• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 69
  • Tagged with
  • 69
  • 69
  • 28
  • 25
  • 24
  • 21
  • 17
  • 17
  • 13
  • 13
  • 13
  • 12
  • 11
  • 11
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Isolamento, identificação e controle de microorganismos presentes em estruturas metálicas corroídas na usina hidroelétrica Coaracy Nunes

Correia, Amabel Fernandes January 2009 (has links)
Dissertação (Mestrado em Ciencias da Saúde)—Universidade de Brasília, Programa de Pós-graduação em Ciências da Saúde. / Texto parcialmente liberado pelo autor. Conteúdo disponível: Resumo. / Submitted by Jaqueline Ferreira de Souza (jaquefs.braz@gmail.com) on 2013-02-26T14:35:15Z No. of bitstreams: 1 2009_AmabelFernandesCorreia.pdf: 20362 bytes, checksum: 0385bb291e80298c8e516de7671240e0 (MD5) / Approved for entry into archive by Jaqueline Ferreira de Souza(jaquefs.braz@gmail.com) on 2013-02-26T14:35:39Z (GMT) No. of bitstreams: 1 2009_AmabelFernandesCorreia.pdf: 20362 bytes, checksum: 0385bb291e80298c8e516de7671240e0 (MD5) / Made available in DSpace on 2013-02-26T14:35:39Z (GMT). No. of bitstreams: 1 2009_AmabelFernandesCorreia.pdf: 20362 bytes, checksum: 0385bb291e80298c8e516de7671240e0 (MD5) / Corrosão é o processo espontâneo de deterioração, que ocorre em superfícies de materiais metálicos e não metálicos, por meio de reações químicas ou eletroquímicas, influenciada por vários fatores físicos, químicos e biológicos. Dentre os fatores biológicos, destacam-se os produtos do metabolismo microbiano e a formação de biofilme, capazes de modificar a interface substrato/solução, facilitando, iniciando, acelerando ou inibindo as reações de corrosão, sem alterar sua natureza eletroquímica. O processo corrosivo sob influência de microorganismos, denominado de biocorrosão, corrosão microbiológica ou corrosão influenciada microbiologicamente, representa grande problema mundial e acarreta elevadas perdas econômicas, além de danos ambientais. Na busca de alternativas para o controle e prevenção da corrosão influenciada microbiologicamente, este trabalho teve como principal objetivo detectar e caracterizar microorganismos, presentes nas estruturas metálicas corroídas e na água das tubulações da Usina Hidroelétrica Coaracy Nunes, localizada no estado do Amapá, bem como, testar 30 extratos brutos, obtidos de plantas medicinais coletadas na região amazônica do Amapá, quanto à ação antimicrobiana frente aos microorganismos isolados dos materiais coletados na usina. Para isto, técnicas microbiológicas, moleculares, de microscopia eletrônica e espectroscopia foram utilizadas. As técnicas microbiológicas de cultivo, de identificação bioquímica e da avaliação da atividade antimicrobiana, permitiram a caracterização de microorganismos das famílias Enterobacteriacea, Pseudomonadaceae, Bacillaceae, Corynebacteriaceae, Enterococcaceae, Dematiaceae e Moniliaceae e a demonstração da atividade antimicrobiana de 5 extratos frente a Pseudomonas aeruginosa e bactérias do gênero Bacillus. Na amplificação gênica pela reação em cadeia de polimerase (Polymerase Chain Reaction - PCR), foi detectado fragmento de 1300 pares de base correspondendo ao gene 16S rRNA, evidenciando a presença de microorganismos do domínio Arquea, e na análise por microscopia eletrônica de varredura e espectroscopia de energia dispersiva por raios – X, foi detectado a formação de biofilme e o potencial corrosivo das comunidades microbianas presentes no material coletado na usina. A importância destes achados, não só representam tentativas de controle da corrosão influenciada microbiologicamente in locu, como também promove o desenvolvimento sócio-econômico das populações circunvizinhas à usina, com relação a produção e comercialização de plantas medicinais como potenciais anticorrosivos/antimicrobianos. _______________________________________________________________________________________ ABSTRACT / Corrosion is a spontaneous deterioration process that occurs over metallic and non-metallic material surfaces by chemical or electrochemical reactions, influenced by several physical, chemical and biological variables. Among the biological factors the products of microbial metabolism and biofilm formation are included which could modify the interface between substrate and solution, facilitating, initiating, accelerating or inhibiting the corrosion reactions, without changing its electrochemical nature. The corrosive process under the influence of microorganisms, called biocorrosion, microbiological corrosion or microbiologically influenced corrosion, represents an enormous global problem and causes huge economic losses and environmental damage. In search of alternative solutions for controlling and preventing the microbiologically influenced corrosion, this work aimed at detecting and characterizing microorganisms in corroded metal structures and water pipelines in the Coaracy Nunes Hydroelectric power plant, located in the state of Amapá, and, assaying 30 ethanolic crude extracts obtained from medicinal plants harvested in the Amazon region of Amapá, against microorganisms isolated from corroded materials collected at the power plant. In order to accomplish these objectives, microbiological and molecular biology techniques, as also electron microscopy and spectroscopy analysis have been employed. Techniques of microbiological cultivation, biochemical identification and evaluation of antimicrobial activity, allowed the characterization of microorganisms belonging to the Enterobacteriaceae, Pseudomonadaceae, Bacillaceae, Corynebacteriaceae, Enterococaceae, Dematiaceae and Moniliaceae families, besides the detection of antimicrobial activity exerted by 5 plant ethanolic crude extracts against Pseudomonas aeruginosa and the Bacillus genus. By genomic amplification utilizing the polymerase chain reaction, it was found a fragment of 1300 base pairs corresponding to the 16S rRNA gene, evidencing the presence of Archea domain microorganisms. Analysis by the scanning electron microscopy and the X ray energy dispersion techniques detected biofilm formation and the corrosive potential of microbial communities present in the material collected at the power plant. The importance of these findings not only represents attempts to control microbiologically influenced corrosion in locu, but also promote the socioeconomic development of the power plant surrounding populations regarding the production and marketing of medicinal plants as potential anticorrosive/antimicrobials.
12

Efeito do revestimento anti-corrosivo nas propriedades de soldas de aços alta resistencia

Lima, Carlos Roberto Camello 23 April 1993 (has links)
Orientador: Roseana da Exaltação Trevisan / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-07-18T09:11:09Z (GMT). No. of bitstreams: 1 Lima_CarlosRobertoCamello_M.pdf: 3582751 bytes, checksum: 99b6ac62305aa5c6f1b8ccfa89f70420 (MD5) Previous issue date: 1993 / Resumo: Neste trabalho é proposto um estudo sistemático da influência de tintas de proteção anti-corrosiva na formação de trincas a frio em soldas de aços alta resistência SAR-50. A avaliação das trincas é feita através do auto restrição TEKKEN com preparação em "Y" oblíquo. Os teste de resultados são apresentados de maneira comparativa entre soldas efetuadas sôbre superfícies pintadas e sem pintura. As trincas são analisadas em relação à quantidade, localização, origem e tamanho. A espessura da chapa de aço SAR-50 utilizada é de 25 mm e as tintas de proteção para o revestimento superficial são Zinco Etil Silicato e Epoxi óxido de Ferro, as quais são aplicadas em espessuras variadas. Dos resultados obtidos, nas condições experimentais efetivadas, pode-se constatar principalmente que, otimizadas as condições de soldagem, a influência da condição do revestimento superficial não é significativa na susceptibilidade do aço SAR-50 à formação de trincas a frio / Abstract: This work proposes a systematic study of the influence of anti-corrosion coating paints on the SAR-50 high-strenght steel welds cold cracking. The self-restraint Y-groove Tekken test is used to investigate the cracks. The results are presented in a comparativa way among joints in coated and uncoated surfaces. The cracks are studied in relation to number, location, source and size A 25 mm thick SAR-50 steel plate is used as specimen material. The protective paints used as surface coatings are zinc-silicate and epoxiones, which are applied in several thicknesses. From the results, which were obtained under specific experimental conditions, we can see that, provided welding conditions are appropriate, the surface coating condition do not have a significative influence on the SAR-50 steel cold cracking suscepbility / Mestrado / Mestre em Engenharia Mecânica
13

Desenvolvimento e estudos de tintas epÃxis anticorrosivas ecologicamente corretas / Development and studies of environmental friendly epoxies anticorrosive paints

Adriana de Oliveira Sousa Leite 11 February 2004 (has links)
CoordenaÃÃo de AperfeiÃoamento de Pessoal de NÃvel Superior / Esse trabalho à o inÃcio de uma nova linha de pesquisa do laboratÃrio de eletroquÃmica da UFC que busca desenvolver tintas com alternativas de utilizaÃÃo de pigmentos tÃxicos e matÃrias-primas ditas ecologicamente corretas. Neste sentido este trabalho descreve o desenvolvimento e estudo de tintas ecologicamente corretas formuladas usando fosfato de zinco (ZP), molibdato de zinco (ZM), molibdato de zinco e cÃlcio (ZCM), fosfomolibdato de zinco (ZMP) e fosfomolibdato de zinco e cÃlcio (ZCMP), como alternativas seguras aos pigmentos anticorrosivos tradicionais (chumbo, cromo e outros metais pesados). Adicionalmente, consideraÃÃes ambientais tÃm limitado o uso de tintas organossolÃveis devido estas contribuÃrem para a poluiÃÃo atmosfÃrica e problemas de saÃde. Assim, resinas epÃxis hidrossolÃveis foram usadas na formulaÃÃo das tintas epÃxis anticorrosivas. O principal objetivo deste trabalho à empregar pigmentos de molibdatos para avaliar sua eficiÃncia contra corrosÃo em tintas hidrossolÃveis. As propriedades inibidoras dos pigmentos foram avaliadas por curvas de polarizaÃÃo potenciodinÃmica, monitoramento do potencial de circuito aberto e perda de massa por imersÃo de substratos ferrosos (SAE 1010) em soluÃÃo saturada dos pigmentos em 10-2 mol dm-3 NaCl. A caracterizaÃÃo fÃsico-quÃmica dos produtos de corrosÃo foi avaliada por microscopia eletrÃnica de varredura, energia dispersiva de raios-X e difraÃÃo de raios-X. Todos os testes mostraram que os pigmentos fosfomolibdatos apresentaram as melhores propriedades inibidoras de corrosÃo. Todas as tintas foram formuladas com 16% (v/v) de resina epÃxi, 7,5% (v/v) de pigmentos anticorrosivos, e demais componentes e aditivos para manter a relaÃÃo de PVC/CPVC em 0,8. A espessura da pelÃcula seca de tinta nos painÃis ficou em aproximadamente 120 μm. O desempenho das tintas foi monitorado por impedÃncia eletroquÃmica durante os testes de imersÃo, de exposiÃÃo atmosfÃrica e de cÃmara acelerado de nÃvoa salina. A estabilidade tÃrmica foi estudada por anÃlise tÃrmica e calorimetria exploratÃria diferencial. Os diagramas de impedÃncia de todas as tintas mostraram somente um arco capacitivo, com os valores de impedÃncia maiores que 109 Ωcm2. os valores de capacitÃncia variaram entre 10-6 e 10-10 Fcm-2. Os resultados sugerem que a combinaÃÃo do molibdato e fosfato fornecem as melhores propriedades inibidoras Ãs tintas. Em relaÃÃo Ãs anÃlises tÃrmicas foi possÃvel concluir que os pigmentos de molibdatos e fosfomolibdatos apresentaram o melhor desempenho tanto em relaÃÃo à estabilidade tÃrmica da resina epÃxi, uma vez que estes pigmentos mostraram maior interaÃÃo entre pigmento-resina, assim como em relaÃÃo à energia envolvida no processo de cura do filme polimÃrico, pois estes pigmentos demonstraram que contribuem para a diminuiÃÃo do calor envolvido no processo de cura. / This work describes the development and study of environmental friendly epoxies anticorrosives paints, which were formulated using zinc phosphate (ZP), zinc molybdate (ZM), zinc and calcium molybdate (ZCM), zinc phosphomolybdate (ZMP) and zinc and calcium phosphomolybdate (MZAP), as safe alternative to more traditional anticorrosive pigments (lead, chromium and other heavy metals). Additionally, environmental considerations are limiting the use of solvent-borne paints because it contibutes to atmospheric pollution and empairs health problems. Thus, hydrosoluble epoxy resin was used in the formulation of the water-borne paints. The aim od this research is to employ molybdate-based pigments in order to check their efficiency in water borne paints. Inhibitive properties of the pigments were evaluated by potentiodynamic polarization curves, open ciricuit potential (Eoc) and mass loss monitoring during 30 days in immersion test of SAE 1010 steel in aqueous saturated pigment solutions with 10-2 mol dm-3 NaCl. The physical chemical characterization of the corrosion products was carried out by scanning electron microscopy, energy dispersive X-ray and X-ray diffraction techniques. All the tests showed that the phosphomolybdate pigments presented the better corrosion inhibiting properties. All the paints were formulated with 16% (v/v) epoxy resin, 7.5 % (v/v) anticorrosive pigment, and additives and fillers in order to maintain the PVC/CPVC ration equal to 0.8. the dry thickness of the painted samples was approximately 120 μm. The paint performance was monitored by electrochemical impedance spectroscopy (EIS) during immersion tests, of the atmospheric exposition and accelerated ensay of salt spray. The thermal stability of the paintings was also studied by thermal gravimetry and differential scanning calorimetry. The impedance diagrams of all painted samples showed only one capacitive loop, with impedance values higher than 109 Ωcm2. Capacitance values varied between 10-6 and 10-10 Fcm-2. The results suggest that the combination of the molybdate and phosphate gives the best inhibitive properties. About the thermal analyses were observed that the molybdates and phosphomolybdates pigments showed the better performances thus in the thermal stability of epoxy resin, because theses pigments showed higher interaction between pigment-resin; just as in the relation the energy involved in the cure process of polymeric film, because these pigments contribued to reduce the heat involved in the cure process.
14

ESTUDO DE TINTAS EPÃXIS à BASE DâÃGUA UTILIZANDO PIGMENTOS ANTICORROSIVOS ATÃXICOS

Francisco Ivanildo Abreu Fernandes 18 March 2008 (has links)
nÃo hà / Foi verificado o desempenho anticorrosivo de tintas epÃxis à base dâÃgua, especialmente formuladas para este trabalho, pigmentadas com cromato de zinco (CZ), fosfato de zinco (FZ), fÃsforo molibdato de zinco e cÃlcio (M) e sÃlica trocadora de cÃlcio (CS). O processo foi conduzido pela exposiÃÃo das amostras à atmosfera natural marinha, em cabine de nÃvoa salina e em imersÃo total em soluÃÃo 10-2 mol.dm-3 de NaCl. Todos os ensaios, quanto à corrosÃo, foram monitorados por espectroscopia de impedÃncia eletroquÃmica e potencial de circuito aberto. Teste de aderÃncia, verificaÃÃo de empolamento e inspeÃÃo visual das superfÃcies serviram como exames complementares. Os resultados sugerem que as tintas apresentaram um bom desempenho em atmosfera marinha e teste de nÃvoa salina. Contudo, sua performance nÃo foi boa em ensaios de imersÃo total.
15

Estudo de tintas epóxis à base d’água utilizando pigmentos anticorrosivos atóxicos / Study epoxy paint water-based anti-corrosion using non-toxic pigments

Fernandes, Francisco Ivanildo Abreu 18 March 2008 (has links)
FERNANDES, F. I. A. Estudo de tintas epóxis à base d’água utilizando pigmentos anticorrosivos atóxicos. 2008. 74 f. Dissertação (Mestrado em Ciência de Materiais) – Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2008. / Submitted by Marlene Sousa (mmarlene@ufc.br) on 2016-03-31T16:27:13Z No. of bitstreams: 1 2008_dis_fiafernandes.pdf: 12446554 bytes, checksum: 6d25eaadae2d35e2bb29c9435bb15ccf (MD5) / Approved for entry into archive by Marlene Sousa(mmarlene@ufc.br) on 2016-04-07T17:36:28Z (GMT) No. of bitstreams: 1 2008_dis_fiafernandes.pdf: 12446554 bytes, checksum: 6d25eaadae2d35e2bb29c9435bb15ccf (MD5) / Made available in DSpace on 2016-04-07T17:36:28Z (GMT). No. of bitstreams: 1 2008_dis_fiafernandes.pdf: 12446554 bytes, checksum: 6d25eaadae2d35e2bb29c9435bb15ccf (MD5) Previous issue date: 2008-03-18 / Anticorrosion performance was verified epoxy water-based inks, especially formulated for this study, pigmentary zinc chromate (CZ), zinc phosphate (FZ), phosphorus molybdate and calcium zinc (M) and silica calcium exchanger (CS). The process was conducted by exposing the samples to the natural marine atmosphere in the cabin of salt spray and total immersion in solution 10-2 mol.dm-3 NaCl. All tests for corrosion were monitored by electrochemical impedance spectroscopy and open circuit potential. adhesion test, shoaling check and visual inspection of surfaces served as complementary tests. The results suggest that the inks showed good performance in marine atmosphere and salt spray test. However, his performance was not good in total immersion tests. / Foi verificado o desempenho anticorrosivo de tintas epóxis à base d’água, especialmente formuladas para este trabalho, pigmentadas com cromato de zinco (CZ), fosfato de zinco (FZ), fósforo molibdato de zinco e cálcio (M) e sílica trocadora de cálcio (CS). O processo foi conduzido pela exposição das amostras à atmosfera natural marinha, em cabine de névoa salina e em imersão total em solução 10-2 mol.dm-3 de NaCl. Todos os ensaios, quanto à corrosão, foram monitorados por espectroscopia de impedância eletroquímica e potencial de circuito aberto. Teste de aderência, verificação de empolamento e inspeção visual das superfícies serviram como exames complementares. Os resultados sugerem que as tintas apresentaram um bom desempenho em atmosfera marinha e teste de névoa salina. Contudo, sua performance não foi boa em ensaios de imersão total.
16

Revestimento por soldagem MIG/MAG empregando ligas de níquel para apliacações em componentes do setor de petróleo e gás natural / Gmaw welding overlay of nickel-based alloys for applications in oil and natural gas components

Aguiar, Willys Machado 03 December 2010 (has links)
AGUIAR, W. M. Revestimento por soldagem MIG/MAG empregando ligas de níquel para apliacações em componentes do setor de petróleo e gás natural. 2010. 255 f. Tese (Doutorado em Ciência de Materiais) – Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2010. / Submitted by Marlene Sousa (mmarlene@ufc.br) on 2016-04-01T12:45:12Z No. of bitstreams: 1 2010_tese_wmaguiar.pdf: 11469085 bytes, checksum: ad569a47a6eb6c3df23c570d0f0627f5 (MD5) / Approved for entry into archive by Marlene Sousa(mmarlene@ufc.br) on 2016-04-07T18:11:42Z (GMT) No. of bitstreams: 1 2010_tese_wmaguiar.pdf: 11469085 bytes, checksum: ad569a47a6eb6c3df23c570d0f0627f5 (MD5) / Made available in DSpace on 2016-04-07T18:11:42Z (GMT). No. of bitstreams: 1 2010_tese_wmaguiar.pdf: 11469085 bytes, checksum: ad569a47a6eb6c3df23c570d0f0627f5 (MD5) Previous issue date: 2010-12-03 / The weld overlay of nickel-based alloys is an alternative often used in oil and gas industry to prevent corrosion in pipes and equipments operating under severe conditions. In many situations the requirements of weld overlays are based in a maximum of 5% iron content in the weld metal to ensure corrosion resistance. The aim of this study was to determine the main welding parameters used in GMAW process to obtain coatings with iron content less than 5%, as well as, to analyze the mechanical properties, metallurgical behavior and corrosion resistance of the weld overlays. To evaluate the welding parameters was used as an analysis tool, the Taguchi method. Initially, the welds with nickel alloys were carried out in simple deposition on ASTM 516 Gr 60 steel plates in the flat position. Based on these results some parameters were selected to deposition of the coatings. In this work were used as filler metal three nickel-based alloys: AWS ERNiCrMo-3, AWS ERNiCrMo-4 and AWS ERNiCrMo-14. The microstructure analysis consisted of optical microscopy, scanning electron microscopy (SEM) and transmission electron microscopy (TEM), energy dispersive of X-ray spectroscopy (EDS) and X-ray diffraction (XRD). Cyclic polarization tests (ASTM G 61-09) and immersion (Method C of ASTM G 48-09) were carried out to evaluate the corrosion resistance of the welds. Microhardness tests and shear test were used to evaluate the mechanical properties. The results showed that the optimal welding conditions were obtained when pulsed current mode was employed, resulting in coatings with a good surface appearance, without defects, and with low dilution level, beyond reinforcement/width (R/W) ratios and reinforcements satisfactory. For coatings with thickness around 5 mm was required to deposit at least two layers. It was found that low dilution level in the first layer is essential to achieve a low iron content (<5%), considering the metal removal by machining to improvement the surface finish. The best cost-benefit for the combination of welding parameters between the layers was found to be the low dilution in the first layer and a high productivity in the second The microstructure of coatings deposited with the alloy AWS ERNiCrMo-3 consisted of a γ matrix with secondary phases rich in Nb like Laves phase and a complex of titanium nitride/niobium carbide. The microstructure of coatings deposited with the alloys AWS ERNiCrMo-4 and AWS ERNiCrMo-14 consisted of a γ matrix and secondary phases rich in Mo (σ, P e μ). The results of shear test showed that the shear interface between the coating/substrate is about three times the half the stress required by ASTM A 265-09. The electrochemical polarization test was not able to evaluate the performance of coatings for corrosion pitting, while the immersion test according to Method C of ASTM G 48, was capable to distinguish the corrosion resistance through the critical pitting temperature (CPT). Based on the results of this test it was possible to verify that the alloy AWS ERNiCrMo-14 resist up to the maximum temperature established by standard (>85 oC). The alloy AWS ERNiCrMo-4 was corroded between 75 oC and 80 oC. Finally, the alloy AWS ERNiCrMo-3 presented the worst resulted compared to the other alloys, has been corroded in the 50 oC, showing a different behavior in terms of corrosion resistance of the alloys deposited. / A soldagem de revestimento com ligas a base de níquel é uma alternativa bastante utilizada no setor de petróleo e gás natural para evitar a corrosão em dutos e equipamentos que operam em condições severas. Em muitas situações exige-se no revestimento, um teor máximo de ferro de 5% para garantir a resistência à corrosão. O objetivo deste trabalho foi determinar os principais parâmetros de soldagem do processo MIG/MAG de forma a obter revestimentos adequados com teor de ferro inferior a 5%, bem como analisar as suas propriedades mecânicas, comportamento metalúrgico e resistência à corrosão. Na determinação dos parâmetros de soldagem foi utilizado como ferramenta de análise, o método Taguchi. Inicialmente, as soldagens com as ligas de níquel foram realizadas em simples deposição sobre chapas de aço ASTM 516 Gr 60 na posição plana. Em seguida, com os parâmetros selecionados, foram realizadas as soldagens de revestimento. No trabalho foram utilizadas as ligas AWS ERNiCrMo-3, AWS ERNiCrMo-4 e AWS ERNiCrMo-14. A caracterização microestrutural consistiu de análises de microscopia ótica, microscopia eletrônica de varredura (MEV) e de transmissão (MET), espectroscopia por dispersão de energia de raios-X (EDX) e difração de raios-X (DRX). Ensaios de polarização cíclica (ASTM G 61 – 86) e de imersão (método C da ASTM G 48–86) foram realizados para avaliar a resistência à corrosão dos revestimentos. Ensaios de microdureza e de arrancamento foram utilizados para a determinação das propriedades mecânicas. Os resultados mostraram que as melhores condições de soldagem foram obtidas com o modo corrente constante pulsada que proporcionou revestimentos com um bom aspecto superficial, sem a incidência de defeitos, menores diluições e com razões reforço/largura (R/L) e reforços satisfatórios. Para revestimentos com espessura em torno de 5 mm foi necessária a deposição de no mínimo duas camadas. Foi constatado que é fundamental obter diluições próximas de 5% já na primeira camada, para garantir uma espessura com baixo teor de ferro, em caso de retirada de um sobremetal no revestimento. A melhor relação custo x benefício para a combinação dos parâmetros de soldagem entre as camadas foi a que proporcionou uma baixa diluição na primeira camada e uma alta produtividade na segunda. A microestrutura dos revestimentos depositados com a liga AWS ERNiCrMo 3 foi constituída por uma matriz γ com fases secundárias Laves e um complexo nitreto de titânio/carboneto de nióbio. A microestrutura dos revestimentos depositados com as ligas AWS ERNiCrMo-4 e AWS ERNiCrMo-14 foi constituída por uma matriz γ e fases secundárias ricas em Mo (σ, P e μ). Os resultados dos ensaios de arrancamento mostraram que a resistência ao cisalhamento entre a interface revestimento/substrato é cerca de três vezes e meia o exigido pela norma ASTM A 265-09. O ensaio de polarização eletroquímica não se mostrou capaz de avaliar o comportamento dos revestimentos quanto à corrosão por pites, enquanto que o ensaio de imersão, segundo o método C da norma ASTM G 48, foi capaz de diferenciá-las quanto à temperatura crítica de pite (TCP). Neste ensaio, a liga AWS ERNiCrMo-14 foi a que apresentou a maior TCP (>85 ºC). Em seguida ficou a liga AWS ERNiCrMo-4 com uma TCP entre 75 ºC e 80 ºC. Por último ficou a liga AWS ERNiCrMo-3 com uma TCP de 50 ºC, mostrando haver uma maior resistência à corrosão por parte da liga AWS ERNiCrMo-14 em relação às demais ligas.
17

Estudo de Propriedades Químicas e Físicas de Revestimentos de Ni-Mo, Ni-W e Ni-Mo-W / Study of Chemical and Physical Properties of Ni -Mo coatings , Ni -W and Ni -Mo- W

Casciano, Paulo Naftali da Silva January 2014 (has links)
CASCIANO, Paulo Naftali da Silva. Estudo de Propriedades Químicas e Físicas de Revestimentos de Ni-Mo, Ni-W e Ni-Mo-W. 2014. 143 f. Tese (Doutorado em química)-Universidade Federal do Ceará, Fortaleza-CE, 2014. / Submitted by Elineudson Ribeiro (elineudsonr@gmail.com) on 2016-06-02T20:10:02Z No. of bitstreams: 1 2014_tese_pnscasciano.pdf: 5142047 bytes, checksum: f52b27fdaa105e9f7927bd0ad39461c0 (MD5) / Approved for entry into archive by José Jairo Viana de Sousa (jairo@ufc.br) on 2016-07-20T20:07:37Z (GMT) No. of bitstreams: 1 2014_tese_pnscasciano.pdf: 5142047 bytes, checksum: f52b27fdaa105e9f7927bd0ad39461c0 (MD5) / Made available in DSpace on 2016-07-20T20:07:37Z (GMT). No. of bitstreams: 1 2014_tese_pnscasciano.pdf: 5142047 bytes, checksum: f52b27fdaa105e9f7927bd0ad39461c0 (MD5) Previous issue date: 2014 / The present study aimed to characterise the coatings Ni, Ni-Mo, Ni-W and Ni-Mo-W obtained at 30 mA cm–2 and 60 mA cm–2 from electrolyte containing H3BO3, (NH4)2SO4, CH3(CH2)10CH2OSO3Na, Na3C6H5O7.2H2O, NiSO4.2H2O, Na2MoO4.2H2O, Na2WO4.2H2O in pH 10. The composition of the coatings was obtained by energy dispersive X-ray, with the maximum percentage of Mo and W in the coating being equal to 28 % and 7%, respectively. Results of EDX indicated that deposition control of the W was for activation, whereas the kinetics of electrodeposition Mo was controlled by diffusion. Analisys by scanning electron microscopy showed that the coating obtained were nodular and homogeneous. The coatings obtained at 30 mA cm–2 showed a decrease in the crystallite size of 28.4 nm to 3.2 nm, with increasing Mo + W percentage from 0% to 29%. The coatings obtained at 60 mA cm–2 showed larger crystallite size in coatings with similar composition. Increases from 0% to 26% on percentage of Mo + W caused decrease in crystallite size from 39.3 nm to 4.3 nm. The higher microhardness values were obtained with decreasing crystallite. Corrosion resistance of the coatings was performed by linear potentiodynamic polarization curves and electrochemical impedance spectroscopy in 0.1 mol dm–3 NaCl and 0.1 mol dm–3 H2SO4 solutions. In 0.1 mol dm–3 NaCl solution, it was observed that the increase of the percentage Mo + W from 0 % to 29% shifted the corrosion potential to more negative values, from –0.64 V to –0.79 V. Higher percentage of molybdenium in coatings originated more protective passivation films. In acidic medium, Ni and Ni-W coatings showed dissolution at the analysis carried out by polarization curves, while for the Ni-Mo and Ni-Mo-W coatings passivation currents was observed. Local pH measurements during the polarization curves in neutral medium shown the possibility of formation of oxides and/or hydroxides in the passivation film. Impedance spectra performed, regardless of the corrosive medium, showed two or three time constants corroborating the formation of oxides and/or hydroxides on the surface coatings of Ni-Mo, Ni-Mo and Ni-MoW. Coatings Ni-Mo-W showed better characteristics for corrosion resistance than Ni-W. / Este trabalho teve como objetivo caracterizar química e fisicamente revestimentos de Ni, Ni-Mo, Ni-W, Ni-Mo-W obtidos em 30 mA cm–2 e 60 mA cm–2 a partir de soluções eletrolíticas contendo H3BO3, (NH4)2SO4, CH3(CH2)10CH2OSO3Na, Na3C6H5O7.2H2O, NiSO4.2H2O, Na2MoO4.2H2O e Na2WO4.2H2O em pH 10. A composição dos revestimentos foi obtida por Energia Dispersiva de Raios-X (EDX), com a porcentagem de Mo de W no revestimento atingindo valores máximos de 28% e de 7%, respectivamente. O resultado de EDX indicou que o controle de deposição do W foi por ativação, enquanto que a cinética de eletrodeposição do Mo foi controlada por difusão. Análises por Microscopia Eletrônica de Varredura (MEV) mostraram que os revestimento obtidos foram homogêneos e nodulares. Os revestimentos obtidos a 30 mA cm–2 apresentaram decréscimo no tamanho de cristalito de 28,4 nm para 3,2 nm, com o aumento das porcentagens de Mo+W de 0% para 29%. Os revestimentos obtidos a 60 mA cm–2 apresentaram maiores tamanhos de cristaitos para revestimentos com mesma composição. Um aumento de 0% para 26% na porcentagem de Mo+W provocou decréscimo no tamanho de cristalito de 39,3 nm para 4,3 nm. Maiores valores de microdureza foram obtidos com o decréscimo do cristalito. A avaliação dos revestimentos quanto à resistência à corrosão foi executada por meio de curvas de polarização potenciodinâmica linear e espectroscopia de impedância eletroquímica em soluções de NaCl 0,1 mol dm–3 e H2SO4 0,1 mol dm–3. Em solução de NaCl 0,1 mol dm–3, observou-se que o aumento da pocentagem de Mo+W de 0% para 29% deslocou o potencial de corrosão para valores mais negativos, de –0,64 V para –0,79 V. Uma maior porcentagem de molibdênio no revestimento favoreceu a formação de filmes de passivação mais protetores. As análises em meio ácido, realizadas por meio das curvas de polarização, mostraram a dissolução do revestimento de Ni e Ni-W, enquanto que para os revestimentos Ni-Mo e Ni-Mo-W foi observada corrente de passivação. Medidas de pH local durante as curvas de polarização em meio neutro revelaram a possibilidade de formação de óxidos e/ou hidróxidos nos filmes de passivação. Os espectros de impedância realizados, independente do meio corrosivo, mostraram duas ou três constantes de tempo corroborando a formação de óxidos e/ou hidróxidos sobre a superfície dos revestimentos de Ni-Mo, Ni-Mo e Ni-Mo-W. Entre os revestimentos, Ni-W apresentou resultados menos interessantes quanto à resistência à corrosão com o tempo de imersão. Os revestimentos de Ni-Mo-W apresentaram melhores características relativas à resistência à corrosão.
18

Estudo da corrosão naftênica por espectrometria de massas de altíssima resolução e exatidão (ESI –FT-ICR MS) & microscopia de força atômica

Dias, Heloisa Pinto 11 December 2014 (has links)
Submitted by Elizabete Silva (elizabete.silva@ufes.br) on 2015-10-13T20:15:06Z No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Estudo da corrosão naftênica por espectrometria de massas.pdf: 10701056 bytes, checksum: 7912e39576c3f3d1c9b91b6618a7c1b5 (MD5) / Approved for entry into archive by Patricia Barros (patricia.barros@ufes.br) on 2015-11-17T11:00:49Z (GMT) No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Estudo da corrosão naftênica por espectrometria de massas.pdf: 10701056 bytes, checksum: 7912e39576c3f3d1c9b91b6618a7c1b5 (MD5) / Made available in DSpace on 2015-11-17T11:00:49Z (GMT). No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Estudo da corrosão naftênica por espectrometria de massas.pdf: 10701056 bytes, checksum: 7912e39576c3f3d1c9b91b6618a7c1b5 (MD5) Previous issue date: 2014 / Capes / Os ácidos naftênicos são considerados os principais responsáveis pela corrosão no processo de refino do petróleo, e se não for devidamente monitorada, a corrosão naftênica pode causar graves prejuízos para a indústria petroquímica. No primeiro capítulo deste trabalho duas amostras de petróleo, tratadas a 300°C/2h e 350°C/6h, foram postas em contato com aço carbono AISI 1020 durante 15 dias. A acidez do óleo original e dos produtos oriundos do tratamento térmico foi monitorada por número de acidez total (NAT), espectrometria de massas de altíssima resolução e exatidão (ESI(-)- FT-ICR) e a corrosão no aço foi monitorada por microsospia de força atômica (AFM). Os dados de ESI(-)-FT-ICR MS mostraram que na classe O2, as principais espécies majoritárias detectadas foram de número de carbono C25-C32 e DBE = 3. Para o tratamento a 350ºC/6h, observou-se uma redução de ~ 80% no NAT. Os resultados obtidos por AFM mostraram que a topografia da superfície do aço exposto ao óleo tratado a 300°C/2h possui efeitos mais pronunciados de corrosão, pois, o padrão de rugosidade medido pela "altura de pico a pico" da superfície, indicou que a superfície exposta ao óleo 300°C/2h, embora apresente uma série de irregularidades é menos pronunciada, que a superfície do aço exposto ao óleo tratado a 350°C/6h. No segundo capítulo, dois petróleos com acidez distinta, J e G, foram caracterizados por ESI (-) - FT-ICR MS. O aço AISI 316 foi analisado por microscopia ótica, microscopia de força atômica e por espectroscopia Raman. Os resultados mostraram que as principais classes identificadas nas amostras foram as classes O2 e N2. Em relação à classe O2, as principais espécies majoritárias detectadas foram de número de carbono C24-C35 e DBE= 3 e C29-C35 e DBE= 4. As imagens de AFM revelaram que para o intervalo de 14 dias, o aço exposto ao óleo J, apresentou fortes alterações topográficas em relação ao branco,caracterizando o início do processo corrosivo. Essas informações são compatíveis com os espectros de Raman, em que para este intervalo de tempo foram evidenciados a formação de Goetita, Magnetita e Hematita. As alterações topográficas para o aço exposto ao petróleo G, só puderam ser observadas após 21 dias de análise por AFM. No terceiro capítulo, uma amostra de petróleo foi tratada termicamente, na presença e ausência de catalisador, a 300 e 350 ºC pelo período de 2, 4 e 6 horas. A acidez do petróleo original e dos produtos oriundos do tratamento térmico com catalisador foi determinada pelo NAT. A variação do conteúdo de polares nas amostras, em especial a classe O2, foi monitorada por ESI (-)-FT-ICR MS. De uma maneira geral, as principais classes identificadas para ambas às amostras foram O2, N e NO2, respectivamente. Em relação à classe O2 correspondente aos ácidos naftênicos, as principais espécies majoritárias foram de C25-C32 e DBE = 4. Observou-se uma redução de 43,50% no petróleo degradado á 350°C durante 4h na presença do catalisador evidenciando assim a eficiência da remoção dos ácidos naftênicos nas condições avaliadas. / Naphthenic acids are considered primarily responsible for corrosion in the oil refining process, and if not properly monitored, the naphthenic corrosion can cause severe damage to the petrochemical industry. In the first chapter of this work, two oil samples treated at 300°C/2h 350°C/6h, were brought in contact with carbon steel AISI 1020 for 15 days. The acidity of the original and products from oil heat treatment was monitored by TAN ESI (-) - FT-ICR-MS and corrosion on steel was monitored by AFM. The ESI (-) - FT-ICR MS showed that the O2 class, the major species detected were majority carbon number of C25-C32 and DBE = 3. For treatment at 350°C/6h, there was a reduction of ~ 80% in the TAN. The results showed that AFM topography of the steel surface exposed to the oil treated at 300°C/2h has higher effects of corrosion, since the pattern of roughness measured by "peak to peak height" of the surface, indicated that the surface exposed to the oil 300°C/ 2h, although it presents a number of irregularities is less pronounced, the surface exposed to the oil-treated steel at 350°C/6h. In the second chapter, two oils with different J and G acidity were characterized by ESI (-) - FT-ICR MS. The AISI 316 steel was analyzed by optical microscopy, atomic force microscopy and Raman spectroscopy. The results showed that the major classes were identified in the samples classes O2 and N2. Regarding O2 class, the major species detected were majority of carbon number C24 and C35 = 3 DBE and DBE and C29-C35 = 4. The AFM images showed that the interval for 14 days, the steel exposed to oil J, showed strong topographic changes from white, characterizing the onset of the corrosion process. This information is consistent with the Raman spectra that for this period of time the formation of goethite, hematite and magnetite were evidenced. Topographical changes to the exposed steel to oil G could only be observed after 21 days of analysis by AFM. The third chapter, a sample oil was thermally treated in the presence and absence of catalyst at 300 and 350 ° C for a period of 2, 4 and 6 hours. The acidity of the original oil and products derived from thermally treated catalyst was determined by TAN. The variation in the content of polar samples, particularly class O2 was monitored by ESI (-) - FT-ICR MS. Generally, the major classes identified for both samples were N, NO2, and O2, respectively. Regarding O2 class corresponding to naphthenic acids, the major species were majority of C25-C32 and DBE = 3. There was a 43.50% reduction in the degraded oil at 350°C for 4h in the presence of the catalyst thus demonstrating the efficiency of removal of naphthenic acids under the conditions evaluated.
19

Avaliação eletroquimica de revestimentos inorganicos depositados fisicamente sobre a liga Fe-1,5% Mo sinterizada

Alves Neto, Jose de Pinho January 1996 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnologico / Made available in DSpace on 2016-01-08T21:15:12Z (GMT). No. of bitstreams: 1 106523.pdf: 22823662 bytes, checksum: e91a02170ece59a2cebae03f3e21c7ec (MD5) Previous issue date: 1996 / A utilização de peças sinterizadas tem crescido muito nas últimas décadas em função de algumas vantagens como economia de matéria-prima e custos baixos de produção. Mas devido a porosidade residual decorrente do processo de produção, os materiais sinterizados apresentam baixa resistência ao desgaste químico. Neste trabalho avaliou-se a utilização de tratamentos superficiais como nitretação por plasma e deposição de titânio via ?magnetron sputtering?. Concluiu-se que ambos os tratamentos são viáveis, e que a temperatura de nitretação e o tempo de deposição do titânio são fatores importantes para o aumento da resistência à corrosão dos materiais sinterizados.
20

Análise do efeito de inibidores de corrosão em compósito cimentício reforçado com aço empregando ensaios eletroquímicos

Trevisol, César Augusto Madeira January 2014 (has links)
Dissertação de Mestrado apresentada ao Programa de Pós-Graduação em Ciência e Engenharia de Materiais da Universidade do Extremo Sul Catarinense - UNESC, como requisito à obtenção do título de Mestre em Ciência e Engenharia de Materiais. / As maiores densidades demográficas no Brasil estão situadas no litoral onde, consequentemente, tem-se o maior número de edificações. Estas edificações estão sujeitas à corrosão pela migração de íons cloreto, que levam à deterioração das estruturas de concreto armado. Para oferecer maior segurança e durabilidade às estruturas estão disponíveis no mercado algumas formas de proteção, para os mais diversos tipos de ataques corrosivos. O estudo do desempenho de aditivos inibidores de corrosão para proteção de estruturas de concreto armado é de fundamental importância para garantir a durabilidade e a redução de gastos com manutenções e recuperações. Desta forma, este trabalho apresenta resultados de um estudo microestrutural (por microscopia eletrônica de varredura (MEV) e microscopia ótica (MO)) e eletroquímico (por medidas de potencial e de resistência à polarização linear (LPR)) em amostras de argamassa armada. Foram avaliados três tipos de aditivos – um comercial à base de sais de nitrito (DCI), tungstato de sódio (T) e molibdato de sódio (M) – nas idades de 60 (DCI), 75 e 90 dias (DCI, T, M) em duas concentrações de aditivos mais a composição de referência. As amostras foram moldadas no formato cilíndrico (50 x 100 mm²) e reforçadas com aço CA 50 (8 mm) no centro, sendo expostas a duas formas distintas de indução e aceleração da corrosão: com o uso do potenciostato e por meio de ciclos de imersão parcial em solução de 3,5% NaCl, com posterior secagem em estufa. Pela técnica de resistência à polarização linear foi possível avaliar a taxa de corrosão estimada para as amostras. A análise dos resultados mostrou que o molibdato de sódio apresentou um desempenho melhor que os demais. Pode-se constatar que a indução da corrosão ocorreu com sucesso. Desta forma, conclui-se que os aditivos contribuíram para a redução das taxas de corrosão, porém a idade e a cura tiveram uma influência significativa nas taxas de corrosão obtidas.

Page generated in 0.0599 seconds