• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 89
  • Tagged with
  • 89
  • 89
  • 89
  • 45
  • 32
  • 23
  • 18
  • 16
  • 16
  • 15
  • 15
  • 14
  • 14
  • 13
  • 13
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Doença periodontal e prematuridade e ou baixo peso ao nascer / Periodontal disease and preterm and or low birth weight

Vettore, Mario Vianna January 2006 (has links)
Made available in DSpace on 2012-09-05T18:24:15Z (GMT). No. of bitstreams: 2 license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) 267.pdf: 3589701 bytes, checksum: e41a01f22ec53b3de950e983d91027c6 (MD5) Previous issue date: 2006 / Esta tese é apresentada sob a forma de artigos. Os quatro trabalhos apresentados neste estudo avaliaram a associação entre a doença periodontal (DP) e a prematuridade e/ou o baixo peso ao nascer (P/BPN). O primeiro artigo é uma revisão sistemática sobre DP e P/BPN. O segundo é o desenvolvimento e validação de um novo método epidemiológico para avaliação da DP, denominado Periodontal Inflammatory Load (PIL). O terceiro é um estudo caso-controle sobre a associação de medidas clínicas da DP com a P/BPN e o quarto, um estudo caso-controle aninhado que avaliou a relação da microbiota periodontal materna com a P/BPN. (...) Quatro grupos de casos foram analisados: prematuros, baixo peso ao nascer (BPN), prematuros e/ou com BPN, e prematuros e com BPN. Os resultados clínicos mostraram que os níveis de DP foram maiores nos grupos controles do que nos grupos de casos de P/BPN. A DP não aumentou o risco para a P/BPN utilizando 15 diferentes medidas clínicas de DP. Os casos de P/BPN apresentaram uma tendência de menores níveis de DP em relação aos controles quando a medida PIL foi empregada. A comparação da microbiota periodontal materna entre casos e controles em uma sub-amostra, não detectou diferenças em relação à média de proporções dos complexos microbianos. A média de contagens do patógeno periodontal Treponema socranskii foi menor nas puérperas com neonatos prematuros, e prematuros e com BPN, comparados aos controles. Concluiu-se que a doença periodontal não foi um fator de risco para a prematuridade, BPN, prematuridade e/ou BPN, e prematuridade e BPN em mulheres com 30 anos de idade ou mais.
32

O fumo na gestação em mulheres avaliadas em seis capitais brasileiras

Kroeff, Locimara Ramos January 2002 (has links)
Resumo não disponível.
33

Avaliação da medida da translucência nucal em gestantes com risco elevado de anomalia congênita

Sanseverino, Maria Teresa Vieira January 2005 (has links)
A medida da translucência nucal (TN) entre 11 e 14 semanas de gestação é um exame ultra-sonográfico que mede a camada líquida na região cervical posterior do feto, sendo observado um aumento de espessura nas anomalias cromossômicas, especialmente na trissomia 21. Com sua crescente utilização, outras anormalidades fetais têm sido descritas em associação a um aumento da TN. O objetivo deste trabalho foi avaliar o desempenho da medida da TN na detecção de diferentes anomalias fetais e outros efeitos adversos para a gestação. Realizou-se de um estudo observacional, no período de 1996 a 2004, com gestantes avaliadas no Ambulatório de Aconselhamento Genético para Diagnóstico Pré-natal do Hospital de Clínicas de Porto Alegre por risco aumentado de anomalia congênita, e que haviam realizado a medida da TN. Foram consideradas adequadas as TN realizadas de acordo com a padronização da Fundação de Medicina Fetal de Londres, e aumentadas aquelas TN com valor cima do percentil 95 para idade gestacional. Das 443 gestantes avaliadas, 38 seguimentos foram perdidos, 4 gestações estavam em curso na análise final dos dados, finalizando 401 gestações com desfecho conhecido. Em 275 gestações com TN adequada, a medida aumentada foi significativamente associada a anormalidades congênitas em geral (p 0,000000), cromossomopatias (p 0,000059) e perdas gestacionais (p 0,000000), sendo aumentada em oito dos 14 casos de cromossomopatia e em 6/7 dos casos com Síndrome de Down. Por outro lado, no grupo das TN inadequadas (126 casos), a associação entre TN aumentada não foi significativa para defeitos congênitos em geral (p 0,641396), nem para cromossomopatias (p 0,329194) ou perdas gestacionais (p 0,096092). Especificamente com relação aos erros inatos do metabolismo (EIM) no feto, foram localizados relatos e séries de casos com TN aumentada em dez diferentes EIM. Nas dezenove gestantes com história familiar de EIM e com medida da TN, houve um caso de uma menina afetada por MPS I com TN aumentada, e um de Raquitismo Resistente à Vitamina D com TN normal. Nos outros 17 casos, a medida da TN foi normal e não havia evidência de um EIM. Entre as novas associações de TN aumentada com síndromes genéticas, relatamos um paciente com Síndrome de Artrogripose, Anomalia renal e Colestase (ARC), cuja análise molecular na Universidade de Birmingham identificou uma mutação sem sentido (1518C>T) em homozigose no gene VPS33B. Concluiu-se que o desempenho da TN na detecção de anomalias congênitas depende da qualidade do exame, sendo que uma medida adequada aumentada está significativamente associada a defeitos congênitos, cromossomopatias e a outros desfechos gestacionais adversos, e que a sensibilidade da TN é especialmente elevada na detecção da síndrome de Down.
34

Rastreamento da insuficiência placentária através do Doppler das artérias uterinas por via transvaginal entre 22 e 24 semanas de gestação

Dias, Ricardo dos Santos Palma January 2005 (has links)
Resumo não disponível
35

Acurácia dos testes ultrassonográficos para predição de pré-eclâmpsia

Cunha Filho, Edson Vieira da January 2015 (has links)
Made available in DSpace on 2015-07-08T03:25:36Z (GMT). No. of bitstreams: 1 000471709-Texto+Completo-0.pdf: 569 bytes, checksum: a1f50431708ca0bea4c30e23836c423e (MD5) Previous issue date: 2015 / Objective : To develop a meta-analysis on ultrasonographic methods for preecalmpsia prediction. Methods : The databases MEDLINE, EMBASE, LILACS and SCIELO were searched for selecting studies and data extraction. We assessed study validity by QUADAS II. The statistical analysis was performed using summary operating point for qualitative variables and using summary ROC curves for quantitative variables. Results : In the gestation’s first trimester, ultrasound methods are not applicable for preeclampsia prediction due to low sensitivity. In the second trimester there are three feasible tests. For early preeclampsia prediction (birth < 34 weeks) the uterine arteries mean pulsatility index above 95th centile plus bilateral notching have a low negative likelihood ratio (0. 28) and high sensitivity (89%). For preeclampsia prediction at any time of gestation, resistance index may be used. Mean resistance index > 0. 58 is applicable for high risk pregnant women with an AUC of 0. 804. For pregnant women without risk for preeclampsia, the specificity of the bilateral resitance index > 0. 70 was 97%.Conclusion : In the first trimester ultrasound methods can not be used to predict preeclampsia. During the second trimester, the mean pulsatility index above 95th centile has the best predictive power. This test is applicable for low risk patients to predict preeclampsia below 34 weeks. The mean resistance index > 0. 58, with sensitivity and specificity around 74%, to predict preeclampsia at any time of gestation in high risk patients, can also be used. For low risk patients and preeclampsia prediction at any time of gestation, all tests had low sensitivities. / Objetivo : Realizar uma metanálise para testar a acurácia dos métodos ultrassonográficos para predição de pré-eclâmpsia.Métodos : Foi efteuada pesquisa nas bases de dados MEDLINE, EMBASE, LILACS e CIELO, onde os estudos foram selecionados. A validade dos estudos foi acessada pela ferramenta QUADAS II. A análise estatística foi feita utilizando summary operating point para variáveis qualitativas e summary ROC curve para variáveis quantitativas. Resultados : No primeiro trimestre da gestação, os métodos ultrassonográficos não têm aplicabilidade para predição de pré-eclâmpsia devido à sua baixa sensibilidade. No segundo trimestre, encontramos três testes que podem ser utilizados. Para predição de pré-eclâmpsia precoce (que culmina com nascimento abaixo das 34 semanas) o Índice de Pulsatilidade médio das artérias uterinas acima do percentil 95 associado à incisura protodiastólica bilateral teve uma baixa razão de verossimilhança negativa (0,28) e uma alta sensibilidade (89%). Para predição de pré-eclâmpsia a qualquer momento da gravidez, o índice de resistência pode ser usado. Índice de Resistência médio > 0,58 é aplicável para pacientes de alto risco, tendo uma área abaixo da curva de 0,804. Para grávidas de baixo risco de pré-eclâmpsia, a especificidade do Índice de Resistência bilateral > 0,70 foi de 97%.Conclusão : No primeiro trimestre não encontramos bons resultados com métodos ultrassonográficos para predição de pré-eclâmpsia. No segundo trimestre o índice de pulsatilidade médio acima do percentil 95 teve o melhor poder preditivo. Este teste é aplicável para pacientes de baixo risco e para predizer pré-eclâmpsia abaixo de 34 semanas. Podemos utilizar também o Índice de Resistência maior que 0,58, com sensibilidade e especificidade próximas as 74%, para predizer pré-eclâmpsia em pacientes de alto risco, com a doença ocorrendo em qualquer momento da gravidez. Para pacientes de baixo risco e predição de pré-eclâmpsia a qualquer momento da gestação os testes têm baixa sensibilidades.
36

Estratégias de controle da toxoplasmose congênita

Lago, Eleonor Gastal January 2006 (has links)
Made available in DSpace on 2013-08-07T19:07:20Z (GMT). No. of bitstreams: 1 000347388-Texto+Completo-0.pdf: 1857979 bytes, checksum: 98875a0d9c6f342bef2d9bc65c57b825 (MD5) Previous issue date: 2006 / Objectives – The first aim of this study was to determine the prevalence of congenital toxoplasmosis in infants treated by the public health system in Porto Alegre, a city of about 1,500,000 inhabitants in Southern Brazil, through neonatal screening for Toxoplasma gondii-specific IgM. The second aim was to investigate whether the cases of congenital toxoplasmosis detected by this approach would have been identified by the prenatal screening program for toxoplasmosis that had already been implemented for the same population. Methods – A fluorimetric assay was used to analyze Toxoplasma gondii-specific IgM in the same dried blood filter paper specimens obtained from all newborns for routine metabolic diseases screening. When the screening was positive, serum samples from the infant and the mother were requested for confirmatory Toxoplasma gondii serology, and the infant underwent complete clinical investigation. Results – Throughout 2002, 14,398 out of ~20,000 liveborn infants were screened for metabolic diseases in the public health system in Porto Alegre, and 10,000 cards from consecutive infants were examined for Toxoplasma gondii-specific IgM. Seven infants tested positive in filter paper, and congenital toxoplasmosis was confirmed in six of them. Three cases had already been identified at birth, because the mothers were tested at the time of delivery, and one case had already been identified in the maternity ward, before birth. Two cases have been identified solely by the neonatal screening. Conclusions – The prevalence of congenital toxoplasmosis was 6/10,000 (95% CI 2/10,000, 13/10,000). Neonatal screening identified cases of congenital toxoplasmosis undetected by prenatal screening, when maternal serology had not been done at delivery. If not complemented by additional testing at delivery or in the post-delivery period, prenatal screening may be inefficient in detecting toxoplasmosis acquired and transmitted in late pregnancy. Additionally, neonatal screening and maternal serology at delivery were useful in identifying congenital toxoplasmosis when the mother did not receive prenatal care. / Objetivos – O primeiro objetivo deste estudo foi avaliar a prevalência de toxoplasmose congênita em recém-nascidos atendidos na rede pública de saúde de Porto Alegre, cidade de cerca de 1. 500. 000 habitantes, localizada no sul do Brasil, através da triagem neonatal para IgM anti-T. gondii. O segundo objetivo foi verificar se os casos de toxoplasmose congênita identificados por esta metodologia teriam sido detectados pelo programa de triagem pré-natal já implantado na mesma população. Métodos – Foi utilizado um teste fluorimétrico para pesquisar a IgM anti- Toxoplasma gondii em amostras de sangue absorvidas em papel filtro, aproveitando as mesmas amostras rotineiramente obtidas de todos os recém-nascidos para triagem de doenças metabólicas. Quando a triagem era positiva para IgM anti-Toxoplasma gondii, eram solicitadas amostras séricas do lactente e da mãe para sorologia confirmatória, e o lactente era submetido a uma completa investigação clínica. Resultados – Durante o ano de 2002 o teste para IgM foi realizado em 10. 000 recém-nascidos consecutivos. Em sete pacientes o teste foi positivo, e em seis foi confirmada a toxoplasmose congênita. Três casos já haviam sido identificados ao nascimento, pois suas mães haviam sido testadas para toxoplasmose no momento do parto, e um caso havia sido identificado na maternidade, um pouco antes do nascimento. Dois casos de toxoplasmose congênita foram identificados somente pela triagem neonatal. Conclusões – A prevalência de toxoplasmose congênita foi de 6/10. 000 (IC 95%: 2/10. 000-13/10. 000). A triagem neonatal identificou casos de toxoplasmose congênita não detectados pela triagem pré-natal, quando a sorologia materna não havia sido feita no momento do parto. Se não complementada por um teste na hora do parto ou logo após o mesmo, a triagem pré-natal pode ser ineficiente em detectar a toxoplasmose adquirida e transmitida nas últimas semanas da gestação. Adicionalmente, a triagem neonatal e a sorologia materna no momento do parto identificaram casos de toxoplasmose congênita em que a mãe não havia realizado acompanhamento pré-natal.
37

Rastreamento da insuficiência placentária através do Doppler das artérias uterinas por via transvaginal entre 22 e 24 semanas de gestação

Dias, Ricardo dos Santos Palma January 2005 (has links)
Resumo não disponível
38

O fumo na gestação em mulheres avaliadas em seis capitais brasileiras

Kroeff, Locimara Ramos January 2002 (has links)
Resumo não disponível.
39

Avaliação da medida da translucência nucal em gestantes com risco elevado de anomalia congênita

Sanseverino, Maria Teresa Vieira January 2005 (has links)
A medida da translucência nucal (TN) entre 11 e 14 semanas de gestação é um exame ultra-sonográfico que mede a camada líquida na região cervical posterior do feto, sendo observado um aumento de espessura nas anomalias cromossômicas, especialmente na trissomia 21. Com sua crescente utilização, outras anormalidades fetais têm sido descritas em associação a um aumento da TN. O objetivo deste trabalho foi avaliar o desempenho da medida da TN na detecção de diferentes anomalias fetais e outros efeitos adversos para a gestação. Realizou-se de um estudo observacional, no período de 1996 a 2004, com gestantes avaliadas no Ambulatório de Aconselhamento Genético para Diagnóstico Pré-natal do Hospital de Clínicas de Porto Alegre por risco aumentado de anomalia congênita, e que haviam realizado a medida da TN. Foram consideradas adequadas as TN realizadas de acordo com a padronização da Fundação de Medicina Fetal de Londres, e aumentadas aquelas TN com valor cima do percentil 95 para idade gestacional. Das 443 gestantes avaliadas, 38 seguimentos foram perdidos, 4 gestações estavam em curso na análise final dos dados, finalizando 401 gestações com desfecho conhecido. Em 275 gestações com TN adequada, a medida aumentada foi significativamente associada a anormalidades congênitas em geral (p 0,000000), cromossomopatias (p 0,000059) e perdas gestacionais (p 0,000000), sendo aumentada em oito dos 14 casos de cromossomopatia e em 6/7 dos casos com Síndrome de Down. Por outro lado, no grupo das TN inadequadas (126 casos), a associação entre TN aumentada não foi significativa para defeitos congênitos em geral (p 0,641396), nem para cromossomopatias (p 0,329194) ou perdas gestacionais (p 0,096092). Especificamente com relação aos erros inatos do metabolismo (EIM) no feto, foram localizados relatos e séries de casos com TN aumentada em dez diferentes EIM. Nas dezenove gestantes com história familiar de EIM e com medida da TN, houve um caso de uma menina afetada por MPS I com TN aumentada, e um de Raquitismo Resistente à Vitamina D com TN normal. Nos outros 17 casos, a medida da TN foi normal e não havia evidência de um EIM. Entre as novas associações de TN aumentada com síndromes genéticas, relatamos um paciente com Síndrome de Artrogripose, Anomalia renal e Colestase (ARC), cuja análise molecular na Universidade de Birmingham identificou uma mutação sem sentido (1518C>T) em homozigose no gene VPS33B. Concluiu-se que o desempenho da TN na detecção de anomalias congênitas depende da qualidade do exame, sendo que uma medida adequada aumentada está significativamente associada a defeitos congênitos, cromossomopatias e a outros desfechos gestacionais adversos, e que a sensibilidade da TN é especialmente elevada na detecção da síndrome de Down.
40

Avaliação do desempenho do sistema de informações hospitalares (SIH-SUS) na identificação dos casos de near miss materno

Pereira, Marcos Nakamura January 2011 (has links)
Submitted by Carvalho Cristiane (crisedangelo@yahoo.com.br) on 2012-05-30T12:17:49Z No. of bitstreams: 1 Marcos Nakamura Pereira.pdf: 2337168 bytes, checksum: 8ed5a86601d971398b0db84852aa3df7 (MD5) / Made available in DSpace on 2012-05-30T12:17:49Z (GMT). No. of bitstreams: 1 Marcos Nakamura Pereira.pdf: 2337168 bytes, checksum: 8ed5a86601d971398b0db84852aa3df7 (MD5) / Fundação Oswaldo Cruz. Instituto Fernandes Figueira. Departamento de Ensino. Programa de Pós-Graduação em Saúde da Criança e da Mulher. Rio de Janeiro, RJ, Brasil / Este estudo tem por objetivo avaliar o desempenho do Sistema de Informações Hospitalares do Sistema Único de Saúde (SIH-SUS) na identificação dos casos de near miss materno ocorridos, em um hospital terciário da cidade do Rio de Janeiro, no ano de 2008. A identificação dos casos se deu pela avaliação dos prontuários médicos das mulheres que apresentaram condições potencialmente ameaçadoras à vida, selecionados a partir da revisão dos sumários de alta hospitalar, sendo este processo considerado o padrão-ouro. A segunda etapa do estudo consistiu no escrutínio das informações contidas no SIH-SUS, através da busca nominal dos casos de near miss materno identificados pela revisão dos prontuários e da seleção das AIHs cujos campos “Diagnóstico Principal”, “Diagnóstico Secundário” e/ou “Procedimento Realizado” apresentassem codificações compatíveis com este agravo, realizando-se então a avaliação das propriedades diagnósticas do SIH-SUS. Após avaliação de 1.170 sumários de internação hospitalar, foram selecionados 228 casos para a revisão dos prontuários. Após revisão das informações contidas nos registros médicos, foram identificados 165 casos de morbidade materna grave, dentre as quais 8 evoluíram com óbito materno, 130 cursaram com situações de morbidade grave não caracterizadas como near miss materno e 27 efetivamente apresentaram-se como casos de near miss materno. Na avaliação inicial do desempenho do SIH-SUS, através da busca nominal das mulheres identificadas com near miss, constatou-se que apenas 16 (59,2%) casos estavam no banco de dados. Acerca da ausência dos outros 11 casos (40.7%) restantes no sistema, foi possível detectar que ao menos 4 (36,3%) deles decorreram pelo não faturamento AIH por haver excedido o limite percentual de cesarianas do hospital. Analisando as propriedades diagnósticas do SIH-SUS, obteve-se sensibilidade de 18,5% (IC95% = 6,3-38,1), valor preditivo positivo de 7,14% (IC95% = 2,36-13,9), especificidade de 94,3 (IC95% = 92,8-95,6) e área sob a curva ROC de 0,56 (IC95% = 0,48-0,63). Considerando os resultados obtidos, em princípio, o SIH-SUS não parece ser boa ferramenta para vigilância do near miss materno. / The aim of this study is to evaluate the performance of the Hospital Information System (SIH) of Brazilian National Health Service in identifying cases of maternal near miss in a tertiary hospital in the city of Rio de Janeiro, during the year of 2008. The identification of such cases was done through evaluation of the medical records of patients who presented with potential life-threatening conditions. The cases were selected after revision of the discharge summaries of those patients; this process is considered gold-standard. The second phase of the study consisted in the scrutiny of the information in the SIH-SUS, through a nominal search of the maternal near miss cases identified from the revision of medical records and selection of the Hospital Admittance Forms (AIH) which the fields “primary diagnosis”, “secondary diagnosis” and/or “performed procedure” presented data compatible with such grievance, thus evaluating the diagnostic properties of the SIH. After evaluation of 1.170 hospital chart summaries, 228 cases were selected for a full chart revision. After revision of the information in the medical charts 165 cases of severe maternal morbidity were identified, among which 8 resulted in maternal death, 130 were cases of severe maternal morbidity not classified as near miss, and 27 were effectively considered maternal near miss cases. In the initial evaluation of the SIH performance through the nominal search of women identified as near miss, it was detected that only 16 (59. 2%) cases were in the database. Regarding the absence of the other 11 (40.7%) remaining cases, it was detected that at least 4 (36.3%) of them resulted from the non-billing of the procedures because the hospital’s cesarean-section percentage limit had been exceeded. An analysis of the diagnostic properties of the SIH showed a 18,5% sensibility (95%CI = 6.3 – 38.1), 7.14% positive predictive value (95%IC = 2.36-15.9), 94.3% specificity (95%CI = 92.8 – 95.6) and area under the ROC curve of 0.56 (95%CI = 0.48 – 0.63). At a first look, considering the results obtained,the SIH does not seem to be a good tool for surveillance of maternal near miss.

Page generated in 0.0818 seconds