• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 59
  • 1
  • Tagged with
  • 61
  • 61
  • 61
  • 38
  • 37
  • 30
  • 23
  • 16
  • 14
  • 12
  • 11
  • 11
  • 11
  • 10
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Adesividade e irritação cutânea do filme transparente gel de clorexidina em pacientes submetidos ao transplante de células tronco hematopoiéticas / Adhesiveness and skin rash related to the transparent film dressing with chlorhexidine gel applied to patients submitted to hematopoietic stem cell transplantation

Santos, Bruna Nogueira dos 21 September 2015 (has links)
O Transplante de Células-Tronco Hematopoéticas (TCTH) trata-se da substituição das Células-Tronco Hematopoéticas (CTH) doentes de um indivíduo por CTH normais com o objetivo de normalizar a hematopoese do receptor. O cateter venoso central (CVC) tornou-se indispensável para viabilizar tal terapêutica pela segurança na infusão das CTH e dos quimioterápicos. Para o TCTH são utilizados cateteres do tipo Hickman ou duplo lúmen, ambos de longa permanência. O curativo adesivo utilizado no sítio de inserção do cateter é essencial para a fixação do cateter, proteção contra agentes externos e prevenção de infecção. Há forte evidência clínica no uso do filme transparente gel de clorexidina (CHX) como uma alternativa no controle de infecções relacionadas ao cateter. A adesividade deste curativo confere-lhe uma possível permanência de até sete dias aderido à pele, o que evita repetidas aplicações e remoções do curativo, diminui a frequência na manipulação do cateter, a ocorrência de infecção e irritação cutânea local. Observa-se que a adesividade do curativo nem sempre permite a permanência por sete dias, sendo necessárias trocas não planejadas, podendo causar lesões à integridade cutânea. Neste estudo, objetivou-se avaliar a adesividade e a irritação cutânea do filme transparente gel de CHX aplicado no sítio de inserção do CVC por meio de um estudo transversal, prospectivo, realizado em um hospital público de ensino, no período de novembro de 2013 a junho de 2014, com crianças e adultos de ambos os sexos com doenças autoimunes ou onco-hematológicas submetidos ao TCTH. A amostra desta pesquisa foi constituída por 25 pacientes. Onze (44%) apresentaram irritação cutânea caracterizada por perda de pele de extensão <=0,5cm, perda de pele de extensão > 0,5cm, placa eritematosa e vesículas. Destes, seis tiveram necessidade de suspensão do uso do curativo. A pele fragilizada devido ao uso de agentes quimioterápicos pode aderir fortemente ao curativo adesivo, sendo desprendida com o mesmo quando este é removido. A perda da integridade cutânea com remoção da camada protetora da pele facilita a entrada de microrganismos aumentando a susceptibilidade a infecções em pacientes imunossuprimidos. Em 55,6% das avaliações foi observado desprendimento do curativo e a região da fenda foi onde mais ocorreu desprendimento (43,4%). Esta é uma região da margem do curativo, assim denominada por possuir uma abertura no adesivo onde são posicionadas as vias do cateter. Infere-se que devido à mobilidade do paciente e manuseio das vias do cateter, com o passar dos dias, essa região da borda do curativo apresenta maior desprendimento. Em 8,4% das observações havia bolha de ar no gel de clorexidina envolvendo o sítio de inserção do cateter. A bolha de ar no gel de clorexidina significa que este não está em contato com a pele do paciente o que é preocupante quando envolve o sítio de inserção do cateter, pois a CHX não está exercendo sua função antisséptica neste local, onde há possibilidade de migração extra- lúmen de microrganismos à corrente sanguínea / Hematopoietic stem cell transplantation (HSCT) involves the replacement of sick hematopoietic stem cells (HSC) from an individual with normal HSC, with the aim to restore the recipient\'s hematopoiesis. Central venous catheters (CVC) have become indispensable to make this therapy feasible due to the safety of infusion of the HSC and the chemotherapeutic agents. In HSCT, long-term Hickman or long-term double lumen catheters are used. The adhesive dressing used in the site of insertion of the catheter is essential for the catheter fixation, protection against external agents and prevention of infection. There is strong clinical evidence on the use of transparent film dressing with chlorhexidine gel (CHX) as an alternative in the control of catheter-related infections. The adhesiveness of this dressing allows it to be used up to seven days once it adheres to the skin, which avoids repeated dressing applications and removals, and reduces the frequency of catheter handling, the occurrence of infection, and local skin rash. However, as observed, the dressing adhesiveness does not always allow it to be used for seven days, and unplanned replacements may be needed, which can cause lesions to the skin integrity. The objective of this study was to evaluate the adhesiveness and skin rash related to the transparent film dressing with CHX gel applied at the site of insertion of the CVC by means of a cross-sectional, prospective study developed at a public teaching hospital, between November 2013 and June 2014, with children and adults of both genders with autoimmune or onco-hematological diseases who were submitted to HSCT. The sample comprised 25 patients. Eleven (44%) presented skin rash characterized by skin loss to an extension of <=0.5 cm, skin loss to an extension of > 0.5 cm, erythematous plaque and vesicles. Of these, six had to interrupt the use of the dressing. Frail skin due to the use of chemotherapeutic agents can adhere strongly to the adhesive dressing, coming off with the dressing at its removal. The loss of skin integrity with the removal of the skin\'s protective layer facilitates the entrance of microorganisms, increasing susceptibility to infections in immunosuppressed patients. In 55.6% of the evaluations, there was dressing detachment, and it was greater in the opening region (43.4%), which is a region in the dressing border with a break in the adhesive where the catheter is placed. Given the mobility of the patient and the handling of the catheter, over the days, this region of the dressing border presents greater detachment. In 8.4% of the observations there were air bubbles in the chlorhexidine gel involving the site of insertion of the catheter. Air bubbles in the chlorhexidine gel means that it is not in contact with the patient\'s skin, which is a cause of concern when the site of insertion of a catheter is involved, since CHX is not exerting its antiseptic function in this location, which can lead to extra-lumen migration of microorganisms to the bloodstream
22

Tipo de cateter central de inserção periférica e o motivo de sua remoção em uma coorte de neonatos / Type of peripherally inserted central catheter device and the reason for its removal in a cohort of neonates

Paiva, Eny Dórea 30 July 2012 (has links)
Introdução: Dispositivos de acesso venoso central tornaram-se vitais para a recuperação e sobrevivência dos neonatos e lactentes internados em Unidade de Terapia Intensiva Neonatal (UTIN). O cateter central de inserção periférica (CCIP) tem sido amplamente utilizado para atender às demandas terapêuticas dos neonatos e lactentes criticamente doentes e inovações nos dispositivos têm sido introduzidos e confeccionados com materiais biocompatíveis, como o silicone e o poliuretano, com único ou duplo lúmen. Objetivo: analisar a relação entre os tipos de cateteres centrais de inserção periférica (monolúmen de silicone e duplolúmen de poliuretano) instalados em neonatos e lactentes com os motivos de remoção do dispositivo. Método: coorte prospectiva, composta por neonatos e lactentes submetidos à instalação do CCIP, internados em UTIN de um hospital privado da cidade de São Paulo, no período de 1 de julho de 2010 a 30 de junho de 2011. Os neonatos e lactentes foram incluídos no estudo no momento da instalação do cateter e acompanhados durante a permanência do dispositivo. O projeto de pesquisa foi apreciado e aprovado pelo Comitê de Ética em Pesquisa da instituição, campo do estudo (Processo 219/2010). Resultados: foram analisados dados referentes a 270 CCIPs, 189 (70%) cateteres de monolúmen e 81 (30%) de duplolúmen. Os dois grupos de cateteres apresentaram características demográficas, clínicas, terapêuticas e relacionadas ao procedimento de inserção do cateter homogêneas, exceto para as variáveis: diagnóstico prévio de septicemia (p=0,0210) e ocorrência de dificuldade de progressão do cateter na instalação do mesmo (p=0,0296). Contudo, o valor de p para o teste de homogeneidade para razão de chances do diagnóstico prévio de septicemia e da dificuldade de progressão do cateter, não demonstrou diferença estatística, p=0,955 e p=0,400, respectivamente. A taxa de densidade de incidência (TI) de remoção não eletiva para o cateter monolúmen de silicone foi 34,8 em 1.000 cateteres-dia e a do cateter duplolúmen de poliuretano foi 32,8 em 1.000 cateteres-dia. Houve diferença estatística significante, p=0,0005, na média do tempo de permanência entre os dois tipos de cateteres, maior para o dispositivo de duplolúmen de poliuretano, 14 dias em relação ao dispositivo de monolúmen de silicone, 10 dias. Entretanto, não é possível afirmar que a taxa de densidade de incidência entre os cateteres se diferem entre si ao se estimar a curva de sobrevida pelo método Kaplan Meier dos cateteres com remoção não eletiva. As curvas de sobrevivência de ambos os cateteres se sobrepõem, entretanto o valor do logrank (0,45) indica que não há diferença estatística entre a incidência de remoção não eletiva entre os cateteres. Dessa forma, a hipótese conceitual defendida no presente estudo não pode ser confirmada. Conclusão: os resultados do estudo apontaram que não há diferença estatística significante nas taxas de incidência de remoção não eletiva entre os dois grupos de cateteres. Entretanto, o CCIP de duplolúmen de poliuretano apresentou média de tempo de permanência maior comparado ao dispositivo de monolúmen de silicone. / Introduction: Central venous access devices have become vital to the recovery and survival of newborns and infants hospitalized in the Neonatal Intensive Care Unit (NICU). The peripherally inserted central catheter (PICC) has been widely used to supply the therapeutic demands of critically ill newborns. Innovation in the PICC devices have been available, made from biocompatible materials such as silicone and polyurethane, with single or double lumen. Objective: To analyze the relationship between the type of peripherally inserted central catheter device (silicone single lumen or polyurethane double lumen) used in neonates and infants with the reasons for their removal. Method: prospective cohort study consisting of neonates and infants undergoing installation of PICC devices, admitted at the NICU of a private hospital in the city of São Paulo in the period from July 1st, 2010 to June 30, 2011. The neonates and infants were enrolled at the time of catheters installation and followed up until PICC device removal. The research project was examined and approved by the Institutional Research Ethics Boards where the study was carried out (Protocol number 219/2010). Results: Data from 270 PICC devices installed in 213 neonates, 189 (70%) silicon single lumen catheter and 81 (30%) with polyurethane double lumen catheter devices, were analysed. The distribution of demographic, clinical, therapeutic and cathers insertion procedure variables were homogeneous between the two groups of catheters, except for the variables: previous diagnosis of septicemia (p=0,0210) and difficulty on the progression of the catheter during the catheter instalation (p=0,0296). However, the p value for homogeneity test for the odds ratio for the diagnosis of septicemia and the difficulty of catheter progression, no have statistical difference, respectively p=0,955 and p=0,400. The rate of incidence density (ID) for non-elective silicon single lumen catheter removal was 34,8 per 1.000 catheter-days and for the polyurethane double lumen catheter was 32,8 per 1.000 catheter-days. Difference statistically significant, p=0,0005, in the average of length of stay between the two types of catheters was found, the polyurethane double lumen was largest, 14 days, silicone single lumen was 10 days. However, it is not possible to state that the rate of incidence density between the catheters is different when estimated by the Kaplan Meier method survival curve of the catheters with non-elective removal. The survival curves of both catheters overlap in 20th to 25th days, and the logrank value, 0,45, indicates no statistical difference in the non-elective removal catheters incidences between the two types of catheters. Thus, the statistical hypothesis in the length of stay of non-elective removal between both catheters can not be rejected, not confirming the theoretical hypothesis of this study. Conclusion: The results of the study indicate that there is no statistically significant difference in the incidence rates of non-elective removal between the two types of catheters. However, the polyurethane double lumen catheter had higher length of stay mean compared to the silicone single lumen catheter.
23

Análise da relação entre a posição anatômica da ponta do cateter CCIP e o motivo de remoção do dispositivo em uma coorte de neonatos / Analysis of the relation between anatomical location of PICC tip and the reason for the removal of the device in a cohort of neonates

Costa, Priscila 24 November 2011 (has links)
Introdução: O uso do Cateter Central de Inserção Periférica (CCIP) vem sendo cada vez mais frequente em neonatos internados em Unidades de Terapia Intensiva Neonatal (UTIN) em razão da necessidade de um dispositivo de acesso venoso seguro para infusão de drogas irritantes e nutrição parenteral. Detalhes técnicos do CCIP, especialmente a posição anatômica de sua ponta são descritos como fatores de risco para complicações que podem culminar em remoção não eletiva do dispositivo. Objetivo: analisar a relação entre a posição anatômica da ponta do CCIP e o motivo de remoção do dispositivo em uma coorte de neonatos. Método: coorte concorrente, composta por neonatos submetidos à instalação do CCIP, internados em UTIN de um hospital privado da cidade de São Paulo no período de 31 de agosto de 2010 a 01 de julho de 2011. Os neonatos foram incluídos no estudo no momento da instalação do cateter e acompanhados durante a permanência do dispositivo. O projeto de pesquisa foi apreciado e aprovado pelo Comitê de Ética em Pesquisa da instituição, campo do estudo (Processo 238/2010). Resultados: foram analisados dados referentes a 237 CCIPs, dos quais, 207 (86,9%) tiveram posicionamento central da ponta (grupo central) e 30 (12,5%) posição não central da ponta (grupo não central). Nos grupos central e não central, as médias da idade gestacional corrigida, idade pós-natal e peso foram, respectivamente: 34,1 semanas e 33,8 semanas; 9,9 dias e 10,4 dias; 1.936,8 gramas e 1.867 gramas, com homogeneidade entre os grupos, exceto em relação ao diagnóstico de afecção cardíaca, com maior proporção no grupo com cateter não central (p=0,0472). O sitio de inserção, tipo de cateter e terapia intravenosa instituída foram semelhantes entre os grupos. A maioria dos CCIPs (62,3%) foi removida eletivamente. A incidência de remoção não eletiva do CCIP foi maior entre os cateteres não centrais (43,3%), em comparação aos centrais (36,7%) não apresentando diferença estatisticamente significante entre os grupos (p=0,4842). O risco relativo de remoção não eletiva foi 1,18 (IC 95%: 0,76-1,84) vezes maior para os cateteres não centrais. Os principais motivos de remoção não eletiva nos cateteres centrais foram obstrução, ruptura e suspeita de infecção de corrente sanguínea relacionada a cateter, e nos cateteres não centrais foram: tração acidental, suspeita de infecção de corrente sanguínea relacionada a cateter e extravasamento. Houve diferença estatística significante quanto à incidência de extravasamento nos cateteres não centrais em relação aos centrais (p=0,0092). A taxa de incidência (TI) de extravasamento foi 0,8 por 1.000 cateteres-dia em cateteres centrais e 10,2 por 1.000 cateteres-dia nos cateteres não centrais. As médias do tempo de permanência dos cateteres não centrais e centrais foram respectivamente de 9,8 dias e 11,7 dias sem diferença estatisticamente significante (p=0,1627). Conclusão: Os achados sugeriram não haver associação entre o posicionamento não central da ponta do CCIP e a ocorrência de remoção não eletiva do cateter. Entretanto, há necessidade de avaliação permanente do neonato quanto aos sinais de extravasamento / Background: The use of Peripherally Inserted Central Catheters (PICC lines) has become common in neonates admitted to Neonatal Intensive Care Units (NICU), due to the necessity of safe intravenous access for irritant drugs and parenteral nutrition. Some technical details of the PICC, especially the anatomical location of its tip are described as risk factors for complications leading to nonelective removal of this device. Aim: Analyze the relation between anatomical location of the PICC tip and the reason for the removal of the device. Methods: Prospective cohort, composed of neonates who underwent placement of the PICC, admitted to a private NICU in the city of São Paulo, from 31 August 2010 to 1st July 2011. The infants were enrolled after successfully catheter insertion and they were followed up until its removal. The research project was appraised and approved by the Ethics Committee of the institution, (Case 238/2010). Results: Data from 237 PICCs were analyzed, 207 (86.7%) were central in tip location (central group), and 30 (12.5%) were noncentral in tip location (non central group). At central and noncentral groups, the means of corrected gestational age, postnatal age and weight were respectively: 34.1 weeks and 33.8 weeks, 9.9 days and 10.4 days, 1936. 8 grams and 1.867 grams, both groups are homogeneous, except for the diagnosis of heart disease, with the highest proportion in the noncentral group (p=0.0472). The site of insertion, type of catheter and intravenous therapy were similar in both groups. Most of PICCs (62.3%) was removed electively. The incidence of nonelective removal was higher among noncentral catheters (43.3%) compared to central (36.7%) with no statistical significant difference (p = 0.4842). The noncentral group had a 1.18-fold increased risk of nonelective removal compared to central catheters. The main reasons for nonelective removal at the central group were obstruction, rupture and suspicion of catheter-related bloodstream infection, and at the noncentral group were accidental dislodgment, suspicion of catheter-related bloodstream infection and extravasation. There was a statistically significant difference in the incidence of extravasation at the noncentral group compared to central group (p=0.0092). The extravasation rate was 0.8 per 1.000 catheter-days at central group and 10.2 per 1.000 catheter-days at noncentral group. The catheter indwelling time at noncentral and central catheters were respectively 9.8 days and 11.7 days with no statistically significant difference (p=0.1627). Conclusion: The results suggested no association between noncentral tip location of the PICC and the occurrence of nonelective removal of the catheter. However, a continuous assessment of the neonate for the signs of extravasation is needed.
24

Detecção de pneumotórax em tempo real através da tomografia de impedância elétrica / Real-time detection of pneumothorax using electrical impedance tomography

Costa, Eduardo Leite Vieira 18 June 2008 (has links)
Introdução: Pneumotórax é uma complicação comum em pacientes sob ventilação mecânica. Se não reconhecido, tende a aumentar de volume e pode levar ao colapso cardiovascular. Os métodos utilizados para seu diagnóstico caracterizam-se por baixa sensibilidade (radiografia) ou envolvem transporte potencialmente arriscado à tomografia de raios X. A tomografia de impedância elétrica (TIE) é um método não invasivo que permite monitorização da ventilação em tempo real. O método é baseado na construção da imagem de uma seção transversal das condutividades torácicas através de eletrodos dispostos ao redor do tórax. A TIE correlaciona-se muito bem com as alterações regionais do conteúdo de ar dentro do tórax. Por ter baixo custo, não ser invasiva e ter alta sensibilidade às alterações da ventilação e aeração pulmonar, a TIE é um método promissor para a detecção de pneumotóraces em situações de alto risco. Os objetivos deste estudo foram: 1) caracterizar as alterações na TIE relacionadas ao aparecimento de pneumotórax; 2) desenvolver um algoritmo para detecção automática de pneumotóraces e 3) avaliar prospectivamente a sensibilidade e especificidade deste algoritmo. Métodos: Foram realizados experimentos em 39 porcos (peso médio 31,0 Kg ± 3,2 desvios-padrão). Os animais foram sedados e submetidos à ventilação mecânica. Os dados de TIE foram adquiridos através de um tomógrafo de impedância desenvolvido por nosso grupo (Laboratório de Pneumologia Experimental, Escola Politécnica da Universidade de São Paulo e Dixtal Biomédica Ltda., São Paulo, Brasil), capaz de produzir 50 imagens relativas por segundo. Um primeiro grupo de dez animais foi submetido à drenagem torácica com indução progressiva de pneumotórax através do dreno (de 0 a 500 mL). No grupo seguinte, induzimos lesão pulmonar através de lavagem com salina em oito animais e os submetemos a mudanças progressivas de PEEP. Essas duas primeiras etapas foram utilizadas para a construção de um detector automático de pneumotórax baseado na TIE que foi testado prospectivamente em outros 21 animais. Resultados: A TIE apresenta alterações bem definidas relacionadas ao surgimento de pneumotórax, caracterizadas por aumento da impedância média e diminuição da amplitude da impedância concentrados no quadrante de interesse. Por outro lado, os achados na TIE durante mudanças bruscas de PEEP se distribuíram homogeneamente nos quatro quadrantes. A TIE apresentou alterações significativas mesmo com os menores volumes de ar injetados (20 mL), enquanto as demais variáveis monitorizadas foram pouco sensíveis ao surgimento do pneumotórax. A pressão arterial teve uma pequena queda com volumes superiores a 500 mL, e a pressão parcial de oxigênio arterial diminuiu somente com volumes maiores que 100 mL. Na fase prospectiva do protocolo, a TIE mostrou sensibilidade de 100% e especificidade de 95% para a detecção de pneumotóraces. A localização do pneumotórax foi identificada corretamente em todos os casos. Conclusão: A TIE apresenta alterações reprodutíveis relacionadas ao aparecimento de ar no espaço pleural caracterizadas por aumento da impedância média e diminuição da amplitude de impedância. Foi possível criar um algoritmo baseado nessas alterações capaz de detectar precoce e precisamente pneumotóraces em situações de risco. O processo de detecção é automático e em tempo real. / Introduction: Pneumothorax is a frequent complication during mechanical ventilation. Electrical impedance tomography (EIT) is a noninvasive tool that allows real-time imaging of regional ventilation. The purpose of this study was to: 1) identify characteristic changes in the EIT signals associated with pneumothoraces; 2) develop and fine-tune an algorithm for their automatic detection; and 3) prospectively evaluate this algorithm for its sensitivity and specificity in detecting pneumothoraces in real time. Methods: prospective controlled laboratory animal investigation. Setting: Experimental Pulmonology Laboratory of the University of Sao Paulo. Subjects: 39 anesthetized mechanically ventilated supine pigs (31.0 ± 3.2Kg, mean ± standard deviation). Interventions: In a first group of 18 animals monitored by EIT, we either injected progressive amounts of air (from 20 up to 500 mL) through chest tubes, or we applied large PEEP increments to simulate extreme lung overdistension. This first data set was used to calibrate an EIT-based pneumothorax detection algorithm. Subsequently, we evaluated the real-time performance of the detection algorithm in 21 additional animals (with normal or pre-injured lungs), submitted to multiple ventilatory interventions or traumatic punctures of the lung. Results: primary EIT relative images were acquired on-line (50 images/second) and processed according to a few imaging-analysis routines running automatically and in parallel. Pneumothoraces as small as 20mL could be detected with a sensitivity of 100% and specificity 95% and easily distinguished from parenchymal overdistension induced by PEEP or recruiting maneuvers. Their location was correctly identified in all cases, with a total delay of only 3 respiratory cycles. Conclusion: We created an EIT-based algorithm capable of detecting early signs of pneumothoraces in high-risk situations, which also identifies its location. It requires that the pneumothorax occurs or enlarges at least minimally during the monitoring period. Such detection was operator-free and in quasi real-time, opening opportunities for improving patient safety during mechanical ventilation.
25

Parecer técnico-científico: uso do conector sem agulha para sistema fechado de infusões vasculares / Technical-scientific opinion: use of the needleless connector for a closed vascular infusion system

Roque, Simone Cristina da Silva 23 February 2018 (has links)
Submitted by SIMONE CRISTINA DA SILVA SANTOS (simoneenfer2009@gmail.com) on 2019-01-31T10:36:29Z No. of bitstreams: 1 SIMONE CRISTINA DA SILVA ROQUE.pdf: 1347038 bytes, checksum: 9722d99fa9ab996c4b434e523d42e4dd (MD5) / Approved for entry into archive by Luciana Pizzani null (luciana@btu.unesp.br) on 2019-01-31T10:54:03Z (GMT) No. of bitstreams: 1 roque_scs_ms_bot.pdf: 1347038 bytes, checksum: 9722d99fa9ab996c4b434e523d42e4dd (MD5) / Made available in DSpace on 2019-01-31T10:54:03Z (GMT). No. of bitstreams: 1 roque_scs_ms_bot.pdf: 1347038 bytes, checksum: 9722d99fa9ab996c4b434e523d42e4dd (MD5) Previous issue date: 2018-02-23 / Introdução: A terapia intravenosa é um procedimento rotineiro nas instituições de saúde, requerendo, portanto, acessórios que favoreçam a realização da técnica. Dentre eles destacam-se os conectores para acesso ao sistema de infusão, uma inovação tecnológica com potencial influência nos resultados das infecções nosocomiais. Objetivo: Avaliar a evidência científica disponível sobre o uso do conector sem agulha para sistema fechado de infusões vasculares em pacientes hospitalizados em instituições de saúde. Metodologia: Foi realizada uma busca até 01 de agosto de 2017 nas bases de dados The Cochrane Library, EMBASE, PubMed e Literatura Latino-Americana e do Caribe em Ciências da Saúde (LILACS). Foram incluídos estudos de Revisões Sistemáticas (RS) e Ensaios Clínicos Randomizados (ECR). Não houve restrição de idioma e ano de publicação do artigo. Os resultados das bases de dados foram agrupados e eliminados os estudos em duplicatas. Em seguida, aplicados os critérios de elegibilidade para os títulos e resumos, restando 23 estudos para leitura completa. Após leitura dos artigos na íntegra, foram selecionados 3 estudos que comparassem os conectores sem agulha para acesso por sistema fechado e oclusores/conectores convencionais por sistema aberto e os conectores sem agulha para acesso por sistema fechado e oclusores/conectores convencionais por sistema fechado. Resultados: Para os desfechos infecção de corrente sanguínea relacionada ao cateter, colonização da ponta de cateter e colonização/contaminação da entrada de hub, não foram encontradas diferenças significativas entre os grupos. Conclusão: Considerando as evidências científicas, a recomendação da tecnologia avaliada é incerta para redução das infecções hospitalares. / Introduction: Intravenous therapy is a routine procedure in health institutions, requiring, therefore, accessories that favor the performance of the technique. Among them, the connectors for access to the infusion system, a technological innovation with potential influence on the results of nosocomial infections, stand out. Objective: To evaluate the available scientific evidence on the use of the needleless connector for closed system of vascular infusions in patients hospitalized in health institutions. Methodology: A search was performed until August 1, 2017 in the databases The Cochrane Library, EMBASE, PubMed and Latin American and Caribbean Literature in Health Sciences (LILACS). We included studies of Systematic Reviews (RS) and Randomized Clinical Trials (RCTs). There was no language restriction and year of publication of the article. The results of the databases were grouped and the duplicate studies were eliminated. Then, the eligibility criteria for the titles and abstracts were applied, leaving 23 studies for complete reading. After reading the articles in full, 3 studies comparing needleless connectors for closed system access and conventional open system occluders / connectors and needleless connectors for closed system access and conventional closed system occluders / connectors were selected. Results: For catheter-related bloodstream infection, catheter-tip colonization, and colonization / contamination of the hub entrance, no significant differences were found between groups. Conclusion: Considering the scientific evidence, the recommendation of the technology evaluated is uncertain for the reduction of hospital infections.
26

Adesividade e irritação cutânea do filme transparente gel de clorexidina em pacientes submetidos ao transplante de células tronco hematopoiéticas / Adhesiveness and skin rash related to the transparent film dressing with chlorhexidine gel applied to patients submitted to hematopoietic stem cell transplantation

Bruna Nogueira dos Santos 21 September 2015 (has links)
O Transplante de Células-Tronco Hematopoéticas (TCTH) trata-se da substituição das Células-Tronco Hematopoéticas (CTH) doentes de um indivíduo por CTH normais com o objetivo de normalizar a hematopoese do receptor. O cateter venoso central (CVC) tornou-se indispensável para viabilizar tal terapêutica pela segurança na infusão das CTH e dos quimioterápicos. Para o TCTH são utilizados cateteres do tipo Hickman ou duplo lúmen, ambos de longa permanência. O curativo adesivo utilizado no sítio de inserção do cateter é essencial para a fixação do cateter, proteção contra agentes externos e prevenção de infecção. Há forte evidência clínica no uso do filme transparente gel de clorexidina (CHX) como uma alternativa no controle de infecções relacionadas ao cateter. A adesividade deste curativo confere-lhe uma possível permanência de até sete dias aderido à pele, o que evita repetidas aplicações e remoções do curativo, diminui a frequência na manipulação do cateter, a ocorrência de infecção e irritação cutânea local. Observa-se que a adesividade do curativo nem sempre permite a permanência por sete dias, sendo necessárias trocas não planejadas, podendo causar lesões à integridade cutânea. Neste estudo, objetivou-se avaliar a adesividade e a irritação cutânea do filme transparente gel de CHX aplicado no sítio de inserção do CVC por meio de um estudo transversal, prospectivo, realizado em um hospital público de ensino, no período de novembro de 2013 a junho de 2014, com crianças e adultos de ambos os sexos com doenças autoimunes ou onco-hematológicas submetidos ao TCTH. A amostra desta pesquisa foi constituída por 25 pacientes. Onze (44%) apresentaram irritação cutânea caracterizada por perda de pele de extensão <=0,5cm, perda de pele de extensão > 0,5cm, placa eritematosa e vesículas. Destes, seis tiveram necessidade de suspensão do uso do curativo. A pele fragilizada devido ao uso de agentes quimioterápicos pode aderir fortemente ao curativo adesivo, sendo desprendida com o mesmo quando este é removido. A perda da integridade cutânea com remoção da camada protetora da pele facilita a entrada de microrganismos aumentando a susceptibilidade a infecções em pacientes imunossuprimidos. Em 55,6% das avaliações foi observado desprendimento do curativo e a região da fenda foi onde mais ocorreu desprendimento (43,4%). Esta é uma região da margem do curativo, assim denominada por possuir uma abertura no adesivo onde são posicionadas as vias do cateter. Infere-se que devido à mobilidade do paciente e manuseio das vias do cateter, com o passar dos dias, essa região da borda do curativo apresenta maior desprendimento. Em 8,4% das observações havia bolha de ar no gel de clorexidina envolvendo o sítio de inserção do cateter. A bolha de ar no gel de clorexidina significa que este não está em contato com a pele do paciente o que é preocupante quando envolve o sítio de inserção do cateter, pois a CHX não está exercendo sua função antisséptica neste local, onde há possibilidade de migração extra- lúmen de microrganismos à corrente sanguínea / Hematopoietic stem cell transplantation (HSCT) involves the replacement of sick hematopoietic stem cells (HSC) from an individual with normal HSC, with the aim to restore the recipient\'s hematopoiesis. Central venous catheters (CVC) have become indispensable to make this therapy feasible due to the safety of infusion of the HSC and the chemotherapeutic agents. In HSCT, long-term Hickman or long-term double lumen catheters are used. The adhesive dressing used in the site of insertion of the catheter is essential for the catheter fixation, protection against external agents and prevention of infection. There is strong clinical evidence on the use of transparent film dressing with chlorhexidine gel (CHX) as an alternative in the control of catheter-related infections. The adhesiveness of this dressing allows it to be used up to seven days once it adheres to the skin, which avoids repeated dressing applications and removals, and reduces the frequency of catheter handling, the occurrence of infection, and local skin rash. However, as observed, the dressing adhesiveness does not always allow it to be used for seven days, and unplanned replacements may be needed, which can cause lesions to the skin integrity. The objective of this study was to evaluate the adhesiveness and skin rash related to the transparent film dressing with CHX gel applied at the site of insertion of the CVC by means of a cross-sectional, prospective study developed at a public teaching hospital, between November 2013 and June 2014, with children and adults of both genders with autoimmune or onco-hematological diseases who were submitted to HSCT. The sample comprised 25 patients. Eleven (44%) presented skin rash characterized by skin loss to an extension of <=0.5 cm, skin loss to an extension of > 0.5 cm, erythematous plaque and vesicles. Of these, six had to interrupt the use of the dressing. Frail skin due to the use of chemotherapeutic agents can adhere strongly to the adhesive dressing, coming off with the dressing at its removal. The loss of skin integrity with the removal of the skin\'s protective layer facilitates the entrance of microorganisms, increasing susceptibility to infections in immunosuppressed patients. In 55.6% of the evaluations, there was dressing detachment, and it was greater in the opening region (43.4%), which is a region in the dressing border with a break in the adhesive where the catheter is placed. Given the mobility of the patient and the handling of the catheter, over the days, this region of the dressing border presents greater detachment. In 8.4% of the observations there were air bubbles in the chlorhexidine gel involving the site of insertion of the catheter. Air bubbles in the chlorhexidine gel means that it is not in contact with the patient\'s skin, which is a cause of concern when the site of insertion of a catheter is involved, since CHX is not exerting its antiseptic function in this location, which can lead to extra-lumen migration of microorganisms to the bloodstream
27

Detecção de pneumotórax em tempo real através da tomografia de impedância elétrica / Real-time detection of pneumothorax using electrical impedance tomography

Eduardo Leite Vieira Costa 18 June 2008 (has links)
Introdução: Pneumotórax é uma complicação comum em pacientes sob ventilação mecânica. Se não reconhecido, tende a aumentar de volume e pode levar ao colapso cardiovascular. Os métodos utilizados para seu diagnóstico caracterizam-se por baixa sensibilidade (radiografia) ou envolvem transporte potencialmente arriscado à tomografia de raios X. A tomografia de impedância elétrica (TIE) é um método não invasivo que permite monitorização da ventilação em tempo real. O método é baseado na construção da imagem de uma seção transversal das condutividades torácicas através de eletrodos dispostos ao redor do tórax. A TIE correlaciona-se muito bem com as alterações regionais do conteúdo de ar dentro do tórax. Por ter baixo custo, não ser invasiva e ter alta sensibilidade às alterações da ventilação e aeração pulmonar, a TIE é um método promissor para a detecção de pneumotóraces em situações de alto risco. Os objetivos deste estudo foram: 1) caracterizar as alterações na TIE relacionadas ao aparecimento de pneumotórax; 2) desenvolver um algoritmo para detecção automática de pneumotóraces e 3) avaliar prospectivamente a sensibilidade e especificidade deste algoritmo. Métodos: Foram realizados experimentos em 39 porcos (peso médio 31,0 Kg ± 3,2 desvios-padrão). Os animais foram sedados e submetidos à ventilação mecânica. Os dados de TIE foram adquiridos através de um tomógrafo de impedância desenvolvido por nosso grupo (Laboratório de Pneumologia Experimental, Escola Politécnica da Universidade de São Paulo e Dixtal Biomédica Ltda., São Paulo, Brasil), capaz de produzir 50 imagens relativas por segundo. Um primeiro grupo de dez animais foi submetido à drenagem torácica com indução progressiva de pneumotórax através do dreno (de 0 a 500 mL). No grupo seguinte, induzimos lesão pulmonar através de lavagem com salina em oito animais e os submetemos a mudanças progressivas de PEEP. Essas duas primeiras etapas foram utilizadas para a construção de um detector automático de pneumotórax baseado na TIE que foi testado prospectivamente em outros 21 animais. Resultados: A TIE apresenta alterações bem definidas relacionadas ao surgimento de pneumotórax, caracterizadas por aumento da impedância média e diminuição da amplitude da impedância concentrados no quadrante de interesse. Por outro lado, os achados na TIE durante mudanças bruscas de PEEP se distribuíram homogeneamente nos quatro quadrantes. A TIE apresentou alterações significativas mesmo com os menores volumes de ar injetados (20 mL), enquanto as demais variáveis monitorizadas foram pouco sensíveis ao surgimento do pneumotórax. A pressão arterial teve uma pequena queda com volumes superiores a 500 mL, e a pressão parcial de oxigênio arterial diminuiu somente com volumes maiores que 100 mL. Na fase prospectiva do protocolo, a TIE mostrou sensibilidade de 100% e especificidade de 95% para a detecção de pneumotóraces. A localização do pneumotórax foi identificada corretamente em todos os casos. Conclusão: A TIE apresenta alterações reprodutíveis relacionadas ao aparecimento de ar no espaço pleural caracterizadas por aumento da impedância média e diminuição da amplitude de impedância. Foi possível criar um algoritmo baseado nessas alterações capaz de detectar precoce e precisamente pneumotóraces em situações de risco. O processo de detecção é automático e em tempo real. / Introduction: Pneumothorax is a frequent complication during mechanical ventilation. Electrical impedance tomography (EIT) is a noninvasive tool that allows real-time imaging of regional ventilation. The purpose of this study was to: 1) identify characteristic changes in the EIT signals associated with pneumothoraces; 2) develop and fine-tune an algorithm for their automatic detection; and 3) prospectively evaluate this algorithm for its sensitivity and specificity in detecting pneumothoraces in real time. Methods: prospective controlled laboratory animal investigation. Setting: Experimental Pulmonology Laboratory of the University of Sao Paulo. Subjects: 39 anesthetized mechanically ventilated supine pigs (31.0 ± 3.2Kg, mean ± standard deviation). Interventions: In a first group of 18 animals monitored by EIT, we either injected progressive amounts of air (from 20 up to 500 mL) through chest tubes, or we applied large PEEP increments to simulate extreme lung overdistension. This first data set was used to calibrate an EIT-based pneumothorax detection algorithm. Subsequently, we evaluated the real-time performance of the detection algorithm in 21 additional animals (with normal or pre-injured lungs), submitted to multiple ventilatory interventions or traumatic punctures of the lung. Results: primary EIT relative images were acquired on-line (50 images/second) and processed according to a few imaging-analysis routines running automatically and in parallel. Pneumothoraces as small as 20mL could be detected with a sensitivity of 100% and specificity 95% and easily distinguished from parenchymal overdistension induced by PEEP or recruiting maneuvers. Their location was correctly identified in all cases, with a total delay of only 3 respiratory cycles. Conclusion: We created an EIT-based algorithm capable of detecting early signs of pneumothoraces in high-risk situations, which also identifies its location. It requires that the pneumothorax occurs or enlarges at least minimally during the monitoring period. Such detection was operator-free and in quasi real-time, opening opportunities for improving patient safety during mechanical ventilation.
28

Parecer técnico-científico uso do conector sem agulha para sistema fechado de infusões vasculares /

Roque, Simone Cristina da Silva January 2018 (has links)
Orientador: Silvana Andréa Molina Lima / Resumo: Introdução: A terapia intravenosa é um procedimento rotineiro nas instituições de saúde, requerendo, portanto, acessórios que favoreçam a realização da técnica. Dentre eles destacam-se os conectores para acesso ao sistema de infusão, uma inovação tecnológica com potencial influência nos resultados das infecções nosocomiais. Objetivo: Avaliar a evidência científica disponível sobre o uso do conector sem agulha para sistema fechado de infusões vasculares em pacientes hospitalizados em instituições de saúde. Metodologia: Foi realizada uma busca até 01 de agosto de 2017 nas bases de dados The Cochrane Library, EMBASE, PubMed e Literatura Latino-Americana e do Caribe em Ciências da Saúde (LILACS). Foram incluídos estudos de Revisões Sistemáticas (RS) e Ensaios Clínicos Randomizados (ECR). Não houve restrição de idioma e ano de publicação do artigo. Os resultados das bases de dados foram agrupados e eliminados os estudos em duplicatas. Em seguida, aplicados os critérios de elegibilidade para os títulos e resumos, restando 23 estudos para leitura completa. Após leitura dos artigos na íntegra, foram selecionados 3 estudos que comparassem os conectores sem agulha para acesso por sistema fechado e oclusores/conectores convencionais por sistema aberto e os conectores sem agulha para acesso por sistema fechado e oclusores/conectores convencionais por sistema fechado. Resultados: Para os desfechos infecção de corrente sanguínea relacionada ao cateter, colonização da ponta de cateter e col... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Introduction: Intravenous therapy is a routine procedure in health institutions, requiring, therefore, accessories that favor the performance of the technique. Among them, the connectors for access to the infusion system, a technological innovation with potential influence on the results of nosocomial infections, stand out. Objective: To evaluate the available scientific evidence on the use of the needleless connector for closed system of vascular infusions in patients hospitalized in health institutions. Methodology: A search was performed until August 1, 2017 in the databases The Cochrane Library, EMBASE, PubMed and Latin American and Caribbean Literature in Health Sciences (LILACS). We included studies of Systematic Reviews (RS) and Randomized Clinical Trials (RCTs). There was no language restriction and year of publication of the article. The results of the databases were grouped and the duplicate studies were eliminated. Then, the eligibility criteria for the titles and abstracts were applied, leaving 23 studies for complete reading. After reading the articles in full, 3 studies comparing needleless connectors for closed system access and conventional open system occluders / connectors and needleless connectors for closed system access and conventional closed system occluders / connectors were selected. Results: For catheter-related bloodstream infection, catheter-tip colonization, and colonization / contamination of the hub entrance, no significant differences were foun... (Complete abstract click electronic access below) / Mestre
29

O enfermeiro e a utilização do cateter central de inserção periférica em recém-nascidos: contribuições à luz da segurança e bioética / The nurse and the use of peripferally inserted central catheters in newborns: contributions based on safety and bioethics

Hérica Matos De Luca 14 January 2015 (has links)
Esta pesquisa teve como objeto de estudo a segurança do recém-nascido no processo de utilização do Cateter Central de Inserção Periférica (PICC) e, como objetivos: conhecer o significado de segurança para o enfermeiro no processo de utilização do PICC em recém-nascidos; descrever os cuidados prestados pelo enfermeiro no uso do PICC em recém-nascidos e analisar os nexos entre segurança e os princípios bioéticos no uso do PICC em recém-nascidos na prática assistencial dos enfermeiros. Trata-se de um estudo descritivo de abordagem qualitativa. O cenário foi a unidade de terapia intensiva neonatal de um Hospital Universitário localizado no município do Rio de Janeiro e os sujeitos, 11 enfermeiros plantonistas capacitados e que realizam a implantação do PICC em recém-nascidos. Para a coleta de dados realizou-se a entrevista semiestruturada, gravada em fita cassete, entre os meses de março e junho de 2012. Posteriormente estas foram transcritas e analisadas por meio da análise de conteúdo de Bardin, na modalidade temática e interpretada à luz dos princípios bioéticos e da segurança do paciente. Como resultados emergiram 04 categorias: Técnicas e Procedimentos, Cuidados com o recém-nascido, Aspectos relacionados à equipe e Aspectos relacionados à família. Para os enfermeiros, segurança no processo de utilização do PICC no recém-nascido, significa saber indicar o uso deste dispositivo de acordo com as peculiaridades de cada criança. Exercer cuidados antes, durante e após o uso do cateter, valorizar os cuidados técnicos relacionados ao procedimento, possuir conhecimento teórico-prático e ter disponibilidade de recursos materiais e humanos para desenvolver um cuidado seguro. Além de atentar para os registros e protocolos da unidade acerca desta prática assistencial. Para preservar a segurança do neonato, compreendem ser necessária a tomada de decisão em conjunto com o médico acerca do momento ideal para se implantar este dispositivo, bem como a escolha do tipo ideal de sedação para o mesmo, dentre outros aspectos. No processo de utilização do PICC, os enfermeiros entendem a manutenção da temperatura corporal, a realização de medidas de conforto perante a dor, a prevenção de infecções e o posicionamento adequado do recém-nascido durante o procedimento, como atitudes essenciais para a promoção de sua segurança. Buscam, também, esclarecer os pais quanto ao procedimento que será realizado com seu filho. Conclui-se que o enfermeiro, no que diz respeito à prática do PICC, atua de acordo com os princípios bioéticos de beneficência e não-maleficência, já que realiza sua assistência visando o bem-estar do neonato, procurando minimizar os desconfortos associados a esse procedimento. Apesar de esclarecerem os pais quanto ao procedimento que será realizado com seu filho, alguns enfermeiros, não os consultam previamente acerca da autorização para implantação deste dispositivo infringindo, assim, o princípio bioético da autonomia. / This research had as its object of study the safety of the newborn in the process of using the Peripherally Inserted Central Catheter (PICC) and its objectives: know the meaning of safety for nurses in the process of PICC use in newborns; describe the care provided by nurses using PICC in newborns and analyze the nexus between security and bioethical principles in the use of PICC in newborns in care practice of the nurses. This is a descriptive qualitative approach, characterized as an exploratory cross-sectional survey, depending on the object of study selected. The scenario chosen was the Neonatal Intensive Care Unit of a University Hospital located in the municipality of Rio de Janeiro and the subjects were eleven nurses on duty trained to use the PICC in newborns. To collect data, semi-structured interview was conducted between the months of march and june 2012, and the responses were recorded on cassette tapes. Thereafter began the content analysis proposed by Bardin and interpretation of results was made according to the concepts of patient safety and bioethics. As results emerged four categories: Techniques and Procedures, Care of the newborn, Aspects related to the team and Aspects related to the family. For nurses, provide security means knowing indicating the PICC according to the peculiarities of each newborn, exercising care before, during and after the use of this catheter, including technical precautions related to the procedure, in addition to having theoretical and practical knowledge and have availability of material and human resources to develop a care insurance. Besides attending to the records and protocols of the healthcare practice about this unit. To preserve the safety of the neonate, be necessary to understand the decision making together with the doctor about the ideal time to deploy this device as well as the choice of the ideal type of sedation for it, among other aspects. In the process of using the PICC nurses understand the maintenance of body temperature, performing comfort measures before pain, infection prevention and appropriate positioning of the baby during the procedure, and attitudes essential for the promotion of their safety. Seek also enlighten parents about the procedure that will be performed with your child. We conclude that the nurse, with regard to the practice of PICC, acts according to bioethical principles of beneficence and non-maleficence as it carries out its assistance for the well-being of the newborn, seeking to minimize the discomfort associated with this procedure. Although enlighten parents about the procedure that will be performed with your child, some nurses, not first consult about the authorization for deployment of this device breaking thus the bioethical principle of autonomy.
30

Custo-efetividade das coberturas para cateter venoso central de curta permanência

Pedrolo, Edivane January 2017 (has links)
Orientadora: Drª Mitzy Tannia Reichembach Danski / Coorientadora: Drª Astrid Wiens Souza / Tese (doutorado) - Universidade Federal do Paraná, Setor de Ciências da Saúde, Programa de Pós-Graduação em Enfermagem. Defesa: Curitiba, 09/08/2017 / Inclui referências : f. 99-117 / Resumo: A infecção primária de corrente sanguínea relacionada ao cateter venoso central de curta permanência (IPCS-CVC) tem elevada incidência nas instituições hospitalares brasileiras e seu tratamento representa elevado custo para os sistemas de saúde. Prevenir esta complicação é a melhor estratégia. Diversas tecnologias estão disponíveis no mercado com esta finalidade, dentre elas as coberturas para cateter venoso central. A presente pesquisa teve como objetivo geral avaliar o custo-efetividade da gaze e fita adesiva, filme semipermeável transparente e cobertura impregnada com clorexidina para cateter venoso central de curta permanência. Como objetivos específicos: elencar evidências científicas relativas aos custos decorrentes da IPCS-CVC; estimar os custos da IPCS-CVC no âmbito do sistema público de saúde; construir a árvore de decisão para as tecnologias estudadas e analisar a relação custo-efetividade de cada alternativa para cobertura do cateter venoso central de curta permanência. A pesquisa foi realizada em três etapas. A primeira consistiu em uma revisão integrativa desenvolvida nas bases de dados LILACS e EMBASE com MEDLINE, publicadas entre jun/2005 e jun/2015 com os descritores: cateteres venosos centrais, infecções relacionadas a cateter e custos e análises de custos. Foram elencadas 13 publicações e houve predomínio de estudos de coorte retrospectiva, desenvolvidos na Europa ou Estados Unidos com pacientes críticos. O custo para um episódio de infecção variou de $24.090 até $34.544. Estudos europeus encontraram valores entre €16.814 e €29.909. A infecção aumentou os dias de internação entre 1,5 e 26 dias, e a mortalidade entre 1,8% e 34%. Na segunda etapa foi desenvolvido um estudo de custo da doença mediante uma pesquisa observacional retrospectiva, realizada em um hospital de ensino da região Sul do Brasil, referente aos pacientes com IPCS-CVC diagnosticados nos anos de 2014 e 2015. Foram incluídos 44 pacientes, os quais representaram um custo total de R$ 417.609,32 para o hospital, com média de R$ 9.711,84 ± R$ 7.008,94 por episódio. Do custo total, a maior parte refere-se aos gastos com internamento (60,98%), seguido do tratamento (37,72%). Custos com a substituição do cateter (0,78%) e com a realização de culturas (0,52%) tiveram pouca representatividade. As infecções causadas por fungos, por microrganismos resistentes e por bactérias gram positivas foram significativamente mais dispendiosas para o hospital. A terceira etapa consistiu em uma análise de custo-efetividade, realizada mediante a construção de uma árvore de decisão na perspectiva do sistema único de saúde brasileiro. Neste cenário a estratégia mais custo-efetiva é a cobertura impregnada com clorexidina, com custo de R$ 2.165,54 por caso evitado e efetividade de 99%. As variáveis custo mínimo, tempo de permanência da cobertura, índice de infecção e de óbito interferiram na relação custo-efetividade. Conhecer o real impacto econômico da IPCS-CVC é importante para que sejam estabelecidos programas e políticas que visem à redução deste agravo. Da mesma forma, estudos de custo-efetividade permitem melhor gestão dos escassos recursos da área da saúde e podem contribuir para que mais indivíduos sejam beneficiados com o uso de tecnologias que, além de efetivas, representam economia para o hospital. PALAVRAS-CHAVE: Enfermagem Baseada em Evidências; Infecções Relacionadas a Cateter; Cateterismo Venoso Central; Custos e Análise de custos; Curativos oclusivos; Tecnologia biomédica. / Abstract: Central-venous-catheter-related bloodstream primary infections (CRBSIs) has a high incidence in Brazilian hospital institutions and its treatment represents a high cost for health systems. Preventing this complication is the best strategy. Many technologies are available in the market for this purpose, among them the central venous catheter coverage. The objective of the present study was to evaluate the cost-effectiveness of gauze and micropore tape, transparent semipermeable film, and chlorhexidine-impregnated coating for short-term central venous catheter. This study has as specific objectives: (1) to list scientific evidence regarding the costs resulting from a CRBSIs; (2) to estimate the costs of a CRBSIs for the public health system; (3) to construct the decision tree for the studied technologies; and (4) to analyze the cost-effectiveness of each alternative for the short-term central venous catheter coverage. The research was carried out in three stages: (1) the first one consisted of an integrative review carried out in the LILACS and EMBASE databases with MEDLINE, published between June 2005 and June 2015 with the descriptors: central venous catheters, catheter-related infections and costs and cost analyses. Results: thirteen publications were included, and there was predominance of retrospective cohort studies conducted in Europe and the United States with critical patients. The cost for an episode of infection ranged from $ 24,090 to $ 34,544. European studies found values between € 16,814 and € 29,909. The infection increased the length of hospitalization between 1.5 and 26 days, and the mortality between 1.8% and 34%; (2) in the second stage, a cost-of-disease study was developed through a retrospective observational research, referring to the patients with CRBSIs diagnosed in 2014 and 2015, and it was carried out in a teaching hospital in the southern region of Brazil. Forty-four patients were included, representing a total cost of R$ 417,609.32 for the hospital, average cost of R$ 9,711.84 ± R$ 7,008.94 per infection episode. Most of the total cost refers to hospitalization expenses (60.98%) followed by treatment (37.72%). Cost with catheter replacement (0.78%) and cultures (0.52%) had little representativeness. Infections caused by fungi, resistant microorganisms, and gram-positive bacteria were significantly more expensive for the hospital; (3) the third stage consisted of a cost-effectiveness analysis, performed through the construction of a decision tree from the perspective of the Brazilian Unified Health System. In this scenario, the most cost-effective strategy is the chlorhexidine-impregnated coating, with a cost of R$ 2,165.54 per avoided case and 99% effectiveness. Knowing the real economic impact of CRBSIs is important to establish programs and policies aiming to reduce this aggravation. Likewise, cost-effectiveness studies allow better management of the scarce health resources and also can contribute to benefit a greater number of individuals, by using technologies that, in addition to being effective, represent expenses saving for the hospital. KEYWORDS: Evidence-Based Nursing; Catheter-Related Infections; Catheterization, Central Venous; Costs and Cost Analysis; Occlusive Dressings; Biomedical Technology.

Page generated in 0.5068 seconds