Développement d'une camera x couleur ultra-rapide a pixels hybrides / Development of an ultra-fast X-ray camera using hybrid pixel detectors

Dawiec, Arkadiusz 04 May 2011 (has links)
L’objectif du projet, dont le travail présenté dans cette thèse est une partie, était de développer une caméra à rayons X ultra-rapide utilisant des pixels hybrides pour l’imagerie biomédicale et la science des matériaux. La technologie à pixels hybrides permet de répondre aux besoins des ces deux champs de recherche, en particulier en apportant la possibilité de sélectionner l’énergie des rayons X détectés et de les imager à faible dose. Dans cette thèse, nous présentons une caméra ultra-rapide basée sur l’utilisation de circuits intégrés XPAD3-S développés pour le comptage de rayons X. En collaboration avec l’ESRF et SOLEIL, le CPPM a construit trois caméras XPAD3. Deux d’entre elles sont utilisée sur les lignes de faisceau des synchrotrons SOLEIL et ESRF, et le troisième est installé dans le dispositif d’irradiation PIXSCAN II du CPPM. La caméra XPAD3 est un détecteur de rayons X de grande surface composé de huit modules de détection comprenant chacun sept circuits XPAD3-S équipés d’un système d’acquisition de données ultra-rapide. Le système de lecture de la caméra est basé sur l’interface PCI Express et sur l’utilisation de circuits programmables FPGA. La caméra permet d’obtenir jusqu’à 240 images/s, le nombre maximum d’images étant limité par la taille de la mémoire RAM du PC d’acquisition. Les performances de ce dispositif ont été caractérisées grâce à plusieurs expériences à haut débit de lecture réalisées dans le système d’irradiation PIXSCAN II. Celles-ci sont décrites dans le dernier chapitre de cette thèse. / The aim of the project, of which the work described in this thesis is part, was to design a high-speed X-ray camera using hybrid pixels applied to biomedical imaging and for material science. As a matter of fact the hybrid pixel technology meets the requirements of these two research fields, particularly by providing energy selection and low dose imaging capabilities. In this thesis, high frame rate X-ray imaging based on the XPAD3-S photons counting chip is presented. Within a collaboration between CPPM, ESRF and SOLEIL, three XPAD3 cameras were built. Two of them are being operated at the beamline of the ESRF and SOLEIL synchrotron facilities and the third one is embedded in the PIXSCAN II irradiation setup of CPPM. The XPAD3 camera is a large surface X-ray detector composed of eight detection modules of seven XPAD3-S chips each with a high-speed data acquisition system. The readout architecture of the camera is based on the PCI Express interface and on programmable FPGA chips. The camera achieves a readout speed of 240 images/s, with maximum number of images limited by the RAM memory of the acquisition PC. The performance of the device was characterize by carrying out several high speed imaging experiments using the PIXSCAN II irradiation setup described in the last chapter of this thesis.
22

Apport des structures ridge pour la détection et l’interférométrie à conversion de fréquence MIR en régime de comptage de photons / Contribution of ridge waveguides for MIR upconversion detection and interferometry in photon counting regime

Lehmann, Lucien 21 November 2019 (has links)
La détection faible flux dans le moyen infrarouge (MIR) est fortement pénalisée par le rayonnement thermique de l’environnement. La principale solution à ce problème consiste à cryogéniser la plus grande partie possible de la chaîne de détection. Cette méthode atteint ses limites pour certaines applications,notamment l’imagerie haute résolution en astronomie par méthode interférométrique. Une solution alternative consiste à utiliser le processus non linéaire de somme de fréquences pour convertir ce rayonnement moyen infrarouge vers des domaines de longueur d’onde où les détecteurs ne sont plus limités par le rayonnement de l’environnement et fonctionnent efficacement en régime de comptage de photons. Les travaux effectués au cours ces trois années sont le prolongement direct de plus d’une décennie de recherche pour la détection et l’interférométrie par conversion de fréquence. Ils s’inscrivent dans la continuité des travaux de thèses de L. Szemendera et de P. Darré, ayant, pour l’un, posé les premières pierres de l’interférométrie par conversion de fréquence dans le MIR et, pour l’autre, démontré la possibilité d’utiliser cette technique sur le ciel à1550 nmen tirant parti de la technologie de guidage ridge. Cette thèse constitue donc la jonction fructueuse de ces travaux antérieurs, rendue possible par une collaboration avec l’institut Femto-ST. L’utilisation de leurs guides PPLN ridge nous a permis de nous placer au niveau de l’état de l’art pour la détection par conversion de fréquence dans le MIR (3,5 μm)avec des démonstrations expérimentales à la fois en laboratoire et sur le ciel (C2PU). Intégrée à un interféromètre à conversion de fréquence à ces mêmes longueurs d’onde, elle a également permis d’en améliorer significativement les performances et la répétabilité de cette technique, principalement dans le cas d’une source spectralement large bande. Parallèlement, notre collaboration avec le réseau de télescopes CHARA, nous a offert l’opportunité d’étudier les problématiques soulevées par une future mise en œuvre de l’instrument sur ce site. / Low flux detection in the mid infrared (MIR) is strongly penalized by thermal radiation from the environment. The main solution to this problem is to cryogenize as much of the detection chain as possible.This method is reaching its limits for some applications, including high-resolution imaging in astronomy using interferometric methods. An alternative solution is to use the non-linear process of sum frequency generation to convert this mid infrared radiation to wave length domains where detectors are no longer limited by the radiation from environment and operate efficiently in photon counting regime.The work over these three years is part of more than a decade of research into up-conversion detection and interferometry. It is the expansion of the these works of L. Szemendera and P. Darré. The first one laid the fondation of the up-conversion interferometry in the MIR and the second one demonstrated the possibility of using this technique on the sky at 1550 nm by benefiting from the ridge waveguide technology.Thus, this thesis constitutes the fruitful junction of these earlier works, made possible by a collaboration with the Femto-ST Institute. The use of their PPLN ridge waveguides has enabled us to place ourselves at the state of the art for up-conversion detection in the MIR (3,5 μm) with experimental demonstrations both in the laboratory and on the sky (C2PU). Integrated into a up-conversion interferometer at these same wave lengths, it has also significantly improved the performance and repeatability of this technique,in particular in the case of a spectrally broadband source. At the same time, our collaboration with the CHARA telescope array gave us the opportunity to study the problems raised by a future implementation of the instrument on this site.
23

L'interféromètre à somme de fréquences ALOHA en bande H : Des tests en laboratoire jusqu'aux premières franges sur le ciel / The upconversion interferometer ALOHA operating in H band : From the laboratory to the first on-sky

Darré, Pascaline 29 September 2016 (has links)
La technique de l'interférométrie en astronomie permet d'observer des objets avec une haute résolution angulaire comparativement à l'utilisation d'un unique télescope. L'observation dans l'infrarouge moyen représente aujourd'hui un enjeu en interférométrie notamment pour l'étude des noyaux actifs de galaxie ou de la formation des planètes. Cependant ce domaine spectral est particulièrement contraignant puisqu'il est soumis à l'émission propre des éléments optiques de l'instrument mais également de l'atmosphère. Ce manuscrit développe les travaux effectués sur un nouvel instrument utilisant un processus de conversion de fréquence pour transposer le rayonnement infrarouge vers un domaine spectral permettant de s'affranchir de l'émission propres des optiques. Un prototype fonctionnant dans le proche infrarouge à 1,55 µm et convertissant, via une processus de somme de fréquences, le rayonnement dans le domaine visible autour de 630 nm grâce à une pompe intense à 1064 nm, a été mis en place pour démontrer, en laboratoire, le principe de cette solution innovante notamment dans le cadre de l'analyse de la cohérence spatiale d'un corps noir. L'objectif est maintenant de démontrer la capacité de l'instrument à détecter un objet réel. J'introduis dans cette thèse les notions théoriques essentielles à la compréhension des travaux présentés pour ensuite détailler le fonctionnement de l'instrument et les éléments d'amélioration apportés, notamment en terme de transmission, au cours de ma thèse. Les études préliminaires en laboratoire du comportement de l'instrument ont permis d'aboutir aux premières franges sur le ciel en utilisant la plus petite base (34 m) du réseau interférométrique CHARA et de rechercher la magnitude limite de l'instrument. L'utilisation du processus de conversion de fréquence a pour conséquence de filtrer le spectre converti. Ainsi dans la configuration actuelle de l'interféromètre, seul 0,6 nm du spectre infrarouge en entrée du cristal est converti à travers le processus de SFG. Afin d'augmenter la sensibilité, une solution est de créer plusieurs processus de SFG simultanément dans chaque étage de conversion afin d'échantillonner le spectre infrarouge converti. Cette solution requiert d'utiliser plusieurs sources de pompe indépendantes qui vont créer des systèmes de franges incohérents. Je présente l'analyse de la cohérence temporelle d'une source infrarouge large bande convertie via l'utilisation de deux sources de pompe et un moyen de synchroniser les différents systèmes de franges afin de maximiser le contraste. / Interferometry is an instrumental technique suitable to perform astronomical observations at high angular resolution. Currently, the mid-infrared spectral domain is a real issue for the astronomical interferometry to characterize astronomical objects such as proto-planetary discs or active galactic nuclei. However, this spectral domain is subject to a large thermal background emission from the instrument and from the sky. This manuscript describes an innovative instrument using a nonlinear process of sum frequency generation to convert the mid-infrared radiation to a shorter wavelength domain where the thermal emission from the instrument is negligible. A prototype operating in the near-infrared at 1.55 µm and converting the radiation in the visible domain at 630 nm thanks to a strong pump at 1064 nm has already demonstrated its ability to analyse spatial coherence of a blackbody source. The present goal is to demonstrate its ability to detect an object on the sky. In this manuscript I introduce theoritical concepts necessary for an understanding of the overall operation of the instrument. Then, I describe the main improvements provided in this thesis, in particular concerning the instrumental transmission. The preliminary studies of the instrument operation resulted in the first on-sky fringes on the CHARA array and enabled to determine its limiting magnitude. The upconversion process acts as a filter on the converted spectrum. In the current instrumental configuration, only 0.6 nm of the input infrared spectrum is converted through the SFG process. For the purpose of increasing the instrumental sensitivity, we propose to sample the infrared spectrum by using several independent pump laser lines thus creating different incoherent fringe patterns. I present the temporal coherence analysis of a broadband infrared source converted by a dual-line pump laser and a method to synchronize the different fringe patterns to insure a maximum value of the contrast.
24

Quantitative material decomposition methods for X-ray spectral CT / Méthodes de décomposition quantitative des matériaux pour la tomographie spectrale aux rayons X

Su, Ting 28 June 2018 (has links)
La tomographie (CT) aux rayons X joue un rôle important dans l'imagerie non invasive depuis son introduction. Au cours des dernières années, de nombreuses avancées technologiques en tomographie par rayons X ont été observées, notamment la CT spectrale, qui utilise un détecteur à comptage de photons (PCD) pour discriminer les photons transmis correspondant à des bandes d'énergie sélectionnées afin d'obtenir une information spectrale. La CT spectrale permet de surmonter de nombreuses limitations des techniques précédentes et ouvre de nombreuses applications nouvelles, parmi lesquelles la décomposition quantitative des matériaux est le sujet le plus étudié. Un certain nombre de méthodes de décomposition des matériaux ont été rapportées et différents systèmes expérimentaux sont en cours de développement pour la CT spectrale. Selon le type de données sur lequel l'étape de décomposition fonctionne, nous avons les méthodes du domaine des projections (décomposition avant reconstruction) et les méthodes du domaine de l'image reconstruite (décomposition après reconstruction). La décomposition couramment utilisée est basée sur le critère des moindres carrés, nommée proj-LS et méthode ima-LS. Cependant, le problème inverse de la décomposition du matériau est généralement mal posé et les mesures du CT spectral aux rayons X souffrent de bruits de comptage de photons de Poisson. Le critère des moindres carrés peut conduire à un surajustement des données de mesure bruitées. Dans le présent travail, nous avons proposé un critère de moindre log-carré pour la méthode du domaine de projection afin de minimiser les erreurs sur le coefficient d'atténuation linéaire: méthode proj-LLS. De plus, pour réduire l'effet du bruit et lisser les images, nous avons proposé d'ajouter un terme de régularisation par patch pour pénaliser la somme des variations au carré dans chaque zone pour les décompositions des deux domaines, nommées proj-PR-LLS et ima -PR-LS méthode. Les performances des différentes méthodes ont été évaluées par des études de simulation avec des fantômes spécifiques pour différentes applications: (1) Application médicale: identification de l'iode et du calcium. Les résultats de la décomposition des méthodes proposées montrent que le calcium et l'iode peuvent être bien séparés et quantifiés par rapport aux tissus mous. (2) Application industrielle: tri des plastiques avec ou sans retardateur de flamme. Les résultats montrent que 3 types de matériaux ABS avec différents retardateurs de flamme peuvent être séparés lorsque l'épaisseur de l'échantillon est favorable. Enfin, nous avons simulé l'imagerie par CT spectrale avec un fantôme de PMMA rempli de solutions de Fe, Ca et K. Différents paramètres d'acquisition, c'est-à-dire le facteur d'exposition et le nombre de bandes d'énergie, ont été simulés pour étudier leur influence sur la performance de décomposition pour la détermination du fer. / X-ray computed tomography (X-ray CT) plays an important part in non-invasive imaging since its introduction. During the past few years, numerous technological advances in X-ray CT have been observed, including spectral CT, which uses photon counting detectors (PCDs) to discriminate transmitted photons corresponding to selected energy bins in order to obtain spectral information with one single acquisition. Spectral CT enables us to overcome many limitations of the conventional CT techniques and opens up many new application possibilities, among which quantitative material decomposition is the hottest topic. A number of material decomposition methods have been reported and different experimental systems are under development for spectral CT. According to the type of data on which the decomposition step operates, we have projection domain method (decomposition before reconstruction) and image domain method (decomposition after reconstruction). The commonly used decomposition is based on least square criterion, named proj-LS and ima-LS method. However, the inverse problem of material decomposition is usually ill-posed and the X-ray spectral CT measurements suffer from Poisson photon counting noise. The standard LS criterion can lead to overfitting to the noisy measurement data. In the present work, we have proposed a least log-squares criterion for projection domain method to minimize the errors on linear attenuation coefficient: proj-LLS method. Furthermore, to reduce the effect of noise and enforce smoothness, we have proposed to add a patchwise regularization term to penalize the sum of the square variations within each patch for both projection domain and image domain decomposition, named proj-PR-LLS and ima-PR-LS method. The performances of the different methods were evaluated by spectral CT simulation studies with specific phantoms for different applications: (1) Medical application: iodine and calcium identification. The decomposition results of the proposed methods show that calcium and iodine can be well separated and quantified from soft tissues. (2) Industrial application: ABS-flame retardants (FR) plastic sorting. Results show that 3 kinds of ABS materials with different flame retardants can be separated when the sample thickness is favorable. Meanwhile, we simulated spectral CT imaging with a PMMA phantom filled with Fe, Ca and K solutions. Different acquisition parameters, i.e. exposure factor and number of energy bins were simulated to investigate their influence on the performance of the proposed methods for iron determination.
25

Imagerie rapide en comptage de photons, application à l'interférométrie stellaire optique à longue base

Morel, Sébastien 27 November 1998 (has links) (PDF)
L'acquisition d'images en comptage de photons du spectre visible, avec une grande précision sur la date de chaque photo événement, est particulièrement profitable pour les techniques d'observation au sol. Dans la première partie de cette thèse, après une revue des différentes techniques d'acquisition et de traitements des photoévénements, je présente un nouveau type de caméra à comptage, remarquable pour sa haute résolution temporelle et son haut flux maximum, la caméra DELTA (Détection d'Événements Lumineux par Trois Axes). Je décris le principe de cette caméra, ainsi que différentes solutions techniques (optique, électronique, informatique) qui pourraient être employées. J'expose également des nouvelles techniques de mesure et d'exploitation de l'information temporelle liée aux photoévénements. La seconde partie de mon travail concerne la détection et le suivi des franges en interférométrie stellaire optique à longue base au sol. Après une étude statistique du problème, je décris les différentes façons d'introduire dans les données de l'information a priori pour une meilleure efficacité de la détection. Une des méthodes proposées, utilisant l'information a priori sur le piston atmosphérique fait appel a une datation précise des photons, et par conséquent aux techniques décrites dans la première partie.
26

Influence de la topologie magnétique, de la cathode et de la section du canal sur l'accélération des ions dans un propulseur à effet Hall / Influence of magnetic topology, cathode and channel width on ion acceleration processes in a Hall effect thruster

Bourgeois, Guillaume 27 September 2012 (has links)
Les propulseurs électriques sont de plus en plus utilisés pour des missions de correction de trajectoire des satellites et pourront dans un avenir proche être utilisés pour le transfert d’orbite. Ces propulseurs constituent une excellente alternative aux propulseurs chimiques grâce à leur rendement élevé et une substantielle économie de carburant réalisée par rapport aux propulseurs chimiques. Les propulseurs à effet Hall créent la poussée par l’accélération d’ions positifs de xénon ou de krypton dans un plasma confiné par un champ magnétique. L’objet de ce manuscrit concerne principalement les caractéristiques de l’accélération des ions et des atomes dans un propulseur à effet Hall. Les influences de la largeur du canal de décharge, de la topologie magnétique et de la cathode sur l’efficacité d’accélération des ions sont étudiées. Des pistes d’optimisation de l’architecture du propulseur sont alors proposées qui pourraient être particulièrement avantageuses sur les propulseurs de petite taille, comme l’élargissement du canal et l’augmentation du champ magnétique près des parois du canal. L’influence de la position et du potentiel de la cathode sur la déviation du faisceau ionique est révélée. L’évolution temporelle basse fréquence du champ électrique est mesurée par comptage synchrone de photons et suggère que la température atomique joue un rôle important dans les oscillations basse fréquence de la décharge. Par ailleurs, l’influence du champ magnétique sur les performances d’un propulseur proche des modèles de vol a été mesurée grâce à l’utilisation d’un moteur doté d’une topologie magnétique flexible. Ceci a montré la difficulté de définir un paramètre numérique capable de synthétiser l’information complexe de la répartition spatiale du champ magnétique dans le canal de décharge. Les très faibles modifications des performances par le champ magnétique soulignent l’importance de la précision dans la mesure. / Electric propulsion systems are more and more often used for trajectory correction of satellites and may soon be used for orbit transfer. These devices represent a great alternative to classic chemical propulsion devices thanks to their high efficiency and propellant mass savings. Hall effect thruster provide thrust by the acceleration of xenon or krypton ions in a magnetized confined plasma. The study presented in this manuscript mainly addresses characteristics of ion and atom acceleration in a Hall effect thruster. Influence of channel width, magnetic topology and cathode parameters on ion acceleration efficiency is investigated. Ways to optimize thruster architecture are suggested that may be particularly relevant for low power thrusters, such as widening thruster channel and increasing magnetic field amplitude near channel walls. Influence of cathode position with respect to the thruster channel exit plane and its potential with respect to ground on ion beam deviation has been revealed with two thrusters. Low frequency time evolution of the accelerating electric field was measured using lock-in photon counting system. Results strongly suggest that the atom temperature plays a crucial role in low frequency time evolution of the whole plasma discharge. Measurement of performances as a function of the magnetic field demonstrated that numeric parameters are compulsory to carry on a relevant parametric study. These parameters would summarize the 2D information of magnetic topology. Weak influence of magnetic topology revealed that thrust measurement precision needs to be increased by at least one order of magnitude if one wants to reach a better understanding of plasma confinement in a Hall effect thruster.
27

Spectro-imagerie optique à faible flux et comparaison de la cinématique Ha et HI d'un échantillon de galaxies proches

Daigle, Olivier 02 1900 (has links)
Un nouveau contrôleur de EMCCD (Electron multiplying Charge Coupled Device) est présenté. Il permet de diminuer significativement le bruit qui domine lorsque la puce EMCCD est utilisé pour du comptage de photons: le bruit d'injection de charge. À l'aide de ce contrôleur, une caméra EMCCD scientifique a été construite, caractérisée en laboratoire et testée à l'observatoire du mont Mégantic. Cette nouvelle caméra permet, entre autres, de réaliser des observations de la cinématique des galaxies par spectroscopie de champ intégral par interférométrie de Fabry-Perot en lumière Ha beaucoup plus rapidement, ou de galaxies de plus faible luminosité, que les caméras à comptage de photon basées sur des tubes amplificateurs. Le temps d'intégration nécessaire à l'obtention d'un rapport signal sur bruit donné est environ 4 fois moindre qu'avec les anciennes caméras. Les applications d'un tel appareil d'imagerie sont nombreuses: photométrie rapide et faible flux, spectroscopie à haute résolution spectrale et temporelle, imagerie limitée par la diffraction à partir de télescopes terrestres (lucky imaging), etc. D'un point de vue technique, la caméra est dominée par le bruit de Poisson pour les flux lumineux supérieurs à 0.002 photon/pixel/image. D'un autre côté, la raie d'hydrogène neutre (HI) à 21 cm a souvent été utilisée pour étudier la cinématique des galaxies. L'hydrogène neutre a l'avantage de se retrouver en quantité détectable au-delà du disque optique des galaxies. Cependant, la résolution spatiale de ces observations est moindre que leurs équivalents réalisés en lumière visible. Lors de la comparaison des données HI, avec des données à plus haute résolution, certaines différences étaient simplement attribuées à la faible résolution des observations HI. Le projet THINGS (The HI Nearby Galaxy Survey a observé plusieurs galaxies de l'échantillon SINGS (Spitzer Infrared Nearby Galaxies Survey). Les données cinématiques du projet THIGNS seront comparées aux données cinématiques obtenues en lumière Ha, afin de déterminer si la seule différence de résolution spatiale peut expliquer les différences observées. Les résultats montrent que des différences intrinsèques aux traceurs utilisées (hydrogène neutre ou ionisé), sont responsables de dissemblances importantes. La compréhension de ces particularités est importante: la distribution de la matière sombre, dérivée de la rotation des galaxies, est un test de certains modèles cosmologiques. / A new EMCCD (Electron multiplying Charge Coupled Device) controller is presented. It allows the EMCCD to be used for photon counting by drastically taking down its dominating source of noise : the clock induced charges. A new EMCCD camera was built using this controller. It has been characterized in laboratory and tested at the observatoire du mont Mégantic. When compared to the previous generation of photon counting cameras based on intensifier tubes, this new camera renders the observation of the galaxies kinematics with an integral field spectrometer with a Fabry-Perot interferometer in Ha light much faster, and allows fainter galaxies to be observed. The integration time required to reach a given signal-to-noise ratio is about 4 times less than with the intensifier tubes. Many applications could benefit of such a camera: fast, faint flux photometry, high spectral and temporal resolution spectroscopy, earth-based diffraction limited imagery (lucky imaging), etc. Technically, the camera is dominated by the shot noise for flux higher than 0.002 photon/pixel/image. The 21 cm emission line of the neutral hydrogen (HI) is often used to map the galaxies kinematics. The extent of the distribution of the neutral hydrogen in galaxies, which goes well beyond the optical disk, is one of the reasons this line is used so often. However, the spatial resolution of such observations is limited when compared to their optical equivalents. When comparing the HI data to higher resolution ones, some differences were simply attributed to the beam smearing of the HI caused by its lower resolution. The THINGS (The HI Nearby Galaxy Survey) project observed many galaxies of the SINGS (Spitzer Infrared Nearby Galaxies Survey) project. The kinematics of THINGS will be compared to the kinematic data of the galaxies obtained in Ha light. The comparison will try to determine whether the sole beam smearing is responsible of the differences observed. The results shows that intrinsic dissimilarities between the kinematical tracers used are responsible of some of the observed disagreements. The understanding of theses differences is of a high importance as the dark matter distribution, inferred from the rotation of the galaxies, is a test to some cosmological models.
28

Spectro-imagerie optique à faible flux et comparaison de la cinématique Ha et HI d'un échantillon de galaxies proches

Daigle, Olivier 02 1900 (has links)
Un nouveau contrôleur de EMCCD (Electron multiplying Charge Coupled Device) est présenté. Il permet de diminuer significativement le bruit qui domine lorsque la puce EMCCD est utilisé pour du comptage de photons: le bruit d'injection de charge. À l'aide de ce contrôleur, une caméra EMCCD scientifique a été construite, caractérisée en laboratoire et testée à l'observatoire du mont Mégantic. Cette nouvelle caméra permet, entre autres, de réaliser des observations de la cinématique des galaxies par spectroscopie de champ intégral par interférométrie de Fabry-Perot en lumière Ha beaucoup plus rapidement, ou de galaxies de plus faible luminosité, que les caméras à comptage de photon basées sur des tubes amplificateurs. Le temps d'intégration nécessaire à l'obtention d'un rapport signal sur bruit donné est environ 4 fois moindre qu'avec les anciennes caméras. Les applications d'un tel appareil d'imagerie sont nombreuses: photométrie rapide et faible flux, spectroscopie à haute résolution spectrale et temporelle, imagerie limitée par la diffraction à partir de télescopes terrestres (lucky imaging), etc. D'un point de vue technique, la caméra est dominée par le bruit de Poisson pour les flux lumineux supérieurs à 0.002 photon/pixel/image. D'un autre côté, la raie d'hydrogène neutre (HI) à 21 cm a souvent été utilisée pour étudier la cinématique des galaxies. L'hydrogène neutre a l'avantage de se retrouver en quantité détectable au-delà du disque optique des galaxies. Cependant, la résolution spatiale de ces observations est moindre que leurs équivalents réalisés en lumière visible. Lors de la comparaison des données HI, avec des données à plus haute résolution, certaines différences étaient simplement attribuées à la faible résolution des observations HI. Le projet THINGS (The HI Nearby Galaxy Survey a observé plusieurs galaxies de l'échantillon SINGS (Spitzer Infrared Nearby Galaxies Survey). Les données cinématiques du projet THIGNS seront comparées aux données cinématiques obtenues en lumière Ha, afin de déterminer si la seule différence de résolution spatiale peut expliquer les différences observées. Les résultats montrent que des différences intrinsèques aux traceurs utilisées (hydrogène neutre ou ionisé), sont responsables de dissemblances importantes. La compréhension de ces particularités est importante: la distribution de la matière sombre, dérivée de la rotation des galaxies, est un test de certains modèles cosmologiques. / A new EMCCD (Electron multiplying Charge Coupled Device) controller is presented. It allows the EMCCD to be used for photon counting by drastically taking down its dominating source of noise : the clock induced charges. A new EMCCD camera was built using this controller. It has been characterized in laboratory and tested at the observatoire du mont Mégantic. When compared to the previous generation of photon counting cameras based on intensifier tubes, this new camera renders the observation of the galaxies kinematics with an integral field spectrometer with a Fabry-Perot interferometer in Ha light much faster, and allows fainter galaxies to be observed. The integration time required to reach a given signal-to-noise ratio is about 4 times less than with the intensifier tubes. Many applications could benefit of such a camera: fast, faint flux photometry, high spectral and temporal resolution spectroscopy, earth-based diffraction limited imagery (lucky imaging), etc. Technically, the camera is dominated by the shot noise for flux higher than 0.002 photon/pixel/image. The 21 cm emission line of the neutral hydrogen (HI) is often used to map the galaxies kinematics. The extent of the distribution of the neutral hydrogen in galaxies, which goes well beyond the optical disk, is one of the reasons this line is used so often. However, the spatial resolution of such observations is limited when compared to their optical equivalents. When comparing the HI data to higher resolution ones, some differences were simply attributed to the beam smearing of the HI caused by its lower resolution. The THINGS (The HI Nearby Galaxy Survey) project observed many galaxies of the SINGS (Spitzer Infrared Nearby Galaxies Survey) project. The kinematics of THINGS will be compared to the kinematic data of the galaxies obtained in Ha light. The comparison will try to determine whether the sole beam smearing is responsible of the differences observed. The results shows that intrinsic dissimilarities between the kinematical tracers used are responsible of some of the observed disagreements. The understanding of theses differences is of a high importance as the dark matter distribution, inferred from the rotation of the galaxies, is a test to some cosmological models.
29

Développement de Jonctions Supraconductrices à Effet Tunnel pour le comptage de photons en astronomie

Jorel, Corentin 20 December 2004 (has links) (PDF)
Cette thèse présente la poursuite des travaux grenoblois de développement des Jonctions Supraconductrices à Effet Tunnel (JSET) de types S/Al-AlO_x-Al/S pour le comptage de photons individuels en vue d'applications astronomiques dans l'infrarouge proche. La couche supraconductrice S, en niobium ou en tantale dans notre cas, est photo-absorbante et permet la conversion de l'énergie d'un photon incident en une population de charges excitées dont le nombre est proportionnel à l'énergie déposée et la durée de vie suffisante pour qu'elles soient comptées par effet tunnel. Il suffit pour cela de polariser en tension des jonctions à très basse température (100mK) et d'intégrer les impulsions de courant tunnel photo-induit pour évaluer l'énergie absorbée. L'intérêt des JSET pour la détection lumineuse est discuté dans le premier chapitre au travers de la comparaison des techniques performantes actuelles, aussi bien à base de supraconducteurs (Bolomètres à transition supraconductrice, Bolomètres à électrons chauds) que classiques (Photo-Diodes à Avalanche, Photo-Multiplicateurs, CCD et CMOS). Au démarrage de cette thèse, un procédé de fabrication avait permis d'obtenir des jonctions à base de niobium de bonne qualité et des résultats préliminaires en comptage de photons. L'objectif double était de passer à des jonctions à base de tantale, intrinsèquement plus sensibles, avec un nouveau procédé de fabrication collective plus performant. Dans un premier temps nous avons optimisé la qualité cristalline du dépôt de tantale. Les analyses structurales par rayons X montrent que ces films, déposés par pulvérisation cathodique magnétron à 600$^o$C sur substrat saphir plan-R recouvert d'une sous couche de Nb sont épitaxiés suivant l'axe (100). Les mesures de transport électrique à basse température donnent d'excellents rapports résistifs relatifs (de l'ordre de 45) conduisant à des libres parcours moyens de l'ordre de 100 nm. Dans un second temps, un nouveau procédé original de fabrication collective des jonctions a été imaginé et un jeu de 5 masques a été réalisé. Ces masques permettent la réalisation de jonctions individuelles de différentes tailles (de 25 par 25 à 50 par 50 microns carrés) et formes (quelques dispositifs ont une géométrie en losange ou en forme sinusoïdale). Ils autorisent aussi la réalisation de jonctions multiples sur un absorbeur commun ou de réseau de 9 jonctions (pixels). Le développement de ce procédé et sa fiabilisation ont permis d'obtenir un très fort pourcentage ( >90$%) de jonctions de qualité. Nous avons ainsi obtenu d'excellentes résistances normales de quelques microohm.cm^2 et de faible courant de fuite sous le gap de l'ordre du nA. Enfin, nous avons mis en évidence le fonctionnement de ces dispositifs en comptage de photons à la frontière du visible et de l'infrarouge proche (0,78 micron de longueur d'onde). Et même si une meilleure résolution énergétique requiert encore quelques adaptations expérimentales, les détecteurs obtenus sont particulièrement prometteurs pour l'astronomie au sol, des rayons X à l'infrarouge, aussi bien que pour les télécommunications à 1,55 micron où les possibilités des JSET restent sans équivalent.
30

Étude de la tomodensitométrie spectrale quantitative et ses applications en radiothérapie

Simard, Mikaël 02 1900 (has links)
La tomodensitométrie par rayons-X (CT) est une modalité d’imagerie produisant une carte tridimensionnelle du coefficient d’atténuation des rayons-X d’un objet. En radiothérapie, le CT fournit de l’information anatomique et quantitative sur le patient afin de permettre la planification du traitement et le calcul de la dose de radiation à livrer. Le CT a plusieurs problèmes, notamment (1) une limitation au niveau de l’exactitude des paramètres physiques quantitatifs extraits du patient, et (2) une sensibilité aux biais causés par des artéfacts de durcissement du faisceau. Enfin, (3) dans le cas où le CT est fait en présence d’un agent de contraste pour améliorer la planification du traitement, il est nécessaire d’effectuer un deuxième CT sans agent de contraste à des fins de calcul de dose, ce qui augmente la dose au patient. Ces trois problèmes limitent l’efficacité du CT pour certaines modalités de traitement qui sont plus sensibles aux incertitudes comme la protonthérapie. Le CT spectral regroupe un ensemble de méthodes pour produire plusieurs cartes d’atténuation des rayons-X moyennées sur différentes plages énergétiques. L’information supplémentaire, pondérée en énergie qui est obtenue permet une meilleure caractérisation des matériaux analysés. Le potentiel de l’une de ces modalités spectrales, le CT bi-énergie (DECT), est déjà bien démontré en radiothérapie, alors qu’une approche en plein essor, le CT spectral à comptage de photons (SPCCT), promet davantage d’information spectrale à l’aide de détecteurs discriminateurs en énergie. Par contre, le SPCCT souffre d’un bruit plus important et d’un conditionnement réduit. Cette thèse investigue la question suivante : y a-t-il un bénéfice à utiliser plus d’information résolue en énergie, mais de qualité réduite pour la radiothérapie ? La question est étudiée dans le contexte des trois problèmes ci-haut. Tout d’abord, un estimateur maximum a posteriori (MAP) est introduit au niveau de la caractérisation des tissus post-reconstruction afin de débruiter les données du CT spectral. L’approche est validée expérimentalement sur un DECT. Le niveau de bruit du pouvoir d’arrêt des protons diminue en moyenne d’un facteur 3.2 à l’aide de l’estimateur MAP. Celui-ci permet également de conserver généralement le caractère quantitatif des paramètres physiques estimés, le pouvoir d’arrêt variant en moyenne de 0.9% par rapport à l’approche conventionnelle. Ensuite, l’estimateur MAP est adapté au contexte de l’imagerie avec agent de contraste. Les résultats numériques démontrent un bénéfice clair à utiliser le SPCCT pour l’imagerie virtuellement sans contraste par rapport au DECT, avec une réduction de l’erreur RMS sur le pouvoir d’arrêt des protons de 2.7 à 1.4%. Troisièmement, les outils développés ci-haut sont validés expérimentalement sur un micro-SPCCT de la compagnie MARS Bioimaging, dont le détecteur à comptage de photons est le Medipix 3, qui est utilisé pour le suivi de particules au CERN. De légers bénéfices au niveau de l’estimation des propriétés physiques à l’aide du SPCCT par rapport au DECT sont obtenus pour des matériaux substituts à des tissus humains. Finalement, une nouvelle paramétrisation du coefficient d’atténuation pour l’imagerie pré-reconstruction est proposée, dans le but ultime de corriger les artéfacts de durcissement du faisceau. La paramétrisation proposée élimine les biais au niveau de l’exactitude de la caractérisation des tissus humains par rapport aux paramétrisations existantes. Cependant, aucun avantage n’a été obtenu à l’aide du SPCCT par rapport au DECT, ce qui suggère qu’il est nécessaire d’incorporer l’estimation MAP dans l’imagerie pré-reconstruction via une approche de reconstruction itérative. / X-ray computed tomography (CT) is an imaging modality that produces a tridimensional map of the attenuation of X-rays by the scanned object. In radiation therapy, CT provides anatomical and quantitative information on the patient that is required for treatment planning. However, CT has some issues, notably (1) a limited accuracy in the estimation of quantitative physical parameters of the patient, and (2) a sensitivity to biases caused by beam hardening artifacts. Finally, (3) in the case where contrast-enhanced CT is performed to help treatment planning, a second scan with no contrast agent is required for dose calculation purposes, which increases the overall dose to the patient. Those 3 problems limit the efficiency of CT for some treatment modalities more sensitive to uncertainties, such as proton therapy. Spectral CT regroups a set of methods that allows the production of multiple X-ray attenuation maps evaluated over various energy windows. The additional energy-weighted information that is obtained allows better material characterization. The potential of one spectral CT modality, dual-energy CT (DECT), is already well demonstrated for radiation therapy, while an upcoming method, spectral photon counting CT (SPCCT), promises more spectral information with the help of energy discriminating detectors. Unfortunately, SPCCT suffers from increased noise and poor conditioning. This thesis thus investigates the following question: is there a benefit to using more, but lower quality energy-resolved information for radiotherapy? The question is studied in the context of the three problems discussed earlier. First, a maximum a posteriori (MAP) estimator is introduced for post-reconstruction tissue characterization for denoising purposes in spectral CT. The estimator is validated experimentally using a commercial DECT. The noise level on the proton stopping power is reduced, on average, by a factor of 3.2 with the MAP estimator. The estimator also generally con- serves the quantitative accuracy of estimated physical parameters. For instance, the stopping power varies on average by 0.9% with respect to the conventional approach. Then, the MAP estimation framework is adapted to the context of contrast-enhanced imaging. Numerical results show clear benefits when using SPCCT for virtual non-contrast imaging compared to DECT, with a reduction of the RMS error on the proton stopping power from 2.7 to 1.4%. Third, the developed tools are validated experimentally on a micro-SPCCT from MARS Bioimaging, which uses the Medipix 3 chip as a photon counting detector. Small benefits in the accuracy of physical parameters of tissue substitutes materials are obtained. Finally, a new parametrization of the attenuation coefficient for pre-reconstruction imaging is pro- posed, whose ultimate aim is to correct beam hardening artifacts. In a simulation study, the proposed parametrization eliminates all biases in the estimated physical parameters of human tissues, which is an improvement upon existing parametrizations. However, no ad- vantage has been obtained with SPCCT compared to DECT, which suggests the need to incorporate MAP estimation in the pre-reconstruction framework using an iterative reconstruction approach.