• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 456
  • 24
  • 24
  • 24
  • 22
  • 16
  • 8
  • 6
  • 1
  • 1
  • 1
  • Tagged with
  • 471
  • 471
  • 160
  • 96
  • 64
  • 57
  • 40
  • 34
  • 33
  • 32
  • 29
  • 25
  • 24
  • 20
  • 20
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
381

Modulação autônoma da resposta taquicárdica do exercício pela ocitocina endógena no complexo solitário vagal em ratos sedentários e treinados, normotensos e hipertensos. / Autonomic modulation of exercise tachycardia by endogenous oxytocin into the solitary vagal complex in sedentary and trained, normotensive and hypertensive rats.

Taniguchi, Keila Tomoko Higa 28 April 2008 (has links)
Utilizando Análise Espectral (FFT) para quantificar a variabilidade autonômica no animal intacto, analisamos pressão arterial, intervalo de pulso (IP) e fluxo sangüíneo no repouso e no exercício, em ratos normotensos (WKY) e hipertensos (SHR), sedentários (S) ou treinados (T), após pré-tratamento do NTS/DMV com veículo e antagonista de ocitocina (OTant). As principais alterações foram relacionadas à freqüência cardíaca (FC) e ao IP: bradicardia de repouso em WKYT e SHRT; aumento na resposta taquicárdica do exercício após OTant apenas nos WKYT. No repouso, os SHR apresentaram queda da variância do IP com diminuição dos componentes de baixa (LF-simpático) e alta (HF-vago) freqüências, corrigidas pelo T. No exercício houve queda dos componentes espetrais do IP nos grupos experimentais, exceto o HF que não diminuiu nos WKYT. OTant no NTS/DMV reduziu o HF dos SHRT no repouso e exercício; a ausência da queda do HF nos WKYT foi abolida. Resultados indicam a importância da ocitocina agindo sobre o vago na modulação da FC basal e da taquicardia do exercício apenas em T. / Using Spectral Analysis (FFT) to quantify the autonomic variability in intact animal, we analyzed blood pressure, pulse interval (PI) and blood flow at rest and during exercise, in normotensive (WKY) and hypertensive (SHR) rats, sedentary (S) or trained (T), after solitary vagal complex (NTS/DMV) pre-treatment with vehicle and oxytocin antagonist (OTant). The main changes were related to heart rate (HR) and PI: rest bradycardia in WKYT and SHRT; increased exercise tachycardia after OTant only in WKYT. At rest, SHR presented a fall of in PI variance with decreased low (LF-simpathetic) and high (HF-vagal) frequencies components that were normalized by T. During exercise, the spectral components decreased in the experimental groups, except HF unchanged in WKYT. OTant into the NTS/DMV reduced the HF of the SHRT at rest and exercise; the absence of the fall in HF of WKYT was abolished. Results indicate the importance of oxytocin acting on vagus in the modulation of basal HR and exercise tachycardia only in T rats.
382

Avaliação dos ruidos articulares como diagnóstico complementar de desordens temporomandibulares / Assessment of temporomandibular joint sounds as a complementary diagnosis in temporomandibular disorders

Kanashiro, Marcus Vinicius Yamazato 02 September 2011 (has links)
O ruído articular é comumente reconhecido como um sinal de desarranjo articular, e a sua análise faz parte do conjunto de dados coletados em vários sistemas de classificação e diagnóstico, tanto em pesquisas como nas atividades clínicas. Apesar desta importância, existe ainda dificuldade na interpretação dos sons, em virtude da variação natural do fenômeno, do subjetivismo por parte de examinadores e dos métodos e equipamentos empregados para o diagnóstico. Visando uma análise mais objetiva, foi desenvolvido um dispositivo para gravar e analisar graficamente os sons. Este método permite o armazenamento e sucessivas análises, eliminando ainda diferenças de percepção de sons entre os examinadores. O objetivo da pesquisa é verificar a eficácia do dispositivo desenvolvido efetuando a comparação com exames de ressonância magnética (RM). A concordância entre os examinadores e as análises das gravações também foram feitas, para se verificar o subjetivismo das percepções. Pacientes com idade entre 14 a 75 anos e que reportaram dor muscular e/ou a presença de sons articulares foram incluídos na pesquisa. Foram excluídos aqueles que já tivessem recebido tratamento prévio, apresentassem dores de cabeça, infecções, traumas faciais recentes, patologias sistêmicas, gravidez ou marca passos. De acordo com estes critérios, uma amostra de 18 pacientes foi selecionada para a pesquisa. Os pacientes tiveram os ruídos articulares detectados com o método de palpação e por estetoscópios , por quatro examinadores, e os sons então foram gravados e analisados, com o dispositivo desenvolvido. Por fim, as percepções dos sons por todos os métodos realizados na pesquisa foram aplicadas ao protocolo RDC/TMD, e diagnósticos para cada paciente foram obtidos. Desta forma, foi feita a comparação com os exames de ressonância magnética (RM), adotado como padrão ouro na pesquisa. O critério estatístico de Altman mostrou uma concordância em termos de valores de kappa muito baixa entre os quatro examinadores. Nos ciclos de abertura, de acordo com os resultados obtidos no estudo, o examinador 2 (método de palpação) apresentou uma fraca concordância com os examinadores 3 e 4, (método de estetoscópios), (k=0.272 e k=0.397, respectivamente). O examinador 3 apresentou uma boa concordância com o examinador 4 (k=0.698). Nos ciclos de fechamento, o examinador 3 apresentou uma fraca concordância com o examinador 4 (k=0.398). Na comparação entre as gravações e os examinadores, verificou-se a falta de concordância entre estes, com valores de kappa muito baixos, quando possíveis de serem calculados (k=0.021 até k=0.147). Quando os diagnósticos obtidos pelo RDC/TMD por todos os métodos foram comparados com os laudos de RM, a gravação apresentou melhor percentual de concordância (55,6%), em relação à percepção de som pelos examinadores (36,1% a 52,8%). O dispositivo desenvolvido para análise e gravação dos ruídos articulares mostrou ser um método de fácil manuseio e visualização, conseguindo uma superior detecção de ruídos. A comparação com exames de RM confirmou esta melhora. / The joint noise is commonly recognized as a sign of an articular derangement, and its analysis is part of the data set collected in many systems of classification and diagnosis, both in research and clinical activities. Despite this importance, there is some difficulty in interpreting the sounds due to the natural variability of the phenomenon, subjectivism by examiners and the methods and equipments used for diagnosis. In order to get a more objective analysis, we developed a device to record and graphically analyze the sounds. This method allows the storage and subsequent analysis, even eliminating differences in perception of sound between the examiners. The present research aims to verify the effectiveness of the device developed by comparisons with magnetic resonance imaging (MRI). The agreement between the examiners and the analysis of the recordings were also made to verify the subjectivity of perception. Patients aged 14 to 75 years who reported muscle pain and / or the presence of joint sounds were included in the survey. We excluded those who had already received previous treatment, experience headaches, infections, recent facial trauma, systemic diseases, and pregnancy or pacemakers users. According to these criteria, a sample of 18 subjects was selected for the survey. The patients had joint noises detected with the methods of palpation and stethoscope by four examiners, and the sounds were recorded and then analyzed with the developed device. Finally, perceptions of the sounds made by all methods were applied in the research protocol RDC / TMD, and diagnoses for each patient were obtained. Finally, the comparison was made with magnetic resonance imaging (MRI), adopted as the gold standard in research. From the results, according to Altman criteria, there was an agreement in terms of very low kappa values among the four examiners. In cycles of opening, according to the results obtained in the study, the examiner 2 (palpation method) showed a poor agreement with the examiners 3 and 4 (method of stethoscopes), (k = 0272 k = 0397, respectively). The examiner 3 had good agreement with the examiner 4 (k = 0698). In closing cycles, the examiner 3 had a poor agreement with the examiner 4 (k = 0398). In the comparison between the recordings and the examiners, there was a lack of agreement among these, with very low kappa values when possible to be calculated (k = k = 0021 to 0147). When the diagnoses obtained by RDC / TMD by all methods were compared with the findings of MRI, the recording method showed the best percentage of agreement (55.6%) compared to the perception of sound by the examiners (36.1 to 52%, 8%). The device developed for recording and analyzing the joint sounds proved to be an easy method of handling and display, achieving a better detection of the noise. The comparison with MRI confirmed this improvement.
383

Estimativa dos parâmetros acústicos em uma mistura de líquidos imiscíveis durante o processo de separação de fases / Acoustic parameters estimative for a mixture of inmiscible liquids during its dynamic phases separation process

Villamarín Muñoz, Julián Antonio 14 November 2007 (has links)
Esta pesquisa estuda a evolução temporal dos parâmetros de propagação acústica de uma mistura de líquidos imiscíveis considerada como emulsão instável durante o processo de separação de suas fases. O principal objetivo neste trabalho é estudar o comportamento não linear de materiais que variam sua não homogeneidade quando são submetidos a um campo acústico. O estudo é baseado na teoria de análise espectral de ecos de ultra-som para entender o processo físico de interação da onda - emulsão. A emulsão bifásica que tem sido analisada neste estudo é composta principlamente por um óleo mineral A e um óleo vegetal B. A metodologia é baseada na análise tempo freqüência de ecos e sinais de backscattering de ultra-som com uma freqüência central de 5 MHz e uma largura de banda de 8 MHz @ - 3dB. A velocidade média de propagação acústica para a mistura liquida foi estimada em 1354 m/s. O coeficiente de atenuação foi calculado para cada fase separada e se obtiveram os seguintes resultados: 0.82 dB/cm - MHz para o óleo A e 0.59 dB/cm - MHz para o óleo B. O parâmetro B/A avaliado para cada fase separada foi de: 8.43 para óleo A e 10.74 para o óleo B. A variação dos parâmetros acústicos descreveram a evolução da emulsão no tempo mediante o decremento das curvas de atenuação, B/A e IBC. A velocidade de propagação não forneceu informações relevantes a respeito do processo de separação das fases, devido a sua variação mínima. A percentagem média de variação dos parâmetros acústicos durante o processo dinâmico de separação das fases da emulsão foi de 1.39% para a velocidade de propagação, 46.9 para B e 51% para B/A. Espera-se que o estudo possa ser extrapolado para o melhor entendimento da interação de ondas de ultra-som em meios não homogêneos e variantes no tempo. / This research studies the time evolution of acoustic propagation parameters of a mixture of inmiscible liquids considerated as unstable emulsion during the separation process into its original phases. The main aspect of this work is to deal with the behavior of nonlinear, nonhomogeneous and time-varying media when they are submitted in an acoustic field. The study is based on spectral analysis theory of ultrasound-backscattered echoes for understanding of physical process of the wave-emulsion interaction. The biphasic emulsion, which has been analyzed during this study, is composed by a mineral oil (phase A) and vegetable oil (phase B). The methodology was based on time-frequency analysis of backscattered broadband ultrasound echo at center frequency of 5 MHz and bandwidth of 8 MHz @ -3dB using an ultrasound system in pulse-echo mode. The mean acoustic propagation velocity for the mixture liquid was estimated in 1354 m/s. The attenuation coefficients were calculated for each separated phase resulting in 0.82 dB/cm-MHz to phase A and 0.59 dB/cm-MHz to phase B. The B/A parameter have been evaluated resulting in 8.43 (phase A) and 10.74 (phase B). The acoustic parameters variation allowed identified different emulsification state inside emulsion. The time evolution for the emulsion was described throught the decrease of attenuation, B/A and IBC. The acoustic propagation velocity don\'t provide relevant information about the phases separation process, because it showed a minimal variation. The mean percentage variation for the time evolution of the acoustic parameters was 1.39% to the acoustic propagation velocity, 46.9% to B and 51% to B/A. We hope that observations can be extrapolated aiming a better understanding of ultrasonic waves interaction in non-homogeneous time-varying medium.
384

Efeitos renais da exposição crônica a nicotina em camundongos com deficiência de Klotho / Renal effects of chronic nicotine exposure in klotho deficient mice

Coelho, Fernanda Oliveira 19 August 2015 (has links)
A nicotina é o principal componente do tabaco e dos cigarros eletrônicos. A exposição crônica a nicotina, em quantidades semelhantes às atingidas pelo tabagismo humano, é responsável por piora da lesão renal aguda e da doença renal crônica. O gene klotho, predominantemente expresso no rim, foi descoberto após uma mutação insercional, com o surgimento de um fenótipo semelhante ao envelhecimento humano nos camundongos homozigotos para esse transgene. A proteína Klotho transmembrana tem ação de co-receptor do fator de crescimento fibroblástico 23 (FGF-23) e sua forma secretada atua em diversas vias intracelulares e em órgãos a distância. A deficiência de Klotho ocorre no envelhecimento, em situações que levam a lesão renal aguda e na doença renal crônica. A expressão reduzida de Klotho também agrava lesão renal aguda e participa da progressão da doença renal crônica, enquanto o seu aumento, ou a sua reposição, protegem dos processos inflamatórios e do estresse oxidativo. Neste estudo, objetivamos avaliar os efeitos renais, hemodinâmicos e sobre a expressão de Klotho da exposição crônica a nicotina e quais os efeitos dessa exposição nos animais haploinsuficientes para o transgene klotho (Kl+/-). Utilizamos para estas avaliações camundongos Kl+/- e seus controles wild type (Kl+/+), que foram expostos a nicotina (200 mcg/mL) ou veículo (sacarina 2%) diluídos em água por 28 dias. Ao final do estudo foram avaliados diurese, eletrólitos plasmáticos e urinários, ureia, aldosterona, ADH, FGF-23 e PTH intactos plasmáticos, expressão protéica renal de Klotho, alfa7-nAchR, NHE3, ENaC, NKCC2, AQP2, e-NOS, VEGF, MnSOD e renina, expressão genica renal de klotho, interleucinas, TBARS e GSH em tecido renal, taxa de filtração glomerular por FITC-inulina, pressão arterial e frequência cardíaca invasivas, sensibilidade baroreflexa e modulação autonômica cardíaca e periférica por análise espectral. Após a exposição a nicotina, os animais Kl+/+ apresentaram redução da expressão renal da proteína e do RNAm de Klotho e uma tendência a aumento dos níveis plasmáticos de FGF-23, associados a uma queda da diurese e da taxa de filtração glomerular, sem alteração dos níveis de ADH. Esses animais Kl+/+ também apresentaram aumento da sensibilidade barorreflexa em resposta ao nitroprussiato e um predomínio da modulação simpática cardíaca, com redução da expressão renal dos alfa7-nAchR. Os animais Kl+/- tiveram níveis renais ainda menores de Klotho após a exposição a nicotina, com aumento de TBARS, IL-6, uréia e aldosterona em relação aos Kl+/- não expostos. A diurese, a taxa de filtração glomerular e a expressão dos alfa7-nAchR não se reduziram e não houve aumento da sensibilidade barorreflexa após exposição a nicotina, com um predomínio da modulação parassimpática cardíaca, nesses animais Kl+/-. A ingesta hídrica, a pressão arterial e a frequência cardíaca foram semelhantes entre os 4 grupos. A proteinúria foi maior nos animais Kl+/- do que nos animais Kl+/+ após a exposição a nicotina. Podemos concluir que a exposição crônica à nicotina reduz a expressão renal de Klotho, estimula vias de inflamação, fibrose e estresse oxidativo renais e tem efeitos renais e sistêmicos diferentes de acordo com os níveis basais de Klotho / Nicotine is a major compound of tobacco and electronic cigarettes. Chronic exposure to nicotine concentrations that are similar to human smoke worsens acute kidney injury and chronic kidney disease. The klotho (Kl) gene is expressed predominantly by the kidney and was discovered after an unintentional insertional mutation that resulted, in transgenic homozygous mice, in a phenotype similar to human aging. Klotho transmembrane protein acts as a co-receptor to fibroblastic growth factor 23 (FGF-23) and the secreted form interacts in multiple intracellular pathways, with effects in distant organs. Klotho deficiency occurs in aging and in multiple acute kidney injury and chronic kidney disease etiologies, whereas klotho upregulation and replacement protect from inflammation and oxidative stress. Here, we investigated renal and hemodynamic effects of chronic nicotine exposure, its effects over renal expression of Kl, and compared wild type (Kl+/+) and Kl haploinsufficient mice (Kl+/-) in terms of the effects of that exposure. Kl+/- and Kl+/+ mice received nicotine (200 ?g/ml) or vehicle (saccharine 2%) in drinking water for 28 days. We evaluated diuresis, ions in serum and urine, urea, plasma and urinary levels of cotinine, aldosterone, plasma antidiuretic and parathyroid hormone, plasma FGF-23, protein expression of (immunoblotting for) Klotho and ?7 nicotinic acetylcholine receptor, NHE3, NKCC2, ENaC, aquaporin-2, e-NOS, VEGF and renin, klotho mRNA, kidney interleukines, TBARS and GSH, glomerular filtration rate by fluorescein isothiocyanate-inulin clearance, mean arterial pressure, heart rate, baroreflex sensitivity and autonomic cardiac and peripheral modulation by spectral analysis. After nicotine exposure, Kl+/+ mice showed decreased Klotho protein and mRNA and a tendency towards an elevation in plasma FGF-23, which were associated with both diuresis and glomerular filtration rate reductions, without modifications in ADH levels. Besides that, Kl+/+ animals increased baroreflex sensitivity after nitroprusside, a predominant sympathetic cardiac modulation and lower alfa7-nAchR kidney expression. Kl+/- mice reduced even more Klotho renal expression, with higher levels of TBARS, IL-6, urea and aldosterone. Diuresis, glomerular filtration rate, alfa7-nAchR expression and baroreflex sensitivity were the same of their controls. Cardiac parasympathetic modulation predominated in Kl+/- mice. Fluid intake, mean arterial pressure and heart rate were similar across the 4 groups. Renal protein excretion was higher in Kl+/- than in their controls after nicotine exposure. We can conclude that chronic nicotine exposure downregulates Klotho kidney expression induces inflammation and oxidative stress and stimulates fibrosis, with different renal and systemic responses according to basal Klotho levels
385

"Investigações sobre o controle neuromotor do músculo reto do abdome" / INVESTIGATIONS ABOUT THE NEUROMOTOR CONTROL OF THE RECTUS ABDOMINIS MUSCLE

Marchetti, Paulo Henrique 11 March 2005 (has links)
O músculo reto do abdome é um importante músculo da parede abdominal, responsável pela estabilização e função da coluna, tanto em atividades atléticas quanto em atividades cotidianas. Entretanto, pouco se conhece sobre o controle neuromotor de tal estrutura em atividades voluntárias, como os exercícios abdominais, e como as diferentes tarefas agem na ativação segmentada das porções musculares do músculo reto do abdome. Em geral, a presente dissertação teve como objetivo investigar o controle neuromotor do músculo reto do abdome em diferentes tarefas voluntárias através de quatro experimentos. O primeiro experimento teve como objetivo descrever as características morfológicas do músculo reto do abdome, em particular sua área de secção transversa, ao longo do comprimento longitudinal do músculo, utilizando as imagens do projeto homem visível (NLM). O segundo experimento objetivou o mapeamento dos pontos motores para cada porção muscular. O terceiro experimento investigou o controle neuromotor das diversas porções musculares em tarefas isométricas de baixa intensidade. E por fim, o quarto experimento investigou o comportamento das porções musculares em diferentes tarefas isométricas em condição de fadiga neuromuscular. Baseado nos experimentos apresentados neste estudo pode-se concluir que o músculo reto do abdome é uma estrutura extremamente complexa em sua arquitetura, sendo caracterizada por diversas porções musculares que se interconectam através de aponeuroses tendíneas, onde, possivelmente nenhuma fibra muscular atravesse seus ventres. Devido a tal consideração, supõe-se que o controle das diversas porções, por sua independência anatômica, dependa de um aporte nervoso diferenciado para o controle motor. Assim, podem-se definir pelo menos um nervo para cada porção em ambos os ventres. Devido a tais considerações, se torna plausível considerar um controle neuromotor diferenciado de cada porção muscular, mas os experimentos relacionados à ativação muscular de baixa intensidade mostram um controle central compartilhado por todos os ventres e um ganho associado à tarefa para cada porção de forma distinta. Os resultados do experimento de indução de fadiga demonstraram diferenças no espectro, mostrando diferenças no controle neuromuscular em função das tarefas, mas não apresentou diferenças na análise temporal. Conclui-se, então, que existe uma ativação seletiva para cada porção muscular, embora não se consiga ativar apenas uma região do ventre muscular, em função do controle central associado. Deste modo, parece que a alteração da tarefa possui valor na alteração da ênfase para cada porção muscular, mas questiona-se o valor deste ganho para objetivos relacionados à força ou hipertrofia muscular. / The rectus abdominis is an important muscle of the abdominal wall; it is responsible for the stabilization and function of the spine, as to athletic activity as daily activity. However, we do not have enough knowledge about the neuromotor control of this structure in voluntary activities, like abdominal exercises and how different tasks alter the segmental activation of the different parts of the abdomen. The aims of the present dissertation were to investigate the neuromotor control of the rectus abdominis in different voluntary tasks by four experiments. The aim of the first experiment was to describe morphologic characteristics of the rectus abdominis, in particular its transverse cross section, using the visible human project (NLM). The aim of the second experiment was to define motor points to each portion of the rectus abdominis. The aim of the third experiment was to investigate the neuromotor control of the each portion of the rectus abdominis in isometric low intensity tasks. And, the fourth experiment investigated the behavior of the different portions of the rectus abdominis in different isometric tasks on neuromuscular fatigue. The present experiments showed that the rectus abdominis muscle has an extremely complex structure in its architecture, defined by different portions without connection one each other and it is defined by a lot of portions that connect by tendinius aponeuroses. It could be considered that the control of the different portions, by your anatomic characteristics, have different nerves to each portion that facilitates the motor control. We found at least one nerve to each portion. But it is possible that exist different neuromotor control to each portion, so the next experiments related to low intensity of the muscular activation showed a central control shared by all portions and the gain associated to each task. The result of the fatigue experiment showed differences on spectral analysis and changes in neuromuscular control by the tasks, but did not present differences on temporal analysis. In conclusion, there is selective activation to each muscular portion; however, it could not be activated only one portion of the rectus abdominis to a specific task. Therefore, it can be that the alteration of the task has an important value on each muscular portion, but it does not know if this gain has any value to strength and hypertrophy.
386

Análise da resistência a corrosão do aço carbono revestido com Al55-Zn após deformação mecânica e tratamento térmico

BESERRA, Antonio Adelmo Freire 12 January 2001 (has links)
Submitted by Edisangela Bastos (edisangela@ufpa.br) on 2018-03-28T17:05:06Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_AnaliseResistenciaCorrosao.pdf: 6473132 bytes, checksum: 4a83f2ee43a0dcb1257ada308b39c480 (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2018-04-02T15:15:36Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_AnaliseResistenciaCorrosao.pdf: 6473132 bytes, checksum: 4a83f2ee43a0dcb1257ada308b39c480 (MD5) / Made available in DSpace on 2018-04-02T15:15:36Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_AnaliseResistenciaCorrosao.pdf: 6473132 bytes, checksum: 4a83f2ee43a0dcb1257ada308b39c480 (MD5) Previous issue date: 2001-01-12 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O revestimento de Al55-Zn apresenta uma resistência à corrosão atmosférica em média doze vezes superior à do revestimento galvanizado. Entretanto, após deformação mecânica, o revestimento de Al55-Zn apresenta microtrincas que comprometem a sua resistência à corrosão. Neste trabalho estudou-se a variação na resistência à corrosão do revestimento de Al55-Zn após deformação sob tração ou dobramento e a influência de tratamentos térmicos a '200 GRAUS' e a '360 GRAUS' durante 16h na resistência à corrosão do revestimento antes e depois das deformações. Para isso, um grupo de amostras do material foi deformado sob tensão de tração até 10% ou 15% de seu comprimento inicial e outro grupo foi dobrado até '90 GRAUS' ou '180 GRAUS'. A variação na resistência à corrosão do revestimento foi analisada através das técnicas de extrapolação de Tafel e de espectroscopia de impedância eletroquímica. Como resultado, observou-se que tanto a deformação axial quanto o dobramento do material reduzem a sua resistência à corrosão. Após o tratamento térmico a '360 GRAUS' as amostras deformadas até 10% ou 15% recuperaram a sua resistência à corrosão, entretanto, as amostras dobradas até '90 GRAUS' ou '180 GRAUS' apresentaram apenas uma recuperação parcial na sua resistência à corrosão após os tratamentos térmicos. / Analysis of the corrosion resistance of the 55AI-Zn coating on carbon steel after mechanical deformation and heat treatment The atmospheric corrosion resistance of 55%Al-Zn alloy coating on average is twelve times that of an equal thickness of galvanized coating. However, it has been shown that microcracks were observed at all levels of strain under simple uniaxial tension. Our research has been focused on determining the degree of corrosion experienced by these coatings after deformation under simple tension or bending and how much the heat treatment at '200 DEGREES' or '360 DEGREES' for 16h can influence the corrosion resistance of the coating. The coated sheet samples were strained to 10% or 15% engineering strain while another group of samples was bent to bend angles of '90 DEGREES' or '180 DEGREES'. The corrosion resistance of the samples was evaluated trhough Tafel extrapolation and electrochemical impedance spectroscopy methods. As a result, it was observed that both the straining and the bending of the coating reduces its corrosion resistance. After the heat treatment at '360 DEGREES' the samples strained to 10% or 15% recover their corrosion resistance, but the specimens bended to '90 DEGREES' or '180 DEGREES' recuperate only partially the corrosion resistance after the heat treatments.
387

AVALIAÇÃO DA ESTABILIDADE DE COR DE LAMINADOS CERÂMICOS APÓS CIMENTAÇÃO ADESIVA / Evaluation of color stability of ceramic veneers after adhesive cementation

Sakamoto Junior, Antonio Setsuo 22 December 2015 (has links)
Made available in DSpace on 2017-07-24T19:21:58Z (GMT). No. of bitstreams: 1 Antonio Setsuo Sakamoto Junior.pdf: 2373735 bytes, checksum: b35b9e1a804cb1e6e80c6137dada9016 (MD5) Previous issue date: 2015-12-22 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Thin ceramic laminates have been widely requested by patients because it’s a reliable conservative aesthetic procedure, stable and presents adequate longevity. It is known that the color change of the cement below these thin restorations may result inappropriate final color. Thus, the purpose of this in vitro study was to evaluate the color agreement between pressable lithium disilicate ceramics with tryin pastes and corresponding resin cements, determination of the degree of conversion of resin cements using FT-Raman spectroscopic and color stability after artificial accelerated aging (AAA) for 300 hours. Eighty-four ceramic discs (0.3 mm, 0.5 mm, 1.0 mm thick) were prepared (IPS e.maxPress HT A2 – Ivoclar Vivadent) to simulate veneers. Evaluation the baseline color was done in the CIE-L*a*b* color space with reflectance spectrophotometer (control group). The try-in pastes were applied into the interlayer of the ceramic (simulation of selection color procedure) above silicon transparent matrix (0.1 mm thick) and the color complex were measured using a spectrophotometer (n=7), with no substrate. The same ceramic discs were used for cementation procedure with Variolink II (only base),after storage in distilled water, protected from light, at 37ºC for 24 hours, the specimens were mensured the color and submitted to FT-Raman spectroscopy to determinate the degree of conversion (DC). After that, the specimens were AAA for 300 hours and measured by spectrophotometer to calculate ΔE. Two-way ANOVA was used to analyze the data. Tukey’s post hoc for multiple comparisons and Spearman correlation test were performed (α = 0.05). There was no agreement between the try-in with resin cements, L* and b* values increased, increasing the value/opacity,yellowish of the complex. All groups exhibited values of ΔE>3.3, except resin color A3 group (1.0 mm ceramic thickness). Ceramic thicknesses (0.3 mm and 0.5 mm) did not affect the DC compared to the control (p> 0.05). Thus, DC was influenced by the color of cement, where the over saturated color showed higher conversion rate, DC decreased when ceramic disc thickness increased. No correlation between DC and ΔE was observed. / A modalidade indireta de restauração denominada laminado cerâmico, vem sendo vastamente solicitada pelos pacientes, por se tratar de um procedimento confiável, estável, conservador, estético e apresenta longevidade aceitável. Sabe-se que a alteração de cor do cimento localizado abaixo destas restaurações delgadas pode influenciar negativamente no aspecto estético final. Desta forma, o propósito do presente estudo in vitro foi avaliar a concordância da coloração da pasta de prova e seu respectivo cimento resinoso, verificar o grau de conversão deste pelo método Micro-Raman e sua estabilidade de cor após envelhecimento artificial acelerado (EAA) por 300 horas. Foram confeccionados 84 discos cerâmicos com sistema IPS e.maxPress HT (Ivoclar Vivadent) na cor A2 com 3 espessuras (0.3 mm, 0.5 mm, 1.0 mm) cuja coloração foi mensurada com espectrofotometria de refletância (grupo controle). Em seguida, foi realizada a simulação da seleção da cor do cimento Variolink II (try in Transparente, Opaco, A3) e mensurada a cor do conjunto nas coordenadas CIEL* a*b*. Depois foi realizada a cimentação adesiva (mesmos discos cerâmicos utilizados com try in) com três cores de cimentos resinosos (Base: Transparente, Opaco, A3), sobre uma matriz de silicone transparente com cavidade de espessura de 0,1 mm (n=7), sem qualquer substrato. Após armazenamento com água destilada, protegido da luz, em estufa a 37ºC por 24h, os corpos de prova (cp) foram submetidos novamente ao teste de espectrofotometria e ao teste grau de conversão (GC) pelo método FT-Raman. Em seguida, foram submetidos ao EAA por 300 horas e mensurada a coloração para verificar se houve alteração (ΔE). Os dados coletados foram submetidos à ANOVA 2 fatores, seguido pelo pós-teste de Tukey e pelo teste de correlação de Spearman (α=0,05). Não houve concordância entre o try in e respectivo cimento, os valores de L* e b* aumentaram, tornando mais luminosa/opaca e amarelada. Todos grupos apresentaram valores superiores de ΔE=3,3, exceto o grupo do cimento cor A3 (cerâmica espessura de 1,0 mm) e as espessuras cerâmicas de 0,3 e 0,5 mm não influenciaram o GC, onde apresentaram valores sem diferença significativa (p>0,05) comparada ao grupo controle. Assim, o GC foi influenciado pela cor do cimento, onde o mais saturado apresentou maior taxa de conversão, ao passo que o valor de GC diminuiu quando a espessura do disco cerâmico interposto aumentou. Não houve relação entre o GC e ΔE.
388

ALTERNATIVAS PARA MELHORAR AS PROPRIEDADES ADESIVAS DE SISTEMAS ADESIVOS UNIVERSAIS EM DENTINA EROSIONADA / Alternatives to improve the adhesive properties of universal adhesive systems in eroded dentin

Siqueira, Fabiana Suelen Figueredo de 07 April 2017 (has links)
Made available in DSpace on 2017-07-24T19:22:05Z (GMT). No. of bitstreams: 1 FABIANA SIQUEIRA.pdf: 4384235 bytes, checksum: 655ceab1a73a43f410cdb4b5e3773475 (MD5) Previous issue date: 2017-04-07 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The aim of the present study was evaluate the adhesive properties of eroded dentin with different pH cycling using universal adhesive systems and to evaluate the application of collagen cross-linking agent or MMP inhibitors on the resin-eroded dentin interface, through of three in vitro studies. For the experiment 1, the teeth were randomly assigned into the experimental groups according to the combination of variables: dentin surface (sound dentin and eroded dentin) vs adhesive systems (10 universal adhesives) vs Adhesive strategy [etch-and-rinse (ER) and self-etch (SE)]. The adhesive systems were applied according to the manufacturer's instructions and the teeth were restored. They were sectioned to analysis of microtensile bond strength (μTBS) and nanoleakage (NL). The surfaces of 2 tooth were examined under scanning electron microscopy (SEM) to evaluate the surface characterization after erosive-cycling. For experiment 2, the teeth were randomly assigned into 18 experimental conditions according to the variables: Erosive cycling (eroded dentin with soft drink pH ≈ 2,7 and eroded dentin with citric acid pH 2.3) vs. adhesive systems [Prime & Bond Elect (PBE); Scotchbond Universal Adhesive (SBU); Tetric N-Bond Universal (TEU)] vs Treatment agents [6.5% primer containing proanthocyanidin (PA) and 0.1% riboflavin (RI)]. The surface was treated with primers and the adhesive systems were applied and restored. The samples were sectioned and tested for μTBS, NL and degree of conversion (DC). The surfaces of 2 tooth were examined under SEM to evaluate the surface characterization after erosive-cycling. For experiment 3, the teeth were randomly assigned into 18 experimental conditions according to the variables: Erosive cycling (eroded dentin with soft drink pH ≈ 2,7 and eroded eroded with citric acid pH 2.3) vs. Adhesive Systems (PBE; SBU; TEU) vs Acid pretreatment [control with 37% phosphoric acid;Phosphoric acid containing 2% chlorhexidine (CHXacid) and phosphoric acid containing 3% PA (PAacid)]. The teeth were acid-etched according to each experimental conditions, the adhesive systems were applied and the teeth were restored. The teeth were sectioned and tested for μTBS, NL and DC. Data were submitted to appropriate statistical analysis (α = 0.05). The μTBS values in eroded dentin were statistically lower than sound dentin, independent of the adhesive strategy (p < 0.01) The inclusion of primers containing collagen cross-linking agents in the eroded dentin adhesive protocol improved μTBS values (p <0.001),significantly reduced NL (p <0.004) for all the adhesives tested, as well as improved DC (p <0.03). The use of phosphoric acids containing MMPs inhibitors or collagen cross-linking agent improved μTBS values (p> 0.33), produced a significant reduction of NL (p <0.004) and improved DC (p <0.03). The application of MMP inhibitors (primer or acid etching - containing) were effective to improve the properties of the resin-eroded dentin interface. / O objetivo desse estudo foi avaliar as propriedades adesivas à dentina erosionada utilizando sistemas adesivos universais e verificar o efeito da aplicação de agentes reticuladores de colágeno ou inibidores de Metaloproteinases (MMPs) na interface resina-dentina erosionada, através de três estudos laboratoriais. Para o experimento 1, os dentes foram distribuídos aleatoriamente entre os grupos experimentais de acordo com a combinação das variáveis: superfície dentinária (controle sem erosão e erosionada) vs. sistemas adesivos (10 sistemas adesivos universais) vs.estratégia adesiva [condicionamento convencional (ER) e autocondicionante (SE)].Os sistemas adesivos foram aplicados de acordo com as especificações do fabricante e os dentes foram restaurados. Depois foram seccionados para análise da resistência de união à dentina (μTBS) e nanoinfiltração (NI). A superfície de 2 dentes foi examinada sob microscopia eletrônica de varredura (MEV) para avaliar as características da superfície após ciclagem erosiva. Para o experimento 2, os dentes foram aleatoriamente alocados em 18 condições experimentais de acordo com as variáveis: Ciclagem erosiva (dentina erosionada com coca-cola pH ≈ 2,7 e dentina erosionada com ácido cítrico pH 2,3) vs. Sistemas adesivos [Prime & Bond Elect (PBE), Scotchbond Universal Adhesive (SBU) e Tetric N-Bond Universal (TEU)] vs. Agentes de tratamento [primer contendo 6,5% de roantocianidina (PA) e primer contendo 0,1% de riboflavina (RI)]. Os sistemas adesivos foram aplicados de acordo com as especificações do fabricante após aplicação do primer e restaurados. A seguir, os dentes foram seccionados e testados para análise da μTBS, NI e grau de conversão (GC). A superfície de 2 dentes foi examinada sob MEV para avaliar as características da superfície após erosão. Para o experimento 3, os dentes foram alocados aleatoriamente dentro de 18 condições experimentais de acordo com as variáveis: Ciclagem erosiva (dentina erosionada com coca-cola pH ≈ 2,7 e dentina erosionada com ácido cítrico pH 2,3) vs. Sistemas adesivos (PBE, SBU e TEU) vs. pré-tratamento ácido [controle com ácido fosfórico 37%; Ácido fosfórico contendo 2% de clorexidina (CHXacido) e ácido fosfórico contendo 3% de PA (PAacido)]. Os dentes foram condicionados de acordo com cada grupo experimental, os sistemas adesivos foram aplicados e restaurados com resina composta. Posteriormente, os dentes foram seccionados e testados para análise da μTBS, NI e GC. Todos os dados foram submetidos a ANOVA 3 fatores e teste de Tukey (α = 0,05). Os valores de μTBS em dentina erosionada foi estatisticamente inferior à dentina sadia,independente da estratégia adesiva (p > 0,61). A inclusão de primers contendo agentes reticuladores de colágeno no protocolo adesivo a dentina erosionada,melhorou os valores de μTBS (p < 0,001), diminuiu significativamente a NI (p <0,004) para os adesivos testados, além de melhorar o GC (p < 0,03). A utilização de ácidos fosfórico contendo inibidores de MMPs ou agentes reticuladores de colágeno melhorou os valores de μTBS (p > 0,33), produziu uma redução significativa da NI (p < 0,004) e melhorou o GC (p < 0,03). Os agentes reticuladores independente do veículo (primer ou condicionamento ácido) foram eficazes para melhorar as propriedades da interface resina-dentina erosionada.
389

Magnetoestratigrafia e análise espectral de ritmitos permocarboníferos da Bacia do Paraná: influências dos ciclos orbitais no regime deposicional / Magnetostratigraphy and spectral analysis of Permian-Carboniferous rhythmites from Paraná Basin: orbital cycles influence on the depositional regime

Franco, Daniel Ribeiro 06 June 2007 (has links)
Este trabalho teve por objetivo investigar a escala temporal envolvida na deposição de ritmitos permocarboníferos da Bacia do Paraná (Subgrupo Itararé), expostos no Parque do Varvito (Itu, SP) e pedreira Itaú (Trombudo Central, SC), através de dados paleomagnéticos e de anisotropia de suscetibilidade magnética. Os estudos paleomagnéticos revelaram componentes de magnetização estável para ambas as coleções, com indicações de que a magnetização remanente é devida a portadores magnéticos (principalmente magnetita e hematita) de origem detrítica. A componente de magnetização característica, em ambos os casos, é de polaridade reversa, e foi identificada nos dois portadores magnéticos principais. A investigação da mineralogia magnética foi feita através de várias técnicas, incluindo espectroscopia Mossbauer, curvas termomagnéticas, curvas de histerese e ZFC/FC, além de microscopia ótica e eletrônica. Os dados paleomagnéticos e de anisotropia de susceptibilidade magnética permitiram a composição de séries temporais, que foram submetidas a análise espectral por transformada de Fourier de Lomb-Scargle para séries desigualmente espaçadas. Os espectros de potência resultantes foram posteriormente comparados com os espectros de séries de espessura individual das unidades litológicas, o que possibilitou a investigação de sinais harmônicos, sobre a qual foram propostas inferências a respeito das escalas temporais de sedimentação. Esta etapa do trabalho revelou escalas milenares para o domínio do tempo nos espectros de potência, indicando o registro dos ciclos orbitais de Milankovitch, bem como quase-periodicidades associadas à variabilidade solar e feedback do sistema oceânico-atmosférico, para todas as análises. Este conjunto de dados sugere o caráter não-anual de deposição dos ritmitos, ao contrário do proposto por alguns autores. O pólo paleomagnético calculado para a seção de Rio do Sul é compatível com o pólo do Permocarbonífero para a Bacia Sanfranciscana (MG), indicando que o intervalo de tempo envolvido na deposição dos sedimentos é suficientemente longo para eliminar os efeitos da variação secular do campo geomagnético. Alguns resultados adicionais desta tese proveram informações especiais: (i) Foram observados ciclos de indução solar (ciclos de Hallstattzein e de Suess) e a sugestão de ciclo compatível com o ciclo glacial-interglacial de Bond, recentemente sugerido como de origem solar, o que apontaria para uma possível feição harmônica, dominante sobre o sistema oceânico-atmosférico, e que poderia operar sobre períodos geológicos mais antigos; (ii) registro da remanência magnética possivelmente controlado por fatores mecânicos na sucessão de Itu, provavelmente relacionados a correntes de turbidez; (iii) indícios da presença de magnetossomas possivelmente rompidas e/ou oxidadas, em especial para a sucessão de Itu. / This work aims to investigate the timescale of the sedimentation of Permocarboniferous rhythmites from Paraná Basin (Itararé Subgroup) cropping out at the Parque do Varvito, (Itu, SP), and at the Itaú quarry, (Trombudo Central, SC) by means of paleomagnetic and anisotropy of magnetic susceptibility (ASM). The paleomagnetic study revealed stable magnetization components for both sections, which are carried by magnetic carriers (mainly magnetite and hematite) of detritic origin. The characteristic magnetization direction for each section is of reverse polarity and is found in both magnetite and hematite. Several techniques were used in the investigation the magnetic mineralogy including Mossbauer spectrometry, thermomagnetic curves, hysteresis and ZFC/FC curves, optical and electronic microscopy. Although not confirmed, some data pointed to the possibility of magnetic biomineralization with disrupted or oxidized mineral chains. The paleomagnetic and ASM data allowed the construction of time series that were submitted to spectral analysis by the Lomb-Scargle Fourier transform for unevenly spaced series. The resulting power spectra were then compared with the thickness spectrum. Based on the harmonic signals identified in all time series it was possible to infer deposition rates for both Itú and Itaú rhythmites. This procedure pointed to millennial timescale, and periodical signal compatible to Milankovitch orbital forcing, as well quasi-periodicities related to solar variability and feedback of ocean-atmospheric system, were identified in both sections. Such evidences strongly point to the non-annual sedimentation character, in opposition to previous hypothesis. The paleomagnetic data from the Rio do Sul rocks allowed the calculation of a paleomagnetic pole which is in agreement to the one recently obtained for the Santa Fé Group, Sanfranciscana Basin (MG), indicating that the time interval comprised by the Rio do Sul rhythmites is long enough for eliminating the secular variation effects. Results from this work provide also indications for the record of (i) solar forcing cycles (Hallstattzein and Suess cycles); (ii) spectral peak values of 1,5-ky and 6,0 - 8,0 ky cycle, which is compatible to the glacial-interglacial Bond cycle observed in Quaternary geological records. Such result would extend to ancient times the atmosphere-ocean interaction pattern.
390

Avaliação da q-transformada de Fourier como ferramenta não linear de estudos de sinais biomédicos / Assessment of the q-Fourier transform as nonlinear tool for biomedical signals studies

Juliano Jinzenji Duque 14 December 2012 (has links)
A análise de sinais biomédicos é uma área de pesquisa importante pois diversos processos fisiológicos que ocorrem no corpo humano podem ter suas atividades registradas como sinais. Neste trabalho, investigou-se a q-transformada de Fourier (q-FT), uma generalização não linear da transformada de Fourier baseada no formalismo não extensivo de Tsallis, que é caracterizado pela presença do parâmetro q. Foram realizados estudos analíticos e experimentos computacionais com sinais reais e simulados. A partir da dfinição da q-FT, um método de análise espectral generalizado para aplicação em sinais biomédicos foi desenvolvido. Este método foi avaliado através de experimentos com séries de intervalos RR cardíacos, usadas em estudos de variabilidade da frequência cardíaca. Os resultados ajudam a esclarecer algumas propriedades desta q-transformada, porém não indicam que o método desenvolvido seja efetivo para a análise espectral de séries RR. Entretanto, estudos posteriores de novos métodos de análise espectral baseados no formalismo de Tsallis podem ser desenvolvidos para a investigação de sinais biomédicos. / Biomedical signals analysis is an important research eld because many physiological processes occurring in human body can have their activities recorded as signals.This study investigated the q-Fourier transform (q-FT), a nonlinear generalization of Fourier transform based on the Tsallis nonextensive formalism, which is characterized by q parameter. Analytical studies and computational experiments with simulated and real signals were conducted. From the denition of q-FT, a generalized spectral analysis method for application in biomedical signals has been developed. This method was assessed through experiments with cardiac RR interval time series, which are used in studies of heart rate variability. The results help to clarify some properties of the q-Fourier transform, but do not indicate that the developed method is efective for the spectral analysis of RR series. However, further studies on new spectral analysis methods based on Tsallis formalism can be developed for biomedical signals investigation.

Page generated in 0.0617 seconds