• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 15
  • 2
  • 1
  • Tagged with
  • 21
  • 11
  • 9
  • 9
  • 8
  • 8
  • 8
  • 8
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Difusão e relaxação anelástica devido ao hidrogênio em solução sólida em ligas de Nb-Ti e Nb-Zr. / Diffusion and anelastic relaxation due to hydrogen in solid solution in Nb-Ti and Nb-Zr alloys.

Carlos Roberto Grandini 14 May 1993 (has links)
Foi estudado o efeito do hidrogênio dissolvido intersticialmente em ligas de nióbio-titânio e nióbio-zircônio. Nas ligas de nióbio-titânio, foram efetuadas medidas de decremento logarítmico por intermédio de medidas de atrito interno em um pêndulo de torção oscilando com freqüência em torno de 4.0 Hz, para amostras puras e dopadas com hidrogênio. Os resultados mostraram a interação do hidrogênio com a matriz metálica através do Efeito Gorsky. Nas ligas de nióbio-zircônio, foram efetuadas medidas de atenuação ultra-sônica para freqüências de 10 e 30 MHz, em amostras puras, contendo hidrogênio e contendo oxigênio e hidrogênio. Os resultados mostraram a interação do hidrogênio com a matriz metálica através de um processo de reorientação induzida por tensão de átomos de hidrogênio localizados em sítios intersticiais tetraedrais em torno de átomos de oxigênio congelados em sítios intersticiais octaedrais, próximos de átomos de nióbio da matriz metálica. / We study the effect of hydrogen dissolved interstitially in niobium-titanium and niobium-zirconium alloys. In the niobimn-titanium alloys, the logarithmic decrement was studied by internal friction measurements in a torsion pendulum with frequency about 4.0 Hz, on pure and hydrogen doped samples. Our results showed the interaction of hydrogen with the metallic matrix by the Gorsky effect. In the niobium-zirconium alloys, the ultrasonic attenuation was measured by the echo-pulse method with frequencies of 10 and 30 MHz, for pure, doped with hydrogen and doped with oxygen and hydrogen. The results have shown the interaction of hydrogen with the metallic matrix by a stress induced ordering of hydrogen atoms localized at tetrahedral sites around frozen oxygen atoms localized in the octahedral sites near the niobium atoms in the metallic matrix.
12

Principles of the draw-bend springback test

Wang, Jianfeng 30 March 2004 (has links)
No description available.
13

Principles of the draw-bend springback

Jianfeng, Wang 18 June 2004 (has links)
No description available.
14

Surface wave propagation in 3-D anelastic media

Ruan, Youyi 24 October 2012 (has links)
Lateral perturbations in anelasticity (Q) and wave speed together provide important constraints on thermal and chemical structures in the mantle. In present-day tomography studies of global wave speed and anelasticity, the significance of 3-D wave speed and 3-D Q structures on surface wave travel times and amplitudes has not been well understood. In this dissertation, the effects of lateral perturbations in anelasticity (Q) and wave speed on surface wave observables are quantified based upon wave propagation simulations in 3-D earth models using a Spectral Element Method. Comparison between phase delays caused by 3-D wave speed structures and those caused by 3-D Q variations show that anelastic dispersion due to lateral perturbation in Q is important in long-period surface wave and can account for 15-20% observed phase delays. For amplitude perturbations, elastic focusing/defocusing effects associated with 3-D wave speed structures are dominant while energy dissipation is important in short-period (~ 50 s) surface waves but decreases quickly with increasing wave period. Anelastic focusing/defocusing associated with 3-D anelastic dispersion becomes more important than wave attenuation in longer period surface waves. In tomography studies, ray theory breaks down and finite frequency effects become important when the length scale of heterogenities are smaller than seismic wavelength. Finite frequency effects in 3-D earth models are investigated by comparing theoretical predictions of travel times and amplitudes with "ground truth" measurements made on synthetic seismograms generated in SEM simulations. The comparisons show that finite frequency effects are stronger in amplitudes than in phases, especially at long periods. / Ph. D.
15

Efeito do oxigênio nas propriedades anelásticas da liga Ti-10Mo para aplicação biomédica /

Nogueira, Renata Abdallah. January 2008 (has links)
Orientador: Carlos Roberto Grandini / Banca: Sandra Giacomin Schnider / Banca: Eduardo Carlos Bianchi / O Programa de Pós-Graduação em Ciência e Tecnologia de Materiais, PosMat, tem caráter institucional e integra as atividades de pesquisa em materiais de diversos campi da Unesp / Resumo: A utilização de biomateriais do reparo do tecido ósseo tem revolucionado a Ortopedia e a Odontologia atuais. Um metal estudado para estas aplicações é o titânio e suas ligas, pois possuem um excelente grau de biocompatibilidade com o organismo humano, uma excelente resistência à corrosão em meio biológico e uma ótima relação resistência mecânica/densidade. Estas propriedades são fortemente influenciadas pela presença de lementos intersticiais e as medidas de atrito interno têm sido muito utilizadas para verificar o comportamento destes elementos em materiais. O objetivo neste trabalho foi estudar o efeito de elementos intersticiais nas propriedades da liga Ti-10Mo (% em peso), por meio de medidas de difração de raios X, microscopia eletrônica e varredura, testes de citotoxidade, corrosão e espectroscopia mecânica. As amostras foram submetidas a tratamentos térmicos de recozimento e dopagem com oxigênio. Os testes de biocompatibilidade mostraram que não houve nenhuma resposta indireta. Os extratos dos materiais não interferiram no desenvolvimento, crescimento e proliferação das células. Foi detectada uma melhora na taxa de corrosão, juntamente com um aumento do potencial de corrosão, com a dopagem do material, características estas interessantes para um biomaterial. Os resultados de espectroscopia mecânica mostraram a presença de uma estrutura de relaxação após a dopagem com oxigênio em torno de átomos dos elementos que compõem a liga. Observou-se que a adição de oxigênio intersticial causou um aumento no módulo de elasticidade, o que é ruim quando se trata de um biomaterial para implantes ortopédicos. / Abstract: The use of the biomaterials in the repair of the bone tissue has been revolutionizing the Orthopedics and the Odontology. A metal very studied for these applications is the titanium and its alloys, because they possess an excellent corrosion resistance in a biological media and a good relationship mechanical strength/density. These properties are strongly influenced by the presence of interstitial elements and the internal friction measurements have been a lot used to verify the behavior of these interstitial elements in materials. The objective of this work was to study the effect of interstitial elements in the properties of the Ti-10Mo (%in weight) alloy, through X-ray diffraction, scanning electron microscopy, cytotoxicity tests, corrosion and mechanical spectroscopy. The samples were submitted to heat treatments of annealing and oxygen doping. The biocompatibility tests showed that there was not any indirect cytotoxic answer. The extracts of the materials didn't interfere in the development, growth and proliferation of the cells. An increase in the corrosion rate was detected, with an increase of the corrosion potential, with the oxygen doping, interesting for applications as biomaterial. The mechanical spectroscopy results showed the presence of a relaxation structure after the oxygen doping that was attributed mainly to the stress-induced ordering of the oxygen atoms around the atoms that compose the alloy. It was observed an increase in the elasticity with the oxygen doping, what is bad when it is a biomaterial. / Mestre
16

Anelasticidade em titânio, tântalo e na liga Ti-40Ta

Patricio, Marco Antonio Tito 24 July 2014 (has links)
Made available in DSpace on 2016-06-02T20:16:53Z (GMT). No. of bitstreams: 1 5978.pdf: 11727715 bytes, checksum: 7ecd56710aed6f64b6e687a355a259bf (MD5) Previous issue date: 2014-07-24 / Financiadora de Estudos e Projetos / The growing demand for increasingly resistant and biocompatible with the human body implantable materials, has led to an increase in demand for new metallic biomaterials. Some materials, such as titanium and its alloys, especially the Ti-6Al-4V, are widely used in the manufacture of orthopedic implants due to their excellent biocompatibility, high corrosion resistance and low density. However, the characteristics of these materials are not considered optimal, mainly because they have a high value of the elastic modulus when compared to the human bone. Include, that in the last decade studies have revealed diseases associated with elements such as Al and V, present in the alloy Ti-6Al-4V. Thus, it have looked for alternatives to the alloys used as biomaterials, still having one common element titanium, but having no toxic elements such as 𝛽 type titanium alloys, formed by non-toxic elements such as Nb, Ta, Zr, Mo and Sn has shown that lower values of modulus, greater fatigue resistance and corrosion resistance, exhibiting excellent biocompatibility. Accordingly, the alloys formed by Ti-Ta become promising candidates as biomaterials, since it has been observed that the content of Ta affects the value of the elastic modulus. For some compositions of this alloy, lower modulus values of this alloys that are currently used in biomedical applications were observed. However, the alloys formed by Ti-Ta still have properties that have been little studied. Thereby, the objectives of this master s project consist in getting the alloy Ti-40Ta and its characterization by means of the technique of mechanical spectroscopy, as of its elements that compose the alloy. The technique of mechanical spectroscopy to be non-destructive, it is widely used for providing the anelastic spectrum (oscillation frequency and internal friction as a function of temperature) is considered sensitive to phase transitions and dynamic processes, which are essential for understanding the structural changes occurring in these materials. This study was determined the dynamic elastic modulus for the pure Ti and Ta elements, and the Ti-40Ta through flexural vibrations. The elastic modulus found for the alloy at room temperature was (71 ± 5) GPa, which is in accordance with results available in the literature. The value of modulus of the alloy is lower when compared to the commercial biomedical alloys and is closer to that of human bone, which makes the alloy Ti-40Ta a potential candidate to be used in biomedical applications. / A crescente demanda por materiais implantáveis cada vez mais resistentes e biocompatíveis com o organismo humano, tem levado a um aumento na procura por novos biomateriais metálicos. Alguns materiais, como o titânio e suas ligas, com destaque para a liga Ti-6Al-4V, são largamente utilizados na fabricação de implantes ortopédicos devido as suas excelentes características como biocompatibilidade, alta resistência à corrosão e baixa densidade. Entretanto, as características desses materiais ainda não são consideradas ideais, principalmente porque apresentam um alto valor do módulo de elasticidade quando comparado com o osso humano. Cabe mencionar, que na última década estudos revelaram doenças associadas a elementos como o Al e V, presentes na liga Ti-6Al-4V. Desta forma, busca-se alternativas às ligas empregadas como biomateriais, ainda contendo como elemento principal o titânio, mas que não possuam elementos tóxicos. Estudos recentes mostram que as ligas de titânio tipo 𝛽, formadas por elementos não tóxicos como Nb, Ta, Zr, Mo e Sn, tem apresentado valores mais baixos módulo de elasticidade, maior resistência à fadiga e maior resistência à corrosão, além de exibir uma excelente biocompatibilidade. Neste sentido, as ligas formadas por Ti-Ta tornaram-se candidatas promissoras como biomateriais, uma vez que, foi observado que o teor de Ta afeta o valor do módulo de elasticidade. Para algumas composições, desta liga, foram observados valores de módulo inferiores as ligas de Ti que atualmente são empregadas em aplicações biomédicas. No entanto, as ligas formadas por Ti-Ta ainda possuem propriedades pouco estudadas. Deste modo, os objetivos deste projeto de mestrado consistem na obtenção da liga Ti-40Ta e na sua caracterização por meio da técnica de espectroscopia mecânica, bem como a de cada elemento que compõem a liga. A técnica de espectroscopia mecânica, por ser não destrutiva, é amplamente usada por fornecer o espectro anelástico (frequência de oscilação e atrito interno em função da temperatura), sendo considerada sensível a transições de fase e a processos dinâmicos, que são essenciais para compreender as alterações estruturais que ocorrem nestes materiais. Neste estudo, determinou-se o módulo de elasticidade dinâmico para os elementos puros, Ti e Ta, e para a liga Ti-40Ta por meio das vibrações flexurais. O módulo de elasticidade encontrado para a liga, em temperatura ambiente, foi de (71 ± 5) GPa, estando em concordância com os resultados disponíveis na literatura. O valor de módulo da liga é menor quando comparado ao das ligas biomédicas comerciais e está mais próximo a do osso humano, o que a torna a liga Ti-40Ta uma potencial candidata a ser empregada em aplicações biomédicas.
17

Processamento e propriedades do sistema ferroelétrico livre de chumbo (Bi, Na)TiO3 (Bi, K)TiO3 BaTiO3

Barbosa Quiroga, David Antonio 09 March 2015 (has links)
Made available in DSpace on 2016-06-02T20:16:54Z (GMT). No. of bitstreams: 1 6698.pdf: 13275782 bytes, checksum: 2c4bbd5a5c838552f7cbf82ce709e116 (MD5) Previous issue date: 2015-03-09 / Financiadora de Estudos e Projetos / In this work, the lead-free ceramic powders of xBi0,5Na0,5TiO3 - (0,7186 - 0,7143x) Bi0,5K0,5TiO3 - (2814 - 2857x) BaTiO with x = 0,8200; 0,8625; 0,8792, 0,9126 and 0,9300 (BNBK1000x) were prepared by the solid state reaction method, followed by conventional densification. The ceramic bodies showed high density, which was higher than 95% in obtained samples. For the all ceramics were performed structural, micro structural, electric and anelastic characterizations. The X-ray diffraction (XRD) analysis indicated the formation of the complex perovskite type crystaline structure for all compositions analyzed without the presence of spurious phases. By the structural refinement by the Rietveld method of XRD data and by Raman spectroscopy were observed that for BNBK912 and BNBK930 compositions, at room temperature, the predominant symmetry is rhombohedral (R3c), while the BNBK820 composition exhibits a tetragonal crystalline symmetry (P4mm). For the BNBK879 and BNBK826 compositions presented a mixture of phases, possibly with rhombohedral and tetragonal symmetry, reaveling the morphotropic phase boundary (MPB) of this system. The microstructure of BNBK1000x ceramics was investigated by scanning electron microscopy (SEM), where the morphology grains with irregular sizes and shapes, where the increased levels of K+ and Ba2+ ions suppressed the growth of the grains. The characterizations by Raman spectroscopy at room temperature showed broad Raman modes, due to the chemical and/or structural disorder related to the substitution of elements Bi and Na for Ba and K. The ferroelectric characterizations at room temperature of the BNBK1000x ceramics showed that all compositions studied are ferroelectric. Through the comparison among the measurements of electrical impedance and mechanical spectroscopy, was possible to identify the different structural and electric phase transitions that were employed in the construction of a pseudodiagram of phases for the BNBK1000x compositions. / Neste trabalho, os pós-cerâmicos livres de chumbo xBi0,5Na0,5TiO3 - (0,7186 - 0,7143x) Bi0,5K0,5TiO3 - (2814 - 2857x) BaTiO com x = 0,8200; 0,8625; 0,8792, 0,9126 e 0,9300 (BNBK1000x) foram obtidos através do método de reação de estado sólido, seguido por densificação convencional. Os corpos cerâmicos obtidos apresentaram elevada densificação, sendo maior que 95% nas amostras produzidas. Para todas as cerâmicas foram realizadas caracterizações estruturais, microestruturais, elétricas e anelásticas. As análises por difração de raios-X (DRX) indicaram a formação da estrutura cristalina tipo perovkista complexa para todas as composições analisadas, sem a presença de fases espúrias. O refinamento estrutural, pelo método de Rietveld, dos resultados de DRX e os resultados de espectroscopia Raman apontam que para as composições BNBK930 e BNBK912 a simetria predominante em temperatura ambiente é romboédrica (R3c), enquanto que a composição BNBK820 apresenta a simetria cristalina tetragonal (P4mm). Já as composições BNBK879 e BNBK862 apresentaram uma mistura de fases, possivelmente com simetrias romboédrica e tetragonal, evidenciando o contorno de fase morfotrópico (CFM) deste sistema. A microestrutura das cerâmicas de BNBK1000x foi investigada por microscopia eletrônica de varredura (MEV), onde a morfologia apresentada pelas diferentes composições estudadas possuíam grãos com tamanhos e formatos irregulares, sendo que o aumento dos teores dos íons de K+ e Ba2+ inibiram o crescimento dos grãos. A caracterização por espectroscopia Raman, em temperatura ambiente, apresentou modos Raman amplos, mostrando um elevado grau de desordem química e/ou estrutural devido à substituição dos elementos Bi e Na por Ba e K. As caracterizações ferroelétricas, também em temperatura ambiente das cerâmicas de BNBK1000x mostraram que todas as composições estudadas possuem propriedades ferroelétricas. Através da comparação entre as medidas de impedância elétrica e anelástica, levando em consideração as caracterizações estruturais e ferroelétricas com temperatura, foi possível identificar diferentes transições de fase estruturais e elétricas, que foram empregadas na construção de um pseudo-diagrama de fases para as composições de BNBKx.
18

Influência da adição de BaTiO3 nas propriedades estruturais, elétricas e anelásticas de cerâmicas piezoelétricas de Bi0,5Na0,5TiO3-BaTiO3

Diaz, Julio Cesar Camilo Albornoz 07 August 2014 (has links)
Made available in DSpace on 2016-06-02T20:19:24Z (GMT). No. of bitstreams: 1 6248.pdf: 27691207 bytes, checksum: cc929611cc4e506743fb3b9ce1730858 (MD5) Previous issue date: 2014-08-07 / Universidade Federal de Sao Carlos / Motivated by the great growth presented in the last decade in research on lead-free piezoelectric ceramics and the fact that some ceramic systems, as those based on bismuth, have been identified as promising candidates to substitute the lead zirconate titanate (PZT) in their present technological applications, was proposed as the objective of this work, study the effect of adding 𝐵𝑎𝑇 𝑖𝑂3 (BT) on the structural, electrical and anelastic properties exhibit by the system (1−𝑥)𝐵𝑖0.5𝑁𝑎0.5𝑇𝑖𝑂3−𝑥𝐵𝑎𝑇 𝑖𝑂3 (BNT-BT). The structural characterization was performed by the techniques of X-ray diffraction (XRD) and Raman spectroscopy. The morphological and compositional aspects (qualitative), in the calcined powders, and the sintered samples were studied by scanning electron microscopy (SEM). The ferroelectric and dielectric character of the compositions were obtained through characterization of ferroelectric hysteresis exhibit and using the technique of electrical impedance spectroscopy, respectively. Phase transitions and the possible mechanisms of anelastic relaxation were studied by the technique of mechanical spectroscopy. Samples were obtained by the method of solid state reaction, where it was possible to obtain compositions with 0.00 ≤ 𝑥 ≤ 0.08 with relative density greater than 95% and without the presence of spurious or secondary phases. On profiles of X-ray diffraction for the different studied sintered compositions was applied the method of Rietvelt refinement which allow the determination and confirmation of the crystal structures in the samples under study, and the presence of a morphotropic phase boundary (MPB) for the BNT-BT. The XRD results were corroborated by the results of Raman spectroscopy. The ferroelectric nature of the different compositions of BNT-BT system studied was confirmed. Electrical phase transitions (F-Af and Af-P) and structural transitions (R-T and T-C) exhibited by the BNT-BT were characterized by mechanical spectroscopy (using a dynamical mechanical analyzer (DMA)), and by electrical impedance spectroscopy, employing the results in complementing the electrical and structural phase diagram of this system. In addition to the phase transitions obtained, the technique of mechanical spectroscopy for compositions between 0.00 ≤ 𝑥 ≤ 0.03, allowed the observation of a complex process of anelastic relaxation that was associated with interactions and mobility of different defects present, which possibly contribute significantly to an increase of conductivity in these materials, which had not been previously reported in the literature. / Motivados pelo grande crescimento apresentado na última década nas pesquisas em cerâmicas piezoelétricas livres de chumbo e o fato de alguns sistemas cerâmicos, como os baseados em bismuto, já terem sido identificados como promissores candidatos à substituição do titanato zirconato de chumbo (PZT) em suas atuais aplicações tecnológicas, foi proposto como objetivo deste trabalho, estudar a influência da adição de 𝐵𝑎𝑇 𝑖𝑂3 (BT) sobre as propriedades estruturais, elétricas e anelásticas exibidas pelo sistema (1 − 𝑥)𝐵𝑖0,5𝑁𝑎0,5𝑇𝑖𝑂3 − 𝑥𝐵𝑎𝑇 𝑖𝑂3 (BNT-BT). A caracterização estrutural foi realizada por meio das técnicas de difração de raios-X (DRX) e espectroscopia Raman. Os aspectos morfológico e composicional (qualitativo), tanto dos pós calcinados, quanto das amostras sinterizadas foram estudados mediante microscopia eletrônica de varredura (MEV). O caráter ferroelétrico e dielétrico das composições estudadas foram obtidos por meio da caracterização da histerese ferroelétrica exibida e da técnica de espectroscopia de impedância elétrica, respectivamente. As transições de fase e os possíveis mecanismos de relaxação anelástica foram estudados utilizando a técnica de espectroscopia mecânica. As amostras foram obtidas pelo método de reação de estado sólido, onde foi possível obter composições com 0, 00 ≤ 𝑥 ≤ 0, 08 com densidades relativas maiores que 95% e sem a presença de fases espúrias ou secundárias. Aos perfis de difração de raios-X para as diferentes composições sinterizadas estudadas foi aplicado o método de refinamento Rietvelt que permitiu a determinação e confirmação das estruturas cristalinas nas amostras em estudo, além da presença de contorno de fase morfotrópico (CFM) para o BNT-BT. Os resultados de DRX foram corroborados por meio dos resultados de espectroscopia Raman. O carácter ferroelétrico das diferentes composições do sistema BNT-BT estudadas foi confirmado. Tanto as transições de fase elétricas, ferroelétricaantiferroelétrica (F-Af) e antiferroelétrica-paraelétrica (Af-P), quanto as transições estruturais, romboédrica-tetragonal (R-T) e tetragonal-cubica (T-C), exibidas pelo BNT-BT foram caracterizadas por espectroscopia mecânica (por meio de um analisador dinâmico mecânico(DMA)) e por espectroscopia de impedância elétrica, empregando-se os resultados obtidos na complementação do diagrama de fase elétrico e estrutural deste sistema. Além das transições de fase obtidas, a técnica de espectroscopia mecânica, para composições entre 0, 00 ≤ 𝑥 ≤ 0, 03, propiciou a observação de um processo de relaxação anelástica complexo que foi associado a interações e mobilidade de diferentes defeitos presentes, que possivelmente contribuem significativamente para um aumento de condutividade nestes materiais, que não haviam sido reportado anteriormente na literatura.
19

Efeito de oxigênio na biocompatibilidade e propriedades da liga Ti-15Mo

Martins Júnior, José Roberto Severino [UNESP] 23 September 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:30:19Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-09-23Bitstream added on 2014-06-13T19:18:57Z : No. of bitstreams: 1 martinsjunior_jrs_me_bauru.pdf: 3438842 bytes, checksum: c98511273a55e7af07b24dd5b19c844f (MD5) / Desde 1970, o titânio e algumas de suas ligas são vastamente usados na fabrição de próteses e dispositivos especiais nas áreas médica e odontológica devido às suas propriedades como baixos valores de módulo de elasticidade (Módulo de Young), resistência à corrosão e características de biocompatibilidade. A presença de elementos intersticiais (oxigênio, carbono, nitrogênio e hidrogênio) altera de maneira significativa as propriedades mecânicas da liga, principalmente suas propriedades elásticas, causando endurecimento ou fragilização da liga. As medidas de espectroscopia mecânica constituem uma ferramenta poderosa para o estudo da interação destes elementos substitucionais e intersticiais com a matriz metálica. O objetivo do trabalho foi prepararA LIGA Ti-15Mo por fusão a arco, e estudar a influência de tratamentos térmicos e do oxigênio presente em solução sólida, na estrutura, propriedades mecânicas, químicas, anelásticas e biocompatibilidade da liga. Os resultados de difração de raios X analisados pelo método de Rietveld permitiram quantificar as fases presentes na microestrutura, estando de acordo com as micrografias obtidas. Os resultados de dureza e módulo de elasticidade mostraram ser sensíveis à concentração de oxigênio e à microestrutura da liga. Nos ensaios de corrosão houve uma melhora significativa do potencial de corrosão após as dopagens com oxigênio. As medidas de espectroscopia mecânica apresentaram estruturas de relaxação e foram identificados os processos constituintes. Os ensaios de biocompatibilidade mostraram que a liga em questão pode ser considerada biocompatível / Since 1970, titanium and some of its alloys have been widely used in the manufacture of special devices and prostheses in medical and dental areas due to properties which include low elasticity modulus values, corrosion resistance and characteristics of biocumpatibility. The presence of interstial elements (carbon, nitrogen, oxygen and hydrogen) significantly alters the alloy's mechanical properties, mainly its elastic properties, causing either a hardening or softening of the alloy. Mechanical spectroscopy measurements are a powerful tool to study the interaction of these substitutional and interstitial elements with a metallic matrix. The aim of this work was to prepare the Ti-15Mo alloy by arc-melting and study the influence of heat treatments and oxygen present in the solid solution of the structure, as well as the mechanical, chemical and anelastic properties, and biocompatibility of the alloys. The results of x-ray diffraction were analyzed by the Rietveld Method to allow the phases present in the microestructure to be quantified according to the obtained micrographies. The hardness and elasticity modulus results were sensitive to the oxygen concentration and the alloy microstructure. In corrosion tests there was a significant improvement of the corrosion potential after the oxygen dopyng. The mechanical spectroscopy measurements showed relaxation structures, and constituent relaxation processes were identified. The biocompatibility tests showed that the alloy in question can be considered biocompatible
20

Efeito de oxigênio na biocompatibilidade e propriedades da liga Ti-15Mo /

Martins Júnior, José Roberto Severino. January 2010 (has links)
Orientador: Carlos Roberto Grandini / Banca: Marize Varella de Oliveira / Banca: Nilson Tadeu Camarinho de Oliveira / O Programa de Pós-Graduação em Ciência e Tecnologia de Materiais, PosMat, tem caráter institucional e integra as atividades de pesquisa em materiais de diversos campi da Unesp / Resumo: Desde 1970, o titânio e algumas de suas ligas são vastamente usados na fabrição de próteses e dispositivos especiais nas áreas médica e odontológica devido às suas propriedades como baixos valores de módulo de elasticidade (Módulo de Young), resistência à corrosão e características de biocompatibilidade. A presença de elementos intersticiais (oxigênio, carbono, nitrogênio e hidrogênio) altera de maneira significativa as propriedades mecânicas da liga, principalmente suas propriedades elásticas, causando endurecimento ou fragilização da liga. As medidas de espectroscopia mecânica constituem uma ferramenta poderosa para o estudo da interação destes elementos substitucionais e intersticiais com a matriz metálica. O objetivo do trabalho foi prepararA LIGA Ti-15Mo por fusão a arco, e estudar a influência de tratamentos térmicos e do oxigênio presente em solução sólida, na estrutura, propriedades mecânicas, químicas, anelásticas e biocompatibilidade da liga. Os resultados de difração de raios X analisados pelo método de Rietveld permitiram quantificar as fases presentes na microestrutura, estando de acordo com as micrografias obtidas. Os resultados de dureza e módulo de elasticidade mostraram ser sensíveis à concentração de oxigênio e à microestrutura da liga. Nos ensaios de corrosão houve uma melhora significativa do potencial de corrosão após as dopagens com oxigênio. As medidas de espectroscopia mecânica apresentaram estruturas de relaxação e foram identificados os processos constituintes. Os ensaios de biocompatibilidade mostraram que a liga em questão pode ser considerada biocompatível / Abstract: Since 1970, titanium and some of its alloys have been widely used in the manufacture of special devices and prostheses in medical and dental areas due to properties which include low elasticity modulus values, corrosion resistance and characteristics of biocumpatibility. The presence of interstial elements (carbon, nitrogen, oxygen and hydrogen) significantly alters the alloy's mechanical properties, mainly its elastic properties, causing either a hardening or softening of the alloy. Mechanical spectroscopy measurements are a powerful tool to study the interaction of these substitutional and interstitial elements with a metallic matrix. The aim of this work was to prepare the Ti-15Mo alloy by arc-melting and study the influence of heat treatments and oxygen present in the solid solution of the structure, as well as the mechanical, chemical and anelastic properties, and biocompatibility of the alloys. The results of x-ray diffraction were analyzed by the Rietveld Method to allow the phases present in the microestructure to be quantified according to the obtained micrographies. The hardness and elasticity modulus results were sensitive to the oxygen concentration and the alloy microstructure. In corrosion tests there was a significant improvement of the corrosion potential after the oxygen dopyng. The mechanical spectroscopy measurements showed relaxation structures, and constituent relaxation processes were identified. The biocompatibility tests showed that the alloy in question can be considered biocompatible / Mestre

Page generated in 0.0403 seconds