• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 864
  • 216
  • 24
  • 18
  • 17
  • 17
  • 15
  • 14
  • 10
  • 10
  • 3
  • 3
  • 3
  • 2
  • 2
  • Tagged with
  • 1151
  • 419
  • 277
  • 170
  • 143
  • 139
  • 107
  • 98
  • 82
  • 82
  • 81
  • 77
  • 75
  • 72
  • 72
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
951

Percepção sonora e térmica e avaliação de conforto em espaços urbanos abertos do município de Belo Horizonte - MG, Brasil / Sound and thermal perception and evaluation of comfort in open urban spaces in the city of Belo Horizonte - MG, Brazil

Simone Queiróz da Silveira Hirashima 17 December 2014 (has links)
Em espaços urbanos abertos, particularmente nas grandes cidades de climas tropicais, os pedestres estão expostos não somente a níveis sonoros elevados como também a elevadas cargas térmicas, situação que pode gerar tanto o desconforto acústico quanto o térmico. Entretanto, na maioria das vezes, a relação entre a exposição a condições acústicas e térmicas adversas e a percepção humana dessas condições são estudadas separadamente. Neste trabalho propõe-se, portanto, uma abordagem integrada para a avaliação do conforto acústico e térmico urbano e para o estudo de seus prováveis efeitos combinados. Esta pesquisa foi realizada em Belo Horizonte - MG, Brasil, cidade localizada em região de clima tropical de altitude, com verões quentes e úmidos e invernos frios e secos. Utilizou-se o método indutivo experimental na condução dos trabalhos. Dados acústicos e climáticos foram medidos simultaneamente à aplicação de formulários em dois dias representativos do verão (março/2013) e do inverno (agosto/2013), e em duas praças contrastantes em relação ao seu ambiente acústico e térmico bem como aos seus parâmetros morfológicos como o fator de visão do céu, o altura dos edifícios, o tipo de pavimento, a presença de fontes de água e vegetação. Os índices Nível de Pressão Sonora Equivalente Contínuo, ponderado na curva A (LAeq) e Temperatura Equivalente Fisiológica (PET) foram usados para representar, respectivamente, as condições acústicas e microclimáticas. Foram coletados por meio dos formulários variáveis subjetivas (percepção do volume do ambiente sonoro, avaliação de incômodo relacionado ao ambiente sonoro, avaliação de conforto acústico, percepção de sensações térmicas, preferência de sensações térmicas e avaliação de conforto térmico), variáveis individuais (vestimenta, atividade física, idade, peso, altura, sexo) e dadoscontrole, relacionados aos aspectos psicológicos, sociais e culturais que podem interferir na percepção acústica e térmica do ambiente. A amostra compreendeu aproximadamente 1.700 entrevistados. O tratamento estatístico dos dados coletados abarcou análise descritiva, correlações e regressões. Modelos de regressão logística ordinal foram utilizados para predizer as faixas de percepção acústica e térmica; e modelos de regressão logística, para predizer as faixas de conforto e desconforto acústico e térmico. Os resultados do estudo incluem, dentre outros: 1) a calibração do índice LAeq para percepção do volume sonoro - faixas: \"Baixo\", <35dB(A), \"Normal\", de 36 a 67dB(A), e \"Alto\", >68dB(A); e para avaliação de conforto acústico - faixas: \"Confortável\", <67dB(A), e \"Desconfortável\", >68dB(A); 2) a calibração do índice PET para percepção de sensações térmicas - faixas: \"Frio\", <18,9°C, \"Bem\", de 19 a 27°C, e \"Calor\", >27,1; e para avaliação de conforto térmico - faixas: \"Confortável\", de 23 a 31°C, e \"Desconfortável\", <22,9 e >31,1°C; 3) a definição das temperaturas neutra e preferida para verão (27,7 e 14,9°C) e inverno (15,9°C e 20,9°C), respectivamente, demonstrando a influência da expectativa na avaliação das condições térmicas; e 4) a comprovação de que o aumento do desconforto acústico pode acarretar (ainda que em pequena escala) o aumento do desconforto térmico e vice-versa. Estes resultados podem nortear o esclarecimento de questões referentes à percepção e ao conforto acústico e térmico em espaços urbanos, orientando as políticas públicas em projetos urbanísticos relacionados a esses temas. / In urban open public spaces, particularly in big cities of tropical climate, city-users are often exposed not only to high sound levels but also to high thermal loads, a situation that can cause both acoustic and thermal discomfort. Nevertheless, in most cases, the relationship between the exposure to each of these adverse conditions and human perceptions towards each of them are studied separately. In order to address the lack of a combined analysis of these conditions, this research has adopted an integrated approach to evaluate urban acoustic and thermal comfort and their likely combined effects. This study was carried out in in the Brazilian city of Belo Horizonte, in the state of Minas Gerais, a city located in a region of tropical of altitude climate, with hot wet summers and cold dry winters. Acoustic and climatic data were measured simultaneously with the administration of questionnaires in two representative days of summer (March/2013) and winter (August/2013), in two squares that noticeably differ in relation to their acoustic and thermal environment and their morphological parameters such as the sky view factor, the height of the buildings, the type of pavement, the presence of water sources and the vegetation. The LAeq,T and the PET index were used to represent acoustic and microclimatic conditions respectively. Subjective variables (perceived volume of the environmental sound, assessment of annoyance caused by environmental sound, acoustic comfort evaluation, perception of thermal sensation, thermal sensation preference and evaluation of thermal comfort), personal variables (clothing, physical activity, age, weight, height, gender) and control data related to psychological, social and cultural issues that might interfere with acoustic and thermal perception of the environment were collected through the questionnaires. The sample consisted of approximately 1,700 respondents. The statistical treatment of the data collected was comprised of descriptive analysis as well as analysis using correlations and regressions. Ordinal logistic regression models were used to predict the ranges of acoustic and thermal perception and logistic regression models were used to predict the ranges of acoustic and thermal comfort and discomfort. Some of the results of this study are: 1) the calibration of the LAeq index for perceived loudness - ranges: \"Low\", <35dB(A), \"Normal\", between 36 and 67dB(A), and \"High\", >68dB(A); and for evaluation of acoustic comfort - ranges: \"Comfortable\" <67dB(A), and \"Uncomfortable\", >68dB(A); 2) the calibration of the PET index for perceived thermal sensations - ranges, \"Cold\", <18.9°C, \"Well\", 19-27°C, and \"Hot\", >27.1°C; and for evaluation of thermal comfort - ranges: \"Comfortable\", 23-31°C, and \"Uncomfortable\", <22.9 and >31.1°C; 3) the definition of neutral and preferred temperatures for Summer (27.7 and 14.9°C) and Winter (15.9°C and 20.9°C), respectively, showing the influence of expectation on evaluation of thermal conditions; and 4) the confirmation that an increase of the acoustic discomfort may cause (albeit on a small scale) an increase in the thermal discomfort and vice versa. These results might shed light on the issues of acoustic and thermal perception and comfort in urban spaces, helping to guide public policies on urban projects related to these topics.
952

Produção de cana-de-açúcar nas condições climáticas Af

MIRANDA, Augusto Sousa 28 March 2014 (has links)
Submitted by Cássio da Cruz Nogueira (cassionogueirakk@gmail.com) on 2017-05-15T11:35:18Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_ProducaoCanaAcucar.pdf: 641264 bytes, checksum: d9c2b301cea2f9a556790497539ec63e (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-05-16T18:13:39Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_ProducaoCanaAcucar.pdf: 641264 bytes, checksum: d9c2b301cea2f9a556790497539ec63e (MD5) / Made available in DSpace on 2017-05-16T18:13:39Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_ProducaoCanaAcucar.pdf: 641264 bytes, checksum: d9c2b301cea2f9a556790497539ec63e (MD5) Previous issue date: 2014-03-28 / A cultura da cana-de-açúcar desempenha importante papel socioeconômico no Brasil, apresentando como principais produtos o açúcar e álcool, além de ser utilizada como fonte de alimento volumoso nos sistemas de produção animal. Objetivou-se avaliar a cultura de cana-de-açúcar cultivada em condições climáticas tipo Af, caracterizado por precipitação pluviométrica em todos os meses do ano e ausência de estação seca. Foram determinados a composição químico bromatológica, características agronômicas e tecnológicas de três cultivares de cana-de-açúcar: IACSP93-6006, RB83-5486 e SP79-1011. Experimento foi realizado em delineamento em blocos casualizados, com três tratamentos e quatro repetições, sendo as médias comparadas pelo teste de Tukey ao nível de 5% de probabilidade. Houve diferença (P˂0,05) para matéria seca, extrato etéreo, proteína bruta, fibra em detergente ácido, lignina, celulose, fibra em detergente neutro corrigida para cinzas e proteína, carboidratos totais, fração B2, fração C e produção de matéria seca. Os componentes da porção fibrosa (FDNcp, LIG, fração C) apresentaram valores baixos, resultando em maior valor dos carboidratos não fibrosos, o que é interessante do ponto de vista da alimentação de bovinos, haja vista, que os componentes da porção fibrosa influenciam no consumo e digestibilidade do alimento. As cultivares apresentaram produção de matéria seca elevadas com destaque para as cultivares IACSP93-6006 e SP79-1011. Quanto às características agronômicas houve diferença (P˂0,05) para a produção de matéria natural, número de colmos, comprimento do colmo e diâmetro do colmo, com destaque para as cultivares IACSP93-6006 e SP79-1011, demonstrando adaptação às condições edafoclimáticas da região. Não houve diferença (P>0,05) para os atributos tecnológicos, Pol, °Brix, açúcares redutores, pureza, açúcares redutores totais, fibra e umidade, cujos valores foram baixos devido ao regime pluviométrico da região, pois a cana-de-açúcar necessita de estresse térmico ou hídrico para que ocorra a maturação. Nas condições do clima Af não há estação seca sendo que o mês menos chuvoso no período experimental apresentou 106,6 mm e a temperatura média de 26,8°C. / The culture of cane sugar plays an important socioeconomic role in Brazil, with main products as sugar and alcohol, as well as being used as a source of roughage in food animal production systems. This study aimed to evaluate the behavior of the culture of cane of sugar grown in Af type weather, characterized by rainfall in all months of the year and no dry season weather conditions. IACSP93-6006, RB83-5486 and SP79-1011: The bromatological chemical composition, agronomic and technological characteristics of three cultivars of cane sugar were determined. Experiment was conducted in a randomized block design with three treatments and four replicates and the averages compared by Tukey test at 5% probability. There were differences (P˂0.05) for dry matter, ether extract, crude protein, acid detergent fiber, lignin, cellulose, neutral detergent fiber corrected for ash and protein, total carbohydrates, B2 fraction, fraction C and raw dry’s production. The components of the fibrous portion (NDF, LIG, fraction C) showed low values, resulting in higher value of non- fiber carbohydrates, which are interesting from the point of view of the cattle feeding, given that the components of the fibrous portion influence the intake and digestibility of the food. The cultivars showed higher dry matter production highlighting the IACSP93-6006 and SP79-1011 cultivars. For agronomic characteristics were no differences (P˂0.05) for the production of natural material, number of culms, culm length and culm diameter, highlighting the IACSP93-6006 and SP79-1011 cultivars, demonstrating adaptation to climatic conditions the region. There was no difference (P>0.05) for technological attributes, Pol, Brix, reducing sugars, purity, total reducing sugars, fiber and moisture, whose values were low due to rainfall in the region, because the cane sugar requires heat or water stress for maturation to occur. In weather conditions Af has no dry season being the least rainy month trial period had 106.6 mm and the average annual temperature was 26.8 ° C.
953

Produção e características estruturais de capim-Tanzânia sob diferentes frequências de desfolhações em clima tropical Am

MACEDO, Vitor Hugo Maués 09 December 2016 (has links)
Submitted by Cássio da Cruz Nogueira (cassionogueirakk@gmail.com) on 2017-05-15T18:00:59Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_ProducaoCaracteristicasEstruturais.PDF: 1348178 bytes, checksum: 766770e25005390e9402df1d9830c70b (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-05-22T15:15:39Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_ProducaoCaracteristicasEstruturais.PDF: 1348178 bytes, checksum: 766770e25005390e9402df1d9830c70b (MD5) / Made available in DSpace on 2017-05-22T15:15:39Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_ProducaoCaracteristicasEstruturais.PDF: 1348178 bytes, checksum: 766770e25005390e9402df1d9830c70b (MD5) Previous issue date: 2016-12-09 / Objetivou-se com o presente trabalho determinar o efeito de diferentes frequências de desfolhações (FD) de Panicum maximum cv. Tanzânia durante as estações climáticas (EC) chuvosa (ECH) e seca (ES) de 2015, na região amazônica, em clima tropical Am, sobre as características estruturais e de produção do capim. O delineamento utilizado foi em blocos casualizados com seis tratamentos correspondente as FD baseadas em seis intervalos fixos entre desfolhações: 14; 21; 28; 35; 42 e 49 dias, com cinco repetições, dispostas na forma de parcelas de 12 m2 a campo em esquema de parcelas subdivididas no tempo. Foram avaliados os padrões demográficos de perfilhamento (PDP), a densidade populacional de perfilhos (DPP), altura do dossel (AL), índice de área foliar (IAF), interceptação luminosa (IL), acúmulo total (ACT) de biomassa, e suas proporções em folha (PF), haste (PA) e material morto (PMM). A média das variáveis dos tratamentos dentro de cada EC foi submetida a análise de variância e o desdobramento da interação entre as diferentes FD e a EC (FD × EC) foram efetuados quando significativos pelo teste F. As médias foram analisadas por contrastes polinomiais ortogonais utilizando o procedimento PROC MIXED do software SAS. A DPP, AL, IL, IAF e ACT tiveram interação (P < 0,05) entre as FD e as EC. A DPP diminuiu linearmente (P < 0,0001) de 891 para 560 perfilhos/m² na ECH, e de 533 para 369 perfilhos/m² na ES, da FD de 14 para a de 49 dias, respectivamente. A AL apresentou ajuste linear (P < 0,0001) caracterizado pelo aumento do seu valor com a diminuição das FD. O aumento da AL variou de 58,72 a 117,42 cm com a redução da FD durante a ECH. Devido a menor disponibilidade hídrica na ES, a AL teve uma pequena variação de 37,69 para 49,03 cm, caracterizada por um ajuste quadrático (P = 0,0002). Tanto o IAF quanto a IL, na ECH, apresentaram efeito quadrático (P < 0,05) com aumento de 3,60 para 6,05 e de 90,85% para 98,30% nas FD de 14 a 49 dias, respectivamente. O ACT, que representa a soma dos ciclos dentro de cada EC apresentou ajuste quadrático (P = 0,0028) na ECH com maiores valores para as FD de 14 e 21 dias, e ajuste quadrático (P < 0,0001) na ES. Na estação chuvosa recomenda-se frequências de desfolhações por volta de 21 dias, correspondente à interceptação de luz de 95% e altura média do dossel em 71 cm. Na estação seca, recomenda-se menores frequências de desfolhações como a cada 49 dias, devido ao alto acúmulo de forragem em relação as outras frequências no período seco. / This study determined the effect of different frequency of defoliation (FD) on the structural and production characteristics of Panicum maximum cv. Tanzania during the rainy season (RS) and dry season (DS) of 2015, in the Amazon region of Brazil. A randomized block design with six treatments and five replicates was used. The treatments corresponded to six FD (14; 21; 28; 35; 42 and 49 days). arranged in plots of 12 m2. Were evaluated the demographic pattern of tillering (DPT), tiller population density (TPD), canopy height (CH), leaf area index (LAI), , light interception (LI), total forage accumulation (TFA), and the leaf (LP), stem (SP) and dead material (DMP) proportions. The mean of the variables in each season was subjected to analysis of variance and the unfolding of the interaction between the different FD and the seasons were performed when significant by the F test. The means were analyzed by orthogonal polynomial contrasts using the PROC MIXED procedure of SAS software. Significant interaction (P<0.05) between FD and seasons was observed to the TPD, CH, LI, LAI and TFA variables. The TPD decreased (P < 0.0001) linearly from 891 to 560 tillers/m2 in the RS, and from 533 to 369 tillers/m2 in DS with FD from 14 to 49 days, respectively. Linear response was observed to the CH (P < 0.0001) characterized by the increase of its value with the decreasing of FD. The CH ranged from 58.72 to 117.42 cm with decreasing FD in the RS. In the DS the CH varied less than in the RS wit values between 37.69 and 49.03 cm, characterized for a quadratic adjustment (P = 0.0002). In the RS, the LAI and LI showed quadratic response (P < 0.05) with increasing from 3.60 to 6.05 and from 90.85% to 98.30% in FD from 14 to 49 days, respectively. The TFA which represents the sum of the cycles within each season, showed a quadratic adjustment (P = 0.0028) in RS with higher values for FD of 14 and 21 days, and a quadratic adjustment (P < 0.0001) in DS. In the rainy season it is recommended defoliation frequency around 21 days, corresponding to the 95% light interception and the canopy average height at 71 cm. In the dry season lower frequencies of defoliation are recommended such as every 49 days, due to high forage accumulation in relation to other frequencies in the dry season.
954

Impacto da morfologia no desempenho térmico das parcelas urbanas em clima equatorial na cidade de Belém

PINHEIRO, Dorival Freitas 11 April 2013 (has links)
Submitted by Cássio da Cruz Nogueira (cassionogueirakk@gmail.com) on 2017-05-26T11:26:47Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_ImpactoMorfologiaDesempenho.pdf: 6847855 bytes, checksum: 5b8cad37e4eb573f9fafd352ee64975f (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-06-02T13:32:04Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_ImpactoMorfologiaDesempenho.pdf: 6847855 bytes, checksum: 5b8cad37e4eb573f9fafd352ee64975f (MD5) / Made available in DSpace on 2017-06-02T13:32:04Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_ImpactoMorfologiaDesempenho.pdf: 6847855 bytes, checksum: 5b8cad37e4eb573f9fafd352ee64975f (MD5) Previous issue date: 2013-04-11 / O objetivo deste estudo é analisar o impacto gerado pelo contexto morfológico de parcelas urbanas, segundo suas características próprias a partir das variáveis presentes no microclima urbano inerentes aos Bairros da Cidade Velha e Umarizal em Belém. Demonstrar, a partir do padrão metodológico desenvolvido, uma aproximação dos efeitos das trocas térmicas dentro das parcelas urbanas com suas diferentes tipologias encontradas, o que permitirá, além do entendimento mais aproximado dos fenômenos resultantes da interação climática com as tipologias específicas, evidenciar estratégias urbanísticas mais apropriadas ao desempenho térmico. Para demonstrar os efeitos destes parâmetros urbanísticos e sua influência na qualidade do microclima foram utilizados como estratégias de aquisição de dados, captação de imagens IFR (infravermelho) de superfícies, fotos com lente angular olho de peixe, registro de temperaturas de globo, bulbo seco e úmido, sol ar, levantamento de campo das edificações, somadas às técnicas de análise do balanço energético Fator de Visão de Céu, Massa Construída e Recorte de Carga Térmica. O Bairro da Cidade Velha está inserido na origem da formação urbana da cidade e, dentro do seu contexto morfológico, possui características volumétricas que, ao seu tempo, foram apontadas como soluções de adaptação ao clima, tornando-o propício ao desenvolvimento de estudos térmicos. Já o bairro do Umarizal, que faz parte da área de expansão central da cidade, possui como característica morfológica marcante um processo de crescente verticalização, principalmente na última década, e com isso, vem se constituindo no bairro com maior mudança de perfil construtivo e de adensamento dos últimos anos, o que o define como peça fundamental para esta investigação. Tendo como base alguns estudos já realizados e procurando agregar novos parâmetros de análise e conceitos, definiu-se a utilização de técnicas de análise do balanço energético e das trocas térmicas urbanas capazes de identificar, conceitualmente, a capacidade de acúmulo de carga térmica e indicar caminhos para implementar procedimentos de análise de desempenho térmico de frações urbanas. Critérios metodológicos desenvolvidos a partir da investigação dos efeitos provenientes da relação entre padrões climatológicos locais e padrões urbanísticos de ocupação podem se bem aproveitados, gerar parâmetros urbanísticos de ocupação que viabilizem as cidades não só em suas questões ambientais como na sua eficiência global, apontando soluções aos planejadores e gestores urbanos ao instrumentalizar um registro da capacidade de “carga” destes determinados territórios. / The objective of this study is to analyze the impact generated by models of occupation of urban spaces in installments, according to its own characteristics of the variables present in the urban microclimate inherent Neighborhoods Old Town and Umarizal Demonstrate in Belém, from the standard methodology developed, an approximation of the effects of thermal exchanges within the urban portions with their different typologies found, which will allow, besides understanding more approximate of the resulting phenomena of the climatic interaction with the specific typologies, to evidence more appropriate town planning strategies to thermal performance. To demonstrate the effects of these urban parameters and their influence on the quality of the microclimate, were used as strategies for data acquisition, image capture IFR (IR) surface, angled shots with a fisheye lens, record temperatures globe, dry and humid bulb, sun air, field survey of the buildings, together with the technical analysis of energy balance factor Sky View, Built Mass and Cut Heat Load. The Old Town district is inserted in origin of formation of the town and within its context morphological Volumetric has characteristics that in his time been regarded as solutions to climate adaptation, making it conducive to the development of thermal studies. Already Umarizal neighborhood, which is part of the expansion area of the city center, has a characteristic morphological marked a process of increasing vertical integration, especially in the last decade, and with it, has been constituted in the district with the highest profile change and constructive densification of recent years, which defines it as a key to this investigation. Based on some previous studies and looking to add new analysis parameters and concepts, we defined the use of techniques for analyzing of the energy balance and the thermal exchanges urban able to identify, conceptually, the ability to build thermal load and indicate ways implement procedures for analysis of thermal performance of urban fractions. Methodological criteria developed from the investigation of the effects arising from the relationship between local climatological patterns and urban standards of occupancy can be good use, generate urban parameters that enable the occupation of cities not only in their environmental issues in its overall efficiency, pointing to solutions to planners and urban managers to equip a record of the capacity to "load" these determined territories.
955

Aspectos jurídicos do marco regulatório do pré-sal sob a luz da política nacional sobre mudança do clima. / Legal aspects of regulatory pre-salt in the light of national policy on climate change.

Silva, Ana Claudia Ribeiro Cardoso da 24 April 2014 (has links)
Submitted by Rosina Valeria Lanzellotti Mattiussi Teixeira (rosina.teixeira@unisantos.br) on 2016-04-12T14:32:52Z No. of bitstreams: 1 Ana Claudia Ribeiro Cardoso da Silva.pdf: 2526727 bytes, checksum: 671c8fba2162cafddef2b61b34bbb0a5 (MD5) / Made available in DSpace on 2016-04-12T14:32:54Z (GMT). No. of bitstreams: 1 Ana Claudia Ribeiro Cardoso da Silva.pdf: 2526727 bytes, checksum: 671c8fba2162cafddef2b61b34bbb0a5 (MD5) Previous issue date: 2014-04-24 / The present dissertation had with main objective to analyse the regulatory framework of the pre ¿salt the light of national policy on climate change, identifying whether there are points of confronting between the two legal frameworks. Therefore, it was necessary to demonstrate the evolution of environmental law in the world and in Brazil, as well as the institutionalization of climate protection policy in Brazil, their policies and objectives. In the oil industry sector, evaluate the influence of owning countries and oil producers in the Brazilian energy matrix, the legal changes that have altered the ownership of natural resources throughout history, the change of legislation for oil exploration in the pre -salt field in 2010, and the current scenario of oil exploration in the polygon. In order to achieve the proposed goal, there was a brief overview on the scientific aspects of climate change and the voluntary commitments made by Brazil, in an effort to reduce gas emissions between 36,1 % to 38,9 % by 2020. It was found that oil is a finite resource and that, according to the theory of Peak Oil and the current target for oil exploration in the pre-salt, there are two possible future scenarios with different consequences to Brazil. It was understood that the country published two legislations, one of climate protection and other oil exploration in the pre-salt, which does not establish a dialogue and demonstrate a route of confront between the policies. Still, proposals were searched for confronting of the two scenarios mentioned above. / A presente dissertação teve como objetivo principal analisar o marco regulatório do pré-sal sob a luz da política nacional sobre mudança do clima, identificando se existem pontos de colidência entre os dois marcos legais. Para tanto, foi preciso demonstrar a evolução do direito ambiental do mundo e no Brasil, assim como a institucionalização da política de proteção ao clima no Brasil, suas diretrizes e objetivos. No setor da indústria petrolífera, foi necessário avaliar a influência dos países possuidores e produtores de petróleo na matriz energética brasileira, as mudanças legais que alteraram a propriedade dos recursos naturais ao longo da história, a mudança da legislação do petróleo para a exploração no campo do pré-sal em 2010, e o atual cenário de exploração de petróleo no polígono do pré-sal. De modo a cumprir o objetivo proposto, realizou-se uma breve abordagem sobre os aspectos científicos das mudanças climáticas publicadas pelo IPCC e os compromissos voluntários assumidos pelo Brasil, no sentido de reduzir suas emissões de GEE entre 36,1% a 38,9%, até 2020. Constatou-se que o petróleo é um recurso finito e que, de acordo com a teoria do Peak Oil e a atual meta de exploração de petróleo no pré-sal, existem dois possíveis cenários futuros com consequências distintas paras o Brasil. Entendeu-se que o país editou duas legislações: uma de proteção ao clima e outra de regulamentação da exploração de petróleo no pré-sal, que que não estabelecem um diálogo e demonstram uma rota de confronto entre as políticas. Ainda, buscou-se propostas para o enfrentamento dos dois cenários mencionados acima.
956

Fenóis totais no cafeeiro em razão das fases de frutificação e do clima. / Total phenols in the coffee tree due to the fructification phases and the climate.

Salgado, Paula Rodrigues 14 January 2005 (has links)
Os vegetais apresentam defesa natural contra os fatores externos, bióticos e abióticos, por meio da síntese de compostos fenólicos no metabolismo secundário, as quais variam com as fases fenológicas e com o clima. O aumento dos compostos fenólicos nas plantas está, diretamente, relacionado com a resistência à infecção por patógenos e à infestação de pragas. Entretanto, pouco se sabe sobre a variação dos teores dessa substância durante os estádios fenológicos do cafeeiro, em particular, nas fases de frutificação, e em razão das condições climáticas. Tais conhecimentos são fundamentais para a previsão dos riscos de ataques aos vegetais, uma vez que a defesa natural da planta deve mudar ao longo do ciclo. O experimento foi realizado em uma cultura de Coffea arabica L., cultivar Obatã IAC 1669-20, instalada no campo experimental do Departamento de Produção Vegetal, da Escola Superior de Agricultura "Luiz de Queiroz", Universidade de São Paulo, Piracicaba/SP. Para a realização do experimento foi adotado o delineamento experimental inteiramente casualizado, utilizando quatro tratamentos (plantas com e sem frutos - folhas dreno e plantas com e sem frutos - folhas fonte) e cinco repetições constituídas por plantas individuais. Após a análise de variância dos resultados foi aplicado o teste t de Student ao nível de 5 % de significância para a comparação das médias entre os tratamentos. Os teores de fenóis totais (µg g-1) foram extraídos das folhas maduras (fonte) e novas (dreno) e analisados em relação à produção de café, fenologia e clima. As variáveis climáticas adotadas foram temperatura atmosférica (média, mínima e máxima; oC), radiação global (MJ m-2 dia-1) e insolação diária (h dia-1). Durante a condução do experimento foram realizadas avaliações de altura da planta (cm), diâmetro do caule (mm) e comprimento de ramos plagiotrópicos (cm) para determinar as respectivas taxas de crescimento vegetativo das plantas. As quantidades de fenóis totais determinadas nas plantas com produção (17.40 µg g-1 e 13.89 µg g-1 folhas dreno e fonte, respectivamente) e sem produção de café (18.65 µg g-1 e 12.76 µg g-1 folhas dreno e fonte, nessa ordem) não variaram. No entanto, a concentração de fenóis totais nas folhas novas (dreno) das plantas com e sem produção de café foi maior que a quantidade determinada nas folhas maduras (fonte), da ordem de 25 % e 46 %, respectivamente. A síntese de fenóis nas fases de expansão (16.35 µg g-1) e granação dos frutos (14.68 µg g-1) foi 31 % inferior em relação às quantidades determinadas na fase de maior produção dessas substâncias - fruto em maturação (21.24 µg g-1). A metabolização de fenóis totais depende, indiretamente, da temperatura (oC) e da radiação global (MJ m-2 dia-1), apresentando tendência inversa em relação a estas variáveis climáticas. A orientação do manejo fitossanitário deve levar em consideração as épocas em que há comprometimento da defesa natural da planta, em relação à produção de substâncias protetivas - os fenóis. / The vegetables show a natural defense against external factors, biotic and abiotic, by the synthesis of the phenolic compounds in the secondary metabolism, which varies with the maturity state and with the climate. The increase of phenolic compounds in the plants is directly related to the resistance to the infection thought pathogens and insect infestation. However, little is known about the variation in the content of this substance during the maturity state of the coffee tree, particularly in the fructification phases due to the climatic variations. Such knowledge is the base for the risks analyses of attacks to vegetables, since the natural defense of the plant shall change during the cycle. The experiment was carried out in a Coffea arabica L. crop, to cultivar Obatã IAC 1669-20, installed in the experimental field of the department of vegetal production of the Escola Superior de Agricultura "Luiz de Queiroz", University of São Paulo, Piracicaba/SP. For the accomplishment of the experiment it was adopted a totally randomized experimental design, using four treatments (plants with and without fruits - drain leaves and plants with and without fruits - source leaves) and five repetitions consisting of individual plants. After analysing the variance of the results it was applied Student t test at the level of 5 % of significance to compare the averages between the treatments. The total phenol grade (µg g-1) have been extracted from the mature (source) and new (drain) leaves and have been analyzed in relation to the coffee yield, phenology and climate. The climatic conditions adopted were atmospheric temperature (average, minimum and maximum; oC), global radiation (MJ m-2 day-1) and daily insolation (h day-1). During the conduction of the experiment it was analyzed the evaluations of the height (cm), diameter (mm) and length of the reproductive branches (cm) to determine the respective vegetative growth rates of the plants. The determined amounts of total phenols in the plants with production (17.40 µg g-1 and 13.89 µg g-1 drain and source leaves, respectively) and without coffee production (18.65 µg g-1 and 12.76 µg g-1 drain and source leaves, respectively) did not varied. However, the total phenol concentrations in new leaves of the plants with and without coffee production were greater than the amount determined in mature leaves around 25 % and 46 %, respectively. The secondary substance synthesis in the phases of expansion (16.35 µg g-1) and grain filling of the fruits (14.68 µg g-1) was 31% lower than the amounts determined in the phase of the greatest production of these substances - fruit in maturation (21.24 µg g-1). The total phenol metabolization depends indirectly on the temperature (oC) and on the global radiation (MJ m-2 day-1), presenting inverse trend in relation to these climatic variable. The orientation of the crop protection managing shall take into consideration the period when it has endangerment of the natural defense of the plant.
957

Influencia del entorno acústico laboral en el comportamiento audiométrico y su correlación con el registro de otoemisiones acústicas de productos de distorsión

Burgos Sánchez, Antonio Jesús 17 July 2015 (has links)
El ruido puede ser considerado el contaminante físico con mayor presencia en el mundo laboral. La exposición continuada sin la protección adecuada, a niveles sonoros de elevada intensidad constituye ineludiblemente un riesgo potencial para la salud. El efecto nocivo del ruido en el medio laboral se traduce en una pérdida auditiva o hipoacusia que generalmente es progresiva e irreversible, y que estaría encuadrada dentro de la denominada pérdida auditiva inducida por ruido (PAIR). La evaluación y diagnóstico de la PAIR en el medio laboral se ha basado clásicamente en la realización de audiometrías, pero existen en la actualidad otros métodos diagnósticos que podrían ser de utilidad, entre los que se encuentra el registro de las otoemisiones acústicas de productos de distorsión (OEAPD). En el estudio se conjugan los siguientes factores: determinación y descripción del clima acústico (dosis de ruido, mapa de niveles de presión sonora, composición espectral del ruido), evaluación y análisis de los resultados audiométricos en relación al espectro de frecuencia e intensidad del clima acústico, correlación de los resultados audiométricos con los registros de OEAPD. La población objeto de estudio está compuesta por un total de 184 sujetos expuestos al ruido en el medio laboral de forma prolongada (aquellos en cuyos puestos de trabajo el nivel de ruido diario equivalente superaba los 80 dBA, teniendo todos ellos una historia de exposición superior a 10 años). Sólo fueron incluidos en el estudio un total 134 sujetos que cumplían los siguientes requisitos: Ausencia de patología ótica infecciosa, ausencia de exposición a ruido extralaboral, ausencia de ingesta de ototóxicos, ausencia de antecedentes familiares de trastornos de la audición, exploración otoscópica normal e impedanciometría con curva de timpanograma tipo “A” y reflejos estapediales presentes. Para la realización del estudio se dispuso del siguiente material técnico: sonómetros Brüel-Kjaer, tipo 2222, Rion NA-27 y Rion NL-05, dosímetros Quest Q100 y Q 500, analizador frecuencial Brüel-Kjaer tipo 2144, otoscopio de la marca Riester, impedanciómetro Handtymp 300, audiómetro y registro OEAPD mediante el equipo “porta REM 2000 Digital. PR 2000” de Rastronic. El estudio se ha llevado a cabo en la fábrica de tabacos que Altadis (Tabacalera) poseía en Alicante. Se realizaron dosimetrías a 25 sujetos, abarcando los distintos puestos de trabajo, con dos metodologías diferentes (Dosímetros Quest Q100 y Q 500: Dosis recibida por trabajador cada jornada de 7,5 horas. Sonómetro integrador Rion NA-27: Medidas de nivel diario equivalente). Se realizaron, además mapas de nivel de presión sonora y determinación de la distribución espectral de la maquinaria. Todos los sujetos fueron examinados mediante otoscopia, impedanciometría, audiometría tonal liminar vía aérea/vía ósea en las frecuencias de 0.25, 0.5, 1, 2, 4, 6 y 8 kHz y registro de OEAPD en las frecuencias 3, 4 y 6 kHz. La dosimetría con cada metodología arrojó valores del nivel equivalente entre 85-92 dBA, alcanzando dosis con valores entre 1-4 Pa2 x h, (1Pa2 x h = 85 dBA). En el mapa de ruidos se pudo determinar cómo los niveles rebasaban continuamente los 80 dBA. En la distribución espectral cabe resaltar la aparición de picos muy marcados en torno a 250 Hz. El patrón audiométrico de los sujetos pone de manifiesto una incidencia mayor de la esperada de afectación en las frecuencias graves (0.25 y 0.5 kHz). Entre las frecuencias agudas la más afectada es 6 kHz. En los resultados de OEAPD de la población estudiada se aprecia un descenso de su incidencia en las frecuencias de 3, 4 y 6 kHz (igual que ocurre con los resultados de la audiometría, la frecuencia más afectada es 6 kHz). La correlación de los resultados audiométricos con los registros de OEAPD en un subgrupo (n = 50) caracterizado, por altos niveles de exposición durante más de 10 años, puso de manifiesto la afectación de las OEAPD aun cuando el umbral audiométrico estaba preservado. La presencia de altos niveles de contaminación acústica en el medio laboral, durante largos periodos de tiempo, está en relación directa con la aparición de deterioro auditivo. En este sentido tanto las mediciones de nivel equivalente como la de dosis recibidas se consideran métodos válidos, siendo éste más clarificador sobre la dosis real recibida. Dado que los valores del nivel equivalente oscilan entre 85-92 dBA, y que las dosis recibidas arrojan valores de 1-4 Pa² x h, se puede concluir que la población estudiada está inmersa en un clima de alta contaminación acústica. El audiograma típico de un sujeto que sufre PAIR por lo general presenta una pérdida máxima a 4 kHz con crecimiento gradual de la pérdida auditiva que acaba afectando a otras frecuencias. Por otra parte, si un ruido tiene la mayor parte de su energía en la región de una frecuencia particular, el daño máximo se manifestará en una frecuencia alrededor de una octava por encima de la del ruido. El patrón audiométrico de nuestra población pone de manifiesto una incidencia mayor de la esperada de afectación en las frecuencias graves, que pensamos está en relación con el espectro de emisión de la maquinaria de producción. El comportamiento audiométrico de la población estudiada se presentan con un patrón de PAIR donde se afecta predominantemente 6 kHz, en lugar de 4 kHz cómo cabría esperar. Existe una correlación positiva entre el grado de afectación audiométrica por exposición laboral al ruido y la baja incidencia de OEAPD en dichas frecuencias, sugiriéndose una mayor sensibilidad y precocidad de esta prueba en la detección de la lesión coclear por ruido.
958

Estabilidade operacional assegurada por metodologias kaizen lean na Amorim & Irmãos, SA - UI Champcork

Batista, Luís Pedro Faria January 2012 (has links)
Trabalho realizado na Amorim & Irmãos - UI Champcork, orient. pelo Eg.º Luís Moreira / Tese de Mestrado Integrado. Engenharia Industrial e Gestão. Faculdade de Engenharia. Universidade do Porto. 2013
959

Optimización de la calidad de un suelo agrícola por la aplicación de compost y abono sintético en Pampa del Arco, Ayacucho

Tineo Bermúdez, Alex Lázaro January 2014 (has links)
Publicación a texto completo no autorizada por el autor / Determina la mezcla de abonos: natural orgánico, y sintético, que optimice la calidad de un suelo agrícola, utilizando un suelo agrícola de la localidad de Pampa del Arco, Ayacucho; el mismo que estuvo en descanso bajo cobertura de Pennisetum clandestinum, por un período de cinco años. La unidad experimental consiste en baldes plásticos para 20 kg de suelo con cultivo de tomate. Se utiliza el diseño 03 de julio, que evalúa cinco niveles para cada uno de los factores en estudio (a: abono natural, compost; b: fertilizantes sintéticos, NPK). Se evalúan dos variables: “calidad del suelo” y “salud del cultivo”. Los resultados encontrados permiten arribar a las conclusiones siguientes: la calidad del suelo sufre cambios significativos según la mezcla de abonos, siendo más perjudiciales las que llevan altos niveles de abono sintético; por el contrario el abono orgánico contribuye a mantener una adecuada tasa de infiltración del agua en el perfil del suelo. La aplicación de abono sintético puro, sin acompañar con compost, afecta la actividad microbiana del suelo. El menor impacto negativo sobre la infiltración del agua en el perfil del suelo, se consigue aplicando mezclas de un mínimo de 5 t.ha-1 de compost con 80-90-70 kg.ha-1 de NPK, o mezclas de un mínimo de 7,5 t.ha-1 de compost con 160-180-140 kg.ha-1 de NPK. El mejor nivel de calidad del suelo estimada por efecto de la mezcla de compost y abono sintético corresponde a la mezcla de 10 t.ha-1 de compost y 160-180-140 kg.ha-1 de NPK. Los modelos que predicen la influencia del abono orgánico (compost) y del abono sintético en la calidad del suelo y salud del cultivo, son: Y = 22,74 + 2,0949X1 - 4,3154X2 + 0,8430X1² - 0,5648X2² + 0,2771X1X2, para la tasa de infiltración del agua a través del perfil del suelo; Y = 805,9 + 35,98462X1 + 52,72179X2 + 2,20291X1² - 10,23337X2² - 9,05208X1X2, para el rendimiento de frutos de tomate. / Tesis
960

Ilhas de calor urbanas em São Carlos, SP e os impactos da permeabilidade dos revestimentos urbanos horizontais / Urban heat island in São Carlos, SP and the impact of permeability of horizontal urban coatings

Galusic, Bojana 31 May 2019 (has links)
O fenômeno de ilhas de calor urbanas ocorre principalmente nos centros urbanos caracterizados pela grande concentração de edificações, ausência de vegetação e uso de materiais impermeáveis com grande capacidade de armazenar calor. As temperaturas elevadas causam desconforto térmico, problemas de saúde e maior consumo de energia para resfriamento de edificações. O objetivo da pesquisa presente é investigar o impacto da permeabilidade dos revestimentos urbanos horizontais na variação da temperatura do ar e na formação de ilhas de calor urbanas na cidade de São Carlos, SP. Embora São Carlos seja uma cidade de porte médio, o processo da urbanização criou áreas densamente construídas e sem muita vegetação, o que favorece o aquecimento do ar e das superfícies. Para avaliar a variação da temperatura do ar em relação às características urbanas, foram realizadas medições fixas da temperatura e umidade relativa do ar em 37 pontos que representam diferentes tipos de ocupação urbana em quatro estações do ano, durante 15 dias em cada estação. Nos entornos dos pontos de medição foi feito o mapeamento da permeabilidade dos revestimentos horizontais das superfícies. A correlação entre as variáveis climáticas e urbanísticas foi analisada para cada estação separadamente e a seguir fez-se a análise comparativa de todas as estações através da normalização dos dados climáticos obtidos por monitoramento. A partir dos dados normalizados foram elaborados mapas térmicos. Os resultados confirmam o aumento da temperatura e diminuição da umidade em locais onde predominam revestimentos impermeáveis. Desse modo, este estudo fornece subsídios importantes para o planejamento urbano, a fim de criar espaços urbanos termicamente confortáveis na cidade de São Carlos. / The phenomenon of urban heat island occurs principally in urban centers characterized by big concentration of buildings, absence of vegetation and use of impermeable materials with high capacity to store heat. Elevated temperatures cause thermal discomfort, health problems and higher energy consumption for cooling of the buildings. The objective of the present research is to investigate the impact of permeability of horizontal urban coatings on the variation of air temperature and formation of urban heat islands in the city of São Carlos, SP. Although São Carlos is a medium sized city, the process of urbanization created densely built up areas without a lot of vegetation, which benefits the heating of air and surfaces. In order to evaluate the temperature variation in relation to urban characteristics, fixed measurements of air temperature and humidity were be performed in 37 points which represent different types of urban occupation in four season of the year, during 15 days in each season with interval of 30 minutes. In the surroundings of each point of measurement was performed a mapping of permeability of horizontal coatings. The correlation between climatic and urbanistic variables was analyzed for each season separately and following was done a comparative analysis of all the seasons by the use of normalization and extrapolation of climatic data. Based on the normalized data were elaborated temperature maps. The results confirm the increase in temperature and the decrease in humidity in the locations where impermeable coatings dominate. Thus, this study provides important supplies for urban planning, in order to create thermally comfortable urban spaces in the city of São Carlos.

Page generated in 0.0425 seconds