• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1848
  • 6
  • Tagged with
  • 1854
  • 1854
  • 1854
  • 1492
  • 326
  • 265
  • 221
  • 220
  • 196
  • 169
  • 165
  • 159
  • 136
  • 135
  • 124
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Avaliação cromática de três resinas para base de próteses após imersão em alimentos líquidos / Chromatic evaluation of three denture base resins after immersion in liquid foods.

Sepulveda-navarro, Wilmer Fabian 08 November 2007 (has links)
Made available in DSpace on 2017-07-24T19:22:07Z (GMT). No. of bitstreams: 1 Wilmer Fabian.pdf: 1250076 bytes, checksum: dc6d549d19b660234c668b167e06c364 (MD5) Previous issue date: 2007-11-08 / The purpose of this study was to determine the color stability of two heat-cured denture base acrylic resins (Lucitone 550 and Vipi Cril) and one nylon denture base material (Transflex) immersed in four liquid foods (coffee, cola, red wine and distilled water). Forty specimen disks of each brand, with a diameter of 20.0 mm and a thickness of 3.0 mm were prepared. Each specimen was suspended in the liquid foods with dental floss so that it did not contact the container or other specimens. The specimens were stored in distilled water for 24 h at 37°C. At that time (T0) the color of all specimens was measured with a spectrophotometer (Varian Cary 100). After 15-day (T1) and 30-day (T2) periods of immersion in the liquid foods color of the specimens was measured again with the spectrophotometer. Color measurements were recorded using the CIEL a b (Commission Internationale de L’ Eclairage) system with D65 (day light) light. Mean ΔE (color changes) values were calculated for each material and compared statistically with a two-way analyses of variance and calculating Bonferroni intervals at 0.95. In ΔE T0T1 and ΔE T0T2 the most severe discoloration was apparent with red wine when compared to the specimens stored in distilled water (P< 0.0001). Coffee was the second staining liquid food which have affect both acrylic and nylon denture base materials. Transflex also showed significant color change after immersion in cola (P < 0.001). In ΔE T1T2 only red wine promoted significant discoloration of all resins (P < 0.0001). From the conclusions of this study, the greatest chromatic change was exhibited by specimens immersed in red wine, followed by coffee. ΔE values of the specimens converted to NBS (National Bureau of Standard) units, showed a visually perceptible color change by these two liquid foods (red wine and coffee). / objetivo deste estudo foi determinar a estabilidade de cor de duas resinas acrílicas (Lucitone 550 e Vipi Cril) e de um material à base de náilon (Transflex) para base de próteses, imersos em três alimentos líquidos (café, refrigerante de cola e vinho tinto, e água destilada, como controle). Quarenta corpos-de-prova em forma de discos de cada marca comercial, com diâmetro de 20,0 mm e espessura de 3,0 mm foram confeccionados. Cada corpo-de-prova foi suspenso dentro do alimento líquido com o uso de um fio dental impedindo o contato com o recipiente ou outros corpos-deprova. Os corpos-de-prova foram armazenados em água destilada por 24 h (T0) a 37 °C. Neste tempo T0, a cor dos corpos-de-prova foi mensurada com espectrofotômetro (Varian Cary 100). Após 15 dias (T1) e 30 dias (T2) de imersão nos alimentos líquidos, a cor dos corpos-de-prova for mensurada novamente com o espectrofotômetro. A mensuração de cor foi registrada usando o sistema CIE L*a*b* (Commission Internationale de L’ Eclairage), com iluminante D65 (luz do dia). Os valores das médias de ΔE (alterações de cor) foram calculados para cada material e comparados estatisticamente com análise de variância de dois fatores e confirmado pelo teste de Bonferroni com intervalos de 0,95. Em ΔE T0T1 e ΔE T0T2 as maiores alterações de cor foram obtidas com o vinho tinto quando comparadas com as dos corpos-de-prova imersos em água destilada (P< 0,0001). O café foi o segundo alimento líquido que alterou a cor tanto das resinas acrílicas quanto da resina à base de náilon. Transflex também demonstrou alteração de cor significativa após a imersão em refrigerante de cola (P < 0,0001). Em ΔE T1T2, somente o vinho tinto promoveu alteração de cor significativa em todas as resinas (P < 0,0001). As conclusões deste estudo demonstram que a maior alteração cromática foi provocada pelo vinho tinto, seguido pelo café. Os valores de ΔE dos corpos-de-prova, convertidos a unidades NBS (National Bureau of Standard), demonstraram alteração de cor visualmente perceptíveis por ambos os alimentos líquidos (vinho tinto e café).
42

Correlações entre Doença Periodontal e Aterosclerótica Coronariana:presença de anticorpos Anti-Toxoplasma gondii em amostras de sangue, catéter e saliva humana. / Correlations between Periodontal Disease and Coronary Artery: presence of anti-Toxoplasma gondii antibodies in blood samples, catheter and human saliva

Nascimento, Caroline Michelis 31 August 2012 (has links)
Made available in DSpace on 2017-07-24T19:22:25Z (GMT). No. of bitstreams: 1 Caroline Michelis Nascimento.pdf: 1850538 bytes, checksum: ef9b5b6eb0f2144523223dd6c55ee614 (MD5) Previous issue date: 2012-08-31 / The occurrence of oral diseases is related to habits, stress levels, diet and emotional factors. The oral cavity is the site of entry for many microorganisms and are manifested niche where the first symptoms of a number of diseases of systemic character. Periodontal disease (PD) is a chronic infectiousinflammatory that affects the supporting tissues of the teeth and support, and toxoplasmosis, a protozoonosis worldwide distribution, caused by an intracellular parasite Toxoplasma gondii, which infects 50% of the world population and has its transmission by feeding undercooked meats. The aim of this study was to assess the degree of impairment of periodontal diseases in humans checking the correlation with toxoplasmosis and Coronary Artery Disease (CAD). Sixty-four patients underwent coronary angiography and were divided into two groups: patients with CAD (n = 47) and patients without CAD (n = 17). The results of angiography of patients with / without CAD demonstrated that the category of coronary obstructive lesions between 25% and 50% and> 50% the number of injuries among experimental groups in the right coronary artery, anterior and circumflex were statistically different (p = 0.0001) concluding that atherosclerosis can cause lesions in various arteries varying degree at the same time. The number of patients with hyperglycemia in the group with coronary disease, caused by stress hyperglycemia during hospitalization of patients with acute myocardial infarction without history of diabetes, show a higher rate of glycemic alterations in these patients (48.9%). Patients with /without CAD, have also been analyzed qualitatively for the presence or absence of IgG, IgM and IgA anti-toxoplasma in serum, saliva and blood samples collected during angiography catheter. Although they are not statistically different among the experimental groups, the rates of absorbance in serum (p =0,476) and saliva (p = 0.7632) were higher for patients without CAD, indicating that the presence of antibodies to Toxoplasma gondii is higher in patients without CAD than in patients with CAD. Regarding the parameters of periodontal health the number of patients with bleeding sites and the number of bleeding sites was higher in patients with CAD (p = 0.0491 and p = 0.002, respectively), with the average number of sites with exudate higher in the group with no difference DAC (p = 0.6052) and number of missing teeth larger than in the group without CAD (p = 0.0001), suggesting a correlation between the parameters of oral and periodontal health with coronary atherosclerosis. The results suggest the correlation of oral problems systemic conditions with high prevalence in the population in case of toxoplasmosis and coronary atherosclerosis. / A ocorrência de doenças bucais está relacionada aos hábitos, aos níveis de estresse, à aliment ão e aos fatores emocionais. A cavidade oral é o local de entrada para diversos microrganismos e o nicho onde se manifestam os primeiros sintomas de uma série de doenças de caráter sistêmico. A doença periodontal (DP) é uma doença infecto-inflamatória que acomete os tecidos de suporte e sustentação dos dentes, e a toxoplasmose, uma protozoonose de distribuição mundial, causada pelo Toxoplasma gondii um parasita intracelular, que infecta 50% da população mundial e tem sua transmissão através da alimentação de carnes mal cozidas. O objetivo desta pesquisa foi avaliar o grau de comprometimento de doenças periodontais em humanos verificando a correlação com a toxoplasmose e a Doença Arterial Coronariana (DAC). Sessenta e quatro pacientes foram submetidos a cinecoronariografia e divididos em dois grupos: pacientes com DAC (n=47) e pacientes sem DAC (n=17). Os resultados da cinecoronariografia de pacientes com/sem DAC demonstraram que na categoria das lesões obstrutivas coronarianas entre 25% e 50% e >50% o número de lesões entre os grupos experimentais nas artérias coronária direita, interventricular anterior e circunflexa foram estatisticamente diferentes (p = 0.0001) concluindo que aterosclerose pode provocar lesões de grau variado em várias artérias ao mesmo tempo. O número de pacientes com hiperglicemia no grupo que apresenta doença coronariana, causada por hiperglicemia de estresse durante admissão hospitalar de pacientes com infarto agudo do miocárdio sem histórico de diabetes, demonstram uma elevada taxa de alterações glicêmicas nesses pacientes (48.9%). Os pacientes com/sem DAC, também foram analisados qualitativamente para presença ou ausência de anticorpos IgG, IgM e IgA anti-toxoplasma em amostras de soro, saliva e em amostras sanguíneas obtidas com cateter durante coronariografia. Apesar de estatisticamente não serem diferentes entre os grupos experimentais, os índices de absorbância no soro (p=0.476) e na saliva (p=0.7632) foram maiores para os pacientes sem DAC, indicando que a presença de anticorpos anti Toxoplasma gondii é mais elevado em pacientes sem DAC do que em pacientes com DAC. Em relação aos parâmetros da saúde periodontal o número de pacientes com sítios sangrantes e o número de sítios sangrantes foi maior nos pacientes com DAC (p=0.0491 e p=0.002, respectivamente), com número médio de sítios com exsudato maior no grupo com DAC sem diferença estatística (p=0.6052) e número de dentes perdidos maior que no grupo sem DAC (p=0.0001), sugerindo uma correlação entre os parâmetros da saúde oral e periodontal com a doença aterosclerótica coronariana. Os resultados sugerem a correlação de problemas bucais, com condições sistêmicas de alta prevalência na população no caso da toxoplasmose e a aterosclerose coronariana.
43

Comparação de duas técnicas de fotopolimerização nas propriedades de contração e temperatura de polimerização de uma resina de incremento único por meio das redes de Bragg / Comparison of the contraction and polymerization temperature of a single increment resin by means of the Bragg networks using two photopolymerization techniques

Costa, Manoela Maria Machado 16 February 2018 (has links)
Submitted by Eunice Novais (enovais@uepg.br) on 2018-05-21T18:29:42Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Manoella Maria Machado Costa.pdf: 2056005 bytes, checksum: cea06c624bdf599dba9ef2d9e2c099ab (MD5) / Made available in DSpace on 2018-05-21T18:29:42Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Manoella Maria Machado Costa.pdf: 2056005 bytes, checksum: cea06c624bdf599dba9ef2d9e2c099ab (MD5) Previous issue date: 2018-02-16 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O objetivo do estudo foi avaliar a influência dos modos de fotoativação Contínua e Ramp nas propriedades de contração de polimerização e alteração térmica de uma resina composta Filtek™Bulk Fill Flow. Foram selecionados 30 dentes terceiros molares hígidos nos quais foi preparada uma cavidade de Classe I oclusal (4 mm de comprimento x 4 mm de largura x 4 mm de profundidade). Para o posicionamento dos sensores de Bragg, um sensor foi posicionado no sentido mésio-distal diretamente em contato com a resina que mediu a deformação de contração, e outro no interior de uma agulha hipodérmica no sentido vestíbulo-lingual que mediu somente a temperatura. Os dentes foram restaurados com a resina Filtek ™ Bulk Fill Flow de acordo com as recomendações do fabricante. Posteriormente, utilizou-se uma fórmula para obter o valor de deformação pura do material em μstrain. A análise estatística foi obtida por meio de análise de variância e teste t de Student. Os resultados revelaram não haver diferenças estatísticas significativas para os valores de contração entre os dois protocolos de fotoativação (Contínuo e Ramp) e entre os tempos de 500s, 1500s, 2500s e 3500s. Ao final de 3500s observou-se uma tendência à estabilização das curvas para ambos os modos de fotoativação. A fotoativação Ramp revelou maior valor de variação de temperatura (16,32°C) quando comparada à fotoativação Contínua (7,8°C). Os sensores de Bragg foram capazes de medir a alteração de contração e a variação térmica. A fotoativação contínua demorou mais para retornar ao valor inicial de temperatura (2,85 min) que a Ramp (1,65 min). Futuros estudos devem monitorar a contração de polimerização por um intervalo de tempo maior necessário para a estabilização total da curva. / The objective of this study was to evaluate the influence of Continuous and Ramp photoactivation modes on the shrinkage polymerization, and thermal change properties of a Filtek™ Bulk Fill Flow composite. 30 third molar teeth were selected. An occlusal Class I cavity (4 mm length x 4 mm wide x 4 mm depth) was prepared.For the positioning of the Bragg sensors, a sensor was positioned in the mesio-distal direction directly in contact with the composite that measured the shrinkage deformation, and another sensor inside a hypodermic needle in the lingual-lingual direction that measured only the temperature. The teeth were restored with Filtek™Bulk Fill Flow resin according to the manufacturer's recommendations. Subsequently, was used a formula to obtain the pure deformation value of the material in μstrain. Statistical analysis was obtained through analysis of variance and Student's t-test. The results showed no significant statistical differences for the shrinkage values between the two photoactivation protocols (Continuous and Ramp) and among 500s, 1500s, 2500s and 3500s times. At the end of 3500s a tendency to stabilize the curves for both modes of photoactivation was observed. The Ramp photoactivation revealed a higher value of temperature variation (16.32°C) when compared to Continuous photoactivation (7.8 °C). The Bragg sensors were able to measure the shrinkage, and the thermal variation. Continuous photoactivation took longer to return to the initial temperature value (2.85 min) than ramp (1.65 min). Future studies should monitor the shrinkage of polymerization for a longer period of time necessary for the total stabilization of the curve.
44

Avaliação do perfil citotóxico e potencial anti-inflamatório de nanopartículas de ouro / Cytotoxic profile and anti-inflammatory potential evaluation of gold nanoparticles

Sanson , Mariane Aparecida Savi 16 February 2016 (has links)
Submitted by Eunice Novais (enovais@uepg.br) on 2018-07-24T14:58:19Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Mariane A Sanson.pdf: 3058378 bytes, checksum: 43bb48ea0be645db69444ec684b43bac (MD5) / Made available in DSpace on 2018-07-24T14:58:19Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Mariane A Sanson.pdf: 3058378 bytes, checksum: 43bb48ea0be645db69444ec684b43bac (MD5) Previous issue date: 2016-02-16 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Compostos de ouro já apresentam propriedades anti-inflamatórias estabelecidas pela literatura, além de importante potencial antioxidante. A utilização do ouro na forma nanoparticulada é uma aposta promissora para o tratamento de condições inflamatórias, como a doença periodontal, pelo seu mecanismo de ação. Apesar da biocompatibilidade estabelecida do ouro, é importante atentar-se para a possibilidade de efeito tóxico do ouro na forma nanoparticulada, devido a sua maior facilidade de penetrar nos tecidos e atravessar membranas, em resposta principalmente ao seu tamanho e concentração de ouro presente. O objetivo deste estudo foi a caracterização das nanopartículas de ouro (AuNPs) de 10, 20 e 30 nm utilizadas no trabalho, bem como testar seu efeito tópico em modelos de inflamação aguda local in vivo (edema de orelha induzido por TPA e edema de pata induzido por LPS) e verificar sua citotoxicidade em cultura de fibroblastos (3T3) e macrófagos (RAW 264.7) murinos após 12, 24 e 48h pelos ensaios de MTT, VN e teste de exclusão do azul de tripan. Para a caracterização das AuNPs foram realizados os testes de espectroscopia no ultravioleta-visível (Uv-Vis), difratometria de raios-x, absorbância atômica, potencial zeta e microscopia eletrônica de varredura por canhão de emissão de campo elétrico (FEG). Os resultados dos testes de caracterização demonstraram que as nanopartículas apresentavam-se estáveis e realmente com os diâmetros de 10, 20 e 30 nm, como proposto pelo método de síntese, estando adequadas para a utilização nos testes subsequentes. No modelo de edema de orelha induzido por TPA as formulações de AuNPs em creme a 0,1% reduziu a formação do edema em 47,76%, enquanto a formulação em creme a 0,06% reduziu o edema em 33,72% após 6h. Após 24h todas as formulações testadas apresentaram redução da formação do edema, apresentando resultados sem diferença estatística em comparação ao grupo tratado com a dexametasona. No modelo de edema de pata induzido por LPS a formulação de AuNPs em creme a 0,1% foi capaz de reduzir a formação do edema em 84,46% e a formulação em creme a 0,6% reduziu em 86,57%, também sem apresentar diferença estatística em comparação ao grupo tratado com dexametasona. Quanto aos testes de viabilidade celular, os métodos do MTT e VN não foram capazes de obter resultados confiáveis, porém o teste de exclusão do azul de tripan indicou ausência de citotoxicidade das AuNPs em 12h nas culturas de fibroblastos e macrófagos. Após 24h de incubação, a maior concentração (35 mg/L) das dispersões de AuNPs nos 3 diâmetros testados reduziu a viabilidade de macrófagos, e os fibroblastos obtiveram seus valores de viabilidade celular diminuídos pela maioria das dispersões de AuNPs testadas. Após 48h de incubação, todas as concentrações e diâmetros testados das dispersões de AuNPs foram capazes de diminuir drasticamente as porcentagens de viabilidade celular tanto em fibroblastos quanto em macrófagos. / Gold compounds already demonstrated anti-inflammatory properties in previous studies, in addition to important antioxidant potential. The use of gold in nanoparticle form is promising for the treatment of inflammatory conditions such as periodontal disease, especially for its mechanism of action. Although the established gold biocompatibility, it is important to pay attention to the possible toxic effect of gold on nanoparticulate form, for its ease of penetration through the tissues and membranes, mainly in response to its size and gold concentration. The study purpose was the physical characterization of gold nanoparticles (AuNPs) of 10, 20 and 30 nm used in the experiments, in addition to test their topical effect in models of acute inflammation in vivo (ear edema TPA-induced and paw edema LPS-induced) and verify its cytotoxicity in fibroblasts and macrophages mice cell cultures after 12, 24 e 48 hours by MTT and Neutral Red assay and exclusion of trypan blue test. To characterize the AuNPs were performed the ultraviolet-visible spectroscopy, x-ray diffraction, atomic absorbance, zeta potential and Field Emission Gun Scanning Electron Microscopy (FEG). The characterization tests results shown that the nanoparticles are stable and truly presented the diameters of 10, 20 and 30 nm, as proposed by synthesis method, and so are suitable for use in subsequent experiments. In the ear edema TPA-induced model AuNPs cream formulation at 0.1% reduced edema formation at 47.76%, while the cream formulation at 0.06% reduced 33.72% of edema after 6 hours. After 24 hours all formulations tested showed a reduction of edema formation, presenting results with no statistical difference compared to the group treated with dexamethasone. In LPS-induced paw edema model the AuNPs cream formulation at 0.1% was able to reduce edema formation in 84.46% and cream formulation at 0.6% decreased 86.57%, also without showing statistical difference compared to the group treated with dexamethasone. In viability tests, the MTT and Neutral Red methods were not able to obtain reliable results, but exclusion trypan blue test indicated no cytotoxicity of AuNPs after 12h in fibroblasts and macrophages cell cultures. After 24h incubation, the dispersions of AuNPs in 3 diameters at the highest concentration (35 mg/L) reduced the macrophages viability and fibroblast viability decreased with most of the tested AuNPs dispersions. After 48h all tested AuNPs dispersions concentrations and diameters were able to reduce the percentages of fibroblasts and macrophages cell viability.
45

An?lise da proserva??o de 273 pulpotomias em dentes permanentes : estudo retrospectivo

Kunert, Gustavo Golgo 20 March 2015 (has links)
Submitted by Setor de Tratamento da Informa??o - BC/PUCRS (tede2@pucrs.br) on 2015-05-07T13:18:33Z No. of bitstreams: 1 468066 - Texto Completo.pdf: 1590461 bytes, checksum: 94289ddea3d1a9722974c878f05d622b (MD5) / Made available in DSpace on 2015-05-07T13:18:33Z (GMT). No. of bitstreams: 1 468066 - Texto Completo.pdf: 1590461 bytes, checksum: 94289ddea3d1a9722974c878f05d622b (MD5) Previous issue date: 2015-03-20 / Conservative treatments of pulp are standard approaches of dentistry, both in primary teeth, as the permanent. Among the therapeutic, pulpotomy is reported in the literature as a quick option, easy to perform, affordable and with high potential for success, when correctly indicated. However, the lack of reliable diagnostic methods for pulp indications and clinical and radiographic parameters harsh for your proservation, to make before these uncertainties, a technique rarely used and implemented as definitive treatment in endodontics. Making a historical reflection, we can see great scientific advances in materials developed to conservative treatments. However, the factors that act directly on the success or failure and longevity of pulpotomy, are still unclear to our knowledge. Thus, the aim of this study was to try to clarify and understand this, from a retrospective study. Initially, the first article of this thesis was selected for a case of dens invaginatus type 3 with still open apex. Conservative treatment in one of the teeth and a classical approach to endodontic pulp necrosis was adopted in other. The invaginatus dens is an anomaly stage of tooth formation, which promotes many structural changes in the dental organ, offering great difficulties when conventional endodontic treatment is required. As a result, was executed endodontic treatment with calcium hydroxide exchanges in the main tooth and the tooth pulpotomy in invaginated, inducing its apicog?nese. After 21 years of clinical and radiographic follow-up, we observed the injury has healed and the complete root formation. The preservation of pulp vitality, followed by the formation of dentin bridge in pulpotomizado tooth, proved to be a viable alternative and definitive treatment. In the second article of the thesis, we seek a retorspectiva analysis of outcome. Reevaluated 273 pulpotomies in permanent teeth performed by a single professional, specialist in endodontics, and verify the influence of clinical, radiographic and systemic in proservation and determination of success or failure in pulpotomy. Data were analyzed using Cox regression test and Fisher's Exact Test (p = 0.05) for a period ranging from 1 to 29 years of follow up. We can conclude that pulpotomy can be performed at any age, without statistical correlation with the systemic problems. The absence of clinical symptoms and radiographic changes of peri-implant tissues, followed by the presence of dentin bridge and hermetic coronal sealing, are indicative reliable in proservation. / Os tratamentos conservadores da polpa s?o abordagens rotineiras da odontologia, tanto nos dentes dec?duos, quanto nos permanentes. Dentre as terap?uticas, a pulpotomia ? apontada na literatura como uma op??o r?pida, de f?cil execu??o, acess?vel e com alto potencial de sucesso, quando corretamente indicadas. Entretanto, a inexist?ncia de m?todos de diagn?stico pulpar fidedignos para sua indica??o e par?metros cl?nicos contundentes para sua proserva??o, a tornam, diante destas incertezas, uma t?cnica pouco utilizada e implementada como tratamento definitivo na endodontia. Fazendo uma reflex?o hist?rica, percebe-se grandes avan?os cient?ficos nos materiais desenvolvidos para os tratamentos conservadores. Por?m, os fatores que atuam diretamente no sucesso ou insucesso e na longevidade da pulpotomia, ainda s?o obscuros ao nosso conhecimento. Diante disso, o objetivo deste estudo foi de tentar esclarecer e compreender este impasse, a partir de um trabalho retrospectivo. Inicialmente, o primeiro artigo desta tese foi selecionado por um caso cl?nico de dens invaginatus tipo 3 com ?pice radicular ainda aberto. Foi adotada uma conduta conservadora em um dos elementos dent?rios e uma abordagem cl?ssica de endodontia para necrose pulpar no outro. O dens invaginatus ? uma anomalia do est?gio de forma??o dent?rio, que promove muitas altera??es estruturais no ?rg?o dental, oferecendo grandes dificuldades quando o tratamento endod?ntico convencional ? solicitado. Em decorr?ncia disto, foi executado o tratamento endod?ntico com trocas de hidr?xido de c?lcio no dente principal e a pulpotomia no dente invaginado, induzindo a sua apicog?nese. Ap?s 21 anos de acompanhamento cl?nico e radiogr?fico, observamos a cura da les?o e a completa forma??o radicular. A preserva??o da vitalidade pulpar, seguida da forma??o da ponte de dentina no dente pulpotomizado, mostrou ser uma alternativa vi?vel e definitiva de tratamento. No segundo artigo da tese, buscamos uma an?lise retorspectiva de desfecho. Reavaliamos 273 pulpotomias em dentes permanentes executadas por um ?nico profissio-nal, especialista em endodontia, e verificamos a influ?ncia de fatores cl?nicos, radiogr?ficos e sist?micos na proserva??o e determina??o de sucesso ou insucesso na pulpotomia. Os dados foram analisados pelo Teste de Regress?o de Cox e Teste Exato de Fisher (p=0,05) por um per?odo que variou de 1 ? 29 anos de proserva??o. Podemos concluir que a pulpoto-mia pode ser executada em qualquer faixa et?ria, sem ter correla??o estat?stica com os problemas sist?micos. A aus?ncia de sintomas cl?nicos e altera??es radiogr?ficas dos tecidos peri-implantares, seguida da presen?a da ponte de dentina e selamento coron?rio herm?tico, s?o indicativos confi?veis na proserva??o.
46

Avalia??o da manuten??o ?ssea em implantes instalados a partir da abordagem trimodal : acompanhamento de 1-4 anos

Sczepanik, F?bio S? Carneiro 31 March 2015 (has links)
Submitted by Setor de Tratamento da Informa??o - BC/PUCRS (tede2@pucrs.br) on 2015-05-28T12:11:24Z No. of bitstreams: 1 469538 - Texto Completo.pdf: 1770446 bytes, checksum: 90b8e8696e775e37ea2dd8f6aec011bc (MD5) / Made available in DSpace on 2015-05-28T12:11:24Z (GMT). No. of bitstreams: 1 469538 - Texto Completo.pdf: 1770446 bytes, checksum: 90b8e8696e775e37ea2dd8f6aec011bc (MD5) Previous issue date: 2015-03-31 / Purpose: The purpose of this retrospective investigation was to evaluate, radiographically and clinically, a group of patients treated with immediate single-tooth placement, immediate restoration implants with a customized definitive abutment with a flapless approach in the area between both maxillary canines. Marginal bone level (MBL) and marginal bone level of neighboring teeth (MBLN) were assessed. Methods: A sample of 20 subjects received 20 tapered platform-switching implants using a minimally invasive surgery (trimodal approach). The mean age was 55.2 years (range 25 - 71 years), and the mean follow-up period was 2.2 years (range 12 - 48 months). Results: The overall treatment survival was 100%. There was no statistically significant difference between MBLN in both mesial and distal aspects, comparing baseline to final follow-up and between the four radiographs independently (i.e., at baseline, at 06 months, at 12 months, and at final follow-up). There was a statistically significant difference between MBL in both mesial and distal aspects at baseline and at final follow-up (p<0.05). Conclusion: Within the limitations of this study, it has demonstrated that the trimodal approach might offer an advantage in terms of marginal bone levels, especially in MBLN, in a mean follow-up time of 26 months. Additionally, reduced overall treatment time, one surgical intervention, and immediate esthetics can be obtained with 100% survival and success rates using a minimally invasive approach. / Objetivos: O objetivo desta investiga??o retrospectiva foi avaliar, radiograficamente e clinicamente, um grupo de pacientes tratados com instala??o imediata de implantes unit?rios, provis?rio imediato com um pilar prot?tico personalizado, com uma abordagem sem descolamento de retalho mucoperiostal na regi?o ?ntero superior. N?vel da crista ?ssea marginal e crista ?ssea marginal a n?vel dos dentes adjacentes foram avaliados. Materiais e m?todos: Uma amostra de 20 indiv?duos recebeu 20 implantes c?nicos com mudan?a de plataforma atrav?s de uma abordagem minimamente invasiva (abordagem trimodal). A m?dia de idade foi de 55,2 anos (variando de 25 a 71 anos) e o per?odo m?dio de acompanhamento foi de 2,2 anos (variando de 12 a 48 meses). Resultados: A taxa total de sobreviv?ncia dos implantes e coroas definitivas foi de 100%. N?o houve diferen?a estatisticamente significativa entre MBLN nas faces mesial e distal, comparando-se baseline ao controle final, assim como n?o houve entre as quatro radiografias independentemente (i.e. baseline, 6 meses, 12 meses e controle final). Houve diferen?a estatisticamente significativa entre MBL nas faces mesial e distal entre baseline e o controle final (p<0,05). Conclus?o: Dentro das limita??es deste estudo, demonstramos que a abordagem trimodal pode oferecer uma vantagem em termos de n?veis de crista ?ssea marginal, especialmente em MBLN, durante um per?odo m?dio de acompanhamento de 26 meses. Adicionalmente, reduzido tempo total de tratamento, apenas uma etapa cir?rgica e est?tica imediata podem ser obtidos com 100% de taxas de sobreviv?ncia e sucesso, utilizando uma abordagem minimamente invasiva.
47

Efeito da terapia cir?rgica anti-infecciosa sobre biomarcadores imunol?gicos em pacientes portadores de peri-implantite

Zani, Sabrina Rebollo 23 January 2015 (has links)
Submitted by Setor de Tratamento da Informa??o - BC/PUCRS (tede2@pucrs.br) on 2015-06-15T19:58:48Z No. of bitstreams: 1 470529 - Texto Completo.pdf: 1858726 bytes, checksum: 5770182d321cd5a1e49c65dc3d839f41 (MD5) / Made available in DSpace on 2015-06-15T19:58:49Z (GMT). No. of bitstreams: 1 470529 - Texto Completo.pdf: 1858726 bytes, checksum: 5770182d321cd5a1e49c65dc3d839f41 (MD5) Previous issue date: 2015-01-23 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior - CAPES / The objective of the present study was to evaluate the effects of an antiinfective surgical therapy over 20 peri-implant crevicular fluid biomarkers in patients with peri-implantitis and to compare these immunologic profiles with the clinical parameters. Fifty-two patients presenting implants affected by peri-implantitis were classified into 4 groups according with probing depth and the presence of bleeding and/or suppuration at mesio-buccal site of each implant with periimplantitis. Clinical parameters were measured and PICF samples were collected from the mesio-buccal site of every implant. All subjects were submitted to anti-infective surgical therapy. Clinical parameters and PICF biomarkers were re-measured at 6 and 12 months after treatment. PICF samples were analyzed using multiplex bead immunoassay for 20 biomarkers. Differences over time were analyzed using generalized estimating equations. The significance level established for all analyses was 5% (p <0.05). The results demonstrated a significant reduction of the clinical parameters post-therapy. However, it was observed a significant increase of some pro-inflammatory biomarkers levels (IL-1?, IL-6, IL-12p40, IL-12p70, IL-17a e sCD-40L). And IL-13 was the only anti-inflammatory cytokine, which had a significant increase in its levels after anti-infective surgical therapy. / O presente estudo tem por objetivo avaliar o efeito da terapia cir?rgica anti-infecciosa sobre 20 biomarcadores imunol?gicos em pacientes com periimplantite, e comparar esse perfil imunol?gico com os par?metros cl?nicos. Foram selecionados 52 pacientes que apresentavam implantes com peri-implantite, os quais foram divididos em 4 grupos de acordo com a profundidade de sondagem e presen?a de sangramento e/ou supura??o no s?tio m?sio-vestibular de cada implante com peri-implantite. Os par?metros cl?nicos foram mensurados e amostras de fluido crevicular peri-implantar, coletadas do s?tio m?sio-vestibular de cada implante. Todos pacientes foram submetidos ? terapia cir?rgica anti-infecciosa e reavaliados 6 e 12 meses ap?s o tratamento. As amostras de fluido crevicular foram analisadas atrav?s do ensaio imunol?gico Luminex (multi-an?lise com micro-esferas) para detec??o de 20 biomarcadores. Diferen?as entre os grupos em rela??o aos n?veis desses biomarcadores ao longo do tempo foram analisadas estatisticamente atrav?s das equa??es de estima??o generalizadas. O n?vel de signific?ncia estabelecido foi de 5% (p < 0,05). Os resultados demonstraram redu??es significativas dos par?metros cl?nicos, entretanto mostraram aumentos significativos dos n?veis de alguns biomarcadores pr?-inflamat?rios (IL-1?, IL-6, IL-12p40, IL-12p70, IL-17a e sCD-40L) ap?s a terapia cir?rgica. A IL-13 foi a ?nica citocina anti-inflamat?ria que mostrou aumento significativo ap?s o tratamento.
48

Avalia??o in vitro de matrizes de PLGA com horm?nio do crescimento recombinante humano : an?lise estrutural e din?mica de libera??o do horm?nio

Oliveira, Henrique do Couto de 31 March 2015 (has links)
Submitted by Setor de Tratamento da Informa??o - BC/PUCRS (tede2@pucrs.br) on 2015-06-24T12:10:10Z No. of bitstreams: 1 471057 - Texto Completo.pdf: 1136786 bytes, checksum: 1d97578e696595fa93bee351f70a6852 (MD5) / Made available in DSpace on 2015-06-24T12:10:10Z (GMT). No. of bitstreams: 1 471057 - Texto Completo.pdf: 1136786 bytes, checksum: 1d97578e696595fa93bee351f70a6852 (MD5) Previous issue date: 2015-03-31 / Growth factors such as the recombinant human growth hormone are drawing attention on the field of bone reconstruction. However, due to the protein?s short half-life, biodegradable polymers, like PLGA, have been applied seeking a slower and controlled drug release for topical applications. Objective: To asses, in vitro, the behavior of PLGA matrices with 2 different rhGH concentrations. Materials and Methods: Three groups of triplicate samples were created: group I with pure PLGA (control), group II with PLGA loaded with a higher rhGH concentration and group III with PLGA loaded with a lower concentration of the hormone. Each group was analyzed macro and microscopically (SEM) and, by means of the hidrolitic degradation test, the dynamics of release of rhGH as well as the alterations on the pH of the incubation medium were evaluated, throughout 29 days. Results: Matrices from all groups showed indistinguishable macro and microscopic features. Group II released a higher quantity of rhGH, as expected, however there was no clear release pattern on both groups. rhGH release was observed until the 22? day and there was no statistically significant difference on weight loss between the 3 groups. pH values found were clinically viable. Conclusion: Morphological properties of the matrices must be assessed according to its applications and target-tissue to be substituted/regenerated and it was not possible to determine a pattern of rhGH distribution within PLGA matrices on this survey. The matrices can be used as rhGH carriers and were able to extend hormone release for a period of 22 days. Wheight loss showed equal patterns (statistically), despite the addition of rhGH to the polymer. The pH values were clinically viable and the reduction of rhGH concentrations on future researches should not be carried out using this methodology, possibly owing to limitations on screening with ultra-violet spectroscopy. / Fatores de crescimento como o horm?nio do crescimento humano recombinante v?m ganhando aten??o no campo da reconstru??o ?ssea. No entanto, devido ? sua meia-vida curta, pol?meros biodegrad?veis, como o PLGA, v?m sendo utilizados visando libera??o mais lenta e controlada deste horm?nio quando de sua aplica??o t?pica. Objetivo: Avaliar, in vitro, o comportamento de matrizes de PLGA com 2 concentra??es diferentes de rhGH. Materiais e M?todos: Tr?s grupos de amostras em triplicatas foram montados: grupo I com PLGA puro (controle); grupo II com PLGA associado ao rhGH em maior concentra??o e; grupo III com PLGA associado ao rhGH em menor concentra??o. Cada grupo foi analisado macroscopicamente e microscopicamente (MEV) e, por meio de teste de degrada??o hidrol?tica, avaliou-se a din?mica de libera??o do rhGH assim como as altera??es de pH no meio de incuba??o ao longo de 29 dias. Resultados: As matrizes dos 3 grupos de estudo ficaram com caracter?sticas morfol?gicas indistingu?veis macro e microscopicamente. O grupo II liberou maior quantidade de rhGH que o grupo III, como era o esperado, no entanto, n?o houve um padr?o claro de libera??o em ambos os grupos. A libera??o de rhGH foi observada at? o 22? dia de avalia??o e n?o houve diferen?a estat?stica na perda de massas entre os grupos. Os valores de pH encontrados foram compat?veis com a aplica??o cl?nica. Conclus?o: As propriedades morfol?gicas devem ser avaliadas conforme a aplica??o do material e do tecido alvo a ser regenerado/substitu?do e n?o foi poss?vel estabelecer um padr?o de distribui??o do rhGH nas matrizes de PLGA neste estudo. As matrizes podem ser utilizadas como carreadoras de rhGH tendo sido capazes de prolongar a libera??o do horm?nio por um per?odo de 22 dias. A perda de massas se manteve igual (estatisticamente), a despeito da adi??o do rhGH ao pol?mero. O pH das amostras se mostrou favor?vel ? aplica??o cl?nica das matrizes e a redu??o nas concentra??es de rhGH para estudos futuros n?o deve ser avaliada por esta metodologia, visto que podem se tornar de dif?cil leitura pelo EAU-Vis.
49

Efeitos citot?xicos e genot?xicos das ligas de solda de prata em ortodontia : revis?o sistem?tica

Garcia, Renato Dalla Porta 17 June 2015 (has links)
Submitted by Setor de Tratamento da Informa??o - BC/PUCRS (tede2@pucrs.br) on 2015-09-04T19:23:58Z No. of bitstreams: 1 474609 - Texto Completo.pdf: 859580 bytes, checksum: cb3a065e3f91d18ed57ee2c9c80a2a6f (MD5) / Made available in DSpace on 2015-09-04T19:23:58Z (GMT). No. of bitstreams: 1 474609 - Texto Completo.pdf: 859580 bytes, checksum: cb3a065e3f91d18ed57ee2c9c80a2a6f (MD5) Previous issue date: 2015-06-17 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior - CAPES / A systematic review was performed on the cytotoxic and genotoxic effects of silver solder alloys in orthodontics. The search was conducted through medical databases, PubMed, EMBASE, Web of Science and Cochrane Library. The search of gray literature included the annals of the meetings of the Brazilian Society for Dental Research (SBPqO) and of the American Association of Orthodontists (AAO). The articles found were submitted to selection criteria and eligibility by two independent blind researchers. Afterwards, a manual search was conducted on articles?s references and study data were extracted by standardized forms. Sixty-four out of 76 articles were excluded because they did not reach the eligibility criteria. The remaining 12 articles and 3 other raised from manual search were included in this study. Two articles found on gray literature were repeated, though excluded. The level of agreement between researchers was adequate in the selection criteria (kappa = 0.916) and very precise for the eligibility (kappa = 1). As a conclusion of the systematic review, the silver solder alloy may cause cytotoxic, mutagenic and genotoxic effects when applied on orthodontic treatment. / Foi realizada uma revis?o sistem?tica dos efeitos citot?xicos e genot?xicos das ligas de solda de prata em Ortodontia. Para tanto, foi efetuada uma busca sistem?tica nas bases de dados PubMed, EMBASE, Web of Science e Biblioteca Cochrane. Foi pesquisado na literatura cinza os anais da Sociedade Brasileira de Pesquisa Odontol?gica (SBPqO) e os encontros anuais da American Association of Orthodontists (AAO). Os artigos encontrados foram submetidos a um crit?rio de sele??o e elegibilidade por dois pesquisadores de maneira cega e independente. Ap?s a sele??o dos estudos, uma busca manual foi realizada nas refer?ncias destes e foram extra?dos os dados dos estudos atrav?s de fichas padronizadas. Foram encontrados no total 76 artigos. Destes, 64 foram exclu?dos, pois n?o preencheram os crit?rios de elegibilidade. Os 12 estudos remanescentes foram selecionados para o presente trabalho. Al?m disso, outros tr?s artigos foram inclu?dos atrav?s da busca manual. Dois artigos encontrados na literatura cinza foram exclu?dos, pois eram repetidos. O n?vel de concord?ncia entre os pesquisadores na sele??o dos estudos foi considerado adequado (kappa=0,916) e para a elegibilidade dos estudos foi muito preciso (kappa=1). Ap?s avalia??o dos dados extra?dos concluiu-se que ligas de solda de prata podem provocar efeitos citot?xicos, genot?xicos e mutag?nicos.
50

Efeitos da solu??o de Carnoy no reparo ?sseo em cavidades experimentais de t?bias de ratos

Takahashi, Andr? 16 December 2008 (has links)
Made available in DSpace on 2015-04-14T13:29:22Z (GMT). No. of bitstreams: 1 409050.pdf: 4761695 bytes, checksum: 304fc514158de2cbb7ba0115144a77a3 (MD5) Previous issue date: 2008-12-16 / [...] Essa tese apresenta tr?s artigos: o primeiro relacionado a estrat?gias no planejamento e na condu??o de estudos n?o aleat?rios na Cirurgia e Traumatologia Bucomaxilofacial (CTBMF), esse artigo faz considera??es sobre o tipo de pesquisa cl?nica adotada peculiarmente na ?rea de CTBMF, considerando as dificuldades e limita??es de se realizar estudos cl?nicos baseados em fortes evid?ncias cient?ficas nessa ?rea; o segundo; uma revis?o de literatura sobre o ameloblastoma enfocando os aspectos histopatol?gicos e as implica??es cl?nicas na indica??o dos tratamentos; e o terceiro ? um estudo experimental em t?bias de ratos que avalia o reparo ?sseo em cavidades submetidas ao contato com solu??o de Carnoy. O primeiro estudo avalia os poss?veis desenhos e estrat?gias para se conduzir um estudo cl?nico. No caso de tratamento de ameloblastomas o melhor desenho que 10 proporcionar? uma evidencia cient?fica v?lida s?o s?ries-de-casos prospectivos e ou estudos coorte. O segundo artigo faz uma revis?o da literatura sobre os tipos anatomopatol?gicos de ameloblastomas com o objetivo de determinar uma rela??o entre as caracter?sticas histol?gicas e o comportamento biol?gico do tumor. E finalmente, no terceiro artigo, a solu??o de Carnoy ? testada experimentalmente em cavidades ?sseas e as altera??es no reparo ?sseo s?o avaliadas, essa solu??o tem sido utilizada para diminuir a taxa de recidiva do ameloblastoma unic?stico, ap?s a enuclea??o do tumor [...]

Page generated in 0.0679 seconds