• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 7
  • 6
  • Tagged with
  • 13
  • 13
  • 7
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Avaliação morfométrica e estereométrica dos tecidos periodontais de ratos imunossuprimidos por Tracolimus (FK506)

Nassar, Carlos Augusto [UNESP] 15 February 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:29Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-02-15Bitstream added on 2014-06-13T20:05:27Z : No. of bitstreams: 1 nassar_ca_dr_arafo.pdf: 644620 bytes, checksum: c8f926b8b07b13ddf9cd03079f1d6f41 (MD5) / Tacrolimus (FK506) é uma droga imunossupressora usada em transplantes de órgãos e também como terapia alternativa em pacientes com rejeição refratária de enxertos ou intolerância à ciclosporina A (CsA), sem os efeitos adversos atribuídos freqüentemente à CsA. Atualmente não há estudos que explorem os efeitos da administração de FK506 por longos períodos sobre o periodonto. Ë sugerido também que terapias imunossupressivas, principalmente com FK506, possam ser um importante fator no desenvolvimento de Diabetes mellitus pós-transplantes (PTDM). Existem alguns estudos explorando os efeitos do FK506 por longos períodos no desenvolvimento da PTDM em protocolos animais. Assim os objetivos do estudo foram avaliar os efeitos da terapia com FK506 por longos períodos sobre os tecidos gengivais, metabolismo do osso alveolar e do cemento de ratos, bem como os efeitos sobre os níveis glicêmicos. Com relação ao metabolismo ósseo, houve uma tendência de diminuição, estatisticamente significante, dos níveis de ALP em todos os períodos tratados com FK506, sendo que com os níveis de cálcio apenas um aumento em 240 dias de tratamento, quando comparados com os grupos controles. Assim, nós podemos concluir que o FK506 em longos períodos pode levar os efeitos deletérios sobre os tecidos gengivais e pode ser dependente da idade, mas não causaria efeitos negativos sobre o osso alveolar e nem ao cemento. E ainda em relação aos níveis séricos de glicemia, os efeitos negativos da terapia com FK506 também são dependentes do tempo. / Tacrolimus (FK506) is an immunosuppressive drug in organ transplantation and it is also an alternative therapy used for transplant patients with either refractory graft rejection or intolerant to cyclosporine A (CsA), without the adverse effects frequently attributed to CsA therapy. Nevertheless there are not studies exploring the effects of long-term FK506 therapy on periodontium. It has been suggested that immunosuppressive therapy, mainly FK506, may be an important factor in the development of post-transplantation diabetes mellitus (PTDM). There is a lack of studies exploring the effects of a long-term FK506 on PTDM in animal's protocols. The objectives of the present study were to evaluate the effects of long-term therapy with FK506 on the gingival tissue, alveolar bone metabolism and cementum in rats and the deleterious glycemic effects of long-term therapy with FK506. There was a tendency of increase of serum glycemia level in the initial periods (60 and 120 days). Within the limits of this experimental study, it can be concluded that the deleterious gingival effects of FK506 administration may be time and age related side effects and that have not the negative effects of FK506 administration long-term on the alveolar bone and cementum. It can be concluded that the deleterious glycemia effects of FK506 therapy may be time related side effects.
12

Influência do plasma rico em plaquetas derivado do aspirado de medula óssea na cicatrização de defeitos periodontais: estudo histológico, histométrico e imunoistoquímico em ratos

Campos, Natália de [UNESP] 21 February 2014 (has links) (PDF)
Made available in DSpace on 2015-05-14T16:53:33Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-02-21Bitstream added on 2015-05-14T16:58:40Z : No. of bitstreams: 1 000822226_20200221.pdf: 179138 bytes, checksum: 4effc9b2a526cfdef9ed06bf7db7b261 (MD5) / Este estudo avaliou a influência do plasma rico em plaquetas derivado do aspirado de medula óssea (PRP-bma) na cicatrização de defeitos de fenestração periodontal (PFD) em ratos. PFD foram criados cirurgicamente na mandíbula de 40 ratos. Os animais foram divididos randomicamente em 2 grupos: C e PRP-bma - os defeitos foram preenchidos com coágulo sanguíneo ou PRP-bma, respectivamente. Os animais foram submetidos à eutanásia aos 10 ou 30 dias pós-operatórios. Foram realizadas análises histológica, histométrica e imunoistoquímica. A porcentagem de novo osso (NB), densidade do novo osso formado (DNB), novo cemento (NC) e extensão do defeito remanescente (ERD) foram avaliados histometricamente. Foram realizadas reações imunoistoquímicas para detecção de antígeno nuclear de proliferação celular (PCNA), sialoproteína óssea (BSP), osteocalcina (OCN) e fosfatase ácida resistente ao tartarato (TRAP). Células imunomarcadas foram quantificadas. Os dados foram analisados estatisticamente (ANOVA; Tukey, P < 0,05). Aos 10 dias, os grupos C e PRP-bma apresentaram quantidades similares de NB e DNB, e não foi observada formação de NC. Aos 30 dias, os grupos C e PRP-bma apresentaram quantidades similares de NB e DNB; o Grupo PRP-bma mostrou significativa formação de NC, com fibras colágenas inseridas obliquamente ou perpendicularmente à superfície radicular, sendo que nenhum espécime do Grupo C apresentou formação de NC. O Grupo PRP-bma apresentou um número significativamente maior de células PCNA-postivas (aos 10 dias) e BSP-positivas (aos 10 e 30 dias) que o Grupo C. Não foram observadas diferenças significativas no número de células OCN-positivas ou TRAP-positivas entre os grupos aos 10 ou 30 dias. Pode-se concluir que o PRP-bma promoveu formação de NC com ligamento periodontal funcional / This study evaluated the influence of platelet-rich plasma derived from bone marrow aspirate (PRP-bma) on the healing of periodontal fenestration defects (PFD) in rats. PFD were surgically created in the mandible of 40 rats. The animals were randomly divided into 2 groups: C and PRP-bma - defects were filled with blood clot or PRP-bma, respectively. Animals were euthanized at either 10 or 30 days post-operative. Histologic, histometric and immunohistochemical analyses were performed. Percentage of new bone (NB), density of newly formed bone (DNB), new cementum (NC) and extension of remaining defect (ERD) were histometrically evaluated. Proliferating cell nuclear antigen (PCNA), bone sialoprotein (BSP), osteocalcin (OCN), and tartrate-resistant acid phosphatase (TRAP) immunohistochemical staining were performed. Immunolabeled cells were quantified. Data were statistically analyzed (ANOVA; Tukey, P < 0.05). At 10 days, groups C and PRP-bma presented similar amounts of NB and DNB, NC formation was not observed. At 30 days, groups C and PRP-bma presented similar amounts of NB and DNB; Group PRP-bma showed significant NC formation, with collagen fibers inserted obliquely or perpendicularly to the root surface, while NC formation was not observed in any Group C specimen. Group PRP-bma presented a significantly higher number of PCNA-positive (at 10 days) and BSP-positive cells (at 10 and 30 days) than Group C. No significant differences in the number of either OCN-positive or TRAP-positive cells were observed between groups at 10 or 30 days. It can be concluded that PRP-bma promoted NC formation with a functional periodontal ligament
13

Comparación in vitro de la precisión dimensional de dos técnicas de impresión

Céspedes Brea, Bárbara Alisson 26 June 2017 (has links)
Objetivo: Comparar in vitro la precisión dimensional de la silicona por condensación mediante la técnica de impresión de doble mezcla; de doble impresión con alivio del margen y doble impresión con alivio total. Materiales y métodos: Las muestras estuvieron conformadas por 42 impresiones utilizando silicona por condensación Putty- Spedeex de un modelo maestro de acero inoxidable, el cual presentó dos pilares homogéneos que simularon la preparación para una corona. Estas muestras se dividieron en 3 grupos según la técnica de impresión (doble mezcla, doble impresión con alivio del margen y doble impresión con alivio total). Para determinar la precisión dimensional de los modelos definitivos en comparación al modelo maestro, se realizaron 7 mediciones (MD1, MD2, VL1, VL2, AL1, AL2, DI) con una máquina especializada en coordenadas, modelo Contura G2 con tecnología de Scanning por contacto ZEISS. Se realizaron las pruebas estadísticas Kruskal-Wallis y U de Mann-Whitney. Resultados: Se encontraron diferencias estadísticamente significativas (p˂0.001) en las medidas MD1, MD2, AL2 al comparar las 3 técnicas de impresión con el modelo maestro. La técnica de doble impresión con alivio total presentó una mayor cantidad de medidas (MD1, MD2, VL1, AL1, DI) que no mostraron diferencias estadísticamente significativas (p<0.005) en comparación al modelo maestro. Conclusiones: La técnica de doble impresión con alivio total presentó mayor precisión dimensional que las técnicas de doble mezcla y la técnica de doble impresión con alivio del margen utilizando silicona de condensación. / Objective: Compare in vitro the dimensional precision of the polivinil siloxano using the technique of impression of double mixture; double impression with margin relief and double impression with total relief. Materials and methods: The samples were composed of 42 impressions using Putty-Spedeex polivinil siloxano from a master stainless steel model, which presented two homogeneous pillars that simulated the preparation for a crown. These samples were divided into 3 groups according to the printing technique (double mix, double impression with margin relief and double impression with total relief). In order to determine the dimensional accuracy of the final models in comparison to the master model, 7 measurements (MD1, MD2, VL1, VL2, AL1, AL2, DI) were performed with a coordinated machine, Contura G2 model with contact scanning technology ZEISS. Statistical tests were performed Kruskal-Wallis and U of Mann-Whitney. Results: Statistically significant differences (p˂0.001) were found in measures MD1, MD2, AL2 when comparing the three printing techniques with the master model. The double impression technique with total relief presented a greater number of measures (MD1, MD2, VL1, AL1, DI) than did not show statistically significant differences (p <0.005) in comparison to the master model. Conclusions: The technique of double impression with total relief presented greater dimensional accuracy than the techniques of double mixing and the technique of double impression with relief of the margin using silicone of condensation.

Page generated in 0.1109 seconds