on standard automated perimetry in eyes with BA of optic nerve. METHODS: Forty-one eyes from 41 patients with permanent temporal visual field defects from chiasmal compression and 41 healthy subjects underwent transient fullfield and hemifield (temporal or nasal) stimulation pattern electroretinogram, standard automated perimetry and time domain- optical coherence tomography macular and retinal nerve fiber layer thickness measurements. Comparisons were made using Students t-test. Deviation from normal visual field sensitivity for the central 18° was expressed in dB and 1/Lambert units. Correlations between measurements were verified by Pearsons correlations and linear regression analysis. RESULTS: Full-field P50, N95, and P50+N95 amplitude values were significantly smaller in eyes with band atrophy than in control eyes (P<0.001). Nasal and temporal hemifield pattern electroretinogram studies revealed significant differences in N95 and P50+N95 amplitudes measurements. Pattern electroretinogram and optical coherence tomography measurements were significantly lower in eyes with temporal hemianopia than in normal eyes. A significant correlation was found between visual field sensitivity loss and full-field or nasal, but not temporal, hemifield pattern electroretinogram amplitude. Likewise a significant correlation was found between visual field sensitivity loss and most optical coherence tomography parameters. No significant correlation was observed between optical coherence tomography and pattern electroretinogram parameters, except for nasal hemifield amplitude. A significant correlation was observed between several macular and retinal nerve fiber layer thickness parameters. CONCLUSIONS: Transient pattern electroretinogram amplitude measurements were efficient at differentiating eyes with band atrophy and permanent visual field defects from normal controls. In patients with chiasmal compression, pattern electroretinogram amplitude and optical coherence tomography thickness measurements were significant related to visual field loss, but not to each other. Pattern electroretinogram and optical coherence tomography quantify neuronal loss differently, but both technologies are useful in understanding structure-function relationship in patients with chiasmal compression
|
232 |
Análise teórica de uma nova técnica de processamento de sinais interferométricos baseada na modulação triangular da fase ópticaTakiy, Aline Emy [UNESP] 30 November 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:22:31Z (GMT). No. of bitstreams: 0
Previous issue date: 2010-11-30Bitstream added on 2014-06-13T20:49:10Z : No. of bitstreams: 1
takiy_ae_me_ilha.pdf: 1702331 bytes, checksum: b89d2b4960ee7bbc0e01a3a5d3e7a2be (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Neste trabalho estuda-se a interferometria laser, a qual constitui uma técnica adequada para determinar grandezas físicas com sensibilidade extremamente elevada. Basicamente, no interferômetro óptico, a informação a respeito do dispositivo sob teste é inserida na fase da luz. Utilizando-se o fotodiodo, promove-se a transferência de informação, do domínio óptico para o elétrico, no qual pode ser demodulada usando-se as várias técnicas disponíveis na literatura para detectar sinais modulados em fase. Ênfase é dada a um novo método de demodulação de fase óptica auto-consistente e de grande sensibilidade. Neste método, utiliza- se a modulação dada por uma forma de onda triangular e é baseado na análise do espectro do sinal fotodetectado, sendo capaz de estender a faixa dinâmica de demodulação a valores tão elevados quanto às dos métodos clássicos. Simulações dinâmicas computacionais de interferômetros ópticos são executadas em Simulink juntamente com este método, levando-se em consideração tensões de ruído eletrônico do tipo ruído branco, evidenciando a eficiência do método quando comparados com dados teóricos obtidos em Matlab. A validação experimental do método é realizada com o auxílio de um modulador eletro-óptico de amplitudes, cujas características de fase podem ser previstas analiticamente. Trata-se de um sensor polarimétrico baseado em cristal de Niobato de Lítio, em que a diferença de fase óptica induzida pela tensão elétrica aplicada pode ser determinada através de análise espectral, tal como o novo método descrito neste trabalho. Um interferômetro de Michelson homódino de baixo custo é implementado e a eficiência do novo método de demodulação de fase óptica é avaliada através de testes com atuadores e manipuladores piezoelétricos flextensionais, cujas características de linearidade são conhecidas... / In this work, has been done a study the laser interferometer, which is a technique for determining physical quantities with extremely high sensitivity. Basically, in the optical interferometer, information about the device under test modulates the phase of light. Using a photodiode, promotes the transfer of information from the optical domain for the electric, which can be demodulated using the various techniques available in literature to detect modulated signals in phase. Emphasis is given to a new method of phase demodulation of optical self-consistent and high sensitivity. The method employs a linear modulation given by a triangular waveform, and is based on analysis of the spectrum of the photodetected signal, being able to extend the dynamic range of the demodulation values as high as the classical methods. Dynamic computational simulations of optical interferometers are implemented in Simulink with this method, taking into account strains of electronic noise like white noise, indicating the efficiency of the method compared with theoretical data obtained in Matlab workspace. The experimental validation of the method is performed with the aid of an electro- optic amplitude modulator, whose phase characteristics can be analytically predicted. This is a polarimetric sensor based on lithium niobate crystal, in which the optical phase difference induced by electric voltage can be determined by spectral analysis, using new method described in this work. A low cost homodyne Michelson interferometer is implemented and the efficiency of the new method of optical phase demodulation is evaluated by testing with piezoelectric flextensional actuators whose characteristics of linearity are well known.The experimental results agree with theoretical analysis and reveal this method is more efficient than the classical methods
|
233 |
Fertilização nitrogenada à dose variada na cultura do milho / Variable-rate nitrogen fertilization in maizeBragagnolo, Jardes 25 February 2014 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Maize is the main cereal produced in Brazil, being highly responsive to nitrogen fertilization, since the tropical and subtropical soils presents insufficient availability of nitrogen (N) to attend the culture demand in order to obtain high yields. Adjustments in the rate of N fertilizer can be made during the development of the culture through of the use of optical sensors spectrometry. The aim of this study was to evaluate the efficiency of nitrogen fertilization to the variable rate prescribed by use of the N -Sensor® ALS, and correlate it with different plant attributes during development of maize in RS Oxisols. Three experiments were conducted, two in the 2008/09 and another in the 2010/11 season. The ability of the sensor to determine the nutritional status of the culture and the effect of different rates of N, uniform and variable rate, on the following attributes of the plant were evaluated: N content of the plant tissue, the total N uptake by the crop, dry matter and relative chlorophyll content measured by chlorophyll meter readings with manual and on grain yield and N use efficiency. The plant attributes and corn yield were largely influenced by nitrogen fertilization and the intrinsic climatic conditions of each experiment. During fertilization optical sensor was able to assess on average 34 % of the plants in the experimental areas, which obtained high ratio of the readings of the optical sensor with the amount of N uptake and dry matter of corn plants, despite loss efficiency (saturation) observed in the later stages of crop development. Whereas maize absorbed most of the N after the V8 stage of development, the use of the optical sensor grown in the same or in later stages of development is a viable strategy for the nitrogen source at varied doses. Nitrogen fertilization at variable rate based on optical sensor promoted an increase of N uptake by 11.8 % in relation to nitrogen fertilization uniform rate in the third experiment. In all areas investigated, grain yield increased in response to nitrogen fertilization, getting above national average productivities. The use of fertilizer N rate variable strategy despite the slight increase in grain yield of maize was not able to make a statistically significant increase. The efficiency of use of N different indexes evaluated showed improvement with the use of N variable rate based on the optical sensor to the uniform rate. The strategy of N variable rate proved to be efficient as the use of N as measured by a decrease and increase of N rate prescribed by the optical sensor as the nutritional status of the crop, with an effective strategy of the environmental point of view, by reduced risks associated with nitrogen over fertilization. / O milho é o principal cereal produzido no Brasil, sendo altamente responsivo à fertilização nitrogenada, uma vez que os solos tropicais e subtropicais apresentam disponibilidade insuficiente de nitrogênio (N) para atender a demanda da cultura visando à obtenção de elevados rendimentos. Ajustes na dose de N fertilizante podem ser realizados durante o desenvolvimento da cultura através da utilização de sensores de espectrometria ótica. O objetivo deste trabalho foi avaliar a eficiência de fertilização nitrogenada à dose variada, prescrita com uso do N-Sensor® ALS, e correlacioná-la com diferentes atributos vegetativos durante o desenvolvimento da cultura do milho em Latossolos do RS. Foram realizados três experimentos, sendo dois na safra 2008/09 e outro na safra 2010/11. Foram avaliadas a capacidade do sensor em determinar o estado nutricional da cultura e o efeito da aplicação de diferentes doses de N à dose uniforme e dose variada sobre os seguintes atributos vegetativos: teor de N no tecido vegetal, N total absorvido pela parte aérea das plantas, matéria seca e teor relativo de clorofila avaliada pelas leituras com clorofilômetro manual e sobre a produtividade de grãos e eficiência de uso do N. Os atributos vegetativos e produtividade de milho foram amplamente influenciadas pela fertilização nitrogenada e pelas condições climáticas intrínsecas de cada experimento. Durante as fertilizações, o sensor foi capaz de avaliar em média 34 % das plantas na área dos experimentos, com o qual se obteve alta relação das leituras do sensor óptico com a quantidade de N absorvido e matéria seca das plantas de milho apesar de uma perda de eficiência (saturação) observada nos estádios mais tardios de desenvolvimento da cultura. Considerando que o milho absorveu a maior parte do N após o estádio de desenvolvimento V8, a utilização do sensor óptico de plantas neste ou mesmo em estádios posteriores de desenvolvimento é uma estratégia viável para a fertilização nitrogenada a dose variada. A fertilização nitrogenada a dose variada com base no sensor óptico promoveu aumento do N absorvido de 11,8 % em relação à fertilização nitrogenada a dose uniforme no terceiro experimento. Em todas as áreas investigadas, a produtividade de grãos aumentou em resposta à fertilização nitrogenada, obtendo produtividades médias superiores a média nacional. O uso da estratégia de fertilização a dose variada de N apesar do leve incremento na produtividade de grãos de milho não foi capaz de promover o aumento estatisticamente significativo. A eficiência de uso de N avaliada por diferentes índices mostrou uma melhora com o uso da dose variada de N baseada no sensor óptico em relação a dose uniforme. A estratégia de dose variada de N mostrou-se eficiente quanto ao uso do N quando avaliada pela redução e aumento da dose de N prescrita pelo sensor óptico conforme o estado nutricional da cultura, sendo uma estratégia eficiente do ponto de vista ambiental, por reduzir os riscos associados à superfertilização nitrogenada.
|
234 |
Sistema de monitoramento óptico banda larga direto para fabricação de filmes finos multicamadas com sincronização sensorless / Broadband direct optical monitoring system for multilayer thin film manufacturing with sensorless synchronizationAndré Luis Martins 24 March 2011 (has links)
Para a fabricação de filtros ópticos com característica espectral crítica, utiliza-se a tecnologia de filmes finos multicamadas, a qual exige o monitoramento e controle de espessura dos filmes com alta precisão. O sistema tradicional de monitoramento de espessura de filmes, baseado em cristal ressonante, não atende aos requisitos de precisão e repetibilidade do processo exigidos para a fabricação deste tipo de filtro. Já o monitoramento óptico, por sua vez, é um sistema que atende aos requisitos de fabricação destes filtros. Neste trabalho apresenta-se o desenvolvimento de um sistema automático de monitoramento óptico banda larga, para fabricação de filtros com filmes finos multicamadas, que se baseia na utilização de equipamentos ópticos de uso geral disponíveis no mercado. Para realizar análises de desempenho referentes exclusivamente ao algoritmo de automatização, um ambiente de simulação foi preparado, no qual os dados fornecidos pelo equipamento de aquisição de características ópticas durante a deposição efetiva foram substituídos por dados gerados por um algoritmo de simulação de crescimento do filme. Deste modo, o algoritmo de automatização e seus sistemas de segurança puderam ser exercitados. As simulações mostraram que o sistema proposto possui potencial para tornar mais preciso e repetitivo o processo de fabricação de filtros, de modo que atendam aos requisitos das aplicações especiais. / Optical filter manufacturing with critical spectral characteristics uses multilayer thin film technology, which demandas film thickness monitoring and control with high precision. Traditional monitoring systems based on oscillating crystal do not fulfill requirements of accuracy and process repeatability for manufacturing such type of filter. On the other hand, optical broadband monitoring system fulfills the manufacturing requirements to produce these filters. This work presents the development of a broadband optical monitoring system for multilayer thin film filters production, based on general optical equipment commercially available. In order to make the performance analysis related to automation algorithm, a simulation environment has been prepared, where the data supplied by optical data acquisition equipment has been replaced by simulating signals of film growing. Thus the automation algorithm and security systems could be worked. Simulations showed that the system has potential to improve the accuracy and repeatability of the manufacturing process so that the produced filters are able to fulfill the requirements of special applications.
|
235 |
Televisionamento óptico de sondagens - proposta metodológica para execução e suas aplicações em obras subterrâneas / Optical televiewer in boreholes - methodological proposal for implementation and application in underground workDaniela Garroux Gonçalves de Oliveira 06 April 2015 (has links)
A caracterização de um maciço rochoso constitui um passo essencial na geologia de engenharia, proporcionando a possibilidade de previsão do comportamento deste maciço frente às inúmeras solicitações de qualquer obra a ser realizada. No caso de obras subterrâneas urbanas, como linhas metroviárias, por exemplo, a caracterização geológico-geotécnica de maciços rochosos é fundamental para a identificação de condicionantes geológicos associados à sua estabilidade, sendo eficaz na determinação de parâmetros geotécnicos que influenciarão no projeto de escavação desse maciço, seja este através do método convencional (NATM) ou mecanizado, com o uso de tuneladoras (TBM). Feições estruturais como planos de foliação, dobras, falhas e sistemas de fraturas merecem atenção especial por estarem associadas a zonas de fraqueza, além de todas as características geomecânicas do maciço. Em zonas urbanizadas como a Região Metropolitana de São Paulo (RMSP) as condições geológicas, geomorfológicas e de ocupação dificultam a exposição e a identificação destas feições em superfície. Neste contexto foram desenvolvidas novas técnicas para facilitar o acesso às feições supracitadas. Dentre estas se encontra o televisionamento óptico (OPTV, OTV, Optical Televiewer), que consiste na obtenção de imagens 360º das paredes dos furos de sondagem, fornecendo o que pode ser considerado um testemunho virtual de sondagem. O televisionamento óptico é uma tecnologia introduzida no Brasil desde 2001, entretanto apenas recentemente tendo sido introduzido no manual de sondagens da ABGE (2013), contudo não havendo especificações sobre metodologia de aquisição, de interpretação e possibilidades de aplicação. Este trabalho apresenta sugestões para a aquisição destas imagens, sua interpretação e sugestões de aplicações em obras de engenharia, tendo como exemplo a aplicação em projetos de obras subterrâneas do Metrô de São Paulo. No caso específico de escavações subterrâneas urbanas, o conhecimento do subsolo é essencial, já que sua construção é uma atividade a ser desenvolvida dentro do contexto urbano, podendo provocar interferências significativas com a comunidade, implicando em um alto risco à população lindeira. Somado a isto há o fato de que um maciço pouco conhecido poderá implicar em contenções superdimensionadas, aumentando o custo da obra ou subdimensionadas, aumentando o seu risco. Conforme citado em ISRM (1978), à medida que as descrições de maciços rochosos e suas descontinuidades se tornem mais completas e unificadas, será viável projetar estruturas de engenharia em rocha reduzindo os gastos e aumentando a confiabilidade da interpretação e extrapolação dos resultados. / The rock mass characterization is an essential step in engineering geology, providing the possibility of performance prediction of this massive due to numerous requests of any work to be done. In the case of urban underground works, such as subway lines, for example, geological and geotechnical characterization of rock masses is critical for identifying geological conditions linked to its stability, being effective in determining the geotechnical parameters that influence the design of massive excavation, whether by the conventional method (NATM), or mechanized, using tunneling boring machines (TBM). Structural features such as foliation planes, folds, faults and fracture systems deserve special attention as they are associated with weakness zones in addition to all the geomechanical characteristics of the massif. In urbanized areas, such as São Paulo Metropolitan Region (RMSP), geological, geomorphological and occupation hinders exposure and identification of these features on the surface. In this context, new techniques have been developed to facilitate access to the above features. Among these new techniques is the optical televiewer (OPTV, OTV), which is to obtain 360° images of the borehole walls, providing what might be considered a virtual core of a borehole. The optical televiewer has been a technology introduced in Brazil since 2001, but only recently has been published in ABGE 1 Borehole Manual (2013), however, there are no specifications on the acquisition methodology, interpretation and application possibilities. This paper presents suggestions for the acquisition of these images, their interpretation and suggestions of applications in engineering works, taking as an example the design in projects of underground works of the São Paulo Metro. In the specific case of urban underground excavations ground knowledge is essential, since its construction is an activity to be developed within the urban context, which could cause significant interference with the community, resulting in a high risk to neighboring population. Added to this is the fact that a little-known mass can result in oversized contention, increasing the cost of the work or undersized, increasing its risk. As mentioned in ISRM (1978), as the descriptions of rock masses and discontinuities become more complete and unified, it will be feasible to design engineering structures in rock reducing the costs and increasing the reliability of the interpretation and extrapolation of the results.
|
236 |
Expressão do fator de transcrição nuclear kB (NF-kB) em neurônios ocitocinérgicos de ratos submetidos à sobrecarga salina : influência da dexametasona / Expression of nuclear transcription factor kB (NF-kB) in rat ocxytocinergic neurons submitted to salt loading : the influence of dexamethasoneSantos, Patricia Rabelo dos 27 January 2014 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / The hypothalamic-neurohypophysial system is the main system through which the brain maintains homeostasis of bodily fluids. Specifically, the supraoptic (SON) and paraventricular (PVN) hypothalamic nuclei are directly involved with hydroelectrolytic equilibrium and are specialized in the synthesis and secretion of vasopressin and oxytocin (OT). Changes in the milieu intérieur are conceived as stressors by the central nervous system (CNS) and are modulated by the hypothalamic-pituitary-adrenal axis (HPA). Nuclear transcription factor kappa B (NF-κB) mediates immunosuppressant and anti-inflammatory of glucocorticoids. Thus, the aim of this study was to verify the expression profile of component p65 of the NF-κB classical pathway in SON and PVN oxytocinergic neurons in response to dehydration, glucocorticoid treatment, and in normal conditions. Methods: Wistar rats (250-300g) were maintained in controlled environment with temperature (23 ± 2ºC), light/dark cycle of 12 hours and water and food specific for rodents ad labitum until the beginning of experimental period. All procedures were approved by Ethical Comitee of Research with Animals from UFS (Protocol # 60/2012). Animals were grouped into Control (water ad libitum for 4 days, n = 6-7); Control + Dexa (water ad libitum and treated with dexamethasone, n = 6-7); SL4 (salt overloading ad libitum, 1.8% NaCl for 4 days, n = 6-7); SL4 + Dexa (salt overloading ad libitum, 1.8% NaCl for 4 days and dexamethasone, n = 6-7). Dexamethasone (10 mg/kg i.p.) was administered 12 and 2 hours before perfusion and removal of brains for OT/p65 immunofluorescence, or before sacrifice for blood sampling and angiotensin II (ANGII) dosage. We applied two-way ANOVA and Bonferroni posthoc test to analyze behavioral and hormonal dosage data. Results obtained from imunohistochemestry for evaluation of oxytocin and/or p65 neuronal activity, were subjected to qualitative evaluation. We verified SL4 animals ingested more fluid than control, on second (p<0.01), third (p<0.01) and forth (p<0.001) experimental day. SL4 also increased plasmatic concentration of ANGII (p<0.01). Qualitative analysis of double labeling OT/p65 on PVN and SON revealed a weak immunoreactivity for oxytocin on SL4 and SL4 + Dexa groups, when compared to control and Control + Dexa groups. Was observed expression of p65 subunit of NF-κB in all hypothalamic studied areas, with predominant cytoplasmic imunoreactivity in all groups. These data demonstrate that p65 subunit of NF-κB are present in oxytocinergic neurons from the most important hypothalamic areas that integrates the stress axis (HPA) and hidroelectrolyte balance (SHNH). More studies are necessary to clarify the real participation of NF-κB intracellular pathway evoked by intracellular dehydration on endocrines and behavioral hidroelectrolyte adjustments. / O sistema hipotálamo neuro-hipofisário (SHNH) é o principal sistema pelo qual o cérebro mantém a homeostase dos líquidos corporais. Especificamente, os núcleos supra-óptico (SON) e paraventricular (PVN) do hipotálamo estão diretamente envolvidos com o controle do balanço hidroeletrolítico e são especializados na síntese e secreção de vasopressina (AVP) e ocitocina (OT). Alterações no milieu intérieur são vistas como estressoras pelo sistema nervoso central (SNC) e moduladas pelo eixo hipotálamo-hipófise-adrenal (HHA). O fator de transcrição nuclear kappa B (NF-κB) é conhecido por mediar os efeitos imunossupressores e anti-inflamatórios dos glicocorticoides. Sendo assim, o objetivo do presente estudo foi verificar o perfil de expressão do componente p65 da via clássica do NF-κB em neurônios ocitocinérgicos do PVN e SON, em resposta à desidratação crônica, associada, ou não, ao tratamento com glicocorticoides. Métodos: Ratos wistar (250-300 g) foram mantidos em ambiente com temperatura (23 ± 2ºC) e luminosidade, ciclo claro-escuro de 12 horas (luz das 6 às 18 horas), controladas, com água e ração específica para roedores (Labina®- Purina) ad libitum até o início dos experimentos. Todos os procedimentos foram aprovados pelo Comitê de Ética em Pesquisa com Animais da UFS (Protocolo # 60/2012). Os animais foram divididos de modo a constituir os grupos Controle (ratos com acesso à água ad libitum, durante quatro dias, n = 6 - 7); Controle + Dexa (ratos com acesso à água ad libitum, durante quatro dias, e tratados com dexametasona, n = 6 - 7); SL4 (ratos com acesso à sobrecarga salina ad libitum, solução de NaCl 1,8%, durante quatro dias, n = 6 - 7); SL4 + Dexa (ratos com acesso à sobrecarga salina ad libitum, NaCl 1,8%, durante quatro dias e tratados com dexametasona, n = 6 - 7). A dexametasona (10 mg / kg, i.p.) foi administrada apenas no 4º dia, 12h e 2 h antes da perfusão para coleta do cérebro e realização da dupla imunofluorescência OT/p65 ou eutanásia para coleta de sangue do tronco e posterior dosagem de angiotensina II (ANGII). Os dados comportamentais e de dosagem hormonal obtidos foram submetidos ao teste ANOVA de duas vias e pós-teste Bonferroni. Os resultados obtidos da imuno-histoquímica, para a marcação de neurônios expressando ocitocina e/ou p65, foram submetidos à avaliação qualitativa. Verificou-se que os animais SL4 ingeriram mais fluido que seus controles, no segundo (p < 0,01), terceiro (p < 0,001) e quarto (p < 0,001) dia experimental. A SL4 elevou a concentração plasmática de ANGII (p < 0,01). A análise qualitativa da dupla imunofluorescência OT/p65 no PVN e SON revelou uma fraca imunorreatividade à ocitocina nos grupos SL4 e SL4 + Dexa, quando comparados aos grupos Controle e Controle + Dexa. Observou-se expressão da subunidade p65 do NF-κB em todas áreas hipotalâmicas estudadas, com imunorreatividade predominantemente citoplasmática em todos os grupos. Estes dados mostram que a subunidade p65 do NF-κB está presente em neurônios ocitocinérgicos das principais áreas hipotalâmicas que integram os eixos do estresse (HHA) e do equilíbrio hidroeletrolítico (SHNH). Mais estudos são necessários a fim de esclarecer sobre a real participação da via intracelular do NF-κB evocada pela desidratação intracelular, nos ajustes hidroeletrolíticos endócrinos e comportamentais.
|
237 |
Projeto de amplificadores a fibra dopada com érbio para sistemas baseados em multiplexação modal / Erbium doped fiber amplifiers design for modal-division multiplexing systemsAdolfo Fernandes Herbster 11 June 2015 (has links)
Os sistemas ópticos atuais, baseados em fibras monomodo, operam próximos ao limite teórico da capacidade. Sistemas ópticos baseados em multiplexação modal (Mode Division Multiplexing – MDM) possibilitam o aumento da capacidade do sistema por meio do uso de fibras de poucos modos. Nestes sistemas, a propriedade de ortogonalidade entre os modos propagantes permite que cada modo espacial carregue um sinal óptico específico. O amplificador à fibra dopada com érbio (Erbium-Doped Fiber Amplifier – EDFA) segue fundamental para assegurar a transmissão em longas distâncias. No entanto, devido às distintas distribuições de intensidade dos modos que compõem o sinal de entrada, cada modo experimenta diferentes valores de ganho. Desta forma, o objetivo principal no projeto de EDFAs de poucos modos (Few-Mode Erbium-Doped Fiber Amplifier – FM-EDFA) é determinar os melhores parâmetros opto-geométricos da fibra para produzir uma amplificação eficiente. A metodologia normalmente empregada é baseada na resolução das equações de taxa e de propagação. Nesta tese, é proposta uma metodologia alternativa de projeto de FM-EDFA, baseada em uma nova figura de mérito. Este parâmetro quantifica o nível de inversão da população dos íons na fibra a partir da integral de superposição (overlap integral), considerando tanto o perfil de dopagem da fibra dopada com érbio para poucos modos (Few-Mode Erbium-Doped Fiber – FM-EDF) quanto as distribuições de intensidade dos sinais de entrada e de bombeio. A aplicação desta metodologia permite reduzir, em cerca de 25-40 vezes, o número de resoluções das equações de taxa e de propagação e, consequentemente, diminuir o tempo de processamento e reduzir o esforço computacional. Como consequência da maior velocidade de processamento, torna-se possível a aplicação de métodos de otimização mais rigorosos, permitindo uma busca em um espaço irrestrito de soluções. Especificamente, a partir de uma metodologia baseada em algoritmos genéticos, obteve-se um perfil de dopagem otimizado. É também demonstrado que os perfis com geometria circular exibem melhores características, como excelente desempenho do FM-EDFA e maior facilidade de fabricação. Por meio da análise da figura de mérito, é mostrado que o desempenho do FM-EDFA é afetado pelas características do modo de bombeio. Finalmente, o desempenho de um sistema óptico MDM é avaliado, simulado por meio da integração entre as ferramentas MatLab® e VPItransmissionMakerTM, comprovando a necessidade do projeto de um amplificador específico para sistemas MDM. / Modern optical systems based on single-mode fiber, operate close to the theoretical capacity limit. By using few-mode fibers, optical systems based on modal division multiplexing (MDM) allows increased system capacity. In these systems, orthogonality between the propagating modes allows each spatial mode to carry a specific optical signal. The erbium doped fiber amplifier (EDFA) remains essential to ensure long distance transmission. However, due to the distinct intensity profile distributions of the modes which comprise the input signal, each mode experiences a different value of optical gain. Thus, the main objective in the few-mode EDFA design (FM-EDFA) is to determine the best opto-geometrical fiber parameters in order to produce an efficient amplification. The methodology normally used is based on the simultaneous resolution of the rate and propagation equations. In this thesis, we propose an alternative methodology for the FM-EDFA design, based on a new figure of merit which quantifies the level of population inversion for the Er ions in the fiber, by means of a overlap integral considering both the doping profile of the few-mode erbium doped fiber (FM-EDF) as well as the intensity distributions of the optical signals and pump beams. This methodology reduces, by a factor of 25-40, the number of resolutions of the rate and propagation equations, thereby decreasing processing time and computational effort. As a consequence of the improved processing speed, it becomes possible to apply more rigorous optimization methods in an unrestricted solution space. Specifically, by using a genetic algorithm technique, we obtained an optimized doping profile. It is also shown that profiles with circular geometry exhibit improved features, such as excellent FM-EDFA performance and ease of manufacturing. By analyzing the figure of merit, it is shown that the FM-EDFA performance is affected by the characteristics of the pump mode. Finally, the performance of an MDM optical system is evaluated, by integrating Matlab and VPI simulation tools, to demonstrate the need for specific amplifier designs in MDM systems.
|
238 |
Modelagem de diodos laser de Fabry-Pérot travados por injeção de sinal óptico externo para uso em redes WDM-PON. / Modelling of diodes lasers Locked Fabry-Pérot óptical signal injection for use in external networks WDM-PON.Ulysses Rondina Duarte 14 April 2011 (has links)
A disponibilização de fontes ópticas multi-comprimento de onda de baixo custo certamente é um dos aspectos fundamentais para viabilizar a implantação de redes WDMPON (Wavelength Division Multiplexing-Passive Optical Network). Na literatura, são encontradas propostas de algumas tecnologias para a construção de tais dispositivos como a utilização de fontes ópticas sintonizáveis, uso de um vetor de lasers DFB (Distributed Feedback Laser) ou, até mesmo, o fatiamento espectral de uma fonte de banda larga. Contudo, essas propostas apresentam custo elevado, ou limitações de operação, tornando-se inapropriadas para a aplicação de interesse. Uma alternativa que vem sendo amplamente utilizada é o travamento óptico de diodos laser de Fabry-Pérot (FP-LD - Fabry-Pérot laser diode), realizado por meio da injeção de sinal óptico externo provindo do fatiamento espectral de uma fonte de banda larga. O travamento óptico possibilita o controle espectral do FP-LD, e o seu baixo custo torna essa fonte óptica atrativa na implantação de redes WDM. O entendimento do mecanismo de travamento torna-se, então, crucial na descrição da dinâmica de tais fontes ópticas. Desta forma, nesta dissertação, foi desenvolvido o estudo dos modelos matemáticos que descrevem a dinâmica de lasers travados, assim como foi investigado o desempenho de redes WDM-PON empregando estas fontes ópticas. / The availability of low cost multi-wavelength optical sources is certainly one of the fundamental aspects to allow the deployment of WDM-PON networks. Several technologies for the implementation of such optical sources are discussed in the literature, including tunable lasers, DFB arrays and spectral slicing of a broadband light source. However, those propositions suffer from high cost or operational limitations. One alternative is the optical injection locking of a Fabry Pérot laser diode (FPLD), in which the external optical injection signal is obtained from the spectral slicing of a broadband light source. This option has been widely investigated because the optical injection locking process allows for the FP-LD optical spectral control and wavelength selection. In addition, the low cost of such device makes this optical source an attractive solution for WDM-PON widespread deployment. In this context, the understanding of the locking mechanism becomes important in the optimization of such optical sources. Thus, in this dissertation, we conducted a study of mathematical models that describe the dynamics of locked lasers as well as investigated the performance of WDM-PON based on those optical sources.
|
239 |
Estudo das propriedades de armazenamento óptico e grades de relevo em poliuretano derivado de azo-benzeno / Information optically storage and relief gratings study in material derivative of azo-benzene polyrethaneUbaldo Martins das Neves 30 June 2003 (has links)
Polímeros contendo grupos azo-benzênicos têm sido estudados devido a sua capacidade para óptica não linear, formação de superfícies de relevo e de birrefringência fotoinduzida. O fator que possibilita essas aplicações é a propriedade de fotoisomerização reversível trans-cis-trans do grupo azo que produz a sua reorientação molecular. Neste trabalho foram produzidos filmes casting do poliuretano MDI-DR19 derivado de azo-benzeno. Estudou-se o crescimento e decaimento da birrefringência para diferentes valores de potência da luz de excitação da fotoisomerização. Os resultados experimentais do crescimento e decaimento foram analisados usando duas exponenciais e eles mostraram que o polímero MDI-DR19 apresenta boas características para utilização em armazenamento óptico pois cerca de 65% da birrefringência induzida no material permanece por longos intervalos de tempo. Ilustramos o processo de armazenamento de informação gravando uma imagem de birrefringência num filme de MDI-DR19. Foram também produzidas grades de relevo em filmes de MDI-DR19 utilizando franjas de interferência produzidas com luz de polarização P e S. Essas grades apresentaram alta uniformidade e características compatíveis com as mostradas na literatura. / Polymers containing azobenzenic groups have been studied due to their applications on non-linear optics, surface relief gratings (SRG) and photoinduced anisotropy for optical storage. The reversal photoisomerization trans-cis-trans property of the azo group induces a molecular reorientation. In this work, cast films of na azobenzene derivative, the polyurethane MDI-DR19, were studied. The build-up and decay of the birefringence were studied as a function of the photoisomerization exciting light power. The data of the build-up and decay of the birefringence were fitted with a bi-exponential function, which shows the stability of the MDI-DR19 for application in optical storage, since 65% of the induced birefringence remains after a long time. The optical storage is illustrated by recording a birefringence image in a film of MDI-DR19. It was also performed a SRG over films of MDI-DR19 applying an interference finger pattern with a P and S polarized light. The light induced gratings shows good uniformity and characteristics compatible with those presented in the literature.
|
240 |
Desenvolvimento de procedimentos analíticos empregando multicomutação em sistemas de análises em fluxo para determinação fotométrica de vanádio em águas e estanho em alimentos / Development of analytical procedures employing multicommutation flow analysis systems for the photometric determination of vanadium in water and tin in foodsTuanne dos Reis Dias 06 November 2014 (has links)
Esta tese tem como foco o desenvolvimento de procedimentos analíticos automáticos, visando as determinações fotométricas de vanádio e de estanho em águas e em alimentos empregando o processo de multicomutação em fluxo. Um microcontrolador da família PIC e um programa escrito em linguagem Visual Basic 6.0 foram empregados para controle dos dispositivos e aquisição de dados. A unidade de detecção foi construída empregando LED de alto brilho e celas de fluxo com longo caminho óptico (50-200 mm) para ganho em sensibilidade. O módulo de análises, empregando bombas solenoide como propulsores de fluido e o fotômetro foram integrados, formando uma unidade compacta. A determinação de vanádio em águas, mineral e de rio, foi baseada na redução do V(V) à V(IV) com ácido ascórbico e posterior complexação com Eriocromo Cianina R (ECR). Empregando uma cela de 150 mm, o sistema apresentou resposta linear de 0,02 a 1,00 mg L-1, limite de detecção estimado em 13 ?g L-1, coeficiente de variação de 0,87% (n=10) e frequência analítica de 47 determinações por hora. Recuperações entre 89 e 109% foram obtidas para adição de V(V) nas amostras de águas. O procedimento para a determinação de estanho em alimentos foi desenvolvido empregando bomba de multi-seringa como unidade de propulsão de fluidos, cela de fluxo com caminho óptico de 200 mm e parada de fluxo de 50 s. Baseado na reação do Sn(IV) com o violeta de pirocatecol (PCV) na presença de surfactantes, o sistema apresentou resposta linear de 0,10 a 1,25 mg L-1, limite de detecção estimado em 0,04 mg L-1, coeficiente de variação de 1,30% (n=10) e frequência analítica de 49 determinações por hora. Recuperações entre 95 e 115% foram obtidas com a adição de Sn(IV) às amostras de alimentos. / Automatic analytical procedures for photometric determinations of vanadium in water and tin in foods were developed using the multicommutation flow analysis process. A microcontroller of the PIC family and a software written in Visual Basic 6.0 language were used for devices control and data acquisition. Detection unit was designed to use high brightness LED and long optical pathlength flow cells (50-200 mm) to improve sensitivity. The flow analysis module using solenoid mini-pumps as fluid propelling devices and the photometer were integrated in order to form a compact unit. The determination of vanadium in mineral and river waters was based on the reduction of V(V) to V(IV) with ascorbic acid and subsequent complexation with Eriochrome Cyanine R (ECR). Employing flow cell of 150 mm, the system presented linear response between 0.02 and 1.00 mg L-1, detection limit of 13 ?g L-1, variation coefficient of 0.87% (n=10) and sampling throughput of 47 determinations per hour. Recoveries between 89 and 109% were attained for vanadium spiked to mineral and river water. The procedure for determination of tin in foods was development employing a multi-syringe pump as fluid propelling device, a flow cell with optical pathlength of 200 mm and stop flow of 50 s. The procedure was based on the reaction of Sn(IV) with pyrocatechol violet (PCV) in the presence of surfactants, presented linear response between 0.10 and 1.25 mg L-1, detection limit of 0.04 mg L-1, variation coefficient of 1.30% (n=10) and sampling throughput of 49 determination per hour. Recoveries between 95 and 115% were attained for tin spiked samples
|
Page generated in 0.1038 seconds