• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 326
  • 306
  • 44
  • 42
  • 23
  • 6
  • 5
  • 4
  • 3
  • 3
  • 3
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 1121
  • 299
  • 285
  • 189
  • 162
  • 151
  • 117
  • 113
  • 95
  • 95
  • 83
  • 82
  • 78
  • 75
  • 73
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
541

Obtencao e caracterizacao da liga Ti-13Nb-13Zr para aplicacao como biomaterial

SCHNEIDER, SANDRA G. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:45:49Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:08:11Z (GMT). No. of bitstreams: 1 07148.pdf: 8224049 bytes, checksum: ddc36ec3bfc6a15bc7c4dfdb2dfd8abc (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
542

Obtenção de biopolímeros de gelatina por radiação ionizante / Obtention of gelatin biopolymers by ionizing radiation

TAKINAMI, PATRICIA Y.I. 21 January 2015 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2015-01-21T10:28:15Z No. of bitstreams: 0 / Made available in DSpace on 2015-01-21T10:28:15Z (GMT). No. of bitstreams: 0 / Tese (Doutorado em Tecnologia Nuclear) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
543

Estudo de hidroxiapatitas revestidas com poli('epsolon'-caprolactona) estrela: processamento e avalição biológica / Study covered hydroxypatites poly(E-caprolactone) star: processing and biological evaluation

KAIRALLA, ELENI C. 03 March 2015 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2015-03-03T10:44:47Z No. of bitstreams: 0 / Made available in DSpace on 2015-03-03T10:44:48Z (GMT). No. of bitstreams: 0 / Tese (Doutorado em Tecnologia Nuclear) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
544

Implantes cerâmicos e metálicos - caracterização da osteointegração por imuno-histoquímica, lectina-histoquímica e marcadores fluorescentes / Ceramic and metallic implants - osseointegration characterization by immunohistochemistry, lectinhistochemistry and fluorescent markers

VIOLIN, KALAN B. 10 December 2015 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2015-12-10T17:29:01Z No. of bitstreams: 0 / Made available in DSpace on 2015-12-10T17:29:01Z (GMT). No. of bitstreams: 0 / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Tese (Doutorado em Tecnologia Nuclear) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP / FAPESP:10/20698-4
545

Estudo da influência do cobre em ligas ternárias de NiTiCu para utilização em biomateriais. / Study of the influence of copper on NiTiCu ternary alloys for use in biomaterials.

OLIVEIRA, Cláudio Emanuel Silva. 08 March 2018 (has links)
Submitted by Johnny Rodrigues (johnnyrodrigues@ufcg.edu.br) on 2018-03-08T21:00:00Z No. of bitstreams: 1 CLÁUDIO EMANUEL SILVA OLIVEIRA - TESE PPGEQ 2016..pdf: 1522932 bytes, checksum: af3e91fc6bc098f58a808b7fd90cc619 (MD5) / Made available in DSpace on 2018-03-08T21:00:00Z (GMT). No. of bitstreams: 1 CLÁUDIO EMANUEL SILVA OLIVEIRA - TESE PPGEQ 2016..pdf: 1522932 bytes, checksum: af3e91fc6bc098f58a808b7fd90cc619 (MD5) Previous issue date: 2016 / A utilização de ligas de Nitinol (NiTi) são extremamente importantes na fabricação de dispositivos biomédicos, por combinarem as características peculiares dessas ligas metálicas como superelasticidade e efeito memória de forma. Em decorrência da alta concentração do Níquel nas ligas de NiTi, teoricamente é possível a dissolução do Níquel nos líquidos corpóreos em decorrência dos processos de corrosão, podendo ocasionar efeitos indesejados. Os fenômenos de biocompatibilidade e biotoxicidade do NiTi têm sido exaustivamente estudados, visando assim, minimizar os danos da utilização desses materiais. Em decorrência desses estudos, foi proposto neste trabalho de pesquisa a diminuição da concentração do metal Níquel nas ligas de NiTi e a sua substituição pelo metal Cobre, formando assim uma liga metálica de NiTiCu. Foram utilizadas técnicas eletroquímicas para observação da corrosão e as características encontradas em cada liga de NiTiCu com composição diferenciada e compará-las com as de NiTi para uma melhor abordagem do problema e identificação das semelhanças e diferenças percebidas entre as ligas estudadas, além de uma comparação superficial desse material com uso de técnicas de Microscopia Eletrônica de Varredura, Calorimetria Diferencial de Varredura e Microdureza de Vicks. O comportamento eletroquímico das ligas de NiTi e NiTiCu, foram estudadas utilizando de técnicas eletroquímicas de Polarização Linear, Voltametria Cíclica e Impedância Eletroquímica, em dois meios corrosivos Solução de Hanks (sangue artificial) e Solução de Saliva Artificial que se assemelham bastante as condições corpóreas das áreas de utilização desses biomateriais, a uma temperatura ambiente de aproximadamente 25°C, para verificação da durabilidade das ligas metálicas. Observou-se que quanto maior a concentração de Cobre nas ligas de NiTiCu, menos resistente a corrosão esse material terá. Na caracterização superficial, verifica-se que as ligas contendo a menor concentração de Cobre, possuem características superficiais que se assemelham mais com as condições das ligas de NiTi que já são amplamente utilizadas em dispositivos biomédicos. Com a análise de todos os testes eletroquímicos e de caracterização superficial e estrutural das ligas metálicas de NiTiCu e NiTi, verifica-se que as ligas metálicas contendo NiTiCu com pequenos percentuais de Cobre próximo a 5%, possuem características semelhantes as de NiTi, favorecendo a possível utilização dessa liga ternária de NiTiCu para produção de biomateriais para medicina e odontologia, desde que haja estudos mais amplos e interdisciplinares para análises detalhadas referentes a biocompatibilidade, biotoxicidade e de desenvolvimento celular desta nova liga metálica. / The use of Nitinol alloys (NiTi) are extremely important in the manufacture of biomedical devices, for combining the unique characteristics of such alloys and superelasticity and shape memory effect. Due to the high concentration of nickel in alloys of NiTi, it is theoretically possible dissolution of nickel in body fluids as a result of corrosion processes, which may cause unwanted effects. The phenomena of biocompatibility and biotoxicity of NiTi have been thoroughly studied, thus aiming to minimize the damage from the use of these materials. As a result of these studies, it was proposed in this research work to decrease in metal concentration in nickel NiTi alloys and their replacement by copper metal, thereby forming an alloy NiTiCu. Electrochemical techniques were used to observe the corrosion and features found in each league NiTiCu with different composition and compare them with the NiTi for a better approach to the problem and identify the similarities and differences perceived between the studied alloys, as well as a comparison surface of the material with the use of scanning electron microscopy techniques, Differential Scanning Calorimetry and Microhardness of Vicks. The electrochemical behavior of the alloys of NiTi and NiTiCu were studied using electrochemical techniques Linear Polarization, Cyclic Voltammetry and Electrochemical Impedance in two corrosive media Hanks solution (artificial blood) and Solution Saliva Artificial that closely resemble the bodily conditions areas of use of these biomaterials, at an ambient temperature of about 25 ° C to check the durability of metal alloy. It was observed that the higher the concentration of copper in the alloy NiTiCu less corrosion-resistant the material will have. In the superficial characterization, it appears that the alloys containing the lowest concentration of copper, have surface characteristics that are more similar to the conditions of NiTi alloys are widely utilized in biomedical devices. With the analysis of all electrochemical tests and superficial and structural characterization of metal alloys NiTiCu and NiTi, it is found that alloys containing NiTiCu with copper percentages small close to 5%, have similar characteristics of NiTi, favoring possible use of this ternary alloy NiTiCu for the production of biomaterials for medicine and dentistry, provided there is wider and interdisciplinary studies for detailed analysis regarding biocompatibility, biotoxicity and mobile development of this new alloy.
546

Modificação da superfície da liga experimental Ti10Mo8Nb empregando oxidação anódica: estudos in vitro / Surface modification of the esperimental alloy Ti10Mo8Nb employing anodic oxidation: in vitro studies

Carobolante, João Pedro Aquiles [UNESP] 22 February 2017 (has links)
Submitted by João Pedro Aquiles Carobolante null (pedroacarobolante@gmail.com) on 2017-04-03T20:14:27Z No. of bitstreams: 1 Carobolante, J. P. A. - Dissertação.pdf: 4630427 bytes, checksum: a120cbf02bdf37df43d8f9878ea6e209 (MD5) / Approved for entry into archive by Luiz Galeffi (luizgaleffi@gmail.com) on 2017-04-11T20:41:33Z (GMT) No. of bitstreams: 1 carobolante_jpa_me_guara.pdf: 4630427 bytes, checksum: a120cbf02bdf37df43d8f9878ea6e209 (MD5) / Made available in DSpace on 2017-04-11T20:41:33Z (GMT). No. of bitstreams: 1 carobolante_jpa_me_guara.pdf: 4630427 bytes, checksum: a120cbf02bdf37df43d8f9878ea6e209 (MD5) Previous issue date: 2017-02-22 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Titânio e suas ligas são amplamente empregados em aplicações biomédicas, devido a sua biocompatibilidade e excelentes propriedades de volume, como resistência mecânica. As ligas de titânio tipo β com baixo módulo de elasticidade, como Ti10Mo8Nb, são indicadas para amenizar o efeito “stress shielding”, característico da interface implante/osso. No entanto, quando materiais bioinertes são inseridos no corpo humano não induzirão uma resposta específica. As técnicas de modificação de superfície, como crescimento de nanoestruturas de TiO2, são utilizadas para alterar as propriedades de superfície desses materiais permitindo melhor resposta. O objetivo dessa pesquisa é a modificação de superfície da liga experimental Ti10Mo8Nb a partir do crescimento de nanoestruturas de TiO2. Os lingotes da liga experimental Ti10Mo8Nb foram obtidos a partir da fusão dos metais puros em forno a arco voltaico. A oxidação anódica potenciostática foi realizada utilizando um eletrólito formado por glicerina e H2O (1:1, em vol.) com adição de 2,7 % (m/v) de NH4F sob 20 V durante 3 h, a temperatura ambiente. Após o tratamento as amostras foram calcinadas. A superfície da liga foi analisada por microscopia eletrônica de varredura (MEV), difração de raios X (DRX), ângulo de contato, medidas da energia de superfície, espectroscopia de raios X por dispersão em energia (XPS). Estudos in vitro, como adesão celular e bacteriana, foram realizados para avaliar a resposta desse tratamento. A liga Ti10Mo8Nb apresentou fase beta após o processamento, além de diminuição da temperatura β-transus. Após o tratamento de superfície se obteve uma camada nanoporosa de TiO2. As análises in vitro apresentaram viabilidade do crescimento celular e diminuição da proliferação bacteriana. / Titanium and its alloys have been widely used as biomedical material due their biocompatibility and excellent bulk properties, such as mechanical strength. β titanium alloys with low modulus of elasticity, such as Ti10Mo8Nb, are suitable to relieve the stress shielding effect that occurs in the interface implant/bone. However, when these materials are inserted inside human body the surface properties will not induce a specific response. Surface modifications techniques can be used for change the inert surface of these alloys, e.g. TiO2 nanostructure growth by using anodic oxidation. The purpose of this research is the surface modification of Ti10Mo8Nb experimental alloy by using TiO2 nanostruture growth. Ingots of Ti10Mo8Nb experimental alloy were produced by fusion from sheets of molybdenum, niobium and titanium commercially pure in arc melting furnace under argon atmosphere. The potentiostatic anodic oxidation was performed using an electrolyte formed of glycerol and H2O (1: 1 by vol.) with addition of 2.7% (w/v) NH4F under 20 V for 3 h at room temperature. After the surface treatment, the samples were annealing. The surface of the alloy was analyzed by scanning electron microscopy (SEM), X-ray diffraction (XRD), contact angle, surface energy measurements, energy dispersive X-ray spectroscopy (XPS). In vitro studies, such as cell and bacterial adhesion, were performed to evaluate the response of this treatment. The Ti10Mo8Nb alloy exhibited beta phase after the processing, and also occurred a decrease in β-transus temperature. After the surface treatment a nanoporous layer of TiO was obtained. The anatase phase was found in the annealed samples (450 °C for 3 hours). In vitro analyzes showed cell growth viability and decreased bacterial proliferation due to larget specific surface area.
547

Estudo do comportamento em fadiga da liga Ti30Ta após tratamento alcalino e térmico: aplicações biomédicas / Study of fatigue behavior of Ti30Ta alloy after alkaline and heat treatment: biomedical applications

Silva, Kerolene Barboza da [UNESP] 01 August 2017 (has links)
Submitted by Kerolene Barboza da Silva null (kerolene.barboza@gmail.com) on 2017-08-31T17:34:00Z No. of bitstreams: 1 Dissertação Kerolene Barboza da Silva.pdf: 2059319 bytes, checksum: bf04b9b8bef053ca161ff152aa1e7550 (MD5) / Approved for entry into archive by Luiz Galeffi (luizgaleffi@gmail.com) on 2017-09-01T14:32:47Z (GMT) No. of bitstreams: 1 silva_kb_me_guara.pdf: 2059319 bytes, checksum: bf04b9b8bef053ca161ff152aa1e7550 (MD5) / Made available in DSpace on 2017-09-01T14:32:47Z (GMT). No. of bitstreams: 1 silva_kb_me_guara.pdf: 2059319 bytes, checksum: bf04b9b8bef053ca161ff152aa1e7550 (MD5) Previous issue date: 2017-08-01 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Titânio e suas ligas são considerados muito importantes na área médica devido a sua excelente biocompatibilidade e propriedades mecânicas. Nos últimos anos as superfícies dos implantes têm sido estudadas com o objetivo de melhorar suas respostas ósseas, levando há uma tendência de provocar alterações superficiais a fim de acelerar o processo de osseointegração. O tratamento alcalino e térmico é um método típico de modificação da superfície responsável pelo surgimento de uma camada microporosa de óxidos bioativos. No entanto, é importante lembrar que os implantes trabalham sob a ação de carregamentos mecânicos complexos e que, em várias situações, é bastante comum a ocorrência de falhas por fadiga. Visto que, a superfície do implante está sujeita a maiores solicitações que qualquer outra parte, suas características são muito importantes. O objetivo principal da presente pesquisa é estudar a influência da alteração de superfície, por meio da realização do tratamento alcalino e térmico, no comportamento em fadiga da liga Ti30Ta. O trabalho foi iniciado com a fusão dos elementos da liga em forno a arco voltaico em atmosfera de argônio, seguido de tratamento térmico e forjamento rotativo. Para o estudo de fadiga foram confeccionados corpos de provas padrão. A modificação da superfície foi realizada por meio do tratamento alcalino empregando-se solução de NaOH 1,5 M e tratamento térmico. Posteriormente, os corpos de prova foram ensaiados em fadiga. A caracterização utilizou técnicas de microscopia óptica, microscopia eletrônica de varredura, difração de raios X, rugosidade e ângulo de contato. Os resultados obtidos sugerem que a modificação da superfície, dentro das condições realizadas neste estudo, não influenciou no desempenho mecânico da liga Ti30Ta. / Titanium and its alloys are considered very important in the medical area because their excellent biocompatibility and mechanical properties. In recent years surfaces implant have been studied with the goal of improving their bone answers, leading to a tendency to cause superficial changes through the action of chemicals products in order to accelerate the osseointegration process. Alkaline and heat treatment is a typical method of surface modification by surface deposition of bioactive oxides with a porous surface. However it is important to remember that the implants work under the action of complex mechanical loads and the occurrence of failures due to fatigue is quite common in many situations. Since the surface implant is subject to greater demands than any other part, its characteristics are very important. The main goal of this research is to study the influence of modification surface on the fatigue behavior of the Ti30Ta alloy. This work was started with the experimental alloy obtained by melting of the elements in a voltaic arc furnace, heat treatment and cold work. For the fatigue study were prepared specimens. The surface modification was carried out by alkaline treatment using NaOH solution 1,5 M and heat treatment. Later, the specimens were tested in fatigue. The characterization was performed using optical microscopy, scanning electron microscopy, X - ray diffraction, roughness and contact angle. The results obtained suggested that surface modification didn’t affected the Ti30Ta alloy mechanical performance.
548

Influência do zircônio e do oxigênio na estrutura, microestrutura e propriedades mecânicas de ligas do sistema Ti-Mo-Zr / Influence of zirconium and oxygen on the structure, microstructure and mechanical properties of alloys of the Ti-Mo-Zr system

Araújo, Raul Oliveira de [UNESP] 28 August 2017 (has links)
Submitted by Raul Oliveira de Araújo null (raularaujo@fc.unesp.br) on 2017-10-10T19:42:30Z No. of bitstreams: 1 tese_raul.pdf: 7762011 bytes, checksum: 32b91174837e108414bbaeb48b968932 (MD5) / Approved for entry into archive by Luiz Galeffi (luizgaleffi@gmail.com) on 2017-10-11T18:18:16Z (GMT) No. of bitstreams: 1 araujo_ro_dr_bauru.pdf: 7762011 bytes, checksum: 32b91174837e108414bbaeb48b968932 (MD5) / Made available in DSpace on 2017-10-11T18:18:16Z (GMT). No. of bitstreams: 1 araujo_ro_dr_bauru.pdf: 7762011 bytes, checksum: 32b91174837e108414bbaeb48b968932 (MD5) Previous issue date: 2017-08-28 / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Devido a uma série de fatores como o número de acidentes nos esportes, trânsito, doenças como artrite, artrose e osteoporose, a perda das funções biológicas em função do envelhecimento entre outros, acarretam a procura por materiais com a capacidade de cumprir a função de substituir partes ou funções orgânicas do corpo humano. Entre os materiais com a função de substituir tecidos humanos que suportam cargas, estão a classe dos metais, dentre esta classe destacam-se as ligas de Co-Cr, o aço ASTM F138, o titânio puro e a liga Ti-6Al-4V. Porém há a necessidade de ligas que promovam uma melhor compatibilidade mecânica e biológica. Este trabalho visa a preparação e caracterização das ligas Ti-10Mo-xZr (x = 5, 10, 15 e 20 %p), para aplicações como biomaterial. Estas ligas foram submetidas a tratamentos termomecânicos, de laminação à quente, tratamento térmico de recozimento, tratamento térmico de solubilização e tratamento térmicos em atmosfera controlada de oxigênio, para a incorporação deste elemento na liga. As ligas foram caracterizadas quimicamente por espectroscopia de emissão óptica com plasma acoplado indutivamente (ICP-OES), espectroscopia de dispersão de energia (EDS), além de análises de gases e de densidade; caracterizações estruturais e microestruturais por medidas de difração de raios X, refinamento dos difratogramas pelo método de Rietveld, microscopias óptica e eletrônica de varredura; caracterizações mecânicas por microdureza Vickers e módulo de elasticidade e caracterização biológica por ensaios de citotoxicidade in vitro. As ligas apresentaram a estequiometria prevista e boa homogeneidade química. Com relação a estrutura e microestrutura houve a predominância da fase beta a qual aumentou a estabilidade com a concentração de zircônio em detrimento de outras fases como alfa, alfa’’ e ômega. A microdureza diminuiu com o acréscimo do percentual de zircônio (de 451 HV para 372 HV), devido a uma maior estabilidade da fase beta em detrimento das fases secundárias. O mesmo comportamento é verificado em relação ao módulo de elasticidade (de 98 GPa para 77 GPa). Com relação a influência do oxigênio houve aumento na microdureza e módulo de elasticidade com o acréscimo deste elemento. Os testes biológicos não indicaram efeitos citotóxicos. Em se tratando de aplicações biológicas a liga Ti-10Mo-20Zr torna-se a mais promissora por possuir menor módulo de elasticidade em comparação com o aço ASTM F138, Co-Cr, Ti-cp, Ti-6Al-4V e Ti-15Mo. / Due to several factors such as the number of accidents in sports, traffic, diseases like arthritis, osteoporosis, and the loss of biological functions related to aging, among others, lead to a search for materials with the ability to fulfill the function of replacing parts or organic functions of the human body. Among the materials with the function of replacing human tissues that load-bearing, are the class of metals, and among this class are the Co-Cr alloys, the ASTM F138 stainless steel, the pure titanium and the Ti-6Al-4V alloy. However, there is a need for alloys that promote better mechanical and biological compatibility. In this sense, this work aims at the preparation and characterization of the Ti-10Mo-xZr alloys (x = 5, 10, 15 and 20 wt%) for biomaterial applications. These alloys were subjected to several kinds of thermomechanical treatments, such as hot rolling, annealing, solubilization and heat treatment in an oxygen controlled atmosphere, in order to incorporate this element into the alloy. The alloys were chemically characterized by inductively coupled plasma optical emission spectroscopy (ICP-OES), energy dispersive spectroscopy (EDS), in addition to gas and density analyzes. Structural and microstructural characterization were made by X-ray diffraction measurements, with refinement by Rietveld’s method, optical and scanning electron microscopy. Mechanical characterization was made by Vickers microhardness and elastic modulus measurements, and biological characterization was made by in vitro cytotoxicity assays. The alloys presented desirable stoichiometry with good chemical homogeneity. Regarding to structure and microstructure, there is a predominance of  phase, which becomes more stable with the increase in zirconium concentration in detriment of other phases as ’, ’’ and . In this way, the microhardness decreases with the addition of the substitutional element (from 451 HV to 372 HV), due to a higher  phase stability, in detriment of those secondary phases. The same behavior was verified in relation to the elastic modulus (from 98 GPa to 77 GPa). With respect to the influence of oxygen, there is an increase in the values of microhardness and elastic modulus with the addition of this element. Biological tests did not indicate cytotoxic effects. For biological applications, the Ti-10Mo-20Zr alloy becomes the most promising because it has a low astic modulus compared to ASTM F138 stainless steel, Co-Cr, cp-Ti, Ti-6Al-4V and Ti-15Mo alloy. / FAPESP: 2013/09063-5
549

Funcionalização da liga Ti15Zr15Mo após crescimento de nanotubos de TiO2 com recobrimento de quitosana, ácido hialurônico e partículas de ZnO para aplicações biomédicas / Functionalization of the TiO2 nanotube growth in a Ti15Zr15Mo alloy with coating of chitosan, hyaluronic acid and ZnO particles for biomedical applications

Konatu, Reginaldo Toshihiro [UNESP] 06 March 2018 (has links)
Submitted by Reginaldo Toshihiro Konatu (rtkonatu@gmail.com) on 2018-05-03T17:15:41Z No. of bitstreams: 1 Tese KONATU 2018.pdf: 3998865 bytes, checksum: 9ed8e8c75039aad725b37cff903fad84 (MD5) / Rejected by Pamella Benevides Gonçalves null (pamella@feg.unesp.br), reason: Solicitamos que realize correções na submissão seguindo as orientações abaixo: Você realizou duas submissões favor desconsiderar esta. Agradecemos a compreensão. on 2018-05-04T17:53:18Z (GMT) / Submitted by Reginaldo Toshihiro Konatu (rtkonatu@gmail.com) on 2018-05-04T18:50:12Z No. of bitstreams: 1 Tese Konatu 2018.pdf: 4232195 bytes, checksum: e32103c38cfbff0ac3d36adba585b7ad (MD5) / Approved for entry into archive by Pamella Benevides Gonçalves null (pamella@feg.unesp.br) on 2018-05-04T19:25:28Z (GMT) No. of bitstreams: 1 konatu_rt_dr_guara.pdf: 4232195 bytes, checksum: e32103c38cfbff0ac3d36adba585b7ad (MD5) / Made available in DSpace on 2018-05-04T19:25:28Z (GMT). No. of bitstreams: 1 konatu_rt_dr_guara.pdf: 4232195 bytes, checksum: e32103c38cfbff0ac3d36adba585b7ad (MD5) Previous issue date: 2018-03-06 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O presente trabalho tem como objetivo a obtenção de revestimentos poliméricos bactericidas formados por ácido hialurônico/quitosana/ZnO na superfície da liga Ti15Zr15Mo após crescimento de nanotubos de TiO2 empregando oxidação anódica. A liga Ti15Zr15Mo foi processada em forno a arco voltaico com atmosfera controlada e tratados termicamente. Os nanotubos de TiO2 foram obtidos por meio de oxidação anódica. Para obtenção dos revestimentos, as amostras foram recobertas com camadas de ácido hialurônico/quitosana/ZnO. As superfícies foram avaliadas empregando microscopia eletrônica de varredura (MEV), analise por difração de raios-X (DRX), espectroscopia de fotoelétrons excitados por raios-X (XPS) e ângulo de contato. A condição ideal para obtenção dos nanotubos ordenados de TiO2 na superfície da liga foi 30V, eletrólito formado por glicerol, água deionizada (1:1 em volume) e fluoreto de amônio (2,7 g/L) e tempo de 24 horas. Para esses parâmetros, os nanotubos formados apresentaram diâmetro médio de 130 nm e espessura de 1290 nm. O revestimento polimérico escolhido foi de 2 bicamadas de ácido hialurônico/quitosana contendo partículas de ZnO. Os estudos in vitro realizados para avaliar adesão bacteriana de Staphylococcus aureus mostraram que não houve diferença significativa entre as amostras com e sem recobrimento. / Nowadays the development of new materials for biomedical application has become of extreme importance due to the need of new materials with excellent mechanical properties, physicochemical and biocompatibility for use in the manufacture of biomedical devices. In addition to the material presenting the necessary bulk properties, it is of utmost importance that they present a response from the host to the implant. For this, the surface of the material must have characteristics that can be obtained with superficial treatments. This work aims at the analysis of the surface of nanotubes grown on the Ti15zr15Mo alloy functionalized with thin film of hyaluronic acid, chitosan and ZnO nanoparticles. The surface was analyzed by scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS) and contact angle. The nanotubes formed had a mean diameter of 130 nm and a thickness of 1290 nm. The coating with the polymeric bilayers, with a number of more than 4 bilayers, closed the nanotubes and increased the contact angle, being used 2 biacamadas for the incorporation of ZnO. The concentration of the ZnO solution was very low for incorporation and bactericidal effect.
550

Recobrimento de apatitas empregando-se o método biomimético : estudo da influência dos íons K+, Mg2+, SO42- e HCO3- na formação de hidroxiapatita /

Aparecida, Anahí Herrera. January 2006 (has links)
Orientador: Antonio Carlos Guastaldi / Resumo: A atividade biológica do titânio comercialmente puro - Ti c.p. em relação aos tecidos duros é melhorada mediante a modificação de sua superfície empregando-se recobrimento com material bioativo. Um dos materiais bioativos mais utilizados é a Hidroxiapatita - HA, uma das fases das apatitas (fosfatos de cálcio de variadas razões Ca/P), principal constituinte mineral do tecido ósseo. Contudo, além da HA, vários outros fosfatos de cálcio também ocorrem em sistemas biológicos, tais como fosfato de cálcio amorfo - ACP, fosfato octacálcico - OCP e o fosfato tricálcico - TCP, aumentando o interesse nas possibilidades de uso destes materiais como biocerâmicas. Uma técnica de recobrimento muito utilizada nos últimos anos tem sido o Método Biomimético. Seu sucesso deve-se à utilização de uma solução similar ao fluido corpóreo, denominada Synthetic Body Fluid - SBF, que propicia a mimetização do processo biológico realizado para a formação dos tecidos duros. O crescimento da HA e de outras apatitas, tanto no meio biológico quanto em SBF, ocorre em meio contendo, além de íons Ca2+ e PO4 3-, íons-traços essenciais tais como: Mg2+, HCO3 -, K+ e Na+. Alguns destes íons são conhecidos como inibidores do crescimento da HA, como Mg2+ e HCO3 -. Neste trabalho, estudou-se a influência dos íons K+, Mg2+, SO4 2- e HCO3 - na formação de apatitas, principalmente HA, sobre substratos metálicos de Ti c.p. previamente tratados com NaOH 5M. Os efeitos destes íons nos recobrimentos obtidos foram analisados antes e após tratamento térmico a 800ºC por microscopia eletrônica de varredura - MEV, espectroscopia de energia dispersiva de raios X - EDX, difratometria de raios X - DRX e espectroscopia no infravermelho com transformada de Fourier (FTIR). Os resultados mostraram que o crescimento de ACP foi favorecido pela presença dos íons Mg2+ e CO3 2- na solução...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The biological activity of commercially pure titanium - c.p. Ti in relation to hard tissues is improved by modifying its surface using coating with bioactive materials. One of the bioactive materials most used is Hydroxyapatite - HA, one of the phases of the apatites (calcium phosphates of varied Ca/P reasons), main mineral constituent of the bone tissue. However, beyond the HA, several other calcium phosphates also occur in biological systems, such as amorphous calcium phosphate - ACP, octacalcium phosphate - OCP and tricalcium phosphate - TCP, increasing the interest in the possibilities of use of these materials as bioceramics. One technique of coating very used in the last years has been the Biomimetic Method. Its success must it the use of a similar solution to the corporeal fluid, called Synthetic Body Fluid - SBF, that propitiates the imitation of the carried through biological process for the formation of hard tissues. The growth of the HA and other apatites, as much in the biological environment as in aqueous solution as the SBF, occurs environment containing, beyond calcium and phosphate ions, essential ion-traces such as: Mg2+, HCO3-, K+ and Na+. Some of these elements are known as inhibiting of the growth of the HA, as Mg2+ and HCO3-. In this work, it was studied it influence of íons K+, Mg2+, SO42- and HCO3- in the formation of apatites, mainly HA, on metallic substrate of Ti c.p. previously treated with NaOH 5M. The effects of these ions in the obtained coating, before and after the thermal treatment at 800ºC, were analyzed by scanning electron microscopy - SEM, energy dispersive X-rays - EDX, X-ray diffractometer - XRD and Fourier transformation infrared - FT-IR. The results had shown that the growth of ACP was favored by the presence of íons Mg2+ and CO32- in the solution, being also favored its transformation the OCP before the thermal treatment. / Mestre

Page generated in 0.0561 seconds