• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 558
  • 134
  • 2
  • 2
  • 1
  • Tagged with
  • 695
  • 676
  • 673
  • 83
  • 41
  • 35
  • 31
  • 31
  • 30
  • 27
  • 26
  • 24
  • 20
  • 19
  • 18
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
341

Utvärdering av innemiljön på Vargbroskolan / Evaluation of the indoor environment in Vargbroskolan

Månsson, Sanna, Gustafson, Micaela January 2009 (has links)
<p>Nya Vargbroskolan stod klar januari 2008. Det är en skola unik i sitt slag då fokus under hela projekteringen har legat på energieffektivisering och låg miljöpåverkan. Resultatet blev en superisolerad byggnad med ett hybridventilationssystem med kulvert som värmer luften innan den går in i byggnaden på vintern och kyler på sommaren. För att se hur skolan fungerar i praktiken pågår en utredning där innemiljön och energiåtgången utvärderas.</p><p> </p><p>I den här rapporten behandlas den termiska komforten, luftkvaliteten och ljudmiljön på Vargbroskolan. Ljudmiljön är avgränsad till installationsbuller som orsakas av ventilationssystemet. När det gäller luftkvaliteten är den inriktad på koldioxid och luftburna partiklar. Den termiska komforten beror av fyra faktorer, temperatur, värmeinstrålning, luftrörelser och relativ fuktighet.</p><p> </p><p>Bullermätningar för att mäta den ljudnivå som är orsakad av ventilationssystemet är gjorda enligt SS-EN ISO 16032:2004. Dessa resultat är sedan jämförda med vad de svenska normerna säger. I sex olika klassrum har koldioxidhalt, temperatur och relativ fuktighet mätts med en integrerande mätanordning. För samma klassrum har närvarostatistik förts under två veckor i februari och på så sätt har mätdata och antalet personer kunnat jämföras för att hitta något samband. Partikelmätning har genomförts med hjälp en partikelräknare, Climet CI-500, för att kunna utvärdera kulvertens sedimentationsförmåga när det gäller luftburna partiklar.</p><p>Förutom olika mätningar har också en enkätundersökning gjorts. Det är skolpersonalen som svarat och enkäten är en MM 040 NA, vilket är en standard enkät av Örebromodellen.</p><p> </p><p>Slutsatserna är att bullernivån från ventilationssystemet på Vargbroskolan ligger väldigt nära och ibland lite över normvärdena, vid maximalt flöde. Skolpersonalen tycker inte, enligt enkätundersökningen som gjorts, att detta buller är något störande. Koldioxidhalten ligger lite högt under vissa perioder men verkar inte påverka upplevelsen av inneklimatet negativt. Den termiska komforten är inte särskilt bra på Vargbroskolan, även om den är bättre än på referensskolor enligt enkäten. Sämst är det då det gäller temperaturen. Även om det är kallt uppfattas inte miljön som dragig mer än ibland. Den relativa luftfuktigheten ligger för lågt periodvis, men inte så lågt att det skulle ge fysiska besvär för människorna som vistas i lokalerna. Dock får det ju ses som positivt att en konstant temperatur går att hålla med hjälp av det temperaturstyrda ventilationssystemet.  Detta visar att systemet fungerar bra och som det ska.</p> / <p>In January 2008, the new Vargbroskolan was ready to be used. It is a school unique in its kind because the entire design has been focused on energy efficiency improvement and low environmental impact. The result became a very high isolated building with a hybrid ventilation system. The building has a culvert which heats the air before it gets in to the building in the winter and cools it in the summer. In order to see how the school functions in reality, an investigation where the indoor environment and the energy consumption are evaluated.</p><p> </p><p>In this report, the thermal comfort, the air quality and the sound environment in Vargbroskolan is treated. The sound environment is delimited to the noise caused by the ventilation system. When it comes to the air quality, focus is lying on carbon dioxide and airborne particles. The thermal comfort depends of four factors, temperature, thermal radiation, air movements and relative humidity.</p><p> </p><p>To measure the sound level caused by the ventilation system measurements has been done according to SS-EN ISO 16032:2004. These results are then compared to the Swedish standards. In six different classrooms the carbon dioxide, temperature and relative humidity has been measured with an integrating measuring instrument. For the same classrooms presence statistic has been pursued during two weeks in February. In this way data and the number of persons can be compared in order to find some connections. Particle measurement has been implemented with help of a particle counter, Climet CI-500, in order to evaluate the sedimentation ability of the culvert when it comes to airborne particles. Apart from different measurements an inquiry has also been done. The inquiry is of the kind MM 040 NA which is a standard questionnaire of Örebromodellen and it is the staff on Vargbroskolan who has replied.</p><p> </p><p>The conclusions are that the noise level caused by the ventilation systemet lies near and sometimes a little bit over the standard values, during maximum flow. The staff on Vargbroskolan does not think that this noise is disturbing, according to the inquiry. The concentration of carbon dioxide is a little bit to high during some periods but does not seem to influence the experience of the indoor environment negative either. The thermal comfort is not particularly good in Vargbroskolan, although it is better than the thermal comfort in reference schools according to the inquiry. The temperature is the factor most people complains about, but even though it is cold, the environment does not seem draughty more than sometimes. The relative humidity lies to low periodically, but not so low that it would give physical inconveniences for the people in the classroom. However, the system holds a constant temperature which is positive and it also shows that the system is working correctly.</p>
342

Fuktsäkerhetsbedömning med Wufi / Moisture safety assessment with Wufi

Fredriksson, Eric, Svensson, Mattias January 2009 (has links)
<p>Fuktsäkerhet är ett växande begrepp inom byggbranschen och det läggs ner mer och mer tid</p><p>på att konstruktioner ska bli fuktsäkra. Fukt är komplicerat att beräkna och det kan därför</p><p>underlätta att använda ett beräkningsprogram som hjälpmedel. Wufi är ett tyskt</p><p>fuktberäkningsprogram som nyligen har utkommit i en svensk version. Detta program har</p><p>WSP investerat i för att lättare kunna bedöma fuktsäkerheten i konstruktioner. WSP var</p><p>intresserade av en studie av Wufi för att underlätta introduktionen av programmet i företaget.</p><p>Målet med rapporten är att klargöra hur grundläggande parametrar ska beaktas i programmet</p><p>och hur tillförlitligt programmet är.</p><p> </p><p>För att möjliggöra en bedömning av programmet inleddes arbetet med självstudie av</p><p>programmet, som avslutades med en kort utbildning i programmet. Efter detta utfördes ett</p><p>antal parametertester i programmet för att få svar på hur dessa skall hanteras. För</p><p>bedömningen av tillförlitligheten i programmet utfördes därefter en större studie på</p><p>putsväggar med olika putssystem. Beräkningsresultaten från programmet jämfördes med de</p><p>problem som har uppstått på dessa konstruktioner.</p><p> </p><p>Parametertesterna visar att materialegenskaperna har stor påverkan på resultatet och det är</p><p>således viktigt att använda material på rätt sätt och med rätt värden. Val av tidssteg för</p><p>beräkningarna ger ingen större skillnad i resultat. Beräkningar i programmet kan därav utföras</p><p>med en timmes tidssteg och på så sätt minimera beräkningstiden.</p><p> </p><p>Används Wufi och dess parametrar på rätt sätt ger programmet tillförlitliga resultat.</p><p>Resultaten från de beräknade putsväggarna i Wufi följer de problem och diskussioner som har</p><p>uppkommit kring puts på träregelväggar. Programmet är dock helt beroende av vad man</p><p>väljer för indata och materialegenskaper. Kontrollerar man inte dessa noga finns det risk för</p><p>att resultatet blir felaktigt och då försvinner även tillförlitligheten till programmet.</p><p> </p><p>För att programmet skall få en slagkraft i en organisation som WSP, bör en genomarbetning</p><p>av materialdatabasen att utföras. Detta ökar användarvänligheten betydligt och projektörer</p><p>som normalt inte jobbar med byggnadsfysik skulle då kunna bedöma fuktsäkerheten i ett</p><p>aktuellt projekt. För att bibehålla kontrollen över fuktsäkerheten bör det dock finnas tydliga</p><p>föreskrifter för hur programmet skall användas.</p> / <p>Moisture safety is a rising concept in the construction industry and building designers spent</p><p>more and more time on the moisture safety designs. Moisture is complicated to calculate and</p><p>the use of a calculation program could make the process easier. Wufi is a German moisture</p><p>calculation program that recently has been presented in a Swedish version. WSP has invested</p><p>in the program to better assess the moisture safety in structures. WSP was interested in a study</p><p>of Wufi to facilitate the introduction of the program in the company. The objective of this</p><p>report is to clarify how the basic parameters are to be considered in the program and how</p><p>reliable the program is.</p><p> </p><p>In order to make an evaluation possible the process started with self-study of the program, and</p><p>ended with a short education in the program. After this a number of parametric tests were</p><p>conducted in the program to answer how these should be dealt with. For the assessment of the</p><p>reliability of the program a major study on plaster walls with different plaster system was</p><p>made. The results were compared with the problems that have occurred on these structures.</p><p> </p><p>The parameter tests shows that material properties have a major impact on the outcome and it</p><p>is therefore important to use materials in the right way and with the right values. The test of</p><p>time steps indicates small difference in outcome. Calculations in the program can therefore be</p><p>carried out with an hour time step and thus minimizing the calculation time.</p><p> </p><p>Used correctly, the Wufi program and its parameters provides reliable results. The result from</p><p>the plaster walls in Wufi follows the implications and discussions that have aroused about the</p><p>plaster on wood frame. However, the application is entirely dependent on what you choose for</p><p>input and material properties. If these are not carefully controlled, there is a risk that the</p><p>results are wrong and the reliability of the program is then gone.</p><p> </p><p>For the program to reach a useful position in an organization such as WSP, an update of the</p><p>material database ought to be done. This increases the usability significantly and building</p><p>designers who do not normally work with building physics could then be able to determine</p><p>the moisture safety in a construction. In order to maintain control over moisture safety,</p><p>however, there should be clear policies for how the program should be used.</p>
343

Energibesparing åt Klövern AB :  Förslag på åtgärder för minskad driftkostnad för Klövern AB’s fastigheter / Energy saving för Klövern AB : Proposed measures to reduce operating costs

Eriksson, Per, Trygg-Svensson, Sebastian, Österbring, Magnus January 2010 (has links)
<p>Fastighetsbolaget Klövern AB förvaltar 45 fastigheter i Karlstad kommun. Med stigande energipriser ökar behovet för Klövern att energieffektivisera sina fastigheter för att minska kostnaderna. Rapportens syfte är att undersöka tre av Klövern utvalda fastigheter med hög energiförbrukning. Målet är att presentera energibesparande åtgärder för Klövern att använda som beslutsunderlag för framtida investeringar. För åtgärdsförslagen görs LCC-analyser för att undersöka om de är lönsamma. Därefter görs känslighetsanalys för de mest lönsamma alternativen för att tydliggöra osäkerheten i beräkningsunderlaget. De åtgärder som rekommenderas har ett positivt nuvärde efter livslängd, rangordning av dessa alternativ görs sedan efter avkastning. De tre fastigheterna är Gripen 11, Blåsten 4, Styrmannen 5.</p><p> </p><p>För Gripen 11 undersöktes möjligheterna att installera solfångare, åtgärda ventilationssystem och att tilläggsisolera vissa delar av fastigheten. Resultatet visar att de bästa energibesparingsåtgärderna är att öka temperaturverkningsgraden för värmeväxlare i system 1 vilket ger en besparing på ca 135000 kWh/år samt att optimera drifttiden för system 2 vilket ger en besparing på ca 17000 kWh/år. Installation av 110 kvm solfångare ger en årlig energibesparing på ca 48000 kWh/år.</p><p> </p><p>Blåsten 4 består av en huvudbyggnad med fyra ventilationssystem samt en lagerlokal med luftvärmepumpar. För fastigheten undersöktes effekten av att ersätta ventilationssystem 2, 3 och 4 med ett nytt gemensamt ventilationssystem med värmeväxlare. Undersökningar har gjorts för hur lönsamheten ser ut för att byta uppvärmningssystem från, i dagsläget, direktverkande el. Nya system som undersöktes är bergvärme, fjärrvärme, en kombination av dessa samt luft/vatten-värmepump. Vid byte av uppvärmningssystem inkluderas installation av radiatorsystem. Analys av lönsamhet för tilläggsisolering, solceller och solfångare har genomförts. Resultatet visar att åtgärda ventilationssystemen enligt ovan ger en energibesparing på ca 235000 kWh/år. Att byta uppvärmningssystem till fjärrvärme ökar energikonsumtionen med ca 70000 kWh/år men ger en besparing på ca 130000 kr/år då fjärrvärme är ett billigare alternativ än direktverkande el (kr/kWh). Installation av solfångare med bidrag från Boverket är lönsamt och ger en energibesparing på ca 8800 kWh/år.</p><p> </p><p>Styrmannen 5 består av två byggnader med kontorsverksamhet. Fastigheterna är fristående men binds ihop av ett garage under marken som värms upp till 12 grader. Tre ventilationssystem med värmeväxling finns i byggnaderna samt frånluftssystem. Liknande förutsättningar gäller för båda fastigheterna, stora delar av fasaderna består av fönster och FTX-systemen har relativt hög verkningsgrad. Mellan husen finns en park som i dagsläget är uppvärmt med markvärme under vinterhalvåret för att hålla den snöfri. De åtgärdsförslag som undersökts för att minska energianvändningen är dels att installera ventilationssystem med högre verkningsgrad än vad som idag finns, bygga om ett ventilationssystem för att värma garaget med frånluft, helt stänga av uppvärmningen av garaget samt att snöröja parken manuellt istället för med markvärme. Resultatet visar att installation av nya ventilationssystem inte klarar lönsamhetskraven, åtgärder medför en energibesparing för hus A på ca 24000 kWh/år och för hus B ca 15500kWh/år. Däremot klarar ombyggnationen av ventilationssystemet för att värma garaget lönsamhetskravet och sparar ca 140000 kWh/år. Då åtgärderna att snöröja istället för markvärme samt att helt stänga av uppvärmningen av garaget inte har någon investeringskostnad kan avkastning inte beräknas, dessa åtgärder skulle dock spara ca 180000 kWh/år respektive ca 95000 kWh/år. </p> / <p>The real estate company Klövern LTD manages 45 properties in Karlstad. With rising energy prices the necessity to be more energy efficient in their properties to reduce costs, increases. The reports purpose is to examine three of Klöverns worst properties concerning high energy consumption. The goal is to introduce energy saving measures to Klövern which will be used as a basis for future investments. LCC-analyses are made to examine whether or not different modifications and installations are profitable. Sensitivity analysis is done for the most viable options to clarify the uncertainty in the calculations e.g. investment cost, inflation. The recommended actions have a positive LCC-value under their life-span, the ranking of these alternatives are then made after how much they yield under their life-span. The three properties that are examined are Gripen 11, Blåsten 4, Styrmannen 5. For Gripen 11 surveys where made for the possibility of installing solar panels, installation of  new heat exchangers to some of the ventilation system and to put in additional insulation in certain parts of the property. Results show that the best energy saving measures is to increase the temperature efficiency of heat exchangers in system one which gives a saving of approximately 135 000 kWh/year, and to optimize the operating time of system two resulting in a saving of approximately 17 000 kWh/year. Installation of 110 square meters of solar collectors provide an annual energy saving of approximately 48 000 kWh/year. Blåsten 4 consists of a main building with four ventilation systems and a warehouse with heat pumps. For this property, studies where made as to the effect of replacing three ventilation systems (2, 3 and 4) with one new ventilation system with a heat exchanger. Studies have been undertaken for the profitability of changing the heating system from, the current situation, heating by electricity. New heating systems that were investigated where geothermal heating, district heating, a combination thereof, and air/water heat pump. The replacing of the heating system includes an installation of radiator systems. Analyses of the profitability of solar cells and solar panels have also been made. The results show that to modify the ventilation systems, as described above, provides an energy saving of approximately 235 000 kWh/year. Replacing the heating system with district heating will increase the energy consumption by about 70 000 kWh/year, but will give a saving of approximately 130 000 SEK/year because district heating is a cheaper alternative than heating with electricity (SEK/kWh). Installation of solar panels, with grants from Boverket, is profitable and provides an energy saving of about 8800 kWh/year. Styrmannen 5 consists of two office buildings. The buildings are independent but bound together by an underground garage which is heated to 12 degrees. Three ventilation systems with heat exchange and one exhaust system without exists in the buildings. Similar conditions apply to both buildings, large parts of the facades are made up of windows and the heat exchangers in the ventilation systems have a rather high efficiency. Between the houses there is a park which is heated by ground heat in the winter to keep it free from snow. Studies were made to examine the effects of installing a new heat exchange system with high efficiency to reduce energy use, rebuild one of the ventilation systems in order to use the exhaust air to heat the garage, al together turn off the heating of the garage and to remove the snow manually instead of using ground heat. The results show that installing a new heat exchange systems will not be profitable. Rebuilding one of the ventilation systems to heat the garage is profitable and saves approximately 140 000 kWh/year. The measures to manually remove snow in the winter instead of ground heat, and turning of the heating of the garage would save about 180 000 kWh/year respectively approximately 95 000 kWh/year.</p>
344

Framtidens energieffektiva flerbostadshus / Future energy effective multi-dwelling buildings

Bäckström, Carolin, Gauffin, Emma January 2010 (has links)
<p>The housing sector of today represents for almost 40% of the energy consumption, an energy consumption of which the major part consists of non-renewable energy sources. This is not sustainable and utilization of new energy-efficient technologies in buildings can be a step in the right direction, towards a sustainable energy society.</p><p>This report has been made on behalf of and in cooperation with Älvstranden Utveckling AB in Gothenburg to examine how future energy-efficient technologies can affect the energy demand in energy-efficient multi-dwelling buildings.</p><p>The report is based on Älvstrandens passive house, Hamnhuset, a house whose energy consumption is far below the BBR's requirements. The report looks at the opportunities for improvement within windows, insulation, solar energy technologies, as well as white goods. Computer simulations are then made to apply the selected technologies into a reference building. Technologies are selected from an energy efficient perspective and no account has been taken of other aspects such as the economy. They must also be available on the market within a ten-year period. Information has been gathered through interviews and contacts with experts in their respective fields, as well as representatives of the various technologies.</p><p>By using high-efficient insulation and smart windows, heat transmission losses and thus the heat demand can be reduced. Increased solar irradiation through the windows during the winter months also contributes to a reduction in need of purchased energy during the coldest part of the year, when the supply of renewable energy is minimal. A large part of the needed electricity may be covered by electricity from solar cells mounted on the roof, balcony fronts and facades. A reduction of purchased electricity has a major impact on the building's stress on the environment and carbon dioxide emissions from a life cycle perspective. That is also why electricity heated white goods are exchanged into appliances on district heating.</p><p>By installing a larger amount of and more efficient solar collectors which also has a smoother heat production over the year, the need for heating domestic hot water is reduced.</p><p>The calculations are made in two stages, the first sets out the various technologies effectiveness and potential individually; several simulations have been made for one and the same technology to provide different variations depending on the situation it is used. For example, several combinations of windows are tested in different orientations. In step two, the techniques with the greatest energy saving potential are selected in order to jointly result in a final house. To see how a future streamlining of household technology and lighting affects the energy balance of a building, a simulation is also made where household electricity is reduced by 40%.</p><p>The result of selected energy efficiency measures shows a reduction of the specific energy demand by 70 % compared to the BBR's requirements and 50 % compared to the reference house. In addition the environmental impact of the building reduces from a CO2 perspective with 85 % compared to the reference house. However, there is an uncertainty of the results as they are based on speculations in the technologies future capacity. Results should therefore be seen as an inspiration for how high the objectives can be set in the construction of energy-efficient buildings.</p><p>Still, in the light of this report, there are great opportunities to within a ten-year period build multi-dwelling buildings that are way more energy efficient than today.</p>
345

Train-Induced Vibrations on Embankments and in Buildings : Prediction and Validation of Some Models

With, Christoffer January 2008 (has links)
QC 20100921
346

Utvärdering av innemiljön på Vargbroskolan / Evaluation of the indoor environment in Vargbroskolan

Månsson, Sanna, Gustafson, Micaela January 2009 (has links)
Nya Vargbroskolan stod klar januari 2008. Det är en skola unik i sitt slag då fokus under hela projekteringen har legat på energieffektivisering och låg miljöpåverkan. Resultatet blev en superisolerad byggnad med ett hybridventilationssystem med kulvert som värmer luften innan den går in i byggnaden på vintern och kyler på sommaren. För att se hur skolan fungerar i praktiken pågår en utredning där innemiljön och energiåtgången utvärderas.   I den här rapporten behandlas den termiska komforten, luftkvaliteten och ljudmiljön på Vargbroskolan. Ljudmiljön är avgränsad till installationsbuller som orsakas av ventilationssystemet. När det gäller luftkvaliteten är den inriktad på koldioxid och luftburna partiklar. Den termiska komforten beror av fyra faktorer, temperatur, värmeinstrålning, luftrörelser och relativ fuktighet.   Bullermätningar för att mäta den ljudnivå som är orsakad av ventilationssystemet är gjorda enligt SS-EN ISO 16032:2004. Dessa resultat är sedan jämförda med vad de svenska normerna säger. I sex olika klassrum har koldioxidhalt, temperatur och relativ fuktighet mätts med en integrerande mätanordning. För samma klassrum har närvarostatistik förts under två veckor i februari och på så sätt har mätdata och antalet personer kunnat jämföras för att hitta något samband. Partikelmätning har genomförts med hjälp en partikelräknare, Climet CI-500, för att kunna utvärdera kulvertens sedimentationsförmåga när det gäller luftburna partiklar. Förutom olika mätningar har också en enkätundersökning gjorts. Det är skolpersonalen som svarat och enkäten är en MM 040 NA, vilket är en standard enkät av Örebromodellen.   Slutsatserna är att bullernivån från ventilationssystemet på Vargbroskolan ligger väldigt nära och ibland lite över normvärdena, vid maximalt flöde. Skolpersonalen tycker inte, enligt enkätundersökningen som gjorts, att detta buller är något störande. Koldioxidhalten ligger lite högt under vissa perioder men verkar inte påverka upplevelsen av inneklimatet negativt. Den termiska komforten är inte särskilt bra på Vargbroskolan, även om den är bättre än på referensskolor enligt enkäten. Sämst är det då det gäller temperaturen. Även om det är kallt uppfattas inte miljön som dragig mer än ibland. Den relativa luftfuktigheten ligger för lågt periodvis, men inte så lågt att det skulle ge fysiska besvär för människorna som vistas i lokalerna. Dock får det ju ses som positivt att en konstant temperatur går att hålla med hjälp av det temperaturstyrda ventilationssystemet.  Detta visar att systemet fungerar bra och som det ska. / In January 2008, the new Vargbroskolan was ready to be used. It is a school unique in its kind because the entire design has been focused on energy efficiency improvement and low environmental impact. The result became a very high isolated building with a hybrid ventilation system. The building has a culvert which heats the air before it gets in to the building in the winter and cools it in the summer. In order to see how the school functions in reality, an investigation where the indoor environment and the energy consumption are evaluated.   In this report, the thermal comfort, the air quality and the sound environment in Vargbroskolan is treated. The sound environment is delimited to the noise caused by the ventilation system. When it comes to the air quality, focus is lying on carbon dioxide and airborne particles. The thermal comfort depends of four factors, temperature, thermal radiation, air movements and relative humidity.   To measure the sound level caused by the ventilation system measurements has been done according to SS-EN ISO 16032:2004. These results are then compared to the Swedish standards. In six different classrooms the carbon dioxide, temperature and relative humidity has been measured with an integrating measuring instrument. For the same classrooms presence statistic has been pursued during two weeks in February. In this way data and the number of persons can be compared in order to find some connections. Particle measurement has been implemented with help of a particle counter, Climet CI-500, in order to evaluate the sedimentation ability of the culvert when it comes to airborne particles. Apart from different measurements an inquiry has also been done. The inquiry is of the kind MM 040 NA which is a standard questionnaire of Örebromodellen and it is the staff on Vargbroskolan who has replied.   The conclusions are that the noise level caused by the ventilation systemet lies near and sometimes a little bit over the standard values, during maximum flow. The staff on Vargbroskolan does not think that this noise is disturbing, according to the inquiry. The concentration of carbon dioxide is a little bit to high during some periods but does not seem to influence the experience of the indoor environment negative either. The thermal comfort is not particularly good in Vargbroskolan, although it is better than the thermal comfort in reference schools according to the inquiry. The temperature is the factor most people complains about, but even though it is cold, the environment does not seem draughty more than sometimes. The relative humidity lies to low periodically, but not so low that it would give physical inconveniences for the people in the classroom. However, the system holds a constant temperature which is positive and it also shows that the system is working correctly.
347

Övergång till helkrossballast : En studie för Strängbetongfabrikerna i Veddige och Herrljunga

Stålnacke, Ricard January 2009 (has links)
This exam report has been developed in association with Strangbetong AB, Sweden. The natural gravel that is being used as fine aggregate for concrete production today is an ending natural recourse and the Swedish government has decided to strongly reduce the extraction from the year of 2020. The only reasonable replacement is aggregates from crushed rocks but this material has other properties than natural aggregates. The concrete manufacturers now have to learn how to use these new fine aggregates in a cost effective way in order to ensure the quality of their concrete production. In this project, crushed aggregates and combination of crushed and natural aggregates have been tested with existing formulas for fresh concrete. The two parameters yield stress and plastic viscosity have been measured which gives a good description of the workability of the fresh concrete. Different methods to make measurements on the dry fine aggregates, has also been tested, to find out if there is any correlations between these parameters and the parameters from the measurement on the fresh concrete.
348

Ekologiskt anpassat typhus för Eksjöhus / Eco-adapted model house for Eksjöhus

Johansson, Sara, Karlsson, Elin January 2009 (has links)
Hela 85 % av byggnadsmaterialen i ett nybyggt hus består av hälso- eller miljöfarliga material. Detta måste förändras! Ekologiskt byggande handlar om att undvika dessa material i så stor utsträckning som möjligt och samtidigt reducera uppvärmningen och tappvattenförbrukning med hjälp av energieffektiva installationer. Att det går att minska de miljöfarliga materialen i ett hus är självklart, men är det möjligt att bygga ett hus med nästan inga miljö- och hälsofarliga material? Vilka tekniska lösningar är att föredra vid ekologiskt byggande? Hur utformas ett ekologiskt hus? Syftet med detta examensarbete är att hjälpa Eksjöhus att ta fram ett ekologiskt anpassat enfamiljshus och därmed bidra till ett sundare boende och en bättre miljö. Förundersökningar i form av utredningar av material, installationsmöjligheter och arkitektonisk utformning av ett ekologiskt hus ligger till grund för framtagning av huset och är en mycket viktig del i rapporten. Huset ska anpassas till tillverkningen i Eksjöhus fabrik och till andra standarder som Eksjöhus tillämpar. Under arbetets gång har tre besök gjorts på Eksjöhus. Olika lösningar har diskuterats med vår fadder David Norrman och en visning i deras produktionshall har ägt rum. Undersökningarna har resulterat i ett enfamiljshus med fem rum och kök med en bostadsarea på 146,8 m2. Huset är i ett plan och har en modern stil. Ekologiska material, som inte belastar miljön och som är förnyelsebara, har använts i så stor utsträckning som möjligt. Huset har en stomme av trä och är isolerat med hampafibrer. Som isolering i grunden används cellglas och sedum har valts som taktäckningsmaterial. Även andra komplement såsom färger, skivmaterial, golvmaterial och inredningar är valda med hänsyn tagen till miljön. Konstruktionen är diffusionsöppen, vilket gör att huset andas och att fuktigheten i inomhusluften jämnas ut. På så vis blir inomhusklimatet bättre. Huset är försett med solfångare, pelletspanna och en vattenmantlad kakelugn som försörjer huset med tappvarmvatten och bidrar till dess uppvärmning. Dessa tre värmekällor är kopplade till en ackumulatortank och får värmeenergin från förnyelsebara eller oändliga resurser, nämligen solenergi, pellets och ved. En modell av huset har gjorts i ArchiCAD. Därifrån har sedan ritningar i form av plan, fasader och sektioner tagits fram. Alla detaljritningar har ritats i AutoCAD. Det ställs många krav på ett hus. Det ska bland annat klara vissa fuktkrav och energikrav. Beräkning av husets specifika energianvändning har gjort i programmet BV2. Värmegenomgångs- och kondensriskberäkningar har utförts i Excel. Vid framtagning av ett ekologiskt hus är det många aspekter som måste vägas in i dess utformning. Det finns många material att välja bland och materialens hela livscykel ska vägas in vid materialvalen. Installationer måste också utredas så att ett flexibelt och energisnålt värmesystem erhålls. / Today 85 % of all buildingmaterial in a new-built house is based on environment- or health-hazardous material. This must change! Ecological construction is all about avoiding these materials in as many ways as possible and in the same time reduce heating and the water usage with the help of energy-efficient installations. It is possible to reduce the material that are harmful to the environment in a house, but is it possible to construct a house with almost no environment- or health hazardous material? What technical solutions are preferable when constructing an ecological house? How is an ecological house designed? The purpose with this paper is to assist Eksjöhus to develop an eco-adapted singlefamilyhouse and thereby aiding to a better living and environment. Preliminary investigation such as material, installation-possibilities and research of architectural design of an eco-adapted house are important parts of this paper. The house will be adapted to Eksjöhus fabrication and other standards that Eksjöhus uses. During the making of this paper three visits to Eksjöhus has been made. During these visits different solutions has been discussed with our contact-person David Norrman and a showing of Eksjöhus productionhall has been done. The researches have resulted in a single-familyhouse with five rooms and kitchen with a livingarea of 146,8 m2. The house is based on one floor and has a modern style and feeling. Ecological materials, which doesn't damage the environment and are renewable has been used in the larges scale as possible. The house has a frame of wood and is isolated with hempfibre. Foamglass has been used to isolate the foundation, and sedum has been chosen for covering the roof. Other complementary material such as paints, boardmaterial, floormaterial and decoration has been chosen with care and regard to the environment. The construction is diffusion-open, which allows the house to breathe. The air humidity inside level off and the indoor-climate gets better. The house is equipped with solar collectors, pellets stove and a water heating tile stove that supplies the house with hot water and in the same time helps with the heating. These three heat sources are wired to an accumulation tank and get its heat energy from renewable or infinite resources – solarenergy, pellets and wood. A model of the house has been made in ArchiCAD. From this model the layouts in shape of plan, facings and sections have been developed. All detail layouts has been drawn in AutoCAD. There are many requirements when constructing a house. The house should, among other things, fulfill requirements regarding moisture and energy. The calculation of the house specific energy usage has been made in BV2. The heat transfer and the condensation risk analysis has been made in Excel. When developing an ecological house, there are many aspects to consider in its design. There is a variety of materials to choose from and the material´s whole lifecycle must take an important role when deciding the material. Even installations must be examined to get a flexible and energy-efficient heating system.
349

Förslag till illustrationsplan för Gartnerskolen – Søhus, Odense, Danmark / Master plan proposal for Gartnerskolen – Søhus, Odense, Denmark

Elamzon, Linnéa January 2010 (has links)
Is it possible that by planning in a more sustainable way when building a new area, we can improve our environment? Most environmental problems are created in cities and therefore they should hold the solution. Through a more ecological urban planning a better foundation for sustainable housing could be created. This report follows the process in coming up with a proposal for a master plan for an area in Odense, Denmark. By going through principles for sustainable urban planning made by different organizations and persons and from these extract main principles, a background is founded to continue the proposal from. Denmark works a lot on expanding their green areas, maintain the existing ones and recreate what’s being destroyed as cities expand. The municipality of Odense works along these outlines and has a special interest in preserving old neighbourhoods and buildings that have an important local history. The area Gartnerskolen – Søhus is located in the outskirts of Odense and is currently used for cultivating fruits and as a university for gardeners. The surroundings are well known for the history of an area with many greenhouses and this heritage is important to preserve. During the planning process it’s been important to create a pleasant and well functioning area – not only a sustainable experiment. Gartnerskolen – Søhus should be an attractive place to live which is also sustainable. There are several buildings on site and all of them have been preserved but in some cases the purpose of them has been altered. Likewise the tall hedges that originally protect the fruit trees from hard winds have been maintained to add more character to the area. In order to facilitate the understanding those parts of this report that concern the master plan it is recommended to have the appendix with the proposal at hand.
350

Jämförelse mellan BIM­­-verktygen Revit Structure och Tekla Structures

Isaksson, Jonas, Werborg, Mathias January 2011 (has links)
No description available.

Page generated in 0.3789 seconds