• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 256
  • 136
  • 18
  • 11
  • 8
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 499
  • 211
  • 163
  • 117
  • 104
  • 83
  • 74
  • 71
  • 65
  • 51
  • 51
  • 49
  • 44
  • 43
  • 38
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
401

Análise das propriedades biológicas de um monômero antimicrobiano para aplicação em prótese dentária / Biological properties of an antimicrobial monomer for application in prosthodontics

Regis, Romulo Rocha 11 January 2010 (has links)
A resina acrílica para base de próteses removíveis é capaz de acumular biofilme e assim favorecer o aparecimento de diversos problemas na cavidade bucal dos usuários de próteses. A imobilização de um agente antisséptico na matriz polimérica tem potencial preventivo frente a esse acúmulo, mas necessita de maior investigação. O objetivo deste estudo foi avaliar as propriedades biológicas do brometo de metacriloiloxiundecilpiridínio (MUPB), um composto antisséptico capaz de copolimerizar-se com as resinas acrílicas. Foram determinadas as concentrações inibitória e fungicida/bactericida mínimas (CIM, CFM/CBM) do MUPB frente às espécies Candida albicans, Candida dubliniensis, Candida glabrata, Lactobacillus casei, Staphylococcus aureus e Streptococcus mutans, em comparação ao cloreto de cetilpiridínio (CCP). A seguir, investigou-se a citotoxicidade do MUPB em fibroblastos, comparando-o com o metil metacrilato (MMA). A avaliação da atividade antimicrobiana de diferentes concentrações do MUPB em massa (0, 0,3% e 0,6%) incorporado em uma resina acrílica termopolimerizável para base de próteses foi realizada por meio de testes de difusão em disco e quantificação de unidades formadoras de colônia (UFC) aderidas à resina após contato com suspensões de cada micro-organismo. A adesão microbiana também foi avaliada por microscopia eletrônica de varredura. Comparações entre o MUPB e as demais substâncias, bem como entre as concentrações incorporadas na resina, foram realizadas com α=0,05. O MUPB apresentou CIM inferior ao CCP para C. dublinienses e S. mutans (P=0,046 e 0,043, respectivamente). Para as demais espécies, as diferenças não foram significantes. Para a CFM/CBM, só foi encontrada diferença significante para C. albicans (P=0,046). O MUPB não polimerizado mostrou-se em torno de 20 vezes mais citotóxico que o MMA. Independente da concentração incorporada e da espécie, não houve formação de halo de inibição em torno dos espécimes. A incorporação do MUPB só influenciou na adesão de C. albicans (P=0,003), com menores contagens de UFC para o grupo com 0,6%. Conclui-se que o MUPB não polimerizado tem capacidade antimicrobiana próxima à do CCP, e alta citotoxicidade, se comparado ao MMA. A atividade antimicrobiana, após incorporação em uma resina acrílica para base de prótese, não depende de sua eluição, porém apresentou-se restrita à C. albicans. / Acrylic resins for removable denture base are capable of accumulating biofilm and thus favor the appearance of various problems in the edentulous oral cavity. An antiseptic agent immobilized within the polymeric matrix has a preventive potential against this accumulation, but requires further investigation. The aim of this study was to evaluate the biological properties of methacryloyloxyundecylpyridinium bromide (MUPB), an antiseptic monomer capable of copolymerizing with acrylic resins. The minimum inhibitory and fungicidal/bactericidal concentrations (MIC, MFC/MBC) of MUPB were determined against the species Candida albicans, Candida dubliniensis, Candida glabrata, Lactobacillus casei, Staphylococcus aureus and Streptococcus mutans, in comparison with cetylpyridinium chloride (CCP). After this, the cytotoxicity of MUPB was investigated in fibroblasts, compared with methyl methacrylate (MMA). The antimicrobial activity of different concentrations of MUPB (0, 0.3% and 0.6% w/w) incorporated into a heat polymerized denture base acrylic resin was evaluated by means of disk diffusion tests, and the CFUs adhered to the resin after contact with suspensions of each microorganism were quantified. Microbial adhesion was also evaluated by scanning electron microscopy. Comparisons were made between MUPB and the other substances, as well as between the concentrations incorporated into the resin (α=.05). MUPB presented a lower MIC than CCP for C. dubliniensis and S. mutans (P=.046 and .043, respectively). For the other species, the differences were not significant. For MFC or MBC, significant difference was found only for C. albicans (P=.046). Non polymerized MUPB was shown to be 20 times more cytotoxic than MMA. Irrespective of the concentration incorporated and the species, there was no growth of inhibition halo around the specimens. The incorporation of MUPB only influenced the adhesion of C. albicans (P=.003), with lower CFU counts for the group with the concentration of 0.6%. It was concluded that non polymerized MUPB has an antimicrobial capacity close to that of CCP, and high cytotoxicity when compared with MMA. The antimicrobial activity after incorporation within a denture base acrylic resin did not depend on its elution, but was shown to be restricted to C. albicans.
402

Técnicas de caracterização para avaliação das propriedades mecânicas dos revestimentos de poliuretano acrilado de fibra óptica. / Characterization techniques for evaluation of mechanical properties of acrylic polyurethane coating of optical fiber.

Gualtieri, Carlos Eduardo 16 May 2002 (has links)
A transmissão de dados e informação na fibra óptica vem aumentando nos últimos anos. O interesse para avaliar melhor a confiabilidade mecânica tomou-se uma necessidade, depois que uma fibra, de um cabo instalado, estava se partindo com muita facilidade. O foco principal deste trabalho foi voltado para estabelecer metodologias para avaliar o estado de degradação dos polímeros usados. Através destas técnicas, buscou-se encontrar parâmetros (E\', E\", tan &#948, Tg, etc.) que pudessem indicar o estado de degradação dos revestimentos. Diferentes técnicas foram empregadas para avaliar o revestimento das fibras tais como: calorimetria exploratória diferencial (DSC), diferencial fotocalorimetria (DPC), análise térmica dinâmico mecânico (DMTA) e espectroscopia na região do infravermelho (FIIR). A partir da técnica desenvolvida, DMTA, esta pode ser empregada para avaliar a confiabilidade mecânica de várias fibras comercias. As técnicas DMTA e FIIR mostraram ser muito promissoras, pois consegue-se, através delas, obter muitos dados a respeito das características dos polímeros. / The datas and information transmission in the optical fiber have been increasing in the last years. The interest to evaluate the mechanical reliability became necessary, after that a optical fiber, from a cable installed, was cracking very easily. The principal aim of this work was establishing methodologies to evaluate the polymer degradation state. Through of this techniques we search to find out parameters (E\', E\", tan &#948, Tg. etc) that could denote the degradation state of the coatings. Different techniques were utilized to evaluate the coating of the optical fibers such as: differential scanning calorimeter (DSC), differential photocalorimeter (DPC), dynamic mechanic thermal analyzer (DMTA) and infrared spectroscopy (FIIR). From the method development (DMTA), it was possible to evaluate the mechanical realiability of many commercial fibers. DMTA and FTIR techniques shown to be very promising to obtain very dates to respect of polymer characteristics.
403

Avaliação da cor, corrosão e rugosidade superficial do titânio c.p., ligas metálicas e resina acrílica termopolimerizável sob a ação de soluções higienizadoras / Color, corrosion and surface roughness evaluation of titanium c.p., alloys and heat-polymerized acrylic resin under the action of daily hygiene solutions

Davi, Letícia Resende 03 May 2010 (has links)
A higienização das próteses parciais ou totais removíveis é fundamental para a durabilidade do tratamento e prevenção de patologias orais. O objetivo deste estudo foi avaliar o efeito de agentes higienizadores de prótese na cor, corrosão e rugosidade superficial do titânio c.p., ligas metálicas e resina acrílica termopolimerizável, simulando um período de 180 dias de higienização. Espécimes em formato de discos (12 mm x 3 mm) foram confeccionados em: titânio comercialmente puro (Tritan - Ti c.p.), liga de níquel-cromo-molibdênio-titânio (Vi-Star), liga de níquel-cromo (Fit Cast-SB Plus) e liga de níquel-cromo-berílio (Fit Cast-V). Cada disco fundido foi incluído em mufla previamente preparada por matrizes retangulares de teflon (38 mm x 18 mm x 4 mm), incorporando-se o disco metálico à resina acrílica termopolimerizável. Os corpos-de-prova (n=5) foram imersos em soluções dos agentes higienizadores: hipoclorito de sódio a 0,05%, Periogard, Cepacol, pastilha Corega Tabs, pastilha Medical Interporous e pastilha Polident 3 Minute. Como controle, foi utilizada a água deionizada. Foram realizados ensaios de estabilidade de cor por meio de espectrocolorímetro (Color-guide 45/0), resistência à corrosão por meio da análise visual da presença de manchas no metal e análise da alteração de massa (balança eletrônica analítica), e rugosidade superficial por meio de rugosímetro (Surftest SJ-201P). Além disso, foi realizada análise quantitativa de liberação de íons metálicos por meio de espectrometria de massa com plasma indutivamente acoplado (ICP-MS - ELAN DRC II). Os resultados de estabilidade de cor, alteração de massa e rugosidade foram submetidos à ANOVA e teste de Tukey (p< 0,05). Quanto à estabilidade de cor da resina acrílica termopolimerizável (E), houve diferença estatisticamente significante entre o titânio c.p. e as ligas. A resina associada ao Ti c.p. apresentou menor alteração de cor, enquanto que a resina associada à Fit Cast-SB Plus apresentou a maior alteração de cor (1,33 ± 1,11 e 5,06 ± 1,96, respectivamente). Com relação à presença de manchas no metal, o hipoclorito de sódio causou manchamento nos espécimes das ligas Vi-Star e Fit Cast-V. Quando avaliada a alteração de massa (g), o Cepacol e a pastilha Corega Tabs propiciaram maior perda de massa. Entre os metais, a amostra do Ti c.p. apresentou maior perda de massa. Quanto à rugosidade (Ra, µm) da resina, o Cepacol causou maior rugosidade, enquanto que a pastilha Corega Tabs e o Periogard propiciaram maior lisura no corpo-de-prova. A resina associada ao Ti c.p. e ao Fit Cast-SB Plus apresentaram maior rugosidade. Quanto à rugosidade do metal, os produtos de imersão não influenciaram nos resultados, mas a liga Fit Cast-SB Plus apresentou maior rugosidade após a imersão. A liberação de íons mais expressiva foi constatada nas ligas Vi-Star e Fit Cast-V após a imersão na pastilha Medical Interporous. Pode-se concluir que as ligas Vi-Star e Fit Cast-V podem ser consideradas seguras para a confecção de aparelhos protéticos removíveis, mas com a condição de não utilizar o hipoclorito de sódio a 0,05% ou a pastilha Medical Interporous para a higienização, pois causaram corrosão e maior liberação de íons, respectivamente. / The hygiene care of the removable partial and complete dentures is required for the longevity of the treatment and prevention of oral diseases. The aim of this study was to evaluate the effect of denture cleansers on color, corrosion and surface roughness of the commercially pure titanium, metal alloys and heat-polymerized acrylic resin, simulating a period of 180 days of hygiene. Disk-shaped specimens (12 mm x 3 mm) had been fabricated with commercially pure titanium (Tritan - Ti c.p.), nickel-chromium-molybdenum-titanium alloy (Vi-Star), nickel-chromium alloy (Fit Cast-SB Plus) and nickel-chromium-beryllium alloy (Fit Cast-V). Each cast disc was invested in the flasks previously prepared by Teflon rectangular matrices (38 mm x 18 mm x 4 mm), incorporating the metal disk to the heat-polymerized acrylic resin. The specimens (n= 5) had been immersed in the solutions: sodium hypochlorite 0.05%, Periogard, Cepacol, Corega Tabs, Medical Interporous and Polident 3 Minute. As a control, it was used deionized water. It was accomplished assays of color stability by means of a colorimeter (Color-guide 45/0), corrosion resistance by means of visual analysis of tarnishes on the metal and mass alteration analysis (analytical electronic balance), and surface roughness by means of a surface analyzer (Surftest SJ-201P). Besides, the quantitative analysis of metal ions release was accomplished by means of inductively coupled plasma mass spectrometry (ICP-MS - ELAN DRC II). Color stability, mass alteration and roughness results were submitted to ANOVA and Tukey test (p<0.05). Considering the color stability of the heat-polymerized acrylic resin (E), there were statistically significant difference between the titanium c.p. and the alloys. The resin associated with the Ti c.p. showed lesser color alteration, whereas the resin associated with Fit Cast-SB Plus showed the higher color alteration (1,33 ± 1,11 e 5,06 ± 1,96, respectively). In relation to the presence of tarnishes on the metals, the sodium hypochlorite caused tarnishes on specimens of the Vi-Star and Fit Cast-V alloys. When evaluated the mass alteration (g), Cepacol and Corega Tabs propitiated higher weight loss. Between the metals, the Ti c.p. samples showed greater weight loss. Considering the resin roughness (Ra, µm), Cepacol caused higher roughness, whereas Corega Tabs and Periogard propitiated greater smoothness on the specimens. The resin associated with the Ti c.p. and Fit Cast-SB Plus showed higher roughness. Considering the metal roughness, the immersion products did not influence on the results, but the Fit Cast-SB Plus showed greater roughness after immersion. The ionic release most significant was with the Vi-Star and Fit Cast-V alloys after immersion in Medical Interporous. It could be concluded that the Vi-Star and Fit Cast-V alloys can be considered safe for removable prosthesis finish, but with the condition of do not use sodium hypochlorite 0.05% or Medical Interporous tablet for hygiene, because they caused corrosion and greater ionic release, respectively.
404

Efeito da adição de fibras de vidro particuladas nas propriedades mecânicas de resinas acrílicas utilizadas para a confecção de placas oclusais / Effect of addition of the particulate glass fibers in mechanical properties of acrylic resins used for the making occlusal splints

Soares, Rodrigo Gonçalves 06 July 2010 (has links)
Placas oclusais são dispositivos intraorais utilizados no manejo de pacientes que apresentam desordens do sono, migrânia do tipo tensional e outros. No entanto são os cirurgiões dentistas que predominantemente utilizam as placas oclusais como tratamento do equilíbrio das arcadas dentárias nas disfunções temporomandibulares, prevenção de desgaste dental em pacientes com hábitos parafuncionais e na prevenção de traumas em atletas. Vários métodos têm sido empregados para reforçar resinas acrílicas, como reforço metálico e atualmente a incorporação de diferentes tipos de fibras tais como: carbono, polietileno e vidro. Contudo a adição de fibras de vidro com partículas menores em algumas propriedades mecânicas ainda permanecem desconhecidas. Objetivo: O objetivo desse estudo foi avaliar algumas propriedades mecânicas como a rugosidade de superfície, microdureza, módulo de elasticidade e resistência flexural em resinas acrílicas após a incorporação de fibras de vidro particuladas pré silanizadas. Material e método: Para avaliação das propriedades foram confeccionados vinte e quatro corpos de prova (65 x 10 x 3 mm) de cada marca comercial de resina acrílica, utilizadas para confecção de placas oclusais, Vipi Flash (autopolimerizável), Vipi Wave (termopolimerizável por calor de microondas), Vipi Crill, Lucitone e QC-20 (termopolimerizáveis por calor de banho de água), sendo doze corpos-de-prova controles, e doze experimentais, com adição de 10% em peso de fibras de vidro particuladas (Reforplás S/A, São Paulo, SP, Brasil). Após a realização do acabamento superficial dos corpos de prova com lixas de carborundum e feltros era realizada a avaliação da rugosidade superficial em rugosímetro (Mitutoyo®) com três leituras ao longo dos corpos-de-prova, a microdureza Vickers era analisada em um microdurômetro (Micro Hardness Tester, Shimadzu, Japan) com cinco mensurações em cada corpo-de-prova, e para avaliar os ensaios de resistência flexural e módulo de elasticidade os corpos-de-prova foram avaliados por meio uma máquina de ensaios universal (Emic DL 2000®, Emic, São José dos Pinhais, PR, Brasil), com velocidade de 5mm/min. Os dados foram analisados estatisticamente, usando testes paramétricos e não paramétricos, de acordo com a distribuição da amostra. Resultados: As médias e desvios padrões do teste de rugosidade superficial em Ra foram Vipi Flash sem fibra (0,10 ± 0,03); Vipi Flash com fibra (0,12 ± 0,01); Vipi Wave sem fibra (0,16 ± 0,02); Vipi Wave com fibra (0,13 ± 0,02); Vipi Cril sem fibra (0,12 ± 0,03); Vipi Crill com fibra (0,15 ± 0,03); Lucitone sem fibra (0,10 ± 0,02); Lucitone com fibra (0,09 ± 0,04); QC-20 sem fibra (0,11 ± 0,02) e QC-20 com fibra (0,18 ± 0,03). As médias e desvios-padrão ao teste de microdureza Knoop com relação às marcas comerciais foram: Vipi Flash sem fibra (15,35 ± 0,3); Vipi Flash com fibra (15,51 ± 0,4); Vipi Wave sem fibra (16,60 ± 0,8); Vipi Wave com fibra (17,25 ± 0,9); Vipi Cril sem fibra (17,78 ± 2,27); Vipi Crill com fibra (18,02 ± 1,0); Lucitone sem fibra (15,72 ± 0,3); Lucitone com fibra (16,69 ± 0,6); QC-20 sem fibra (15,91 ± 0,4) e QC-20 com fibra (15,63 ± 0,2). As médias e desvios-padrão ao teste de módulo de elasticidade foram: Vipi Flash sem fibra (2952,76 ± 292,12); Vipi Flash com fibra (3373,49 ± 403,76); Vipi Wave sem fibra (2511,69 ± 304,09); Vipi Wave com fibra (3225,01 ± 248,66); Vipi Cril sem fibra (2745,61± 288,86); Vipi Crill com fibra (3671,67 ± 329,91); Lucitone sem fibra (1904,53 ± 149,05); Lucitone com fibra (3056,87 ± 126,11); QC-20 sem fibra (1913,86 ± 147,80) e QC-20 com fibra (2858,32 ± 185,26). As médias e desvios-padrão ao teste de resistência flexural foram Vipi Flash sem fibra (81,62 ± 4,82); Vipi Flash com fibra (83,98 ± 4,98); Vipi Wave sem fibra (83,52 ± 8,79); Vipi Wave com fibra (88,98± 8,47); Vipi Cril sem fibra (64,17± 5,46); Vipi Crill com fibra (93,37 ± 9,97); Lucitone sem fibra (74,71± 9,43); Lucitone com fibra (87,29 ± 4,73); QC-20 sem fibra (75,80 ± 8,82) e QC-20 com fibra (81,67± 12,97). Conclusão: Conclui-se que a incorporação de fibras provocou alterações em praticamente todas as propriedades analisadas, sendo, portanto facilmente utilizável como um reforço adicional às resinas acrílicas. Com relação à dureza superficial as resinas acrílicas termopolimerizável por banho de água e termopolimerizável por calor de microondas apresentaram maiores valores quando comparados com a resina acrílica autopolimerizável. Além disso, a adição de fibras de vidro particuladas aumentou os valores de rugosidade de algumas resinas acrílicas Vipi Crill, Vipi Flash e Vipi Wave e se manteve constante nas resinas Lucitone e QC-20. A adição de fibra de vidro não aumentou significantemente a microdureza Knoop nos grupos em estudo. Com relação à resistência flexural as fibras de vidro particuladas aumentaram significantemente todos os valores, assim como o módulo de elasticidade das resinas acrílicas reforçadas pela adição de fibras de vidro. / Intraoral Occlusal splints are devices used in the management of patients with sleep disorders, migraine type tension and others. But dentists who are predominantly using the plates as a treatment of occlusal balance of the dental arches in temporomandibular disorders, prevention of tooth wear in patients with habits and prevention of injuries in athletes. Several methods have been used to strengthen acrylic resins, such as metal reinforcement and are currently incorporating different types of fibers such as carbon, polyethylene and glass. However the addition of glass fibers with smaller particles on mechanical properties are still unknown. Objective: The objective of this study was to evaluate some mechanical properties such as surface roughness, hardness, elastic modulus and flexural strength in acrylic resins after the incorporation of glass fiber particulate pre silanized. Methods: To evaluate the properties were made twenty-four specimens (65 x 10 x 3 mm) of each brand of acrylic resin, used for fabrication of occlusal splints, Vipi Flash (self-curing), Vipi Wave (by thermo microwave heat), Vipi CRILL, Lucitone and QC-20 (thermo heat water bath), with twelve specimes controls, and twelve experimental, with the addition of 10 wt% glass fiber particulate (Reforplás S / A, São Paulo, Brazil). After completion of the roughness of the specimens with grit carborundum and felt it was evaluated the surface roughness on roughness tester (Mitutoyo ®) with three readings over the specimes, the microhardness was examined with a hardness ( Micro Hardness Tester, Shimadzu, Japan) with five measurements in each specime, and evaluate the tests for flexural strength and modulus of elasticity of the specimes was evaluated using a universal testing machine (Emic DL 2000 ®, Emic, São José dos Pinhais, PR, Brazil), with speed 5mm/min. The data were statistically analyzed using parametric and nonparametric tests, according to the sample distribution. Results: The mean and standard deviation of the test surface roughness were Vipi Flash without fiber (0.10 ± 0.03); Flash Vipi with fiber (0.12 ± 0.01); Vipi Wave without fiber (0, 16 ± 0.02); Vipi Wave with fiber (0.13 ± 0.02); Vipi Cril without fiber (0.12 ± 0.03); Vipi CRILL with fiber (0.15 ± 0.03); Lucitone without fiber (0.10 ± 0.02); Lucitone with fiber (0.09 ± 0.04), QC-20 fiber without (0.11 ± 0.02) and QC-20 with fiber (0.18 ± 0.03). Means and standard deviations for Knoop microhardness test with respect to trademarks were Vipi Flash without fiber (15.35 ± 0.3); Flash Vipi with fiber (15.51 ± 0.4); Vipi Wave without fiber (16.60 ± 0.8); Vipi Wave with fiber (17.25 ± 0.9); Vipi Cril without fiber (17.78 ± 2.27); Vipi CRILL with fiber (18.02 ± 1.0 ); Lucitone without fiber (15.72 ± 0.3); Lucitone with fiber (16.69 ± 0.6), QC-20 without fiber (15.91 ± 0.4) and QC-20 with fiber (15 , 63 ± 0.2). Means and standard deviations to test elastic modulus were Vipi Flash without fiber (2952.76 ± 292.12); Flash Vipi with fiber (3373.49 ± 403.76); Vipi Wave without fiber (2511.69 ± 304.09); Vipi Wave with fiber (3225.01 ± 248.66); Vipi Cril without fiber (2745.61 ± 288.86); Vipi CRILL with fiber (3671.67 ± 329.91); Lucitone without fiber (1904.53 ± 149.05); Lucitone with fiber (3056.87 ± 126.11), QC-20 without fiber (1913.86 ± 147.80) and QC-20 with fiber (2858.32 ± 185 26). Means and standard deviations for flexural strength were Vipi Flash without fiber (81.62 ± 4.82); Flash Vipi with fiber (83.98 ± 4.98); Vipi Wave without fiber (83.52 ± 8 , 79); Vipi Wave with fiber (88.98 ± 8.47); Vipi Cril without fiber (64.17 ± 5.46); Vipi CRILL with fiber (93.37 ± 9.97); Lucitone without fiber ( 74.71 ± 9.43); Lucitone with fiber (87.29 ± 4.73), QC-20 without fiber (75.80 ± 8.82) and QC-20 with fiber (81.67 ± 12.97). Conclusion: the conclusion is that the incorporation of fibers resulted in changes in almost all properties examined, and thus easily used as an additional reinforcement for acrylic resins. With respect to the surface roughness of acrylic resins by thermo water bath and microwave thermo heat showed higher values when compared with acrylic resin. Moreover, the addition of glass fiber particulate increased the roughness values of some acrylic resins Vipi CRILL, Vipi Flash and Vipi Wave and remained constant in the resins Lucitone and QC-20. The addition of glass fiber does not increase significantly the microhardness in the groups. With respect to flexural strength glass fiber particulate significantly increased all values, as well as the modulus of acrylic resin reinforced by the addition of glass fibers.
405

Análise das propriedades biológicas de um monômero antimicrobiano para aplicação em prótese dentária / Biological properties of an antimicrobial monomer for application in prosthodontics

Romulo Rocha Regis 11 January 2010 (has links)
A resina acrílica para base de próteses removíveis é capaz de acumular biofilme e assim favorecer o aparecimento de diversos problemas na cavidade bucal dos usuários de próteses. A imobilização de um agente antisséptico na matriz polimérica tem potencial preventivo frente a esse acúmulo, mas necessita de maior investigação. O objetivo deste estudo foi avaliar as propriedades biológicas do brometo de metacriloiloxiundecilpiridínio (MUPB), um composto antisséptico capaz de copolimerizar-se com as resinas acrílicas. Foram determinadas as concentrações inibitória e fungicida/bactericida mínimas (CIM, CFM/CBM) do MUPB frente às espécies Candida albicans, Candida dubliniensis, Candida glabrata, Lactobacillus casei, Staphylococcus aureus e Streptococcus mutans, em comparação ao cloreto de cetilpiridínio (CCP). A seguir, investigou-se a citotoxicidade do MUPB em fibroblastos, comparando-o com o metil metacrilato (MMA). A avaliação da atividade antimicrobiana de diferentes concentrações do MUPB em massa (0, 0,3% e 0,6%) incorporado em uma resina acrílica termopolimerizável para base de próteses foi realizada por meio de testes de difusão em disco e quantificação de unidades formadoras de colônia (UFC) aderidas à resina após contato com suspensões de cada micro-organismo. A adesão microbiana também foi avaliada por microscopia eletrônica de varredura. Comparações entre o MUPB e as demais substâncias, bem como entre as concentrações incorporadas na resina, foram realizadas com &alpha;=0,05. O MUPB apresentou CIM inferior ao CCP para C. dublinienses e S. mutans (P=0,046 e 0,043, respectivamente). Para as demais espécies, as diferenças não foram significantes. Para a CFM/CBM, só foi encontrada diferença significante para C. albicans (P=0,046). O MUPB não polimerizado mostrou-se em torno de 20 vezes mais citotóxico que o MMA. Independente da concentração incorporada e da espécie, não houve formação de halo de inibição em torno dos espécimes. A incorporação do MUPB só influenciou na adesão de C. albicans (P=0,003), com menores contagens de UFC para o grupo com 0,6%. Conclui-se que o MUPB não polimerizado tem capacidade antimicrobiana próxima à do CCP, e alta citotoxicidade, se comparado ao MMA. A atividade antimicrobiana, após incorporação em uma resina acrílica para base de prótese, não depende de sua eluição, porém apresentou-se restrita à C. albicans. / Acrylic resins for removable denture base are capable of accumulating biofilm and thus favor the appearance of various problems in the edentulous oral cavity. An antiseptic agent immobilized within the polymeric matrix has a preventive potential against this accumulation, but requires further investigation. The aim of this study was to evaluate the biological properties of methacryloyloxyundecylpyridinium bromide (MUPB), an antiseptic monomer capable of copolymerizing with acrylic resins. The minimum inhibitory and fungicidal/bactericidal concentrations (MIC, MFC/MBC) of MUPB were determined against the species Candida albicans, Candida dubliniensis, Candida glabrata, Lactobacillus casei, Staphylococcus aureus and Streptococcus mutans, in comparison with cetylpyridinium chloride (CCP). After this, the cytotoxicity of MUPB was investigated in fibroblasts, compared with methyl methacrylate (MMA). The antimicrobial activity of different concentrations of MUPB (0, 0.3% and 0.6% w/w) incorporated into a heat polymerized denture base acrylic resin was evaluated by means of disk diffusion tests, and the CFUs adhered to the resin after contact with suspensions of each microorganism were quantified. Microbial adhesion was also evaluated by scanning electron microscopy. Comparisons were made between MUPB and the other substances, as well as between the concentrations incorporated into the resin (&alpha;=.05). MUPB presented a lower MIC than CCP for C. dubliniensis and S. mutans (P=.046 and .043, respectively). For the other species, the differences were not significant. For MFC or MBC, significant difference was found only for C. albicans (P=.046). Non polymerized MUPB was shown to be 20 times more cytotoxic than MMA. Irrespective of the concentration incorporated and the species, there was no growth of inhibition halo around the specimens. The incorporation of MUPB only influenced the adhesion of C. albicans (P=.003), with lower CFU counts for the group with the concentration of 0.6%. It was concluded that non polymerized MUPB has an antimicrobial capacity close to that of CCP, and high cytotoxicity when compared with MMA. The antimicrobial activity after incorporation within a denture base acrylic resin did not depend on its elution, but was shown to be restricted to C. albicans.
406

Incorporação de ácido metacrílico em resinas acrílicas para base de prótese / Incorporation of methacrylic acid in denture base acrylic resins

Alessandra Miranda de Azevedo 30 June 2009 (has links)
A resina acrílica para base de próteses removíveis é capaz de aderir Candida spp. sobre sua superfície, possibilitando o aparecimento das estomatites protéticas. Um fator importante para essa aderência é a hidrofobicidade do polímero. Assim, a adição de radicais hidrofílicos à resina acrílica tem potencial de torná-la menos suscetível à formação de biofilmes, e merece ser investigado. O objetivo deste projeto foi avaliar os efeitos da copolimerização do ácido metacrílico sobre aderência microbiana e propriedades físicas em um material à base de polimetil metacrilato para base de próteses removíveis. Para os ensaios com a resina acrílica, espécimes de diferentes formatos foram divididos em grupos, conforme a concentração do ácido metacrílico, em volume, na porção líquida da resina (A: 0%; B: 10%; C: 20%, D:50%). A aderência de Candida albicans foi avaliada por meio da contagem de unidades formadoras de colônia (UFC) aderidas sobre os espécimes mantidos em caldo de cultura. Também foi estudadas a dureza Vickers, a resistência flexural, a rugosidade e a estabilidade de cor. Os grupos foram descritos por média ± desvios padrão e comparados, dentro de cada variável, por meio de ANOVA, com &alpha; = 0,05. No caso da aderência de C. albicans, transformação em log10 foi realizada antes da análise. Como resultado desse estudo, não foi possível observar diferenças na aderência de C. albicans com a adição do ácido metacrílico à resina acrílica (A: 5,0 ± 0.4, B: 5,0 ± 0.4, C: 5.2 ± 0.6 e D: 5.2 ± 0.3 log10(UFC)). Redução significante foi encontrada para os valores de dureza, onde os valores (em VHN) foram A: 19,0 ± 1,4A, B: 19,6 ± 1,3A, C: 19,6 ± 0,9A e D: 14,2 ± 0,6B. Não houve diferença significante para o teste de resistência flexural (A: 96,32 ± 8,25, B: 97,65 ± 6,11, C: 102,43 ± 8,61 e D: 106,34 ± 13,69 MPa); no entanto foi observada redução na rugosidade superficial com o aumento da concentração do ácido (A: 0,26 ± 0,05A, B: 0,17 ± 0,01B, C: 0,18 ± 0,03B e D: 0,13 ± 0,03C &micro;m). Conclui-se que a copolimerização do ácido metacrílico em resina para base protética proporcionou mudanças nas propriedades físicas do material, com melhora na rugosidade, porém menor dureza. A aderência de C. albicans não sofreu interferência; futuros testes com outras espécies e na presença de proteínas salivares devem ser realizados a fim de determinar se a adição do ácido realmente possui potencial clínico. / Acrylic resins for denture base play an important role as reservoirs of micro-organisms, by increasing the risk of Candida ssp. colonization which is implicated in the pathogenesis of associated stomatitis. An important factor for this adherence is the polymer hydrophobicity. Thus, incorporation of polar radicals in the polymer could increase its hydrophylia, reducing this adherence. The main purpose of the present study was to investigate the antifungal activity of a denture base resin incorporating the methacrylic acid (MA) against Candida albicans by the counting of adherent cells and its effect on hardness, roughness and flexural strength of the material. 32 circular (14x4mm), 40 rectangular (65x10x3.3mm) and 40 square-shaped (10x10x3mm) specimens were divided into four groups, according to the concentration of MA substituted into the monomer component of a heat-polymerized acrylic resin (Lucitone 550), as follows: 0% (Control), 10%, 20% and 50% (v/v). Hardness was assessed by a hardness tester equipped with a Vickers diamond penetrator. A surface roughness tester was used to measure the surface roughness of the specimens, and a flexural strength testing was carried out on a universal testing machine. Variables were analyzed by ANOVA/Tukey\'s test (&alpha;=.05). Colonies were counted for each plated specimen and the colony-forming units per milliliter (CFU/mL) were then calculated. CFU/mL values for each concentration were compared by means of ANOVA/Tukey test after logarithmic (log 10) transformation (&alpha;=.05). A significant difference was found for hardness values (19.0±1.4A, 19.6±1.3A, 19.6±0.9A, 14.2±0.6B) VHN. Surface roughness values decreased with MA concentration increase (0.26±0.05A, 0.17±0.01AB, 0.18±0.03AB, 0.13±0.03B &micro;m). No significant difference was found for flexural strengh (96.3±8.3A, 97.7±6.1A, 102.4±8.6A, 106.3±13.7A MPa) and among the four groups for the adherence assay (A: 5,0 ± 0.4, B: 5,0 ± 0.4, C: 5.2 ± 0.6 e D: 5.2 ± 0.3 log10 (CFU). For the tested acrylic resin, the addition of MA in the concentration of 50% reduced its hardness. Thus, the presence of MA around this concentration inside the monomer may compromise the tested material structure. Although MA didnt lower the flexural strength, regardless of the concentration, the values for surface roughness reduced as MA concentration increased, suggesting that MA addition may improve the acrylic resin texture, leading to less biofilm accumulation. The adherence of C. albicans was not influenced by the presence of MA. Future tests with other microorganisms and salivary proteins should be carried out to determine if this incorporation has a clinical potencial to be used.
407

Caracterização da relaxação por compressão de borracha acrílica irradiada. / Compression relaxation characterization of irradiated acrylic rubber.

Santos, Demetrio Jackson dos 11 February 2011 (has links)
Este trabalho tem como objetivo investigar a redução da relaxação por compressão de borracha acrílica modificada (ACM) irradiada por feixe de elétrons, através da caracterização de seu comportamento mecânico e de sua estrutura molecular. O material, nas condições original e irradiado, foi inicialmente submetido a ensaios uniaxiais de tração e espectroscopia por infravermelho com o objetivo de verificar a influência da irradiação EB em seu comportamento, eliminando a possibilidade de degradação do material, permitindo a continuidade dos estudos. Definidas as doses, novos corpos de prova foram irradiados e submetidos a ensaios uniaxiais, equibiaxiais de tensão e cisalhamento puro, gerando resultados que foram aplicados na simulação pelo método de elementos finitos, utilizando o modelo de comportamento elástico não-linear de Ogden, para predizer o comportamento do material em condições de compressão. Confirmado o aumento da tensão por compressão para mesmas deformações, com o aumento da dose de radiação, análises termogravimétricas e dinâmicas mecânicas foram realizadas para possibilitar o entendimento do fenômeno. Na fase final do trabalho ensaios de relaxação por compressão foram realizados, em diferentes níveis de deformação e temperatura, apresentando a redução da relaxação por compressão gerada pela radiação EB e quantificando tal influência combinada com outros fatores, através da aplicação dos resultados no método de Planejamento Fatorial 2k. / The aim of this work is to investigate the compression stress relaxation (CSR) decrease of modified acrylic rubber, irradiated by electron beam, through its mechanical behavior and molecular structure characterization. Uniaxial tensile test and infrared spectroscopy were carried out, on original and irradiated material conditions, to verify the influence of EB irradiation on ACM, and to eliminate the possibility of degradation caused by EB radiation. After to define the radiation doses, new ACM specimens were irradiated. Uniaxial, equibiaxial and planar shear tests generated experimental data, which were applied to simulate the non linear elastic behavior of the material, through finite elements method, using the Ogden Model. Confirmed the compression stress increase at same deformation level, caused by increasing of radiation dose, thermogravimetric and dynamic mechanical analysis were carried out in order to make possible to understand the behavior changes. In the final part of this work, compression stress relaxation experiments were carried out, at two deformation and temperature levels, with the purpose to validate the compression stress relaxation decrease caused by EB radiation, and to quantify such influence combined with other factors. The CSR decrease combined with other influence variables were studied through use of factorial design.
408

Efetividade da escovação com diferentes agentes de limpeza de próteses na redução da viabilidade de biofilme in vitro da candida albicans /

Pellizzaro, Delise. January 2011 (has links)
Orientador: Carlos Eduardo Vergani / Banca: Eunice Teresinha Giampaolo / Banca: Cláudia Helena Lovato da Silva / Resumo: A Candida albicans tem sido considerada o principal agente etiológico da estomatite protética, uma das infecções mais comumente observadas em pacientes usuários de próteses removíveis. A adesão de C. albicans à superfície das próteses é o primeiro passo para o desenvolvimento da estomatite protética. Assim, uma adequada higienização das próteses é essencial para prevenir a formação de biofilme microbiano sobre a superfície protética e, conseqüentemente, o início e propagação desta infecção. O objetivo deste estudo foi avaliar a efetividade da escovação com diferentes soluções (água destilada, dentifrício, digluconato de clorexidina a 2%, hipoclorito de sódio a 1% e Polident fresh cleanse®) na redução da viabilidade de um biofilme maduro de C. albicans, desenvolvido sobre uma resina termopolimerizável para base de prótese. Para isso, 90 corpos-de-prova circulares foram confeccionados, esterilizados e inoculados com uma suspensão de 107 células/mL de C. albicans. Para a formação do biofilme, todos os corpos-de-prova foram incubados por 48 h a 37 °C sob agitação. A seguir, os corpos-de-prova foram aleatoriamente divididos (n=9) e individualmente submetidos à escovação ou exposição por 90 s nas diferentes soluções avaliadas. Os espécimes imersos em água destilada pelo mesmo período de tempo foram utilizados como controle positivo. Para verificar a efetividade da escovação e dos agentes de limpeza, os corpos-de-prova foram submetidos à avaliação da atividade metabólica das células não removidas de C. albicans por meio do teste do XTT. Os resultados obtidos foram analisados estatisticamente pelos testes de Mann-Whitney e Kruskal-Wallis (α=0.05). A escovação com todos os agentes de limpeza apresentou redução significativamente superior (p<0,0001) na viabilidade do biofilme quando comparada à exposição dos corpos-de-prova... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The adhesion of C. albicans to surfaces is the prerequisite for occurrence of denture stomatitis, a common disease diagnosed among denture wearers. Therefore, a strict routine of denture cleansing is essential to prevent biofilm formation on the acrylic denture surface and the onset of this infection. Thus, the aim of the current study was to investigate the effectiveness of combining toothbrushing and cleansing agents (dentifrice, 2% chlorhexidine gluconate, 1% sodium hypochlorite, and Polident fresh cleanse®) in inactivating C. albicans biofilm. Circular specimens (10 x 2 mm) of acrylic resin denture base material were made, sterilized, and individually inoculated with C. albicans (1x107 colony-forming units/mL). After incubation (37 °C/48 h), the specimens were divided into 10 experimental groups (n=9): 5 subjected to toothbrushing with different cleansing agents and 4 exposed to the cleansing agents without toothbrushing. Non-cleansed specimens were used as positive controls. The viability of cells was evaluated by XTT reduction method. Mann-Whitney and Kruskal-Wallis tests were used for comparative analysis between the two methods of cleansing and the cleansing agents, respectively (α=0.05). Toothbrushing with all agents was significantly more effective (p<0.0001) in reducing biofilm viability than exposure to the cleansing agents only. Exposure to all cleansing agents reduced significantly (p<0.0001) the biofilm viability, with 2% chlorhexidine gluconate being most effective (p<0.0001). Toothbrushing with 2% chlorhexidine gluconate and 1% sodium hypochlorite resulted in 100% inactivation of the biofilm. The use of cleansing agents as an adjunct to toothbrushing is an effective method to reduce C. albicans biofilm viability on denture base resins. / Mestre
409

Síntese e caracterização de polímero híbrido acrílico-alquídico produzido por polimerização em miniemulsão. / Synthesis and characterization of alkyd-acrylic hybrid polymer produced by miniemulsion polymerization.

Badin, Caroline 06 February 2015 (has links)
Polímeros híbridos são caracterizados por conter numa mesma partícula dois tipos diferentes de polímero, normalmente incompatíveis e ligados por ligações covalentes. Neste trabalho, a síntese de um polímero híbrido acrílico-alquídico pelo processo de miniemulsão foi investigada. Com o objetivo de compreender como diferentes variáveis na fórmula afetam as características físico-químicas finais do látex, um planejamento experimental foi desenhado com o auxílio do software DX9 e os resultados analisados por modelos empíricos de superfície de resposta. Os fatores variados (variáveis independentes) foram: quantidade de co-estabilizante, surfactante e iniciador. Cada um dos fatores contribuiu para a alteração de pelo menos uma característica avaliada, e a sinergia entre eles afeta diretamente o teor de RDG, resposta indicativa do grau de grafitização entre as espécies. O coestabilizante contribuiu para o aumento do diâmetro médio de gotas e da polidispersidade de tamanho de partículas, enquanto reduziu a dureza do filme. A concentração de surfactante alterou o número de partículas por litro, reduzindo o diâmetro médio de partículas e aumentando a polidispersidade. O iniciador aumentou a conversão monomérica. Todas as dispersões de polímero híbrido produzidas apresentaram redução do tamanho médio de gotas para partículas, indicando evidência de nucleação secundária. As avaliações por microscopia eletrônica de transmissão (TEM) e microscopia de força atômica (AFM) mostraram que a morfologia obtida é do tipo núcleo-casca. / Hybrid polymers are defined by the presence of two or more different kinds of polymers in the same particle, typically incompatible and linked by covalent bonds. In this work, the synthesis of an alkyd-acrylic hybrid polymer produced by miniemulsion polymerization has been investigated. With the goal of understanding how different variables in the recipe affect the final characteristics of the latex, a design of experiment was planned using DX9 software and the results were analyzed by response surface methodology. The factors studied (independent variables) were: amount of co-stabilizer, surfactant and initiator. Each of these factors contributed to change at least one of the evaluated characteristics, and the synergy between them directly affects the RDG content, response of the polymer degree of grafting. Costabilizer contributed to increase the average droplets diameter and polydispersity of particle size, while reducing the film hardness. The amount of surfactant changed the number of particles, reducing the average particle size and increasing polydispersity. Initiator increased the monomer conversion. All hybrids dispersions presented a decrease in the droplet size to particle size, indicating evidence of secondary nucleation. Core-shell morphology was observed through transmission electron microscopy (TEM) and atomic force microscopy (AFM).
410

S?ntese e caracteriza??o de l?tices acr?licos reticulados com (1,6-diacrilato propoxilato hexanodiol) via polimeriza??o em emuls?o

Silva, Guymmann Clay da 29 February 2008 (has links)
Made available in DSpace on 2014-12-17T15:41:41Z (GMT). No. of bitstreams: 1 GuymmannCS.pdf: 1754712 bytes, checksum: 731ccc6c9bb4f783f3a118094959297b (MD5) Previous issue date: 2008-02-29 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior / Latices based on acrylic acid and ethyl methacrylate, crosslinked with 1,6&#8208;propoxylate&#8208;hexanodiol diacrylate were synthesized via emulsion polymerization with different monomeric compositions. The resultant latices were thickened with different NaOH/(acrylic acid) molar ratios and were characterized by titrimetry, zeta potential measurements, turbidimetry, and capillary viscometry. Intrinsic viscosity was determined for an uncrosslinked copolymer, using toluene as solvent. All the latices were coagulated with NaCl and washed with water at 60?C analyzed by FTIR spectrophotometry, in order to characterize functional groups from the copolymer and crosslinking agent. / L?tices ? base de ?cido acr?lico e metacrilato de etila, reticulados com 1,6&#8208;diacrilato de propoxilato hexanodiol, foram sintetizados via polimeriza??o em emuls?o, com diferentes composi??es monom?ricas. Os l?tices sintetizados foram espessados com diferentes raz?es molares NaOH/(?cido acr?lico) e caracterizados por titrimetria, medidas de potencial zeta, turbidimetria e viscometria capilar. Todos os l?tices foram coagulados com NaCl, lavados com ?gua destilada e em seguida secos a 60 0C, para a an?lise de FTIR. A viscosidade intr?nseca do l?tex n?o reticulado foi determinada utilizando tolueno como solvente. O potencial zeta foi usado para determinar a carga superficial das part?culas e o FTIR para caracterizar os grupos funcionais dos comon?meros.

Page generated in 0.0269 seconds