• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 195
  • 178
  • 75
  • 20
  • 6
  • 3
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 477
  • 273
  • 92
  • 85
  • 58
  • 57
  • 57
  • 46
  • 46
  • 42
  • 42
  • 40
  • 40
  • 38
  • 38
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Percepção visual de contraste em adultos surdos

Chaves Mendes dos Santos, Liana 31 January 2012 (has links)
Made available in DSpace on 2014-06-12T22:59:27Z (GMT). No. of bitstreams: 2 arquivo9509_1.pdf: 2609026 bytes, checksum: f93d19ba398b37ed340116b687fdcd50 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2012 / O principal objetivo do presente trabalho foi comparar a percepção visual de adultos surdos e adultos com audição normal através da Função de Sensibilidade ao Contraste (FSC). Esta tese foi dividida em dois estudos. Estudo 1: A ideia foi avaliar se a surdez desde o início da infância altera a percepção visual de contraste. Quarenta voluntários, com a mesma faixa etária e de ambos os sexos, participaram da pesquisa. Todos apresentavam a acuidade visual normal ou corrigida. Vinte voluntários eram ouvintes e vinte apresentavam perda auditiva sensório-neural bilateral de grau severo e/ou profundo. Os estímulos visuais estáticos com frequências angulares de 2, 4, 24, 48 e 96 ciclos/360º e de grades senoidais com frequências espaciais de 0,5; 2,5; 4; 10 e 20 cpg (ciclos por grau de ângulo visual) foram apresentados em um monitor de vídeo de 19 polegadas. Foi utilizado o método psicofísico da escolha forçada entre duas alternativas sucessivas, nas quais os estímulos eram exibidos em pares, e os participantes orientados a escolher aquele que continha a frequência espacial (grade senoidal ou angular). O outro estímulo era apenas um círculo cinza com a luminância média. Os voluntários surdos foram instruídos na Língua Brasileira de Sinais. Os resultados demonstraram que os adultos com surdez precisaram de mais contraste do que os adultos ouvintes para perceberem a maioria das frequências espaciais testadas (p < 0,001). Estudo 2: A ideia de verificar se havia alteração na FSC causada pela Síndrome da Rubéola Congênita (SRC) surgiu porque 12 dos 20 participantes da primeira parte deste trabalho apresentavam este diagnóstico etiológico de surdez. Então, as alterações (menor sensibilidade ao contraste para os surdos em quase todas as frequências) poderiam ser causadas pela rubéola que originou a surdez. Os voluntários do primeiro estudo foram divididos em três grupos e dois participantes surdos com a mesma faixa etária, grau e configuração da perda auditiva foram acrescentados ao grupo com surdez causada por outros fatores. Assim, a FSC de 10 adultos com perda auditiva causada pela SRC foi comparada com a de 10 adultos com perda auditiva causada por outros fatores e com a de 10 adultos com audição normal. Foram utilizados os mesmos estímulos visuais e a mesma metodologia do Estudo 1. Os resultados não demonstraram diferença entre a sensibilidade ao contraste das pessoas com perda auditiva causada pela SRC e das pessoas surdas devido a outros fatores (p > 0,05). O grupo com SRC precisou de mais contraste do que as pessoas com audição normal para perceber quase todas as frequências espaciais (p < 0,05). A SRC parece não prejudicar a percepção visual de forma distinta da surdez causada por outras etiologias. Em resumo, os achados desta tese sugerem que a condição da surdez pode causar prejuízos no processamento visual de contraste
52

Efeitos do alcoolismo na percepção visual de contraste

CRUZ, Ellen Dias Nicácio da 31 January 2010 (has links)
Made available in DSpace on 2014-06-12T23:00:37Z (GMT). No. of bitstreams: 2 arquivo737_1.pdf: 1257104 bytes, checksum: 9722b502b35842743379a4cc2a4fc9d3 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2010 / O objetivo desta pesquisa foi investigar os efeitos do alcoolismo na percepção visual de contraste, utilizando a função de sensibilidade ao contraste (FSC), como indicador. Oito voluntários foram inclusos no grupo experimental (GE) e nove, no grupo controle (GC). O GE foi caracterizado por apresentar a síndrome de depêndencia ao álcool, média de 46,7 anos de idade, 63% do sexo masculino, média de tempo de consumo de álcool e abstinência de 18 anos e 13,3 anos, respectivamente. Com exceção de um, todos os participantes do GE eram exfumantes e freqüentavam os Alcoólicos Anônimos. Nenhum voluntário apresentou escore no Inventário de Depressão Beck (BDI) acima do ponto de corte (BDI > 20). O GC não apresentou histórico de consumo de álcool ou de outras substâncias, com 56% dos participantes do sexo feminino e média 42,78 anos de idade. Ambos os grupos tinham a acuidade normal ou corrigida e não possuiam outras patologias diagnósticadas que afetassem as funções ópticas. Todos os voluntários foram submetidos ao método psicofísico da escolha forçada com duas alternativas temporais. Neste paradigma, os voluntários tiveram que decidir qual de dois padrões continha o estímulo teste. O outro estímulo era sempre cinza, com a luminância média (42 cd/m²). A escolha correta era selecionar a frequência grade senoidal cartesiana (0,25; 1; 2; 8 cpg), radial (0,25; 1; 2; 8 cpg) ou angular (3; 24; 48 e 96 ciclos/ 360º). Os padrões tinham um diâmetro de 7,25 graus de ângulo visual, a 150 cm de distância da tela. Os resultados mostraram diferenças significantes entre os GE e GC para as frequências espaciais grades cartesianas de 1 e 2 cpg; para as grades radiais de 0,25; 1 e 2 cpg; e para as grades angulares de 48 e 96 ciclos/ 360º (p < 0,05). Em geral, isto indica que o alcoolismo altera a FSC principalmente nas médias frequências espaciais, mesmo depois de um longo período de abstinência
53

Binarização de Imagens de Documentos Históricos Baseada em Imagem de Contraste

ARRUDA, Alisson Werner Arruda de 27 February 2014 (has links)
Submitted by Lucelia Lucena (lucelia.lucena@ufpe.br) on 2015-03-04T18:27:08Z No. of bitstreams: 2 DISSERTAÇÃO Alisson Werner Arruda.pdf: 4901864 bytes, checksum: ca497864a9da3134128e43273e9f28f3 (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) / Made available in DSpace on 2015-03-04T18:27:08Z (GMT). No. of bitstreams: 2 DISSERTAÇÃO Alisson Werner Arruda.pdf: 4901864 bytes, checksum: ca497864a9da3134128e43273e9f28f3 (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Previous issue date: 2014-02-27 / CAPES / Binarização de imagens de documentos históricos não é uma tarefa trivial, devido aos mais variados problemas pertinentes a este tipo de imagem, tais como a presença de manchas, variação de contraste, iluminação não-uniforme, entre outros. Atualmente, ainda não há uma solução consolidada que resolva esses tipos de problemas com precisão. Métodos atuais geralmente acarretam na perda de elementos de texto e/ou recuperação de elementos do fundo (papel). Tais consequências não são aceitáveis, tendo em vista que documentos históricos podem conter informações de valor inestimável. Um novo algoritmo para binarização de imagens de documentos históricos é apresentado nesta dissertação, a fim de contribuir para a evolução da área em questão. A partir de uma imagem de entrada em tons de cinza, o método propõe o seu mapeamento em duas novas imagens de contraste, que são combinadas para criar uma imagem binarizada "fraca", caracterizada pela exclusão do fundo e de parte do texto. Ao mesmo tempo, é utilizado o algoritmo de limiarização de Valizadeh e Kabir para criar uma imagem binarizada "forte", caracterizada pela preservação máxima do texto, como também parte do fundo. O resultado final da binarização é produzido pela reconstrução da imagem binarizada fraca através da imagem binarizada forte. Uma etapa de pós-processamento é aplicada à imagem binarizada fraca para remover possíveis ruídos. O método proposto foi testado em duas bases bem conhecidas de imagens de documentos, sendo a primeira do DIBCO 2011 (Document Image Binarization Contest), e a segunda do H-DIBCO 2012 (Handwritten Document Image Binarization Contest), ambas contendo diversos tipos de degradação. Os resultados alcançados mostraram-se bastante satisfatórios do ponto de vista qualitativo (visual) e quantitativo (alcançando altos valores em diversas medidas de avaliação).
54

Développement d'agents de contraste intelligents pour l'Imagerie par Résonance Magnétique (IRM) / Development of smart magnetic resonance imaging (MRI) contrast agents

Chauvin, Thomas 16 April 2010 (has links)
L’Imagerie par Résonance Magnétique est une des techniques de diagnostic les plus performantes. Parmi les perspectives d’avenir, les applications en imagerie moléculaire avec l’utilisation d’agents de contraste intelligents sensibles à divers paramètres physico-chimiques sont particulièrement attrayantes.Dans cette thèse, nous présentons la synthèse et la caractérisation physico-chimique de nouveaux complexes de lanthanide dans le but de développer des agents de contraste sensibles à l’activité enzymatique ou la présence d’ions calcium. Les premiers complexes sont basés sur le concept de coupler un substrat spécifique à une enzyme par l’intermédiaire d’un bras auto-immolable, à un chélate de lanthanide macrocyclique. Les modifications de structure qui suivent le clivage du substrat et l’autodestruction du bras sont sensées induire des variations de relaxivité ou des propriétés CEST des complexes. Même si nous n'avons pas pu créer des agents de GdIII avec une réponse T1, plusieurs complexes d’YbIII ou d’EuIII montrent un important changement de leurs propriétés CEST après réaction enzymatique. Certains d'entre eux portant un bras dérivé pyridinique peuvent également agir comme des sondes optiques émettant dans le visible ou le proche infrarouge.Nous avons également développé un agent sensible au calcium en combinant un chélate de lanthanide macrocyclique avec une unité d’iminodiacetate permettant la coordination du calcium. Les complexes d’EuIIIet d’YbIII montrent une importante diminution de l’effet CEST en présence de Ca2+. L’utilisation en parallèle des deux complexes permet une approche ratiométrique où la réponse IRM détectée est indépendante de la concentration de l’agent. / Today, Magnetic Resonance Imaging is one of the most powerful diagnostic techniques in the clinics. Amongfuture perspectives, molecular imaging applications based on smart contrast agents which are responsive to various physico-chemical parameters, are particularly attractive. In this work, we present the synthesis and physico-chemical characterisation of novel lanthanide complexes with the aim of developing smart contrast agents for the detection of enzyme activity or calcium concentration.The complexes designed to give an MRI response to an enzyme are based on the original concept of coupling an enzyme-specific substrate to a macrocyclic LnIII chelate via a self-immolative linker. The structural changes following enzymatic cleavage of the substrate and destruction of the self-immolative armare expected to induce variation of the relaxivity or the CEST properties of the LnIII complexes. Though we failed creating GdIII agents with a T1 response upon enzymatic reaction, several YbIII or EuIII complexes were synthesized that provide an important change in their CEST properties. Some of them, bearing a pyridine-derivative arm which is an efficient sensitizer of lanthanide luminescence, act also as enzyme-responsive NIR or visible emitting optical probes.We have developed a Ca-responsive agent combining a DOTA-tetraamide LnIII chelator with animinodiacetate unit for calcium coordination. The EuIII and YbIII complexes show an important decrease in the CEST effect in response to Ca2+. The parallel application of the two complexes allows for ratiometric approaches where the detected MRI response is independent of the concentration of the agent.
55

Estimation de la visibilité routière du point de vue du conducteur : contribution aux aides à la conduite / Estimation of road visibility from the human perception : contribution to driving assistance systems

Joulan, Karine 21 September 2015 (has links)
Les aides à la conduite sont des systèmes qui aident le conducteur à mieux appréhender la tâche de conduite en situation difficile. Parmi les différents capteurs qu'utilisent ces ADAS, des caméras sont embarquées et délivrent des images de la scène routière qui sont traitées et analysées de manière à informer le conducteur des dangers éventuels ou enclencher des systèmes d'urgence. Les caméras issues de ces ADAS capturent l'environnement routier d'une manière qui est loin d'être représentative de la perception qu'aurait un conducteur. Une des conséquences éventuelles est que ces ADAS soient contre-productives en déclenchant inopinément des systèmes d'alerte et d'action à l'encontre du conducteur. De manière à remplir complétement la vocation de ces ADAS, il est primordial de disposer d'une carte de la perception de l'environnement routier du point de vue du conducteur de manière à ajuster l'aide dont il pourrait avoir besoin. Nous proposons d'estimer par traitement d'image, la visibilité routière du point de vue du conducteur en utilisant un algorithme bio-inspiré simulant la sensibilité au contraste de l'œil humain. Dans un premier temps, nous étendons un modèle de CSF (Contrast Sensitivity Function) de manière à prendre en compte des taux de détection cohérents avec la sécurité routière, l'orientation, la couleur et l'âge du conducteur. Dans un second temps, nous modélisons notre modèle de CSF par un filtrage spatial et en calculons la visibilité en chaque pixel de l'image. Nous appliquons cette carte de visibilité sur une carte de contours issue de notre détecteur de contour bio-inspiré. Ainsi, nous considérons les contours des objets routiers présents dans l'image plutôt que leurs caractéristiques de manière à éviter toute hypothèse. Ces contours sont associés à un niveau de visibilité indiquant s'ils sont visibles ou pas par l'observateur. Nous validons le procédé en le comparant à des performances visuelles d'observateurs, en condition de laboratoire, pour une détection de cible et en situation de conduite simulée en conduite de nuit. Dans un deuxième temps, nous associons ces niveaux de visibilité en deux unités facilement compréhensibles pour des ADAS: un temps de réaction et une distance perçue. En premier lieu, nous proposons un modèle d'estimation du temps de perception du conducteur en fonction de la visibilité en nous inspirant de la loi de Piéron sur des données expérimentales de détection de cibles sur des images routières de synthèse pour une certaine densité de brouillard de jour. Les études ont montré que les conducteurs auraient tendance à se rapprocher du véhicule devant eux de manière à ne pas les perdre de vue. Ce constat nous renseigne sur le fait que le conducteur ne dispose pas suffisamment de visibilité à ses yeux dans cette configuration de conduite. Nous montrons l'intérêt des méthodes de restauration d'images en termes de gain de temps de réaction et de performance visuelle comme le taux de détection du véhicule devant lui. Dans un second temps, nous estimons une distance par rapport au véhicule précédent du point de vue du conducteur en nous inspirant de la détection des feux arrière du véhicule situé devant le conducteur. Les résultats ont montré que les conducteurs estimaient mal les distances sur obstacles lointains en comparaison des aides à la conduite basées sur des imageurs optique, radar ou lidar pour une conduite de nuit. D'après ce constat, les ADAS jouent un rôle fondamental pour prévenir le conducteur de sa conduite inadaptée. Enfin, nous délimitons les limites de nos modèles de CSF et de visibilité et proposons plusieurs perspectives. Pour des applications routières, une des perspectives qui a été concrétisée partiellement est l'évaluation objective des systèmes d'éclairage par notre modèle de visibilité et sa cohérence avec une expertise subjective / The driver assistance systems are systems that help the driver to better understand the plight driving task. Among the various sensors used by these ADAS, cameras are shipped and deliver images of the road scene which are processed and analyzed to inform the driver of potential hazards or switch of emergency systems. The cameras capture from these ADAS is far from representative of perception would have a driver. One of the possible consequences is that these ADAS can be counter productive in triggering warning and action against the driver. In order to completely fulfill the objectives of such ADAS, it is essential to have a map of the perception of the road environment from the perspective of the driver to adjust the help they might need. We propose to estimate by image processing, road visibility from the driver's perspective using a bio-inspired algorithm simulating the contrast sensitivity of the human eye. First, we extend a model of CSF (Contrast Sensitivity Function) to consider coherent detection rate with road safety, orientation, color and age of the driver. In a second step, we model our CSF spatial filtering and calculate the visibility for each pixel of the image. We apply this visibility map on a map of contours of our bio-inspired edge detector. Thus, we consider the contours of the road objects in the image rather than the characteristics in order to avoid assumptions. These contours are associated with a level of visibility as to whether or not they are visible by the observer. We validate the method by comparing it with the visual performance of observers in laboratory conditions for target detection and simulated driving situation in night driving. Secondly, we combine these two levels of visibility in easily understandable units for ADAS: a reaction time and a target distance. First, we propose a model to estimate the driver's reaction time depending on the visibility (inspired by Piéron's law of target detection) with experimental data on road synthetic images for some daylight fog density. Studies have shown that drivers would tend toget closer to the vehicle in front of them in order not to lose sight of them. This observation tells us that the driver does not have enough visibility in that configuration. We show the interest of the image restoration methods in terms of reaction time and gain in visual performance as well as vehicle detection rate. In a second step, we estimate a distance from the point of view of the driver taking inspiration from the detection of the rear lights of the vehicle in front of the driver. The results showed that drivers were bad about the distance evaluation of distant obstacles compared to driving aids based on optical imaging, radar or lidar for night driving. Based on this observation, the ADAS may play a fundamental role in preventing the driver from his inappropriate behavior. Finally, we outline the limits of our models CSF and visibility and offer several perspectives for road applications, one of which was the objective evaluation of lighting systems by our model of visibility and consistency with a subjective expertise
56

Nanoparticules incorporant des complexes inorganiques à visée diagnostique / Metal complexes-loaded nanoparticles for diagnostic and medical imaging

Courant, Thomas 15 March 2011 (has links)
L’objectif poursuivi au cours de ce travail est l’encapsulation de complexes métalliques au sein de nanoparticules biocompatibles, et ce pour des visées diagnostiques. Dans ce but, un protocole de double émulsion-diffusion de solvant Wi/O/We, n’utilisant que des composés biocompatibles, a été mis au point et optimisé pour obtenir, de façon quantitative et reproductible, des nanoparticules de PLGA de diamètre compatible avec une injection par voie parentérale. Cette formulation a été employée avec succès pour l’encapsulation de complexes modèles de Cu(II). Les formulations optimales permettent d’obtenir des nanoparticules possédant des diamètres hydrodynamiques moyens inférieurs à 200 nm avec des efficacités d’encapsulation entre 20 et 25 %. L’utilisation de cette formulation pour l’encapsulation de chélates de gadolinium ne permet pas d’obtenir des rendements d’encapsulation satisfaisants. La modification du protocole vers une méthodologie Wi/O1/O2ne permet pas d’améliorer l’encapsulation et dénote l’absence d’affinités entre le polymère hydrophobe et les complexes hydrophiles. L’utilisation de nanoparticules composées d’une matrice hydrophile permet d’obtenir des taux de charges nettement supérieurs. Ceci conforte l’hypothèse selon laquelle les interactions entre le complexe et la matrice des nanoparticules jouent un rôle crucial pour l’encapsulation. / The goal of this work was to encapsulate metal complexes into biocompatible nanoparticles for diagnostics. To reach this purpose, a double emulsion-solvent diffusion Wi/O/We technique was optimized, using only biocompatible compounds. It allowed the obtention of PLGA nanoparticles that are compatible with parenteral injections in a reproducible and quantitative way. This formulation was successfully applied to encapsulate model Cu(II)complexes. Optimal formulations showed mean diameters below 200 nm with encapsulation yields in the 20-25 % range. The use of this formulation for gadolinium chelates did not lead to satisfactory encapsulation yields. Thereafter, a Wi/O1/O2 methodology was developed but could not allow to raise the encapsulation efficiencies. This point showed the lack of affinity between the hydrophobic polymer and the hydrophilic chelates. The use of nanoparticles made of an hydrophilic matrix showed a ten-fold increase in the drug loading efficiency. This confirms the hypothesis in which interactions between chelates and nanoparticle matrices play a crucial role for encapsulation.
57

Development of quantitative methods for the following of tumoral angiogenesis with dynamic contrast-enhanced ultrasound / Développement de methodes quantitatives pour le suivi de l'angiogenese tumorale par échographie de contraste ultrasonore

Barrois, Guillaume 30 September 2014 (has links)
L'objectif de ce travail était de développer des méthodes pour permettre une évaluation in vivo plus robuste du réseau vasculaire dans la tumeur par imagerie de contraste ultrasonore. Trois aspects de l'analyse de donnée ont été abordé: 1) la régression des modèles paramétriques de flux sur les données de puissance linéaire, 2) la compensation du mouvement 3) l’évaluation d’une méthode de clustering pour identifier les hétérogénéités dans les tumeurs. Un modèle multiplicatif est proposé pour décrire le signal DCE-US. Une méthode de régression en est dérivée. La caractérisation du signal permet la mise au point d’une méthode de simulation de séquences 2D+T. La méthode de régression permet une diminution de la variabilité des paramètres de flux fonctionnels extraits, sur données simulées expérimentales. La méthode de simulation est appliquée pour évaluer une méthode combinant estimation du mouvement et estimations des paramètres micro-vasculaires dans un unique problème mathématique d'optimisation. Cette nouvelle méthode présente en plus l'avantage d'être indépendante de l'opérateur. Il est montré que dans une large majorité des cas l'estimation du mouvement est meilleure avec la nouvelle méthode qu'avec une méthode de références. Une méthode de clustering est adaptée et évaluée sur données DCE-US simulées et in-vivo. Elle permet de détecter des hétérogénéités dans la structure vasculaire des tumeurs. Les méthodes développées permettent d'améliorer l’évaluation du réseau microvasculaire par DCE-US grâce à une description rigoureuse du signal, à la mise au point d'outil diminuant l'intervention de l'opérateur et la prise en compte de l'hétérogénéité du réseau vasculaire. / This work aimed to develop methods to robustly evaluate in vivo functional flow within the tumor vascular network with Dynamic contrast-enhanced ultrasound (DCE-US). Three aspects of data analysis were addressed: 1) insuring best fit between parametric flow models and the experimentally acquired echo-power curves, 2) compensating sequences for motion and 3) evaluating a method to discriminate between tissues with different functional flow. A multiplicative model is proposed to describe the DCE-US signal. Based on this model, a new parametric regression method of the signal is derived. Characterization of the statistical properties of the noise and signal is also used to develop a new method simulating contrast-enhanced ultrasound 2D+t sequences. A significant decrease in the variability of the functional flow parameters extracted according to the new multiplicative-noise fitting method is demonstrated using both simulated and experimentally-acquired sequences. The new sequence simulations are applied to test a method combining motion estimation and flow-parameter estimation within a single mathematical framework. Because this new method does not require the selection of a reference image, it reduces operator intervention. Tests of the method on both simulations and clinical data and demonstrate in a majority of sequences a more accurate motion estimation than the commonly used image registration method. Finally, a non-parametric method for perfusion curve clustering is evaluated on 2D+t sequences. The aim of this method is to regroup similar filling patterns without a priori knowledge about the patterns. The method is tested on simulated and on pre-clinical data.
58

Estudo ultrassonográfico da perfusão renal em cadelas com carcinoma mamário tratadas com carprofeno por longos períodos /

Estrada, Cristhian Rene Vargas January 2020 (has links)
Orientador: Andrigo Barboza De Nardi / Resumo: Os anti-inflamatórios não esteroidais (AINEs) COX-2 seletivos possuem efeito antitumoral mais potente que os AINEs tradicionais e desencadeiam menos efeitos colaterais. Dentre estes efeitos indesejáveis cabe citar alterações gastrintestinais e da perfusão renal, quando administrados por longos períodos para o tratamento auxiliar da dor ou do próprio câncer. Com estes preceitos hipotetizou-se que o carprofeno como AINEs seletivo usado por um período de três meses tem um efeito benéfico em pacientes afetados por carcinoma mamário e que os efeitos sobre o sistema renal vão ser moderados e apenas ligados à alteração da perfusão renal e não à alteração de sua função, assim, objetivou-se avaliar a hemodinâmica renal por meio das técnicas ultrassonográficas Doppler e ultrassonografia contrastada por microbolhas (CEUS), os parâmetros clínicos e laboratoriais rotineiros de função renal e a evolução clínica de cadelas com carcinomas mamário, submetidas à mastectomia, e tratadas ou não com carprofeno. Foi realizado um estudo clínico prospetivo, aleatorizado em 26 cadelas, distribuídas equitativamente em um grupo tratado que recebeu carprofeno 4,4 mg/kg/dia por 90 dias e um grupo controle que não recebia medicação anti-inflamatória. Foram obtidos os parâmetros Dopplerfluxométricos da artéria renal, caraterísticas da perfusão renal pela CEUS, análises celulares e bioquímicas hematológicas e analise clínicas uma vez por mês durante seis meses. Estes dados foram submetidos a comparação entr... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Selective COX-2 nonsteroidal anti-inflammatory drugs (NSAIDs) have a more potent antitumoral effect than traditional NSAIDs and trigger fewer side effects. Among these undesirable effects, it is important mentioning gastrointestinal and renal perfusion changes, when administered for long periods in the auxiliary treatment of pain or cancer. With these precepts, it was hypothesized that carprofen as selective NSAIDs used for a period of three months has a beneficial effect on patients affected by breast carcinoma and that the effects on the renal system will be moderate, linked only to renal perfusion alteration and not to function alteration, consequently, the objective was to evaluate renal hemodynamics by Doppler ultrasound and microbubbles contrast enhancement ultrasound (CEUS) techniques, routine clinical and laboratorial parameters of renal function and clinical evolution of bitches with breast carcinomas, submitted to mastectomy, and treated or not with carprofen. A prospective, randomized clinical study was carried out on 26 bitches, equally distributed in a treated group that received carprofen 4.4 mg/kg/day for 90 days and a control group that did not receive NSAIDs medication. Dopplerfluxometric parameters of the renal artery, CEUS renal perfusion characteristics, cell and biochemical hematological analysis and clinical analysis were obtained once a month for six months. These data were subjected to comparison between groups and moments by analysis of variance (ANOV... (Complete abstract click electronic access below) / Mestre
59

Synthèse de nanoparticules magnétiques en milieu aqueux par plasma à pression atmosphérique : applications comme agent de contraste en imagerie par résonance magnétique

Létourneau, Mathieu 23 April 2018 (has links)
Les nanoparticules ultrafines d’oxyde ou d’hydroxyde de fer utilisées en imagerie par résonance magnétique (IRM) permettent de rehausser le signal vasculaire. Dans ce projet, des nanoparticules magnétiques ultrafines (&lt; 10 nm) à base de fer sont synthétisées à l’aide d’une méthode de réduction par électrochimie plasma-liquide (EPL). Simple et rapide (t &lt; 5 min.), cette méthode consiste à projeter un plasma d’argon à la surface d'une solution aqueuse contenant des ions métalliques et des molécules de ligand. Une fois purifiées par chromatographie ou par dialyse, la suspension de nanoparticules permet d'obtenir un contraste positif en IRM. Une préparation de ces nanoparticules a été injectée in vivo (modèle de la souris), permettant de démontrer un fort rehaussement du signal vasculaire. Cette technologie pourrait avantageusement être appliquée dans les centres hospitaliers, afin de produire un agent de contraste biocompatible sur place et sur demande. / Ultra-small iron oxide and hydroxide nanoparticles can be used to enhance vascular signal in magnetic resonance imaging. In this project, ultra small iron hydroxide magnetic nanoparticles (&lt; 10 nm) are synthesized with a plasma-liquid electrochemical method. Rapid and simple (t &lt; 5 min.), this technique consists of an argon microplasma directed to an aqueous solution containing metal ions and ligand molecules. Synthesizing nanoparticles directly in water is advantageous in the context of biomedical applications. After purification with size-exclusion chromatography or dialysis, the nanoparticle suspension allowed to obtain positive contrast enhancement in MRI. Finally, the prepared nanoparticles were injected in vivo (in the mouse model) enabling a high increase of vascular signal. This technology could be favourably installed in hospitals, in order to produce a biocompatible MRI contrast agent, on site and on demand.
60

ETUDE DE LA PERFUSION EN ECHOGRAPHIE DE CONTRASTE

Renault, Gilles 01 February 2006 (has links) (PDF)
L'ECHOGRAPHIE DE CONTRASTE EST UNE MODALITE EN DEVELOPPEMENT POUR L'ESTIMATION DE LA PERFUSION. SA QUANTIFICATION RESTE DIFFICILE DU FAIT DE DIFFERENTS PROBLEMES. EN EFFET, LES ACQUISITIONS PEUVENT ÊTRE SOUMISES A DES MOUVEMENTS RESPIRATOIRES ET LA RELATION ENTRE LE SIGNAL AFFICHE DANS L'IMAGE ET LA CONCENTRATION DU PRODUIT DE CONTRASTE ULTRASONORE (PCUS) EST ENCORE ASSEZ MAL CONNUE. CE TRAVAIL PROPOSE D'AIDER A IDENTIFIER LES DIFFERENTES CINETIQUES DE PRISE DE CONTRASTE DANS LES SEQUENCES D'ECHOGRAPHIE DE CONTRASTE NOTAMMENT PAR L'EMPLOI DE L'ANALYSE FACTORIELLE DES SEQUENCES D'IMAGES MEDICALES (AFSIM). CETTE METHODE PERMET D'IDENTIFIER LES DEFICITS DE PERFUSION AINSI QUE DES PHENOMENES DE MASQUAGE DES ZONES PROFONDE PAR LE PCUS EN ECHOGRAPHIE DE CONTRASTE CEREBRALE. L'AFSIM MONTRE AUSSI L'INFLUENCE DU MOUVEMENT RESPIRATOIRE DANS LES SEQUENCES DE PERFUSION HEPATIQUE ET CHEZ LA SOURIS. UNE COMPENSATION DE CE MOUVEMENT EST PROPOSEE EN SYNCHRONISANT LES IMAGES SUR LE CYCLE RESPIRATOIRE, ESTIME A POSTERIORI PAR UN CRITERE D'INDEPENDANCE STATISTIQUE OU UN CRITERE FREQUENTIEL. CETTE SYNCHRONISATION GENERE DES SEQUENCES D'IMAGES CONTENANT PEU DE MOUVEMENTS RESIDUELS ET REDUIT LES EFFETS DE VOLUME PARTIEL. POUR COMPENSER LES PHENOMENES DE MASQUAGE, LES COEFFICIENTS DE RETRO-DIFFUSION HARMONIQUE ET D'ATTENUATION ONT ETE EXPLORES IN VITRO, EN FONCTION DE L'INDEX MECANIQUE EMPLOYE ET DE LA CONCENTRATION DE PCUS. UNE SOLUTION SIMPLE DE COMPENSATION DE CE PHENOMENE EST PROPOSEE DANS LE CAS PARTICULIER DES ECHOGRAPHIES CEREBRALES. CE TRAVAIL CONSTITUE UNE PREMIERE ETAPE AFIN DE MIEUX COMPRENDRE ET COMPENSER LES OBSTACLES A LA QUANTIFICATION EN ECHOGRAPHIE DE CONTRASTE.

Page generated in 0.0409 seconds