• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 7
  • 2
  • Tagged with
  • 9
  • 9
  • 9
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Hybrid powertrains analysis for ship propulsion using energy storage. / Análise de alimentação híbrida para propulsão de navios usando sistemas de armazenamento de energia.

Vieira, Giovani Giulio Tristão Thibes 05 September 2018 (has links)
The ship emission already occupy the eighth position in the world biggest emitters ranking. This happens because the ship operations have a huge demand variation therefore in order to reduce the ship emissions is required an efficient operation of the generators. This work aims at integrating advanced storage systems into the operation of diesel generators. The variation of the operation point has a direct interference on the emissions and on the diesel consumption, this variation is allowed through the frequency and voltage control. The use of lithium batteries for various operation points of the generators is analyzed. The use of an energy storage system allowed the operation of the generators in a better operation point therefore there was a reduction in diesel consumption and in CO2 emissions when the diesel generators. The main result of this work could also shed light in the operation of isolated power systems equipped with advanced storage systems and diesel generators. / As emissões dos navios já ocupam a oitava posição entre os países com maior emissão no mundo. Isso pode ser explicado pelo fato de que as operações dos navios têm uma grande variação de demanda de potência, com isso a operação inteligente dos geradores a diesel é fundamental para a redução das emissões. A abordagem desenvolvida nesse trabalho integra o uso de sistemas de armazenamento avançados na operação dos geradores a diesel. A variação do ponto de operação dos geradores a diesel interfere diretamente no consumo e nas emissões, essa variação só é possível por meio do controle de frequência e tensão providos pelo sistema de armazenamento de energia. Nesse trabalho foram analisados o uso de baterias de lítio para diferentes pontos de operação do gerador a diesel. O uso das baterias possibilitou a operação dos geradores num melhor ponto de carga com isso houve uma redução das emissões e do consumo de combustível. Os resultados encontrados nesse trabalho podem ser extrapolados qualitativamente para outros sistemas de potência offshore, como plataformas de petróleo e de perfuração, que operem com sistemas de baterias avançadas e geradores a diesel.
2

Hybrid powertrains analysis for ship propulsion using energy storage. / Análise de alimentação híbrida para propulsão de navios usando sistemas de armazenamento de energia.

Giovani Giulio Tristão Thibes Vieira 05 September 2018 (has links)
The ship emission already occupy the eighth position in the world biggest emitters ranking. This happens because the ship operations have a huge demand variation therefore in order to reduce the ship emissions is required an efficient operation of the generators. This work aims at integrating advanced storage systems into the operation of diesel generators. The variation of the operation point has a direct interference on the emissions and on the diesel consumption, this variation is allowed through the frequency and voltage control. The use of lithium batteries for various operation points of the generators is analyzed. The use of an energy storage system allowed the operation of the generators in a better operation point therefore there was a reduction in diesel consumption and in CO2 emissions when the diesel generators. The main result of this work could also shed light in the operation of isolated power systems equipped with advanced storage systems and diesel generators. / As emissões dos navios já ocupam a oitava posição entre os países com maior emissão no mundo. Isso pode ser explicado pelo fato de que as operações dos navios têm uma grande variação de demanda de potência, com isso a operação inteligente dos geradores a diesel é fundamental para a redução das emissões. A abordagem desenvolvida nesse trabalho integra o uso de sistemas de armazenamento avançados na operação dos geradores a diesel. A variação do ponto de operação dos geradores a diesel interfere diretamente no consumo e nas emissões, essa variação só é possível por meio do controle de frequência e tensão providos pelo sistema de armazenamento de energia. Nesse trabalho foram analisados o uso de baterias de lítio para diferentes pontos de operação do gerador a diesel. O uso das baterias possibilitou a operação dos geradores num melhor ponto de carga com isso houve uma redução das emissões e do consumo de combustível. Os resultados encontrados nesse trabalho podem ser extrapolados qualitativamente para outros sistemas de potência offshore, como plataformas de petróleo e de perfuração, que operem com sistemas de baterias avançadas e geradores a diesel.
3

Aplicação do software scicoslab para análise do controle automático de geração de sistemas elétricos de potência / Application of ScicosLab software for analysis of automatic generation control of electric power systems

Oda, George 22 June 2012 (has links)
The purpose of this paper is to show that the software ScicosLab can be used as an interesting and effective computational tool to analyze the automatic generation control of electric power systems. Firstly it is presented the software and, afterwards, the concepts and definitions of rotational movements in order to develop mathematical models for the generators equipped with steam turbines or hydraulic turbines and speed governors, and for their electrical loads. For the studies it is used a system comprised by two distinct interconnected areas where a load increase in one area is simulated without/with the tieline, ignoring, and then considering the primary and supplementary controls. Finally, it is analyzed a more realistic system with three distinct areas extracted from the Brazilian power system. The computational results show graphically the variations of the two main quantities of interest: the frequency of each area of the system and the tieline power. These quantities allow the evaluation of the system behavior after a disturbance that affects the generation-load balance. Within the above context, it is verified that the ScicosLab computer package effectively models and simulates the load-frequency control of power systems, qualifying, therefore, as an excellent alternative to replace any similar program which requires license payment. / A proposta deste trabalho é mostrar que o software ScicosLab pode ser utilizado como uma ferramenta computacional, interessante e eficaz, para analisar o controle automático de geração de sistemas elétricos de potência. Inicialmente é apresentado o software e, em seguida, os conceitos de movimentos rotativos que permitem desenvolver os modelos matemáticos para os geradores equipados com turbinas a vapor ou hidráulica e reguladores de velocidade, e para suas cargas elétricas. Para possibilitar os estudos é utilizado um sistema constituído por duas áreas distintas interligadas, onde é simulado um aumento de carga em uma destas áreas, sem e com a linha de interligação, desconsiderando e, em seguida, considerando os controles primário e suplementar. Finalmente, analisa-se um sistema mais realístico com três áreas distintas extraído do sistema elétrico brasileiro. Os resultados computacionais mostram graficamente as variações das duas principais grandezas de interesse: a frequência de cada área do sistema e a potência da linha de interligação. Estas grandezas permitem avaliar o comportamento do sistema após uma perturbação que afeta o balanço geração-carga. Considerando o exposto acima, constata-se que o pacote computacional ScicosLab modela e simula eficazmente o controle carga-frequência de sistemas elétricos de potência, qualificando-se, portanto, como uma excelente alternativa para substituir qualquer programa similar que exige pagamento de licença. / Mestre em Ciências
4

Adaptações autonômicas e cardiovasculares em atletas de alto rendimento: influência da modalidade e periodização do treinamento físico / Autonomic and cardiovascular adaptations in high performance athletes: influence of sport modality and physical training periodization

Azevedo, Luciene Ferreira 11 August 2011 (has links)
INTRODUÇÃO: O treinamento físico provoca adaptações cardiovasculares, sendo que maiores adaptações estruturais cardíacas são observadas em atletas de elite, que realizam treinamento físico de alta intensidade com o objetivo de aumento no rendimento. Além disto, atletas apresentam diminuição da frequência cardíaca de repouso, embora os mecanismos que explicam a bradicardia em atletas ainda são controversos. O nível das adaptações pode variar e fatores como o tipo de modalidade esportiva, tempo e nível de treinamento físico podem contribuir para tal variação. Desta forma, o objetivo deste estudo foi investigar a influência de modalidades esportivas (ciclismo, corrida de longa distância e remo) e da periodização do treinamento físico nas adaptações estruturais e funcionais, autonômicas e não autonômicas cardíacas e vasculares em atletas de elite no repouso, na inclinação ortostática e nas 24 horas. MÉTODOS: Neste estudo experimental longitudinal prospectivo foram avaliados 13 ciclistas, 13 corredores e 11 remadores de elite, saudáveis (entre 20 e 36 anos; masculino), engajados em treinamento físico competitivo, em 2 períodos de treinamento: período básico-PB e período competitivo-PC. Avaliação da capacidade funcional máxima foi feita por teste cardiorrespiratório. Adaptações estruturais cardíacas foram avaliadas por meio do ecocardiograma bidimensional com doppler. Frequência cardíaca intrínseca foi estudada por meio do duplo bloqueio farmacológico (atropina 0,04 mg/kg e esmolol 500 g/kg, i.v.). Frequência cardíaca e pressão arterial foram registradas continuamente no repouso e no teste de inclinação ortostática por meio de ECG e monitor de pressão arterial, respectivamente (500Hz). A variabilidade da frequência cardíaca e pressão arterial foram analisadas pelo método auto-regressivo. Frequência cardíaca e pressão arterial de 24 horas foram aquisitadas pelo Holter e Mapa, respectivamente. Avaliação da sensibilidade barorreflexa espontânea foi calculada pelo método da sequência. Os dados foram apresentados como mediana e variação interquartil. RESULTADOS: Remadores apresentaram maior VO2max que os corredores no PC (p<0,04). Ciclistas e remadores apresentaram maior VO2max no PC comparado ao PB (p<0,05). Corredores apresentaram maiores diâmetros diastólicos do ventrículo esquerdo que ciclistas (p<0,06) e remadores (p<0,01) no PB. Corredores e ciclistas apresentaram maiores diâmetros diastólicos do ventrículo esquerdo que remadores (p<0,004) no PC. Corredores apresentaram maiores índices de massa do ventrículo esquerdo que ciclistas (p<0,04) no PB e ciclistas maiores que remadores (p<0,03) no PC. Ciclistas foram os únicos atletas que apresentaram a reversão do remodelamento cardíaco no PB (p<0,04). No repouso, corredores mostraram menor frequência cardíaca que ciclistas no PC ciclistas = 50(45/55), corredores = 44(43/47), remadores = 44(43/53)bpm, p<0,03]. Corredores e remadores mostraram maior efeito vagal [ciclistas = 41(36/46), corredores = 55(48/59), remadores = 50(42/66)bpm, p=0,03] e maior frequência cardíaca intrínseca ciclistas = 84(82/87), corredores = 92(87/94), remadores = 96(85/101)bpm, p=0,03] que ciclistas no PC. Remadores tinham maior frequência cardíaca intrínseca que ciclistas no PB ciclistas = 88(86/92), corredores = 91(82/99), remadores = 95(90/101)bpm, p=0,03]. PC comparado ao PB diminuiu o efeito vagal 41(36/46) vs. 48(43/51)bpm, p<0,05] e frequência cardíaca intrínseca 84(82/87) vs. 88(86/92), p<0,05] dos ciclistas. No teste de inclinação, corredores mostraram menor aumento da frequência cardíaca que ciclistas no PB ciclistas = 64(49/73), corredores = 46(43/55), remadores = 53(42/77)%, p<0,05]. Nem a modalidade ou período de treinamento físico influenciaram os índices de variabilidade da frequência cardíaca no repouso ou na inclinação ortostática. A modalidade esportiva e o período de treinamento físico influenciaram a pressão arterial e sua variabilidade, no repouso e na inclinação ortostática. Remadores apresentaram menor sensibilidade barorreflexa espontânea que corredores no PC (p=0,03). Tanto a modalidade quanto o período de treinamento físico influenciaram a resposta da frequência cardíaca de 24 horas, sua variabilidade e a resposta da pressão arterial de 24 horas. CONCLUSÃO: Tanto a modalidade esportiva quanto o período de treinamento físico influenciaram nas adaptações estruturais cardíacas, intrínsecas e autonômicas cardíacas e vasculares. Entretanto a modalidade esportiva parece influenciar mais expressivamente essas adaptações / INTRODUCTION: Physical exercise training provokes cardiovascular adaptations and the highest structural cardiac adaptations are observed in elite athletes who perform high intensity training with the objective of increasing their physical performance. Besides, athlete shows decrease on resting heart rate. However, the mechanisms that explain the bradycardia in athletes are still controversial. The level of these adaptations may vary and some factors as the type of sport modality, time and level of physical training can contribute to such different responses. Thus, the aim of this study was to investigate the influence of sport modalities (cycling, long distane runner and rower) and physical training periodization on cardiac structural and functional, cardiac autonomic and non-autonomic and vascular adaptations in elite athletes at rest, tilt table test and within 24 hours. METHODS: In this prospective longitudinal experimental study, 13 cyclists, 13 runners and 11 rowers, healthy (20 to 36 years old; male), engaged in competitive training were evaluated in 2 periods of training: basic period BP and competitive period -CP. Maximal functional capacity was evaluated by cardiopulmonary test. Cardiac structural adaptations were evaluated by two-dimensional echocardiography with doppler. Intrinsic heart rate was studied by means of double pharmacological blockade (atropine 0.04 mg/kg and esmolol 500 g/kg, iv.). Heart rate and blood pressure were recorded continuously at rest and tilt table test by means of ECG and arterial blood pressure monitor, respectively (500Hz). The heart rate and blood pressure variabilities were analyzed by autoregressive method. Heart rate and blood pressure within 24 hours were recorded using Holter and blood pressure ambulatory monitor, respectivamente. Spontaneous baroreflex sensitivity was calculated using the sequence method. The data were presented as median and interquartile range. RESULTS: Rowers showed higher VO2max than runners at CP (p<0.04). Cyclists and rowers showed higher VO2max at CP compared to BP (p<0.05). Runners presented higher left ventricular diastolic diameters than cyclists (p<0.06) and rowers (p<0.01) at BP. Runners and cyclists presented higher left ventricular diastolic diameters than rowers (p<0.004) at CP. Runners showed higher left ventricular mass index than cyclistas (p<0.04) at BP and cyclists higher than rowers (p<0.03) at CP. Cyclists were the only athletes who had a reversal of cardiac remodeling at BP (p<0.04). At rest, runners showed lower heart rate than cyclists at CP cyclists = 50(45/55), runners = 44(43/47), rowers = 44(43/53)bpm, p<0.03]. Runners and rowers showed higher vagal effect [cyclists = 41(36/46), runners = 55(48/59), rowers = 50(42/66)bpm, p=0.03] and higher intrinsic heart rate cyclists = 84(82/87), runners = 92(87/94), rowers = 96(85/101)bpm, p=0,03] than cyclists at CP. Rowers had higher intrinsic herat rate than cyclists at BP cyclists = 88(86/92), runners = 91(82/99), rowers = 95(90/101)bpm, p=0.03]. CP compared with BP decreased the vagal effect 41(36/46) vs. 48(43/51)bpm, p<0.05] and intrinsic heart rate 84(82/87) vs. 88(86/92), p<0.05] of cyclists. At tilt table test, runners showed smaller increase in heart rate than cyclists at BP cyclists = 64(49/73), runners = 46(43/55), rowers = 53(42/77)%, p<0.05]. Neither the sport modality or the training period influenced the indices of heart rate variability at rest and tilt test. The sport modality and the training period influenced the blood pressure and its variability at rest and tilt test. Rowers showed lower spontaneous baroreflex sensitivity than runners at CP (p=0.03). Both the sport modality and the training period influenced the heart rate response in 24 hours, its variability and blood pressure response in 24 hours. CONCLUSION: Both Sport modality and physical training period influenced the cardiac structural, intrinsic and autonomic adaptations as well the vascular adaptations. However, the sport modality seems to influence more significantly these adaptations
5

Inclusão de energia eólica em sistemas elétricos e controle de frequência utilizando lógica Fuzzy.

MACÊDO, Ana Vitória de Almeida. 24 August 2018 (has links)
Submitted by Maria Medeiros (maria.dilva1@ufcg.edu.br) on 2018-08-24T14:29:39Z No. of bitstreams: 1 ANA VITÓRIA DE ALMEIDA MACÊDO - TESE (PPgEE) 2017.pdf: 3449345 bytes, checksum: ff78e54595b43261343d5050a8dc3e50 (MD5) / Made available in DSpace on 2018-08-24T14:29:39Z (GMT). No. of bitstreams: 1 ANA VITÓRIA DE ALMEIDA MACÊDO - TESE (PPgEE) 2017.pdf: 3449345 bytes, checksum: ff78e54595b43261343d5050a8dc3e50 (MD5) Previous issue date: 2017-03-29 / CNPq / Um controle para auxílio do controle de frequência é projetado utilizando um método baseado em lógica fuzzy e no controle do ângulo de passo de turbinas eólicas de velocidade variável. O controle visa que as turbinas eólicas operem abaixo do seu valor nominal, estando sempre prontas para aumentar sua geração no caso de evento na rede elétrica, contribuindo para o controle de frequência. Com os esforços para converter tanta energia quanto seja possível com o vento disponível, a potência desperdiçada pela maioria dos controles estudados para elaboração desta tese vale a pena em relação aos benefícios do controle de frequência em sistemas com grande penetração das usinas eólicas, proporcionando a participação da energia eólica nos serviços ancilares. Ressaltando que a introdução de qualquer nova tecnologia de geração no sistema deve ser feita de modo que seja compatível com os princípios operacionais do sistema existente. O controle fuzzy de potência foi desenvolvido no Matlab®/Simulink e permite o bom funcionamento da turbina eólica utilizando uma metodologia alternativa aos controles clássicos. Com isto foi desenvolvido o controle de frequência também baseado em lógica fuzzy. Como grande vantagem do controle fuzzy destaca-se sua fácil adaptação a outros modelos de turbina que utilizem o controle de pitch (turbinas eólicas de velocidade variável), uma vez que o algoritmo é o mesmo, havendo a necessidade apenas de fazer testes para adaptação das faixas de operação do controle. / A control to support the frequency control is designed using a method based on fuzzy logic and pitch angle control in variable speed wind turbines. The control aims that some wind turbines operate below their rated value (derated or deloaded), being always ready to increase their generation in case of some event in the power grid, contributing to the frequency control. With efforts to convert as much energy as possible with the available wind, the power wasted by most controls studied in this work worth of the benefits of frequency control in systems with high power plants penetration, providing wind power to participate on ancillary services. Recalling that the introduction of any new generation technology into the system must be made in a way that is compatible with the operating principles of the existing system. The fuzzy control developed in Matlab®/Simulink for power control enables a suitable operation of the wind turbine using an alternative methodology to the classic controls, it was developed the frequency control also based on fuzzy logic. The fuzzy control great advantage highlight is its easy adaptation to other turbine design which use pitch control (variable speed wind turbines), since the algorithm is the same, just by doing tests for adjustment of the control operation ranges.
6

Ajustes da variabilidade da frequência cardíaca em repouso e durante o exercício em indivíduos com asma controlada

Araújo, Adriana Sanches Garcia de 29 August 2014 (has links)
Made available in DSpace on 2016-06-02T20:18:24Z (GMT). No. of bitstreams: 1 6321.pdf: 1608143 bytes, checksum: 79020037f93ef260d48c286f33c9f952 (MD5) Previous issue date: 2014-08-29 / Universidade Federal de Minas Gerais / Asthma is a chronic disease, with periods of exacerbation and worsening of airflow obstruction and may be triggered by various stimuli, including exercise, and is associated with dysfunction of the autonomic nervous system (ANS). In this context, two studies were conducted to assess adjustments of ANS in asthmatic volunteers in different situations. The first study was entitled: Increased sympathetic modulation and decreased response of the heart rate variability response in controlled asthma , was designed to evaluate the adjustments of indices of autonomic modulation of heart rate (HR) at rest in supine and seated positions and during the respiratory sinus arrhythmia maneuver (M-RSA). The assessment of 12 asthmatic volunteers included pulmonary function tests and measures of heart rate variability (HRV). The results suggest that in asthma appears to be an association of airflow obstruction with reduced total variability, and in addition, to postural change seems to be reduced adjustment of the sympathetic nervous system in asthmatic women. The second study entitled: Airway responsiveness at exercise recovery and adjustments of heart rate variability at rest and exercise in controlled asthma , evaluated the adjustments of cardiac autonomic modulation during exercise its association with the exercise induced bronchoconstriction. Sixteen asthmatics volunteers underwent constant speed exercise test, forced vital capacity maneuver before and after exercise testing and register of HR and R-R intervals. With this second study, it can conclude that in asthmatics, even with controlled disease, injury presents postural and autonomic adjustments during the year and reduced complexity of dynamical systems of HRV during exercise. / A asma é uma doença crônica, com períodos de exacerbação e piora da obstrução ao fluxo aéreo, podendo ser desencadeada por vários estímulos, incluindo o exercício, e está associada a disfunções do sistema nervoso autonômico (SNA). Nesse contexto, foram realizados dois estudos para avaliação dos ajustes do SNA em voluntários asmáticos, em diferentes situações. O primeiro estudo intitulado: Elevada modulação simpática e atenuada resposta da variabilidade da frequência cardíaca na asma controlada , teve como objetivo avaliar os ajustes dos índices de modulação autonômica da frequência cardíaca (FC) em repouso, na manobra de mudança postural e durante a manobra de acentuação da arritmia sinusal respiratória. A avaliação de 12 voluntárias asmáticas, incluiu prova de função pulmonar e medidas da variabilidade da frequência cardíaca (VFC) nas diferentes posições e durante a manobra de acentuação da arritmia sinusal respiratória. Os resultados sugerem que na asma parece haver associação da obstrução ao fluxo aéreo com reduzida variabilidade total, e além disso, frente à mudança postural parece haver reduzido ajuste do sistema nervoso simpático em mulheres asmáticas. Diante destes resultados, objetivamos avaliar a VFC também durante o exercício em voluntários asmáticos. Sendo assim, o segundo estudo intitulado: Responsividade das vias aéreas na recuperação do exercício e os ajustes da variabilidade da frequência cardíaca em repouso e durante o exercício em asmáticos controlados , avaliou os ajustes da modulação autonômica cardíaca durante o exercício e sua associação com a presença de broncoconstrição induzia pelo exercício (BIE). Dezesseis voluntários com asma foram submetidos a um teste de exercício de carga constante em esteira, manobras de capacidade vital forçada antes e após o teste de exercício e registro da FC e dos intervalos R-R. Com este segundo estudo, pode-se concluir que em asmáticos, mesmo com a doença controlada, há prejuízo nos ajustes autonômicos posturais e durante o exercício, bem como reduzida complexidade dos sistemas dinâmicos de VFC durante o exercício.
7

Avaliação cardiorrespiratória e efeitos da hidroterapia em mulheres com síndrome fibromiálgica

Zamunér, Antonio Roberto 27 February 2015 (has links)
Made available in DSpace on 2016-06-02T20:18:24Z (GMT). No. of bitstreams: 1 6628.pdf: 2096489 bytes, checksum: 10c86cad94537d1f0aa91db0ca9d0335 (MD5) Previous issue date: 2015-02-27 / Financiadora de Estudos e Projetos / Fibromyalgia syndrome (FMS) is a non-inflammatory chronic pain syndrome characterized by diffuse musculoskeletal pain. Advances have been made in underlying its etiology and pathophysiology and some evidence has suggested that autonomic dysfunction plays an important role in FMS. Thus, the present thesis consisted of three studies in order to elucidate unknown aspects regarding the autonomic cardiovascular control in women with FMS. The Study I, entitled "Respiratory sinus arrhythmia and its association with pain in women with fibromyalgia syndrome", aimed to evaluate the autonomic modulation of heart rate (HR) at rest and during the deep breathing test, as well as to evaluate possible associations between cardiac autonomic indices and the pain in women with FMS. The results suggest that women with FMS present compromised neurocardiac integrity, which is associated with the pain and the impact on quality of life. The Study II, entitled "Cardiovascular Control in women with fibromyalgia syndrome: the causal methods provide complementary information to traditional methods?", aimed to assess whether the baroreflex sensitivity assessed by the model-based causal closedloop approach based on spontaneous RR and systolic arterial pressure variabilities during supine and active standing in patients with FMS could provide complementary information to those obtained by traditional indices based on time and frequency domains. The model-based causal closed-loop method provided complementary information on the cardiovascular autonomic control, revealing reduced baroreflex sensitivity, a reduced strength of the baroreflex control as well as a blunted response to the orthostatic stimulus in FMS patients. The Study III, entitled "Effects of a hydrotherapy program on symbolic dynamics and complexity of heart rate variability and aerobic capacity in women with fibromyalgia syndrome", aimed to evaluate the effects of a hydrotherapy program on aerobic capacity and linear and non-linear dynamics of heart rate variability in women with FMS. A 16-week hydrotherapy program proved to be effective in improving symptoms, aerobic functional capacity and cardiac autonomic control in women with FMS. The improvement in non-linear dynamics of HR variability was associated with the improvement of pain and the impact of FMS on the quality of life. / A síndrome fibromiálgica (SFM) é uma síndrome dolorosa crônica não inflamatória, caracterizada por dores musculoesqueléticas difusas. Avanços têm sido realizados para o entendimento da sua etiologia e fisiopatologia e algumas evidências têm sugerido que a disfunção autonômica exerce importante papel na SFM. Assim, a tese foi composta por três estudos com o intuito de elucidar aspectos ainda desconhecidos sobre o controle autonômico cardiovascular em mulheres com SFM. O Estudo I, intitulado Arritmia sinusal respiratória e sua associação com a dor em mulheres com síndrome fibromiálgica , teve como objetivo avaliar a modulação autonômica da frequência cardíaca (FC) em repouso e durante a manobra de acentuação da arritmia sinusal respiratória, bem como avaliar possíveis associações entre os índices autonômicos e a dor em mulheres com SFM. Os resultados sugerem que mulheres com SFM apresentam comprometimento da integridade neurocárdica, a qual está associada à dor e ao impacto na qualidade de vida. O Estudo II, intitulado Controle cardiovascular em mulheres com síndrome fibromiálgica: os métodos causais fornecem informações complementares aos métodos tradicionais? . Esse estudo objetivou avaliar se a aplicação do método model-based causal closed-loop na quantificação da sensibilidade barorreflexa, nas posturas supina e ortostática em mulheres com SFM, fornece informações complementares àquelas proporcionadas pelos índices tradicionais baseados nos domínios do tempo e da frequência. O método model-based causal closed-loop permitiu obter informações complementares, extremamente relevantes, sobre o controle autonômico cardiovascular, revelando comprometimento da função barorreflexa em pacientes com SFM, em relação ao grupo saudável, em repouso e frente ao estímulo ortostático. O Estudo III, intitulado Efeitos de um programa de hidroterapia nas dinâmicas simbólicas e de complexidade da variabilidade da frequência cardíaca e na capacidade aeróbia em mulheres com síndrome fibromiálgica teve como objetivo verificar a influência da hidroterapia sobre as variáveis cardiorrespiratória e sua relação com a dor e com a qualidade de vida em mulheres com SFM. Um programa de hidroterapia de 16 semanas mostrou ser efetivo em melhorar os sintomas, a capacidade funcional aeróbia e o controle autonômico cardíaco em mulheres com SFM. A melhora na dinâmica não linear da variabilidade da FC se associou com a melhora da dor e do impacto da SFM na qualidade de vida.
8

Adaptações autonômicas e cardiovasculares em atletas de alto rendimento: influência da modalidade e periodização do treinamento físico / Autonomic and cardiovascular adaptations in high performance athletes: influence of sport modality and physical training periodization

Luciene Ferreira Azevedo 11 August 2011 (has links)
INTRODUÇÃO: O treinamento físico provoca adaptações cardiovasculares, sendo que maiores adaptações estruturais cardíacas são observadas em atletas de elite, que realizam treinamento físico de alta intensidade com o objetivo de aumento no rendimento. Além disto, atletas apresentam diminuição da frequência cardíaca de repouso, embora os mecanismos que explicam a bradicardia em atletas ainda são controversos. O nível das adaptações pode variar e fatores como o tipo de modalidade esportiva, tempo e nível de treinamento físico podem contribuir para tal variação. Desta forma, o objetivo deste estudo foi investigar a influência de modalidades esportivas (ciclismo, corrida de longa distância e remo) e da periodização do treinamento físico nas adaptações estruturais e funcionais, autonômicas e não autonômicas cardíacas e vasculares em atletas de elite no repouso, na inclinação ortostática e nas 24 horas. MÉTODOS: Neste estudo experimental longitudinal prospectivo foram avaliados 13 ciclistas, 13 corredores e 11 remadores de elite, saudáveis (entre 20 e 36 anos; masculino), engajados em treinamento físico competitivo, em 2 períodos de treinamento: período básico-PB e período competitivo-PC. Avaliação da capacidade funcional máxima foi feita por teste cardiorrespiratório. Adaptações estruturais cardíacas foram avaliadas por meio do ecocardiograma bidimensional com doppler. Frequência cardíaca intrínseca foi estudada por meio do duplo bloqueio farmacológico (atropina 0,04 mg/kg e esmolol 500 g/kg, i.v.). Frequência cardíaca e pressão arterial foram registradas continuamente no repouso e no teste de inclinação ortostática por meio de ECG e monitor de pressão arterial, respectivamente (500Hz). A variabilidade da frequência cardíaca e pressão arterial foram analisadas pelo método auto-regressivo. Frequência cardíaca e pressão arterial de 24 horas foram aquisitadas pelo Holter e Mapa, respectivamente. Avaliação da sensibilidade barorreflexa espontânea foi calculada pelo método da sequência. Os dados foram apresentados como mediana e variação interquartil. RESULTADOS: Remadores apresentaram maior VO2max que os corredores no PC (p<0,04). Ciclistas e remadores apresentaram maior VO2max no PC comparado ao PB (p<0,05). Corredores apresentaram maiores diâmetros diastólicos do ventrículo esquerdo que ciclistas (p<0,06) e remadores (p<0,01) no PB. Corredores e ciclistas apresentaram maiores diâmetros diastólicos do ventrículo esquerdo que remadores (p<0,004) no PC. Corredores apresentaram maiores índices de massa do ventrículo esquerdo que ciclistas (p<0,04) no PB e ciclistas maiores que remadores (p<0,03) no PC. Ciclistas foram os únicos atletas que apresentaram a reversão do remodelamento cardíaco no PB (p<0,04). No repouso, corredores mostraram menor frequência cardíaca que ciclistas no PC ciclistas = 50(45/55), corredores = 44(43/47), remadores = 44(43/53)bpm, p<0,03]. Corredores e remadores mostraram maior efeito vagal [ciclistas = 41(36/46), corredores = 55(48/59), remadores = 50(42/66)bpm, p=0,03] e maior frequência cardíaca intrínseca ciclistas = 84(82/87), corredores = 92(87/94), remadores = 96(85/101)bpm, p=0,03] que ciclistas no PC. Remadores tinham maior frequência cardíaca intrínseca que ciclistas no PB ciclistas = 88(86/92), corredores = 91(82/99), remadores = 95(90/101)bpm, p=0,03]. PC comparado ao PB diminuiu o efeito vagal 41(36/46) vs. 48(43/51)bpm, p<0,05] e frequência cardíaca intrínseca 84(82/87) vs. 88(86/92), p<0,05] dos ciclistas. No teste de inclinação, corredores mostraram menor aumento da frequência cardíaca que ciclistas no PB ciclistas = 64(49/73), corredores = 46(43/55), remadores = 53(42/77)%, p<0,05]. Nem a modalidade ou período de treinamento físico influenciaram os índices de variabilidade da frequência cardíaca no repouso ou na inclinação ortostática. A modalidade esportiva e o período de treinamento físico influenciaram a pressão arterial e sua variabilidade, no repouso e na inclinação ortostática. Remadores apresentaram menor sensibilidade barorreflexa espontânea que corredores no PC (p=0,03). Tanto a modalidade quanto o período de treinamento físico influenciaram a resposta da frequência cardíaca de 24 horas, sua variabilidade e a resposta da pressão arterial de 24 horas. CONCLUSÃO: Tanto a modalidade esportiva quanto o período de treinamento físico influenciaram nas adaptações estruturais cardíacas, intrínsecas e autonômicas cardíacas e vasculares. Entretanto a modalidade esportiva parece influenciar mais expressivamente essas adaptações / INTRODUCTION: Physical exercise training provokes cardiovascular adaptations and the highest structural cardiac adaptations are observed in elite athletes who perform high intensity training with the objective of increasing their physical performance. Besides, athlete shows decrease on resting heart rate. However, the mechanisms that explain the bradycardia in athletes are still controversial. The level of these adaptations may vary and some factors as the type of sport modality, time and level of physical training can contribute to such different responses. Thus, the aim of this study was to investigate the influence of sport modalities (cycling, long distane runner and rower) and physical training periodization on cardiac structural and functional, cardiac autonomic and non-autonomic and vascular adaptations in elite athletes at rest, tilt table test and within 24 hours. METHODS: In this prospective longitudinal experimental study, 13 cyclists, 13 runners and 11 rowers, healthy (20 to 36 years old; male), engaged in competitive training were evaluated in 2 periods of training: basic period BP and competitive period -CP. Maximal functional capacity was evaluated by cardiopulmonary test. Cardiac structural adaptations were evaluated by two-dimensional echocardiography with doppler. Intrinsic heart rate was studied by means of double pharmacological blockade (atropine 0.04 mg/kg and esmolol 500 g/kg, iv.). Heart rate and blood pressure were recorded continuously at rest and tilt table test by means of ECG and arterial blood pressure monitor, respectively (500Hz). The heart rate and blood pressure variabilities were analyzed by autoregressive method. Heart rate and blood pressure within 24 hours were recorded using Holter and blood pressure ambulatory monitor, respectivamente. Spontaneous baroreflex sensitivity was calculated using the sequence method. The data were presented as median and interquartile range. RESULTS: Rowers showed higher VO2max than runners at CP (p<0.04). Cyclists and rowers showed higher VO2max at CP compared to BP (p<0.05). Runners presented higher left ventricular diastolic diameters than cyclists (p<0.06) and rowers (p<0.01) at BP. Runners and cyclists presented higher left ventricular diastolic diameters than rowers (p<0.004) at CP. Runners showed higher left ventricular mass index than cyclistas (p<0.04) at BP and cyclists higher than rowers (p<0.03) at CP. Cyclists were the only athletes who had a reversal of cardiac remodeling at BP (p<0.04). At rest, runners showed lower heart rate than cyclists at CP cyclists = 50(45/55), runners = 44(43/47), rowers = 44(43/53)bpm, p<0.03]. Runners and rowers showed higher vagal effect [cyclists = 41(36/46), runners = 55(48/59), rowers = 50(42/66)bpm, p=0.03] and higher intrinsic heart rate cyclists = 84(82/87), runners = 92(87/94), rowers = 96(85/101)bpm, p=0,03] than cyclists at CP. Rowers had higher intrinsic herat rate than cyclists at BP cyclists = 88(86/92), runners = 91(82/99), rowers = 95(90/101)bpm, p=0.03]. CP compared with BP decreased the vagal effect 41(36/46) vs. 48(43/51)bpm, p<0.05] and intrinsic heart rate 84(82/87) vs. 88(86/92), p<0.05] of cyclists. At tilt table test, runners showed smaller increase in heart rate than cyclists at BP cyclists = 64(49/73), runners = 46(43/55), rowers = 53(42/77)%, p<0.05]. Neither the sport modality or the training period influenced the indices of heart rate variability at rest and tilt test. The sport modality and the training period influenced the blood pressure and its variability at rest and tilt test. Rowers showed lower spontaneous baroreflex sensitivity than runners at CP (p=0.03). Both the sport modality and the training period influenced the heart rate response in 24 hours, its variability and blood pressure response in 24 hours. CONCLUSION: Both Sport modality and physical training period influenced the cardiac structural, intrinsic and autonomic adaptations as well the vascular adaptations. However, the sport modality seems to influence more significantly these adaptations
9

Um novo modelo para representação da regulação primária e secundária de frequência no problema de fluxo de potência e fluxo de potência ótimo

La Gatta, Paula Oliveira 05 March 2012 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-07-01T14:29:29Z No. of bitstreams: 1 paulaoliveiralagatta.pdf: 1917786 bytes, checksum: 627585584595873c205fcbcf5c79980f (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-07-13T16:01:23Z (GMT) No. of bitstreams: 1 paulaoliveiralagatta.pdf: 1917786 bytes, checksum: 627585584595873c205fcbcf5c79980f (MD5) / Made available in DSpace on 2016-07-13T16:01:23Z (GMT). No. of bitstreams: 1 paulaoliveiralagatta.pdf: 1917786 bytes, checksum: 627585584595873c205fcbcf5c79980f (MD5) Previous issue date: 2012-03-05 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Neste trabalho são propostas duas formulações de importantes ferramentas para análise de redes em regime permanente, onde são consideradas equações que descrevem o comportamento do controle primário e secundário de frequência em sistemas elétricos de potência. A primeira proposta é baseada em uma formulação do problema de fluxo de potência convencional e a segunda uma formulação do fluxo de potência ótimo. A formulação de fluxo de potência proposta é desenvolvida a partir de uma metodologia genérica de representação de dispositivos de controle. Esta metodologia consiste em incorporar as equações que modelam dispositivos de controle ao problema básico de fluxo de potência em coordenadas polares, formando um sistema de equações de ordem (2nb+nc). O fluxo de potência desenvolvido é capaz de estimar os desvios de frequência do sistema devido a uma perturbação da carga. Por outro lado, o fluxo de potência ótimo proposto é capaz de identificar montantes e locais de corte carga, de forma a manter a frequência do sistema em uma faixa aceitável de operação. A formulação proposta de FPO consiste em incluir no problema equações de igualdade e desigualdade associadas com o controle primário de frequência e geração de potência ativa. Os desenvolvimentos propostos para o fluxo de potência convencional foram implementados no ambiente MatLab®. Para solução do fluxo de potência ótimo utilizou-se um pacote comercial de otimização, denominado LINGO®. A avaliação do fluxo de potência e fluxo de potência ótimo propostos é feita através do estudo de sistemas tutoriais e do sistema New England. A validação da análise de desvios de frequência é feita através da utilização do programa ANATEM, desenvolvido pelo CEPEL. Os resultados obtidos mostram as vantagens da utilização das formulações propostas. / This work proposes a new formulation for both the conventional power flow and the optimal power flow formulation, in which the steady-state equations describing the primary and secondary frequency control in electrical power systems are included. The proposed power flow formulation is based on a flexible methodology for the representation of control devices. Such methodology incorporates equations that model control devices into the basic power flow formulation in polar coordinates, generating an augmented system of equations having order (2nb + nc). The developed power flow is able to estimate the system frequency deviation due to a load disturbance. On other hand, the proposed optimum power flow formulation is able to identify the minimum load shedding necessary to maintain the system frequency in an acceptable range of operation. The proposed OPF formulation includes additional equality and inequality constraints to represent the steady state primary frequency control as a function of the active power generation. The proposed development for the conventional power flow was made using the MATLAB® environment. The optimal power flow solution used a commercial optimization package called LINGO®. The evaluation of the proposed power flow and optimal power flow formulations were made through the study of small test systems and the New England test system. Validations of the frequency deviation analysis were made using the program ANATEM, developed by CEPEL. The results obtained show the advantages of using the proposed formulations.

Page generated in 0.0618 seconds