• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 558
  • 6
  • 6
  • 6
  • 6
  • 6
  • 5
  • 5
  • Tagged with
  • 573
  • 339
  • 89
  • 78
  • 57
  • 52
  • 49
  • 47
  • 40
  • 40
  • 37
  • 36
  • 35
  • 34
  • 34
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
121

Calibração de arranjo para ensaios de detecção de fumaça em compartimentos de carga de aeronaves

Carolina Rodrigues Ramos Pinto 07 February 2013 (has links)
Na aviação existem requisitos que devem ser cumpridos para que uma aeronave esteja aeronavegável. Estes requisitos são aprimorados em função da evolução tecnológica e com a investigação de acidentes que resultam em lições aprendidas. O enfoque desta pesquisa é no requisito de segurança de cabine que aborda a detecção de fogo e fumaça dentro dos compartimentos de carga nas aeronaves. Trata-se do requisito FAR part 25, 25.858, para cujo cumprimento é necessária a instalação de detectores de fumaça nos compartimentos. Pela análise da literatura, verificou-se que existe uma grande subjetividade para a definição da fumaça ideal na realização dos ensaios de certificação das instalações do sistema de detecção de fumaça, uma vez que o critério utilizado é um vídeo disponibilizado pelo FAA (Federal Aviation Administration), porém vários fatores influenciam na escolha da fumaça ideal, como a iluminação do ambiente, ventilação, cor de fundo apresentados no vídeo. Dentro desse contexto essa pesquisa tem como objetivo principal determinar uma recomendação de calibração dos equipamentos utilizados para os ensaios de detecção de fumaça. Para atingir o objetivo principal, foram definidos objetivos específicos que incluem Definir a fumaça padrão através do Engineering judment de especialistas do ramo, propor uma instrumentação para a calibração da fumaça, caracterizar a fumaça através da instrumentação proposta. Diante desse cenário foi elaborado um procedimento experimental para avaliar diferentes fumaças, medi-las para identificar a resposta da instrumentação proposta por essa pesquisa, e conforme protocolo do procedimento, caracterizar a fumaça ideal através de dados mensuráveis de transmissibilidade. Os dados dos ensaios foram analisados com auxílio de ferramentas estatísticas. Os resultados mostraram que a instrumentação proposta é efetiva e foi determinada uma recomendação para a calibração dos equipamentos.
122

Método baseado em técnicas de processamento de imagens para calibração de feixe laser utilizado em aplicações dermatológicas / Method based on techniques of image processing for calibration laser beam in dermatological applications

Pecoraro, Wesley 29 April 2014 (has links)
A distribuição da energia espacial do feixe de laser é de grande importância para a eficiência em tratamentos dermatológicos. Os métodos existentes para a calibração do feixe podem ser realizados por meio de equipamentos óticos ou por materiais fotossensíveis. Este trabalho apresenta uma metodologia que pode ser descrita por quatro fases. Na primeira, foi obtido o polímero poliacetal, material que foi responsável por registrar o perfil transversal do feixe de laser (Nd:YAG 1064 nm). Na segunda fase os valores referenciais dos parâmetros do feixe foram extraídos por meio do método knife edge. Posteriormente, as técnicas de processamento de imagem foram aplicadas sendo responsáveis pela extração de características do feixe registradas no polímero. Como resultados, determinaram-se os seguintes parâmetros: área do feixe, circularidade, perfil da borda, assinatura, diâmetros, divergência e cintura do feixe. Na última fase o feixe foi classificado em calibrado e descalibrado por meio da Rede Neural Artificial (RNA) Multilayer Perceptron (MLP), que apresentou 88,5% de taxa de acertos. Outro parâmetro utilizado para a calibração foi a circularidade, onde adotou-se o valor limiar de 0,85 para decisão entre feixes calibrados e feixes descalibrados. Frente aos resultados obtidos, considera-se bem sucedida a proposta para a inspeção de qualidade de feixe laser para aplicação dermatológica, apresentando-se como um método de calibração alternativo com maior precisão quando comparado a análises por meio da visualização humana. / The spatial distribution of laser beam energy is of great importance to the efficiency of dermatologic treatments. The existing methods beam calibration can be performed with optical equipment or photosensitive materials. This paper presents a methodology which can be described by four phases. At first it was obtained polyacetal polymer, a material that was responsible for registering the transverse profile of the laser beam (Nd:YAG 1064 nm). In the second phase, the reference values of the beam parameters were extracted using the knife edge method. Subsequently, the image processing techniques were applied being responsible for extracting features of the beam recorded in the polymer. As a result, we determined the following parameters: beam area, circularity, the edge profile, signature, diameter, divergence and beam waist. In the last phase the beam was classified calibrated and uncalibrated with Artificial Neural Network (ANN) Multilayer Perceptron (MLP), which showed 88.5% hit ratio. Another parameter used for calibration was the circularity, where we adopted the threshold value of 0.85 for decision between calibrated and uncalibrated beams. Given our results, it is considered a successful proposal for the quality inspection of laser beam for dermatological application, presenting itself as an alternative method of calibration with greater precision when compared to analyzes by human viewing.
123

Análise quantitativa de alcanolaminas e CO2 no processo de absorção química via espectroscopia no infravermelho / Quantitative analysis of alkanolamines and CO2 in chemical absorption process by infrared spectroscopy

Tavares, Denise Trigilio 15 December 2015 (has links)
Em virtude da necessidade de se quantificar os carbamatos provenientes de processos de absorção química do gás CO2 por monoetanolamina (MEA) e dietanolamina (DEA), curvas analíticas por espectroscopia no infravermelho (IV) foram construídas visando à determinação do teor de carbamatos de MEA e DEA, além da quantificação de MEA, DEA e metildietanolamina (MDEA) em soluções puras e em misturas. O procedimento analítico compreendeu o preparo das amostras-padrão constituintes das curvas de calibração e suas quantificações com o emprego de técnicas instrumentais de referência titulação potenciométrica, pesagem e GC-FID. As amostras-padrão de aminas puras foram quantificadas por titulação potenciométrica, sendo possível a detecção exata do ponto de equivalência. As composições dos padrões analíticos de misturas foram estabelecidas segundo um diagrama triangular para misturas e o teor de cada componente foi determinado por gravimetria e GC-FID. Tanto a hidrólise quanto a degradação térmica dos carbamatos foram fatores que restringiram o emprego da titulação potenciométrica, HPLC-MS/MS e GC-FID como técnicas de referência em suas quantificações. Essas restrições, somadas ao fato de não haver disponibilidade comercial desses carbamatos, levaram ao uso da espectroscopia de RMN de 1H na determinação quantitativa. As curvas de calibração apresentaram ótimo ajuste dos valores preditos com relação aos de referência e erro máximo de predição de 0,594 %. Dois processos de absorção química do gás CO2 foram realizados em escala semipiloto e os resultados obtidos foram de 1,02 % e 0,98 % de CO2 absorvido por solução de MEA e DEA, respectivamente. Os mesmos processos foram simulados no software Aspen Plus, obtendo-se 1,18 % de CO2 absorvido por solução de MEA e 1,00 % por solução de DEA. / Due to the need to quantify carbamates from the CO2 gas chemical absorption process by monoethanolamine (MEA) and diethanolamine (DEA), analytical curves by IR spectroscopy were obtained with the aim of quantifying MEA and DEA carbamates and MEA, DEA and methyldiethanolamine (MDEA) in pure solutions and mixtures. The analytical procedure considered the preparation of standard samples constituents of the calibration curves and their quantification using reference instrumental techniques potentiometric titration, gravimetry and GC-FID. The standard samples of pure amines were quantified by potentiometric titration, getting the accurate detection of the equivalence point. The compositions of the analytical standards of the mixtures were established according to a triangular diagram for mixtures and the content of each component was determined by gravimetry and GC-FID. The carbamate hidrolysis and its thermal degradation were factors that limited the use of potentiometric titration, HPLCMS/ MS and GC-FID as reference techniques in their quantitation. These restrictions, added to the fact of not having commercial availability of these carbamates, led the use of 1H NMR spectroscopy for the quantitative determination. The calibration curves resulted in an excellent adjustment of the expected values related to the reference values and maximum error of prediction of 0.594 %. Two chemical absorption processes of CO2 gas were performed in semi-pilot scale and the obtained results were of 1.02 % and 0.98 % of absorbed CO2 by MEA and DEA solutions, respectively. Both processes were simulated using Aspen Plus software, presenting 1.18 % of CO2 absorbed by MEA solution and 1.00 % by DEA solution.
124

Estudo das características modais de um modelo de aeronave em alumínio /

Oliveira Junior, Adelmo Fernandes de. January 2016 (has links)
Orientador: Mauro Hugo Mathias / Coorientador: Everaldo de Barros / Banca: José Elias Tomazini / Banca: Carlos D'Andrade Souto / Resumo: A análise modal experimental é uma das técnicas mais importantes na caracterização dinâmica de estruturas. No setor aeroespacial a analise modal experimental é conhecida como Ground Vibration Test (GVT). Na Força Aérea Brasileira, o órgão responsável para executar o GVT é o Laboratório de Ensaios de Vibração (LEVI) da Divisão de Integração e Ensaio (AIE) do Instituto de Aeronáutica e Espaço (IAE). Esta pesquisa foi realizada neste laboratório que possui as facilidades para a execução de GVT. O objetivo principal deste estudo foi aprimorar a metodologia de ensaio de análise modal aplicada a um modelo de aeronave em alumínio do tipo GARTEUR SM-AG-19. O estudo desenvolvido possibilita que em ensaios futuros os resultados sejam replicados, no intuito de avaliar a integridade do sistema de medição, levando em consideração aspectos da influência do torque na junta aparafusada entre a asa e a fuselagem. Para validar a metodologia os resultados obtidos neste estudo foram comparados com os resultados de dois estudos desenvolvidos no Brasil. A contribuição principal desta pesquisa é relacionada ao estudo do efeito da variação do torque na junta aparafusada entre a asa e a fuselagem sobre os parâmetros modais da estrutura / Abstract: The experimental modal analysis is one of the most important techniques in the dynamic characterization of structures. In the aerospace industry, the experimental modal analysis is known as Ground Vibration Test (GVT). In the Brazilian Air Force, the institution responsible for executing the GVT is the Laboratory of Vibration Testing (LEVI) of the Integration and Testing Division (AIE) of the Institute of Aeronautics and Space (IAE). This research was carried out on this laboratory that has the facilities to perform the GVT. The main objective of this study was to improve the modal analysis test methodology applied to an aluminium aircraft model named GARTEUR SM-AG-19. This study allows the results to be replicated in future tests in order to evaluate the integrity of the measurement system, taking into account aspects of the influence of the torque on the bolted joint between wing and fuselage. In order to validate the methodology the results obtained in this study were compared to the results of two studies developed in Brazil. The main contribution of this research is the study of the torque variation effect on the bolted joint between wing and fuselage on the modal parameters of the structure / Mestre
125

Calibração física do sistema fotométrico CBVRIj

Storchi-Bergmann, Thaisa January 1980 (has links)
Utilizando observações de 327 estrelas, na sua maioria gigantes de tipos espectrais G e K, tenta-se obter uma calibração empírica para o sistema fotométrico CBVRIj. Este é um sistema de banda larga, que permite observações de estrelas mesmo fora da Galáxia. / Observations of 327 stars, mostly giants of spectral types G and K, are used in the search of an empirical calibration to the CBVRIj photometric system. This is a wide band system, which allows observations of stars even out of the galaxy.
126

Implementação de um sistema de aquisição de dados da técnica de judô Osotogari utilizando dummy na realização do uchikomi /

Nagata, Eduardo Yoshinori. January 2015 (has links)
Orientador: Tamotsu Hirata / Banca: José Elias Tomazini / Banca: Marcelo Sampaio Martins / Banca: Cesar Ferreira Amorim / Banca: Luiz Heleno Moreira Duque / Resumo: O judô é um esporte muito praticado no mundo todo, sendo uma modalidade que exige boa condição física para a melhor performance. Para a execução dos golpes é necessária a coordenação das ações dos membros superiores e inferiores, assim como a força exercida pelos membros ser sincronizada para atingir eficiência no gesto motor. O presente estudo teve por objetivo construir um equipamento de avaliação de desempenho para verificar o comportamento dos sinais de força na execução da técnica de judô Osotogari no treinamento de uchikomi. O equipamento de avaliação de desempenho confeccionado com 4 células de carga que foram posicionados nos 4 contatos do uke (pessoa que recebe o golpe) no tori (pessoa que executa o golpe) ao realizar o golpe. O equipamento foi construído num dummy com uma célula de carga acoplada no peito esquerdo, outra célula de carga posicionada na parte posterior da coxa direita. O dummy foi vestido com um kimono adaptado, e nele foram colocados uma célula de carga na manga direita e outra célula de carga na gola esquerda. Participaram da pesquisa 12 sujeitos com dominância lateral direita, sendo 5 experientes e 7 iniciantes. Os sujeitos realizaram 1 série de 10 repetições do Osotogari. Verificou-se diferença significativa (p < 0,05) entre os sujeitos experientes e iniciantes nos valores de força da célula de manga e célula de gola. Os valores de força da célula da perna e célula do peito não apresentaram diferença significativa. Foi observado média correlação linear entre os valores de pico da força da célula de manga e de gola, que pode ser explicado pelo sincronismo temporal e ritmo que é empregado pelas duas mãos. Foi verificado que há um instante ideal para aplicar a força para se obter um melhor desempenho na execução do golpe. A utilização do dummy tem o intuito de suprir a ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Judo is a worldwide practiced sport which requires physical fitness for better performance. For the fulfilment of the techniques, it is necessary the coordination of lower and inferior limbs, as well as the synchronization of power delivered by the limbs to achieve efficiency on the gesture. The objective of the present study was to develop an equipment for the performance evaluation of the judo technique Osotogari during uchikomi training, through the behavior of strength signals. The device had 4 load cells placed on four locations of the uke's body (one who receives the technique) on the tori (one who performs the technique) while applying the technique. The device as built based on a dummy, with one load cell placed on the left side of the chest, other on the back side of the right thigh. The dummy was dressed in a adapted kimono, that received a load cell on the right sleeve and another one on the left side collar. 12 subjects of right side dominance took part on the survey, 7 of them were beginners and 5 were experienced. Each of these subjects performed 1 serie of 10 repetitions of Osotogari. A significant difference was observed between experienced subjects and beginners for the sleeve and the collar load cells data. In the other hand, no significant difference was observed on the chest and thigh load cells. Moderate linear correlation was observed between peak force data of the sleeve and collar load cells, which can be explained by the hands' temporal synchronization and rhythm. It was observed that there is an ideal moment to apply strength when performing the technique, in order to achieve better performance. The dummy is intended to meet the need for more practical performance analysis methods, contributing this way to the advance in athletes training / Doutor
127

Análise quantitativa de alcanolaminas e CO2 no processo de absorção química via espectroscopia no infravermelho / Quantitative analysis of alkanolamines and CO2 in chemical absorption process by infrared spectroscopy

Denise Trigilio Tavares 15 December 2015 (has links)
Em virtude da necessidade de se quantificar os carbamatos provenientes de processos de absorção química do gás CO2 por monoetanolamina (MEA) e dietanolamina (DEA), curvas analíticas por espectroscopia no infravermelho (IV) foram construídas visando à determinação do teor de carbamatos de MEA e DEA, além da quantificação de MEA, DEA e metildietanolamina (MDEA) em soluções puras e em misturas. O procedimento analítico compreendeu o preparo das amostras-padrão constituintes das curvas de calibração e suas quantificações com o emprego de técnicas instrumentais de referência titulação potenciométrica, pesagem e GC-FID. As amostras-padrão de aminas puras foram quantificadas por titulação potenciométrica, sendo possível a detecção exata do ponto de equivalência. As composições dos padrões analíticos de misturas foram estabelecidas segundo um diagrama triangular para misturas e o teor de cada componente foi determinado por gravimetria e GC-FID. Tanto a hidrólise quanto a degradação térmica dos carbamatos foram fatores que restringiram o emprego da titulação potenciométrica, HPLC-MS/MS e GC-FID como técnicas de referência em suas quantificações. Essas restrições, somadas ao fato de não haver disponibilidade comercial desses carbamatos, levaram ao uso da espectroscopia de RMN de 1H na determinação quantitativa. As curvas de calibração apresentaram ótimo ajuste dos valores preditos com relação aos de referência e erro máximo de predição de 0,594 %. Dois processos de absorção química do gás CO2 foram realizados em escala semipiloto e os resultados obtidos foram de 1,02 % e 0,98 % de CO2 absorvido por solução de MEA e DEA, respectivamente. Os mesmos processos foram simulados no software Aspen Plus, obtendo-se 1,18 % de CO2 absorvido por solução de MEA e 1,00 % por solução de DEA. / Due to the need to quantify carbamates from the CO2 gas chemical absorption process by monoethanolamine (MEA) and diethanolamine (DEA), analytical curves by IR spectroscopy were obtained with the aim of quantifying MEA and DEA carbamates and MEA, DEA and methyldiethanolamine (MDEA) in pure solutions and mixtures. The analytical procedure considered the preparation of standard samples constituents of the calibration curves and their quantification using reference instrumental techniques potentiometric titration, gravimetry and GC-FID. The standard samples of pure amines were quantified by potentiometric titration, getting the accurate detection of the equivalence point. The compositions of the analytical standards of the mixtures were established according to a triangular diagram for mixtures and the content of each component was determined by gravimetry and GC-FID. The carbamate hidrolysis and its thermal degradation were factors that limited the use of potentiometric titration, HPLCMS/ MS and GC-FID as reference techniques in their quantitation. These restrictions, added to the fact of not having commercial availability of these carbamates, led the use of 1H NMR spectroscopy for the quantitative determination. The calibration curves resulted in an excellent adjustment of the expected values related to the reference values and maximum error of prediction of 0.594 %. Two chemical absorption processes of CO2 gas were performed in semi-pilot scale and the obtained results were of 1.02 % and 0.98 % of absorbed CO2 by MEA and DEA solutions, respectively. Both processes were simulated using Aspen Plus software, presenting 1.18 % of CO2 absorbed by MEA solution and 1.00 % by DEA solution.
128

Uma contribuição ao desenvolvimento de sistemas baseados em visão estéreo para o auxílio a navegação de robôs móveis e veículos inteligentes / A contribution to the development of stereo vision based to aid the mobile robot navigation and intelligent vehicles

Leandro Carlos Fernandes 04 December 2014 (has links)
Esta tese visa apresentar uma contribuição ao desenvolvimento de sistemas computacionais, baseados principalmente em visão computacional, usados para o auxílio a navegação de robôs móveis e veículos inteligentes. Inicialmente, buscou-se apresentar uma proposição de uma arquitetura de um sistema computacional para veículos inteligente que permita a construção de sistemas que sirvam tanto para o apoio ao motorista, auxiliando-o em sua forma de condução, quanto para o controle autônomo, proporcionando maior segurança e autonomia do tráfego de veículos em meio urbano, em rodovias e inclusive no meio rural. Esta arquitetura vem sendo aperfeiçoada e validada junto as plataformas CaRINA I e CaRINA II (Carro Robótico Inteligente para Navegação Autônoma), que também foram alvo de desenvolvimentos e pesquisas junto a esta tese, permitindo também a experimentação prática dos conceitos propostos nesta tese. Neste contexto do desenvolvimento de veículos inteligentes e autônomos, o uso de sensores para a percepção 3D do ambiente possui um papel muito importante, permitindo o desvio de obstáculos e navegação autônoma, onde a adoção de sensores de menor custo tem sido buscada a m de viabilizar aplicações comerciais. As câmeras estéreo são dispositivos que se enquadram nestes requisitos de custo e percepção 3D, destacando-se como sendo o foco da proposta de um novo método automático de calibração apresentado nesta tese. O método proposto permite estimar os parâmetros extrínsecos de um sistema de câmeras estéreo através de um processo evolutivo que considera apenas a coerência e a qualidade de alguns elementos do cenário quanto ao mapa de profundidade. Esta proposta apresenta uma forma original de calibração que permite a um usuário, sem grandes conhecimentos sobre visão estéreo, ajustar o sistema de câmeras para novas configurações e necessidades. O sistema proposto foi testado com imagens reais, obtendo resultados bastante promissores, se comparado aos métodos tradicionais de calibração de câmeras estéreo que fazem uso de um processo interativo de estimação dos parâmetros através da apresentação e uso de um padrão xadrez. Este método apresenta-se como uma abordagem promissora para realizar a fusão dos dados de câmeras e sensores, permitindo o ajuste das matrizes de transformação (parâmetros extrínsecos do sistema), a m de obter uma referência única onde são representados e agrupados os dados vindos dos diferentes sensores. / This thesis aims to provide a contribution to computer systems development based on computer vision used to aid the navigation of mobile robots and intelligent vehicles. Initially, we propose a computer system architecture for intelligent vehicles where intention is to support both the driver, helping him in driving way; and the autonomous control, providing greater security and autonomy of vehicular traffic in urban areas, on highways and even in rural areas. This architecture has been validated and improved with CaRINA I and CaRINA II platforms development, which were also subject of this thesis and allowed the practical experimentation of concepts proposed. In context of intelligent autonomous vehicles, the use of sensors that provides a 3D environment perception has a very important role to enable obstacle avoidance and autonomous navigation. Therefor the adoption of lower cost sensors have been sought in order to facilitate commercial applications. The stereo cameras are devices that fit these both requirements (cost and 3D perception), standing out as focus of the proposal for a new automatic calibration method presented in this thesis. The proposed method allows to estimate the extrinsic parameters of a stereo camera system through an evolutionary process that considers only the consistency and the quality of some elements of the scenario as to the depth map. This proposal presents a unique form of calibration that allows a user without much knowledge of stereo vision, adjust the camera system for new settings and needs. The system was tested with real images, obtaining very promising results as compared to traditional methods of calibration of stereo cameras that use an iterative process of parameter estimation through the presentation and use of a checkerboard pattern. This method offers a promising approach to achieve the fusion of the data from cameras and sensors, allowing adjustment of transformation matrices (extrinsic system parameters) in order to obtain a single reference in which they are grouped together and represented the data from the different sensors.
129

Desenvolvimento de sistema computacional para planejamento e controle da manutenção do reator IEA-R1 / Development of a computational program to planning and control of the IEA-R1 reactor maintenance

Mauro Onofre Martins 29 May 2015 (has links)
A manutenção é uma atividade essencial em reatores nucleares. Os componentes de sistemas de segurança de uma instalação industrial devem ter uma baixa probabilidade de falha, especialmente se houver um elevado risco de acidentes que podem causar danos ambientais. Em instalações nucleares, a presença de sistemas de segurança são uma especificação técnica e uma exigência para a sua licença de funcionamento. De forma a gerenciar todo o fluxo de informações provenientes das manutenções do Reator IEA-R1 foi desenvolvido um sistema computacional, que além de planejar e controlar toda a manutenção mantém atualizados documentos e registros para salvaguardar a qualidade e garantir a segurança na operação do Reator IEA-R1. O sistema computacional possui níveis de acesso e apresenta relatórios detalhados de todas as manutenções previstas e executadas, e também um histórico individual de cada equipamento durante sua vida útil na instalação. O trabalho apresenta todas as etapas de desenvolvimento do sistema, sua descrição, compatibilidades, aplicação, vantagens e resultados obtidos experimentalmente. / Maintenance is an essential activity in nuclear reactors. The safety systems components of an industrial plant should have a low failure probability, especially in case of high risk of accidents with potential for environment damage. In nuclear facilities, the security systems are a technical specification and a requirement for license operation. In order to manage the IEA-R1 maintenance information flow, a computational program (software) was developed, to plan and control all the maintenance, update the documents and records to quality safeguard and ensure the safe reactor operation. The software has access levels and share detailed maintenance planned and implemented reports, and equipment reports, during its facility lifetime. This work presents all the stages of the software development, description, compatibilities, application, advantages and experimental results.
130

Análise quantitativa dos resultados dos testes de controle de qualidade em radioterapia / Quantitative analysis of results for quality assurance in radiotherapy

Bruno Martins Passaro 14 September 2011 (has links)
Os aceleradores lineares representam a mais importante, prática e versátil produtores de raios-X de alta energia em radioterapia. O comportamento funcional destes equipamentos pode variar devido a defeitos eletrônicos, falhas de componentes ou rupturas mecânicas, ou então podem variar devido ao deterioramento e envelhecimento de seus componentes. A manutenção da qualidade dos tratamentos depende essencialmente da estabilidade dos aceleradores e do controle de qualidade das instituições para monitorar desvios nos parâmetros do feixe. O objetivo deste trabalho consiste em avaliar e analisar a estabilidade do fator de calibração dos aceleradores lineares, bem como os demais parâmetros dosimétricos normalmente incluídos em um programa de controle de qualidade em radioterapia. A média dos fatores de calibração dos aceleradores para o período de aproximadamente quatro anos para os Clinacs 600C e 6EX foram (0,998 ± 0,012) e (0,996 ± 0,014), respectivamente. Para o Clinac 2100CD de 6 MV e 15 MV foi (1,008 ± 0,009) e (1,006 ± 0,010), respectivamente, em um período de aproximadamente quatro anos. Através de análises estatísticas nos três aceleradores lineares verificou-se que os coeficientes de variação dos fatores de calibração apresentaram valores inferiores a 2% o que mostra uma homogeneidade nos dados. Através do cálculo da distribuição normal dos fatores de calibração, verificou-se que para os Clinacs 600C e 2100CD, é esperada uma probabilidade de que em mais de 90% dos casos os valores estejam dentro dos limites aceitáveis segundo o protocolo TG-142, enquanto que para o Clinac 6EX é esperado em torno de 85% uma vez que esse acelerador apresentou diversas trocas de componentes. Os valores do TPR20,10 dos três aceleradores são praticamente constantes e dentro dos limites aceitáveis segundo o protocolo TG-142. Pode-se concluir que um estudo detalhado dos dados do fator de calibração dos aceleradores e do TPR20,10 a partir de um ponto de vista quantitativo, é extremamente útil em um programa de garantia de qualidade. / The linear accelerators represent the most important, practical and versatile source of ionizing radiation in radiotherapy. These functional characteristics influence the geometric and dosimetric accuracy of therapeutic doses applied to patients. The performance of this equipment may vary due to electronic defects, component failures or mechanical breakdowns, or may vary due to the deterioration and aging of components. Maintaining the quality of care depends on the stability of the accelerators and quality control of the institutions to monitor deviations in the parameters of the beam. The aim of this study is to assess and analyze the stability of the calibration factor of linear accelerators, as well as the other dosimetric parameters normally included in a program of quality control in radiotherapy. The average calibration factors of the accelerators for the period of approximately four years for the Clinac 600C and Clinac 6EX were (0,998 ± 0,012) and (0,996 ± 0,014), respectively. For the Clinac 2100CD 6 MV and 15 MV was (1,008 ± 0,009) and (1,006 ± 0,010), respectively, in a period of approximately four years. Statistical analysis of the three linear accelerators was found that the coefficient of variation of calibration factors had values below 2% which shows a consistency in the data. By calculating the normal distribution of calibration factors, we found that for the Clinac 600C and Clinac 2100CD, is an expected probability that more than 90% of cases the values are within acceptable limits according to the TG-142, while for the Clinac 6EX is expected around 85% since this had several exchanges of accelerator components. The values of TPR20,10 of three accelerators are practically constant and within acceptable limits according to the TG-142. It can be concluded that a detailed study of data from the calibration factor of the accelerators and TPR20,10 from a quantitative point of view, is extremely useful in a quality assurance program.

Page generated in 0.0937 seconds