• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 141
  • 115
  • 32
  • 28
  • 14
  • 9
  • 8
  • 6
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • Tagged with
  • 402
  • 402
  • 159
  • 74
  • 60
  • 48
  • 37
  • 35
  • 34
  • 30
  • 29
  • 29
  • 28
  • 28
  • 27
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
201

Análise da distribuição de tensão em protocolo mandibular confeccionado pelo sistema convencional e CAD/CAM, variando tipo, número e inclinação dos implantes / Stress distribution analysis of mandibular protocol confectioned by the conventional system and cad/cam, ranging type, number and inclination of the implants

Sbardelotto, Cristian 19 January 2016 (has links)
As próteses totais fixas implantossuportadas tem ganhado cada dia mais seu espaço no tratamento reabilitador de pacientes edêntulos, pois se trata de uma forma de tratamento que atende todos os quesitos funcionais e estéticos. Ainda não existe na literatura um consenso de qual a configuração que melhor distribui as tensões aos implantes e tecidos adjacentes. O objetivo deste estudo foi comparar as tensões geradas na interface osso-implante de próteses totais mandibulares implantossuportadas através do método de correlação de imagens digitais (CID). Foram analisadas duas configurações diferentes quanto a quantidade e posicionamento de implantes (4 ou 5 implantes), diferentes conexões [hexágono externo (HE) e cone morse (CM)] e barras para prótese fixa implantossuportada obtidas por fundição convencional e usinadas pelo sistema CAD/CAM. Foram confeccionados modelos em poliuretano, utilizando implantes de 3,75x11mm, divididos em 8 grupos: G1 (5 implantes/HE/CAD-CAM), G2 (5 Implantes/CM/CAD CAM), G3 (5 Implantes/HE/Convencional), G4 (5 Implantes/CM/Convencional), G5 (4 Implantes/HE/CAD CAM), G6 (4 Implantes/CM/CAD CAM), G7 (4 Implantes/HE/Convencional) e G8 (4 Implantes/CM/Convencional). A análise por CID foi feita quantitativamente e qualitativamente, com aplicação de carga de 250N na fossa central do primeiro molar inferior, onde foram estabelecidas diferentes regiões de interesse para a análise, sendo denominadas de C1 (cervical 1) e A1 (apical 1) para região distal ao último implante, C2 (cervical 2) e A2 (apical) para região mesial ao último implante. Foram encontradas diferenças estatisticamente significantes para o número de implantes em todas as regiões analisadas [C1 (p=0,002), A1 (p=0,01), C2 (p=0,001), A2 (p=0,004)], para as conexões foram encontradas diferenças na região C2 (p<0,05) e para as barras na região A2 (p=0,003). De acordo com os resultados pode-se concluir que as prótese com 4 implantes apresentaram maior quantidade de tensões por tração nas regiões apicais, não houve diferença significativa na concentração de tensões para as conexões HE e CM, exceto para a região C2, onde houve maior concentração de tensão para conexão CM e em comparação ao método de obtenção das barras, as barras convencionais apresentaram maior concentração de tensões de tração nas próteses com 5 implantes. / The implant-supported fixed dental prostheses have been used to rehabilitate edentulous patients as it fulfills not only functional aspects but also esthetic questions. Literature shows that there is no consensus about the best configuration to distribute stress to the implants and surrounding tissues. The objective of this study was to compare the stress generated at the boneimplant interface of implant-supported mandibular dentures by a digital image correlation method (DIC). Two different configurations were analyzed for the implants quantity and position (4 or 5 implants), different connections [external hexagon (EH) and Cone Morse (CM)] and bars for implant-supported fixed prosthesis obtained by conventional casting and machined by CAD/CAM system. Models were prepared from polyurethane and implants (3.75x11mm) were divided in 8 groups: G1 (5 implants/EH/CAD-CAM), G2 (5 Implants/CM/CAD-CAM), G3 (5 Implants/EH/Conventional) , G4 (5 Implants/CM/Conventional), G5 (4 Implants/EH/CAD-CAM), G6 (4 Implants/CM/CAD-CAM) G7 (4 Implants/EH/Conventional) and G8 (4 Implants/CM/Conventional). DIC analysis were quantitative and qualitatively made with a 250N load at first molar central fossa, which were established in different regions of interest for analysis as C1 (cervical 1) and A1 (apical 1) to distal to the last implant, C2 (cervical 2) and A2 (apical) for mesial region to the last implant. Statistically significant differences were found for number of implants in all regions examined [C1 (p=0.002), A1 (p=0.01), C2 (p=0.001) and A2 (p=0.004)], for connections differences were found in the C2 region (p <0.05) and for the bar region at A2 (p=0.003). According to the results it can be concluded that the prosthesis with four implants showed a higher stress at the apical regions, there was no significant difference in the concentration of stress for EH and CM connections, except for the C2 region, where there was a higher concentration of stress for CM connection, and comparing bars obtained methods, conventional bars showed a higher concentration of stresses in prosthesis with 5 implants.
202

Análise da distribuição de tensão em protocolo mandibular confeccionado pelo sistema convencional e CAD/CAM, variando tipo, número e inclinação dos implantes / Stress distribution analysis of mandibular protocol confectioned by the conventional system and cad/cam, ranging type, number and inclination of the implants

Cristian Sbardelotto 19 January 2016 (has links)
As próteses totais fixas implantossuportadas tem ganhado cada dia mais seu espaço no tratamento reabilitador de pacientes edêntulos, pois se trata de uma forma de tratamento que atende todos os quesitos funcionais e estéticos. Ainda não existe na literatura um consenso de qual a configuração que melhor distribui as tensões aos implantes e tecidos adjacentes. O objetivo deste estudo foi comparar as tensões geradas na interface osso-implante de próteses totais mandibulares implantossuportadas através do método de correlação de imagens digitais (CID). Foram analisadas duas configurações diferentes quanto a quantidade e posicionamento de implantes (4 ou 5 implantes), diferentes conexões [hexágono externo (HE) e cone morse (CM)] e barras para prótese fixa implantossuportada obtidas por fundição convencional e usinadas pelo sistema CAD/CAM. Foram confeccionados modelos em poliuretano, utilizando implantes de 3,75x11mm, divididos em 8 grupos: G1 (5 implantes/HE/CAD-CAM), G2 (5 Implantes/CM/CAD CAM), G3 (5 Implantes/HE/Convencional), G4 (5 Implantes/CM/Convencional), G5 (4 Implantes/HE/CAD CAM), G6 (4 Implantes/CM/CAD CAM), G7 (4 Implantes/HE/Convencional) e G8 (4 Implantes/CM/Convencional). A análise por CID foi feita quantitativamente e qualitativamente, com aplicação de carga de 250N na fossa central do primeiro molar inferior, onde foram estabelecidas diferentes regiões de interesse para a análise, sendo denominadas de C1 (cervical 1) e A1 (apical 1) para região distal ao último implante, C2 (cervical 2) e A2 (apical) para região mesial ao último implante. Foram encontradas diferenças estatisticamente significantes para o número de implantes em todas as regiões analisadas [C1 (p=0,002), A1 (p=0,01), C2 (p=0,001), A2 (p=0,004)], para as conexões foram encontradas diferenças na região C2 (p<0,05) e para as barras na região A2 (p=0,003). De acordo com os resultados pode-se concluir que as prótese com 4 implantes apresentaram maior quantidade de tensões por tração nas regiões apicais, não houve diferença significativa na concentração de tensões para as conexões HE e CM, exceto para a região C2, onde houve maior concentração de tensão para conexão CM e em comparação ao método de obtenção das barras, as barras convencionais apresentaram maior concentração de tensões de tração nas próteses com 5 implantes. / The implant-supported fixed dental prostheses have been used to rehabilitate edentulous patients as it fulfills not only functional aspects but also esthetic questions. Literature shows that there is no consensus about the best configuration to distribute stress to the implants and surrounding tissues. The objective of this study was to compare the stress generated at the boneimplant interface of implant-supported mandibular dentures by a digital image correlation method (DIC). Two different configurations were analyzed for the implants quantity and position (4 or 5 implants), different connections [external hexagon (EH) and Cone Morse (CM)] and bars for implant-supported fixed prosthesis obtained by conventional casting and machined by CAD/CAM system. Models were prepared from polyurethane and implants (3.75x11mm) were divided in 8 groups: G1 (5 implants/EH/CAD-CAM), G2 (5 Implants/CM/CAD-CAM), G3 (5 Implants/EH/Conventional) , G4 (5 Implants/CM/Conventional), G5 (4 Implants/EH/CAD-CAM), G6 (4 Implants/CM/CAD-CAM) G7 (4 Implants/EH/Conventional) and G8 (4 Implants/CM/Conventional). DIC analysis were quantitative and qualitatively made with a 250N load at first molar central fossa, which were established in different regions of interest for analysis as C1 (cervical 1) and A1 (apical 1) to distal to the last implant, C2 (cervical 2) and A2 (apical) for mesial region to the last implant. Statistically significant differences were found for number of implants in all regions examined [C1 (p=0.002), A1 (p=0.01), C2 (p=0.001) and A2 (p=0.004)], for connections differences were found in the C2 region (p <0.05) and for the bar region at A2 (p=0.003). According to the results it can be concluded that the prosthesis with four implants showed a higher stress at the apical regions, there was no significant difference in the concentration of stress for EH and CM connections, except for the C2 region, where there was a higher concentration of stress for CM connection, and comparing bars obtained methods, conventional bars showed a higher concentration of stresses in prosthesis with 5 implants.
203

Avaliação de dois diferentes planejamentos de próteses totais fixas implantossuportadas, comparando as técnicas de fabricação das infraestruturas: tecnologia CAD-CAM, fundição convencional e barra articulada / Evaluation of two different designs of full-arch implant-supported fixed dentures, comparing the infrastructure manufacturing techniques: CAD-CAM technology, conventional casting and Articulated Bar

Silva, Rafael Cândido Pedroso e 27 January 2016 (has links)
O objetivo deste estudo foi avaliar dois diferentes planejamentos de próteses totais fixas implantossuportadas, comparando as técnicas de fabricação das infraestruturas: tecnologia CAD-CAM, fundição convencional e Barra Articulada. Após ciclagem termomecânica, foram analisadas a perda de torque dos parafusos protéticos e adaptação marginal vertical e horizontal. Ao final, as próteses foram submetidas a ensaios de fadiga acelerada progressiva e resistência à fratura. Foram confeccionadas 48 próteses totais fixas implantossuportadas, as quais foram divididas inicialmente em dois grupos, G1 protocolo convencional; G2 - &ldquo;All-on-4&rdquo;. De acordo com a técnica de fabricação das infraestruturas, estes grupos foram divididos em três subgrupos, A - tecnologia CAD-CAM; B - fundição convencional; C - Barra Articulada, proporcionando seis amostragens diferentes: G1A, G1B, G1C, G2A, G2B e G2C (n=8). Todas as próteses foram avaliadas em relação à adaptação marginal vertical e horizontal, utilizando MicroCT, antes e após a ciclagem termomecânica (2.000.000 de ciclos). A perda de torque dos parafusos protéticos foi analisada antes (T0), após 1.000.000 (T1) e 2.000.000 de ciclos (T2). Após este ensaio, as próteses foram submetidas ao teste de fadiga acelerada progressiva (n=8) e em sequência, ensaio de resistência à fratura (n=6). A perda de torque teve diferença significante para todos os tempos comparados (p<0,01), exceto em G2B, onde a comparação entre T1 - T2 não mostrou diferença significante (p=0,72). A comparação entre G1 e G2 não foi significante. A comparação entre os subgrupos A, B e C teve diferenças significantes em G1T1, G1T2, G2T1 e G2T2 quando comparados os subgrupos A - B e B - C, todos com (p<0,01). Não houve diferenças significantes para a adaptação marginal vertical e horizontal antes e depois da ciclagem em todos os grupos. Na comparação de G1 e G2, houve diferença significante para a adaptação vertical e horizontal apenas no subgrupo B, nos dois tempos, ambos com (p <0,01). Na comparação dos subgrupos A, B e C, houve diferenças significantes em G1 antes e depois; e G2 antes e depois, quando comparados os subgrupos A - B e B - C, todos com (p<0,01) para a adaptação vertical e horizontal. Já para a adaptação horizontal, esta comparação foi significante apenas em G2 antes e depois, ambos com (p=0,02). Em relação à resistência à fratura, a comparação entre G1 e G2, foi significante em todos os subgrupos, A e C (p<0,01), B (p=0,02). A comparação dos subgrupos A, B e C, também foi significante em relação à resistência à fratura das próteses em todos os grupos (p<0,01). Pode-se concluir que a simulação de ciclos mastigatórios teve influência significante sobre a perda de torque dos parafusos protéticos, porém não influenciou significativamente a adaptação marginal vertical e horizontal das próteses; desadaptações marginais influenciaram significativamente no afrouxamento dos parafusos protéticos; as próteses dos subgrupos A e C obtiveram resultados significantemente melhores para a adaptação marginal vertical e horizontal quando comparadas às do subgrupo B, sendo que na adaptação horizontal, as do subgrupo A tiveram resultados melhores que as do C; a quantidade e distribuição dos implantes não influenciou na perda de torque dos parafusos protéticos em todas as situações, porém teve influência significativa na adaptação marginal vertical e horizontal das próteses do subgrupo B; todas as próteses sobreviveram ao ensaio de fadiga acelerada progressiva; em relação ao ensaio de resistência à fratura, as próteses do G2, tiveram resultados significantemente melhores que as do G1, o subgrupo B obteve valores significantemente maiores de resistência na região do cantilever, quando comparadas ao subgrupos A e C; o subgrupo A obteve os menores valores de resistência. / The objective of this study was evaluate two different designs of full-arch implant-supported fixed dentures, comparing the infrastructure manufacturing techniques: CAD-CAM technology, conventional casting and Articulated Bar. After thermomechanical cycling, were analyzed prosthetic screws loosening and vertical and horizontal marginal adaptation. In the end, the prostheses were submitted to tests of progressive accelerated fatigue and fracture resistance. Were made 48 implant-supported fixed dentures, which initially were divided into two groups, G1 - conventional protocol; G2 - \"All-on-4\". According to the technique of manufacturing infrastructure, these groups were divided into three subgroups: A - CAD-CAM technology; B - conventional casting; C - Articulated bar, providing six different samples: G1A, G1B, G1C, G2A, G2B e G2C (n=8). All samples were evaluated in the vertical and horizontal marginal adaptation using MicroCT before and after the thermomechanical cycling (2,000,000 cycles). The loosening of the prosthetic screws was analyzed before (T0), 1,000,000 (T1) and 2,000,000 cycles (T2). After this test, the prostheses were submitted to progressive accelerated fatigue test (n = 8) and sequentially fracture resistance test (n = 6). The prosthetic screw loosening has significant difference for all time compared (p <0.01), except in G2B where the comparison between T1 - T2 showed no significant difference (p = 0.72). The comparison between G1 and G2 was not significant. The comparison between subgroups A, B and C had significant differences in G1T1, G1T2, G2T1 and G2T2 compared subgroups A - B, B - C, all of (p <0.01). There were no significant differences for vertical and horizontal marginal adaptation before and after cycling in all groups. Compared to G1 and G2, there was a significant difference for vertical and horizontal adjustment only in the subgroup B in two stages, both (p <0.01). In the comparison of subgroups A, B and C, there were significant differences G1 before and after; and G2 before and after, when compared subgroups A - B, B - C, all of (p <0.01) for vertical and horizontal adaptation. As for the horizontal adaptation, this comparison was significant only in G2 before and after, with both (p = 0.02). With regard to fracture resistance, the comparison between G1 and G2 was significant in all subgroups, A and C (p <0.01), B (p = 0.02). The comparison of subgroups A, B and C was also significant compared to the fracture resistance of the prosthesis in all groups (p <0.01). It can be concluded that the simulation of mechanical cycling had significant influence on the loosening of prosthetic screws, but did not significantly influence the vertical and horizontal marginal fit of the prosthesis; marginal adaptation significantly influenced the loosening of prosthetic screws; the prostheses of the subgroups A and C had significantly better results for the vertical and horizontal marginal adaptation when compared to the subgroup B, and in the horizontal adaptation, the sub-group A had better results than those of C; the amount and distribution of the implants did not affect the prosthetic screws loosening in all situations, but had significantly influence in vertical and horizontal marginal adaptation of subgroup B prostheses; all samples survived in progressive accelerated fatigue test; in relation to the fracture resistance test, the prosthesis G2, had significantly better results than the G1, the B subgroup achieved significantly higher values of resistance in the cantilever region, when compared to subgroups A and C; the subgroup C obtained the smallest resistance.
204

Printed circuit board computer-aided design in Hong Kong.

January 1987 (has links)
by Mok Chun-Hung. / Thesis (M.B.A.)--Chinese University of Hong Kong, 1987. / Bibliography: leaves 72-75.
205

Marketing of technology-based products: a case study of CAD/CAM software companies in Hong Kong.

January 1995 (has links)
by Tsang Tze-kon. / Thesis (M.B.A.)--Chinese University of Hong Kong, 1995. / Includes bibliographical references (leaves 50-51). / ABSTRACT --- p.iii / TABLE OF CONTENTS --- p.v / ACKNOWLEDGEMENT --- p.vii / CHAPTER / Chapter 1. --- INTRODUCTION / Chapter 1.1 --- Technology-based Products --- p.1 / Chapter 1.2 --- Computer-Aided Design & Computer-Aided Manufacturing (CAD/CAM) --- p.2 / Chapter 1.3 --- Research Objectives --- p.3 / Chapter 2. --- LITERATURE REVIEW / Chapter 2.1 --- Characteristics of High-Technology Market --- p.4 / Chapter 2.2 --- Non-technical Approach to Marketing High-Tech --- p.5 / Chapter 2.3 --- Importance of Pre-Sale & Post-Sale Services --- p.7 / Chapter 2.4 --- Technical Life Cycle --- p.7 / Chapter 2.5 --- Innovation-Driven versus Market-Driven --- p.9 / Chapter 2.6 --- Product Positioning of Technology-based Products --- p.10 / Chapter 2.7 --- Country -of- Origin Issue --- p.12 / Chapter 3. --- RESEARCH METHODOLOGY / Chapter 3.1 --- Exploratory Research --- p.14 / Chapter 3.2 --- Descriptive Research --- p.14 / Chapter 4. --- FINDINGS / Chapter 4.1 --- Case Studies --- p.16 / Chapter 4.1.1 --- Company C / Chapter 4.1.2 --- Prima Design System Ltd. / Chapter 4.1.3 --- Splineware Graphics Systems Co. Ltd. / Chapter 4.2 --- Findings of Survey & Data Analysis --- p.29 / Chapter 4.2.1 --- Sample Characteristics / Chapter 4.2.2 --- Factors Affecting Buying Decision / Chapter 4.2.3 --- Country -of- Origin Issue / Chapter 5. --- DISCUSSION / Chapter 5.1 --- Marketing Strategy of Company C --- p.31 / Chapter 5.2 --- Marketing Strategy of Prima Design Systems Ltd. --- p.33 / Chapter 5.3 --- Marketing Strategy of Splineware Graphics Systems Co. Ltd. --- p.35 / Chapter 5.4 --- Role of the Hong Kong Industrial Technology Centre Corporation --- p.36 / Chapter 5.5 --- Limitations of Case Studies --- p.37 / Chapter 5.6 --- Limitations of Questionnaire Survey --- p.38 / Chapter 5.7 --- Country-of-Origin Issue --- p.39 / Chapter 5.8 --- Future of Technology-based Companies in Hong Kong --- p.40 / Chapter 6. --- RECOMMENDATIONS & CONCLUSIONS / Chapter 6.1 --- Recommendations --- p.42 / Chapter 6.2 --- Conclusions --- p.43 / APPENDICES / Appendix A: Questionnaire for Case Study --- p.44 / Appendix B: Questionnaire for Descriptive Research --- p.46 / Appendix C: Survey Findings --- p.48 / BIBLIOGRAPHY --- p.50
206

Comparative assessment of conventional vs. CAD/CAM complete denture fabrication techniques on patient satisfaction, quality of life and prosthesis biofilm

Jia-mahasap, Wissanee 01 May 2017 (has links)
Objectives: The primary objective was to assess the impact of two denture fabrication techniques, conventional and CAD/CAM, on oral health-related quality of life (OHRQoL) and patient satisfaction in complete denture wearers. The secondary objective was to compare the level of microorganisms present on complete dentures from the two fabrication techniques. Methods: Twenty-eight completely edentulous subjects (16 men and 21 women, age range from 49 to 87 years old.), who had been edentulous for at least 6 months, were wearing ill-fitting complete dentures, or unsatisfied with their existing complete dentures were recruited. Subjects were randomized to conventional and computer-aided design/ computer-aided manufacturing (CAD/CAM) treatment groups. Subjects in both groups were given the OHIP-EDENT (Oral Health Impact Profile for Edentulous Patients) and patient satisfaction questionnaires to record the data at baseline and at 1 month post-delivery of the new prostheses. Plaque samples were collected from intaglio surfaces of maxillary complete dentures at 1 month post-delivery to culture for any colonization of bacteria and/or yeasts. Results: There was a significant reduction in OHIP-EDENT scores within both treatment groups at the 1 month follow-up (p < 0.05). There was also a significant reduction in almost all OHIP-EDENT domains scores at 1 month. Gender was significantly associated with OHIP-EDENT score at baseline (p = 0.0419) and at 1 month (p = 0.0152). Female subjects tend to have higher OHIP-EDENT scores than male subjects. There was no significant difference in patient satisfaction between treatment groups both at baseline and at the 1 month visit for almost all aspects of satisfaction (p> 0.05). Appearance of maxillary denture was the only significant difference in patient satisfaction across treatment groups (p = 0.0213). The comparisons of microbial counts showed no significant difference between treatment groups. Conclusions: There were no significant difference on oral health-related quality of life (OHRQoL) and patient satisfaction between two treatment groups at baseline and 1 month. There was no significant difference in microbial counts between two treatment groups.
207

Desenvolvimento de uma técnica de desenho digital e impressão em 3D de placas oclusais e sua aplicabilidade no tratamento de pacientes com disfunção temporomandibular / Development of a technique of digital design and 3D printing of occlusal splints and its applicability in the treatment of patients with temporomandibular disorders

Vasques, Mayra Torres 11 December 2018 (has links)
O uso de novas tecnologias na odontologia, como a técnica CAD/CAM, promete ser uma opção relevante no que diz respeito à confecção das placas oclusais, empregadas no tratamento de disfunções temporomandibulares. O objetivo desta pesquisa foi desenvolver uma técnica para desenho e confecção de placas oclusais pelo método CAD/CAM, em impressora 3D, e verificar seus resultados clínicos no tratamento de pacientes com disfunções temporomandibulares. Para o desenho das placas foi desenvolvida uma metodologia de desenho digital (CAD), utilizando o software Meshmixer® (Autodesk, USA), e de registro das relações maxilo-mandibulares. A partir dessa metodologia iniciou-se um estudo clínico randomizado comparativo entre as placas CAD/CAM produzidas em impressora 3D e placas produzidas convencionalmente em laboratório. O estudo foi realizado em duas etapas, 18 pacientes foram avaliados de acordo com os critérios de inclusão e exclusão. Na Etapa 1 (n=18) foram realizados testes técnicos comparativos das duas placas em relação à dor, por meio da Escala Visual Analógica; atividade muscular; ajuste interno; báscula; conforto; tempo de instalação; pontos de contato oclusal. Todos os pacientes da amostra utilizaram os dois tipos de placas. Na Etapa 2, estes pacientes foram divididos randomicamente em dois grupos para o estudo clínico randomizado (estudo cego): Grupo IMP (n=9) (placas impressas) e grupo LAB (n=9) (placas convencionais laboratoriais). Os grupos foram avaliados após 1 mês de uso, por meio dos Questionários, RDC/TMD, SF-36, escala visual de dor EVA, e pelos pontos de contato oclusais. Os dados foram avaliados estatisticamente usando os testes de Wilcoxon, de Mann-Whitney, e de Kruskal-Wallis nas análises quantitativas; os testes Qui-Quadrado e Exato de Fisher, nas variáveis categóricas. Os resultados mostraram que houve diferenças significativas (P-valor<0.05) nas avaliações para conforto, ajuste interno e tempo de confecção das placas, a favor das placas impressas. Nas demais avaliações, os grupos foram equivalentes (não- significantes). Concluiu-se que foi possível desenvolver uma técnica para desenho e confecção de placas oclusais pelo método CAD/CAM, em impressora 3D, e que o desempenho clínico foi equivalente entre as placas convencionais e impressas, sendo que estas se mostraram superiores quanto ao conforto e quanto à adaptação da superfície interna da placa, mostrando ser este um método possível e viável economicamente. / The use of new technologies in dentistry, as the CAD/CAM technique, promises to be a relevant option concerning the manufacture of occlusal splints for temporomandibular disorders treatment. The aim of this research was to develop a technique for design and manufacture occlusal splints using the CAD/CAM method and 3D printer and verify the clinical results in the treatment of temporomandibular disorders patients. It was developed a technique for occlusal splint design a using the software Meshmixer® (Autodesk, USA) and a technique to register the jaws relationship. From this method, it was started a Randomized Clinical Trial (RCT) to compare splints made through the CAD/CAM technique and others made conventionally in a dental lab. The study was performed in two steps, 18 patients were selected based on the inclusion/exclusion criteria. In Step 1 (n=18) patients were comparatively evaluated, using both splints, in relation to pain, using the visual analog scale; internal adjustment of the splint; patients comfort; time spent to deliver the appliance and occlusal contacts pattern. In Step 2, these patients were allocated in two groups (n=9 each group) randomly to the RCT be performed (blind study): Group IMP - printed splints and Group LAB (conventional lab splints). Both groups were assessed after 1 month using the splint using RDC/TMD and SF-36 questionnaires, the visual analog scale for pain, and occlusal contacts pattern. The data were statistically evaluated using Wilcoxon, Mann-Whitney, and Kruskal-Wallis test for qualitative analyses and Qui-square and Fisher´s exact tests for categorical variables. The results showed significant statistical differences (p-value<0.05) in favor of printed occlusal splints, related to patients\' comfort, internal adjustment, and time spent to deliver the appliance. All other assessments were equivalents (not significant). It was concluded that it was possible to develop a technique to design and manufacture occlusal splints using CAD/CAM and 3D printer, and furthermore the clinical performance was equivalent comparing conventional and printed occlusal splints, being the printed splints superior to conventional splints in relation to comfort and internal adjustment, proving this is a possible and economically viable method.
208

Obrobitelnost kompresních kol z titanových slitin / On the Machinability of Compression Titanium-Alloys Wheels

Pepin, Faustin January 2012 (has links)
Nespornou vyhodou počítačem podporované výroby (CAM) je výrazná časová úspora při přípravě obráběcího programu. Asociativita je jedním z řešení, její místo v rámci přípravy výrobku se nachází mezi hlavní konstrukcí a technologií podniku. Pro studium asociativity byl použity CAD/CAM modely kompresoru, který díky své komplexní geomtrii posloužil jaky dobrý příklad. Tato práce se podtrhuje omezené možnosti asociativity, především pokud jde o realizaci obráběcího programu pro součást tvořenou více prvky. Dále v této studii budou prezentovány jisté možnosti zlepšení procesu. Studie asociativity v této práci je zaměřena především na obrábění, tedy její aplikace jsou využívány zejména ve oborech jako je automobilový průmysl, letectví, kosmický průmysl či stavebnictví. Kompresor studovaný v této práci je vyroben ze slitiny titanu Ti-6Al-4V a jedná se o součást využívanou v kosmickém průmyslu. Jelikož se jsou jeho rozměry velmi malé, jsou pro jeho obrábění nezbytné velmi přesné nástroje a vysoké řezné rychlosti. Tato práce představuje odlišné strategie obrábění navrhnuté pro výrobu kompresoru, společně s analýzou výsledků. Po počáteční přípravě výroby následují dvě hlavní etpy : editace programu v CATII V5 a jeho ověření v NCSimul8.
209

APLICAÇÃO DA META-HEURÍSTICA GRASP PARA O PROBLEMA DE CORTE DE ESTOQUE BIDIMENSIONAL ATRAVÉS DE APLICATIVOS CAD

Bianco, Clicéres Mack Dal 09 August 2010 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The PCE (Cutting Stock Problem) is to cut a set of objects available in stock to produce a quantity of items with specific sizes in order to optimize the raw material. Such problems have numerous industrial applications and has been widely studied in literature. The PCE's are classified as combinatorial optimization problems, because depending on the amount of requested items can be combined in numerous ways within an object forming an arrangement of cut. The number of possible combinations is, in practice, very high, requiring well-developed techniques are developed to determine an optimum arrangement. In defining the arrangements of cut is needed to graph the components of the problem and in this case, the tools used in the implementation must have the ability to manipulate geometric. In this paper, the combinatorial problem was approached from the GRASP heuristic technique and as a tool of manipulation was employed geometric applications deployed in an environment of Computer Aided Design (CAD). Furthermore, we proposed an integration of arrays of cutting systems with computer-aided manufacturing (CAM). The analysis of performance of the developed algorithm considers data provided by a furniture industry in the region of Santa Maria. The results obtained by the algorithm were compared to results generated by specialized software, consisting that the proposed method presents a similar performance, which demonstrates the feasibility of using CAD tools to implement solutions in the industry of PCE small and medium businesses. / O Problema de Corte de Estoque Bidimensional (PCEB) consiste em cortar um conjunto de objetos disponíveis em estoque para produzir uma quantidade de itens com tamanhos específicos, de modo a otimizar a matéria prima. Tais problemas têm inúmeras aplicações industriais e tem sido amplamente estudados na literatura. Os PCEB são classificados como problemas de otimização combinatória, pois, dependendo da quantidade de itens solicitados, podem ser combinados de inúmeras maneiras dentro de um objeto formando um arranjo de corte. O número de combinações possíveis é, na prática, muito elevado, exigindo que técnicas bem elaboradas sejam desenvolvidas para determinar um arranjo ótimo. Na definição dos arranjos de corte é necessário representar graficamente os componentes do problema e neste caso, as ferramentas empregadas na implementação devem apresentar capacidade de manipulação geométrica. Neste trabalho, o problema combinatório foi abordado a partir da técnica heurística GRASP e como ferramenta de manipulação geométrica empregou-se aplicativos implementados em ambiente de Projetos Auxiliado por Computador (CAD). Além disso, foi proposta uma integração dos arranjos de cortes com sistemas de Manufatura Auxiliador por Computador (CAM). A analise de desempenho do algoritmo desenvolvido considera dados fornecidos por uma indústria moveleira da região de Santa Maria. Os resultados obtidos pelo algoritmo foram comparados aos resultados gerados por software especializado, constando-se que a metodologia proposta apresenta um desempenho semelhante, o que demonstra a viabilidade o uso das ferramentas CAD para implementação de soluções PCE em indústria de pequeno e médio porte.
210

EFEITO DE TRATAMENTOS TÉRMICOS NA RESISTÊNCIA FLEXURAL DE UMA VITROCERÂMICA REFORÇADA POR LEUCITA / EFFECT OF HEAT TREATMENTS ON FLEXURAL STRENGHT OF A LEUCITE REINFORCED GLASS CERAMIC

Aurelio, Iana Lamadrid 06 June 2014 (has links)
Fundação de Amparo a Pesquisa no Estado do Rio Grande do Sul / The aim of this study was to investigate the effect of heat treatments on the flexural strength, surface roughness and crystalline structure of a leucite reinforced glass ceramic (IPS Empress CAD, Ivoclar Vivadent, Liechtenstein). A hundred fifty (150) discs were machined by CEREC inLab MC XL (Sirona, Alemanha) and distributed into five groups, n=30: C (control, no heat treatment), A-575 (annealed at 575°C during 15 min, followed by slow cooling and furnace opening at 200°C), A-790 (annealed at 790°C during 15 min, followed by slow cooling and furnace opening at 200°C), G (glazed at 790°C during 1,5 min, followed by fast cooling - immediate furnace opening) and GM (modified glaze, at 790°C during 1,5 min, followed by slow cooling and furnace opening at 200°C). Biaxial flexural strength was determined by the piston-on-three ball test (ISO 6872/2008). Weibull modulus (m) and characteristic strength (σ0) were calculated from the results. The surface roughness (Ra and Rz) was measured before and after the treatments. One specimen from each group was used for X-ray diffraction. A-790 produced the highest values of fracture strength (211.7 MPa). The values of σ0 obtained for the other tested regimens (A-575: 167.9 MPa, GM: 157.7 MPa and G: 153.7 MPa) were lower than those from the control group (187.7 MPa). The value of m was statistically similar between the groups. All heat treatments were able to reduce the mean roughness (Ra) of the specimens. The mean amplitude (Rz), showed a significant reduction only for the groups submitted to the annealing treatments (A-575 e A-790). The X-ray diffraction analysis revealed no changes in the crystalline phase (tetragonal leucite) of the material after the different heat treatments. Variations in the size of the leucite crystallites after thermal cycles were not significant. Thus, high values of fracture strength and decreased surface roughness for a leucite reinforced glass ceramic are achieved by annealing above the glass transition (Tg=625 ± 20ºC) after machining. This regimen (A-790) was capable to produce favorable structural reorganization of the material, without modifying its original crystalline structure. Annealing bellow the glass transition (A- 575) and thermal cycle for glazing (G and GM) significantly reduced the strength of the material. / A proposição deste estudo foi investigar o efeito de tratamentos térmicos na resistência flexural biaxial, na rugosidade superficial e na estrutura cristalina de uma vitrocerâmica reforçada por leucita (IPS Empress CAD, Ivoclar Vivadent, Liechtenstein). Para tanto, 150 discos foram obtidos por usinagem em equipamento CEREC inLab MC XL (Sirona, Alemanha) e distribuídos em cinco grupos, de n=30: C (controle, sem tratamento térmico), A-575 (annealing à 575°C por 15 min, seguido de resfriamento lento com abertura do forno em 200°C), A-790 (annealing à 790°C por 15 min, seguido de resfriamento lento com abertura do forno em 200°C), G (glazeamento à 790°C por 1,5 min, seguido de resfriamento rápido com abertura imediata do forno) e GM (glazeamento modificado à 790°C por 1,5 min, seguido de resfriamento lento com abertura do forno em 200°C). A resistência flexural dos discos foi determinada pelo teste piston-on-three ball, conforme normas da ISO 6872/2008 e os dados submetidos à análise de Weibull para cálculo do módulo de Weibull (m) e da resistência característica (σ0). A rugosidade superficial (Ra e Rz) antes e após os tratamentos foi mensurada. Um espécime de cada grupo foi utilizado para difração de raios-X. O regime A-790 produziu os maiores valores de resistência à fratura (211,7 MPa). Os valores de σ0 promovidos pelos demais ciclos testados (A-575: 167,9 MPa, GM: 157,7 MPa e G: 153,7 MPa) foram inferiores aos do grupo controle (187,7 MPa). O valor de m não diferiu significativamente entre os grupos. Todos os tratamentos térmicos foram capazes de reduzir a rugosidade média (Ra) dos espécimes. Já os valores de amplitude média do perfil (Rz), apresentaram redução significativa apenas para os grupos submetidos à annealing (A-575 e A-790). A análise de difração de raios-x revelou não ter havido mudanças de fase cristalina (leucita tetragonal) do material após os tratamentos térmicos. As alterações no tamanho dos cristalitos de leucita após a realização dos ciclos térmicos não foram expressivas. Sendo assim, maiores valores de resistência à fratura e diminuição da rugosidade superficial para uma vitrocerâmica reforçada por leucita puderam ser conseguidos através de annealing acima da transição vítrea (Tg=625 ± 20ºC) após a usinagem. Tal regime (A-790) foi capaz de produzir reorganização estrutural favorável do material, sem contudo modificar sua estrutura cristalina original. Annealing abaixo da transição vítrea (A-575) e regimes de glazeamento (G e GM) reduziram significativamente a resistência do material.

Page generated in 0.0283 seconds