• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 118
  • 13
  • 1
  • Tagged with
  • 133
  • 133
  • 109
  • 105
  • 31
  • 20
  • 19
  • 18
  • 18
  • 18
  • 16
  • 15
  • 14
  • 14
  • 14
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
121

Método simplificado versus convencional de confecção de próteses totais para aplicação na saúde pública. Parte II: qualidade de vida associada à saúde bucal, satisfação do paciente, qualidade das próteses / Simplified versus conventional method for complete denture fabrication for application in public health. Part II: oral health related quality of life, patient satisfaction and denture quality

Romulo Rocha Regis 19 July 2012 (has links)
Métodos convencionais para a confecção de próteses totais envolvem uma série de procedimentos técnicos complexos. No entanto, métodos simplificados podem ser tão efetivos quanto os convencionais, porém com menor gasto de tempo e recursos, sem representar prejuízos aos usuários. Assim, o objetivo deste estudo foi comparar um método simplificado de confecção de próteses totais a outro convencional, tendo como variáveis a qualidade de vida associada à saúde bucal (QVSB), a satisfação dos pacientes e qualidade das próteses. A amostra foi formada por pacientes desdentados solicitando tratamento com próteses totais bimaxilares. Os participantes foram divididos aleatoriamente em dois grupos: Grupo S (n=19), que recebeu próteses confeccionadas por um método simplificado, e Grupo C (n=20), que recebeu próteses confeccionadas de forma convencional. Antes dos tratamentos e após 3 e 6 meses da instalação das próteses, a QVSB foi avaliada por meio do questionário OHIPEDENT e a satisfação dos usuários por meio de um questionário específico e escala visual analógica. A qualidade das próteses foi avaliada após 3 meses por um especialista. Os dois grupos foram comparados por meio de testes adequados à distribuição dos dados (α=5%). A QVSB e qualidade das próteses foram similares nos grupos C e S. Não houve diferença entre os grupos quanto à satisfação geral avaliada pelos dois questionários. Diferenças em relação à satisfação dos usuários com aspectos específicos das próteses só ocorreram na avaliação dos 3 meses, não persistindo na segunda avaliação. Conclui-se que métodos simplificados são capazes de produzir próteses totais de qualidade comparável às geradas por métodos convencionais, influenciando a QVSB e a satisfação de seus usuários de forma similar. / Complete denture fabrication involves a series of complex technical procedures. Nevertheless, simplified methods may be as effective as conventional ones albeit the lesser use of time and resources, without disadvantage to the denture wearer. Thus, the purpose of this study was to compare a simplified method for complete denture fabrication to a conventional protocol in a randomized controlled trial in terms of oral health quality of life (OHRQoL), patient satisfaction and denture quality. A sample was created by edentulous patients requesting treatment with maxillary and mandibular complete dentures. Participants were randomly allocated into two study groups. Group S (n=19), which received dentures fabricated by a simplified method, and Group C (n=20), which received conventionally fabricated dentures. Before the interventions and after 3 and 6 months following insertion, OHRQoL was evaluated by means of OHIP-EDENT questionnaire and patient satisfaction was analyzed by a visual analogue scale and a specific questionnaire. Denture quality was assessed 3 months after delivery by a prosthodontist. Groups were compared by means of statistical tests suitable for the distribution of data (α=5%). Groups presented no difference for OHRQoL, denture quality and patient general satisfaction. Differences regarding to patient satisfaction with specific aspects of the dentures were found after 3 months, but were insignificant at 6 months. It was concluded that the simplified method is able to produce complete dentures of a quality comparable to those produced by the conventional protocol, influencing the OHQoL and satisfaction of their wearers similarly
122

Avaliação clínica da estabilidade dimensional de próteses totais submetidas à desinfecção por microondas /

Basso, Michael Frederico Manzolli. January 2009 (has links)
Resumo: A energia por microondas tem sido recomendada para desinfetar próteses totais. Entretanto, os ciclos de desinfecção podem afetar a estabilidade dimensional das bases de próteses. Assim, o objetivo deste estudo clínico foi avaliar o efeito de dois protocolos de desinfecção por microondas na estabilidade dimensional de próteses totais, analisando a estabilidade dimensional linear, o percentual de força oclusal obtido a partir dos contatos oclusais cêntricos e as ocorrências clínicas. Foram confeccionadas próteses totais para quarenta pacientes totalmente edêntulos. Todas as próteses foram prensadas com a resina Lucitone 550. Após a colocação, aguardou-se 30 dias para submeter as próteses às condições experimentais como a seguir: Grupo 1 (G1)- 20 pacientes tiveram as próteses maxilares submetidas a desinfecção por microondas (650 W / 3 minutos), uma vez por semana, durante 4 semanas. Grupo 2 (G2)- 20 pacientes tiveram as próteses maxilares submetidas a desinfecção por microondas (650 W / 3 minutos), três vezes por semana, durante 4 semanas. Para avaliar a estabilidade dimensional linear, mensurações foram realizadas entre quatro pontos de referência (primeiros pré-molares e segundos molares bilateralmente) antes da primeira desinfecção por microondas (baseline) e após cada semana de desinfecção. Um software foi utilizado para mensurar as distâncias entre os pontos de referência a partir de fotografias padronizadas. As dimensões médiolateral e anteroposterior e a área foram calculadas. Os dados foram analisados pelos testes ANOVA two-way, Tukey e t-Student (_=0,05). O sistema T-Scan III foi utilizado para avaliar o percentual de força oclusal obtido a partir dos contatos oclusais cêntricos. Os contatos oclusais cêntricos foram capturados, antes da primeira desinfecção por microondas (baseline) e após cada semana de desinfecção, por meio... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Microwave energy has been recommended for disinfecting complete dentures. However, the microwave disinfection cycles may affect the dimensional stability of denture bases. Therefore, the purpose of this clinical study was to evaluate the effect of two microwave disinfection protocols on the dimensional stability of complete dentures, analyzing the linear dimensional stability, the percent occlusal force obtained from centric occlusal contacts and the clinical events. Complete dentures were constructed for forty totally edentulous patients. All dentures were conventionally processed with heat-polymerized acrylic resin (Lucitone 550). After insertion of complete dentures, it was expected 30 days to submit the dentures to the experimental conditions as follows: Group 1 (G1)- 20 patients had the maxillary complete dentures submitted to microwave disinfection (650 W/ 3 minutes), once a week, for four weeks. Group 2 (G2)- 20 patients had the maxillary complete dentures submitted to microwave disinfection (650 W/ 3 minutes), three times a week, for four weeks. To evaluate the linear dimensional stability, measurements were taken across four reference points (first premolars and second molars bilaterally) before of first microwave disinfection (baseline) and after each week of disinfection. Software was used to measure distances between reference points from standardized photographs. Mediolateral and anteroposterior dimensions and area between reference points were calculated. The dimensional data obtained were analyzed using two-way ANOVA, Tukey test and t test (_ = .05). To evaluate the percent occlusal force obtained from centric occlusal contacts, the T-Scan III system was used. The centric occlusal contacts were measured, before of first microwave disinfection (baseline) and after each week of disinfection, using pressure-sensitive sheets and studied in T-Scan software. The occlusal data... (Complete abstract click electronic access below) / Orientador: Eunice Teresinha Giampaolo / Coorientador: Marco Antonio Compagnoni / Banca: Raphael Freitas de Souza / Banca: Claudia Helena Lovato da Silva / Banca: Ana Claudia Pavarina / Banca: João Neudenir Arioli Filho / Doutor
123

Método simplificado versus convencional de confecção de próteses totais para aplicação na saúde pública. Parte III: avaliação da função mastigatória / Simplified versus conventional method for complete denture fabrication for application in public health. Part III: Assessment of masticatory function

Tatiana Ramirez Cunha 13 December 2011 (has links)
Métodos convencionais para a confecção de próteses totais envolvem uma série de procedimentos técnicos complexos. No entanto, métodos simplificados podem ser tão efetivos quanto os convencionais, porém é importante que a mastigação não sofra influências deletérias. Assim, o objetivo deste estudo foi comparar um método simplificado de confecção de próteses totais a outro convencional, tendo como variáveis a performance e a habilidade mastigatórias. A amostra foi formada por pacientes desdentados solicitando tratamento com próteses totais duplas. Os participantes foram divididos aleatoriamente em dois grupos: Grupo S (n=17), que recebeu próteses confeccionadas por um método simplificado, e Grupo C (n=18), que recebeu próteses confeccionadas de forma convencional. Após 3 meses da instalação das próteses, a performance mastigatória foi avaliada por um método colorimétrico, utilizando duas biocápsulas como alimento teste, após 20 e 40 ciclos mastigatórios, e a habilidade mastigatória dos participantes foi avaliada por meio de questionário (Questionário HM) e escala visual analógica (EVA). Foi feita referência dos resultados a um grupo de participantes dentados, Grupo DN (n=17). Os três grupos foram comparados por meio de testes adequados à distribuição dos dados (α=5%). A performance mastigatória foi similar nos grupos C e S e representou 31% daquela encontrada no grupo DN. A habilidade mastigatória foi semelhante para S e C independente do método de análise, sendo que algumas questões do questionário HM, analisadas isoladamente, tiveram maior ocorrência de respostas favoráveis para o primeiro. Conclui-se que métodos simplificados de confecção de próteses totais são capazes de reabilitar a mastigação de maneira comparável ao método convencional, tanto fisiologicamente como segundo as percepções do paciente. / Complete denture fabrication involves a series of complex technical procedures. Nevertheless, simplified methods may be as effective as conventional ones and mastication should not be further impaired. Therefore, this study aimed to compare a simplified method and a conventional protocol for complete denture fabrication, in terms of masticatory performance and ability. A sample was formed by edentulous patients requesting treatment with maxillary and mandibular complete dentures. Participants were randomly allocated into two groups: Group S (n=17), which received dentures fabricated by a simplified method, and Group C (n=18), which received conventionally fabricated dentures. After 3 months following insertion, masticatory performance was evaluated by means of a colorimetric assay based on chewing two capsules as test food during 20 and 40 cycles. Masticatory ability was assessed by means of a questionnaire (HM) with dichotomous answers and a single question answered by means of a visual analogue scale (VAS). A third group (DN, n=17) formed by dentate volunteers served as an external comparator. Results for the three groups were compared by means of statistical tests suitable for the distribution of data (α=5%). Groups C and S presented similar masticatory performance which corresponded to 31% of group DN. Results for masticatory ability showed similarity between S and C, regardless of the assessment method, though some isolate items of the HM questionnaire showed more favorable results for the first group. It can be concluded that simplified methods for complete denture fabrication are able to restore masticatory function to a level comparable to the conventional protocol, physiologically and according to patient perceptions.
124

Efeito antimicrobiano residual e citotoxidade in vitro de resina acrílica para base de prótese após imersão prolongada em agentes de limpeza / In vitro residual antimicrobial effect and cytotoxicity of acrylic resin base prosthesis after long-term immersion in cleaning agents

Andréa Lemos Falcão Procópio 15 May 2015 (has links)
O presente estudo in vitro objetivou avaliar a longo prazo o potencial antimicrobiano residual e a citotoxicidade de soluções químicas de limpeza de prótese quando incorporadas à resina acrílica termopolimerizável após sucessivos ciclos de imersão noturna diária. Discos (10mm x 1mm) de resina acrílica termopolimerizável para base de prótese (Lucitone 550) foram submetidos a três ciclos diários de desinfecção (8h/cada) em hipoclorito de sódio a 1% (NaClO), digluconato de clorexidina a 2% (CLX) ou água destilada (controle) durante 91 (T91) ou 183 dias (T183), simulando o período de 9 meses ou 1,5 ano de imersão noturna diária realizada pelo paciente. Inicialmente, foi utilizado o método de concentração inibitória mínima em caldo para determinar o possível efeito residual (incorporação) das soluções à resina acrílica. Metade dos discos imersos em cada agente de limpeza em um dos tempos de imersão (n=5) foi inoculada (1x107cels/mL) com um dos patógenos associados à estomatite protética: Candida albicans (Ca) e Staphylococcus aureus (Sa). Os discos foram incubados a 37oC para análise em espectrofotômetro após 24h, 7 e 14 dias. Os valores de absorbância foram convertidos em porcentagens de inibição microbiana. Confirmada a ação antimicrobiana residual dos agentes de limpeza incorporados à resina acrílica, foi então analisada sua citotoxicidade in vitro sobre fibroblastos gengivais humanos (L929). Os efeitos citotóxicos foram avaliados por meio do ensaio colorimétrico MTT [brometo de 3-(4,5-dimetiltiazol-2-yl)-2,5-difeniltetrazólio] para a determinação da viabilidade celular, após as células serem expostas por 24h às amostras de cada condição experimentais (n=18) previamente imersas em uma das soluções por um dos períodos avaliados (T91 ou T183). A citotoxicidade foi determinada com base na atividade mitocondrial em relação a corpos de prova não submetidos à imersão nas soluções testadas. Os resultados do ensaio do MTT foram analisados estatisticamente por ANOVA-1 fator seguida pelo teste post-hoc de Tukey HSD (a=0,05). Para os períodos T91 e T183, não houve inibição microbiana com a imersão em água (controle) em até 14 dias de incubação. A CLX inibiu progressivamente o crescimento microbiano ao longo dos 14 dias para ambos os períodos de imersão (Ca: 19 a 73,58%; Sa: 0 a 87,08%), sendo observada maior ação antimicrobiana em T183. O NaClO apresentou discreta inibição microbiana apenas no período de 14 dias tanto em T91 (Ca: 0%; Sa: 2,70%) quanto em T183 (Ca: 8,50%; Sa: 15,08%). De acordo com os resultados do teste de MTT, as soluções químicas de limpeza testadas apresentaram uma redução significativa da viabilidade celular quando comparado às células controles propagadas apenas em meio de cultura (p<0,002). A CLX resultou na menor viabilidade celular em ambos os períodos de imersão (p<0,018). As amostras de resina acrílica imersas em água ou NaClO em T91 e T183 apresentaram viabilidade celular estatisticamente similar às amostras não imersas (p>0,05). Pode-se concluir que a CLX incorporada à resina acrílica para base de prótese apresentou um efeito antimicrobiano residual em ambos os períodos de imersão noturna, o que não foi observado com o NaClO. Por outro lado, a CLX residual resultou em efeito intensamente citotóxico aos fibroblastos gengivais humanos quando comparada ao NaClO e à agua destilada, que se apresentaram discretamente citotóxicos. Esses resultados sugerem precaução na seleção de agentes de limpeza para prótese como meio de prevenção e tratamento adjunto da estomatite protética, pois mesmo em concentrações baixas, recomendadas para imersão noturna, podem apresentar algum grau de toxicidade às mucosas de suporte protético. / This in vitro study aimed to evaluate the long-term residual antimicrobial activity and cytotoxicity of chemical denture cleansers incorporated into a heat-polymerized acrylic resin after successive cycles of daily overnight soaking. Discs (10mm x 1mm) were prepared from heat-polymerized acrylic resin (Lucitone 550) and submitted to three daily immersion (8h/each) in 1% sodium hypochlorite (NaClO), chlorhexidine digluconate 2% (CHX) or distilled water (control) for 91 days (T91) or 183 days (T183), simulating the period of 9 months or 1.5 year of nocturnal immersion performed by the patient. Initially, the method of minimum inhibitory concentration in broth was used to determine the possible residual effect (incorporation) of the acrylic resin solution. Half of the disks immersed in each cleaning agent for one of the period immersion (n=5) was inoculated (1x107cells/mL) with pathogens associated with denture stomatitis: Candida albicans (Ca) or Staphylococcys aureus (Sa). The disks were incubated at 37oC for analysis in a spectrophotometer after 24h, 7 and 14 days. The absorbance values were expressed as percentages of microbial inhibition. Confirmed the residual antimicrobial action of cleaning agents incorporated into the acrylic resin, its cytotoxicity was analyzed in vitro on human gingival fibroblasts (L929). Cytotoxic effects were evaluated by the colorimetric assay MTT [3- (4,5- dimethylthiazol-2-yl) -2,5-diphenyl tetrazolium bromide] to determine cellular viability after the cells were exposed for 24h to the samples of each experimental condition (n=18) previously immersed in one of the solutions for the evaluation periods (T91 or T183). Cytotoxicity was determined based on mitochondrial activity compared to the specimens not subjected to immersion in the solutions. The MTT assay results were 1-way ANOVA followed by Tukey\'s HSD post-hoc test (a=0.05). For the periods T91 and T183, no microbial inhibition was observed with immersion in water (control) for up to 14 days of incubation. The CHX progressively inhibited microbial growth over the 14 days for both immersion times (Ca: 19 to 73.58%, Sa: 0 to 87.08%); with greater antimicrobial activity in T183. The NaClO showed a slight microbial inhibition only in the 14-day period in both T91 (Ca: 0%; Sa: 2.70%) and T183 (Ca: 8.50%; Sa: 15.08%). According to the results of the MTT assay, the chemical cleaning solutions tested showed a significant reduction in cell viability when compared to the control cells propagated in normal culture medium (p<0.002). The CHX resulted in the lowest cell viability in both immersion periods (p<0.018). The acrylic samples immersed in water or NaClO in T91 and T183 showed cell viability statistically similar to nonimmersed samples (p>0.05). CHX incorporated into the acrylic resin denture base had a residual antimicrobial effect on both immersion periods, which was not observed with NaClO. On the other hand, the residual CHX were severely cytotoxic to human gingival fibroblasts compared to NaClO and distilled water which were slightly cytotoxic. These results suggest caution in selecting denture cleaning agents as a method of prevention and adjunct treatment of denture stomatitis because even at low concentrations recommended for overnight immersion, they may exhibit some degree of toxicity to the denture bearing mucosa.
125

Avaliação das guias condilar e incisal em função da curva de compensação e da altura das cúspides - Releitura das Leis de Articulação de Hanau / Evaluation of condylar guidance and incisal guidance according to the compensating curve and cusp heights. A review of Hanaus laws of articulation

Roger Nishyama 19 April 2011 (has links)
Este estudo teve como objetivo avaliar a variação das guias sagitais (guia condilar e guia incisal), em função do plano de orientação (curvatura e inclinação) e da altura das cúspides, no movimento protrusivo mandibular, in vitro, buscando as relações entre esses fatores, tanto de forma analógica como digital. No estudo analógico foram avaliadas as inclinações das guias condilares, inclinações da guia incisal, proeminência da curva de compensação e inclinação do plano oclusal. Para isso foram utilizados planos de orientação prototipados com a proeminência da curva de compensação pré definidas por calotas de esferas de 7, 8 ou 9 polegadas de diâmetro. Para cada proeminência da curva de compensação haviam 3 inclinações antero-posterior também pré definidas em: planos iniciais, ou planos 0, planos com um aumento da inclinação de 5 graus em relação ao primeiro, ou plano +5, e planos com uma inclinação 5 graus menor que o primeiro, ou plano -5. Com um par planos de orientação montados no articulador não arcon Bio-art EVA Plus ajustou-se as guias condilares e incisal, após isso foi aumentada a inclinação da guia condilar e observadas as alterações necessárias nos outros três fatores, inclinação da guia incisal, proeminência da curva de compensação e inclinação do plano oclusal, cada uma em seu determinado momento, para se restabelecer o ajuste do articulador. Esse procedimento foi repetido alterando-se cada um dos outros 3 fatores gerando assim 6 condições experimentais analógicas. No estudo digital foram avaliadas as inclinações das guias condilares, inclinações da guia incisal, proeminência da curva de compensação, inclinação do plano oclusal e altura das cúspides dos dentes posteriores. Para isso, o articulador Bio-art EVA Plus foi reproduzido no programa Adobe Photoshop CS3 juntamente com os planos de orientação e as simulações de cúspides e de dentes anteriores. Da mesma forma que o estudo analógico iniciou-se com os planos de orientação em posição e o articulador com as guias condilares e guia incisal ajustadas; foi aumentada a inclinação da guia condilar e observado no movimento de protrusão o comportamento dos outros 4 fatores, cada um em um determinado momento, para o restabelecimento da oclusão bilaterla balanceada. Esse procedimento foi repetido com cada um dos outros 4 fatores gerando assim 10 condições experimentais virtuais. Os resultados permitiram concluir que existe uma relação entre a inclinação da guia condilar, inclinação da guia incisal, proeminência da curva de compesação, inclinação da curva de compensação e altura das cúspides, na obtenção da oclusão bilateral balanceada, e esta relação comprova as descritas por Hanau em seus estudos. / The objective of this in vitro study was to evaluate the variation of the saggital guidances (condylar guidance and incisal guidance) according to plane of orientation (prominence and inclination) and cusp heights during mandibular protrusive movements. The relationship between afore mentioned factors were assessed through both analogical and digital methods. In the analogical study, the inclination of condylar guidance and incisal guidance, prominence of compensating curve and the inclination of the occlusal plane were evaluated. In order to do so, prototyped guiding planes with compensating curves prominence pre-defined by spheres of 7, 8 and 9 inches of diameter were used. For each compensating curves prominence, there were also 3 pre-defined antero-posterior inclinations: initial planes (plane 0), planes with a 5-degree inclination increase (plane +5) and planes with a 5-degree inclination decrease (plane -5). A pair of guiding planes was mounted on a non-arcon Bio-art EVA Plus articulator and condylar and incisal guidances were adjusted. As the condylar guidance was increased, the changes necessary to reestablish the articulators adjustment were observed for the other three factors: incisal guidances inclination, prominence of compensating curve and occlusal planes inclination. This procedure was repeated altering each one of the other three factors resulting in 6 analogical experimental conditions. In the digital study, condylar guidance inclination, incisal guidance inclination, compensating curve prominence, occlusal plane inclination and posterior teeths cusp heights were evaluated. In order to do so, the Bio-art EVA Plus articulator, guiding planes and simulations of the cusps and anterior teeth were reproduced in the Adobe Photoshop CS3 program As performed at the analogical study, the guiding planes were put into position and the condylar and incisal guidances were adjusted. The condylar guidance inclination was increased and the changes in the other 4 factors were observed in the protrusive moment so that the bilateral balanced occlusion could be reestablished. This procedure was repeated with each one of the 4 factors resulting in 10 virtual experimental conditions. The results showed that there is a relationship between the condylar guidance inclination, incisal guidance inclination, prominence of the compensating curve and the cusp heights when achieving bilateral balanced occlusion and the results obtained in the current study is in accordance with those obtained by Hanau.
126

Survival and Complications of Single Dental Implants in the Edentulous Mandible Following Immediate or Delayed Loading: A Randomized Controlled Clinical Trial

Kern, M., Att, W., Fritzer, E., Kappel, S., Luthardt, R. G., Mundt, T., Reissmann, D. R., Rädel, M., Stiesch, M., Wolfart, S., Passia, N. 29 October 2019 (has links)
It was the aim of this 24-mo randomized controlled clinical trial to investigate whether the survival of a single median implant placed in the edentulous mandible to retain a complete denture is not compromised by immediate loading. Secondary outcomes were differences in prosthetic complications between the loading principles. Each of the 158 patients who received an implant was randomly assigned to the immediate loading group (n = 81) or the delayed loading group (n = 77). Recall visits were performed 1 mo after implant placement (for only the delayed loading group) and 1, 4, 12, and 24 mo after implant loading. Nine implants failed in the immediate loading group, all within the first 3 mo of implant loading, and 1 implant failed in the delayed loading group prior to loading. Noninferiority of implant survival of the immediate loading group, as compared with the delayed loading group, could not be shown (P = 0.81). Consistent with this result, a secondary analysis with Fisher exact test revealed that the observed difference in implant survival between the treatment groups was indeed statistically significant (P = 0.019). The most frequent prosthetic complications and maintenance interventions in the mandible were retention adjustments, denture fractures, pressure sores, and matrix exchanges. There was only 1 statistically significant difference between the groups regarding the parameter “fracture of the denture base in the ball attachment area” (P = 0.007). The results indicate that immediate loading of a single implant in the edentulous mandible reveals inferior survival than that of delayed loading and therefore should be considered only in exceptional cases (German Clinical Trials Register: DRKS00003730).
127

"Avaliação da alteração dimensional da base de prova permanente da prótese total de resina acrílica ativada termicamente, processada em forno microondas, por meio da imagem digital" / Evaluation of the dimensional alteration according to the permanent proof base for complete denture made of thermally activated acrylic resin, in microwave process, using digital image

Lima, Ana Paula Barbosa de 11 August 2006 (has links)
Foram confeccionados 50 corpos de prova, divididos em 30 próteses totais superiores e 20 bases de provas permanentes, padronizados, para se avaliar a alteração dimensional da base de prova permanente, com dupla polimerização, processada em forno de microondas convencional; base de prova permanente com dupla polimerização, processada no método convencional; e a prótese total em uma única polimerização. Para essa análise, essas próteses foram divididas em 5 grupos: grupo I – prótese total convencional – banho de água (controle); grupo II – base de prova permanente processada convencionalmente; grupo III – base de prova permanente processada em forno de microondas convencional; grupo IV – prótese total superior padronizada com base de prova permanente processada convencionalmente, com as bases do grupo II; grupo V – prótese total superior com base de prova permanente, processada no forno de microondas convencional, com as bases de prova do grupo III. Para avaliar essa alteração foi usado o recurso do scaneamento da região posterior das próteses, “Post-dam", desses corpos de prova. Após esse processo, a imagem capturada foi levada para o programa Photoshop 8.0 determinando a região de avaliação. Após essa seleção, a imagem é acessada no CorelTrace 11 para ser transformada em preto e branco e vetorizada, sendo, então, levada para o CorelDraw 11 para ser feita a medição do espaço da região posterior, entre o modelo e a base de prova/prótese total, para permitir a análise dos valores da alteração dimensional dos corpos de prova em questão, após o processamento. Os resultados mostram que: 1) a diferença da variação média para os lados esquerdo, centro e direito, respectivamente, na ordem de décimos ou centésimos de milímetros, para o grupo IV e I (0,07; 0,08 e 0,09); para o grupo V e I (0,10; 0,32 e 0,25) e para o grupo V e IV (0,17; 0,24 e 0,16) não pode ser considerada relevante clinicamente para afetar o ajuste da prótese na boca e promover a ocorrência de maiores transtornos clínicos; 2) A alteração média das áreas do lado esquerdo e direito para o grupo I, II e IV obtiveram uma homogeneidade na alteração, diferindo os Grupos III e V em relação aos outros, não existindo porém, diferença significante a nível de 5% entre as áreas desses segmentos; 3) A análise da variância do índice da área dos cinco (5) grupos não apresentou resultado significante que desabonasse a utilização de qualquer um dos métodos para a confecção da prótese total. No entanto, mais estudos devem ser realizados com o intuito de se aprimorar o uso do forno de microondas para o processamentos da prótese. / The 50 samples of pattern maxillary complete denture were processed, divided in 30 maxillary complete denture and 20 permanent proof base, to evaluated of dimensional changes in the permanent proof base with twice polymerization, process in microwave oven, to compare with the others two groups, the complete denture with conventional process and the complete denture with permanent proof base with twice polymerization in a conventional process. To evaluated this complete dentures they were divided in 5 groups: group I – conventional complete denture; group II – proof base conventional process; group III – proof base in microwave process; group IV – complete denture using the proof base of the group, with the conventional process and the group; group V – complete denture using the proof base of the group III, microwave process. To evaluated this alteration used the scanner in the “Post-dam", in this samples. After this proceding the image was putting in the Adobe Photoshop 8.0 program to determinate what region was evaluated. After this selection, the image access in the CorelTrace 11 program and transformed in black and white, and after to access in the CorelDraw 11 that was measured the region between the cast and the complete/permanent proof base, to allow the analysis of the values the dimensional alteration of the proof body, after the process. The results show: 1) The linear dimensional alteration the difference mean variation for the left, center and right sides, respectively, it was in decimal order or centesimal of millimeters, for the group IV and I (0,07; 0,08 and 0,09); and for the group V and I were (0,10; 0,32 and 0,25) and for the group V and IV (0,17; 0,24 and 0,16) and it cannot be considered clinically relevant to affect the prosthesis adjustment in the mouth, and promote the occurrence of more clinical disruptions; 2) The dimensional alterations in the areas (left and right side) of the proof bodies of the three groups I, II and IV were uniform, and the groups III and V weren’t homogeneous, but there is not a statically significant difference, about 5%, between the segment left and right areas; 3) The variation of the area index about five groups there is not a statically significant that couldn’t use of the both method to build the complete denture. Although, more studies are important to realize with the objective to improve the use the microwave over to process the denture.
128

Ensaio clínico randomizado de sobredentaduras mandibulares retidas por mini-implantes ou implantes convencionais: análise de parâmetros clínicos e custo / A randomized clinical trial of mandibular overdentures retained by mini or convencional implants: clinical parameters and cost analysis

Vecchia, Maria Paula Della 13 April 2015 (has links)
As próteses do tipo sobredentaduras mandibulares retidas por dois implantes convencionais têm sido consideradas como o tratamento padrão para o edentulismo completo. No entanto, muitos pacientes rejeitam essa modalidade de tratamento devido aos custos e desconforto associados à inserção dos implantes. Os mini-implantes têm grande potencial para a resolução dessas limitações, pois são potencialmente menos custosos que os convencionais e podem ser instalados por meio de técnicas cirúrgicas mais simples. O objetivo deste estudo foi comparar a taxa de sucesso dos implantes e das sobredentaduras, a qualidade das próteses e os custos do tratamento, após instalação de mini-implantes (dois ou quatro) ou de dois implantes convencionais para retenção de sobredentaduras mandibulares, por meio de um ensaio clínico randomizado. Cento e vinte participantes edentados totais (média etária 59,5±8,5 anos) foram alocados aleatoriamente em um dos três grupos conforme o tratamento recebido: (GI) quatro mini-implantes; (GII) dois mini-implantes; e (GIII) dois implantes convencionais (grupo controle). Durante seis meses, as seguintes variáveis de desfecho foram avaliadas: a taxa de sucesso dos implantes e das sobredentaduras (incluindo parâmetros de saúde periimplantar), a qualidade das próteses e custos diretos e indiretos do tratamento. Os grupos foram comparados por meio de ANOVA seguida do teste HSD de Tukey ou Equações de Estimação Generalizadas (EEG) (&alpha;=0,05). A taxa de sobrevivência dos implantes foi diferente entre os grupos avaliados: GI (n=152): 94%; GII (n=84): 84% e GIII (n=80): 99%. Apesar de não haver diferença para os outros critérios de sucesso clínico entre os grupos, GI e GII apresentaram menor índice de placa comparado ao GIII, no baseline e após seis meses. GI teve menos ocorrências de dor ao redor de implantes do que os outros grupos em seis meses. A qualidade das próteses também foi diferente para os tratamentos avaliados; as sobredentaduras mandibulares foram mais estáveis no GI comparado com o GIII, após seis meses de uso, com GII apresentando resultados intermediários. Uma tendência inversa foi observada para a estabilidade da prótese total superior, com resultados discretamente superiores no GIII em relação ao GI. Os gastos com os materiais de consumo e permanentes foram menores para o GII (custo médio: R$ 450,67), seguido pelo GI (R$ 778,92), e GIII (R$ 856,44). Os grupos não apresentaram diferenças significantes estatística ou clinicamente para nenhum outro critério avaliado. Concluiu-se que as sobredentaduras mandibulares retidas por quatro mini-implantes são tão eficazes quanto aquelas retidas por dois implantes convencionais. No entanto, as sobredentaduras mandibulares retidas por dois mini-implantes foram menos eficazes, devido à baixa taxa de sucesso dos implantes para este tratamento. / Mandibular overdentures retained by two conventional implants have been considered as the standard of care for complete edentulism. However, many patients refuse that treatment modality due to associated costs and post-surgical discomfort. Mini-implants are possibly able to overcome those limitations, due to their potentially lower costs and a relatively uncomplicated surgical technique. This study aimed to compare the success rate of implants and overdentures, denture quality and treatment costs, following the insertion of mini-implants (two or four) or two standard-size implants for the retention of mandibular overdentures, by means of a randomized clinical trial. One hundred and twenty edentulous participants (mean age 59.5±8.5 years) were randomly allocated into three groups according to received treatment: (GI) four mini-implants, (GII) two mini-implants, or (GIII) two standard implants. During six months, the following outcomes were evaluated: the success rate of implants and overdentures (including parameters of peri-implant health), denture quality and direct and indirect costs of treatment. Groups were compared by ANOVA followed by Tukey HSD test or Generalized Estimating Equations (GEE) (&alpha;=0.05). Implant survival rate was distinct for the tested groups, as follows: GI (n=152): 94%; GII (n=84): 84%; and GIII (n=80): 99%. Although groups were similar for other criteria of clinical success, GI and GII presented lower plaque index compared to GIII, both on baseline and after six months. GI had less occurrences of pain around implants than the other groups in six months. Denture quality was also different for the tested treatments; mandibular overdentures were more stable for GI than for GIII following six months of wearing, with GII presenting intermediate results. This was accompanied by an inverse trend for maxillary dentures stability, with slightly better results with GIII compared to GI. Expenses with consumables and permanent materials were the lowest for GII (average cost: R$ 450.67), followed by GI (R$ 778.92), and GIII (R$ 856.44). Groups did not present statistically or clinically significant differences for other criteria of clinical performance or cost. It was concluded that the mandibular overdentures retained by four mini-implants are as effective as those retained by two conventional implants. Nevertheless, the mandibular overdentures retained by two mini-implants were less effective, due to the lower success rate of implants for such treatment.
129

Ensaio clínico randomizado de sobredentaduras mandibulares retidas por mini-implantes ou implantes convencionais: análise de parâmetros clínicos e custo / A randomized clinical trial of mandibular overdentures retained by mini or convencional implants: clinical parameters and cost analysis

Maria Paula Della Vecchia 13 April 2015 (has links)
As próteses do tipo sobredentaduras mandibulares retidas por dois implantes convencionais têm sido consideradas como o tratamento padrão para o edentulismo completo. No entanto, muitos pacientes rejeitam essa modalidade de tratamento devido aos custos e desconforto associados à inserção dos implantes. Os mini-implantes têm grande potencial para a resolução dessas limitações, pois são potencialmente menos custosos que os convencionais e podem ser instalados por meio de técnicas cirúrgicas mais simples. O objetivo deste estudo foi comparar a taxa de sucesso dos implantes e das sobredentaduras, a qualidade das próteses e os custos do tratamento, após instalação de mini-implantes (dois ou quatro) ou de dois implantes convencionais para retenção de sobredentaduras mandibulares, por meio de um ensaio clínico randomizado. Cento e vinte participantes edentados totais (média etária 59,5±8,5 anos) foram alocados aleatoriamente em um dos três grupos conforme o tratamento recebido: (GI) quatro mini-implantes; (GII) dois mini-implantes; e (GIII) dois implantes convencionais (grupo controle). Durante seis meses, as seguintes variáveis de desfecho foram avaliadas: a taxa de sucesso dos implantes e das sobredentaduras (incluindo parâmetros de saúde periimplantar), a qualidade das próteses e custos diretos e indiretos do tratamento. Os grupos foram comparados por meio de ANOVA seguida do teste HSD de Tukey ou Equações de Estimação Generalizadas (EEG) (&alpha;=0,05). A taxa de sobrevivência dos implantes foi diferente entre os grupos avaliados: GI (n=152): 94%; GII (n=84): 84% e GIII (n=80): 99%. Apesar de não haver diferença para os outros critérios de sucesso clínico entre os grupos, GI e GII apresentaram menor índice de placa comparado ao GIII, no baseline e após seis meses. GI teve menos ocorrências de dor ao redor de implantes do que os outros grupos em seis meses. A qualidade das próteses também foi diferente para os tratamentos avaliados; as sobredentaduras mandibulares foram mais estáveis no GI comparado com o GIII, após seis meses de uso, com GII apresentando resultados intermediários. Uma tendência inversa foi observada para a estabilidade da prótese total superior, com resultados discretamente superiores no GIII em relação ao GI. Os gastos com os materiais de consumo e permanentes foram menores para o GII (custo médio: R$ 450,67), seguido pelo GI (R$ 778,92), e GIII (R$ 856,44). Os grupos não apresentaram diferenças significantes estatística ou clinicamente para nenhum outro critério avaliado. Concluiu-se que as sobredentaduras mandibulares retidas por quatro mini-implantes são tão eficazes quanto aquelas retidas por dois implantes convencionais. No entanto, as sobredentaduras mandibulares retidas por dois mini-implantes foram menos eficazes, devido à baixa taxa de sucesso dos implantes para este tratamento. / Mandibular overdentures retained by two conventional implants have been considered as the standard of care for complete edentulism. However, many patients refuse that treatment modality due to associated costs and post-surgical discomfort. Mini-implants are possibly able to overcome those limitations, due to their potentially lower costs and a relatively uncomplicated surgical technique. This study aimed to compare the success rate of implants and overdentures, denture quality and treatment costs, following the insertion of mini-implants (two or four) or two standard-size implants for the retention of mandibular overdentures, by means of a randomized clinical trial. One hundred and twenty edentulous participants (mean age 59.5±8.5 years) were randomly allocated into three groups according to received treatment: (GI) four mini-implants, (GII) two mini-implants, or (GIII) two standard implants. During six months, the following outcomes were evaluated: the success rate of implants and overdentures (including parameters of peri-implant health), denture quality and direct and indirect costs of treatment. Groups were compared by ANOVA followed by Tukey HSD test or Generalized Estimating Equations (GEE) (&alpha;=0.05). Implant survival rate was distinct for the tested groups, as follows: GI (n=152): 94%; GII (n=84): 84%; and GIII (n=80): 99%. Although groups were similar for other criteria of clinical success, GI and GII presented lower plaque index compared to GIII, both on baseline and after six months. GI had less occurrences of pain around implants than the other groups in six months. Denture quality was also different for the tested treatments; mandibular overdentures were more stable for GI than for GIII following six months of wearing, with GII presenting intermediate results. This was accompanied by an inverse trend for maxillary dentures stability, with slightly better results with GIII compared to GI. Expenses with consumables and permanent materials were the lowest for GII (average cost: R$ 450.67), followed by GI (R$ 778.92), and GIII (R$ 856.44). Groups did not present statistically or clinically significant differences for other criteria of clinical performance or cost. It was concluded that the mandibular overdentures retained by four mini-implants are as effective as those retained by two conventional implants. Nevertheless, the mandibular overdentures retained by two mini-implants were less effective, due to the lower success rate of implants for such treatment.
130

A randomized controlled trial evaluating the quality of life and the sense of coherence in seniors wearing complete conventional dentures or mandibular two-implant overdentures

Jabbour, Zaher 12 1900 (has links)
La supériorité des prothèses mandibulaires retenues par deux implants (IODs) sur les prothèses conventionnelles (CDs) nécessitent d’être éclaircies notamment en rapport à leur influence sur la qualité de vie reliée à la santé bucco-dentaire (OHRQoL) ainsi que sur la stabilité de cet effet de traitement. De plus, l’influence des facteurs psychologiques, tel que le sens de cohérence (SOC), sur l’effet de traitement reste encore inconnue. Le but de cette étude est de déterminer l’amplitude de l’influence du port des IODs et des CDs sur l’OHRQoL et d’évaluer la stabilité de l’effet de traitement dans le temps, tout en prenant en considération le niveau du SOC. MÉTHODOLOGIE: Des participants édentés (n=172, âge moyen 71, SD = 4.5) ayant reçu des CDs ou des IODs ont été suivis sur une période de deux ans. L’OHRQoL a été évaluée à l’aide du questionnaire « Oral Health Impact Profile (OHIP -20) » et ce avant le traitement et à chacun des deux suivis. Le SOC a été évalué à l’aide du questionnaire « The Orientation to Life (SOC -13) » à chacun des deux suivis. Des analyses statistiques ont été effectuées pour évaluer les différences intra et entre groupes (analyses statistiques descriptives, bivariées et multivariées). RÉSULTATS: Une amélioration statistiquement significative de l’OHRQoL entre les statuts avant et après traitement a été notée dans les deux groupes (Wilks’s Lambda = 0.473, F (1,151) = 157.31, p < 0.0001). L’amplitude de l’effet du traitement IOD est 1.5 fois plus grande que celle du traitement CD. Ces résultats ont été stables pendant les deux années d’étude et ils n’ont pas été influencés par le SOC. CONCLUSION: Le traitement IOD amène une meilleure OHRQoL à long terme en comparaison avec le traitement CD et ce sans influence du niveau du SOC. Ces résultats sont cliniquement significatifs et confirment la supériorité des IODs sur les CDs. / ABSTRACT The superiority and stability of the effect of mandibular two-implant retained overdentures (IODs) over conventional dentures (CDs) in relation to the oral health-related quality of life (OHRQoL) remain to be clarified. Furthermore, the influence of psychological factors, such as the sense of coherence (SOC), on the perception of treatment outcomes is still unknown. The aim of this study was to determine the magnitude of the effect of IODs and CDs on the OHRQoL and assess the stability of the treatment over time taking into account the level of SOC. METHODOLOGY: Edentulous participants (n = 172, mean age 71, SD = 4.5) wearing CDs or IODs were followed up for two years. The OHRQoL was assessed at baseline and both follow-ups using the « Oral Health Impact Profile (OHIP-20) » questionnaire. The SOC was only assessed at both follow-ups using « The Orientation to Life (SOC-13) » questionnaire. Statistical analyses were conducted to evaluate between and within treatment differences (descriptive, bivariate and multivariate statistical analyses). RESULTS: A significant pre-/post-treatment improvement in the OHRQoL for both treatment groups was found (Wilks’s Lambda = 0.473, F (1,151) = 157.31, p < 0.0001). The magnitude of the effect in the IOD group was 1.5 times larger than that in the CD group. These outcomes were stable over the two-year study period and the SOC did not influence any of these results. CONCLUSION: IODs provide better long-term OHRQoL than CDs regardless of SOC level. The results are clinically meaningful and confirm the superiority of IODs over CDs.

Page generated in 0.0906 seconds