• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 195
  • 178
  • 75
  • 20
  • 6
  • 3
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 477
  • 273
  • 92
  • 85
  • 58
  • 57
  • 57
  • 46
  • 46
  • 42
  • 42
  • 40
  • 40
  • 38
  • 38
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Aplicação da Transformada de Wavelet para realce de estruturas em imagens mamográficas / not available

Pereira Junior, Roberto Rodrigues 30 July 1999 (has links)
Este trabalho apresenta um estudo sobre a utilização da Transformada de Wavelet para o realce de contraste de estruturas de interesse mamográfico (nódulos e microcalcificações), visando o desenvolvimento de um sistema computacional para auxílio ao diagnóstico do câncer de mama. Este sistema compõe-se basicamente de 3 etapas: pré-processamento, detecção e classificação, sendo que este trabalho insere-se na etapa de pré-processamento. Nessa etapa as estruturas de interesse foram realçadas de forma a propiciar um melhor desempenho nas etapas seguintes. No trabalho aqui descrito as estruturas de interesse contidas em mamogramas digitalizados foram realçadas pela Transformada de Wavelet através de dois métodos distintos: Ganho Adaptativo Multiescala e Reconstrução Parcial. Na técnica Ganho Adaptativo Multiescala a imagem é decomposta em sub-imagens pela Transformada de Wavelet. As sub-imagens decompostas são realçadas por uma função não linear e então a imagem realçada é obtida pela aplicação da Transformada Inversa de Wavelet. Na técnica Reconstrução Parcial, a imagem é decomposta em sub-imagens pela Transformada de Wavelet. São selecionadas as sub-imagens onde as estruturas de interesse são mais representativas e então a imagem realçada é obtida pela aplicação da Transformada Inversa de Wavelet à estas sub-imagens. A avaliação dos resultados é feita por um quantificador da melhoria de contraste das imagens e pela análise do histograma. / In the present work, we presents a study about using of Wavelet Transform in contrast enhancement of mammographic features(mass and microcalcifications), as part of developing a Computerized System proposed to aid in diagnosis of breast cancer. This system is composed of 3 main stages: early processing, detection and classification, and this work is into the early processing stage. In this stage structures of interest have been enhanced to improve performance at following stages. In this work, mammographic features have been enhanced by application of 2 distinct methods using Wavelet Transform: Multiscale Adaptive Gain and Partial Reconstruction. Multiscale Adaptive Gain decomposes the original image in subimages by application of Wavelet Transform. These subimages are enhanced throw the application of a non linear function and the enhanced image is obtained by application of Inverse Wavelet Transform. Partial Reconstruction decomposes the original image in subimages by application of Wavelet Transform. The subimages more representative for mammographic features are selected and the enhanced image is obtained by application of lnverse Wavelet Transform in these subimages. The final results obtained are evaluated by a Contrast Improvement Quantifier and histogram analysis.
32

Desenvolvimento da sensibilidade ao contraste de luminância espacial e temporal / SMCF Development of spatial and temporal luminance contrast sensitivity

Moreira, Sonia Maria Cipriani Fersura 31 August 2010 (has links)
Objetivo: Avaliar a Função de Sensibilidade ao Contraste de Luminância Espacial e Temporal, estudar o desenvolvimento destas funções, a contribuição das vias de processamento paralelo para as funções de Sensibilidade ao Contraste e seu respectivo desenvolvimento e, por fim, determinar valores normativos destas funções visando uma aplicabilidade clínica.Método A avaliação psicofísica de sensibilidade ao contraste de luminância espacial e temporal foi realizada em 112 sujeitos divididos em três grupos:GrupoI ( idade média =9,14±2,7 anos),Grupo II ( idade média=23,7 ± 3,4 anos) e Grupo III ( idade média=41,8± 5,5 anos) com o programa PSYCHO for Windows Versão 2.36 (Cambridge Research Systems, CRS-Ltd, UK) acoplado a um microcomputador PC XTC -600. . Os estímulos foram apresentados em um monitor Sony Triniton de 19 polegadas GFD420 (Sony Corporation, USA) com resolução espacial de 800X600 e resolução temporal de 69 Hz Os estímulos eram comandados pela placa gráfica VSG 2/4 (Cambridge Research Systems, CRS-Ltd, UK).Resultados A avaliação psicofísica para a sensibilidade ao contraste espacial e temporal mostraram que esta função já está desenvolvida e em pleno funcionamento em crianças (6 anos) ocorrendo um declínio para as frequências espaciais de 2,0cpg;8,3cpg e 14,5cpg para os grupos II e III.Para a frequência temporal de 2,5Hz o declínio ocorre nos Grupos II e III e para a frequência temporal de 5,0 Hz nas idades mais avançadas(GIII). Para o estudo da contribuição das vias de processamento paralelo (magnocelular e parvocelular) podemos notar uma maior sensibilidade ao contraste para decremento de luz do que para incremento de luz, porém não foi possível determinar a real contribuição dessas vias para a função de sensibilidade ao contraste. Conclusão Avaliamos com sucesso a Sensibilidade ao Contraste Espacial e Temporal para todas as faixas etárias e, assim, conseguimos ter acesso ao desenvolvimento desta função, entre as idades de 6 e 57 anos. Valores normativos para as tais funções foram estabelecidos por metodologia nãoparamétrica.. O estudo da contribuição das vias magnocelular e parvocelular não pode ser conclusivo, porém os achados mostraram uma maior sensibilidade para o decremente de luz o que corrobora com a literatura / Purpose: To analyze the spatial and temporal luminance contrast sensitivity function, to study the development of these functions, the contribution of the parallel processing pathways and to determine the normative values of these functions to order a clinical applicability normative. Methods the psychophysical evaluation of the spatial and temporal luminance contrast sensitivity was performed in 112 subjects divided into three groups: Group I (mean age =9.14±2.7 years), Group II (mean age=23.7 ± 3.4 years) and Group III (mean age=41.8± 5.5 years) with the PSYCHO for Windows Version 2.36 (Cambridge Research Systems, CRS-Ltd, UK) connect to the microcomputer PC XTC -600. The stimuli was showed in a monitor Sony Triniton de 19 inches GFD420 (Sony Corporation, USA) with spatial resolution of the 800X600 and temporal resolution of the 69 Hz. The stimuli was made by the graphics card VSG 2/4 (Cambridge Research Systems, CRS-Ltd, UK).Results The psychophysics evaluation to spatial and temporal contrast sensitivity showed that this function is already developed and full operation in children (6 years old) with a decline to spatial frequencies of 2.0cpg;8.3cpg and 14.5 cpg to the groups II and III. For the temporal frequency of 2.5Hz the decline occur to the groups II and III .and to the temporal frequency of 5.0 Hz the decline occur to the advantage ages(GIII). For the study of the parallel processing pathways (magnocellular e parvocellular) we can see bigger contrast sensitivity to decrement than to increment of light. It was not possible determine the real contribution of these pathways to the contrast sensitivity function. Conclusion We evaluated in a successful way the spatial and temporal contrast sensitivity to all age range and so we could access the development of this function between the ages from 6 to 57 years old. Normatives values to this function were established for non parametric methodology. The study of the contribution of the parvocellular and magnocellular pathways is not conclusive, but the results showed a bigger sensibility to decrement than to increment of light that was similar to the literature
33

Nanopartículas antiferromagnéticas de MnO para aplicações em biomedicina como agentes de contraste / Antiffeomagnetic MNo nanoparticles for applications in biomedicine as a contrast agent

Neves, Herbert Rodrigo 24 February 2012 (has links)
Nanomateriais têm sido amplamente estudados, como resultado de suas propriedades físicas e químicas diferenciadas, que oferecem um grande número de possibilidades para aplicações em biomedicina, principalmente na terapia de câncer e no desenvolvimento de estratégias de diagnóstico não invasivo. O óxido de ferro superparamagnético (SPION) é o principal material estudado como agente de contraste para imagem por ressonância magnética, devido à sua capacidade de reduzir o tempo de relaxação transversal (T2) em diferentes tecidos e sua menor toxicidade que os complexos de Gd3+ e Mn2+ usados atualmente. Entretanto, o acumulo de SPIONs pode ser facilmente confundido com sinais referentes à calcificação, depósito de metais pesados e sangramentos, e a alta susceptibilidade magnética do material promove distorções na imagem. Assim, alguns aspectos são desejáveis em material para que este tenha potencial para substituir o SPION, tais como forma nanoparticulada, para fácil modificação de superfície e possibilidade de funcionalização com agentes biosseletivos, e contraste positivo em T1. As nanopartículas (NPs) antiferromagnéticas de MnO atendem a todos os requisitos necessários para substituir o óxido de ferro. As NPs de MnO foram sintetizadas a partir da decomposição térmica do acetilacetonato de manganês(II) em uma variação do método poliol modificado, resultando na formação de NPs com tamanho médio de 21 ± 3,9 nm. Foi realizada a substituição de ligantes de superfície para que se substituísse o ácido oleico adsorvido sobre o material por 3-aminopropiltrimetoxisilano (APTMS) e foi determinada a concentração de grupamentos amino sobre a superfície das NPs. Posteriormente, obteve-se uma estrutura do tipo \"core/shell\" dispersível em meio aquoso e biocompatível pela reação dos grupos amino livres com o carboxilato da carboximetil dextrana (CMDex). O potencial de superfície e a estabilidade coloidal das NPs funcionalizadas foram caracterizados por mobilidade eletroforética e por espalhamento de luz dinâmico em água deionizada e em condições que mimetizavam o sangue. As NPs apresentaram toxicidade em células cancerosas de carcinoma cervical humano (HeLa). Entretanto, não foi observada toxicidade significativa na linhagem de células não cancerosas NCTC clone L929. Tanto as NPs como sintetizadas quanto as recobertas com CMDex apresentaram controle de tamanho e forma, apresentando distribuição de tamanho compatível com o esperado para as aplicações em biomedicina. / Nanomaterials have been widely studied as a result of their interesting physical and chemical properties, which offer a large number of possibilities for applications in biomedicine mainly in cancer therapy and the development of strategies for non-invasive diagnosis. The superparamagnetic iron oxide nanoparticles (SPION) is the main studied material as contrast agent for magnetic resonance imaging (MRI) due to its ability to reduce the transverse relaxation time (T2) in different tissues and lower toxicity than Gd3+ and Mn2+ complexes currently used. However, this SPIONs accumulation can be confused with signals from calcification, bleeding or metal deposits, and the high magnetic susceptibility distorts the background image because its ferromagnetic behavior. Some aspects are desirable to replace SPIONs, such as nanoparticulate form for simple surface modification and labeling with targeting agents, and positive longitudinal T1 relaxation time contrast ability. The antiferromagnetic MnO NPs attend all these requirements and overcome the drawback of using SPION. In our study, MnO NPs were synthesized by the thermal decomposition of Mn(II) acetylacetonate by a variation of the modified polyol process resulting in spherical nanoparticles with average size of 21 ± 3,9 nm. The ligand-exchange step was used to replace the oleic acid adsorbed on the as-synthesized NPs surface by 3-aminopropyltriethoxysilane (APTMS) and the total free amine groups on the NPs surface was determined. After that, a biocompatible and water-dispersible core/shell structure was obtained by coating with carboxymethyl dextran (CMDex) using the free amine-terminal group from APTMS and the carboxylate groups present in the CMDex molecules conjungation. Surface potential and colloidal stability of these functionalized NPs were evaluated by electrophoretic mobility and dynamic light scattering techniques in both water and artificial blood by using the Simulated Body Fluid (SBF) medium. While the water-dispersible NPs have shown toxicity in the human cell line derived from cervical cancer (HeLa), they have not shown significantly cytotoxicity in the healthy fibroblast cells (cell line L929). Both the as-synthesized and coated NPs present controlled size and shape and the final NPs size distribution and magnetic properties are compatible with the expected for biomedical applications.
34

Desenvolvimento da sensibilidade ao contraste de luminância espacial e temporal / SMCF Development of spatial and temporal luminance contrast sensitivity

Sonia Maria Cipriani Fersura Moreira 31 August 2010 (has links)
Objetivo: Avaliar a Função de Sensibilidade ao Contraste de Luminância Espacial e Temporal, estudar o desenvolvimento destas funções, a contribuição das vias de processamento paralelo para as funções de Sensibilidade ao Contraste e seu respectivo desenvolvimento e, por fim, determinar valores normativos destas funções visando uma aplicabilidade clínica.Método A avaliação psicofísica de sensibilidade ao contraste de luminância espacial e temporal foi realizada em 112 sujeitos divididos em três grupos:GrupoI ( idade média =9,14±2,7 anos),Grupo II ( idade média=23,7 ± 3,4 anos) e Grupo III ( idade média=41,8± 5,5 anos) com o programa PSYCHO for Windows Versão 2.36 (Cambridge Research Systems, CRS-Ltd, UK) acoplado a um microcomputador PC XTC -600. . Os estímulos foram apresentados em um monitor Sony Triniton de 19 polegadas GFD420 (Sony Corporation, USA) com resolução espacial de 800X600 e resolução temporal de 69 Hz Os estímulos eram comandados pela placa gráfica VSG 2/4 (Cambridge Research Systems, CRS-Ltd, UK).Resultados A avaliação psicofísica para a sensibilidade ao contraste espacial e temporal mostraram que esta função já está desenvolvida e em pleno funcionamento em crianças (6 anos) ocorrendo um declínio para as frequências espaciais de 2,0cpg;8,3cpg e 14,5cpg para os grupos II e III.Para a frequência temporal de 2,5Hz o declínio ocorre nos Grupos II e III e para a frequência temporal de 5,0 Hz nas idades mais avançadas(GIII). Para o estudo da contribuição das vias de processamento paralelo (magnocelular e parvocelular) podemos notar uma maior sensibilidade ao contraste para decremento de luz do que para incremento de luz, porém não foi possível determinar a real contribuição dessas vias para a função de sensibilidade ao contraste. Conclusão Avaliamos com sucesso a Sensibilidade ao Contraste Espacial e Temporal para todas as faixas etárias e, assim, conseguimos ter acesso ao desenvolvimento desta função, entre as idades de 6 e 57 anos. Valores normativos para as tais funções foram estabelecidos por metodologia nãoparamétrica.. O estudo da contribuição das vias magnocelular e parvocelular não pode ser conclusivo, porém os achados mostraram uma maior sensibilidade para o decremente de luz o que corrobora com a literatura / Purpose: To analyze the spatial and temporal luminance contrast sensitivity function, to study the development of these functions, the contribution of the parallel processing pathways and to determine the normative values of these functions to order a clinical applicability normative. Methods the psychophysical evaluation of the spatial and temporal luminance contrast sensitivity was performed in 112 subjects divided into three groups: Group I (mean age =9.14±2.7 years), Group II (mean age=23.7 ± 3.4 years) and Group III (mean age=41.8± 5.5 years) with the PSYCHO for Windows Version 2.36 (Cambridge Research Systems, CRS-Ltd, UK) connect to the microcomputer PC XTC -600. The stimuli was showed in a monitor Sony Triniton de 19 inches GFD420 (Sony Corporation, USA) with spatial resolution of the 800X600 and temporal resolution of the 69 Hz. The stimuli was made by the graphics card VSG 2/4 (Cambridge Research Systems, CRS-Ltd, UK).Results The psychophysics evaluation to spatial and temporal contrast sensitivity showed that this function is already developed and full operation in children (6 years old) with a decline to spatial frequencies of 2.0cpg;8.3cpg and 14.5 cpg to the groups II and III. For the temporal frequency of 2.5Hz the decline occur to the groups II and III .and to the temporal frequency of 5.0 Hz the decline occur to the advantage ages(GIII). For the study of the parallel processing pathways (magnocellular e parvocellular) we can see bigger contrast sensitivity to decrement than to increment of light. It was not possible determine the real contribution of these pathways to the contrast sensitivity function. Conclusion We evaluated in a successful way the spatial and temporal contrast sensitivity to all age range and so we could access the development of this function between the ages from 6 to 57 years old. Normatives values to this function were established for non parametric methodology. The study of the contribution of the parvocellular and magnocellular pathways is not conclusive, but the results showed a bigger sensibility to decrement than to increment of light that was similar to the literature
35

Impacto da catarata congênita na sensibilidade ao contraste espacial de luminância em crianças / Impact of congenital cataract in spatial contrast sensitivity to luminance in children

Martins, Cristiane Maria Gomes 14 December 2012 (has links)
A opacificação do cristalino presente ao nascimento ou nos primeiros meses de vida é denominada de Catarata Congênita (CC). As primeiras semanas de vida são importantes no desenvolvimento visual, já que há diferença significativa no desempenho visual de crianças que passaram pela cirurgia até seis semanas de vida (com melhor desempenho visual) em relação às crianças que realizaram a cirurgia após seis semanas de vida. Crianças que tiveram privação visual durante a primeira infância por catarata bilateral apresentam redução da visão espacial. O objetivo deste trabalho foi verificar o impacto na Função de Sensibilidade ao Contraste (FSC) em crianças de tratamento cirúrgico de Catarata Congênita, durante a fase de desenvolvimento visual. Foram avaliados três grupos: 11 crianças do grupo controle (média idade =6,83; DP=1,38), 9 crianças do grupo CC (média idade =6,87; DP=2,03) e 15 indivíduos adultos (média idade =27,63; DP=4,16). Foi utilizado o software Metropsis para avaliação da sensibilidade ao contraste de luminância de grade senoidal nas frequências espaciais de 0,2 cpg; 0,5 cpg; 1,0 cpg; 2,0 cpg; 4,2 cpg e 8,9 cpg e luminância média de 34,4 cd/m². Houve redução em toda a curva de sensibilidade ao contraste (SC) do grupo CC quando comparado ao grupo controle e não houve relação entre o tempo de privação e a redução da SC / The opacification of the lens present at birth is called Congenital Cataract (CC). The first weeks of life are important in visual development since there is not any significant difference in visual performance of children who had surgery within six weeks of life (with better visual performance) compared with children who underwent surgery after this period. Children who have visual deprivation during infancy due to bilateral cataracts have reduced spatial vision. The aim of this study was to assess the impact on Contrast Sensitivity Function (CSF) in children with Congenital Cataract surgery during the visual development age range. We evaluated three groups: 11 control children (mean age = 6.83, SD = 1.38), 9 children in the CC group (mean age = 6.87, SD = 2.03) and 15 adults (mean age = 27.63, SD = 4.16). Metropsis software was used to evaluate sensitivity to luminance contrast of the sinusoidal grating spatial frequencies of 0.2 cpd, 0.5 cpd, 1.0 cpd, 2.0 cpd, 4.2 cpd and 8.9 cpd with an average luminance of 34.4 cd / m². There was a reduction in the contrast sensitivity function (CSF) of the CC group compared to the control group and there was no correlation between the duration of deprivation and the impairment in the SC
36

Sur la convergence de certaines fonctionnelles de semimartingales discrétisées.

Diop, Assane 15 July 2009 (has links) (PDF)
L'étude de la p-variation d'un processus en probabilité n'est pas nouvelle.<br>Elle est en effet initiée par des auteurs parmi lesquels, on peut citer Lévy (1940), Blumenthal et Getoor (1960, 1961), Monroe (1972), Bretagnolle (1972) et Lépingle (1976). <br>Elle a connue un engouement ces dernières années en relation avec leur utilité révélée dans l'estimation de la volatilité et les tests de présence de sauts en mathématiques financières.<br>Dans cette thèse, nous généralisons certains résultats obtenus dans ce domaine avec des fonctions test qui dépendent de l'aléa, du temps et du l'espace.<br>Nous prouvons la convergence des processus étudiés et sous certaines conditionsnous donnons le théorème central limite associé.<br>Les résultats obtenus peuvent servir également en statistique des processus concernant la convergence des fonctions de contrastes.
37

Accélération d'ions par interaction laser-matière en régime de ultra haut contraste laser

Lévy, Anna 26 September 2008 (has links) (PDF)
Grâce au développement récent des lasers de puissance, le domaine de l'interaction laser-matière a beaucoup évolué, ouvrant depuis quelques années, entre autres, la possibilité de générer des faisceaux d'ions à des énergies de plusieurs MeV. Soumise à de très fortes intensités laser (> 1018 W/cm2), une cible solide est rapidement transformée en plasma. Une fraction de sa population électronique est accélérée à des vitesses relativistes et à l'origine de la génération d'ions à des énergies très élevées. Les faisceaux de particules ainsi produits affichent des caractéristiques particulièrement intéressantes pour différentes applications (diagnostics de plasmas denses, fusion inertielle, protonthérapie...). Cependant, malgré la montée en puissance des installations laser, pour nombre d'entre elles, les énergies atteintes restent aujourd'hui insuffisantes, suscitant un important effort de recherche visant à optimiser les processus d'accélération. En se plaçant dans un régime d'interaction de ultra-haut contraste, nous avons étudié l'influence de l'épaisseur de la cible sur l'accélération des ions et dégager l'intérêt de l'interaction avec des feuilles minces. Au-delà d'un accroissement de l'énergie et du nombre d'ions accélérés par réduction de l'épaisseur de la cible, nous avons mis en évidence les caractéristiques de chaque étape de l'interaction. De plus, en tirant parti de ces conditions optimales d'interaction, nous avons étudié l'influence d'un gradient ionique en face arrière de la cible sur l'accélération des ions, conditions dans lesquelles intervient un mécanisme fin de déferlement ionique.
38

Mécanismes d'interaction cellules-microbulles et ultrasons

Tran, Truong-An Bouakaz, Ayache. Le Guennec, Jean-Yves January 2008 (has links) (PDF)
Thèse de doctorat : Sciences de la vie et de la santé : Tours : 2008. / Titre provenant de l'écran-titre.
39

Nefropatia induzida por contraste e uso concomitante de medicamentos em tomografia computadorizada

Proença, Maria Conceição da Costa January 2011 (has links)
Made available in DSpace on 2013-08-07T19:03:53Z (GMT). No. of bitstreams: 1 000431010-Texto+Completo-0.pdf: 774075 bytes, checksum: c668dd399fc416556a5e23bbbdd91c8d (MD5) Previous issue date: 2011 / Introduction: Contrast-induced nephropathy is a widely used expression referring to a decrease in renal function after contrast administration. It has been characterized as an absolute increase in serum creatinine concentration of at least 0. 5 mg/dL or an of at least 25% increase, from baseline, 48 to 72 hours after intravenous contrast infusion, in the absence of another cause.Objective: To evaluate the association between contrast-induced nephropathy and the concomitant use of drugs or risk factors, in patients undergoing computerized tomography.Materials and methods: A cohort of 400 patients undergoing computerized tomography with iodine contrast. Evaluated variables were: gender, age, co-morbidities (diabetes, hypertension, congestive heart failure, stroke, obesity and renal failure), use of medication (metformin, acetilsalysilic acid, angiotensin-converting enzyme inhibitors, nonsteroidal anti-inflammatory, betablockers) and use of preventive measures. Serum creatinine was measured before, and 48 hours after contrast infusion. Current definitions were used throughout to characterize contrast-induced nephropathy occurrence. Risk factors were evaluated by a multivariate linear regression model.Results: Contrast-induced nephropathy incidence was 20. 6% (28/136) in patient using drugs and 12. 9% (34/264) in patient not using (p=0. 061). It was 19. 9% and 12. 9% (p=0. 091), respectively, by the percent increase criterion. Yet, by the absolute creatinine level increase, the incidence was 8. 8% and 1. 1% (p≤0. 001), respectively. Factors significantly associated with increased post-infusion creatinine levels were: male gender, old age, obesity, congestive heart failure, diabetes, decreased renal function, hypertension, no preventive measures, acetilsalysilic acid, angiotensinconverting enzyme inhibitors and betablockers use. Presence of congestive heart failure, reduced kidney function and diabetes remained positively associated in a multivariate regression model, whereas use of preventive measures and metformin were negatively associated.Conclusion: Incidence of contrast-induced nephropathy was higher in patients with previous diabetes, kidney or heart disease. Preventive measures and use of metformin may protective against it. / Introdução: O termo nefropatia induzida por contraste é amplamente utilizado para se referir a uma redução da função renal após administração de contraste radiológico. É definida pelo aumento absoluto na concentração de creatinina sérica de, pelo menos, 0,5 mg/dL ou por aumento relativo de, no mínimo, 25% do valor de base em 48 a 72 horas após a infusão, na ausência de causa alternativa.Objetivo: Avaliar a associação entre nefropatia induzida por contraste e o uso concomitante de medicamentos e/ou fatores de risco, em pacientes submetidos a Tomografia Computadorizada.Materiais e métodos: Coorte com 400 pacientes que realizaram exame tomográfico com contraste iodado. As variáveis analisadas foram: sexo, idade, diabetes mellitus, hipertensão arterial sistêmica, insuficiência cardíaca congestiva, acidente vascular encefálico, obesidade, perda de função renal, medicamentos em uso (metformina, ácido acetilsalicílico, inibidores da enzima conversora da angiotensina, anti-inflamatórios não esteróides, betabloqueadores) e uso de medidas preventivas. Dosou-se creatinina sérica antes e 48 horas após o exame para avaliar a presença de nefropatia do contraste. A presença de fatores de risco foi avaliada em pacientes que desenvolveram ou não nefropatia.Resultados: A incidência de nefropatia induzida por contraste, usando ambos os critérios, foi de 20,6% (28/136) em pacientes que utilizaram medicação e de 12,9% (34/264) nos que não utilizaram (p=0,061). Por aumento percentual, a incidência foi de 19,9% e de 12,9%, respectivamente (p=0,091), e, por aumento absoluto, foi de 8,8% e 1,1%, respectivamente (p<0,001). Na análise bivariada, foram significativamente associados a creatinina 48 horas após o exame: sexo masculino, idosos, obesos, pacientes com insuficiência cardíaca congestiva, diabetes, insuficiência renal, hipertensão, sem uso de medidas preventivas, acido acetilsalicílico, inibidores da enzima conversora da angiotensina e betabloqueador. Em modelo multivariado, permaneceram positivamente associados: Insuficiência renal, insuficiência cardíaca e diabetes. Medidas preventivas e uso de metformina foram negativamente associados.Conclusão: A incidência de nefropatia do contraste foi maior em pacientes com função renal e cardíaca previamente comprometida ou em portadores de diabetes mellitus. Medidas preventivas e o uso prévio de metformina foram protetores.
40

Uso de fluoresceína sódica em tumores da base de crânio: um estudo experimental introdutório com análise quantitativa digital de contraste tumoral

Silva, Carlos Eduardo da January 2010 (has links)
Made available in DSpace on 2013-08-07T19:04:14Z (GMT). No. of bitstreams: 1 000429857-Texto+Completo-0.pdf: 2540370 bytes, checksum: 378be904793c28ab99288056e50d378f (MD5) Previous issue date: 2010 / Objective: The authors present the first study with the use of sodium fluorescein (SF) to enhance skull base tumors and performed a quantitative digital analysis of the tumors enhancement. The study intends to observe the grade of tumor enhancement by SF. Methods: A prospective experimental within-subjects study design was performed including six patients with skull base lesions. Digital pictures were obtained before and after the SF systemic injection, using the same light-source of the microsurgical field. The pictures were analyzed by software, which calculated the wavelength of the sodium fluorescein pre and post injection. Results: The group of tumors was composed as it follows: 1 vestibular schwannoma, 3 meningiomas, 1 craniopharyngioma and 1 pituitary adenoma. The SF enhancement in all tumors was strongly positive. The digital analysis of the pictures, considering the SF wavelength pre and post injection, presented p=0. 028 (Wilcoxon T test).Conclusions: The enhancement of the tumors by SF was consistent and evident. The introductory results suggest the possibility of using SF as an adjuvant tool for the skull base surgery. Further studies should test the clinical application of the SF in skull base tumors. / Objetivo: Os autores apresentam o primeiro estudo com o uso de Fluoresceína Sódica (FS) para contrastar tumores da base do crânio e realizam uma análise quantitativa digital do contraste tumoral. O estudo tem por objetivo observar o grau de contraste tumoral pela FS.Métodos: Foi realizado um estudo experimental prospectivo com controle intragrupo, incluindo seis pacientes com lesões da base do crânio. Fotografias digitais foram realizadas antes e após a administração sistêmica de FS, utilizando a mesma fonte de iluminação do campo microcirúrgico. As fotografias pré e pós injeção de FS foram analisadas por um software, o qual calculou o comprimento de onda da FS nas respectivas imagens. Resultados: O grupo de tumores foi constituído por: 1 schwanoma vestibular, 3 meningeomas, 1 craniofaringeoma e 1 adenoma de hipófise. O contraste dos tumores pela FS foi fortemente positivo. A análise digital das fotografias, considerando os comprimentos de onda pré e pós injeção de FS, apresentou p=0,028 (Teste T de Wilcoxon).Conclusões: O contraste dos tumores pela FS foi consistente. Os resultados introdutórios sugerem a possibilidade de uso da FS como uma ferramenta adjuvante para a cirurgia da base de crânio. Estudos complementares são necessários para definir aplicação clínica da FS em tumores da base do crânio.

Page generated in 0.0537 seconds