• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1019
  • 300
  • 102
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 1414
  • 550
  • 447
  • 443
  • 275
  • 271
  • 246
  • 203
  • 179
  • 170
  • 167
  • 163
  • 152
  • 141
  • 140
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
731

Commande robuste référencée intention d'une orthèse active pour l'assistance fonctionnelle aux mouvements du genou / Robust and intention-based control of an active orthosis for assistance of knee movements

Mefoued, Saber 12 December 2012 (has links)
Le nombre croissant de personnes âgées dans le monde exige de relever de nouveaux défis sociétaux, notamment en termes de services d'aide et de soins de santé. Avec les récents progrès technologiques, la robotique apparaît comme une solution prometteuse pour développer des systèmes visant à faciliter et améliorer les conditions de vie de cette population. Cette thèse vise la proposition et la validation d'une approche de commande robuste et référencée intention d'une orthèse active, destinée à assister des mouvements de flexion/extension du genou pour des personnes souffrant de pathologies de cette articulation. La commande par modes glissants d'ordre 2 que nous proposons permet de prendre en compte les non-linéarités ainsi que les incertitudes paramétriques résultant de la dynamique du système équivalent orthèse-membre inférieur. Elle permet également de garantir d'une part, un bon suivi de la trajectoire désirée imposée par le thérapeute ou par le sujet lui-même, et d'autre part, une bonne robustesse vis-à-vis des perturbations externes pouvant se produire lors des mouvements de flexion/extension. Dans cette thèse, nous proposons également un modèle neuronal de type Perceptron Multi-Couches pour l'estimation de l'intention du sujet à partir de la mesure des signaux EMG caractérisant les activités musculaires volontaires du groupe musculaire quadriceps. Cette approche permet de s'affranchir d'un modèle d'activation et de contraction musculaire complexe. L'ensemble des travaux a été validé expérimentalement avec la participation volontaire de plusieurs sujets valides / The increasing number of elderly in the world reveals today new societal challenges, particularly in terms of healthcare and assistance services. With recent advances in technology, robotics appears as a promising solution to develop systems that improve the living conditions of this aging population. This thesis aims at proposing and validating an approach for robust control of an active orthosis, based on the subject intention. This orthosis is designed to assist flexion/ extension movements of the knee for people suffering from knee joint deficiencies. The proposed second order sliding mode control allows to take into account the nonlinearities and parametric uncertainties resulting from the dynamics of the equivalent lower limb-orthosis system. It also ensures on one hand, a good tracking performance of the desired trajectory imposed by the therapist or the subject itself, and on the second hand, a satisfactory robustness with respect to external disturbances that may occur during flexion and extension of the knee joint. In this thesis, a neural model based on Multi-Layer Perceptron is used to estimate the subject's intention from the measurement of the EMG signals characterizing the voluntary activities of the quadriceps muscle group. This approach overcomes the complex modeling of the muscular activation and contraction dynamics. All the proposed approaches in this thesis have been validated experimentally with the voluntary participation of several healthy subjects
732

Allocation de fonctions de commande de systèmes critiques par recherche d'atteignabilité dans un réseau d'automates communicants / Mapping of control functions of critical systems by reachability analysis in a network of communicating automata

Lemattre, Thibault 09 July 2013 (has links)
La conception d'architectures opérationnelles d'un système de contrôle-commande est une phase très importante lors de la conception de systèmes de production d'énergie. Cette phase consiste à projeter l'architecture fonctionnelle sur l'architecture organique tout en respectant des contraintes de capacité et de sûreté, c'est-à-dire à allouer les fonctions de commande à un ensemble de contrôleurs tout en respectant ces contraintes. Les travaux présentés dans cette thèse proposent : i)une formalisation des données et contraintes du problème d'allocation de fonctions - ii)une méthode d'allocation, par recherche d'atteignabilité, basée sur un mécanisme d'appel/réponse dans un réseau d'automates communicants à variables entières - iii)la comparaison de cette méthode à une méthode de résolution par programmation linéaire en nombres entiers. Les résultats de ces travaux ont été validés sur des exemples de taille réelle et ouvrent la voie à des couplages entre recherche d'atteignabilité et programmation linéaire en nombres entiers pour la résolution de problèmes de satisfaction de systèmes de contraintes non linéaires. / The design of operational control architectures is a very important step of the design of energy production systems. This step consists in mapping the functional architecture of the system onto its hardware architecture while respecting capacity and safety constraints, i.e. in allocating control functions to a set of controllers while respecting these constraints. The work presented in this thesis presents: i) a formalization of the data and constraints of the function allocation problem- ii) a mapping method, by reachability analysis, based on a request/response mechanism in a network of communicating automata with integer variables- iii) a comparison between this method and a resolution method by integer linear programming. The results of this work have been validated on examples of actual size and open the way to the coupling between reachability analysis and integer linear programming for the resolution of satisfaction problems for non-linear constraint systems.
733

Génération de codes et d'annotations prouvables d'algorithmes de points intérieurs à destination de systèmes embarqués critiques / Generation of codes and provable annotations of interior-point algorithms for critical embedded systems

Davy, Guillaume 06 December 2018 (has links)
Dans l'industrie, l'utilisation de l'optimisation est omniprésente. Elle consiste à calculer la meilleure solution tout en satisfaisant un certain nombre de contraintes. Cependant, ce calcul est complexe, long et pas toujours fiable. C'est pourquoi cette tâche est longtemps restée cantonnée aux étapes de conception, ce qui laissait le temps de faire les calculs puis de vérifier que la solution était correcte et si besoin refaire les calculs. Ces dernières années, grâce à la puissance toujours grandissante des ordinateurs, l'industrie a commencé à intégrer des calculs d'optimisation au cœur des systèmes. C'est-à-dire que des calculs d'optimisation sont effectués en permanence au sein du système, parfois des dizaines de fois par seconde. Par conséquent, il est impossible de s'assurer a posteriori de la correction d'une solution ou de relancer un calcul. C'est pourquoi il est primordial de vérifier que le programme d'optimisation est parfaitement correct et exempt de bogue.L'objectif de cette thèse a été de développer outils et méthodes pour répondre à ce besoin.Pour ce faire, nous avons utilisé la théorie de la preuve formelle qui consiste à considérer un programme comme un objet mathématique. Cet objet prend des informations en entrée et produit un résultat. On peut alors, sous certaines conditions sur les entrées, prouver que le résultat satisfait nos exigences. Notre travail a consisté à choisir un programme d'optimisation puis à prouver formellement que le résultat de ce programme est correct. / In the industry, the use of optimization is ubiquitous. Optimization consists of calculating the best solution subject to a number of constraints. However, this calculation is complex,long and not always reliable. This is why this task has long been confined to the design stages,which allowed time to do the computation and then check that the solution is correct and if necessary redo the computation. In recent years, thanks to the ever-increasing power of computers, the industry has begun to integrate optimization computation at the heart of the systems. That is to say that optimization computation is carried out continuously within the system, sometimes dozens of times per second. Therefore, it is impossible to check a posteriori the solution or restart a calculation. That is why it is important to check that the program optimization is perfectly correct and bug-free. The objective of this thesis was to develop tools and methods to meet this need. To do this we have used the theory of formal proof that is to consider a program as a mathematical object. This object takes input data and produces a result. We can then, under certain conditions on the inputs, prove that the result meets our requirements. Our job was to choose an optimization program and formally prove that the result of this program is correct.
734

Modular Multilevel Converter Control for HVDC Operation : Optimal Shaping of the Circulating Current Signal for Internal Energy Regulation / Commande adaptée pour le convertisseur modulaire multiniveaux pour les liaisons à courant continues

Bergna Diaz, Gilbert 03 July 2015 (has links)
Dans le cadre du programme de croissance Européen 2020, la commission européenne a mis en place officiellement un chemin à long terme pour une économie à faible émission de carbone, en aspirant une réduction d’au moins 80% des émissions de gaz à effet de serre, d’ici 2050. Répondre à ces exigences ambitieuses, impliquera un changement majeur de paradigme, et notamment en ce qui concerne les infrastructures du réseau électrique. Les percées dans la technologie des semi-conducteurs et les avancées avec les nouvelles topologies d’électronique de puissance et leurs contrôle-commandes, ont contribué à l’impulsion donnée au processus en cours de réaliser un tel SuperGrid. Une percée technologique majeure a eu lieu en 2003, avec le convertisseur modulaire multi-niveaux (MMC ou M2C), présenté par le professeur Marquardt, et qui est actuellement la topologie d’électronique de puissance la plus adaptée pour les stations HVDC. Cependant, cette structure de conversion introduit également un certain nombre de défis relativement complexes tels que les courants “additionnels” qui circulent au sein du convertisseur, entrainant des pertes supplémentaires et un fonctionnement potentiellement instable. Ce projet de thèse vise à concevoir des stratégies de commande “de haut niveau” pour contrôler le MMC adaptées pour les applications à courant continue-haute tension (HVDC), dans des conditions de réseau AC équilibrés et déséquilibrés. La stratégie de commande optimale identifiée est déterminée via une approche pour la conception du type “de haut en bas”, inhérente aux stratégies d’optimisation, où la performance souhaitée du convertisseur MMC donne la stratégie de commande qui lui sera appliquée. Plus précisément, la méthodologie d’optimisation des multiplicateurs de Lagrange est utilisée pour calculer le signal minimal de référence du courant de circulation du MMC dans son repère naturel. / Following Europe’s 2020 growth program, the Energy Roadmap 2050 launched by the European Commission (EC) has officially set a long term path for a low-carbon economy, assuming a reduction of at least 80% of greenhouse gas emissions by the year 2050. Meeting such ambitious requirements will imply a major change in paradigm, including the electricity grid infrastructure as we know it.The breakthroughs in semi-conductor technology and the advances in power electronics topologies and control have added momentum to the on-going process of turning the SuperGrid into a reality. Perhaps the most recent breakthrough occurred in 2003, when Prof. Marquardt introduced the Modular Multilevel Converter (MMC or M2C) which is now the preferred power electronic topology that is starting to be used in VSC-HVDC stations. It does however, introduce a number of rather complex challenges such as “additional” circulating currents within the converter itself, causing extra losses and potentially unstable operation. In addition, the MMC will be required to properly balance the capacitive energy stored within its different arms, while transferring power between the AC and DC grids that it interfaces.The present Thesis project aimed to design adequate “high-level” MMC control strategies suited for HVDC applications, under balanced and unbalanced AC grid conditions. The resulting control strategy is derived with a “top-to-bottom” design approach, inherent to optimization strategies, where the desired performance of the MMC results in the control scheme that will be applied. More precisely, the Lagrange multipliers optimization methodology is used to calculate the minimal MMC circulating current reference signals in phase coordinates, capable of successfully regulating the capacitive arm energies of the converter, while reducing losses and voltage fluctuations, and effectively decoupling any power oscillations that would take place in the AC grid and preventing them from propagating into the DC grid.
735

Enfouissement d’une alimentation isolée sous contraintes de température et d’isolation / Integration of an insulated power supply under temperature and insulation constraints

Wanderoild-Morand, Yohan 10 October 2018 (has links)
Certaines applications haute température telles que le forage, l’aéronautique ou l’aérospatial, amènent à repenser la conception des alimentations isolées permettant la commande des éléments de puissance. Ce mémoire s’articule autour de l’étude de la faisabilité et de l’enfouissement d’un convertisseur isolé possédant une forte isolation statique (10kV) et dynamique (<10 pF), pouvant travailler sous de hautes températures (>250°C), dans les gammes de tension de sortie de la dizaine de volts et de puissance de l’ordre du Watt. Pour ne pas être contraint par la température de Curie d’un matériau magnétique, cette alimentation DC/DC se base sur un transformateur à air. Dans un premier temps, cette thèse détaille l’origine, la mesure et l’estimation des éléments du modèle électrique choisi pour le transformateur. Ensuite, afin de maximiser la transmission de puissance, nous constituons un système résonnant en ajoutant des condensateurs en parallèle ou en série avec le transformateur, puis nous développons une méthode permettant d’accorder l’ensemble. La comparaison entre les topologies nous amène ensuite à choisir compensation série-série. Puis nous constatons que la technologie choisie pour les condensateurs, la contrainte d’isolation statique et dynamique peuvent diviser par plus de deux la puissance transmise au travers d’une surface. Enfin, nous abordons comment redresser et réguler la tension de sortie sans affecter la résonnance ou l’isolation apportée, tout en minimisant les pertes générées. Une dernière partie montre que, moyennant un système de dissipation un processus de fabrication adapté, il est possible d’intégrer la structure complète sur silicium / High temperature applications such as deep drilling, aeronautics or aerospace, lead to rework the isolated power supplies used for the control of the power elements. This work study the feasibility of an embedded converter with high static (10kV) and dynamic (<10 pF) insulation, able to work under high temperatures (> 250 ° C), in the ranges of dozens volts for the output voltage and several Watt of transmitted power. To avoid being constrained by a magnetic material Curie temperature of, we use a coreless transformer based DC/DC power supply. First of all, this thesis details the origin, the measurement and the estimation of the elements of the chosen transformer electric model. Then, to maximize the transferred power, we form a resonant structure by adding capacitors in parallel or in series with the transformer, then we develop a method to tune the whole. The comparison between the topologies leads us to choose a serial-serial compensation. Then we note that the technology chosen for capacitors, the static and dynamic insulation constraint can divide by more than two the power transmitted through a surface. Finally, we discuss how to rectify and regulate the output voltage without affecting the resonance or insulation provided, while minimizing the losses generated. A last part exhibit that with a suitable dissipation system and manufacturing process, it is possible to integrate the complete structure on silicon chips
736

Etude de stratégies de gestion énergétique en temps réel à l'échelle multizone / Study of real time energy control strategies at multi-zone scale

Frapin, Marie 21 September 2018 (has links)
Pour faciliter la transition énergétique vers la réduction de la consommation des énergies fossiles, la réduction des émissions de CO2 et l’intégration des sources d’énergie renouvelables, il convient d’étudier des stratégies permettant d’adapter en temps réel la gestion énergétique de manière optimale par rapport aux contraintes extérieures et intérieures du bâtiment. Des leviers d’action existent à l’échelle de l’îlot comme la mutualisation des productions et des consommations. Cette thèse présente l’application de techniques d’optimisation au développement de stratégies de gestion du chauffage électrique d’un bâtiment multizone comportant des logements et des bureaux. Pour réduire les temps de calcul par rapport à une approche de résolution globale d’un problème d’optimisation à grande échelle, les méthodes de décomposition-coordination ont été étudiées. Ces méthodes permettent de résoudre des sous-problèmes d’optimisation à l’échelle de chaque zone et de réintégrer les couplages entre zones (couplages thermiques et partage d’une ressource) avec une étape de coordination. Une méthode décomposée-coordonnée a été retenue pour chaque type de couplage permettant la mise en place d’une gestion en temps réel à l’échelle multizone. / To facilitate the energy transition towards the reduction of fossil fuels consumption, CO2 emissions and the integration of renewable energy sources, it is necessary to study realtime management strategies to adapt energy management in an optimal way according to external and internal perturbations and the evolution of the building. Solutions exist at the scale of blocks of buildings such as production and consumption pooling. This thesis presents the development of real-time management strategies, using optimisation techniques, for the electric heating of a multi-zone building mixing residential and tertiary uses. To decrease computation time compared to a global resolution approach of large-scale optimisation problems, decomposition-coordination methods were studied. These methods consist in solving sub-problems of optimisation in each zone and reintegrating the links between zones (thermal couplings and resource sharing) using a coordination step. One of these methods was chosen for each type of coupling allowing the implementation of real-time management at a multi-zone scale.
737

Contribution au diagnostic et à la commande de la pile à combustible de type PEM / Contribution to the diagnosis and control of PEM fuel cell

Niane, Moustapha 09 October 2018 (has links)
La pile à combustible (PàC) est un dispositif qui transforme l'énergie chimique en énergie électrique. Ce dispositif nécessite un certain nombre d’auxiliaires pour son fonctionnement. Afin d'assurer des performances en termes de sécurité, de fiabilité et de durée de vie de la PàC, des systèmes de diagnostic et de commande adéquats sont indispensables. Ainsi, cette thèse est une contribution au problème du diagnostic de défauts et à la commande de la PàC de type PEM. Le premier volet de ce travail est consacré au développement de méthodes de diagnostic appliquées à la PàC. Pour ce faire, deux approches ont été proposées. La première concerne la synthèse d’un filtre H-/H∞ permettant la détection de défauts capteurs et actionneurs tout en assurant un niveau de robustesse vis-à-vis d'éventuelles perturbations. En tenant compte des caractéristiques du système de la PàC, les conditions d'existence et de stabilité du filtre sont données sous la forme de LMI. La seconde approche traite le problème de la détection des défauts paramétriques. Pour cet objectif, un observateur adaptatif a été proposé, ce dernier permet d'estimer la valeur du paramètre susceptible de présenter une défaillance. Cette méthode donne la possibilité d'estimer simultanément les défauts paramétriques et les états non mesurés du système. Le deuxième volet de la thèse est dédié à la commande du système PàC. Le but est de synthétiser une loi de commande par rétroaction qui permet de répondre à la sollicitation de la charge tout en respectant une contrainte de fonctionnement nominal de la PàC. La synthèse de cette loi de commande a été réalisée en prenant compte tout le caractère non linéaire du système / The fuel cell is a device that transforms the chemical energy in electricity. This device requires some auxiliaries for its operation. In order to ensure the performances in terms of security, reliability and life cycle of the fuel cell, adequate diagnostic and control systems are indispensables. This thesis is a contribution to the problem of faults diagnosis and control of PEM Fuel Cell. The first part of this work is dedicated to the development of diagnostic methods applied to the fuel cell. To do this, two approaches are proposed. The first one concerns the synthesis of a H-/H∞ filter allowing the sensors and actuators faults detection while ensuring a level of robustness towards disturbances. Taking into account the fuel cell system characteristics, the conditions for existence and stability of the filter are given in the form of Linear Matrix Inequalities (LMI). The second approach deals with the problem of parametric faults detection. For this purpose, an adaptive observer has been proposed, which makes it possible to estimate the value of the parameter likely to exhibit a failure. This method gives the possibility of simultaneously estimating the parametric faults and the unmeasured states of the system. The second part of the thesis is dedicated to the control of the fuel cell system. The purpose is to synthesize a feedback control law that allows to answer the load request while respecting a nominal operating constraint of the fuel cell. Such a functioning allows to have a better efficiency while preserving the state of health of the fuel cell. The control law is obtained by using the original nonlinear model and without any kind of linearization
738

Contribution aux méthodes de conception et de gestion des systèmes énergétiques multi-sources par optimisation systémique : application aux trains hybrides électrique autonomes / Contribution to design methods and management of multi-sources energy system by systemic optimization : application to hybrid electric trains and autonomous

Poline, Marie 28 November 2018 (has links)
En France, il existe deux modes de traction pour les trains : la traction diesel ou la traction électrique. Chaque mode fait face à des problématiques qui lui sont propres. Dans le cas du diesel, les émissions de gaz à effet de serre étant de plus en plus contrôlées, il devient nécessaire de faire évoluer ce type de train vers une solution moins polluante. Dans le cas de la traction électrique, la consommation d’énergie entraine une chute de tension qui peut imposer un ralentissement des trains, empêchant ainsi le développement du trafic. La solution étudiée par la SNCF est l’hybridation des trains (ajout de systèmes de stockage en embarqué).Ces travaux de thèse ont pour objectif de mettre en place une méthode permettant de faire le pré-dimensionnement des systèmes de stockage embarqués dans le train. De plus, afin de tenir compte de l’influence réciproque de la gestion sur le dimensionnement, celle-ci est incluse dans le modèle de dimensionnement. La résolution du modèle global se fait à l’aide d’un algorithme d’optimisation.La méthode a été mise en place sur les deux modes de traction ferroviaire (diesel et électrique) et l’optimisation a été faite avec l’algorithme SQP (Sequential Quadratic Programming). / In France, there are two traction modes for railway: the diesel and electric traction. Each mode has its own issues. For diesel, the increasing control of the greenhouse gas emissions imposes to evolve this type of train to a less polluting solution. For electric traction, the energy consumption creates a voltage drop which can cause a traffic slowdown, which will limit the traffic development. The studied solution by SNCF is the hybridization of the train (adding storage system).Thus, these works have the objective to build a method to do the pre-sizing of storage systems embedded in trains. Moreover, to take into account the mutual influence of the sizing and the energy management, this last one is included in the sizing model. An optimization algorithm solves the global model.The method has been developed for the two traction modes (diesel and electric) and the optimization has been made with SQP algorithm (Sequential Quadratic Programming).
739

Vérification formelle et Simulation pour la Validation du système de contrôle commande des EALE (Équipements d'Alimentation des Lignes Électrifiées) / Formal verification and simulation for the validation of PSEEL's control systems (Power Supply Equipment of the Electric Lines)

Niang, Mohamed 20 December 2018 (has links)
La SNCF cherche à mettre en place des solutions innovantes permettant d’améliorer la sécurité et les conditions de travail des chargés d’études lors des travaux d’automatisation. En partant de l’étude théorique du projet jusqu’à sa validation sur site, en passant par la mise en œuvre des programmes, du câblage des armoires, et de leur vérification sur plateforme et en usine, ces différentes tâches s’avèrent souvent être longues, complexes, et répétitives, ce qui a pour effet d’augmenter la charge de travail des chargés d’études. En vue d’améliorer les conditions de travail des chargés d’études, ce projet de recherche vise principalement à améliorer leurs méthodologies de vérification des programmes API (aspects fonctionnels et sécuritaires) et du câblage des armoires électriques. Ce projet intitulé « Vérification formelle et simulation pour la validation des programmes API des EALE » se décompose en deux axes :  la vérification hors ligne des programmes API : basée sur une approche formelle, la méthode s’appuie sur une modélisation de l’installation électrique, des programmes API et du cahier de recette dans le model-checker Uppaal. Le principe consiste à vérifier automatiquement si les programmes satisfont aux tests du cahier de recette.  la vérification en ligne du câblage des armoires de contrôle/commande/ protection grâce à un simulateur de partie opérative interfacé avec les armoires de contrôle/commande/protection (via une armoire de test). La vérification se fera de manière automatique et en ligne, toujours avec les tests du cahier de recette, et permettra de valider le câblage des armoires et les réglages des appareils de protection numérique. / In order to keep its leadership in French rail market and to improve working conditions of its systems engineers during automation projects, the SNCF (French acronym for National Society of French Railways) wants to develop solutions increasing the productivity. One of these improvements focuses on the current methodology used by the systems engineers to verify and validate the control command system of electrical installations. This task remains one of the most important during an automation project because it is supposed to ensure installations safety, but it should be optimized. Through an industrial thesis financed by SNCF, the aim of this research project is to improve this method and reduce time validation of control command system by providing tools which will help systems engineers to verify and validate quickly and automatically the control command system during any automation project. It is composed of two axes : - Offline verification of PLC programs with model checking - Online validation of electrical cabinets with virtual commissioning
740

Structures et stratégies de commande des filtres actifs parallèle et hybride avec validations expérimentales / Structures and control strategies of parallel active and hybrid filters with experimental validations

Abdusalam, Mohamed Muftah 29 May 2008 (has links)
Ce manuscrit est consacré à la dépollution des réseaux électriques par les filtres actifs. Dans un premier temps, le filtre actif parallèle triphasé trois fils à structure tension y est étudié théoriquement, par simulation, puis expérimentalement. Une nouvelle stratégie de commande, basée sur la méthode des puissances instantanées et mettant en œuvre des « filtres multi-variables » est étudiée. Trois types de contrôleurs de courant sont envisagés : hystérésis classique, hystérésis modulée et MLI. L’hystérésis modulée est retenue car elle garantit simultanément la robustesse du système et une fréquence de commutation fixe. Un banc expérimental a permis de conforter les résultats obtenus par simulation. Ensuite, le filtre hybride parallèle (FHP) triphasé et l’optimisation de sa commande ont été examinés. L’objectif majeur est d’améliorer les performances de filtrage tout en s’attachant à minimiser la complexité de la commande. Le filtre hybride étudié est constitué d’un filtre actif triphasé à structure tension connecté en série avec un filtre triphasé passif de type LC, accordé sur l’harmonique 7. Nous avons proposé une première modification (commande dite « simplifiée ») de la commande classique dans le référentiel lié au synchronisme en introduisant des « filtres multi-variables » au lieu des filtres d’extraction classiques des deux boucles de contrôle, dites « feedback » et « feedforward ». Cette modification nous a permis de réduire considérablement la complexité de l’algorithme de commande (suppression de la PLL de la boucle « feedforward ») tout en améliorant les performances du filtrage. Ensuite, la PLL de la boucle « feedback » a également été supprimée. Ces optimisations ont conduit à des résultats de simulation très satisfaisants en terme de THD. Une nouvelle commande du filtre hybride à trois bras a également été proposée. La boucle feedforward est alors divisée en deux boucles. La première est destinée à supprimer l’harmonique 5 et l’autre l’harmonique 7 alors que le filtre passif est alors accordé sur l’harmonique 11. Les résultats de simulation obtenus sont très satisfaisants. Pour conclure cette étude théorique, nous avons étudié une nouvelle topologie de filtre hybride basée sur un onduleur triphasé à deux bras avec un condensateur à point milieu. Un flot de conception et d’implantation sur cible FPGA de commandes numériques de systèmes de puissance a été appliqué au cas de la commande dite « simplifiée » du FHP. Chaque étape a été détaillée et validée soit par simulation en mode continu ou en mode discret, soit expérimentalement lors de la programmation finale d’un composant FPGA de type Stratix II de la famille Altera, intégrant l’ensemble de la commande numérique du FHP. / In this thesis, and with the aim to improve the power quality, we have theoretically and experimentally studied two types of filtering, the shunt active power filter and hybrid, passive and active power filter. The modelling and simulation of a parallel active filter with three types of current controllers (MLI, classical hysteresis and modulated hysteresis) are first studied. The behavior of the active filter under transient conditions is also presented. Then, we have experimentally validated the simulation results obtained for the modulated hysteresis. The test bench consists of a parallel active filter, a non-linear load, a digital control system DSPACE (DS1104) and an analog card. Next, we studied by modelling and simulation the hybrid filter. For both cases, the use of multi-variable filter improves the filtering performances. An experimental prototype called "FPGA in the Loop" has been implemented to validate digital control of hybrid filter. In addition, a comparison between the two filters has been realised in order to find the best way to reduce network harmonic currents.

Page generated in 0.0432 seconds