• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 25
  • 5
  • 2
  • 1
  • 1
  • Tagged with
  • 34
  • 7
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Modelización de los sistemas de electrificación ferroviaria, en corriente alterna y continua, con sistemas recuperadores de energía para el estudio de la eficiencia energética

Ratés Palau, Sergio 23 March 2012 (has links)
A detail modelling of railway electrical system with energy storages devices is developed in this thesis in order to analyze most of the implemented railway electrical system. The modelling has been realized from a point of view the design of them as from a point of view of purely energetic efficiency. In this way, after analyzing of the electric railway systems, it has been developed simple element models that have been grouped in four categories: contact line and return circuit, fix elements, mobile elements and energy recovery and storages devices. The complete systems are built from the simple element models linked. The system of equations of the complete system is no linear, and it is solved means of numeric methods. Then, it is shown the structure of Rsim software that has been developed completely as a part of this work, to conclude with two examples of the application of Rsim. The first example belongs an alternative current railway electrification and the second example is a direct current railway electrification. Keywords: DC railway system, AC railway system, railway modeling, energetic efficiency, reverse substations, energy storage devices, unbalance, rail potential, stray currents. A detail modelling of railway electrical system with energy storages devices is developed in this thesis in order to analyze most of the implemented railway electrical system. The modelling has been realized from a point of view the design of them as from a point of view of purely energetic efficiency. In this way, after analyzing of the electric railway systems, it has been developed simple element models that have been grouped in four categories: contact line and return circuit, fix elements, mobile elements and energy recovery and storages devices. The complete systems are built from the simple element models linked. The system of equations of the complete system is no linear, and it is solved means of numeric methods. Then, it is shown the structure of Rsim software that has been developed completely as a part of this work, to conclude with two examples of the application of Rsim. The first example belongs an alternative current railway electrification and the second example is a direct current railway electrification. Keywords: DC railway system, AC railway system, railway modeling, energetic efficiency, reverse substations, energy storage devices, unbalance, rail potential, stray currents.
22

Nuevos métodos de diagnosis de excentricidad y otras asimetrías rotóricas en máquinas eléctricas de inducción a través del análisis de la corriente estatórica

Puche Panadero, Rubén 05 November 2008 (has links)
Las máquinas eléctricas de inducción están presentes en la mayoría de los procesos productivos (suponen alrededor de un 90% del total de máquinas eléctricas existentes en el mercado), gracias a su simplicidad constructiva y a su fiabilidad. Por motivos de producción y sobre todo económicos se hace necesario poder diagnosticas y detectar los posibles fallos que puedan surgir, incluso de modo incipiente, para evitar paradas no programadas con las consecuencias negativas que esto supone. De ahí que en las últimas décadas se hayan realizado inversiones tanto económicas como humanas para investigar y desarrollar técnicas no invasivas que sean capaces de detectar y diagnosticar los fallos o averías que puedan surgir. Además es muy recomendable que estas técnicas puedan ser aplicadas en línea, sin necesidad de parar la máquina eléctrica y bajo cualquier régimen de funcionamiento. Tradicionalmente, la detección y diagnosis de fallos en las máquinas eléctricas se ha realizado en régimen permanente. Inicialmente, se utilizó la medida de las vibraciones de la máquina. Desde hace unos años se está investigando y experimentando con la medida de la corriente estatórica, basándose principlamente en el análisis frecuencial mediante la transformada de Fourier. Recientemente, se están aplicando nuevas técnicas avanzadas de análisis de señal para sustituir a la transformada de Fourier, ya que esta presenta problemas indeseados, como por ejemplo el efecto de dispersión de la señal o comúnmente denominado como efecto "leakage". También se ha comenzado a utilizar señales capturadas en régimen transitorio, principlameante la corriente de la máquina eléctrica consumida en el aarranque, para su posterior análisis mediante la transformada wavelets y a través de esta transformada diagnosticar y detectar las posibles averías. Esta es una de las líneas principales de desarrollo del grupo de investigación al que pertenezco. En la presente tesis se desarrollan cuatro nuevos métodos basados en dif / Puche Panadero, R. (2008). Nuevos métodos de diagnosis de excentricidad y otras asimetrías rotóricas en máquinas eléctricas de inducción a través del análisis de la corriente estatórica [Tesis doctoral no publicada]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/3543 / Palancia
23

High-resolution algorithms for the reconstruction of the equivalent currents of an antenna by means of modal theory and a priori information

Sánchez Escuderos, Daniel 24 May 2010 (has links)
El objetivo del diagnóstico de antenas es la detección de errores en antena fabricadas. Dado que este diagnóstico es difícil de realizar simplemente observando medidas de campo, el diagnóstico se realiza usando las corrientes equivalentes reconstruidas en una superficie próxima a la antena. Esta tesis describe las diferentes posibilidades de realizar esta reconstrucción en una superficie plana a partir de medidas esféricas en campo próximo. En concreto, se estudian extensivamente, y se aplican a situaciones reales, las técnicas de la expansión modal. El problema principal de las técnicas modales es la limitación en la resolución de las corrientes equivalentes. La razón de esta limitación es la pequeña región disponible del espectro de ondas planas (cuya transformada de Fourier son las corrientes equivalentes). En esta tesis se estudia este problema, se muestran varios ejemplos y se describen las posibilidades de mejorar la resolución. De entre estas posibilidades, se propone el uso de una técnica de extrapolación con la que estimar el espectro no visible a partir de la región conocida (el espectro visible) y de información adicional sobre la antena como, por ejemplo, el tamaño de la antena. Entre las diferentes técnicas de extrapolación, se describen y comparan las técnicas más usadas comúnmente. En primer lugar, se aplica el algoritmo iterativo de Papoulis-Gerchberg usando el tamaño y la forma de la antena. Después se describen las versiones directas de este algoritmo, es decir la matriz de extrapolación por filas y columnas y la matriz de extrapolación generalizada. Finalmente, se estudia la transformación PDFT y se compara con los algoritmos anteriores. Todas estas técnicas son aplicadas en situaciones reales con una importante mejora en la resolución. El último capítulo de esta tesis trata de los procedimientos de calibración de sonda. Estos procedimientos son especialmente importantes en el diagnóstico de antenas. / Sánchez Escuderos, D. (2009). High-resolution algorithms for the reconstruction of the equivalent currents of an antenna by means of modal theory and a priori information [Tesis doctoral no publicada]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/8323 / Palancia
24

Aportación al mantenimiento predictivo de motores de inducción mediante modernas técnicas de análisis de la señal

Climente Alarcón, Vicente 29 May 2012 (has links)
La presente tesis cuenta con dos objetivos. Por una parte introducir y validar un método de análisis de corrientes estatóricas para el diagnóstico de máquinas de inducción conectadas a la red que operan en estado transitorio, basado en el uso de filtros de rechazo de frecuencia en combinación con la distribución de Wigner-Ville, con especial interés en su aplicación para la detección incipiente de defectos. El segundo objetivo consiste en replicar de la manera más fidedigna posible el proceso de rotura de una barra en el rótor de un motor de inducción. Para ello se ha diseñado un ensayo encaminado a provocar dicha avería sometiendo un motor a fatiga. Con este objetivo se ha construido un banco de pruebas y emplazado los sensores necesarios, así como un sistema de recogida de datos de manera automatizada. Adicionalmente, se ha diseñado los programas de procesamiento de los mismos, también para ser llevado a cabo de la manera lo más desatendida posible. / Climente Alarcón, V. (2012). Aportación al mantenimiento predictivo de motores de inducción mediante modernas técnicas de análisis de la señal [Tesis doctoral no publicada]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/15915 / Palancia
25

Técnicas de control para la conexión en paralelo de inversores aplicadas a convertidores de interconexión entre los buses de CC y CA de microrredes híbridas e inversores fotovoltaicos centralizados de alta potencia.

Liberos Mascarell, María Antonia 21 June 2021 (has links)
[ES] En este trabajo se proponen técnicas de control específicas para la paralelización de inversores sin transformador conectados a red, en aplicaciones de interconexión de buses de microrredes híbridas e instalaciones fotovoltaicas de gran potencia. La paralelización de inversores presenta múltiples ventajas como la modularidad, la redundancia o la flexibilidad para ampliar la potencia de un sistema o de una instalación. En el caso de inversores fotovoltaicos centralizados, también permite la conexión/desconexión de módulos inversores conectados en paralelo permitiendo una mayor eficiencia global cuando se trabaja a bajas potencias. Sin embargo, la paralelización de inversores provoca la aparición de corrientes de circulación que pueden provocar efectos indeseables en el sistema o en la instalación. Las contribuciones que se llevan a cabo en esta tesis están todas ellas orientadas a la mejora de la operación de inversores en paralelo en las aplicaciones descritas y son las siguientes: 1) Se presenta un modelo preciso en pequeña señal de n inversores conectados en paralelo con filtro de conexión a red LCL, en el cual se tienen en consideración los términos de acoplamiento entre fases de los inductores trifásicos. 2) Se propone una técnica de control en la que se emplean n-1 lazos de regulación que controlan la componente homopolar de las corrientes e imponen un valor nulo en régimen permanente, a fin de eliminar las corrientes de circulación. 3) Se propone el uso de moduladores en espacio vectorial de tres dimensiones (3D-SVM) para implementar el control de la componente homopolar de las corrientes. 4) Se muestran resultados analíticos, de simulación y experimentales que validan el esquema de control propuesto considerando la aparición de corrientes de circulación debido a distintos factores: desbalanceo de inductancias entre las fases de un inversor y de distintos inversores, desbalanceo de potencia entre inversores y empleo de modulaciones distintas en los inversores conectados en paralelo. Los ensayos experimentales se realizan sobre un convertidor trifásico de 10 kW formado por la conexión en paralelo de dos módulos de 5 kW cada uno. 5) Se muestran resultados de simulación y experimentales de la aplicación de las técnicas de reducción de corrientes de circulación a convertidores de interconexión entre los buses de alterna y continua de microrredes híbridas. Los ensayos experimentales se particularizan a un convertidor trifásico de 7.5 kW formado por un módulo de 5 kW y otro de 2.5 kW conectados en paralelo, emulando una eventual ampliación de potencia del 50%. 6) Se lleva a cabo el estudio por simulación de un sistema fotovoltaico de 2 MW compuesto por cuatro inversores de 500 kW conectados en paralelo, demostrando que el control de las componentes homopolares de las corrientes reduce en gran medida el valor de las corrientes de circulación y mejora el desempeño de la instalación. 7) Por último, se propone una técnica de control para mejorar la eficiencia global de inversores fotovoltaicos centralizados de potencia elevada, el cual se basa en la utilización de modelos funcionales bidimensionales de eficiencia para activar/desactivar los módulos de potencia en función del punto de operación del campo fotovoltaico. / [CA] En aquest treball es proposen tècniques de control específiques per a la paral·lelització d'inversors sense transformador connectats a la xarxa, en aplicacions d'interconnexió de busos de micro-xarxes híbrides i instal·lacions fotovoltaiques de gran potència. La paral·lelització d'inversors presenta múltiples avantatges com ara són la modularitat, la redundància o la flexibilitat per ampliar la potència d'un sistema o d'una instal·lació. En el cas d'inversors fotovoltaics centralitzats, també es permet la connexió/desconnexió de mòduls inversors connectats en paral·lel permetent una major eficiència global quan es treballa a potències baixes. En canvi, la paral·lelització d'inversors provoca l'aparició de corrents de circulació que poden provocar efectes indesitjables en el sistema o en la instal·lació. Totes les contribucions que es porten a terme en aquesta tesi estan orientades a la millora de la operació de inversors en paral·lel en les aplicacions descrites i son les següents: 1)Es presenta un model precís en xicoteta senyal de n inversors connectats en paral·lel amb filtre LCL de connexió a xarxa, en el qual es tenen en consideració els termes d'acoblament entre fases dels inductors trifàsics. 2) Es proposa una tècnica de control en la que s'usen n-1 llaços de regulació que controlen la component homopolar de les corrents i imposen un valor nul en règim permanent, a la fi d'eliminar les corrents de circulació. 3) Es proposa l'ús de moduladors en espai vectorial de tres dimensions (3D SVM) per implementar el control de la component homopolar de les corrents. 4) Es mostren resultats analítics, de simulació i experimentals els quals validen l'esquema de control proposat considerant l'aparició de corrents de circulació degut a diversos factors: desbalanceig d'inductàncies entre les fases d'un inversor i de distints inversors, desbalanceig de potència entre inversors i ús de modulacions distintes en els inversors connectats en paral·lel. Els assajos experimentals es realitzen sobre un inversor trifàsic de 10 kW format per la connexió en paral·lel de dos mòduls de 5 kW cadascun. 5) Es mostren resultats de simulació i experimentals de l'aplicació de les tècniques de reducció de corrents de circulació a convertidors d'interconnexió entre els busos d'alterna i contínua de micro-xarxes híbrides. Els assajos experimentals es particularitzen a un convertidor trifàsic de 7.5 kW format per un mòdul de 5 kW i altre de 2.5 kW connectats en paral·lel, emulant una eventual ampliació de potència del 50 %. 6) Es duu a terme l'estudi per simulació d'un sistema fotovoltaic de 2 MW format per quatre inversors de 500 kW connectats en paral·lel demostrant que el control de les components homopolars de les corrents redueixen en gran mesura el valor de les corrents de circulació i millora l'acompliment de la instal·lació. 7) Per últim, es proposa una tècnica de control per a la millora de l'eficiència global d'inversors fotovoltaics centralitzats de potència elevada, el qual es basa en la utilització de models funcionals bidimensionals d'eficiència per activar/desactivar els mòduls de potència en funció del punt d'operació del camp fotovoltaic. / [EN] In this work they have been proposed specific control techniques for the parallelization of transformerless inverters connected to the grid in two specific applications: i) the interlinking converter between ac and dc bus of hybrid microgrids and ii) high power photovoltaic farms. Paralleling of inverters presents some advantages as modularity, redundancy or flexibility for increasing the power of a system or of a plant. In photovoltaic centralized inverters, the parallel inverters can be connected and disconnected in order to improve the global efficiency when the system works at low power. However, the inverters paralleling causes the appearance of circulating currents which can produce undesirable effects in the system or in the plant. The contributions that are carried out in this thesis are all of them aimed at improving the operation of parallel inverters in the described applications and they are as follows: 1) It has been presented an accurate small signal model of n parallel inverters with an LCL grid filter, in which the mutual coupling terms of the three-phase inductors has been considered. 2) It has been proposed a control technique with n-1 control loops that control the zero-sequence current component by setting a zero value in steady state, looking for eliminating the circulating currents. 3) It has been proposed the use of three-dimension space vector modulator (3D SVM) to implement the zero-sequence currents control. 4) The analytical results have been validated by means of simulation and experimental results, showing the performance of the proposed control scheme considering the appearance of circulating currents due to different factors: i) inductor imbalances between the phases of an inverter or ii) between different inverters, iii) power imbalances between inverters and iv) the use of different modulation techniques in the parallel inverters. The experimental tests have been carried out on a 10 kW three-phase converter composed by the parallel connection of two 5 kW modules. 5) They have been shown both simulation and experimental results of the application of circulating current reduction techniques to interlinking converters between the DC and the AC buses of hybrid microgrids. The experimental tests have been particularized to a 7.5 kW three-phase converter composed by a 5 kW and a 2.5 kW module connected in parallel, emulating an eventual 50 % power expansion. 6) Is has been carried out the simulation study of a 2 MW photovoltaic system composed by four 500 kW inverters connected in parallel, showing that the control of the zero-sequence currents greatly reduces the value of the circulating currents and improve the system performance. 7) Finally, it has been proposed a control technique for the improvement of the global efficiency of high power photovoltaic centralized inverters, which is based in the use of bidimensional functional efficiency models to activate/deactivate the power modules according to the operation point of the photovoltaic farm. / Liberos Mascarell, MA. (2021). Técnicas de control para la conexión en paralelo de inversores aplicadas a convertidores de interconexión entre los buses de CC y CA de microrredes híbridas e inversores fotovoltaicos centralizados de alta potencia [Tesis doctoral]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/168190 / TESIS
26

Efecto del Riesgo País sobre las corrientes internacionales de capital: El caso peruano (2000-2020) / Effect of Country Risk on international capital flows

Lopez Alatrista, Gianella Valeria 08 July 2021 (has links)
La presente investigación busca identificar el efecto del riesgo país, medido como el índice EMBI, en conjunto con un grupo de variables macroeconómicas, sobre la Inversión Extranjera Directa (IED) y la Inversión Extranjera de Cartera (IEC) en el Perú. Luego de asegurar la estacionariedad y no autocorrelación de las series de datos mediante transformaciones matemáticas, se aplica la metodología de Vectores Autoregresivos VAR con la finalidad de hallar las variables que explican el desempeño de la IED e IEC durante el periodo comprendido entre los años 2000 y 2020. Los resultados sugieren que el índice EMBI mantiene en el tiempo un efecto negativo sobre la IEC, mientras que en el caso de la IED se observa un efecto positivo durante dos primeros trimestres, el cual posteriormente se diluye hasta disiparse en su totalidad. / This research seeks to identify the effect of country risk, measured as the EMBI Index, together with a group of macroeconomic variables, on Foreign Direct Investment (FDI) and Foreign Portfolio Investment (FPI) in Peru. After ensuring the stationarity and non-autocorrelation of the data series through mathematical transformations, the VAR Autoregressive Vectors methodology is applied in order to find the variables that explain the performance of FDI and FPI during the period between 2000 and 2020. The results suggest that the EMBI index maintains a negative effect on the IEC over time, while in the case of FDI a positive effect is observed during the first two quarters, which subsequently dissipates until it dissipates in its entirety. / Trabajo de investigación
27

Evaluación de la eficacia en la limpieza de sedimentos usando la obra de desvío para la construcción, presa Congalla, Huancavelica

Peña Baca, Gilber 22 September 2021 (has links)
La disminución de las reservas de agua dulce debido al cambio climático y sus efectos cada vez más imprevisibles, requiere de la construcción de nuevas presas y el mantenimiento de la capacidad de almacenamiento de los embalses existentes. Los proyectos de represamiento, generalmente consideran una vida útil de 50 años, producto de los sedimentos que se acumularán en el reservorio. Sin embargo, luego de transcurrido ese tiempo es inviable suspender las actividades generadas alrededor de una presa. Por esto, se requiere prolongar la vida útil de los embalses, mediante prácticas de manejo de sedimentos utilizando las estructuras que componen las presas, lo que involucra menores costos respecto de otras alternativas. Las prácticas de manejo de sedimentos más difundidas son el sluicing, el flushing y la ventilación de corrientes de turbidez. Se requiere una revisión de estas prácticas para implementarlas en el Perú, lo cual se desarrolla en el presente estudio, donde se realiza la evaluación de la presa Congalla. Este proyecto entró en funcionamiento en octubre del 2016, el cual requirió para su construcción de una particular obra de desvío, consistente en un ducto de barriles metálicos. Este ducto luego se convirtió en la descarga de fondo, con 100 m de longitud y 0.60 m de diámetro interno, mucho más de lo necesario técnicamente, pero más económico que otras opciones. Lo que se busca es aprovechar el área de la sección del conducto, para verificar su utilidad para la eliminación de sedimentos. Se ha realizado un análisis de información en gabinete y un arduo trabajo de campo en las temporadas de estiaje y lluvias, en los meses de agosto del 2018 y marzo del 2019 respectivamente. De acuerdo a los cálculos, luego de dos años y medio, se tiene una acumulación de sedimentos de 2793.24 m3 utilizando fórmulas empíricas y de 1633.49 m3 según mediciones efectuadas. Realizando la apertura de la válvula de la descarga, se han obtenido resultados de hasta 1.08% de eliminación de los sedimentos calculados mediante las mediciones, el cual es un buen indicador de la eficacia de limpieza. Los efectos negativos en el ecosistema, de los sedimentos liberados aguas abajo de la presa, fueron indetectables. / Decrease in freshwater reserves due to climate change and its increasingly unpredictable effects, requires the construction of new dams and maintenance of storage capacity of existing reservoirs. Damming projects, generally consider a useful life of 50 years, as a result of sediments that will accumulate in the reservoir. However, after that time has elapsed, it is not feasible to suspend the activities generated around a dam. Therefore, it is necessary to extend the useful life of reservoirs, through sediment management practices using the structures that make up the dams, which involves lower costs compared to other alternatives. Most widespread sediment management practices are sluicing, flushing, and venting of turbidity streams. It is required a review of these practices to implement them in Peru, which is developed in the present study, where evaluation of the Congalla dam is carried out. This project came into operation in October 2016, which required for its construction a particular diversion work, consisting of a metal barrel pipeline. This pipeline later became the bottom discharge, with a length of 100 m and an internal diameter of 0.60 m, much more than technically necessary, but cheaper than other options. What is sought is to take advantage of the duct section’s area, to verify its usefulness for elimination of sediments. An analysis of information has been carried out in office and arduous fieldwork in dry and rainy seasons, in months of August 2018 and March 2019 respectively. According to calculations, after two and a half years, there is an accumulation of sediments of 2793.24 m3 using empirical formulas and 1633.49 m3 according to measurements made. By opening the discharge valve, have been obtained results of up to 1.08% removal of sediments calculated through measurements, which is a good indicator of cleaning efficacy. Negative effects on the ecosystem, from the sediments released downstream from the dam, were undetectable. / Tesis
28

Minority Language Resilience in Corrientes, Argentina: Argentine Guarani and Spanish in Contact

Pinta, Justin 12 September 2022 (has links)
No description available.
29

Study on conduction mechanismes of mediun voltage cable XLPE insulation in the melting range of temperatures.

Orrit Prat, Jordi 07 March 2012 (has links)
D’ençà que el polietilè reticulat (XLPE) es va començar a utilitzar com aïllament elèctric per cables de subministrament elèctric, s’han destinat molts esforços a l’estudi de les propietats dielèctriques del polietilè i l’efecte que la càrrega d’espai té sobre el seu comportament. En aquest sentit, les corrents de despolarització estimulades tèrmicament (TSDC) s’han utilitzat extensament per estudiar les relaxacions de càrrega d’espai. Aquesta tècnica ha demostrat tenir prou resolució per distingir diferències en aïllaments de XLPE amb composicions o processos de fabricació diferents. En aquesta tesi, els mecanismes de conducció dels aïllaments XLPE de cables de mitjana tensió (MV) han estat estudiats per TSDC i diverses tècniques complementàries, com l’anàlisi dinàmica elèctrica (DEA), les corrents d’absorció/resorció (ARC), el pols electroacústic (PEA) i les corrents de despolarització isotèrmiques (IDC). Altres tècniques, com l’espectroscòpia d’infrarojos (FTIR) o la difracció de raigs X, han estat també utilitzades per caracteritzar el material. S’han obtingut espectres TSDC per diferents mostres de cable, les quals en condicions de servei treballen en un rang de tensió AC de 12 a 20kV i a temperatures al voltant dels 90ºC. D’altra banda, s’han realitzat mesures de la conductivitat per ARC i DEA en mostres de cable, en cilindres de XLPE i en films. Les mesures s’han dut a terme a temperatures pertanyents al rang de fusió del XLPE (50–110ºC), en mostres sotmeses a aquestes temperatures durant diferents períodes de temps. Els resultats mostren diferències importants entre el comportament de les propietats conductives de les mostres de cable amb pantalles semiconductores (SC) i sense (cilindres de XLPE). El comportament observat ha estat explicat mitjançant la coexistència de dos mecanismes de conducció. La difusió d’impureses des de les pantalles SC determina el comportament d’una d’aquestes contribucions a mig i llarg termini. Els resultats obtinguts per FTIR són consistents amb aquest model. Respecte la microestructura, tant les mesures DSC com la difracció per raigs X mostren que existeixen processos de recristal•lització quan les mostres són sotmeses a temperatures ubicades dins del rang de fusió. Els electrets formats mitjançant el mètode de la polarització per finestres (WP) mostren una descàrrega TSDC amb un ample pic heteropolar en el rang de fusió, amb el màxim al voltant dels 105ºC. En treballs previs, aquest pic es va associar a la fusió de la fracció cristal•lina. Tanmateix, en lloc de decréixer quan la temperatura de polarització augmenta, el pic presenta una temperatura de polarització òptima al voltant de 90-95ºC. Aquest comportament ha estat explicat tenint en compte els processos de recristal•lització que es produeixen quan el material es polaritza isotèrmicament. Durant la recristal•lització, una nova fracció cristal•lina creix en un estat polaritzat degut el camp aplicat, i origina una corrent de despolarització quan es fon durant la mesura TSDC. Amb l’objectiu de determinar l’origen d’altres pics que apareixen en l’espectre TSDC del XLPE, s’han emprat les IDC com a tècnica complementària. Les corrents IDC obtingudes de mostres no tractades es poden representar com la combinació de dues contribucions diferenciades: un terme que és una funció potencial del temps i un d’exponencial. La segona relaxació es correspon amb un pic TSDC que apareix a 95ºC. D’aquesta manera s’ha pogut determinar l’origen dipolar del pic. Finalment, mitjançant la tècnica PEA s’ha obtingut la distribució de la càrrega d’espai en mostres polaritzades que havien estat sotmeses a diferents tractaments tèrmics. S’ha observat un comportament transitori tant per PEA com per TSDC. Tanmateix no s’ha pogut establir cap relació directa entre les descàrregues TSDC i mesures PEA. En conseqüència, s’ha proposat una explicació per les corbes TSDC que considera mecanismes que no són detectables en els perfils de càrrega obtinguts per PEA / Since cross-linked polyethylene (XLPE) started to be used as electrical insulation for power cables, much research has been focused on polyethylene dielectric properties and the effect of the space charge on its behavior. In this sense, thermally stimulated depolarization currents (TSDC) have been widely used to study space charge relaxation. This technique has proved to have enough resolution to determine differences in charge trapping properties among XLPE insulations with different composition and manufacturing processes. In this thesis work, the conduction mechanisms of medium voltage (MV) cable XLPE insulation have been studied by TSDC and several complementary techniques, such as dynamic electrical analysis (DEA), absorption/resorption currents (ARC), pulsed electroacoustic (PEA) and isothermal depolarization currents (IDC). Other techniques, like Fourier transform infrared (FTIR) spectroscopy or X-ray diffractometry, have been used to characterize the material. TSDC spectra have been obtained for different cable samples, which in service conditions work under AC voltages ranging from 12 to 20kV and at temperatures around 90ºC. On the other hand, conductivity measurements by ARC and DEA have been performed in cable samples and in XLPE cylinders, as well as XLPE films. Measurements have been carried out at temperatures within the melting temperature range of XLPE (50–110ºC) on samples annealed at such temperatures during several annealing times. Results show significant differences in the behavior of the conductive properties of XLPE cable samples with semiconducting (SC) screens and without them (XLPE cylinders). The observed behavior has been explained by the coexistence of two conduction mechanisms. Diffusion of impurities from SC screens determines the medium and long-term behavior of one of these contributions and, hence, of cable conductivity. FTIR results are consistent with this model. With respect to microstructure, DSC and X-ray diffractometry results show that recrystallization processes exist when samples are annealed in the melting range of temperatures. Electrets formed by means of the windowing polarization method (WP) showed a TSDC discharge with a wide heteropolar peak in the melting temperature range, and with the maximum at about 105ºC. This peak was associated with the melting of the crystalline fraction in previous works. However, in spite of decreasing with the temperature of polarization, an optimal polarization temperature around 90–95ºC is found. This behavior has been explained by taking into account recrystallization processes when the insulation is isothermally polarized. During recrystallization, the new crystalline fraction grows in a polarized state due to the applied electric field, and it causes the depolarization current when it melts during the TSDC measurement. Results obtained from different experiments are consistent with this assumption. With the aim to find out the origin of other TSDC peaks present in the spectrum of XLPE cable samples, IDC has been used as complementary technique. IDC currents obtained from as-received cable samples at temperatures close to service conditions can be considered as the combination of two different contributions: a power law current and a stretched exponential contribution. The last relaxation process has been successfully associated with with a TSDC peak found at 95ºC. By this way the dipolar origin of the peak has been determined. Finally, PEA measurements have provided the space charge distribution profiles of polarized samples with different annealings. A transient behavior has been observed in both PEA and TSDC measurements. However, no straightforward relation between TSDC discharges and space charge detected by PEA can be established. Therefore, an explanation for TSDC curves has been proposed, which considers mechanisms that are not noticeable in charge profiles obtained by PEA.
30

A formulação da política de segurança alimentar no Peru 2001-2006: um estudo de caso no departamento de Puno.

Montaño, Edgard Manuel Hito January 2009 (has links)
p. 1-191 / Submitted by Santiago Fabio (fabio.ssantiago@hotmail.com) on 2013-04-25T19:23:41Z No. of bitstreams: 1 22222.pdf: 1803793 bytes, checksum: 908f049302ffed4b26a9995cc14b52a8 (MD5) / Approved for entry into archive by Maria Creuza Silva(mariakreuza@yahoo.com.br) on 2013-05-04T17:36:37Z (GMT) No. of bitstreams: 1 22222.pdf: 1803793 bytes, checksum: 908f049302ffed4b26a9995cc14b52a8 (MD5) / Made available in DSpace on 2013-05-04T17:36:37Z (GMT). No. of bitstreams: 1 22222.pdf: 1803793 bytes, checksum: 908f049302ffed4b26a9995cc14b52a8 (MD5) Previous issue date: 2009 / En el Perú una cuarta parte de niños menores de 5 años se encuentran en desnutrición crónica y la evolución de este indicador desde 1996 prácticamente se ha mantenido igual. En el departamento de Puno el problema aún es mayor por sus condicionantes socio-económicas y políticas. Después del ajuste estructural provocado por los cambios del sistema económico, la mitad de la población peruana, pasó al estado de pobreza y una cuarta parte a la extrema pobreza; siendo afectado el acceso a los alimentos por parte de las familias peruanas, es aquí donde la política alimentaria formó parte del programa. En el periodo del gobierno de Alberto Fujimori y Alejandro Toledo se incrementó el financiamiento en programas alimentarios, trabajándose aún innovaciones en la gestión de estos programas. Producto de esta realidad social, el Perú se encuentra en la inseguridad alimentaria. Pese a las iniciativas y esfuerzos realizados por el estado peruano por disminuir la inseguridad alimentaria se observa aún instituciones públicas y privadas en la yuxtaposición de implementación de políticas alimentarias. El objetivo de la investigación fue describir y analizar el proceso de formulación de las políticas de seguridad alimentaría en el departamento de Puno – Perú durante el periodo 2001 al 2006. Utilizamos el enfoque teórico - metodológico del ciclo de la política enfatizando sobre el modelo de las ―múltiples corrientes‖. Este estudio de caso utilizó la revisión documental y las entrevistas en profundidad aplicadas a los ―informantes clave‖. Estas informaciones fueron procesadas, descritas y analizados para caracterizar el contexto nacional y regional; obtener las racionalidades de los actores en el proceso de formulación de la política de seguridad alimentaria; así como identificar a los emprendedores políticos que facilitó la reconstrucción del momento de predecisión, decisión y la apertura de la ―ventana política o de oportunidad‖ que condujo a la formulación de la Estrategia Nacional de Seguridad Alimentaria 2004-2015 y la Estrategia Regional de Seguridad Alimentaria – Puno 2006-2015. Constatamos que estas políticas aún tienen dificultad para implementarse, existiendo vacío de responsabilidades y articulación con los planes sectoriales, a pesar de haber obtenido apoyo general de la comunidad política para su formulación. Observándose que el gobierno de Alejandro Toledo (2001-2006) promovió el dialogo y la negociación con la sociedad civil, todavía insuficiente para el enfrentamiento de la inseguridad alimentaria. / Salvador

Page generated in 0.0674 seconds