• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 301
  • 56
  • 10
  • 4
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 425
  • 425
  • 230
  • 136
  • 95
  • 94
  • 92
  • 84
  • 78
  • 75
  • 71
  • 71
  • 71
  • 62
  • 51
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
221

Contribuição ao estudo da aderência de revestimentos de argamassa e chapiscos em substrato de concreto / Contribution to study of the bond strength of mortar renderings and slurry mortars on concrete substrate

Ruduit, Felipe Regert January 2009 (has links)
A grande ocorrência de manifestações patológicas em revestimentos de argamassa associadas à falha de aderência a substratos de concreto cada vez mais chama a atenção do meio técnico, pois além de prejuízos às edificações, pode representar risco aos usuários, motivando diversos trabalhos sobre o assunto. Abordando o problema, a presente dissertação teve como tema a aderência de revestimentos de argamassa à substratos de concreto estrutural. Além da revisão bibliográfica, foram realizadas uma pesquisa em cima de dados de ensaios de resistência de aderência de revestimentos de argamassa em obras e edificações em uso e um programa experimental executado em laboratório. A pesquisa analisou dados obtidos de determinações de resistência de aderência à tração em revestimentos de argamassa de construções e edificações em uso em cidades do Rio Grande do Sul, principalmente na capital Porto Alegre. As informações foram coletadas de ensaios em analogia à NBR 13528 (ABNT, 1995) realizados pelo Departamento de Materiais de Construção Civil da Fundação de Ciência e Tecnologia (CIENTEC/RS) entre 1998 e 2009, totalizando 2616 resultados. Foram correlacionados resistências de aderência, regiões de ruptura e tipos de revestimentos e substratos com o objetivo de analisar as interações destes parâmetros com os resultados de aderência. Entre as constatações destacam-se a aderência dos revestimentos aplicados sobre substratos de concreto estrutural, inferior aos substratos de alvenaria, que apresentaram média de aderência 60 % superior, e a maior ocorrência e menor valor médio de resistência das rupturas na interface concreto/chapisco nos ensaios realizados em revestimentos sobre concreto, resultados que ressaltam a importância do tema abordado e o programa experimental desta dissertação. O experimento realizado em laboratório analisou a influência da cura do chapisco na resistência de aderência de revestimentos de argamassa sobre painéis de concreto utilizando diferentes chapiscos, três convencionais e um industrializado (do tipo adesivo e aplicado com desempenadeira). Dos chapiscos convencionais, dois utilizaram CP IV-32 com traços 1:2 e 1:3 (em volume) e um utilizou CP II-Z e traço 1:3. As camadas de chapisco, logo após sua aplicação, receberam diferentes tratamentos de cura, variando a temperatura do ambiente (23°C e 50°C) e a umidificação das amostras, mantendo-se fixas a umidade do ambiente, os substratos e os revestimentos aplicados após cura dos chapiscos. A resistência de aderência à tração dos revestimentos foi verificada segundo a NBR 13528 (ABNT, 1995). O chapisco industrializado apresentou resistência de aderência 156 % superior à média dos chapiscos convencionais. Entre os chapiscos convencionais, o cimento utilizado mostrou influência significativa na aderência, onde o CP II-Z apresentou resultados superiores ao CP IV. A temperatura de cura também foi significativa nos valores de aderência dos chapiscos, que apresentaram queda significativa de 47,3 % quando curados com temperatura de 50°C. Corpos-de-prova moldados das argamassas de chapisco e curados de forma equivalente aos chapiscos dos painéis foram ensaiados quanto à resistência mecânica e absorção por capilaridade, segundo as NBR’s 13279 e 15259 (ABNT, 2005) respectivamente, onde foram percebidos efeitos significativos da temperatura e tipo de cura e tipo de chapisco nos resultados. / The high occurrence of pathologies in the mortar coverings associated with the failure of adhesion to concrete substrate increasingly catch the attention of technical community, as well as damage to buildings, can pose a hazard to users, resulting in several works on the subject. Approaching the subject, this paper was titled the adhesion of mortar renderings to structural concrete substrates. In addition to the literature review, were conducted a research upon data from tests on bond strength of mortar renderings in works and buildings in use and an experimental program performed in laboratory. The study analyzed data obtained from measurements of bond tensile strength in mortar renderings of constructions and buildings in use in cities of Rio Grande do Sul, mainly in the capital Porto Alegre. Information was collected from tests in analogy to NBR 13528 (ABNT, 1995) conducted by the Department of Construction Material of the Foundation of Science and Technology (CIENTEC/RS) between 1998 and 2009, totaling 2616 results. Resistances were correlated to adherence, regions of rupture and types of renderings and substrates in order to analyze the interactions of these parameters with the bond strength results. Among the findings highlight the adherence of coatings applied to substrates of structural concrete, below the masonry substrates, which showed an average 60% higher, and a higher rate and lower mean resistance of the breaks at the interface concrete/slurry in the trials performed in coatings on concrete, results that accentuate the importance of the theme and the experimental program of this paper. The laboratory experiment examined the influence of slurry mortar curing on the bond strength of mortar renderings on concrete panels using different slurry mortars, three conventional and one industrialized (adhesive type and applied with spattle). Two of conventional mortars used CP IV-32 1:2 and 1:3 volume proportion and one used CP II-Z and 1:3 proportion. Soon after its application, the layer of slurry mortar, received different curing treatments, varying the temperature (23°C and 50°C) and humidification of the samples, keeping fixed the ambient humidity, substrate concretes and renderings applied after slurry curing. The bond tensile strength of renderings was verified according to NBR 13528 (ABNT, 1995). The industrialized slurry mortar presented bond strength 156% higher than the average conventional slurrys. Among conventional mortars, cement used showed significant influence on bond strength, where the CP II-Z showed better results than the CP IV. The curing temperature was also significant in the bond strength values of slurrys, which decreased significantly from 47.3% when cured at 50°C. Specimens of slurry mortars and cured in an equivalent manner to rendered panels were tested for mechanical strength and absorption by capillarity, according to NBR's 13,279 and 15259 (ABNT, 2005) respectively, which were perceived significant effects of temperature and type of curing and type of mortars on the results.
222

Influência da interação entre os parâmetros reológicos de argamassas e a área potencial de contato de substratos na aderência de argamassas de revestimento / Interaction between mortar rheological parameters and surface potential contact area on mortar renderings bond strength

Stolz, Carina Mariane January 2011 (has links)
A falta de controle tecnológico e conhecimento técnico na produção de argamassas resultam muitas vezes no aparecimento de manifestações patológicas, o que compromete o adequado cumprimento de suas principais funções: proteção, estanqueidade e acabamento estético das edificações. Buscando-se um melhor entendimento dos parâmetros que influenciam na resistência de aderência à tração e ao cisalhamento dos revestimentos argamassados aos substratos de concreto, o principal objetivo desta pesquisa consiste em verificar a influência da interação entre a área potencial de contato do substrato e a reologia das argamassas de revestimento no desempenho quanto a estas propriedades. Ainda, verificou-se a influência das propriedades reológicas das argamassas afetadas pelo teor de aditivo incorporador de ar na resistência de aderência à tração e ao cisalhamento de revestimentos argamassados, bem como o controle da rugosidade durante a confecção de substratos de concreto, proporcionando um aumento da área potencial de contato da argamassa de revestimento assentada sobre ele, visando melhorar o desempenho do revestimento quanto à resistência de aderência à tração e ao cisalhamento. Para que fosse possível alcançar estes objetivos foram realizados procedimentos laboratoriais que compreenderam a moldagem de prismas de concreto, com resistência à compressão de 35MPa, de 25x35x5cm, sobre placas de borracha que estamparam três diferentes tipos de rugosidades em suas superfícies. Sobre estes prismas, foram assentadas três diferentes tipos de argamassas de proporcionamento 1:1:4 (cimento:cal hidratada:areia, em volume, material seco), variando-se o comportamento reológico destas através de diferentes adições de aditivo incorporador de ar. Este assentamento ocorreu com o uso de caixa de queda, visando uma maior uniformidade da energia de aplicação. Para analisar as diferentes características reológicas das argamassas foram realizados ensaios de caracterização no estado fresco e endurecido conforme as normas vigentes. Os substratos de concreto foram caracterizados quanto à sua rugosidade com Scanner 3D a laser, além de ensaios de controle tecnológico. Ao final desta pesquisa pode-se concluir que nem sempre um acréscimo da área de contato proporcionado pela rugosidade do substrato é sinônimo de aumento da extensão de aderência e consequentemente da resistência de aderência. A reologia da argamassa possui grande influência sobre estes fatores, sendo essencial uma compatibilidade entre rugosidade do substrato e reologia das argamassas para que se tenha um incremento na resistência de aderência dos revestimentos ao substrato. / and the shear bond strength of mortar rendering applied to concrete surfaces, this work intended to verify the influence of the interaction between surface potential contact area and mortar renderings’ rheology on these performance properties. Moreover, this work has the objective to verify the influence of the mortar’s rheology affected by the air-entraining agents in bond strength and the concrete surface roughness control in this property. In this study, three different pre-defined surface roughnesses were stamped with rubber plates (25x35x5cm) in a concrete mold then concrete prisms were molded. The surface concrete has a fix compressive strength of 35MPa. Three mortars with the 1:1:4 (cement: hydrated lime:sand, in volume, dry material) mix proportion, changing the air-entraining proportion to modify the rheology behavior were placed on these concrete surfaces, using a drop box for mortars. Tests of tensile bond strength (Ra), according to the requirements of Brazilian Standard - NBR 13528 (2010) and shear bond strength (Rc) had been carried out with these samples. Additionally characterization tests in fresh and hardened mortars had been done. The surfaces roughnesses were characterized by a 3D laser scanner and by technologic tests control. The results indicated that the increasing of the surface contact area is not an indicative that the bond strength will also increase. The mortar’s rheology has a very important influence in these factors, and it is essential the compatibility of the system to rise the contact area and consequently the bond strength.
223

Avaliação da microdureza dentinária, resistência de união e profundidade de penetração do cimento obturador à dentina radicular após irrigação final com solução de quitosana: estudo ex-vivo, por meio do teste mecânico \"push out\" e microscopia confocal a laser / Evaluation of root dentin microhardness, bond strength and sealer penetration depth after final irrigation with chitosan solution: an ex-vivo study, through \"push out\" mechanical test and laser confocal microscopy

Polliana Vilaça Silva Antunes 05 November 2015 (has links)
O presente estudo teve como objetivo avaliar, por meio da análise da microdureza dentinária, teste push-out e microscopia confocal a laser, a influência da irrigação final do canal radicular com quitosana 0,2% e EDTA 15% sobre a adesão e penetração do cimento endodôntico através dos túbulos dentinários. Selecionaram-se 50 caninos superiores humanos, os quais após a remoção das coroas foram instrumentados com Reciproc® e hipoclorito de sódio 1%. Os espécimes foram distribuídos em 5 grupos (n=10), conforme protocolo de irrigação final: G1- irrigação convencional com EDTA 15%; G2- EndoVac com EDTA 15%; G3- irrigação convencional com quitosana 0,2%; G4- EndoVac com quitosana 0,2%; G5- grupo controle (sem irrigação final). As raízes foram obturadas pela técnica da condensação lateral com AH Plus e seccionadas transversalmente. O primeiro slice de cada terço foi destinado à resistência de união por cisalhamento por extrusão (RU), e o segundo slice às análises de microdureza dentinária e microscopia confocal a laser. Os dados obtidos foram submetidos à análise estatística descritiva com números absolutos, médias e desvios-padrões e análise de variância de Kruskal-Wallis seguido de teste de Tukey, com significância de 5%. Os resultados mostraram que em todos os grupos houve redução da microdureza dentinária de forma significantemente diferente ao controle (p=0,001). Na comparação intragrupos entre G1, G2 e G3 a penetração de cimento endodôntico no terço cervical foi maior que no apical (p<0,005). No G4 não houve diferença significante entre os três terços (p=0,481). Para a RU, considerando os terços cervical e apical, houve semelhança entre todos os protocolos de irrigação, sendo esses diferentes estatisticamente do grupo controle (p<0,001). Em geral, a resistência de união observada no terço cervical foi estatisticamente superior aos demais terços (p<0,001). No terço cervical dos espécimes em geral, houve predominância de falhas mistas (55,4%) e de falhas adesivas à obturação nos terços médio (58,8%) e apical (56,8%). Concluiu-se que o uso das soluções estudadas, independentemente do protocolo, reduziram a microdureza nos três terços radiculares, favoreceram a penetração do cimento através dos túbulos e aumentaram a adesão do cimento às paredes dentinárias em relação ao controle. / This study aimed to assess, through dentin hardness analysis, push-out tests and laser confocal microscopy, the influence of root canal final irrigation with 0.2% chitosan and 15% EDTA among endodontic cement adhesion and penetration through the dentinal tubules. Fifty human upper canines were selected. After crowns cut off and removal, roots were instrumented with Reciproc® and 1% sodium hypochlorite. The specimens were divided into 5 groups (n = 10) according to final irrigation protocol: G1- conventional irrigation with 15% EDTA; G2-EndoVac use + 15% EDTA; G3- conventional irrigation with 0.2% chitosan; G4-EndoVac use with 0.2% chitosan; G5- control group (without final irrigation). Roots were filled by lateral condensation technique with AH Plus and sectioned transversely. The first slice of each third was reserved for bond strength shear extrusion (SE) tests, and the second slice for dentin microhardness and laser confocal microscopy analysis. Data were submitted to descriptive statistical analysis with absolute numbers, means, standard deviations and Kruskal-Wallis variance analysis followed by Tukey\'s test. A significance level of 5% was considered. Results showed that in all groups there was a reduction in dentin microhardness, with significantly difference if compared with the control group (p=0.001). In intra-groups comparisons between G1, G2 and G3, cervical third sealer penetration was higher than apical third (p<0.005). In the G4 there was no significant difference between thirds (p=0.481). In the SE cervical and apical thirds comparisons, showed to be similar among all irrigation protocols, with statistically difference from the control group (p<0.001). The bond strength observed in the cervical third was statistically higher to the other thirds (p<0.001). In specimens cervical third, there was a predominance of mixed failures (55.4%) and adhesive failures on obturation in the middle (58.8%) and apical (56.8%) thirds. It can be concluded that regardless of the protocol, the studied solutions reduced the microhardness in the three root thirds, favored tubules cement penetration and increased dentin walls cement adhesion if compared to the control group.
224

Avaliação da resistência da união de cimentos obturadores resinosos à dentina radicular, por meio do teste push-out acoplado ao microtomógrafo / Evaluation of bond strength of resin-based sealers to radicular dentin by push-out test coupled to a microtomography

Manoel Brito Júnior 05 December 2014 (has links)
O objetivo deste estudo foi avaliar a resistência de união à dentina da obturação de canais radiculares com cimentos à base de resina epóxica e de metacrilato, por meio do dispositivo material testing stage (MTS) acoplado ao microtomógrafo (&mu;CT), bem como avaliar qualitativamente a ruptura da massa obturadora por meio de imagens de &mu;CT. Além disso, foram utilizados o método de elementos finitos 3D e microscopia confocal de varredura a laser (MCVL) para verificar, respectivamente, a distribuição de tensões e presença de gaps na interface de união. Raízes de caninos superiores com 17 mm de comprimento foram submetidas ao preparo biomecânico com instrumentos rotatórios de níquel titânio, sob irrigação constante com NaOCl 1% e irrigação final com EDTA 17%. Os canais foram obturados pela técnica da condensação lateral com cones de guta percha e os cimentos: AH Plus, Epiphany SE ou RealSeal XT. As raízes foram armazenadas (100% de umidade, 37°C) por três vezes o tempo de endurecimento do cimento utilizado. Após este período, as raízes foram seccionadas para obtenção de dois slices (2 mm) de cada terço radicular. Um slices de cada terço foi submetido ao teste de push-out através de dispositivo mecânico MTS acoplado ao &mu;CT SkyScan 1174 (50kV, 80mA). Após o escaneamento inicial do slices, com resolução isotrópica de 13 &mu;m, filtro de 0.5 mm de Al e 360º de rotação, o teste mecânico foi iniciado até que ocorresse o deslocamento do material. Novo escaneamento foi realizado com os mesmos parâmetros iniciais, que determinou regiões de ruptura da massa obturadora em secções axiais. Os tipos de falhas foram avaliados por MCVL e classificadas em: adesivas, coesivas e mistas. Modelos 3D de elementos finitos foram gerados para os terços cervical, médio e apical, a partir de imagens de &mu;CT. No segundo slices de cada terço radicular, foi aferido o percentual de gaps do material obturador às paredes do canal radicular, por meio de MCVL e do programa OLS 4000. Os dados foram analisados por testes estatísticos paramétricos e não paramétricos (p<0,05). O cimento AH Plus [1,89 (1,01/2,39) MPa] apresentou maior resistência de união à dentina (p<0,001) quando comparado aos cimentos Epiphany SE [0,36 (0,29/0,44) MPa] e RealSeal XT [0,43 (0,32/0,54) MPa]. Para os cimentos AH Plus e RealSeal XT, os terços cervical e médio apresentaram maior resistência de união à dentina que o terço apical (p<0,001). As rupturas ocorreram nas margens da massa obturadora para o cimento AH Plus, enquanto os cimentos Epiphany SE e RealSeal XT tiveram este tipo de ruptura, bem como na própria massa obturadora. No cimento AH Plus, a interface de união mostrou maior concentração de tensões, que foram distribuídas principalmente na massa obturadora para os cimentos Epiphany SE e RealSeal XT. Houve predominância de falhas adesivas e mistas em todos os cimentos. Em relação ao percentual de gaps, o cimento AH Plus apresentou as menores médias (11,14% ± 4,03), com diferença estatisticamente significante (p<0,05) dos cimentos Epiphany SE (55,39% ± 13,46) e RealSeal XT (62,50% ± 6,72). O cimento à base de resina epóxica (AH Plus) apresentou a maior resistência de união à dentina e teve comportamento diferente em relação aos outros cimentos, quanto à ruptura da massa obturadora e distribuição de tensão interfacial. Além disso, o cimento AH Plus apresentou o menor percentual de gaps entre o material obturador e as paredes do canal radicular / The aim of this study was to evaluate the bond strength of epoxy resin- and methacrylate-based sealers to root dentin, using the material testing stage (MTS) coupled to a micro-computed tomography (&mu;CT) device and to qualitatively assess the root-filling mass rupture by &mu;CT images. Additional analyses were conducted using the 3D element finite method and confocal laser scanning microscopy (CLSM) to verify, respectively, the stress distribution and percentage of gaps on dentin filling material interfaces. Maxillary canine roots measuring 17 mm were subjected to biomechanical preparation with nickel-titanium rotary instruments under constant irrigation with 1% NaOCl and final irrigation with 17% EDTA. Canals were filled by the lateral condensation technique with gutta-percha cones and the following sealers: AH Plus, Epiphany SE or RealSeal XT. The roots were stored (100% humidity, 37 °C) for a period three times longer than the setting time required for each sealer and then sectioned transversally to obtain two 2-mm-thick slices from each root third. One slice of each third was subjected to the push-out test using the MTS coupled to the SkyScan 1174 &mu;CT (50 kV, 80 mA) with 13 &mu;m isotropic resolution, 0.5 mm Al filter and 360° rotation. After the initial scanning of the slice, the mechanical test was performed until material dislodgement occurred. A new scanning was performed using the same initial parameters. The axial sections obtained were used for qualitative evaluation of the root-filling mass rupture. Failure modes were assessed by CLSM and classified as adhesive, cohesive or mixed. 3D &mu;CT based finite element models were generated from cervical, middle and apical root thirds to simulate the push-out test. The second slice of each root third was used to assess the percentage of gaps between the filling material and the root canal walls, using CLSM with the aid of the OLS 4000 software. The data were analyzed by parametric and non-parametric tests (p<0.05). AH Plus presented higher bond strength [1.89 (1.01/2.39) MPa] to dentin (p<0.001) than Epiphany SE [0.36 (0.29/0.44) MPa] and RealSeal XT [0.43 (0.32/0.54) MPa]. For AH Plus and RealSeal XT sealers, the cervical and middle thirds showed higher bond strength to dentin than the apical third (p <0.001). The ruptures occurred in the margins of the root filling mass for AH Plus, while Epiphany SE and RealSeal XT had this type of rupture as well as in the root filling mass itself. AH Plus showed stress concentration on bond interface, while in Epiphany SE and RealSeal XT the stress was mainly distributed on the root-filling mass. Adhesive and mixed failures were the predominant fracture modes in all sealers. Regarding the percentage of gaps between the filling material and the root canal walls, AH Plus presented the lowest means (11.14%±4.03), differing significantly (p<0.05) from Epiphany SE (55.39%±13.46) and RealSeal XT (62.50%±6.72) sealers. The epoxy resin-based sealer (AH Plus) presented the highest bond strength to dentin, which had different behavior from other sealers regarding root-filling mass rupture and interfacial stress distribution. Moreover, AH Plus resulted in the lowest percentage of gaps between the material and the root canal walls
225

Efeito do tempo de condicionamento na degradação da união resina-dentina decídua

Sanabe, Mariane Emi [UNESP] 28 February 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:47Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-02-28Bitstream added on 2014-06-13T20:17:11Z : No. of bitstreams: 1 sanabe_me_me_arafo.pdf: 801888 bytes, checksum: c29d9fba1c2e1a1219458d7df6abd318 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / O presente estudo teve como objetivo investigar o efeito da redução do tempo de condicionamento da dentina decídua na resistência de união imediata de um sistema convencional e um autocondicionante, e na degradação da união resina-dentina após 6 meses de armazenagem em água. Foram utilizados quarenta e oito molares decíduos hígidos foram aleatoriamente divididos em 4 grupos (n=12) de acordo com o sistema adesivo (Adper Single Bond e Clearfil SE Bond) e o tempo de condicionamento da dentina (como recomendado pelo fabricante e metade desse tempo). Desta forma, o sistema Single Bond foi aplicado sobre a dentina condicionada com ácido fosfórico a 35% por 15 ou 7 segundos, enquanto que o sistema Clearfil SE Bond foi aplicado à dentina condicionada com SE Primer por 20 ou 10 segundos. Em seguida, coroas em resina composta foram reconstruídas incrementalmente e os dentes foram mantidos hidratados em estufa à 37o C por 24 horas. Dez dentes de cada grupo foram utilizados para o ensaio mecânico de microtração. Os demais foram preparados para análise da interface adesiva em MEV. Espécimes em forma de pilar de secção transversal quadrangular (0,49 mm2) foram obtidos e divididos de acordo com a condição de armazenagem, 24 horas em água (controle), 6 meses em água e 6 meses em óleo. Os espécimes foram tracionados a velocidade de 0,5 mm/min em máquina de ensaios mecânicos e as fraturas classificadas em adesiva, coesiva em dentina, coesiva em resina ou mista. Os dados foram analisados estatisticamente pela análise de variância e testes complementares de comparação múltipla, considerando-se o nível de significância de 5%. Após 24 horas de armazenagem, os sistemas adesivos apresentaram valores de resistência de união comparáveis estatisticamente, não influenciados pela redução do tempo de condicionamento ácido... . / To evaluate the effect of reducing the acid etching of primary dentin on the immediate bond strength of a conventional and a self-etching primer system, and on the degradation of the resin-dentin bonds after 6 months aging. Forty-eight sound primary molars were randomly divided into 4 groups of investigation (n=12) according to the adhesive system (Adper Single Bond and Clearfil SE Bond) and the period of acid etching (as recommended by the manufacturers and half of this time). Single Bond was applied to dentin after 35% phosphoric acid etching for 15 seconds or 7 seconds, whereas Clearfil SE Bond was applied to dentin after the application of SE Primer for 20 seconds or 10 seconds. Following the adhesive systems, composite resin crowns were incrementally built-up and the teeth were stored in water at 37o C for 24 hours. Specimens with a cross-sectional area of 0,49 mm2 were produced from each one of the teeth (10 teeth per group) and further divided according to the storage condition, 24 hours in water, 6 months in water and 6 months in mineral oil, when they were tested under tension until failure in a machine operating at a cross-head speed of 0.5 mm/min. After the microtensile test, the failures were classified as adhesive, cohesive in dentin, cohesive in resin or mixed. The two remaining teeth per group were prepared to SEM evaluation of the interfaces. Two-way analysis of variance and multiple comparison testes were applied at a significance level of 5%. When bond strength was evaluated after 24 hours storage in water there was no significant difference between the adhesive systems, irrespective of the periods of acid etching. For Single Bond, water storage for 6 months in water significantly reduced bond strength, especially when the dentin was phosphoric acid conditioned for 15 seconds (36.7% reduction). For Clearfil SE Bond... (Complete abstract, click electronic address below).
226

EFEITO DO CONDICIONAMENTO COM DIFERENTES CONCENTRAÇÕES DE ÁCIDO FLUORÍDRICO NA ADESÃO E NA RESISTÊNCIA À FLEXÃO DE UMA CERÂMICA FELDSPÁTICA / EFFECT OF ETCHING WITH DIFFERENT CONCENTRATIONS OF HYDROFLUORIC ACID ON THE ADHESION AND THE FLEXURAL STRENGTH OF A FELDSPATHIC CERAMIC

Venturini, Andressa Borin 06 August 2014 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Purpose: To evaluate the effect of different hydrofluoric (HF) acid concentrations in the contact angle and in the durability of bond strength between feldspathic ceramic and resin cement, as well as the impact on the roughness and flexural strength of this ceramic. Materials and Methods: Twenty-five ceramic blocks (VitaBlocks Mark II) (12 x 10 x 2.4 mm) were produced for contact angle analysis, 40 ceramic blocks (12 x 10 x 4 mm) for microtensile bond strength (MTBS), and 150 ceramic barshaped specimens (14 x 4 x 1.2 mm) to evaluate the roughness and flexural strength. Specimens were randomly divided into 5 groups, excluding the control group for MTBS: SC (control) - no ceramic surface treatment; etching with HF acid 1% (HF1), 3% (HF3), 5% (HF5) and 10% (HF10) for 60. The contact angle measurements were performed on a Goniometer and the MTBS test in a universal testing machine. All bar-shaped specimens were analyzed in a profilometry and loaded to failure using a 3-point bending test. Data were submitted to statistical analysis. Results: SC had the highest contact angle (61.4°± 5°), whereas HF10 showed the lowest value (17.5° ± 4°). In dry conditions, different HF acid concentrations promoted similar bond strength statistically (14.2 to 15.7 MPa) (p<0.05), but when the specimens were aged, only the bond from the HF1 group decreased statistically (14.5 to 10.2 MPa). All groups produced significantly rougher surfaces than the control group (SC) (p<0.05). However, the mean flexural strength values were not statistically different among the etched groups (106.47 to 102.02 MPa). Conclusion: In terms of adhesion, the tested ceramic can be etched with HF acid in concentrations of 3%, 5% and 10%. Different acid concentrations did not affect the flexural strength of the tested ceramic. Acid etching appear to have a weakening effect on the ceramic surface, if compared to the untreated group. / Objetivo: Avaliar o efeito de diferentes concentrações de ácido fluorídrico (HF) no ângulo de contato e na durabilidade da resistência adesiva entre uma cerâmica feldspática e um cimento resinoso, bem como o impacto sobre a rugosidade e resistência à flexão desta cerâmica. Materiais e Métodos: Vinte e cinco blocos cerâmicos (VitaBlocks Mark II) (12 x 10 x 2.4 mm) foram produzidos para a análise do ângulo de contato, 40 blocos cerâmicos (12 x 10 x 4 mm) para resistência de união à microtração (MTBS) e 150 espécimes em forma de barra de cerâmica (14 x 4 x 1,2 mm) para avaliar rugosidade e resistência à flexão. Os espécimes foram divididos aleatoriamente em 5 grupos, excluindo o grupo controle para MTBS: SC (controle) - sem tratamento da superfície cerâmica; condicionamento com ácido HF 1% (HF1), 3% (HF3), 5% (HF5) ou 10% (HF10) por 60 s. As medidas de ângulo de contato foram realizadas no Goniômetro e o teste MTBS em uma máquina de ensaio universal, sendo metade dos espécimes de cada bloco testados imediatamente e a outra metade submetida à armazenagem/termociclagem. Todas as amostras em forma de barra foram analisadas em um rugosímetro e carregadas até a falha usando um teste de flexão de três pontos. Os dados foram submetidos à análise estatística. Resultados: SC obteve o maior ângulo de contato (61,4° ± 5°), enquanto que HF10 apresentou o menor valor (17,5° ± 4°). Em condições secas, diferentes concentrações de ácido HF promoveram resistências adesivas estatisticamente semelhantes (14,2-15,7 MPa) (p<0,05), mas quando os espécimes foram envelhecidos, apenas a adesão do grupo HF1 reduziu estatisticamente (14,5-10,2 MPa). Todos os grupos produziram superfícies significativamente mais rugosas do que o grupo controle (SC) (p<0,05). No entanto, os valores médios de resistência à flexão não foram estatisticamente diferentes entre os grupos condicionados (106,47- 102,02 MPa). Conclusão: Em termos de adesão, a cerâmica testada pode ser condicionada com ácido HF em concentrações de 3%, 5% ou 10%. As diferentes concentrações de ácido não afetaram a resistência à flexão da cerâmica testada. O condicionamento ácido parece ter um efeito de enfraquecimento sobre a superfície cerâmica, se comparado com o grupo não tratado.
227

Avaliação da resistência ao cisalhamento de reparos de resina : interface tratada com laser de Er Yag, ponta diamantada e jato abrasivo com óxido de alumínio /

Rossato, Desirée Mory. January 2004 (has links)
Resumo: O objetivo deste trabalho foi realizar avaliação da resistên - cia de união ao cisalhamento de reparos de resina compostas em restaurações com resina composta envelhecidas, em função de diferentes tratamentos superficiais. Foram confeccionados 60 corpos-de-prova de resina composta Z250 (3M) e levados a termociclagem para simular o envelhecimento da restauração, foram realizados 500 ciclos de 15 segundos cada, variando entre 5°e 55°C. Separados aleatoriamente em seis grupos que sofreram os seguintes tratamentos superficiais: nenhum tratamento (G1 - controle), desgaste com ponta diamantada (G2), jato de óxido de alumínio com partículas de 27,5æm (G3) por 10 segundos, laser de Er:YAG - 200mJ (G4), laser de Er:YAG - 300mJ (G4) e laser de Er:YAG - 400mJ (G6), os três últimos com freqüência de 10Hz por 10 segundo. Foi realizada microscopia eletrônica de varredura para observarmos o aspecto do material após os tratamentos terem sido executados. O reparo da restauração foi realizado utilizando-se a mesma resina. O teste de cisalhamento foi feito na Máquina de Ensaios Mecânicos MTS - 810. Analisando os resultados por ANOVA e pelo teste de Tukey não foram encontradas diferenças significativas (p-valor=0.5120). A análise dos valores medianos, mostrou que o tratamento superficial com jato de óxido de alumínio apresentou uma maior resistência da interface do reparo ao cisalhamento (8.91Mpa) enquanto que o laser de Er:YAG com 400mJ de potência, apresentou a menor (6.76Mpa). A análise dos tipos de fratura mostrou que 90% dos corpos-de-prova do grupo 3 (óxido de alumínio) sofreram fraturas coesivas. / Abstract: The aim of this work was to perform the evaluation of the shear bond strength of the composite resin repairs in old composite restorations, modifying the superficial treatment of the samples. Sixty samples of the composite resin Z250 (3M) were prepared and thermocycled for 500 cycles at 5° and 55°C with a dwelling time of 15 seconds. Speciments were randomly divided into six groups and subjected to different surface treatments as follows: No surface treatment (G1 - control), grinding with a diamond bur (G2), sandblasting with a microetcher for 10 seconds with 27,5æm Al2O3 particles (G3), treated with Er:YAG laser with an energy intensity of 200mJ (G4), 300mJ (G5), 400mJ (G6), frequency of 10Hz for 10 seconds. The speciments after surface treatment were observed using the scanning electron microscope. The repair of the old resin was done with the same material. The shear bond strength test was performed in a Mechanic Testing MTS - 810. Statistical treatment by ANOVA and Tukey's test showed no significant differences between the groups tested (p=0.5120). The highest shear bond strength values were achieved by sandblasting the surface with a microetcher with Al2O3 (8,91Mpa), whereas the lowest values were obtained with Er:YAG laser with energy intensity of 400mJ (6.76Mpa). Observing the rupture surface, G3 presented 90% of cohesive failures. / Orientador: José Roberto Cury Saad / Coorientador: Rosane F. Z. Lizarelli / Banca: Celso Luiz de Angelis Porto / Banca: Elda Pisaneschi / Mestre
228

Resistência de união da resina composta à dentina irradiada com laser de Nd:YAG, utilizando o teste de microtração /

Castro, Fabrício Luscino Alves de. January 2004 (has links)
Orientador: Marcelo Ferrarezi de Andrade / Banca: Maria Salete Machado Cândido / Banca: Luís Geraldo Vaz / Banca: Paulo Sérgio Quagliatto / Banca: Marcela Rocha de Oliveira Carrilho / Resumo: Este estudo avaliou, por meio do teste de microtração, a resistência de união da resina composta à dentina, verificando a influência da irradiação do tecido com laser de Nd:YAG, realizada após a aplicação do adesivo, e associada ou não ao pré-tratamento ácido do mesmo. Superfícies dentinárias planas foram criadas em 37 terceiros molares humanos extraídos, dos quais, 36 foram selecionados para teste. Os adesivos Single Bond (SB) e Clearfil SE Bond (CSEB) foram aplicados, com ou sem o condicionamento da dentina (ácido fosfórico para o SB e "primer" auto-condicionante para o CSEB). Após aplicação dos adesivos e antes de sua fotopolimerização, as superfícies foram irradiadas com laser, exceto para os controles, testando-se duas potências, 0,75 e 1W. No total, 12 grupos foram criados, 6 para cada sistema. Coroas de resina composta foram construídas e os dentes armazenados a 37ºC por 24h. Depois, os mesmos foram cortados serialmente, resultando em espécimes com secção transversal de união aproximada de 0,49mm2, que foram, em seguida, testados sob tração. Espécimes fraturados, representativos dos diferentes grupos, tiveram suas superfícies dentinárias observadas ao microscópio eletrônico de varredura (MEV). As interfaces adesivas de 2 espécimes não testados em cada grupo também foram observadas ao MEV. O sistema SB foi aplicado na superfície do dente remanescente (sem ácido e sem laser), a coroa de resina construída e o conjunto seccionado em duas metades, para observação da interface ao MEV. Os resultados mostraram que a aplicação do laser aumentou a resistência à microtração apenas quando o SB foi aplicado sem o condicionamento ácido prévio e em relação ao grupo em que só o adesivo foi aplicado (SB / sem ácido/ sem laser). Entretanto, estes valores foram inferiores aos obtidos quando o SB foi... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study evaluated if the irradiation of dentin trough the adhesive applied on it affected micro-tensile bond strength of composite to this tissue. Flat dentin surfaces were created in 37 extracted human third molars. Thirty-six teeth were selected and received surface treatments. Single Bond (SB) and Clearfil SE Bond (CSEB) systems were individually applied after dentin had been acid-etched or not, with phosphoric acid for SB or self-etching primer for CSEB. Immediately after adhesives application and before light curing, surfaces were lased, except for controls, using two power settings, 0.75 and 1W. So, 12 groups were designed, 6 for each bonding system. After that, composite crowns were built-up over the treated surfaces and the teeth were stored in distillated water, at 37ºC, for 24h. The teeth were serially sectioned in beams with cross-sectional area of approximately 0,49mm2, and the specimens were stressed to failure under tension using a testing machine. Representative fractured specimens were selected and had their dentin surfaces observed under scanning electron microscopy (SEM). Interfaces of two untested beams were also observed under SEM. Moreover, the dentin surface of one additional tooth received SB application (with neither acid etching nor laser irradiation), a composite crown was built-up on it and the tooth was cut longitudinally in two halves, which had their dentin/resin interfaces observed under SEM. This study showed that laser irradiation increased micro-tensile bond strength only in Groups 5 and 6, where SB was applied without previous dentin acid etching, in comparison to the group where this adhesive was used alone (Group 4 - no etching / no laser). However, these values were lower than those found when dentin was etched. There was not an improvement in bond... (Complete abstract, click electronic address below) / Doutor
229

Efeito de material cimentante e do tempo na resistência adesiva de pinos de fibra de vidro /

Campos, Leonardo Maciel. January 2007 (has links)
Orientador: Maria Salete Machado Candido / Banca: Abraham Lincoln Calixto / Banca: Luiz Alberto Plácido Penna / Banca: José Roberto Cury Saad / Banca: Marcelo Ferrarezi de Andrade / Resumo: O objetivo desse estudo foi avaliar in vitro a resistência à tração de pinos de fibra de vidro cimentados em raízes de dentes bovinos com quatro agentes cimentantes em dois períodos de tempo de armazenamento em saliva artificial: com 48 horas e após 240 dias. Para tal, foram utilizadas 80 raízes de dentes bovinos que, após tratamento endodôntico, foram divididas em 8 grupos com 10 raízes para cada grupo. Para a fixação dos pinos foram utilizados 4 diferentes agentes cimentantes sendo que, os quatro primeiros grupos foram armazenados em saliva artificial por 48 horas antes do teste de tração; a saber: Grupo I - cimento resinoso dual (Rely X e Adper Single Bond-3M/ESPE), Grupo II - cimento de ionômero de vidro (Bioglass "C"- BIODINÂMICA), Grupo III - cimento de fosfato de zinco (SS WHITE), Grupo IV - cimento resinoso quimicamente ativado (CB Cement e One-Step/ BISCO). Os outros 4 Grupos (V, VI, VII e VIII) receberam os mesmos agentes cimentantes citados acima e na mesma seqüência porém, armazenados em saliva artificial por 240 dias antes da realização do teste de resistência à tração em uma Máquina de Ensaio Universal (VERSAT 500) à velocidade de deslocamento de 1,0 mm/min. Os dados foram catalogados e submetidos à análise estatística mediante os testes Análise de Variância, Tukey e t-student. Os resultados mostraram após 48 horas de armazenamento, o comportamento dos Grupos em estudo e podem assim ser representados: G IV > G III > G I > G II, no entanto, após 240 dias: G VIII = G VII  G VI  G V; concluindo que: a resistência à tração de pinos de fibra de vidro; cimentada em raízes bovina, foi influenciada com o tempo, pois, quanto maior o tempo de envelhecimento, menor é o valor da resistência, com exceção do cimento de ionômero de vidro. / Abstract: The purpose of the present investigation was to assess the in vitro tensile bond strength resistence of fiberglass posts retained with different cementing agents in bovine teeth at different time points, upon incubation with artificial saliva. To that end, eighty roots harvested from bovine teeth received endodontic treatment and were split into 8 groups (10 roots per group). The fiberglass posts were retained with four different cementing agents, and the first groups were incubated with artificial saliva 48 hours before the tensile test. The groups were distributed as follows: Group I - dual resin cement (Rely X e Adper Single Bond-3M/ESPE), Group II - glass ionomer cement (Bioglass "C"- BIODINÂMICA), Group III - zinc phosphate cement (SS WHITE) and Group IV - chemically activated resin cement (C&B Cement e One -Step/BISCO). The remaining four groups (V, VI, VII and VIII) were accordingly treated with the same cementing agents and conditions, except for the fact that they were incubated with artificial saliva for 240 days before being subjected to the tensile test using a Universal Testing Machine (VERSAT 500) at 1.0 mm/min. The data generated were collected and subjected to statistical analysis through ANOVA, Tukey post-hoc and Student-t tests. After 48 hours of incubation in artificial saliva, the outcome can be presented as follows regarding the traction test: G IV > G III > G I > G II. On the other hand, after 240 days of incubation the outcome was G VIII = G VII  G VI  G V. The findings allow us to state that the tensile bond strength of fiberglass posts cemented in bovine teeth roots was affected by the variable time because the longer the aging the lower is the resistance, except the glass ionomer cement. / Doutor
230

Efeito da neutralização e limpeza sônica do precipitado do ácido fluorídrico sobre a resistência de união entre uma cerâmica feldspática e um cimento resinoso /

Saavedra, Guilherme de Siqueira Ferreira Anzaloni. January 2006 (has links)
Orientador: Estevão Tomomitsu Kimpara / Banca: Rander Pereira Avelar / Banca: Tarcisio José de Arruda Paes / Resumo: O objetivo deste trabalho foi avaliar três hipóteses: a) o processo de neutralização influencia nos valores de resistência de união entre uma cerâmica feldspática e um cimento resinoso; b) limpeza sônica dos precipitados do ácido fluorídrico aumenta os valores de resistência de união; c) associação entre o do processo de neutralização e a limpeza sônica melhora a resistência de união. Confeccionou-se 32 blocos cerâmicos (VM7 VITA Zahnfabrik), os quais foram duplicados em resina composta (W3D Master). Os resultados deste estudo confirmaram que: a) o processo de neutralização influencia nos valores de resistência de união entre uma cerâmica feldspática e um cimento resinoso; b) a limpeza sônica dos precipitados do ácido fluorídrico aumenta os valores de resistência de união; c) a associação entre o processo de neutralização e a limpeza sônica melhora a resistência de união. / Abstract: This study evaluated three hypotheses: a) the neutralization process influences the bond strength values between a feldspar ceramic and a resin cement; b) ultrasonic cleaning of hydrofluoric acid precipitates increases the bond strength values; c) association between the neutralization process and ultrasonic cleaning improves the bond strength. The present results confirmed that: a) the neutralization process influences the bond strength values between a feldspar ceramic and a resin cement; b) ultrasonic cleaning of hydrofluoric acid precipitates increases the bond strength values; c) association between the neutralization process and ultrasonic cleaning improves the bond strength. / Mestre

Page generated in 0.0859 seconds