• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 449
  • 18
  • 18
  • 18
  • 18
  • 14
  • 14
  • 14
  • 14
  • 11
  • 6
  • 4
  • 3
  • 2
  • Tagged with
  • 472
  • 249
  • 127
  • 116
  • 54
  • 54
  • 53
  • 51
  • 51
  • 45
  • 44
  • 40
  • 33
  • 29
  • 27
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

Contribuição ao estudo das alterações da medula espinhal em modelo experimental de lesão traumatica na fase aguda

Leal Filho, Manoel Baldoino 10 August 2004 (has links)
Orientadores: Antonio Guilherme Borges Neto, Konradin Metze / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-04T01:18:13Z (GMT). No. of bitstreams: 1 LealFilho_ManoelBaldoino_D.pdf: 8399962 bytes, checksum: 28257f9a450586d75448f83538f8d1f3 (MD5) Previous issue date: 2004 / Resumo: O autor apresenta uma experiência com 58 ratos Wistar adultos, que foram submetidos a trauma raquimedular torácico com o cateter balão de Fogarty (12-062-2F). Este experimento foi aprovado pela Comissão de Ética em Experimentação Animal (CEEA-IB-Unicamp). Na primeira fase todos os animais, controles e experimentais, foram anestesiados com pentobarbital, 60 mg!Kg. O cateter foi introduzido no espaço epidural, através de uma pequena abertura no ligamentum flavum, até o nível torácico médio e inflado com 20 microlitros de salina apenas nos grupos experimentais. Este estudo objetivou investigar a relação entre a lesão na medula e a compressão medular espinhal durante 5, 15, 30 ou 60 segundos. O exame neurológico quantitativo foi realizado com 4, 24 e 48 horas da compressão, para caracterizar a graduação da lesão nos diferentes grupos. O pior desempenho ocorreu com a compressão de 60 segundos independentemente do tempo do exame. Alguns animais morreram subitamente com edema pulmonar e um segundo estudo foi feito para elucidar este fato. O propósito desta segunda etapa foi mostrar um modelo experimental de edema agudo de pulmão neurogênico usando o cateter balão de Fogarty@ com 20 microlitros de salina durante 60 segundos de compressão (n = 17). Para se verificar a influência do agente anestésico foram utilizados dois tipos diferentes de anestésicos para se avaliar a influência da droga no edema pulmonar e foram formados 3 grupos: controle (1), compressão / pentobarbital, 60 mg/Kg (2) e compressão / xilasina, 10 mgIKg / ketamina, 75 mg lKg (3). Os resultados indicaram que houve diferença entre os grupos. No grupo do pentobarbital a pressão sistólica dobrou em relação ao basal, durante a compressão, no entanto este efeito foi menos pronunciado no grupo xilasina/ketamina. O índice pulmonar (100 x peso pulmonar / peso corporal) foi 0,395%0,018 no controle (1), aumentou para 0,499%0,060 no grupo (3), e foi máximo no grupo 2 (0,639%0,14; p=O,0018). O exame histológico da medula espinhal mostrou lesões no parênquima e hemorragia aguda. Comparando-se o índice pulmonar com o índice morfométrico por microscopia em parafina observou-se que o edema intra-alveolar relevante ocorreu somente para valores de índice pulmonar acima de 0,55. Na microscopia com maenificação de 6300 e 4000 foram evidenciadas alterações no endotélio capilar e no revestimento alveolar. O presente experimento sugere que o edema pulmonar induzido pela compressão espinhal é de natureza neurogênica, que o anestésico teve influência na gênesis do edema e que este é um método de produção de edema pulmonar neurogênico / Abstract: The author report an experience with 58 Wistar adult rats who sustained acute midthoracic spine cord injury due to Fogarty's balloon-compression technique. This experience was approved by the institutional animal care and use committee (CEEA-ffi-Unicamp). In the first step all the animaIs, sham and experimentals, were anesthetized with intraperitoneal pentobarbital 60 mg/Kg. The catheter was inserted into dorsal epidural space through a small hole made in the ligamentum flavum, advanced cranially to midthoracic spinallevel, and inflated with 20 microlitres of saline only in the experimental group. The present study was performed to investigate the relationship between the spine cord injury and the time of compression (5, 15, 30 or 60 seconds). Quantitative neurological outcome was presented with 4, 24 and 48 hours ttom the compression to characterize the graduation of injury in different groups. The poor outcome occured with 60 seconds compression independentely of the time of neurological examination. Some animaIs died suddenly with pulmonary edema and a second step investigation was done to elucidate it. The aim of this second study was to show a model of neurogenic pulmonary edema due to thoracic spine injury using a Fogarty's balloon containing 20 microlitres of saline during 60 seconds of compression (n = 17). There were used two different groups of anesthesics to compare the influence of the drugs on the pulmonary edema and three groups were constituted: sham (1), compression / pentobarbital, 60 mgI.Kg(2) and compression / xylasin, 10 mg/K.g / ketamin, 75 mg/Kg (3). The resuhs indicated that there were differences between the groups. In rats with pentobarbital anesthesia systolic blood pressure doubled the baseline value during compression, whereas this effect was less pronounced in the xylasine/ketamine group. The pulmonary index (100 x wet lung weight / bodyweight) was 0,395:1:0,018in sham (1), rose to 0,499:1:0,060in (3), and was maximum under group 2 (0,639:1:0,14;p=O,0018). Histologic examination of the spinal cord showed parenchymal ruptures and acute hemorrhage. Comparlson of the pulmonary index with morphometric evaluation of edema fluid-filled alveoli by light microscopy in paraffin sections, showed that relevant intra-alveolar edema occured only for index values above 0,55. On electron microscopy, endothelial alterations, and signs of damage of the alveolar lining cells were found. The present study showed that the anesthesic drug pentobarbital was very important for the formation of the lung edema. The present experience suggests that the pulmonary edema induced by spinal compression is of neurogenic nature, that the anesthesic drug used had an important participation in the genesis of edema and that it is a good method to produce neurogenic pulmonmy edema / Doutorado / Neurologia / Doutor em Ciências Médicas
112

Estudo da classificação morfopatologica proposta por Landim para a estenose lombar

Pasqualini, Wagner, 1960- 03 August 2018 (has links)
Orientador: Elcio Landim / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-03T15:28:41Z (GMT). No. of bitstreams: 1 Pasqualini_Wagner_M.pdf: 1266655 bytes, checksum: d3e6214480e3e94d6ca5bbbd7373eea5 (MD5) Previous issue date: 2001 / Resumo: A síndrome da estenose do canal lombar é uma das causas mais freqüente de lombalgia e lombociatalgia, e sua incidência aumentou nas últimas décadas devido à longevidade cada vez maior da população. Foram estudados 55 exames de imagem (tomografia axial computadorizada e ressonância nuclear magnética) e, utilizando a classificação morfopatológica proposta por Landim (1999), observou-se a freqüência de cada tipo da classificação, nas diversas patologias que causam a estenose. Os resultados encontrados coincidem com a literatura existente sobre o tema, sendo a causa degenerativa para a estenose do espaço intervertebral a mais freqüente. Trata-se de uma classificação simples e útil na indicação da via de acesso cirúrgica, associada ou não à artrodese, quando o tratamento cirúrgico estiver indicado / Abstract: The syndrome of the lumbar canal stenosis is one of the most frequent causes of back pain and radicular pain, having increased its occurrences um the past decades due to the also increased longevity of the population. A total of 55 image exams (computerized axial tomography and M.R.I.) have been studied, using Landim morphopathological classification, and the frequency of each kind of classification in the various pathologies has been observed. The results of the study coincide with the availabre literature, showing the degenerative cause as the most frequent one in the lumbar canal stenosis. We consider LANDIM classification simple and very useful as an index for surgical treatment / Mestrado / Cirurgia / Mestre em Cirurgia
113

Extração e caracterização de pectinas por método químico, inflavermelho e HPLC - ELSD

BARBOZA, Marianne de Lima 31 January 2011 (has links)
Made available in DSpace on 2014-06-12T23:02:17Z (GMT). No. of bitstreams: 2 arquivo6684_1.pdf: 1538621 bytes, checksum: 545418e9d1f127b096d57f1272c9058c (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2011 / Este trabalho consiste numa abordagem metodológica de caracterização visando a viabilização de fontes naturais de pectina. Utilizou-se o mesocarpo da melancia (e demais frutos tropicais) como fonte de pectinas para demonstrar a caracterização estrutural por distintos métodos analíticos, considerando desde a etapa de extração até a caracterização estrutural. Foi avaliado o potencial do ácido cítrico e do HCl, em diferentes forças, em temperaturas distintas sobre o rendimento de extração (%) e o grau de metoxilação GM (%). Verificou-se também a influência da cadeia carbônica do álcool durante a precipitação de pectinas isoladas. Os métodos de caracterização estrutural de pectinas (padrões e extraídas de diversas frutas) foram o titulométrico, infravermelho e HPLC acoplado a detecção pelo espalhamento de luz (ELSD). A determinação do GM por infravermelho (IV) foi obtida a partir dos valores de absorbância das bandas 1750 cm-1 e 1650 cm-1. Para determinação por HPLC foram avaliadas as fases estacionárias (ODS-2 e Hiplex) e fases móveis diferenciadas para otimizar a separação e detecção. As melhores condições foram ajustadas ao uso da fase estacionária Hiplex em fase móvel H2SO4 50 mM. As condições de desesterificação dos padrões comerciais de pectinas foram ajustadas variando a força do NaOH, de 0,1 a 3,6 M e tempo de reação (5 min 360 min), exploradas em ensaios multifatoriais. Obteve-se maior rendimento de extração de pectinas (3,38%) e maior GM (76,21%) utilizando o acido cítrico, enquanto que o HCl produziu efeito desmetoxilante. A fase móvel H2SO4 50mM associada a coluna Hiplex fast acid mostraram-se eficazes na separação e detecção do metanol e ácido acético da pectina por HPLC-ELSD. A otimização do procedimento de desesterificação foi ajustada pela variável força molar minimizando a desmetoxilação entre 1,5-2.0 M (p≤0,02) requerendo em tempo de reação de 5-60 min. As condições ideais para tratar padrões comerciais quando asseguradas estatisticamente procedeu-se a curva extraída (N=7) para estudos de regressão e assim repassada para quantificação dos parâmetros estruturais em amostras de pectinas de frutas. As avaliações foram procedidas pelo método de padronização interna e externa que exibiram R2 superior a 0,92. Enquanto para as amostras de pectinas de frutas tropicais o R2 em torno de 0,75, independente do sistema de quantificação
114

"Validação de testes de flexibilidade da coluna lombar" / VALIDATION OF LUMBAR SPINE FLEXIBILITY TESTS

Abdallah Achour Júnior 22 March 2006 (has links)
Esta pesquisa teve como principal objetivo, validar o teste de flexibilidade da coluna lombar (Testprop), utilizando-se da radiografia como teste critério e o teste flexibilidade da coluna lombar de ADRICHEM e KORST (1973) para o sexo feminino e masculino. Participaram 19 mulheres (média de idade= 23,2 anos e desvio padrão= 1,3) e 18 homens (média de idade= 22,3 anos e desvio padrão= 1,4), universitários, saudáveis e ativos do Curso de Educação Física e Ciências do Esporte da Universidade Estadual de Londrina - PR. Inicialmente, verificou-se a fidedignidade e objetividade dos testes de flexibilidade da coluna lombar (Testprop e Testeips). O coeficiente de correlação intraclasse mostrou que o teste de flexibilidade Testprop apresenta fidedignidade elevada para o sexo feminino (R= 0,86) e elevada para o sexo masculino (R=0,85), e demonstrou haver objetividade moderada (R= 0,73) para o sexo feminino e elevada (R= 0,96) para o sexo masculino. Quanto ao teste de flexibilidade Testeips, a fidedignidade foi elevada (R= 0,85) e (R= 0,86) para o sexo feminino e masculino, respectivamente. A objetividade do teste de flexibilidade Testeips foi moderada (R= 0,62) para o sexo feminino e elevada para o sexo masculino (R= 0,91). Em relação à validade, o coeficiente de correlação de Pearson mostrou correlação baixa para o teste de flexibilidade Testprop (r= 0,11) para o sexo feminino e correlação moderada (r= 0,52) para o sexo masculino. No que diz respeito ao teste de flexibilidade Testeips, o coeficiente de correlação de Pearson foi baixo para o sexo feminino (r= 0,24) e moderado para o sexo masculino (r= 0,50). Concluiu-se que os testes de flexibilidade da coluna lombar Testprop e Testeips foram fidedignos e objetivos, mas não foram considerados válidos. / The main goal was to validate the flexibility test for the lumbar spine (Testprop), using x-ray as a criteria and the flexibility test of the lumbar spine designed by ADRICHEM and KORST (1973) for females and males, 19 women participated (mean age= 23,2 years old; standard deviation= 1,3 year old) and 18 men (mean= 22,3 year old and standard deviation = 1,4) healthy and active students from the Physical Education and Sport Science Course at the Universidade Estadual de Londrina-PR. Initially, it was verified reliability and objectivity (Testprop and Testeips) the lumbar spine flexibility. The intraclass correlation coefficient showed that the reliability of test of flexibility Testprop was high for woman (R= 0.86) and high for men (R= 0.85), there was a moderate objectivity (R= 0.73) for women and high (R= 0.96) for men. Concerning the flexibility test Testeips, the reliability was high (R= 0.85) and (R= 0.86) for woman and men, respectively. The objectivity for the flexibility test Testeips was moderate (R= 0.62) for women and high for men (R= 0.91). Concerning the validity, Pearson correlation coeficient demonstrated a low correlation for the flexibility test Testprop (r= 0.11) for women and moderate for men (r= 0.52). About the flexibility test, Testeips, Pearson correlation coefficient was low for woman (r= 0.24) and moderate for men (r= 0.50). It was concluded that the flexibility tests of the lumbar spine Testprop and Testeips were reliable and objective, but they were not considered valid.
115

Avaliação do efeito do uso de sequências sensíveis a líquido na classificação das alterações do tipo Modic na coluna lombar / Evaluation of the effect of the use of fluid sensitive sequences on the classification of Modic type endplate changes in the lumbar spine

Nascimento, Eduardo Deroide do 23 May 2019 (has links)
As alterações de sinal no osso subcondral dos corpos vertebrais foram descritas primeiramente por Modic, correlacionando o espectro das alterações da medula óssea no corpo vertebral relacionadas a discopatias degenerativas. O Modic tipo I representa a alteração de sinal do tipo edema, já o Modic II representa a alteração de sinal com padrão de lipossubstituição e o Modic III representa alteração de sinal relacionada a esclerose óssea. O objetivo primário deste estudo foi avaliar se há alteração na detecção dos padrões da classificação Modic na coluna lombar comparando a técnica Dixon com o protocolo tradicional. Como objetivo secundário avaliamos a correlação intra-observador e interobservador. O estudo foi realizado de forma retrospectiva com a inclusão de pacientes cujas ressonâncias magnéticas (RM) foram realizadas na Central de Diagnóstico Ribeirão Preto (CEDIRP). Dois médicos radiologistas de forma independente classificaram as alterações do tipo Modic permitindo uma avaliação interobservador e um dos radiologistas realizou uma segunda análise dos exames possibilitando uma avaliação intra-observador. Os resultados evidenciaram que a técnica Dixon apresentou superioridade na detecção do Modic I em todas as análises e também apresentou médias mais altas da espessura das alterações no osso subcondral. Houve correlações intra-observador moderadas e substanciais no protocolo tradicional e substanciais a altas com a técnica Dixon. A correlação interobservador demonstrou uma correlação moderada na avaliação deste tipo de alteração nos platôs superior e inferior de L3 e correlação inversa e não significativa para a o platô superior de L5 utilizando o protocolo tradicional. Já a correlação interobservador com a técnica Dixon evidenciou concordância perfeita entre os observadores na avaliação de tipo de alteração de sinal no osso subcondral do platô inferior de L1, correlação inversa para o platô inferior de L3 e superior de L4, correlação substancial entre o platô inferior de L2, platô inferior de L5 e superior de L5. Concluímos que a técnica Dixon apresentou superioridade na detecção do Modic I em relação ao protocolo tradicional, assim como permitiu detectar médias mais altas da espessura das alterações no osso subcondral. Também conclui-se que houve boa reprodutibilidade intra-observador e correlação interobservador variável entre os platôs vertebrais analisados / Signal changes in the subchondral bone of the vertebral bodies were first described by Modic, correlating the spectrum of bone marrow changes in the vertebral body to degenerative disc diseases. Modic type I represents the change of edema type signal, while Modic II represents the change of signal with liposubstitution pattern and Modic III represents signal change related to bone sclerosis. The main objective of this study was to evaluate if there is difference in the detection of Modic classification in the lumbar spine comparing the Dixon technique with the traditional protocol. We evaluated the intraobserver and interobserver correlation as a secondary objective. The study was performed retrospectively, including patients whose magnetic resonance imaging (MRI) was performed at the Ribeirão Preto Diagnostic Center (CEDIRP). Two radiologist physicians independently classified the Modic type endplate changes allowing an interobserver evaluation and one of the radiologists performed a second analysis of the exams making possible an intraobserver evaluation. The results showed that the Dixon technique presented superiority in the detection of Modic I in all the analyzes and also presented higher averages of the thickness of the alterations in the subchondral bone. There were moderate and substantial intraobserver correlations in the traditional protocol and substantial to high Dixon technique. The interobserver correlation was moderate in the evaluation of this type of alteration for the upper and lower plateau of L3 and inverse and nonsignificant for the upper plateau of L5 using the traditional protocol. On the other hand, the interobserver correlation with the Dixon technique showed perfect agreement among the observers in the evaluation of type of signal change in the subchondral bone of the lower plateau of L1, an inverse correlation for the lower plateau of L3 and higher of L4, a substantial correlation between the lower plateau of L2, lower of L5 and higher of L5. We conclude that the Dixon technique presented superiority in the detection of Modic I compared with the traditional protocol, as well as allowed the detection higher averages of the thickness of alterations in the subchondral bone. It was also concluded that there was good intraobserver reproducibility and a variable interobserver correlation between the vertebral plateaus analyzed
116

"Análise da sensibilidade e reprodutibilidade da escala de Basso, Beattie e Bresnahan (BBB) em ratos Wistar" / Analysis of sensitivity and reproducibility of the Basso,Beattie and Bresnahan (BBB) Scale on rats

Molina, Alessandra Eira Iague Sleiman 21 August 2006 (has links)
Procurou-se avaliar a sensibilidade e a reprodutibilidade da escala funcional de Basso, Beattie e Bresnahan (escala BBB) para a avaliação da capacidade locomotora dos ratos após lesão medular. A escala BBB é uma medida preditiva baseada em critérios observacionais específicos da movimentação do animal durante a marcha e que atribui uma pontuação seqüencial e acumulativa correspondente aos critérios pré-estabelecidos satisfeitos. Submeteram-se 30 ratos Wistar à laminectomia e à contusão medular leve, moderada e grave produzida pelo equipamento computadorizado de impacto por queda de peso desenvolvido pela Universidade de Nova Iorque (NYU Weight-Drop Impactor). No 28º dia após a contusão medular, cada rato foi colocado numa caixa transparente (80x80x30cm), com o fundo e a parede posterior forrados com material antiderrapante escuro e estimulado a se movimentar. A movimentação de cada rato foi registrada, simultaneamente, por 3 câmeras digitais e, após a edição, cópias idênticas dos filmes foram encaminhadas à seis pesquisadores independentes, sem a informação sobre a gravidade da lesão correspondente de cada rato, para a determinação da capacidade locomotora segundo a escala funcional de Basso, Beattie e Bresnaham. Verificou-se a sensibilidade do método para detectar diferenças entre os resultados das patas do lado esquerdo e direito, entre os ratos submetidos a lesões leves, moderadas e graves e entre os avaliadores através de comparações dos resultados funcionais e a reprodutibilidade através de testes de correlação. A escala BBB apresenta: a) nas lesões leves sensibilidade satisfatória e elevada reprodutibilidade; b) nas lesões moderadas a sensibilidade é insatisfatória e a reprodutibilidade satisfatória, porém moderada; c) sensibilidade insatisfatória e redução da reprodutibilidade. / An assessment of the sensitivity and reproducibility of the Basso, Beattie and Bresnahan functional scale (BBB scale) was carried out, to evaluate the locomotion capacity following spinal cord injury. The BBB scale is a predictive procedure based on specific observational criteria of the locomotion of the animal under way, which attributes a sequential and cumulative score corresponding to satisfied pre-established criteria. 30 Wistar rats underwent laminectomy and light, moderate and severe spinal cord injury generated by the computerized equipment of impact through weight-drop developed by the University of New York (NYU Weight-Drop Impactor). At day 28 following the spinal cord injury, each rat was placed into a transparent box (80x80x30cm), with the bottom and the posterior wall lined with dark anti-slip material, and stimulated to move. The locomotion of each rat was recorded, simultaneously, by 3 digital cameras and, after editing, identical copies of the films were sent to six independent researchers, with no information regarding the severity of the injure in each rat, for determining the locomotory capabilities according to the Basso, Beattie and Bresnahan scale. The sensitivity of the method was verified for detecting differences between the results obtained from the left and right-side paws, among the rats subjected to light, moderate and severe injuries and among the evaluators through comparisons of the functional results and the reproducibility through correlation tests.
117

Desenvolvimento e validação de uma ferramenta computacional para mensuração das curvaturas da coluna vertebral. / Development and validation of computational tool for measuring of curves of the spine

Suaide, André Luis Alarcon do Passo 13 November 2008 (has links)
A coluna vertebral desempenha um papel importante no dia a dia oferecendo suporte necessário à movimentação do tronco além da locomoção do ser humano, sendo o seu funcionamento diretamente relacionado com a qualidade de vida; sua disposição e articulação das vértebras proporcionam estabilidade e flexibilidade à coluna vertebral, atributos necessários para o equilíbrio do ser humano. A hipercifose torácica, hiperlordose lombar e escoliose são as patologias posturais mais comuns e podem ser diagnosticadas pela mensuração do ângulo da curvatura da coluna vertebral. Comumente a radiografia é utilizada como método para a mensuração de tais ângulos, porém, além de ser um método caro, é altamente invasivo por causa da exposição à radiação, por isso não é aconselhado praticá-lo muitas vezes, sendo o acompanhamento do tratamento difícil de ser feito. Há diversos métodos não invasivos, porém não combinam praticidade, baixo custo e análise tridimensional da curvatura, sendo eficazes em mensurar apenas a coluna no plano sagital. Por esses motivos, para o uso clínico, o profissional de saúde necessita de um método barato, confiável, prático, que atenda suas necessidades e não invasivo para a mensuração da curvatura da coluna vertebral. O objetivo desse trabalho foi desenvolver e validar com a Cinemetria composto de cinco câmeras infravermelhas uma ferramenta computacional (LoB Analytics) para mensurar esse ângulos, o software terá código aberto e uso gratuito. A média de todos os ângulos obtida pela Cinemetria foi de 43,4±18,5º e pelo LoB Analytics foi de 43,9±17,7º, com uma correlação muito forte de 0,98. Foram feitas regressões lineares que confirmaram que ângulos calculados pelo LoB Analytics são tão confiáveis quanto os calculados pela Cinemetria, que é um método bastante utilizado hoje em dia. Os grandes diferenciais do LoB Analytics sobre a Cinemetria são: o seu baixo custo e a praticidade de usá-lo em laboratórios e clínicas. / The spine has an important role day by day offering the necessary flexibility for movement of the trunk besides support and locomotion of humans and being is directly related to the quality of life. The provision and articulation of the vertebrae are responsible for the stability and flexibility of spine attributes necessary for the balance. The thoracic hiper and hypo kyphosis, lumbar hiper and hypo lordosis and scoliosis are the most common postural pathologies and can be diagnosed by measuring the angle of the curvature of the spine. The radiographic method has been the most popular method for such measurement, however, it is an expensive method and also invasive (because its exposure to radiation), it is not the method more indicated to be used repeatedly, being the monitoring of treatment difficult to be done. There are several noninvasive methods but they do not combine practicality, low cost and three-dimensional analysis of the spine curvature, and they are effective in measuring the spine only in the sagittal plane. For these reasons, the health professional needs a method that has low cost, reliable, practical and noninvasive methods for measurement of the curvature of the spine. The goal of this work was develop and validate, with motion capture system (Cinemetria), a computational tool for this measurement (LoB Analytics), which will be free and open source. The mean of all Cinemetria angles was 43,9±18,5º and LoB Analytics angles was 43,9±17,7, with a very strong correlation coefficient of 0,98. Linear regressions confirmed that LoB Analytics angles are as reliable as those calculated by Cinemetria, which is a method widely used today. The differentials of LoB Analytics on Cinemetria are: low cost and practicality of using it in laboratories and clinics.
118

Caracterização da rigidez póstero-anterior da coluna lombar in vivo: uma análise biomecânica

Santos, Rodrigo Silva e [UNESP] 02 1900 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:34:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-02Bitstream added on 2014-06-13T20:45:40Z : No. of bitstreams: 1 santos_rs_dr_guara.pdf: 2269496 bytes, checksum: 15510607497762c601558887cb80984f (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A mobilização póstero-anterior consiste numa técnica de terapia manual que tem a finalidade de detectar alterações no padrão normal e na amplitude dos movimentos das articulações intervertebrais em pacientes com lombalgia. Mecanicamente, define-se como uma sobrecarga de inclinação de três pontos e, embora, o procedimento de aplicação desta técnica tenha sido descrito, caracteriza-se por um método subjetivo de análise clínica. No sentido de buscar um melhor esclarecimento acerca dos aspectos mecânicos envolvidos na mobilização póstero-anterior, foi desenvolvido um dispositivo eletromecânico, para análise in vivo da rigidez segmentar póstero-anterior da coluna lombar. Tal aparato compõe-se essencialmente de um suporte de sustentação com dois graus de liberdade (x, y) integrado a um motoredutor de corrente contínua acoplado a um pino guia e fixo a uma maca especialmente adaptada. Permite o controle preciso da intensidade, direção e velocidade da força aplicada, além da mensuração da amplitude do deslocamento intervertebral. Os resultados demonstraram que o instrumento desenvolvido apresenta a possibilidade de uma análise quantitativa acurada, em termos de rigidez segmentar na coluna lombar, indicando um grau de confiabilidade significativo para os dados obtidos em testes de repetibilidade (ICC > 0,80). Foi demonstrado haver diferença estatisticamente significativa (p<0,05) entre os valores médios dos graus de rigidez dos níveis vertebrais analisados (LI, LII, LIII, LIV e LV) em 10 sujeitos avaliados. Deste modo, é importante que seja questionado o conceito da comparação do grau de rigidez entre os diferentes níveis vertebrais, num mesmo sujeito, para critério de diagnóstico. / The posteroanterior motion test consists of a manual therapy technique to assess the range of motion and stiffness parameters of intervertebral joints in subjects with low back pain. Mechanically, it is defined as a three point bending loading. Although, has been described the technique procedure of the posteroanterior motion test, it is characterized by a subjective method of clinical analysis. In the quest to better understand concerning the mechanical aspects of posteroanterior motion test was developed a mechanical device for assessment the response of the lumbar spine to a posteroanterior pressure in vivo. Essentially, such apparatus is composed of a sustentation support with two degrees of freedom (x, y) fixed to a couch especially adapted and integrated to a continuous current motor and a guidance pin. It allows variables such as force, frequency of oscillation and displacement to be precisely controlled. The results demonstrated high reliability (ICC > 0,80) of the measures obtained in test and re-test. So, the instrument developed presents the prospect of an accuracy quantitative analysis of intervertebral posteroanterior stiffness in lumbar spine. There was statistically significant difference (p<0,05) amongst the means of stiffness coefficients of the vertebral levels analyzed (LI, LII, LIII, LIV and LV) in 10 subjects evaluated. Therefore, its is important to be questioned the concept of the comparison of stiffness in different vertebral levels in a same subject for diagnosis criterion.
119

"Análise da sensibilidade e reprodutibilidade da escala de Basso, Beattie e Bresnahan (BBB) em ratos Wistar" / Analysis of sensitivity and reproducibility of the Basso,Beattie and Bresnahan (BBB) Scale on rats

Alessandra Eira Iague Sleiman Molina 21 August 2006 (has links)
Procurou-se avaliar a sensibilidade e a reprodutibilidade da escala funcional de Basso, Beattie e Bresnahan (escala BBB) para a avaliação da capacidade locomotora dos ratos após lesão medular. A escala BBB é uma medida preditiva baseada em critérios observacionais específicos da movimentação do animal durante a marcha e que atribui uma pontuação seqüencial e acumulativa correspondente aos critérios pré-estabelecidos satisfeitos. Submeteram-se 30 ratos Wistar à laminectomia e à contusão medular leve, moderada e grave produzida pelo equipamento computadorizado de impacto por queda de peso desenvolvido pela Universidade de Nova Iorque (NYU Weight-Drop Impactor). No 28º dia após a contusão medular, cada rato foi colocado numa caixa transparente (80x80x30cm), com o fundo e a parede posterior forrados com material antiderrapante escuro e estimulado a se movimentar. A movimentação de cada rato foi registrada, simultaneamente, por 3 câmeras digitais e, após a edição, cópias idênticas dos filmes foram encaminhadas à seis pesquisadores independentes, sem a informação sobre a gravidade da lesão correspondente de cada rato, para a determinação da capacidade locomotora segundo a escala funcional de Basso, Beattie e Bresnaham. Verificou-se a sensibilidade do método para detectar diferenças entre os resultados das patas do lado esquerdo e direito, entre os ratos submetidos a lesões leves, moderadas e graves e entre os avaliadores através de comparações dos resultados funcionais e a reprodutibilidade através de testes de correlação. A escala BBB apresenta: a) nas lesões leves sensibilidade satisfatória e elevada reprodutibilidade; b) nas lesões moderadas a sensibilidade é insatisfatória e a reprodutibilidade satisfatória, porém moderada; c) sensibilidade insatisfatória e redução da reprodutibilidade. / An assessment of the sensitivity and reproducibility of the Basso, Beattie and Bresnahan functional scale (BBB scale) was carried out, to evaluate the locomotion capacity following spinal cord injury. The BBB scale is a predictive procedure based on specific observational criteria of the locomotion of the animal under way, which attributes a sequential and cumulative score corresponding to satisfied pre-established criteria. 30 Wistar rats underwent laminectomy and light, moderate and severe spinal cord injury generated by the computerized equipment of impact through weight-drop developed by the University of New York (NYU Weight-Drop Impactor). At day 28 following the spinal cord injury, each rat was placed into a transparent box (80x80x30cm), with the bottom and the posterior wall lined with dark anti-slip material, and stimulated to move. The locomotion of each rat was recorded, simultaneously, by 3 digital cameras and, after editing, identical copies of the films were sent to six independent researchers, with no information regarding the severity of the injure in each rat, for determining the locomotory capabilities according to the Basso, Beattie and Bresnahan scale. The sensitivity of the method was verified for detecting differences between the results obtained from the left and right-side paws, among the rats subjected to light, moderate and severe injuries and among the evaluators through comparisons of the functional results and the reproducibility through correlation tests.
120

Desenvolvimento e validação de uma ferramenta computacional para mensuração das curvaturas da coluna vertebral. / Development and validation of computational tool for measuring of curves of the spine

André Luis Alarcon do Passo Suaide 13 November 2008 (has links)
A coluna vertebral desempenha um papel importante no dia a dia oferecendo suporte necessário à movimentação do tronco além da locomoção do ser humano, sendo o seu funcionamento diretamente relacionado com a qualidade de vida; sua disposição e articulação das vértebras proporcionam estabilidade e flexibilidade à coluna vertebral, atributos necessários para o equilíbrio do ser humano. A hipercifose torácica, hiperlordose lombar e escoliose são as patologias posturais mais comuns e podem ser diagnosticadas pela mensuração do ângulo da curvatura da coluna vertebral. Comumente a radiografia é utilizada como método para a mensuração de tais ângulos, porém, além de ser um método caro, é altamente invasivo por causa da exposição à radiação, por isso não é aconselhado praticá-lo muitas vezes, sendo o acompanhamento do tratamento difícil de ser feito. Há diversos métodos não invasivos, porém não combinam praticidade, baixo custo e análise tridimensional da curvatura, sendo eficazes em mensurar apenas a coluna no plano sagital. Por esses motivos, para o uso clínico, o profissional de saúde necessita de um método barato, confiável, prático, que atenda suas necessidades e não invasivo para a mensuração da curvatura da coluna vertebral. O objetivo desse trabalho foi desenvolver e validar com a Cinemetria composto de cinco câmeras infravermelhas uma ferramenta computacional (LoB Analytics) para mensurar esse ângulos, o software terá código aberto e uso gratuito. A média de todos os ângulos obtida pela Cinemetria foi de 43,4±18,5º e pelo LoB Analytics foi de 43,9±17,7º, com uma correlação muito forte de 0,98. Foram feitas regressões lineares que confirmaram que ângulos calculados pelo LoB Analytics são tão confiáveis quanto os calculados pela Cinemetria, que é um método bastante utilizado hoje em dia. Os grandes diferenciais do LoB Analytics sobre a Cinemetria são: o seu baixo custo e a praticidade de usá-lo em laboratórios e clínicas. / The spine has an important role day by day offering the necessary flexibility for movement of the trunk besides support and locomotion of humans and being is directly related to the quality of life. The provision and articulation of the vertebrae are responsible for the stability and flexibility of spine attributes necessary for the balance. The thoracic hiper and hypo kyphosis, lumbar hiper and hypo lordosis and scoliosis are the most common postural pathologies and can be diagnosed by measuring the angle of the curvature of the spine. The radiographic method has been the most popular method for such measurement, however, it is an expensive method and also invasive (because its exposure to radiation), it is not the method more indicated to be used repeatedly, being the monitoring of treatment difficult to be done. There are several noninvasive methods but they do not combine practicality, low cost and three-dimensional analysis of the spine curvature, and they are effective in measuring the spine only in the sagittal plane. For these reasons, the health professional needs a method that has low cost, reliable, practical and noninvasive methods for measurement of the curvature of the spine. The goal of this work was develop and validate, with motion capture system (Cinemetria), a computational tool for this measurement (LoB Analytics), which will be free and open source. The mean of all Cinemetria angles was 43,9±18,5º and LoB Analytics angles was 43,9±17,7, with a very strong correlation coefficient of 0,98. Linear regressions confirmed that LoB Analytics angles are as reliable as those calculated by Cinemetria, which is a method widely used today. The differentials of LoB Analytics on Cinemetria are: low cost and practicality of using it in laboratories and clinics.

Page generated in 0.021 seconds