Spelling suggestions: "subject:"óptica"" "subject:"ópticas""
221 |
Avaliação das camadas internas e externas da retina com tomografia de coerência óptica, eletrorretinograma multifocal e perimetria automatizada padrão em olhos com atrofia em banda do nervo óptico / Evaluation of inner and outer retinal layers with optical coherence tomography, multifocal electroretinography and standard automated perimetry in eyes with band atrophy of the optic nerveRafael Barbosa de Araujo 19 January 2018 (has links)
Objetivos: Comparar as alterações de espessura das camadas da retina macular adquiridas com tomografia de coerência óptica (TCO) e as amplitudes das ondas de eletrorretinograma multifocal (ERGmf) convencional e com estímulo lentificado entre olhos com hemianopsia temporal sequelar por compressão quiasmática e controles saudáveis, além de avaliar as correlações entre TCO, ERGmf e campo visual (CV) central. Métodos: Quarenta e três olhos (30 pacientes) com hemianopsia temporal sequelar por tumores hipofisários previamente submetidos a descompressão quiasmática e 37 olhos saudáveis (19 controles) foram submetidos a TCO-DS da mácula, ERGmf e CV tipo 10-2. Após segmentação, foram medidas as espessuras maculares da camada de fibras nervosas da retina (CFNR), camada de células ganglionares (CCG), camada plexiforme interna (CPI), camada nuclear interna (CNI), camada plexiforme externa (CPE), camada nuclear externa (CNE) e camada de fotorreceptores (CFR). Amplitudes e potenciais oscilatórios (PO) multifocais foram adquiridos com o ERGmf convencional e com estímulo lentificado, respectivamente, analisados em valores médios por quadrantes e hemicampos. Resultados: Espessuras da CFNR, CCG e CPI foram significantemente menores em todos os quadrantes, enquanto CNI, CPE e CFR tiveram medidas significantemente maiores nos quadrantes nasais nos pacientes comparados com os controles. Correlações significantes entre a TCO e os valores de CV 10-2 foram positivas para CFNR, CCG e CPI, e negativas para CNI, CPE e CFR. As amplitudes médias dos POs e de N1 do ERGmf se mostraram significantemente reduzidas na hemirretina nasal dos pacientes. Correlações significantes foram encontradas entre as amplitudes de PO e ERGmf para com medidas de TCO da hemirretina nasal interna e externa, respectivamente. Conclusões: Pacientes com hemianopsia temporal sequelar por compressão quiasmática previamente tratada apresentam adelgaçamento significante de CFNR, CCG e CPI e espessamento de CNI, CPE e CFR, associados com amplitudes reduzidas de PO e N1, sugerindo que o dano axonal à retina interna desencadeia lesão secundária das camadas externas da retina nesta condição / Purpose: To compare optical coherence tomography (OCT)-measured macular retinal layers in eyes with permanent temporal hemianopia from chiasmal compression and controls, compare regular and slow-flash multifocal electroretinography (mfERG) in patients and controls, and assess the correlation between OCT, mfERG and central visual field (VF) data. Methods: Forty-three eyes (30 patients) with permanent temporal hemianopia from pituitary tumors previously submitted to chiasm decompression and 37 healthy eyes (19 controls) were submitted to macular SD-OCT, mfERG and 10-2 VF testing. After segmentation, macular retinal nerve fiber layer (RNFL), ganglion cell layer (GCL), inner plexiform layer (IPL), inner nuclear layer (INL), outer plexiform layer (OPL), outer nuclear layer (ONL) and photoreceptor layer plus (PRL+) thickness was measured. Amplitudes and oscillatory potentials (OP) were measured on regular and slow-flash mfERG, respectively, and expressed as mean values per quadrant and hemifield. Results: RNFL, GCL and IPL thickness measurements were significantly reduced in all quadrants while INL, OPL and PRL were significantly increased in the nasal quadrants in patients compared to controls. Significant correlations between OCT and 10-2 SAP measurements were positive for RNFL, GCL and IPL and negative for INL, OPL and PRL. OPs and mfERG N1 amplitudes were significantly reduced in the nasal hemiretina of patients. Significant correlations were found between OP and mfERG amplitudes for inner and outer nasal hemiretina OCT measurements, respectively. Conclusions: Patients with permanent temporal hemianopia from previously treated chiasmal compression displayed significant RNFL, GCL, IPL thinning and INL, OPL and PRL thickening associated with reduced OP and mfERG N1 amplitudes, suggesting axonal injury to the inner retina leads to secondary damage to the outer retina in this condition
|
222 |
Eletrorretinograma de padrão reverso (PERG) de campo total na esclerose múltipla e na neuromielite óptica e PERG multifocal na atrofia em banda do nervo óptico: correlação com os achados da tomografia de coerência óptica e da perimetria c / Pattern-reversal electroretinogram (PERG) full field in multiple sclerosis and optic neuromyelitis and multifocal PERG in band atrophy of the optic nerve: correlation with the findings of optical coherence tomography and computerized perimetryKenzo Hokazono 25 April 2014 (has links)
OBJETIVO: avaliar a capacidade do eletrorretinograma de padrão reverso de campo total (PERG) e multifocal (PERGmf) de detectar alterações funcionais da retina em pacientes com afecções desmielinizantes e compressivas da via óptica anterior; estudar a correlação entre as amplitudes do PERG e PERGmf com as espessuras das camadas internas da retina obtidas pela tomografia de coerência óptica (TCO) e com a perda de campo visual avaliada pela perimetria computadorizada padrão (PCP). MÉTODOS: cento e cinquenta e dois olhos de 28 pacientes com esclerose múltipla (EM), 38 com espectro da neuromielite óptica (NMO) com ou sem neurite óptica (NO) prévia e 30 olhos de 26 controles normais foram submetidos ao PERG, à TCO para avaliação da camada de fibras nervosas da retina (CFNR) peripapilar e camadas internas da retina na mácula e à PCP. Os olhos estudados foram divididos em 4 grupos: grupo 1. EM com NO; grupo 2. EM sem NO; grupo 3. NMO; grupo 4. Mielite transversa longitudinal extensa. Os achados foram comparados utilizando-se as equações de estimativas generalizadas. As correlações entre os achados do PERG, da TCO e da PCP foram avaliadas pela correlação de Pearson ou Spearman e pela análise de regressão linear. Para avaliação dos pacientes com doenças compressivas da via óptica anterior, foram estudados 25 olhos de pacientes com defeito campimétrico temporal e atrofia em banda (AB) do nervo óptico decorrente de compressões quiasmáticas já tratadas e 25 olhos de 25 controles normais pelo PERGmf, a TCO e a PCP. As comparações entre olhos com AB e controles foram feitas usando análise de variância (ANOVA). As correlações entre achados do PERGmf, da TCO e da PCP foram avaliadas pela correlação de Pearson ou Spearman e pela análise de regressão linear. RESULTADOS: comparado com controles, as amplitudes do PERG foram significativamente reduzidas em olhos de pacientes com NMO e EM com NO, mas não mostraram diferenças significativas em olhos de pacientes com EM sem NO e mielite transversa longitudinal extensa. Correlações significantes foram encontradas entre os valores de amplitude de N95, a espessura da camada de células ganglionares da retina e a espessura da CFNR peripapilar. As reduções de amplitudes do PERG também foram significativamente associadas à perda de sensibilidade do campo visual. Na avaliação de pacientes com AB do nervo óptico, as amplitudes do PERGmf foram significativamente reduzidas nos quadrantes temporais quando comparados com controles. Não houve diferenças de amplitude nos setores nasais. Correlações significativas foram encontradas entre as amplitudes do PERGmf, a espessura macular total e a CFNR peripapilar no setor temporal e a perda de sensibilidade do campo visual. CONCLUSÕES: O PERG foi capaz de detectar perda funcional em pacientes com EM e NMO com NO prévia e suas amplitudes foram significativamente correlacionadas com a espessura das camadas internas da retina e camada de fibras nervosas peripapilar. As amplitudes do PERGmf foram capazes de demonstrar perda funcional em pacientes com AB do nervo óptico e apresentaram correlações significantes com a perda de sensibilidade do campo visual e as medidas de espessura macular total e da CFNR peripapilar / PURPOSE: To evaluate the ability of full-field and multifocal (mf) pattern electroretinogram (PERG) parameters to detect functional changes of the retina in patients with demyelinating and compressive diseases of the anterior visual pathway; to study the relationship between the PERG (full field and multifocal) amplitudes, optical coherence tomography (OCT)-measured inner retinal layers measurements and visual field sensitivity loss on standard automated perimetry (SAP). METHODS: one hundred fifty-two eyes of 28 patients with multiple sclerosis (MS), 38 with neuromyelitis optica (NMO) spectrum with or without previous episodes of optic neuritis (ON) and 30 eyes of 26 normal controls underwent PERG, OCT macular and peripapillary retinal nerve fiber layer measurements and SAP. The eyes of the patients were divided into 4 groups: group 1. EM with ON; group 2. EM without ON; group 3. NMO; group 4. Longitudinally extensive transverse myelitis (LETM). The findings were compared using the generalized estimating equations (GEE). The correlations between the findings of the PERG, OCT and SAP were assessed by Pearson correlation coefficients or Spearman\'s rank correlation coefficients and linear regression analysis. For evaluation of patients with compressive diseases of the anterior visual pathway, 25 eyes of patients with temporal visual field defect and band atrophy (BA) of the optic nerve due to chiasmal compression and 25 eyes of 25 normal controls were studied by mfPERG, OCT and SAP. Comparisons between BA and control eyes were made using variance analysis (ANOVA). The correlations between the findings mfPERG, OCT and SAP were evaluated by Pearson correlation coefficients or Spearman\'s rank correlation coefficients and linear regression analysis. RESULTS: compared to controls, PERG amplitudes were significantly reduced in eyes of patients with MS with ON and NMO, but not in eyes with MS without ON and longitudinal extensive transverse myelitis. Significant correlations were found between N95 amplitudes values, OCT-measured macular ganglion cell layer thickness, total retinal thickness, and temporal peripapillary RNFL thickness.The reduced mfPERG amplitudes were also significantly associated with loss of visual field sensitivity. In the evaluation of patients with BA of the optic nerve, mfPERG amplitudes were significantly reduced in the temporal quadrants when compared with controls. There were no differences in the amplitudes values in the nasal sectors. Significant correlations were found between mfPERG amplitudes, OCT-measured total macular thickness and peripapillary RNFL in the temporal sector and the loss of sensitivity of the visual field. CONCLUSIONS: full-field PERG measurements were able to detect functional loss in patients with MS and NMO with previous episodes of ON and PERG amplitudes were significantly correlated with inner retinal layers thicknesses and peripapillary RNFL. Multifocal PERG amplitudes were able to demonstrate functional loss in patients with BA of the optic nerve and showed significant correlations with visual field sensitivity loss and OCT-measured total macular and peripapillary RNFL thickness
|
223 |
Chaves ópticas compactas baseadas em ressoador magneto-óptico em cristal fotônico bidimensionalZIMMER, Daimam Darlam 08 August 2014 (has links)
Submitted by Hellen Luz (hellencrisluz@gmail.com) on 2017-10-03T14:15:24Z
No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_ChavesOpticasCompactas.pdf: 14902318 bytes, checksum: 61976802fa05c3cb71a63848b89f2859 (MD5) / Rejected by Edisangela Bastos (edisangela@ufpa.br), reason: on 2017-10-10T17:03:15Z (GMT) / Submitted by Hellen Luz (hellencrisluz@gmail.com) on 2017-10-16T14:19:18Z
No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_ChavesOpticasCompactas.pdf: 14902318 bytes, checksum: 61976802fa05c3cb71a63848b89f2859 (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-11-13T15:58:01Z (GMT) No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_ChavesOpticasCompactas.pdf: 14902318 bytes, checksum: 61976802fa05c3cb71a63848b89f2859 (MD5) / Made available in DSpace on 2017-11-13T15:58:01Z (GMT). No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_ChavesOpticasCompactas.pdf: 14902318 bytes, checksum: 61976802fa05c3cb71a63848b89f2859 (MD5)
Previous issue date: 2014-08-08 / CNPq - Conselho Nacional de Desenvolvimento Científico e Tecnológico / No presente trabalho, investigou-se três possibilidades de chaves ópticas (switches), baseadas em cristal fotônico, sendo duas destas construídas a partir de um material magnetoóptico, projetadas para operar na faixa de frequência óptica e a última por cilindros dielétricos, projetada para operar na faixa de frequência de terahertz, ambas constituídas de dois guias de onda acoplados a cavidade ressonante. As chaves ópticas constituídas de material magneto-óptico têm suas cavidades formadas por furos cilíndricos dispostos de forma a montar anéis concêntricos ao redor de um furo central, sendo a primeira com acoplados frontal dos guias de onda formado um ângulo de 180o entre si e alinhadas com a cavidade ressonante. A segunda, com acoplados lateral dos guias de onda a cavidade ressonante. São inseridos no material magneto-óptico bidimensional defeitos (furos formando uma rede triangular). A chave óptica, construída por cilindros dielétricos dispostos de forma a montar uma rede quadrada, tem sua cavidade constituída de um cilindro de Níquel-Zinco-Ferrite, e seus guias de onda formam um ângulo de 90o. Os dispositivos possuem dois estados, um estado onde há transmissão de sinal (estado on) e um estado onde ocorre o bloqueio do sinal (estado off ), sendo a transição entre os mesmos controlada a partir da variação de um campo magnético DC externo H0. O funcionamento dos dispositivos é baseado na orientação de um modo de dipolo, excitado na cavidade ressonante por um sinal eletromagnético, que entra por uma das portas do dispositivo. Para as duas chaves construídas de material magneto óptico, o estado on é obtido sem magnetização. Nesta situação, os nós do dipolo alinham-se de modo perpendicular ao eixo dos guias de onda, ocorrendo assim a transmissão de sinal, com baixas perdas de inserção, enquanto que no estado off com campo magnético externo diferente de zero, para o dispositivo com acoplamento frontal o modo dipolo sofre uma rotação por 90º e para o dispositivo com acoplamento lateral o modo dipolo apresenta uma rotação no sentido anti-horário interrompendo a transmissão do sinal, com alta isolação. Para a chave construída de cilindros dielétricos, o estado on é obtido com magnetização e o modo dipolo apresenta uma rotação no sentido horário transmitindo o sinal, enquanto que no estado off, sem campo magnético externo, o modo dipolo é estacionário, com os nós do modo dipolo alinhados com os guias de onda interrompendo a transmissão do sinal. / In the present work, investigated three possibilities of optical key (switch) based on Photonic Crystal, two of these being constructed from a magneto-optic material, designed to operate in the optical frequency range and the last cylinder of dielectric, designed to operate in the terahertz frequency range, both consist of two coupled waveguides resonant cavity. The optical keys consist of material magneto optical, has a cavity formed by cylindrical holes disposed so as to mount concentric rings around a central hole, and the first, with front of coupled waveguides formed a angles of 180o aligned with each other and the resonant cavity. The second side coupled to the waveguide resonant cavity. Are inserted into the magneto-optical material in two- dimensional photonic crystal defects (holes forming a triangular lattice). The optical key constructed by dielectric cylinders arranged in order to mount a square lattice, has a hollow cylinder composed of a nickel-zinc-ferrite, and their wave guides are at an angle of 90o. The devices has two states, a state where there is transmission signal (state on) and a state where the lock signal occurs (state off ), being the transition between them controlled from the variation of an external DC magnetic field H0. The operation of the device is based on the orientation of a dipole mode, excited resonant cavity for electromagnetic signal. In state on no magnetisation dipole nodes align perpendicular to the axis of the waveguides, occurring so the signal transmission, with low insertion losses, While in the State off non-zero external magnetic field the dipole mode is rotated by 90o for coupling the front and to the device with lateral coupling the dipole mode shows a rotation in counterclockwise interrupting signal transmission, with high isolation. For the key cylinder constructed of dielectric, the condition on magnetization is obtained, the dipole mode shows a clockwise rotation transmitting the signal, whereas in state off without external magnetic field, the dipole mode is stationary, with the nodes of the dipole mode aligned with the waveguides stopping the signal transmission.
|
224 |
Caracterização e desenvolvimento de sensores ópticos de corrente elétrica para aplicações em linhas de alta tensãoSANTA BRÍGIDA, Angela Costa 03 April 2017 (has links)
Submitted by Hellen Luz (hellencrisluz@gmail.com) on 2017-07-03T18:44:46Z
No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Tese_CaracterizacaoDesenvolvimentoSensores.pdf: 4867708 bytes, checksum: 9c430ec1e788fb2f788ed5f2dee7409f (MD5) / Approved for entry into archive by Irvana Coutinho (irvana@ufpa.br) on 2017-08-09T14:38:21Z (GMT) No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Tese_CaracterizacaoDesenvolvimentoSensores.pdf: 4867708 bytes, checksum: 9c430ec1e788fb2f788ed5f2dee7409f (MD5) / Made available in DSpace on 2017-08-09T14:38:21Z (GMT). No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Tese_CaracterizacaoDesenvolvimentoSensores.pdf: 4867708 bytes, checksum: 9c430ec1e788fb2f788ed5f2dee7409f (MD5)
Previous issue date: 2017-04-03 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / CNPq - Conselho Nacional de Desenvolvimento Científico e Tecnológico / Esta tese, intitulada “Caracterização e desenvolvimento de sensores ópticos de corrente elétrica para aplicações em linhas de alta tensão” foi desenvolvida no âmbito de um programa de doutorado em Engenharia Elétrica. Foram implementados e caracterizados sensores de corrente magneto-óptico, para aplicações de medição e proteção em sistemas de alta potência, nomeadamente, prisma sensor e sensor com fibra de cristal fotônico (PCF). Ambos, são baseados no efeito Faraday, utilizando uma configuração polarimétrica em dupla quadratura. Este trabalho foi, então, dividido, em dois momentos. No primeiro, um prisma sensor, constituído de uma cabeça sensora portátil para ancoragem na linha de transmissão foi desenvolvido, em Portugal, para uma aplicação industrial. Neste caso, no protótipo do prisma sensor foi utilizado um prisma de vidro Schott SF57 de 8cm de comprimento com alta constante de Verdet e baixa birrefringência. Ele foi incorporado em um invólucro de Nylon adequado para aplicações de fixação na linha de alimentação. A operação do sensor é caracterizada e comparada usando Diodos Super Luminescentes (SLD) distintos como fontes ópticas, com emissão a 650, 830 e 1550 nm. O sensor demonstrou precisão de classe 1, para correntes nominais iguais ou superiores a 900 ARMS e classes 0,1 e 0,2 para correntes nominais de 1,2 kARMS e 0,3 kARMS, respectivamente, e a possibilidade de detectar impulsos na rede abaixo dos 10 μs. Em um segundo momento, outra configuração envolveu o uso de fibras ópticas como elemento transdutor, empregando, fibras torcidas altamente birrefringente com 4,5, 6, 9, e 11 rotações por segundo, desenvolvidas pelo grupo do Laboratório de Fibras Especiais & Materiais Fotônico – LaFE, do Instituto de Física Gleb Wataghin da UNICAMP, no Brasil. Em particular, estas fibras foram testadas enrolando-as em torno de um condutor elétrico utilizando três tamanhos de enrolamento de 6, 12 e 18 cm de diâmetros com diferentes voltas, com correntes de até 800 ARMS usando uma fonte SLD a 650 nm. Parâmetros, tais como a sensibilidade e a linearidade do sensor, foram investigados. Uma simulação também foi realizada para analisar quantitavamente o valor da sensibilidade das fibras com relação ao número de voltas e com relação ao diâmetro do suporte, no qual foi concluído que deve haver um compromisso entre estes dois parâmetros afim de obter uma melhor resposta no sinal de saída do sensor. / This thesis, titled "Characterization and development of electric sensors for electrical applications in high voltage lines" was developed in a PhD program in Electrical Engineering. Fix the devices and characterized the magneto-optical current sensors for measurement applications and protection in high power systems, namely, prism sensor and photonic glass fiber (PCF) sensor. Both are based on the Faraday effect, using a double quadrature polarimetric configuration. This work was then divided in two moments. In the first, a prism sensor, consisting of a portable sensor head for anchoring in the transmission line was developed, in Portugal, for an industrial application. In this case, no prism sensor prototype was used in a Schott SF57 glass prism 8cm in length with high Verdet constant and low birefringence. It has been incorporated into a Nylon casing suitable for fastening applications in the power line. The operation of the sensor is characterized and compared using Super Luminescent Diodes (SLD) as a source of 650, 830 and 1550 nm. Class 1 precision sensor for nominal currents of 900 ARMS or higher and classes 0,1 and 0,2 for nominal currents of 1,2 kARMS and 0,3 kARMS, respectively, and the possibility of detecting impulses in the network of 10 Μs. Second, another type of wrapping, the use of optical fibers as a transition element, using highly rotated fibers at 4, 6, 9, and 11 revolutions per second, developed by the group of the Laboratory of Special Fibers and Photonic Materials - LaFE, from the Institute of Physics Gleb Wataghin of UNICAMP, Brazil. In particular, these lines were tested as a whole on an electric conductor using three winding sizes of 6, 12 and 18 cm in diameters with different turns, with currents of up to 800 ARMS using an SLD source at 650 nm. Parameters, such as sensitivity and linearity of the sensor, were investigated. A symbolic analysis was also performed to quantitatively analyze the fiber sensitivity value with respect to the number of turns and with respect to the diameter of the support, there is no conclusion that there is a compromise between these two parameters in order to obtain a better response in the signal of sensor output.
|
225 |
Controle dos efeitos da mistura de quatro ondas (FWM) para melhoria no gerenciamento do QoS óptico em redes GMPLS/DWDM. / Control of the four wave mixing (FWM) effects for improvement in the optical QOS management in GMPLS /DWDM networks.Lopes, Carlos Magno Baptista 29 March 2011 (has links)
Este trabalho investiga a influência dos efeitos da mistura de quatro ondas (FWM -. Four- Wave Mixing) durante o estabelecimento de caminhos ópticos em uma rede GMPLS/DWDM (Generalized MultiProtocol Label Switching/Dense Wavelength Division Multiplexing). Para minimizar seus impactos e assim reduzir o bloqueio total da rede, são propostas estratégias por meio de extensões ao RSVP-TE (Resource Reservation Protocol-Traffic Engineering). A partir de uma plataforma de simulação que emula e integra a camada óptica e o Plano de Controle da arquitetura GMPLS, a solução proposta é validada. Os vários métodos de alocação de comprimentos de onda são avaliados e as contribuições na redução dos sinais interferentes quantificadas. Para minimizar o bloqueio na rede, uma nova classe de métodos de alocação, classificados como híbridos, é definida e seu desempenho é avaliado. O bloqueio da rede em função da variação de parâmetros que reforçam a eficiência da FWM, tais como a quantidade e espaçamento entre canais, é observado, confirmando a necessidade de métodos de alocação especialistas para gerenciamento do QoS (Quality of Service) óptico em cada caminho a ser estabelecido. Os resultados obtidos comprovam a eficiência da solução proposta e evidenciam a necessidade de um Plano de Controle GMPLS com acurada visibilidade das restrições da camada física, tanto os efeitos estáticos quanto às degradações associadas ao comportamento dinâmico da rede. / This work investigates the effects of the Four-Wave Mixing (FWM) during the lightpaths establishment in a GMPLS/DWDM (Generalized Multiprotocol Label Switching / Dense Wavelength Division Multiplexing) network. In order to minimize their impacts and thus reduce network blocking, strategies based on RSVP-TE (Resource Reservation Protocol- Traffic Engineering) extensions are proposed. The proposed solution is validated using a simulation platform that integrates and emulates the optical layer and the GMPLS Control Plane. The various wavelength allocation methods are evaluated and their contributions on the reduction of interfering signals are quantified. In order to minimize the network blocking, a new class of allocation methods (classified as hybrids) is defined and its performance is evaluated. The network blocking caused by the parameters that enhance the FWM efficiency, such as the number and spacing between channels, is also observed, confirming the need of specialized wavelength allocation methods for managing the optical QoS for each lightpath. The results obtained ascertain that the proposed solution is efficient and demonstrate the need for a GMPLS Control Plane endowed with an accurate visibility of the restrictions in the physical layer, concerning both static and dynamic effects.
|
226 |
Efecto de la hipertensión ocular en la población de células ganglionares de la retina de rata y ratónSalinas Navarro, Manuel Ángel 11 March 2011 (has links)
En esta tesis estudiamos la población total de las células ganglionares de la retina (CGR) en rata y ratón, y desarrollamos un modelo experimental de hipertensión ocular mediante fotocoagulación láser. La población de CGR proyecta masivamente a los colículos superiores. Se observa una estría visual en la retina dorsal donde se encuentra las densidades más altas de CGR. La pequeña población de CGR ipsilateral se distribuye mayoritariamente en la periferia de la retina temporal.
El aumento de la presión intraocular induce una compresión de los axones en la cabeza del nervio óptico que provoca una alteración del transporte axonal retrógrado, que induce una degeneración sectorial localizada y difusa de las CGR, preferentemente en la retina dorsal, así como de sus axones. La pérdida selectiva de las CGR en la capa de CGR, sugiere que la causa de la muerte de las CGR no se debe a una isquemia retiniana. / In this thesis we have studied the total population of retinal ganglion cells (RGCs) in rat and mouse, and developed an experimental model of ocular hypertension by laser photocoagulation. The RGC population projects massively to the superior colliculi. There is a visual streak in the dorsal retina where the highest densities of RGCs are found. The small population of ipsilateral RGCs is distributed mainly in the periphery of the temporal retina.
The increase of intraocular pressure induces a compression of the axons at the optic nerve head that causes a disturbed retrograde axonal transport, inducing a localized, diffuse and sectorial degeneration of RGCs and their axons, preferably in the dorsal retina. The selective loss of RGCs in the RGC layer, suggests that the cause of the RGC loss is not due to retinal ischemia.
|
227 |
Análise de fibras ópticas baseadas em quase cristais fotônicosCâmara, João Maria 07 November 2014 (has links)
Submitted by Lara Oliveira (lara@ufersa.edu.br) on 2017-07-13T22:58:20Z
No. of bitstreams: 1
JoãoMC_DISSERT.pdf: 1741418 bytes, checksum: 13c15c64738df641ff1a1cadad54fa09 (MD5) / Approved for entry into archive by Vanessa Christiane (referencia@ufersa.edu.br) on 2017-07-18T15:08:39Z (GMT) No. of bitstreams: 1
JoãoMC_DISSERT.pdf: 1741418 bytes, checksum: 13c15c64738df641ff1a1cadad54fa09 (MD5) / Approved for entry into archive by Vanessa Christiane (referencia@ufersa.edu.br) on 2017-07-18T15:09:03Z (GMT) No. of bitstreams: 1
JoãoMC_DISSERT.pdf: 1741418 bytes, checksum: 13c15c64738df641ff1a1cadad54fa09 (MD5) / Made available in DSpace on 2017-07-18T15:10:18Z (GMT). No. of bitstreams: 1
JoãoMC_DISSERT.pdf: 1741418 bytes, checksum: 13c15c64738df641ff1a1cadad54fa09 (MD5)
Previous issue date: 2014-11-07 / In this work, it is analyzed two applications involving optical fiber. In the first application, a new design of an optical fiber coupler composed by two and three cores from a fiber with step index is proposed and analyzed using a vector formulation based on finite element applied in conjunction with genetic algorithm (GA). The fiber is made with pure silica and silica doped with germanium and it is composed by two and three identical cores separated by distance d. The proposed structure has a very simple geometry, and each fiber that composed the coupler is obtained by inclusion of a very small air hole at the core of each conventional step index fibers. Next, optical fiber composed by photonic quasi-crystals, through a quasi-periodic and symmetric matrix, is analyzed using the finite element method, applied in conjunction with perfectly matched layers of type cylindrical. The structure is composed of germanium-doped silica and it is originates from twelve distributions of air holes arranged symmetrically with a defect caused by the absence of central air hole / Neste trabalho, serão analizadas duas aplicações envolvendo fibra óptica. Na primeira aplicação um novo projeto de um acoplador de fibra óptica constituída por dois e três núcleos a partir de uma fibra com índice degrau é proposta e analisada através de uma formulação vetorial baseada em elementos finitos aplicada em conjunto com o Algoritmo Genético (GA).A fibra é feita desílica pura e sílica dopada com germânio e contém dois e três núcleos idênticosseparados por umadistância d. A estrutura proposta apresenta uma geometria bastante simples, ecada fibra que compõe o acoplador é obtida através da inclusão de um buraco de ar muito pequeno no núcleo de cada uma das fibras de índice degrau convencional. Na segunda aplicação, fibras ópticas constituídas por quase cristais fotônicos, através de uma matriz quase periódica e simétrica é analisada através do método dos elementos finitos, aplicado em conjunto com camadas perfeitamente casadas do tipo cilíndricas. A estrutura é composta por sílica dopada com germânio e é originada a partir de doze distribuições de buracos de ar organizados simetricamente com um defeito provocado pela ausência do buraco de ar central / 2017-07-13
|
228 |
Estratégias analíticas para determinação de urânio em amostras de águas e efluentes industriaisSantos, Juracir Silva 16 April 2013 (has links)
Submitted by Ana Hilda Fonseca (anahilda@ufba.br) on 2013-04-03T14:38:28Z
No. of bitstreams: 2
Juracir Santos 2011-212 SLCF.docx: 14953 bytes, checksum: ecc1d6899f344c253ec324748e3c4cc7 (MD5)
Tese - Juracir Silva Santos.pdf: 2944425 bytes, checksum: 25ce15e90c56cd72422b47a715f94a0f (MD5) / Rejected by Ana Hilda Fonseca(anahilda@ufba.br), reason: Retirar arquivo em doc on 2013-04-16T16:32:47Z (GMT) / Submitted by Ana Hilda Fonseca (anahilda@ufba.br) on 2013-04-16T16:38:31Z
No. of bitstreams: 1
Tese - Juracir Silva Santos.pdf: 2944425 bytes, checksum: 25ce15e90c56cd72422b47a715f94a0f (MD5) / Approved for entry into archive by Ana Hilda Fonseca(anahilda@ufba.br) on 2013-04-16T16:39:25Z (GMT) No. of bitstreams: 1
Tese - Juracir Silva Santos.pdf: 2944425 bytes, checksum: 25ce15e90c56cd72422b47a715f94a0f (MD5) / Made available in DSpace on 2013-04-16T16:39:26Z (GMT). No. of bitstreams: 1
Tese - Juracir Silva Santos.pdf: 2944425 bytes, checksum: 25ce15e90c56cd72422b47a715f94a0f (MD5) / CAPES / O trabalho foi desenvolvido no âmbito do projeto 993/2007 – “Desenvolvimento de estratégias analíticas para a determinação de urânio em amostras ambientais e industriais – Monitoramento ambiental da cidade de Caetité, Bahia” e viabilizado através de uma parceria firmada entre a Universidade Federal da Bahia e a Comissão Nacional de Energia Nuclear. Neste trabalho foram desenvolvidas estratégias para a determinação de urânio em amostras de águas naturais e efluentes provenientes de mina de urânio. Uma avaliação crítica da determinação de urânio por espectrometria de emissão óptica com plasma indutivamente acoplado (ICP OES) foi realizada usando planejamentos fatoriais e Doehlert envolvendo as variáveis: concentração de ácido, potência de radiofrequência e vazão do gás de nebulização. Simultaneamente, cinco linhas de emissão foram estudadas (367,007; 385,464; 385,957; 386,592 e 409,013 nm), na presença de HNO3, H3C2OOH ou HCl. As determinações empregando o HNO3 foram as mais sensíveis. Entre as variáveis estudadas, a vazão do gás de nebulização foi a mais significativa, para as cinco linhas de emissão. A presença de cálcio causou interferência na intensidade de emissão de algumas linhas e ferro não interferiu (pelo menos até 10 mg L−1) nas cinco linhas estudadas. A presença de outros 13 elementos foi avaliada simultaneamente e, não afetou a intensidade de emissão. Sob condições otimizadas, usando a linha 385,957 nm, o método permite a determinação de urânio com limite de quantificação de 30 μg L−1 e precisão, expressa como RSD, menor que 2,2% para as concentrações de urânio de 500 e 1000 μg L−1. Na segunda estratégia, um procedimento em fluxo, com alta sensibilidade foi proposto para a determinação de urânio em amostras de água. Uma cela de caminho óptico de 100 cm baseada em guia de onda com núcleo líquido (LCW) foi usada para aumentar a sensibilidade do método do arsenazo III e possibilitar a detecção de urânio para atender aos limites estabelecidos pela legislação ambiental vigente. O sistema de fluxo foi desenvolvido com microbombas solenoide, a fim de melhorar a mistura e minimizar o consumo de reagente, bem como a geração de resíduos. A resposta linear do método observada foi 5,0-150,0 µg L-1, com limite de detecção, RSD e frequência de amostragem estimados em 1,3 µg L-1 (99,7% de confiança), 0,7% (n = 20) e 40 determinações por hora, respectivamente. O consumo de arsenazo III foi reduzido em 1250 vezes em comparação com um procedimento de pré-concentração em fase sólida. A exatidão dos métodos foi confirmada pela análise de dois materiais de referência de laboratório fornecido pela CNEN. Além disso, uma amostra de efluente foi analisada por espectrometria de massas com plasma indutivamente acoplado (ICP-MS) e as recuperações foram satisfatórias. Os métodos desenvolvidos foram aplicados na determinação de urânio em água potável, de rio e de poço, e efluentes industriais provenientes das minas de extração de urânio da cidade de Caetité. Os resultados encontrados para urânio em amostras de água potável de Caetité estavam abaixo do limite de quantificação dos métodos, exceto para uma amostra de água de poço subterrâneo (17,0 ± 0,8 µg L-1) e uma amostra de água de rio coletada nas imediações da mina (9,6 ± 0,8 µg L-1). / Salvador
|
229 |
Efeitos da adição de fulereno nas propriedades ópticas, térmicas e eletrônicas de cristais líquidos esméticos / Effects of fullerene addition on the optics, termic and electronics properties of smectic liquid crystalsSilva, Lidiane Maria Omena da 30 May 2014 (has links)
The study of optical, thermal and electronic properties of liquid-crystalline systems has attractedd an enormous interest of the scientific community, due to the potencial applicability of such systems in eletroc-optical devices. In this work, the effects of C60 fullerene addition on the physico-chemical properties of liquid crystals are investigated. By using different experimental techniques, it was possible do determine how the addition of a non-mesogenic and electron donor compound affects important physical parameters, such as the thermal diffusivity and the non-linear refractive index. From time-resolved Z-scan measurements, the thermo-opitical properties of the fullerene-doped and pure liquid crystal samples are investigated.Our results show that the insertion of fullerene reduces the nematics-smectic-A transition temperature, as well as affects the heat diffusion mechanisms in nematic and smectic phases. Concerning the non-linear optical properties, it is observed that the optical Freedericskz transition presents a continuous nature in the nematic phase, with the number of self-modulation rings increasing as the excitationa intensity is enhanced above the Freedericskz threshold. Further, it is observed that the addition of fullerene increases the non-linear optical reponse of the system. Using the two-beam coupling technique and photoconductivity measurements in the steady-state regime, the transport and photorefractive properties of doped sample are also analyzed. / Conselho Nacional de Desenvolvimento Científico e Tecnológico / O estudo de propriedades ópticas, térmicas e eletrônicas de sistemas líquido-cristalinos tem atraído enorme interesse da comunidade científica, por conta do grande potencial de aplicação destes sistemas em dispositivos eletro-ópticos. Neste trabalho, são investigados os efeitos da adição de fulereno C60 sobre as propriedades físico-químicas de cristais líquidos. Usando diferentes técnicas experimentais, foi possível determinar como a adição de um agente não-mesogênico e doador de elétrons afeta parâmetros físicos importantes, tais com a difusividade térmica e o índice de refração não-linerar. A partir de medidas de varredura Z resolvida no tempo, as propriedades termo-ópticas das amostras de cristal líquido puro e dopado com fulereno são investigadas. Nossos resultados mostram que a inserção de fulereno reduz a temperatura de transição nemática-esmética-A, bem como afeta os processos de difusão de calor nas fases nemática e esmética-A. No que diz respeito às propriedades ópticas não-lineares, é observado que a transição de Freedericskz óptica apresenta uma natureza contínua na fase nemática, com o número de anéis de auto-modulação de fase aumentado à medida que intensidade da excitação cresce acima do limiar de Freedericskz. Além disso, é observado que a adição de fulereno aumento significativamente a resposta óptica não-linear do sistema. Usando a técnica de acoplamento de dois feixe e medidas de fotocondutividade no regime estacionário, as propriedades de transporte das amostras dopadas também são analisadas.
|
230 |
Participação do óxido nítrico no desenvolvimento colinérgico e glutamatérgico em regiões visuais de pintos. / Nitric oxide and the development of the cholinergic and glutamatergic systems in the chick visual system.Nathalia de Brito Fuga 26 February 2008 (has links)
o óxido nítrico tem sido apontado como um importante fator de desenvolvimento neural, participando ativamente como sinalizador espacial durante o processo de refinamento sináptico. Avaliamos nesse estudo a participação do óxido nítrico durante esse processo em tectos ópticos de embriões de pintos (Gallus gallus). Para tal avaliamos a imunorreatividade dos neurônios para as proteínas que formam os receptores colinérgicos e glutamatérgicos em diferentes fases do desenvolvimento embrionário, com e sem o bloqueio farmacológico da enzima de síntese do óxido nítrico (NOS). Durante o desenvolvimento embrionário, as subunidades GluR2/3 dos receptores glutamatérgicos são as que aparecem mais precocemente, no 6°dia de desenvolvimento embrionário (E6), juntamente com os neurônios imunorreativos para NOS e somente a partir de E8 é possível identificar a arquitetura laminar típica do tecto óptico.O bloqueio farmacológico da NOS mostrou diferentes padrões de marcação dependendo do tempo de sobrevida do animal. Em animais eutanasiados 24 h após o bloqueio farmacológico observou-se uma alteração na organização das camadas e no padrão radial de organização dos neurônios imunorreativos. Esse dado sugere que haja um atraso no refinamento sináptico, que se reflete em desorganização das camadas do tecto e alterações morfológicas nos neurônios. / O óxido nítrico tem sido apontado como um importante fator de desenvolvimento neural, participando ativamente como sinalizador espacial durante o processo de refinamento sináptico. Avaliamos nesse estudo a participação do óxido nítrico durante esse processo em tectos ópticos de embriões de pintos (Gallus gallus). Para tal avaliamos a imunorreatividade dos neurônios para as proteínas que formam os receptores colinérgicos e glutamatérgicos em diferentes fases do desenvolvimento embrionário, com e sem o bloqueio farmacológico da enzima de síntese do óxido nítrico (NOS). Durante o desenvolvimento embrionário, as subunidades GluR2/3 dos receptores glutamatérgicos são as que aparecem mais precocemente, no 6°dia de desenvolvimento embrionário (E6), juntamente com os neurônios imunorreativos para NOS e somente a partir de E8 é possível identificar a arquitetura laminar típica do tecto óptico.O bloqueio farmacológico da NOS mostrou diferentes padrões de marcação dependendo do tempo de sobrevida do animal. Em animais eutanasiados 24 h após o bloqueio farmacológico observou-se uma alteração na organização das camadas e no padrão radial de organização dos neurônios imunorreativos. Esse dado sugere que haja um atraso no refinamento sináptico, que se reflete em desorganização das camadas do tecto e alteração morfológicas nos neurônios.
|
Page generated in 0.085 seconds