• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 527
  • 25
  • 25
  • 25
  • 23
  • 14
  • 13
  • 13
  • 12
  • 8
  • 6
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 537
  • 200
  • 161
  • 101
  • 91
  • 85
  • 81
  • 74
  • 71
  • 71
  • 70
  • 70
  • 69
  • 68
  • 67
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Concepção morfológica de fórceps, para intervenção no paciente em posição supina e o operador sentado /

Naressi, Wilson Galvão. January 1997 (has links)
Banca: Antenor Araújo / Banca: Nemre Adas Saliba / Banca: Jaime Renato Furquim de Castro / Banca: Renato Luis Ference / Banca: Roberto Antonio Nicodemo / Resumo: A Ergonomia, ciência da racionalização do trabalho, busca o total entrosamento do homem e seus instrumentos de trabalho. Em Odontologia, a Ergonomia se faz presente no ato do profissional trabalhar corretamente sentado, em situação de conforto funcional, intervindo em paciente na posição supina, contando com equipamento e instrumental adequadamente concebidos. Atualmente, o equipamento odontológico está devidamente racionalizado; no entanto, determinados instrumentos necessitam ser redesenhados, para melhor se ajustarem àqueles requisitos. O projeto de um instrumento manual deve permitir manejo cômodo, firme e seguro. Devem-se considerar detalhes anatômicos, posição correta do operador quando da intervenção e características específicos de utilização. O instrumento ora em análise - fórceps para molares inferiores - foi concebido dentro desses requisitos, em conjunto com novo sistemática de exodontia via alveolar, consubstanciada em estudos eletromiográficos e biomecânicos. A morfologia do instrumento, que possibilita cinético simples e natural do operador, foi obtida por mudança no paradigma dos instrumentos de ação cruzado convencionais (cuja apreensão ocorre sobre as hastes), desvinculando-se o "cabo" do "braço da hoste". Isto induziu a concepção anatômica de empunhaduras perpendiculares às extremidades das hastes, resultando em instrumento eficiente e eficaz, conforme indicado em sua fase de experimentação / Abstract: Ergonomics, the science of working rationalization, seeks the best relationship between man and his working tools. In Dentistry, ergonomics is present as for the professional working correctly seated, in functional comfort, intervening of supine position patient, by means of suitable equipment and instrument. Nowadays, dental equipment is justly rationalized; however, some instruments should take shape, in order to adapt those requirements. The hand tool design should permit a comfortable, non-slip and safe handling. Thus, anatomical details, the correct position of the operator for its use and specific characteristics of application should be taken into account. The instrument under analysis - forceps - was conceived according to these requirements along with a new alveolar tooth extraction technique, based on electromyographic and biomechanical studies. The morphology of the instrument, which makes possible a simple and natural kinetics of the operator, was obtained by changing the paradigm of the conventional cross-action instruments (whose grip is always on the arms of the tool), divesting the "handle" from the "tool arm". This induced on anatomical conceiving of perpendicular handles to the extremity of the tool arm, resulting an efficient and effective instrument, according to indicated on its experimental phase
82

Controle de qualidade em radiodiagnóstico: metodologia para adaptação de técnicas radiográficas entre aparelhos de raios-X / not available

Oliveira, Ricardo Coura 06 February 2004 (has links)
O presente trabalho trata de uma metodologia para adaptação de técnicas radiográficas entre diferentes aparelhos de Raios-X, para que os mesmos operem de maneira coordenada em exames radiográficos, produzindo um mesmo padrão de imagem no final do processo. Também sistematiza procedimentos de controle de qualidade das grandezas tensão elétrica, camada semi-redutora, rendimento e fator Bucky. Para tanto, além da utilização de fantomas simuladores de órgãos, é utilizado um sistema computacional que engendra funções de ajuste referentes a cada grandeza em cada aparelho de Raios-X avaliado. Foram produzidas imagens radiográficas de crânio e pelve com alta qualidade, que após passarem por avaliações subjetiva e quantitativa, comprovaram a eficiência da pesquisa. Com a metodologia proposta é possível reduzir a taxa de repetição de exames, em um serviço de radiodiagnóstico, decorrente das diferenças entre os equipamentos de Raios-X existentes . / The present work is about a methodology for adaptation of technical radiographics among different machines of Ray-X, so that the same ones operate of way coordinate in exams radiographics, producing a same image pattern in the end of the process. It also systematizes procedures of control of quality of the greatness electric tension, half value layer, output and factor Bucky. For so much, besides the use of phantoms simulators of organs, it is used a system of computer that engenders referring adjustment functions to each greatness in each machine of Ray-X appraised. Images cranium radiographics and pelvis were produced with high quality, that after they go by subjective and quantitative evaluations, they checked the efficiency of the research. With the methodology proposal it is possible to reduce the rate of repetition of exams, in a radiodiagnosis service, due to the differences among the equipments of Ray-X existent.
83

Índice de sucesso e fatores clínicos associados à estabilidade de mini-implantes ortodônticos: revisão sistemática e meta-análise / Success rate and clinical factors associated with the stability of orthodontic mini-implants: a systematic review and metaanalysis

Santos, Sandro Henrique Batista 28 February 2016 (has links)
Submitted by Márcio Ropke (ropke13marcio@gmail.com) on 2017-06-21T13:43:13Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) ndice de sucesso e fatores clínicos associados à estabilidade de miniimplantes.pdf: 1928608 bytes, checksum: 10cac1cb5f72180dbbf04dc1cf6a63dc (MD5) / Made available in DSpace on 2017-06-21T13:43:13Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) ndice de sucesso e fatores clínicos associados à estabilidade de miniimplantes.pdf: 1928608 bytes, checksum: 10cac1cb5f72180dbbf04dc1cf6a63dc (MD5) Previous issue date: 2016-02-28 / Sem bolsa / Os mini-implantes ortodônticos têm se mostrado uma ferramenta extremamente útil na ortodontia contemporânea no quesito ancoragem esquelética, e nos últimos anos são objeto de diversos estudos que tentam demonstrar sua eficácia e utilidade, principalmente como meio auxiliar em mecânicas e movimentos ortodônticos até então considerados complexos. Esta revisão avaliou o índice de sucesso dos miniimplantes utilizados como dispositivos de ancoragem esquelética temporária em ortodontia, e também os fatores clínicos associados à estabilidade do mesmo durante à necessidade de permanência, como a influência da localização no arco (maxila ou mandíbula), instalado por lingual ou vestibular, diâmetro e comprimento do mini-implante, gênero do paciente, idade do paciente, se a aplicação da força foi mediata ou imediata e marca comercial. Para isso foi realizada uma pesquisa nas bases de dados PubMed, Embase e Cochrane Collaboration’s CENTRAL, e também uma pesquisa manual identificando ensaios clínicos controlados randomizados e não randomizados que tivessem realizado a instalação de mini-implantes em pacientes ortodônticos e que avaliaram o índice de sucesso geral, contendo os casos de sucesso/falha na maxila e mandíbula. Foram encontrados 804 artigos. A seguir foi realizada a avaliação dos títulos e resumos considerando-se os critérios de inclusão, sendo incluídos para análise 16 estudos. Os dados coletados foram organizados em uma tabela em conjunto com o nome do autor e ano de publicação. Foi realizada uma descrição narrativa e meta-análise para comparação das variváveis e apresentação em gráficos para visualização dos resultados. Avaliando o resultado estatístico, os mini-implantes ortodônticos apresentaram uma taxa geral de sucesso de 83,7%. A meta-análise mostrou um índice de sucesso maior na maxila quando comparada à mandíbula (p<0,001). Como conclusão podemos considerar os mini-implantes uma modalidade viável de tratamento para uso na clínica ortodôntica. / Orthodontic mini-implants have shown to be an extremely useful tool in contemporary orthodontics in skeletal anchorage, and in recent years are the subject of several studies attempting to demonstrate their effectiveness and usefulness, especially as aiding mechanical and orthodontic movements considered complex. This review evaluated the success rate of mini-implants used as temporary skeletal anchorage devices in orthodontics, as well as the clinical factors associated with stability as the influence of location on the arch (maxilla or mandible), lingually or buccally positioned, diameter and length of the mini-implant, patient gender, patient's age, whether the application of force was mediately or immediately after delivery and trademark. For that a search in PubMed, Embase and the Cochrane Collaboration 's CENTRAL databases was performed as well as a manual search identified randomized controlled trials and non-randomized patients that performed the installation of mini-implants in orthodontic patients and evaluating their success rates and contained the cases of success / failure in the maxilla and mandible. Overall, 804 articles were found. Next, titles and abstracts were analyzed and considering the inclusion criteria 16 studies were included for analysis. The data collected were organized in a table together with the author's name and year of publication. A narrative description and meta- analysis to compare the variables was performed. Evaluating the statistical result, orthodontic mini-implants showed an overall success rate of 83.7%. The meta-analysis showed a higher success rate in the maxilla compared to the mandible (p<0.001). In conclusion, mini-implants are a viable treatment modality for use in orthodontic practice, with high success rates.
84

Avaliação das vias aéreas superiores após uso do aparelho Herbst, por meio de sobreposição tridimensional / Evaluation of the upper airways after use of the Herbst appliance, via superposition of tridimensional images

Palomino-Gómez, Sandra Patricia [UNESP] January 2015 (has links) (PDF)
Made available in DSpace on 2017-03-14T14:10:06Z (GMT). No. of bitstreams: 0 Previous issue date: 2015. Added 1 bitstream(s) on 2017-03-14T14:42:47Z : No. of bitstreams: 1 000874648.pdf: 1962285 bytes, checksum: 509cd79e4e32dd7535b77a44ed7897de (MD5) / As mudanças nos padrões de respiração nasal afetam profundamente o crescimento craniofacial. Avanços tecnológicos, como a tomografia computadorizada de feixe cônico (TCFC), têm sido utilizados com o propósito de se observar tridimensionalmente a localização de diferentes estruturas do crânio, a face e o espaço aéreo faríngeo. Desta forma, é possível avaliar as alterações do espaço aéreo induzidas pelos aparelhos ortopédicos propulsores mandibulares. O intuito deste estudo foi avaliar as mudanças na faringe superior resultantes do avanço mandibular com aparelho Herbst, mediante análise do método de sobreposição de coordenadas tridimensionais matemáticas. A amostra deste estudo está composta por 24 pacientes, 10 do gênero feminino e 14 do gênero masculino (16,1 anos no início de tratamento), tratados por 8 meses com aparelho Herbst, sendo comparados com o grupo controle composto de 7 pacientes do gênero feminino (13,54 anos ao início do T1). Todos os indivíduos apresentavam má oclusão classe II divisão 1ª e já haviam passado pelo surto de crescimento pubertário (avaliados e pareados com radiografia de mão e punho). Os exames tomográficos foram realizados em dois tempos para cada paciente. A fase inicial foi realizada com a localização e identificação de 79 pontos anatômicos nos eixos: axial, coronal e sagital, sendo que 26 pontos anatômicos (base do crânio, maxila, mandíbula   37   vértebra e hióide) foram adotados para a análise final com auxílio do software AVIZO®. Após o processo de calibração, cada variável foi mensurada três vezes. A análise estatística dos dados foi realizada por meio do Test de Levane e teste T de Student ao nível de significância de 5 %. A confiabilidade das medidas apresentaram boa replicabilidade (ICC ≥ 0,921), com exceção da borda superior de vértebra cervical 3 e dos pontos inferiores da coana... (Resumo completo, clicar acesso eletrônico abaixo) / Changes in nasal breathing pattern affect the craniofacial growth. Technological advances, such as Cone beam computed tomography (CBCT), have been used in order to observe three-dimensionally (3D) the skull, face and pharyngeal airway space. The latter, with possible assessment of airway changes induced by orthopedic activators. The aim of this study was to evaluate the changes of the upper airway space resulted from mandibular advancement with Herbst appliance through superposition method of mathematical 3D coordinates. The sample was composed of 24 patients, 10 females and 14 males (16.1 years at the start of treatment - T1) treated for 8 months with Herbst appliance, and compared with a group control composed of 7 females (13.54 yrs at T1). Individuals of the samples were patients with malocclusion Class II division 1, already been through the pubertal growth spurt. The growth sprunt was assessment with hand/wrist radiographs. For each patient, CBCT scans were performed in two stages. The initial phase was conducted by location and identification of 79 anatomical points in the shaft, axial, coronal and sagittal views. Twenty-six anatomical points (skull base, maxilla, vertebra and Hyoid jaw) were adopted for the final analysis using Avizo analysis software®. After calibration of the examiner, each variable was measured three times. The statistical analysis was performed using Levene Test and t-Test with   39   significance level of 5%. The reliability of the measurements showed good reproducibility (ICC ≥ 0.92), exception were the top edge of cervical vertebra 3 and lower border of the Choanae. The results indicated statistical significance in axis Z for PNS (p = 04) compared to control group and for to tip of the epiglottis (p=0.02) compared with control group. Other structures, which were statistically significant, were the left portion of the greater cornu of hyoid...(Complete abstract electronic access below)
85

Influência do design de órteses de punho e mão no desconforto, transmissão de torque e desempenho em tarefas manuais /

Ferrari, Ana Lya Moya. January 2019 (has links)
Orientador: Fausto Orsi Medola / Banca: Sergio Tosi Rodrigues / Banca: Milton José Cinelli / Resumo: As lesões nos membros superiores causam impacto direto na vida de um indivíduo. As órteses são dispositivos utilizados para a reabilitação desses membros e, assim como as demais Tecnologias Assistivas, necessitam da adaptação e aceitação do usuário. O aumento de incentivo às pesquisas em Tecnologia Assistiva é um fator favorável ao desenvolvimento de órteses uma vez que traz a tona questões referentes à ergonomia e ao desempenho destes dispositivos; aspectos importantes a serem considerados para garantir a eficiência fisiológica e funcional do equipamento e a adaptação do usuário. Todas essas informações podem auxiliar no design de órteses mais ergonômicas e, portanto, mais apropriadas às necessidades e expectativas dos consumidores. O presente estudo teve como objetivo avaliar e comparar o desempenho, desconforto e transmissão de força de torque em tarefas manuais em quatro condições: três órteses pré-fabricadas de punho e mão, feitas de neoprene e lona, e mão livre, através de tarefas simuladas e da avaliação de torque manual. A avaliação de desconforto mostrou diferenças na percepção de desconforto entre todas as órtese e revelou regiões que devem receber maior atenção no projeto desses dispositivos a fim de garantir o conforto do usuário. Com relação ao desempenho na realização das tarefas de digitação e escrita manual, foram observadas diferenças estatísticas significativas entre condições avaliadas, sendo que a órtese Lona apresentou os maiores valores de dificuldade e ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Upper limb injuries have a direct impact on an individual's life. Orthoses are devices used in the rehabilitation of these members and, like the other Assistive Technologies, they need the adaptation and acceptance of the user. The increased incentive to research in Assistive Technology is a beneficial factor for the development of orthotics since they raise questions regarding the ergonomics and performance of these devices; important aspects to be considered to guarantee the physiological and functional efficiency of the equipment and user's adaptation. All this information can support the design of orthoses more ergonomic and, therefore, better suitable for consumer's needs and expectations. The present study aimed to compare performance, discomfort and torsion transmission in manual tasks under various conditions: Three pre-fabricated wrist and hand orthosis, made of neoprene and canvas, and free hand, through simulated tasks and manual torque evaluation. The discomfort evaluation showed differences in the perception of discomfort among all orthoses and revealed regions that should receive attention during the design of these devices in order to guarantee user's comfort. Regarding the performance in the tasks of typing and hand writing, significant statistical differences were observed between the evaluated conditions and Canvas orthosis showed the highest values of difficulty and time in the accomplishment of the tasks. Significant statistical differences in torque trans... (Complete abstract click electronic access below) / Mestre
86

Efeito da distância interbraquetes sobre o sistema de forças em alças de retração ortodôntica com geometria delta: estudo numérico experimental

Ferreira, Marcelo do Amaral 31 March 2010 (has links)
CAPES / O presente trabalho estudou por meio do Método dos Elementos Finitos e por testes experimentais o efeito da distância interbraquetes, ativação e geometria (variáveis independentes) sobre o sistema de forças (Fx, Fy e Mz) produzidos por alças delta após ativação. As amostras foram produzidas com titânio-molibdênio, com secção transversal 0.017 x 0.025 polegadas (0,43mm x 0,64mm) e separadas em dois grupos (G1 e G2), com dez alças cada um. O grupo de alças G1 apresenta hastes com inclinação em suas extremidades. O Grupo G2 hastes com extremidades arredondadas. Visando identificar diferenças entre as médias populacionais devidas a três possíveis causas ou fontes de variação (variáveis independentes) e as interações entre as mesmas (geometria, distância interbraquetes e ativação), utilizou-se a método de análise de variância a três critérios de classificação, modelo fatorial completo (ANOVA). O método de análise de variância aceita ou rejeita a(s) hipótese(s) H0 de igualdade das médias populacionais. Se H0 for rejeitada, admite-se que pelo menos uma das médias é diferente das demais. Nestas condições utilizou-se o teste proposto por Games-Howell para variâncias heterogêneas, visando estabelecer comparações entre os diferentes tratamentos. Para estimar a constante elástica para os dois tratamentos (G1 e G2), utilizou-se a análise de regressão para verificar o grau de relacionamento entre os valores da variável resposta (força Fx) e a variável independente (ativação da alça). Os Grupos G1 e G2 apresentaram magnitudes de força compatíveis com as descritas pela literatura (houve variação de 81,65gf até125gf para o grupo G1 e de 92,45gf até 133,10gf para G2, aos 3.0mm e 4.0mm de ativação, respectivamente para Fx). As forças verticais Fy foram de 50gf e 16gf para G1 e G2, aos 4.0mm, respectivamente, e 52,15gf e 26,95gf para G1 e G2 aos 3.0mm de ativação, respectivamente. A constante de mola encontrada para os grupos estudados mostrou estar dentro de limites apropriados para uso clínico, resultando 27,95gf/mm para G1 e 32,09 para G2. A relação M/F aumentou à medida que as alças desativavam. As alças mostraram ser adequadas para a retração de caninos desde que ativadas até aos 4,0mm e reativadas após 2,0mm de desativação. A relação M/F média foi de 9,2mm aos 4,0 mm de ativação e de 13mm aos 3,0mm para G1 enquanto que para G2 os valores médios foram de 9,3mm aos 4,0mm de ativação e13mm aos 3,0mm. Não houve diferença significativa entre os grupos. A variável independente ativação causou diferença estatística significativa nos resultados das variáveis dependentes (Fx, Fy e Mz). As diferentes distâncias interbraquetes não influenciaram de maneira significativa o sistema de forças. A variável grupo influenciou de maneira significativa os valores de Fy e Mz. / The present study tested experimentally and by Finite Element Method the effect of inter-bracket distance (IBD), activation and geometry (independent variables) on the force system (Fx, Fy, Mz) produced by delta springs after activation. The springs were produced with titanium-molybdenum 0.017 x 0.025 in (0,43mm x 0,64mm), and separated in two groups (G1 and G2) with ten springs each one. The springs in group G1 presented angulated legs and in the group G2 rounded legs. Analysis of factorial variance averages caused by three possible variation (inter brackets distance, geometry and activation) sources and the interactions between them. Regression analysis was also performed to obtain the spring rate. Groups G1 and G2 presented force magnitudes which are compatible with the ones mentioned in the literature related to the subject (varying from 81,65gf to 125gf for G1 and from 92,45gf to 133,10gf for G2, at 3.0mm and 4.0mm of activation, respectively for Fx). The vertical Fy forces were 50 gf and 16gf for G1 and G2, at 4.0mm, respectively, and 52,15gf and 16,95 gf for G1 and G2 at 3.0mm of activation, respectively. The spring constants have proved to be within the levels which are appropriate for clinical use, resulting 27,95gf/mm for G1 and 32,09 for G2 groups. The mean moment-to-force ratio (M/F) was M/F=9,2mm at 4,0 mm of activation and 13mm at 3,0mm of activation for G1 group, whereas for G2 the mean values were M/F=9,3mm at 4,0mm of activation and M/F=13mm at 3,0mm. The M/F ratio incresead as the springs deactivated. There was no statistical differences between groups. IBD and geometry does not cause significative influence on force systems resulting from activations, but activation that produced statistical difference on force system (Fx, Fy and Mz).
87

Avaliação cefalométrica das alterações esqueléticas, dentárias do perfil facial naturais e induzidas pelos aparelhos de Herbst e Bionator no tratamento da má oclusão de Classe II, divisão 1ª

Nunes, Ingrid Madeira de Barros [UNESP] 30 March 2011 (has links) (PDF)
Made available in DSpace on 2015-03-03T11:52:42Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-03-30Bitstream added on 2015-03-03T12:07:09Z : No. of bitstreams: 1 000806396.pdf: 8802037 bytes, checksum: ef23cd8b10d2117d60e9d2c9d038c120 (MD5) / O objetivo deste estudo foi avaliar as alterações esqueléticas, dentárias e do perfil facial naturais e induzidas pelos aparelhos de Herbst e Bionator no tratamento da má oclusão de Classe II, divisão 1ª. Para tanto, se utilizou uma amostra de 90 telerradiografias laterais de 45 indivíduos no estágio prépubertário, subdivididos em dois grupos experimentais e um controle. O primeiro grupo, composto por 15 indivíduos brasileiros, com idade média inicial de 9,4 anos, foi tratado com o aparelho de Herbst por um período de 7 meses. O segundo grupo experimental, composto por 15 indivíduos brasileiros, leucodermas, com idade média inicial de 9,9 anos foi submetido a bionatorterapia por um período médio de 21 meses. O grupo controle de 15 indivíduos, não tratados ortodonticamente, provém do Burlington Growth Centre, Universidade de Toronto, Canadá. A comparação intragrupo foi realizada por meio do teste t de Student e a comparação intergrupos por meio da ANOVA complementada pelo teste de Bonferroni. Os resultados evidenciaram que ambas as terapias não influenciam o desenvolvimento da maxila, atuam de maneira favorável na mandíbula e na relação maxilomandibular, tendem a aumentar a altura facial ântero-inferior (AFAI) e altura facial posterior (AFP), em maior proporção nesta última, sendo o incremento estatisticamente significante apenas no grupo do Bionator. Apenas o grupo tratado pelo aparelho de Herbst mostrou alterações dentárias e do perfil facial significativas para as variáveis relação molar, sobressaliência e sobremordida, convexidade facial e protrusão do lábio inferior. / The aim of this study was to evaluate the dental changes both natural and induced by Herbst’ appliance and Bionator in the treatment of Class II, division 1 malocclusion. In order to do that, we used a sample of 90 lateral radiographs of 45 individuals in pre-pubertal stage, divided up into two experimental groups and one control. The first group, composed of 15 Brazilian individuals, with initial mean age of 9.4 years, was treated with the Herbst appliance for a period of seven months. The second experimental group consisting of 15 Brazilian individuals, initial mean age of 9.9 years has gone through bionatortherapy for an average period of 21 months. The control group of 15 individuals, who were not treated orthodontically, comes up from the Burlington Growth Centre, University of Toronto, Canada. The intragroup comparison was performed using the Student t test and intergroup comparisons by ANOVA complemented by the Bonferroni test. The results have shown that both therapies have no influence at all in the development of the jaw, acting favorably in the mandible as well as in the maxillomandibular relationship,toward increasing lower anterior facial height (LAFH) and posterior facial height (PFH), with greater proportion in the last one, bearing in mind, however, that the increase is statistically significant only in bionatorgroup. Only the group treated with the Herbst appliance presented significant dental and on facial profile changes in the variables :molar relationship,overjet, overbite, convexity and lower lip protrusion.
88

Desenvolvimento e avaliação dos efeitos e segurança de um protótipo de órtese de quadril para pacientes submetidos a artroplastia de ressecção tipo girdlestone : relato de caso

Luz, Livia Lobel da January 2017 (has links)
A cirurgia de Girdlestone é um procedimento que altera o estilo de vida dos pacientes gerando alterações na postura, na marcha e nas atividades de vida diária. Nesse contexto, as órteses de quadril são utilizadas como um adjunto no processo de reabilitação favorecendo o tratamento terapêutico, contudo órteses específicas para estes pacientes não estão disponíveis no mercado nacional. Assim, o estudo teve como objetivo desenvolver e confeccionar um protótipo de órtese de quadril e avaliar os efeitos e a segurança do dispositivo na reabilitação funcional dessa população. A participante da pesquisa realizou o Protocolo Fisioterapêutico do Hospital de Clínicas de Porto Alegre associado ao uso do protótipo de órtese de quadril. Os efeitos da órtese na reabilitação funcional foram avaliados através do questionário Harris Hip Score, teste de caminhada dos seis minutos e escala visual analógica da dor. A segurança foi avaliada através da análise dos dados registrados no formulário de eventos adversos. O dispositivo é composto por duas partes: uma cinta abdominal e uma cinta que envolve a coxa ligadas por faixas elásticas ajustáveis as quais proporcionam conforto além de facilidade para colocação. O estudo gerou resultados indicativos de que o dispositivo apresentado é viável e pode ser utilizado como adjuvante na reabilitação. O modelo proposto agregou melhora do desempenho físico, do alívio de dor, da funcionalidade além de ser seguro. Além disso, este estudo ofereceu um modelo de tecnologia assistiva confeccionado com custo inferior aos importados para o mercado. Contudo, é necessário um estudo mais amplo para gerar conclusões significativas. / Girdlestone procedure is a surgical operation that causes lifestyle changes in patients followed by modifications in posture, gait and activities in everyday life. In this context, hip orthoses are used as an adjunct in the rehabilitation process supporting the therapeutic treatment. However, these devices are not available in the brazilian market. Thus, the study aimed to develop and make a prototype of a hip orthosis and to evaluate the effects and safety of the device in the functional rehabilitation of this population. The research participant performed the physiotherapeutic protocol of the Hospital de Clínicas de Porto Alegre associated to the use of the hip orthosis’ prototype. The effects of orthosis on functional rehabilitation were rated by using the Harris Hip score, six-minute walk test and visual analogue pain scale. Safety was rated by analyzing the data recorded on the adverse events form. The device consists of two parts: an abdominal strap and a thigh-wrapped strap attached by adjustable elastic straps which provide comfort and make it easy to apply the product. The results indicated that the device is suitable and can be used as an adjuvant in rehabilitation. The proposed model promoted improvement in physical performance, pain relief, functionality and it’s also safe. In addition, this research developed an assistive technology model made at a lower cost than those ones imported. However, a larger study is needed to produce more meaningful conclusions.
89

Avaliação da esterilização realizada por meio de estufas (Forno de Pasteur) em consultorios odontologicos da grande Florianopolis/SC, Brasil

Serratine, Ana Claudia Prudencio January 1998 (has links)
Dissertação (Mestrado) - Universidade Federal de Santa Catarina, Centro de Ciencias da Saude / Made available in DSpace on 2012-10-17T03:50:53Z (GMT). No. of bitstreams: 0Bitstream added on 2016-01-09T00:54:10Z : No. of bitstreams: 1 148753.pdf: 3704307 bytes, checksum: 1e6552e3ac0e08da4c85b2e10fc73660 (MD5) / Este trabalho verificou a eficácia da esterilização realizada por meio de estufas, em consultórios da Grande Florianópolis. através do uso de parâmetros fisicos (tempo e temperatura que foi medida com termômetro calibrado pelo INMETRO) e parâmetro biológico (uso de indicador B. subtilis). Concluiu que, provavelmente, apenas 48,1% das estufas da Grande Florianópolis estavam operando segundo as normas de tempo e temperatura preconizadas na literatura e pode constatar que houve falha de 22,5% na eficácia das 40 estufas da amostra testada. Abstract : The purpose of this study was to evaluate the effectiveness of dry heat dental offices in Florianópolis, S.C., Brazil. The work intended to discover the capacity dry heat ovens have to eradicate the spores of B. subtilis on biological indicators strips and also to compare temperatures during the sterilization cycles to the ones proposed in the literature. Moreover, it endeavored to assure that the built in thermometer and thermostat in the dry heat oven were reliable, and to analyze the influence how the materials were displayed in the sterilization chambers. As a complementing part, a survey was made in order to investigate who operates the dry heat ovens in different dental clinics and their specialist field of work. The results indicated that, out of the samples tested, a rate fall of 22.5% was found in dry heat ovens effectiveness to destroy the spores of R subtilis. Moreover, from the final results, it is possible to infer that only 48.1 % of the dry heat ovens investigated actually used the parameters (time and temperatare) as proposed in the literature. From the observed samples, it was also shown that the built in thermometers and thermostat were not reliable. Furthermore, results suggested that there was temperature variation inside the dry heat ovens, therefore, it was found that the materials placed in the upper shelf received less heat. Finally, findings confirmed that dental assistants were responsible for managing the dry heat ovens in 67.5% of the dental offices surveyed. Last but no least, although there was a vast area of specialists participating in the survey, such as periodontics, prosthodontics, orthodontics, endodontics, implantodontics, pedodontics, and radiology, general clinics showed to have participated with the highest percentage (57.5%).
90

Projeto de um pré-amplificador para aparelho de auxílio à audição

Campana Valderrama, Franco Renato 25 October 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Elétrica, Florianópolis, 2010 / Made available in DSpace on 2012-10-25T01:13:48Z (GMT). No. of bitstreams: 1 281642.pdf: 1233112 bytes, checksum: bd9d08d7868f6136def5e1e21370f98b (MD5) / O presente trabalho descreve o projeto de um pré-amplificador para auxílio à audição em tecnologia CMOS 0.35 ?m. Para tal fim, foi projetado um circuito para processar o sinal em modo corrente, adequado para baixa tensão de alimentação. O pré-amplificador é formado por dois blocos. O primeiro é projetado com um MOS polarizado como resistência, que converte a tensão fornecida pelo microfone em corrente. O segundo bloco processa este sinal de corrente para obter um ganho de 40 dB. O ruído referido à entrada é de 33 ?Vrms e o consumo menor que 12 ?A. A área ocupada pelo pré-amplificador é 0.06 mm2.

Page generated in 0.233 seconds