• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 371
  • 6
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 389
  • 281
  • 268
  • 218
  • 100
  • 89
  • 86
  • 60
  • 55
  • 54
  • 50
  • 47
  • 41
  • 41
  • 38
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

[en] FLOW OF PSEUDO-PLASTIC LIQUID THROUGH CAPILLARY TUBES WITH THROAT / [pt] ESCOAMENTO DE LÍQUIDO PSEUDO-PLÁSTICO ATRAVÉS DE CAPILAR COM GARGANTA

JOAO EMIDIO LIMA DA SILVA JUNIOR 08 May 2008 (has links)
[pt] Devido às suas aplicações nas mais diversas áreas do conhecimento humano e em atividades vitais para o mundo moderno, como a prospecção e produção de petróleo, o escoamento de fluidos em meios porosos tem sido objeto de inúmeros estudos experimentais e teóricos. Por exemplo, na recuperação de campos de petróleo, depara-se com o desafio de prever o comportamento de fluidos a serem injetados na formação (gás, água ou águacom adição de polímero), com o objetivo de aumentar a pressão e otimizar a recuperação de óleo. A abordagem adequada desta questão, implica na necessidade de profundo conhecimento do meio poroso e do comportamento dos fluidos envolvidos, bem como na utilização de modelos experimentais e/ou teóricos que propiciem simulações desses processos com razoável fidelidade. Neste trabalho o trajeto do fluido entre os espaços vazios de um meio poroso é representado por um capilar com contração/expansão (garganta). A partir de relações geométricas convenientemente definidas, onde apenas um parâmetro varia, foram geradas oito diferentes geometrias de análise. Foram feitas simulações numéricas de fluido newtoniano e pseudo-plástico utilizando-se código CFD desenvolvido na PUC-Rio. São estabelecidas relações entre o escoamento em capilares com garganta e o escoamento em capilares equivalentes, com raio constante. São apresentadas e comparadas duas metodologias, determinando raios equivalentes analíticos e ajustados (Req an e Req aj). Para fluidos newtonianos, a aproximação é muito boa em todas as geometrias, sendo a maior diferença 6,2%. Para fluido power law a diferença também é satisfatória, embora maior. / [en] Due to its application on a large number of fields and activities which are vital for the modern world, being oil prospection one of them, the flow of fluids on porous media have been studied in many experimental works and theoretical pieces. For instance, regarding the recovery of oil fields, it is challenging to predict the behavior of fluids that will be injected on the formation (gas, water or water added with polymer), with the objective to increase the pressure and optimize the oil recuperation. To approach this matter adequately a deep knowledge of the porous media and the behavior of the fluid in question are required, in addition to the use of the experimental and/or theorical models which provide simulations of this process with reasonable fidelity. On this experiment the path of the fluid through the empty spaces of a porous medium is represented by a capillary with contraction/expansion (throat). Starting with the conveniently defined geometrical relations where only one parameter varies, we generated eight different analysis geometries. Numerical simulations of the Newtonian and Pseudo-Plastic fluids were done using the CFD code developed at PUC-Rio. Relationships were established between the flow on capillaries with throat and equivalent capillaries, with constant radius. Two methodologies are presented and compared, determining equivalent analytical radius and adjusted (Req an e Req aj). For the case of Newtonians fluids, the approximation works very well on all geometries, and the largest difference is 6.2%. Although larger, the approximation still works in a satisfactory manner when dealing with Power Law fluids.
72

[en] ELONGATIONAL BEHAVIOR OF COMPOSITE THERMOPLASTIC MATERIALS / [pt] COMPORTAMENTO ELONGACIONAL DOS MATERIAIS TERMOPLÁSTICOS COMPÓSITOS

ALINE AMARAL QUINTELLA ABDU 08 April 2008 (has links)
[pt] Os materiais termoplásticos compósitos, tais como o polipropileno reforçado com fibras de vidro curtas, são usados cada vez mais em diversos setores industriais. O reforço da fibra de vidro é uma forma utilizada para melhorar as propriedades mecânicas dos termoplásticos, devido ao elevado módulo das fibras e à melhor adesão entre as fibras e a matriz polimérica. No entanto, há poucas informações referentes às propriedades desses fluidos na literatura. No presente trabalho, um estudo das propriedades cisalhantes e elongacionais do polipropileno reforçado com fibras de vidros curtas é apresentado. As viscosidades cisalhantes e elongacionais foram obtidas em um reômetro capilar através da medição da queda de pressão na entrada convergente de um capilar axissimétrico. Utilizaram-se duas geometrias diferentes na entrada do capilar, para a obtenção dos dados experimentais: as geometrias semi-hiperbólica convergente e cônica convergente. Neste último, a viscosidade elongacional foi obtida a partir da queda de pressão na entrada, utilizando as análises de Cogswell e Binding. Simulações numéricas foram realizadas com o objetivo de investigar o comportamento do polipropileno em um processo de extrusão. As equações de conservação de massa e quantidade de movimento foram resolvidas utilizando o método dos elementos finitos a partir do programa comercial Polyflow (Ansys). Para modelar o comportamento da mecânico viscoelástico do polipropileno foram utilizados os modelos de Maxwell, Oldroyd-B e Phan-Thien Tanner (PTT), no entanto a comparação entre os resultados numéricos e os experimentais obtidos no reômetro capilar não apresentaram concordância satisfatória. / [en] Composite thermoplastic materials, like glass fiber reforced polypropropylene, are used increasingly in several industries. In particular, glass fiber reinforcement is used to improve the mechanical properties of thermoplastics, due to the high fiber modulous and to the better adesion between the fibers and the polymeric matrix. However, few data of material properties of these fluids are avaiable in the literature. In this work, a study of shear and elongational properties of a commercial short glass fiber reinforced polypropylene is presented. The shear and elongational viscosities were obtained using the pressure drop measured at a capillary rheometer, with axisymmetric converging dies. Two different die geometries were used: semihyperbolically convergent dies and conical convergent dies. In the last case, the elongational viscosity was obtained using the Cogswell and Binding analysis. Numerical simulations were also performed, to investigate the flow field through the extrusion die process, and to evaluate the pressure drop and elongational viscosity. The conservation equations of mass and momentum were solved via the finite element method, using the commercial program POLYFLOW (Ansys). The Maxwell, Oldroyd B and Phan Thien-Tanner (PTT) constitutive equations were used to model the viscoelastic mechanical behavior of Polypropylene, but the comparison between numerical results and experimental data obtained from the capillary rheometer did not show good agreement.
73

Avaliação da eficiência da eletroforese capilar como técnica analítica na prospecção de metabólitos de esteróides em extratos fecais de onça-pintada (Panthera onca) / Evaluation of the efficiency of the capillary electrophoresis as analytical technique in the research of steroids metabolites in jaguar fecal extracts (Panthera onca)

Guião-Leite, Flaviana Lima 12 June 2006 (has links)
O objetivo deste trabalho foi desenvolver um protocolo de extração hormonal à partir de fezes de onça-pintada (Panthera onca) e validar uma metodologia de análise destes extratos por eletroforese capilar, verificando a eficiência analítica desta técnica no estudo dos metabólitos de esteróides sexuais em fezes, com o intuito de utilização futura desta metodologia na rotina dos laboratórios de endocrinologia. Foram testados sete tratamentos para as amostras de fezes liofilizadas: quatro protocolos de extração em diferentes solventes, um de hidrólise ácida e dois protocolos de extração em fase sólida (SPE). O protocolo de extração em acetonitrila foi satisfatório como pré-tratamento da amostra e aliado à SPE C-18 apresentou bons resultados no que diz respeito à sensibilidade, precisão, recuperação e tempo de análise. Com base nos resultados obtidos, a eletroforese capilar pode ser considerada uma ótima alternativa para a prospecção de metabólitos de hormônios, podendo ser utilizada em análises de rotina nos laboratórios de endocrinologia animal, sobretudo naqueles que se dedicam às metodologias não-invasivas de avaliação da função reprodutiva em animais selvagens. / The objective of this work was to develop a protocol of hormonal extraction from jaguar feces (Panthera onca) and validate a methodology of analysis of these extracts with capillary electrophoresis, verifying the analytical efficiency of this technique in the study of the steroids metabolites in feces, with the objective of future use of this methodology in the routine of the endocrinology laboratories. Seven treatments were tested for the samples: four extraction protocols in different solvents, one of acid hydrolysis and two extraction protocols in solid phase (SPE). The extraction protocol in acetonitrila was satisfactory as pre-treatment of the samples and ally to SPE C-18, it presented good results with respect to the sensibility, precision, recovery and time of analysis. Based on the obtained results, the capillary electrophoresis can be considered a great alternative for the research of metabolites of hormones, it could also be used in routine analyses in the endocrinology laboratories, mainly in those that are devoted to the non-invasive evaluation methodologies of the reproductive function in wild animals.
74

Avaliação de fungos na obtenção do metabólito quiral e ativo 9-hidroxirisperidona (paliperidona) e análise por eletroforese capilar / Evaluation of fungi to obtain the chiral and active metabolite 9- hydroxyrisperidone (paliperidone) and analysis by capillary electrophoresis

Jesus, Liana Inara de 09 May 2013 (has links)
A risperidona (RISP) é um fármaco neuroléptico que após sua administração oral é metabolizado resultando em dois metabólitos quirais, a 7-hidroxirisperidona (7- RispOH) e a 9-hidroxirisperidona (9-RispOH). A 9-RispOH é o metabólito majoritário da risperidona a qual é comercializada na forma de racemato com o nome de paliperidona. Esse projeto teve como finalidade avaliar a capacidade dos fungos endofíticos Penicillium crustosum (VR4), Chaetomium globusum (VR10), Aspergillus fumigatus (VR12), Papulaspora immersa Hotson (SS13), Nigrospora sphaerica (Sacc.) E.W. Mason (SS67) e Glomerella cingulata (VA1) e do fungo de solo Mucor rouxii em biotransformar a risperidona em seu metabólito ativo 9-RispOH enantiosseletivamente. Foi objeto de estudo também a otimização do processo de biotransformação através do emprego de diferentes meios de cultura (Czapek, Czapek Dox e Koch`s K1) para o cultivo dos fungos utilizados no estudo. O método escolhido para a separação da risperidona e seus metabólitos quirais foi a eletroforese capilar (CE). As separações eletroforéticas dos analitos foram realizadas empregando um capilar de sílica fundida de 40 cm de comprimento e 75 ?m de diâmetro interno, uma solução tampão fosfato de sódio 100 mmol L-1 pH 3,0 contendo CD-?-sulfatada 2,0% (p/v) e carboximetil-?-CD 0,5% (p/v) como seletores quirais. Todos os experimentos no CE foram realizados no modo reverso aplicando uma tensão de -10kV. As amostras foram injetadas aplicando uma pressão 0,5 psi por 8 s. O capilar e as amostras permaneceram na temperatura de 20oC. Para a extração dos analitos do meio de cultura foi utilizado a microextração em fase líquida empregando membranas cilíndricas ocas (HF-LPME). A técnica de preparação de amostra foi realizada no modo de três fases utilizando uma fibra de polipropileno impregnada com n-octanol e preenchida com uma solução de ácido clorídrico 100 mmol L-1 pH 3,0. A fibra foi mergulhada na amostra tamponada com uma solução de fosfato de potássio dibásico 500 mmol L-1 pH 12,0. O método foi validado de acordo com os parâmetros estabelecidos pela ANVISA (Agência Nacional de Vigilância Sanitária) para análise de fármacos em material biológico avaliando os seguintes parâmetros: seletividade, linearidade, precisão, exatidão, limite de quantificação e estabilidade. Todos os parâmetros avaliados ficaram dentro dos limites estabelecidos pela ANVISA. Entre os fungos avaliados, apenas o Mucor rouxii foi capaz de biotransformar a risperidona em seu metabólito ativo e quiral 9-RispOH. Nas condições empregadas a razão enantiomérica foi de 79,6%. / Risperidone (RISP) is a neuroleptic drug which after oral administration is metabolized into two chiral metabolites, 7-hydroxyrisperidone (7-RispOH) and 9- hydroxyrisperidone (9-RispOH). 9-RispOH is the major metabolite and it is commercialized under the generic name paliperidone. The objective of this project was to evaluate the capability of the endophytic fungi Penicillium crustosum (VR4), Chaetomium globusum (VR10), Aspergillus fumigatus (VR12), Papulaspora immersa Hotson (SS13), Nigrospora sphaerica (Sacc.) E.W. Mason (SS67) and Glomerella cingulata (VA1) and the soil fungus Mucor rouxii to biotransform risperidone into its chiral and active metabolite 9-RispOH, enantioselectively. In addition, it was also optimized the biotransformation process through the use of different culture medium (Czapek, Czapek Dox and Koch`s K1). The chiral analysis was performed by capillary electrophoresis (CE). The electrophoretic separation of the analytes was accomplished in a silica capillary with 40 cm of length and 75 ?m of internal diameter. The background electrolyte was a sodium phosphate 100 mmol L-1 pH 3.0 plus 2.0% (w/v) sulfated-?-CD and 0.5% (w/v) carboxymethyl-?-CD. All experiment on CE was performed in reverse mode by applying a voltage of -10 KV. The samples were injected hydrodynamically by applying a pressure of 0.5 psi for 8 s. The temperature of analysis was 20oC. For the extraction of the analytes from the culture medium it was employed the hollow fiber liquid-phase microextraction (HF-LPME). The extraction conditions were: n-octanol as organic solvent and a hydrochloridric acid solution of 100 mm L-1 pH 3.0. The pH of the sample was controlled by the addition of potassium phosphate buffer 500 mmol L-1 pH 12.0. The method was validated according to ANVISA guidelines (Agência Nacional de Vigilância Sanitária) for the analysis of drugs in biological fluids. The following parameters were evaluated: selectivity, linearity, precision, accuracy, limit of quantification and stability. All parameters were in agreement with the established limits by ANVISA. From all the evaluate fungi only Mucor rouxii was able to biotransform risperidone into its chiral and active metabolite 9-RispOH. In the conditions used in these project the enantiomeric ratio was 79.6%.
75

\"Desenvolvimento de novos sensores a partir de CD-Rs para análise voltametrica e de métodos de eletroforese capilar para monitoramento de íons em águas\" / Development of new sensors from compact disc for voltammetric analysis and electrophoresis methods for monitoring of ions in water

Richter, Eduardo Mathias 10 December 2004 (has links)
Neste trabalho descreve-se o desenvolvimento de metodologias para análise de metais pesados em águas de abastecimento (sistema Guarapiranga) e em água de chuva por métodos voltamétricos, a quantificação de cátions e ânions por eletroforese capilar com detecção condutométrica sem contato (EC-DCC), a construção de eletrodos de prata a partir de CD-Rs e sua aplicação para medidas potenciométricas, amperométricas e voltamétricas, a confecção de microeletrodos de ouro explorando técnicas de micro-fabricação com toner e sua aplicação como detector amperométrico em eletroforese capilar e o uso de máscaras de toner para construção de redes de microeletrodos de ouro, platina e carbono. Para o desenvolvimento de metodologia para monitorar chumbo, cobre e mercúrio em águas de abastecimento e em água de chuva, enfatizou-se a utilização de dispositivos semidescartáveis de ouro construídos a partir de CD-Rs utilizando técnicas eletroanalíticas de redissolução. O limite de detecção para 300 s de pré-concentração foi calculado em 80, 90 e 100 ng L-1 para Pb2+, Cu2+ e Hg2+, respectivamente. O volume mínimo de amostra necessário para esta análise é de 0,5 mL. Para analisar estes metais em amostras de águas coletadas do sistema Guarapiranga, foi implementado um método alternativo simples e de baixo custo para eliminação da matéria orgânica presente nestas amostras. Este método permite o pré-tratamento de um grande número de amostras simultaneamente. Em adição à quantificação de metais pesados, ao longo deste trabalho também foi otimizada uma metodologia para o monitoramento de vários outros íons (Cl-, NO3-, SO42-, CH3COO-, F-, PO43-, NH4+, K+, Na+, Ca2+, Mg2+ e Li+) em águas do sistema Guarapiranga utilizando equipamento de eletroforese capilar com detecção condutométrica sem contato (EC-DCC) construído no laboratório. O limite de detecção para estes íons foi calculado em 0,23, 0,43, 0,50, 4,26, 0,75, 1,00, 0,09, 0,18, 0,19, 0,20, 0,19 e 0,23 mg L-1, respectivamente. Além da utilização de eletrodos de ouro, ao longo desta tese também foi desenvolvida metodologia para a construção de sensores a partir de CD-Rs de prata. São discutidas as diferentes etapas envolvidas na elaboração destes dispositivos, é apresentada a sua caracterização e são mostrados os resultados obtidos por voltametria de redissolução para análise de chumbo, por amperometria/FIA para análise de cianeto e por potenciometria/FIA para análise de cloreto. A aplicação de técnicas de micro-fabricação com toner para desenvolver detectores amperométricos de ouro para eletroforese capilar foi outro assunto estudado. Estes sensores foram acoplados a um sistema de eletroforese capilar utilizando uma célula do tipo \"wall-jet\". A potencialidade deste tipo de detecção em eletroforese capilar foi demonstrada com a análise simultânea de iodeto, ácido ascórbico, dipirona e paracetamol. O limite de detecção para estes íons foi calculado em 0,1, 0,5, 3,1 e 1,1 µmol L-1, respectivamente. O uso de máscaras de toner para construir redes de microeletrodos de ouro, platina e carbono é outro tópico apresentado nesta tese. Informações detalhadas sobre as etapas e parâmetros envolvidos na construção deste tipo de sensor são apresentadas. O desempenho, assim como algumas características peculiares destes dispositivos são demonstradas através do uso de sistemas químicos conhecidos e os resultados obtidos comparados com os de um eletrodo convencional. / This study describe the development of methodologies for the analysis of heavy metals in drinking water supply (Guarapiranga system) and in rain water by using voltammetric methods, for the quantification of cations and anions by capillary electrophoresis using contactless conductometric detection (CE-CCD), the construction of silver electrodes utilizing recordable CDs and its application for potentiometric, amperometric and voltammetric analysis, the confection of microelectrodes utilizing microfabrication techniques with toner and its application as electrochemical detector in capillary electrophoresis and the utilization of toner masks to construct gold, platinum and carbon microelectrodes arrays. In the development of methodologies for lead, copper and mercury monitoring for natural waters and in rain water, was emphasized the utilization of semi-disposable gold electrodes constructed from recordable CDs, utilizing stripping analysis techniques. The detection limit utilizing 300 s pre-concentration time was calculated as 80, 90 and 100 ng L-1 for Pb2+, Cu2+ e Hg2+, respectively. The minimum sample volume for each analysis is 0.5 mL. For the analysis of these metals in waters samples collected in the Guarapiranga dam, a simple and alternative low cost method to eliminate the organic mater present in these samples was implemented. This method permits the pre-treatment of many samples simultaneously. In addition to the quantification of heavy metals, in the course of this work, the methodology for monitoring many other ions (Cl-, NO3-, SO42-, CH3COO-, F-, PO43-, NH4+, K+, Na+, Ca2+, Mg2+ e Li+) in the waters from Guarapiranga dam utilizing capillary electrophoresis with contactless conductometric detection (CE-CCD), an instrument constructed in the laboratory was also optimized. The detection limit for these ions was calculated as 0.23, 0.43, 0.50, 4.26, 0.75, 1.00, 0.09, 0.18, 0.19, 0.20, 0.19 e 0.23 mg L-1, respectively. Apart from the utilization of gold electrodes, on this work, we also developed a new methodology for the construction of sensors starting from silver CD-Rs. The different steps involved in the manufacture of these devices are discussed, its characterization is presented and the results obtained utilizing voltammetry for lead analysis, FIA/amperometry for the analysis of cyanide and FIA/potentiometry for the analysis of chloride. The utilization of microfabrication techniques with toner to develop amperometric gold detectors for capillary electrophoresis applications was another subject investigated. These sensors were coupled a capillary electrophoresis system using a wall-jet type cell. The potentiality of this type of detection for capillary electrophoresis was demonstrated for the simultaneous analysis of iodide, ascorbic acid, dipyrone and paracetamol. The detection limit for these ions was calculated as 0.1, 0.5, 3.1 and 1.1 µmol L-1, respectively. The utilization of masks made with toner to construct arrays of gold, platinum and carbon microelectrodes is another topic presented in this thesis. Detailed information about the steps and factors involved in the construction of this kind of sensor are presented. The performance as well as some peculiar characteristics of these devices are demonstrated utilizing well know chemical systems and the results obtained compared to the ones of a conventional electrode.
76

Investigação de modos de extração aplicados a plantas de uso fitoterápico e tópico / Investigation of extraction modes applied to plant of phytopharmaceutical and topic use

Fujiya, Neide Mitsue 12 July 2006 (has links)
O interesse de plantas, do ponto de vista medicinal e cosmetológico, tem levado a necessidade de eficientes métodos de extração. A preparação da amostra é uma das mais importantes fases no desenvolvimento de uma metodologia analítica em preparações herbais. O presente trabalho teve como objetivo propor metodologias alternativas para a análise de metabólitos vegetais em produtos naturais, com ênfase em procedimentos de extração. As seguintes plantas foram avaliadas: soja (Glycine Max, Fabaceae), capsicum (Capsicum anuum, Solanaceae), camomila (Matricaria chamomilla, Compositae), guaraná (Paullinia cupana, Sapidaceae) e erva mate (Ilex paraguariensis, Aquifoliaceae). As principais classes de metabólitos vegetais estudadas foram os compostos fenólicos e metilxantinas, sendo utilizada a eletroforese capilar, como técnica de análise, em solução livre e em meio micelar. A otimização da metodologia de extração isoflavonas da soja, em cápsulas farmacêuticas, incluiu o uso de diferentes solventes, o tempo de extração, bem como a escolha do melhor solvente para a dissolução dos analitos para posterior injeção. A identificação tentativa de grupos derivados de malonil foi obtida a partir dos espectros de UV, tempo de migração e por hidrólise da amostra. Um estudo da composição de diferentes metabólitos primários e secundários da folha de soja, a saber: flavonóides, ácidos orgânicos, açúcares, cátions, ânions e ácidos graxos livres, foi realizado por variadas formas de extrações. Para o capsicum explorou-se a extração de capsaicinas por dispersão de matriz em fase sólida (MSPD). Os sorventes testados foram florisil, C-18 e sílica, sendo avaliados diferentes solventes para eluição. Um estudo de otimização da extração de cafeína em amostras de guaraná em pó foi realizado, utilizando-se, como referência, um extrato obtido em Soxhlet. Os polifenóis da camomila foram extraídos em ultrassom em diferentes tempos e temperaturas, comparada a análise por maceração e processador industrial, utilizando como extrator, o meio hidroglicólico. / The interest for plants of medicinal and cosmetic application demands methods with efficient extraction. Sample preparation is one of most important steps in the development of an analytic methodology in herbal preparation. The present work proposes methodologies for the analysis of the secondary metabolites in natural products, with emphasis in extraction procedures. The following plants were evaluated: soy (Glycine max), capsicum (Capsicum anuum), chamomile (Matricaria chamomilla), guaraná (Paullinia cupana), mate (Ilex paraguariensis) by the use of capillary electrophoresis. The first proposed method was applied to the determination of isoflavones in soy germ capsules from four different pharmaceutical laboratories. Peak assignment of unknown isoflavones in certain samples was assisted by hydrolysis procedures, migration behavior and UV spectra comparison. A study of the composition of metabolites and nutrients as flavonoids, organic acids, carbohydrates, cations, anions and fatty acids were evaluated in soy leaf. An easy, rapid method of extraction was performed for capsicnoids in Capsicum anuum by Matrix Solid Phase Dispersion (MSPD). Different solid phases C18, silica and florisil were tested. To guaraná different methodologies of extraction were tested (ultrasound, turrax) compared to exhaustive Soxhlet extract. The influence of operating parameters (temperature, time) on the extraction efficiency of chamomile by ultrasound was studied, compared extract by maceration and processing. The mixture of water and glycol was used.
77

Desenvolvimento de método analítico para determinação de fármacos veterinários por eletroforese capilar em ração para peixes / Development of analytical method for determination of veterinary drugs by capillary electrophoresis in fish feed

Lourenço, Luciana Pereira 12 June 2017 (has links)
A piscicultura vem se destacando no âmbito nacional, uma vez que o Brasil apresenta uma significante disponibilidade de recursos hídricos e condições geográficas e climáticas favoráveis, que permitem a criação de espécies exóticas e nativas. Devido ao intuito comercial e financeiro, os produtores utilizam o sistema de produção em cativeiro, que constitui em um ambiente favorável à disseminação de doenças, devido à maior densidade populacional dos animais, com o agravante de que o ambiente aquático propicia a proliferação de doenças infecciosas, Desta forma, o uso de medicamentos veterinários constitui-se num recurso importante para amenizar e/ou solucionar este problema, com destaque ao emprego de antimicrobianos da classe das quinolonas e sulfonamidas, por exemplo. A principal via de administração desses medicamentos é por ingestão oral através da ração. Portanto, a incorporação de fármacos na ração é um aspecto crítico e de grande importância quando se visa a garantia da dose de tratamento dos animais, bem como, os riscos relacionados à contaminação ambiental decorrentes de eventual lixiviação dos fármacos da ração para a água. Frente a isso, métodos analíticos voltados para a quantificação de fármacos na ração são imprescindíveis. Diante da vantagem de se contar com um método analítico versátil, capaz de ser aplicado à determinação simultânea de diferentes fármacos, o emprego da eletroforese capilar constitui numa promissora alternativa. Assim, este trabalho teve como objetivo desenvolver e validar um método para análise de seis quinolonas (ciprofloxacino, difloxacino, ofloxacino, ácido oxolínico, flumequina e enrofloxacino) e quatro sulfonamidas (sulfametazina, sulfadimetoxina, sulfametoxazol e sulfatiazol) simultaneamente por eletroforese capilar. Para isso, foi utilizado um capilar de sílica fundida, de 50 cm de comprimento efetivo e 75 ?m de diâmetro interno e eletrólito de corrida composto por uma solução de borato de sódio na concentração de 40 mmol L-1, 15% de metanol e pH 8,5, corrente de 60 ?A, temperatura de 35 °C e detecção em 255 nm. Nessas condições, houve a separação dos dez fármacos em menos de 20 minutos. Os parâmetros de desempenho analítico, linearidade, precisão, exatidão, limite de quantificação, seletividade e robustez foram avaliados e estão de acordo com os requisitos preconizados pelos guias oficiais. O método foi aplicado para quantificar os fármacos na ração após a incorporação e no estudo de lixiviação dos fármacos. Após 10 minutos de exposição na água, houve uma perda significativa de CIPRO (11%) e MTZ (16%), correspondendo a 1,650 mg g-1/peixe/dia e 2,400 mg g-1/peixe/dia, respectivamente. Assim, a lixiviação mostrou ser um fator que deve ser considerado na terapêutica dos animais na piscicultura, uma vez que pode contribuir para ineficiência do tratamento, resistência bacteriana e prejudicar a qualidade da água. / Fish farming has been prominent at the national level, since Brazil has a significant availability of water resources and favorable geographical and climatic conditions that allow the creation of exotic and native species. Due to commercial and financial purposes, producers use the captive production system, which is an environment conducive to the spread of diseases, due to the greater population density of the animals, with the aggravating circumstance that the aquatic environment leads to the proliferation of infectious diseases. Thus, one of the technologies used to solve this problem is the use of veterinary drugs, in which antimicrobials of the quinolones and sulphonamides class. The main route of administration of these drugs is by oral ingestion through feed. The incorporation of drugs in feed is a critical aspect and of great importance when it comes to a guarantee of the dose of treatment of the animals, as well as the risks related to environmental contamination resulting from leaching of the drugs from the feed to a water. Therefore, analytical methods for the quantification of drugs in feed are essential. Given the advantage of having a versatile analytical method capable of being applied to the simultaneous determination of different drugs, the use of capillary electrophoresis constitutes a promising alternative. In this context, the aim of this study was to develop and validate a method for the analysis of six quinolones (ciprofloxacin, difloxacin, ofloxacin, oxolinic acid, flumequine and enrofloxacin) and four sulfonamides (sulfamethazine, sulfadethoxine, sulfamethoxazole and sulfathiazole) simultaneously by capillary electrophoresis. For this, a fused silica capillary of 50 cm in effective length and 75 ?m internal diameter and running electrolyte composed of a sodium borate solution in the concentration of 35 mmol L-1, 15% of methanol and pH 8.5, current 60 ?A, temperature of 35 ° C and detection at 255 nm. Under final conditions, all analytes were separations in less than 20 minutes. The parameters of analytical performance, linearity, precision, accuracy, limit of quantification and detection, selectivity and robustness were evaluated and are in accordance with the requirements recommended by the official guides. The method was applied to quantify the drugs in the feed after the incorporation and in the study of the leaching of the drugs. After 10 minutes of exposure in the water, there was a significant loss of CIPRO (11%) and MTZ (16%), corresponding to 1,650 mg g-1/fish/day and 2,400 mg g-1/fish/day, respectively. Thus, leaching has been shown to be a factor that should be considered in the treatment of animals in fish farming, since it may contribute to inefficiency of treatment, bacterial resistance and impair water quality.
78

A eletroforese capilar para a separação das metalotioneínas da cianobactéria (Synechococcus PCC 7942) e de mamíferos / Capillary electrophoresis for the separation of cyanobacterial metallothionein (Synechococcus PCC 7942) and mammals

Vida, Ana Clara Felix 23 March 2011 (has links)
Metalotioneínas (MTs) são proteínas de baixa massa molecular, que tem como principal função a regulação dos níveis de metais nos organismos. A caracterização das MTs da cianobactéria Synechococcus PCC 7942 por eletroforese capilar foi feita em comparação com os padrões comerciais de MTs de rim de cavalo e de fígado de coelho. As MTs de mamíferos apresentam diferentes arranjos moleculares, classificadas em isoformas. Na aplicação da eletroforese capilar como metodologia analítica para a otimização da separação das isoformas existentes, foram investigados a influência da composição da solução eletrolítica, variações da voltagem, comprimento do capilar e diâmetro interno do capilar. Os perfis eletroforéticos das misturas das MTs purificadas a partir de rim de cavalo e fígado de coelho comparados com a de cianobactéria mostraram uma diferenciação no tempo de migração. Para a separação foram testados eletrólitos tais como fosfato, borato e TRIS-HCl, sendo que os melhores resultados foram obtidos com o tampão TRIS-HCl (70 mM, pH 8,2) com adição de 5% de metanol. A separação eletroforética foi testada em capilares de sílica fundida de 75 e 25 m d.i., comprimento de 40, 50 e 60 cm. As soluções das amostras em volume de 327 nL foram introduzidas por injeção hidrodinâmica. As diferenças de potencial testadas foram de 10, 15, 20 e 25 kV. As melhores condições de separação foram atingidas empregado TRIS-HCl com 5% metanol como solução eletrolítica, em capilar de 60 cm e diferença de potencial de 20 kV o que estabilizou a corrente de separação em 42 \'mü\'A. Os resultados mostraram que a eletroforese capilar mostrou-se eficiente para separação das MTs de mamifero e da Synechococcus devido às diferenças de carga e tamanho das moléculas / Metallothioneins (MTs) are low molecular weight proteins, which main functions are the regulation of metals levels in the body and detoxification. The capillary electrophoresis (CE) characterization of MT from Synechococcus cyanobacteria was attained by comparison with commercial standards of horse kidney and rabbit liver MTs. The influence of electrolyte, such as phosphate, borate and TRIS-HCl buffers on the separation performance were tested. Also, parameters such as voltage potential, capillary length and capillary inner diameter were investigated to attain optimized separation of mammal and Synechococcus MTs. The electrophoretic profiles of MTs revealed four abundant metallothionein isoforms for the horse kidney sample, one for rabbit liver MTII and two for cyanobacteria Synechococcus. The separation by CE of horse and cyanobacteria MTs mixtures differentiated two sets of signals, the first with four peaks corresponding to the horse sample and the last to Synechococcus. The mixture of rabbit liver MT and cyanobacteria MTs presented a first peak for rabbit MTII and a second for cyanobacteria. Tests were performed trying phosphate, borate and TRIS-HCl buffers, however the best results were attained with TRIS-HCl buffer (70 mM, pH 8.2) with addition of 5% methanol. Different capillary lengths of 40, 50 and 60 cm and two internal diameters of 75 and 25m were tested. Also, voltages of 10, 15, 20 and 25 kV were studied. The best experimental conditions were attained using a 60 cm long capillary, TRIS-HCl plus 5% methanol as electrolyte, the application of 20 kV which allowed maintaining a separation current of 42 \'mü\'A. Results demonstrated that capillary electrophoresis was efficient for separation of MTs of mammals from that of Synechoccocus due their differences on size to charge
79

Estudo longitudinal do padrão de vascularização do endoneuro do nervo vago de ratas da linhagem Wistar-Kyoto, em diferentes idades / Endoneural vessels vascular pattern on the vagus nerve of Wistar-Kyoto rats: A longitudinal study.

Schiavoni, Maria Cristina Lopes 06 May 2005 (has links)
Os nervos são abundantemente vascularizados em toda sua extensão, por intermédio de uma sucessão de vasos que, por suas consecutivas divisões e anastomoses no interior do nervo, formam uma rede vascular intraneural ininterrupta. Já está bem definido que o número de vasos nutrientes para um nervo em particular varia amplamente, não apenas de indivíduo para indivíduo, como também entre os dois lados do corpo. Nervos maiores não necessariamente recebem mais vasos que nervos menores. Os nervos podem percorrer distâncias consideráveis sem receber um vaso nutriente e o calibre desses vasos varia em amplos intervalos. Desse modo, o número e o tamanho dos vasos, juntamente com a sua distribuição no interior dos nervos estão sujeitos a uma grande variabilidade, não apenas em vários segmentos do mesmo nervo como também no mesmo nervo em diferentes sujeitos. Nosso objetivo, com o presente estudo foi o de realizar uma descrição do padrão longitudinal de vascularização do endoneuro e de avaliar a existência de uma possível correlação entre a área fascicular e a área endoneural ocupada pelos vasos capilares, no nervo vago de ratas da linhagem Wistar-Kyoto, em três diferentes fases da vida: 30, 180 e 360 dias de idade. Para tanto, três animais de cada grupo foram mortos e tiveram seus nervos vagos direitos preparados com técnicas histológicas de rotina para inclusão em resina epóxi. Secções transversais semifinas (0,4 µm) seriadas, obtidas a cada 100 µm de extensão longitudinal do nervo, até o esgotamento completo dos blocos, foram analisadas em nível de microscopia de luz. A morfometria dos fascículos e dos vasos capilares endoneurais, foi realizada com o auxílio de um sistema analisador de imagens computacional. A área fascicular média e a área média ocupada pelos capilares foram calculadas para cada segmento estudado (proximal, médio e distal) e comparadas entre segmentos (estudo longitudinal) e entre os grupos. A correlação entre a área fascicular total e a área endoneural ocupada pelos capilares foi estudada através de uma análise de regressão linear e do cálculo dos coeficientes de correlação. A porcentagem da área fascicular total ocupada pelos capilares endoneurais também foi calculada para cada segmento estudado e comparada entre segmentos e entre os grupos. Nossos resultados mostram que a área fascicular média de todos os segmentos estudados foi significativamente maior nos animais com 180 e 360 dias, comparados aos com 30 dias, em todos os segmentos estudados, acompanhando o ganho ponderal dos animais. Interessantemente, nos animais jovens (30 dias), houve uma tendência ao aumento dos valores dessa área no sentido longitudinal dos nervos, o que não foi observado nos animais mais velhos (180 e 360 dias). A área média dos capilares endoneurais aumentou no sentido longitudinal em todos os grupos estudados. Na comparação entre os grupos, houve uma estabilização da área fascicular média nos animais mais velhos enquanto que houve uma diminuição da área média dos capilares endoneurais com o avançar da idade. A porcentagem da área fascicular total ocupada pelos capilares aumentou, no sentido longitudinal, nos animais jovens (30 dias) e tendeu à estabilidade nos animais mais velhos (180 e 360 dias), havendo nítida diminuição progressiva dessa porcentagem com o avançar da idade. O estudo dos diâmetros dos capilares endoneurais mostrou que esses diâmetros variam amplamente, sem nenhum padrão específico entre segmentos de um mesmo grupo os entre os diferentes grupos. Nossos resultados também mostraram a existência de uma correlação positiva fraca (coeficientes de correlação com valores muito baixos) entre a área fascicular total e a área endoneural ocupada pelos capilares. Esses dados sugerem que a entrada dos capilares no nervo não é acompanhada de um aumento proporcional na área do fascículo. Os dados de diminuição da porcentagem da área fascicular total ocupada pelos capilares com o avançar da idade podem sugerir que os nervos de animais mais velhos possam ser mais susceptíveis aos processos isquêmicos. / Peripheral nerves are abundantly vascularised throughout their length by a succession of vessels which, by their repeated division and anastomosis within the nerve, for an unbroken intraneural vascular network. It is well defined that the number of nutrient vessels to any particular nerve varies greatly not only from subject to subject but also on the two sides of the body. Larger nerves do not necessarily receive more vessels than do smaller nerves. Nerves may run considerable distances without receiving a nutrient vessel and the caliber of the nutrient vessels fluctuates over wide limits. Thus, the number and size of these vessels, together with their distribution within the nerve, are subject to a wide range of variation, not only between various segments of a nerve but also in the same nerve in different specimens. In this way, our objectives were to study the longitudinal pattern of the endoneural vascularisation and, to determine the existence of a correlation between the fascicular total area and the endoneural area occupied by the capillary vessels on the vagus nerve of Wistar-Kyoto female rats, in three different ages. Three animas aged 30, 180 or 360 days were killed and their right vagus nerves were prepared for epoxy resin embedding and light microscopy study, by conventional techniques. Serial semihtin sections (0.4 µm), obtained every 100 µm of the vagus nerve longitudinal extension were measured with the aid of a computer software. The average fascicular area and the average area occupied by the endoneural capillary were obtained for each segment (proximal, medium and distal) and compared between segments (longitudinal study) and between ages. The correlation between the fascicular area and the area occupied by the endoneural capillary was accessed by linear regression analysis and correlation coefficient calculations. The percentage of the total fascicular area occupied by the capillaries was also calculated for each segment and compared between segments and between ages. Our results show that the average fascicular area, in all segments studied, was significantly larger in the older animals (180 and 360 days), compared to the younger (30 days). This was compatible with the weight gain of the animals. Interestingly, in the younger animals, there was a tendency of an increase in the average fascicular area from proximal to distal, and this was not observed in the older animals (180 and 360 days). The average area of the endoneural capillaries increased from proximal to distal in all groups studied. The analysis between groups showed a stabilization of the fascicular area in the older animals while the average capillary area got smaller with ageing. The percentage of the fascicular area occupied by the endoneural capillary vessels increased from proximal to distal in the younger animals (30 days) and got stable in the older (180 and 360 days). There was an obvious decrease in this percentage with ageing. The capillary vessels diameter study showed that this parameter varied considerably, without a established pattern between segments or groups. Our results also show the existence of a weak but positive correlation between the fascicular area and the area occupied by the endoneural capillary. This data suggests that the entrance of blood vessels to the endoneural space is not followed by an increase on the fascicular area. The result of a smaller percentage of the fascicular area occupied by the capillary vessels with ageing suggests that older animals may be more susceptible to nerve ischemia.
80

Desenvolvimento de sensores e de métodos analíticos para determinação de compostos de interesse farmacêutico / Development of sensors and analytical methods for determination of compounds of pharmaceutical relevance

Silva, Iranaldo Santos da 11 October 2013 (has links)
A crescente demanda por produtos farmacêuticos tem como consequência a necessidade de elaboração de novos procedimentos analíticos que, via de regra, apresentem características como: elevada frequência analítica, simplicidade, ausência de substâncias altamente tóxicas, e com baixo custo para o controle de qualidade dos fármacos lançados no mercado. Neste trabalho descreve-se o desenvolvimento de procedimentos para determinação de N-acetilcisteína (NAC), nimesulida (NMS), trimetoprima (TMP) e sulfametoxazol (SMX) em formulações farmacêuticas usando técnicas eletroanalíticas e métodos de separação. Na determinação da NAC foi usado um eletrodo de grafite pirolítico modificado com ftalocianina de cobalto (CoPc) em 0,1 mol L-1 de NaOH. Este sensor mostrou intensa catálise para NAC produzindo um aumento na corrente anódica de cerca de 700 vezes quando comparado com o eletrodo limpo. Um procedimento em FIA foi proposto usando este sensor, e a curva analítica foi linear no intervalo 5,0 × 10-5 a 1,0 × 10-3 mol L-1, com coeficiente de correlação maior que 0,999. O DPR de 1,1% (n = 13) foi obtido para uma solução contendo 5,0 × 10-4 mol L-1 de NAC. Além disso o método apresentou LD e LQ de 9,0 ×10-7 mol L-1 e 3,0 × 10-6 mol L-1, respectivamente. A determinação eletroanalítica de NMS foi conduzida em solução de 1,0 mol L-1 de NaOH usando eletrodo de carbono vítreo, meio em que não ocorre envenenamento da superfície do eletrodo. Desse modo, um método eletroanalítico usando voltametria de onda quadrada foi elaborado para análise de NMS. Nas condições ótimas de análise o método apresentou uma faixa linear no intervalo de 4,3 × 10-5 a 4,2 × 10-4 mol L-1, com limite de detecção de 3,2 × 10-6 mol L-1. A precisão do método foi avaliada em um mesmo dia de análise por sucessivas medidas voltamétricas (n = 10) em solução de hidróxido de sódio 1,0 mol L-1 contendo 1,0 × 10-4 mol L-1 de NMS, sem a necessidade de renovação da superfície do eletrodo. Os resultados para esta série de medidas foram avaliados e o DPR calculado foi somente 1,2%, indicando que nessas condições o eletrodo apresentou uma resposta estável além de não sofrer qualquer efeito de envenenamento. Para a determinação simultânea de TMP e SMX foi desenvolvido um método analítico empregando eletroforese capilar com detecção condutométrica sem contato (C4D). Usando uma solução 10 mmol L-1 lítio-fosfato (pH 7,1 ) como tampão de corrida, a faixa linear de trabalho obtida para ambos os analitos foi de 12,5 a 200 × 10-6 mol L-1 com R > 0,999. Nas condições de análise foram obtidos LDs de 1,1 × 10-6 mol L-1 para a TMP, e 3,3 × 10-6 mol L-1 para o SMX com um tempo total de análise de 2,6 minutos. / The growing demand for pharmaceutical products has created need for developing new analytical procedures that, as a rule, exhibit characteristics like, high sampling rate, simplicity, absence of highly toxic substances, and low cost for quality control of drugs launched in market. In this work, electroanalytical and capillary electrophoresis methods for determination of N-acetylcysteine (NAC), nimesulide (NMS), trimethoprim (TMP) and sulfamethoxazole (SMX) in pharmaceutical formulations were proposed. For NAC determinations a pyrolytic graphite electrode modified with CoPc in 0.1 mol L-1 NaOH was used. This new sensor showed to be catalytic for this compound producing an anodic current increase of 700 times when compared with bare electrode. A FIA procedure was proposed using this new sensor, and the method showed a linear response in a range of 5.0 × 10-5 to 1.0 × 10-3 mol L-1 with correlation coefficient better than 0.999. RSD of 1.1% (n = 13) was obtained for a solution containing 5.0 × 10-4 mol L-1 NAC. Furthermore the method presented DL and QL of 9.0 × 10-7 mol L-1 and 3.0 × 10-6 mol L-1, respectively. NMS electroanalytical determination was conducted in a 1.0 mol L-1 NaOH solution using a glassy carbon electrode. In strongly alkaline medium it was verified that NMS does not produce poisoning of the electrode surface. Thus an electroanalytical method using square wave voltammetry was proposed for analysis of NMS. In the optimal analysis conditions proposed method showed a linear response in a range of 4.3 × 10-5 to 4.2 × 10-4 mol L-1, with detection limit of 3.2 × 10-6 mol L-1. Accuracy of the method was evaluated on the same day by successive voltammetric measurements (n = 10) in a 1.0 mol L-1 sodium hydroxide solution containing 1.0 × 10-4 mol L-1 of NMS without the needing to renew electrode surface. Results for this series of measures were calculated and standard deviation was of only 1.2%, suggesting that in these conditions the electrode showed a stable response in addition to suffer no poisoning effects. For simultaneous determination of TMP and SMX an analytical method using capillary electrophoresis with contactless conductivity detection (C4D) was developed. Using a 10 mmol L-1 lithium-phosphate (pH 7.1) solution as running buffer, a linear response range for both analytes was obtained ranging through 12.5 to 200 × 10-6 mol L-1 with R> 0.999. Under these analysis conditions, DL of 1.1 × 10-6 mol L-1 for TMP, and 3.3 × 10-6 mol L-1 for SMX were obtained, with a total analysis time of only 2.6 minutes.

Page generated in 0.0444 seconds