• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 10
  • 7
  • 2
  • 1
  • Tagged with
  • 19
  • 19
  • 7
  • 7
  • 7
  • 7
  • 6
  • 5
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Leva med livvakt : personers upplevelser av att leva med implanterbar defibrillator / Living with a bodyguard : persons' experiences of living with an implantable cardioverter defibrillator

Hellkvist, Karin, Wallebom, Terhi January 2020 (has links)
Personer som överlevt hjärtstopp, eller som löper stor risk att drabbas av allvarlig ventrikulär arytmi, kan skyddas mot framtida livshotande arytmier med en implanterbar defibrillator (ICD). För att bryta kammartakykardier kan ICD:n avge högvoltschocker från en elektrod i höger kammare. Chockerna upplevs av många som smärtsamma. Många personer som fått en ICD implanterad beskriver ökad oro och ångest. Syftet var att belysa personers upplevelser och erfarenheter av att leva med ICD. Som metod valdes litteraturöversikt. Efter sökning i databaserna PubMed och CINAHL inkluderades 15 kvalitativa intervjustudier publicerade 2009-2018. Dessa analyserades utifrån kvalitativ innehållsanalys och resulterade i fyra kategorier; Ett oförutsägbart liv, Ett förändrat liv, Vägen framåt och Trygg trots allt. Dessa kan beskrivas som steg i en trappa. Resultatet i denna litteraturöversikt visade att många beskrev den första tiden efter ICDimplantationen som svår, med smärtor, oro och depression. Livet beskrevs ha blivit förändrat och rädsla för ICD-chocker upplevdes ha stor påverkan i det dagliga livet. Genom självpåtagna begränsningar försökte personerna kontrollera sin situation för att förebygga chocker. De flesta kunde efter en tid acceptera ICD-behandlingen som en del av livet och anpassade sig till situationen. Kategorin Trygg trots allt var inte ett konstant tillstånd, då en upplevd ICD-chock kunde rasera tryggheten och föra processen bakåt. Slutsatsen var att det mesta som berättades berörde chocken, hur den kändes, rädsla för chock, vad som kan utlösa en chock och hur den kan undvikas. ICD-chocken blev något som berörde varje aspekt av livet. Ändå fann många en ny balans där ICD:n blev en del av livet och accepterades som en livvakt. Stöd från vårdpersonal var viktigt för att uppleva trygghet, men ett personcentrerat stöd behöver utvecklas. / Persons who survived sudden cardiac arrest or who are at risk for severe ventricular arrythmias, can be protected from future life-threatening arrythmias by an implantable cardioverter defibrillator (ICD). To terminate ventricular arrythmias, the ICD can deliver high-voltage shocks from an electrode placed in the right ventricle. The shocks are by most people felt to be painful. Many persons who have an ICD implanted, experience increased anxiety and distress. The aim if the study was to illustrate persons’ experiences of living with an ICD The chosen method was a literature review. After searching the databases PubMed and CINAHL, 15 qualitative interview studies, published between 2009 and 2019, were included. These were analyzed with qualitative content analysis and resulted in four categories; An unpredictable life, A changed life, The road ahead and Safe anyway. These categories can be described as four steps. The result of this literature review showed that many described the first period after ICD implantation as difficult, including pain, anxiety and depression. Life was experienced to have changed and fear of ICD-shocks was considered to have great impact on daily life. Through self-imposed restrictions the persons tried to control their situation to prevent shocks. Most persons could by time accept the ICD-treatment as a part of life and adjusted to the situation. The level Safe anyway was not a constant condition as an experience of shock diminished safety and brought the process backward. The conclusion was that most what was narrated concerned the shock, what it felt like, fear of shock, what might trigger a shock and how to avoid it. The ICD shock was something that affected every aspect of life. Still many found a new balance in life where the ICD became an important part of life and was accepted as a body guard. Support from health professionals was important to experience safety but a person-centered support needs to be developed.
12

Qualidade e capacidade diagnóstica da imagem de ressonância magnética cardíaca de 1,5 Tesla em pacientes com cardioversor desfibrilador implantável condicional / Quality and diagnostic capacity of the 1.5 Tesla magnetic resonance imaging in patients with conditional implantable cardioverter defibrillator

Andrade, Veridiana Silva de 28 May 2019 (has links)
Introdução: A realização do exame de ressonância magnética (RM), classicamente contraindicada aos portadores de dispositivo cardíaco eletrônico implantável (DCEI), passou a ser factível com a introdução dos recentes dispositivos condicionais para RM. Estes demonstraram superior grau de segurança na realização da RM, mas pouco se sabe sobre a qualidade e a capacidade diagnóstica das imagens obtidas no exame. Estas podem ser distorcidas pela presença do DCEI, sobretudo no que se refere ao cardioversor desfibrilador implantável (CDI), cuja quantidade de material ferromagnético é relevante. Objetivo: avaliar a qualidade e a capacidade diagnóstica da imagem de da RM cardíaca de 1,5 Tesla em portadores de CDI condicional. Método: Estudo piloto incluindo portadores de CDI condicional submetidos a RMC prévia (RMC1). Todos os pacientes realizaram exame de RMC pós-implante (RMC2), com protocolo específico de sequências de pulso utilizadas para cineressonância, realce tardio, perfusão miocárdica, mapa T1, mapa de fluxo, avaliação anatômica e de edema miocárdico. Todos foram submetidos à avaliação eletrônica do CDI, pré e pós RMC2, que constou de: medida do limiar de estimulação e sensibilidade, da impedância dos cabos-eletrodo e de choque, assim como da carga da bateria. Três especialistas avaliaram a qualidade das imagens de RMC, pré e pós-implante do CDI, que foram pontuadas por Escala de Likert. Esta gradua de 1 a 5 o impacto do artefato de imagem e a capacidade diagnóstica do exame. Para as imagens obtidas por múltiplos cortes a mesma pontuação foi utilizada para cada segmento do VE (segmentação da American Heart Association - AHA). A capacidade diagnóstica foi expressa, em percentual, pela taxa diagnóstica (sendo considerada diagnóstica pontuação maior ou igual a 3). Resultados: Foram estudados 22 pacientes submetidos a implante CDI condicional no período de agosto/2016 a abril/2018. Todas as imagens da RMC1 tiveram alta pontuação (3 a 5, m= 4,7) na escala de Likert. Por outro lado, em todos os exames da RMC2 ocorreram artefatos de suscetibilidade, sendo que as paredes anterior e lateral do VE foram mais afetadas. A pontuação média segmentar e respectivas taxas de imagens diagnósticas foram: 3,1 pontos e 82,32% para CINE SSFP; 1,74 e 27,80% para RT; 2,08 e 30,4% para perfusão miocárdica. As taxas de imagens diagnósticas obtidas nas aquisições por corte único foram: 0% para o mapa T1; 77,3% para avaliação anatômica (double e triple anatômico); 68,2% mapa de fluxo e 9,0% para avaliação do edema. Conclusão: Em portadores de CDI condicional, a qualidade das imagens e a capacidade diagnóstica do exame de RMC estão comprometidas por artefatos de suscetibilidade, presentes, sobretudo, nas paredes anterior e lateral de VE. Em particular a técnica de realce tardio, uma das mais importantes na RMC para diagnóstico de cardiomiopatias, demonstrou reduzida taxa diagnóstica, apontando a necessidade de novas técnicas para a detecção de fibrose/lesão miocárdica pela RMC. De forma geral, esses achados sugerem que é necessário realizar investigações adicionais, visando otimizar qualidade de imagem e capacidade diagnóstica da RMC nos portadores de CDI condicional / Introduction: Magnetic resonance imaging (MRI), which is classically contraindicated in patients with cardiac implantable electronic device (CIED), became feasible with the introduction of the recent MRI conditional devices. These have been proven to be safer, but little is known about the quality and diagnostic capacity of the acquired images, which can be distorted by the presence of CIED, especially with regard to the implantable cardioverter defibrillator (ICD), whose quantity of ferromagnetic material is relevant. Objective: to evaluate the quality and diagnostic value of the images acquired by cardiac MR in patients with conditional ICD. Method: Pilot study of patients with MR conditional ICD who were submitted to previous CMR (CMR1). All patients underwent an another CMR after ICD implantation (CMR2), under specific protocol of pulse sequences used for cine-resonance, late enhancement, myocardial perfusion, T1 mapping, anatomic and myocardial edema evaluation, and flow map. All patients underwent ICD electronic interrogations, immediate pre and post CMR2 measurements of battery voltage, capture thresholds, sensing, lead and shock impedance. Three specialists evaluated the quality of CMR images, pre and post implantation of ICD, which were scored by the Likert Scale. This graded measure from 1 to 5 the impact of the imaging artifact and the diagnostic ability of the examination. For the images acquired by multiple slices the same score was used for each left ventricule (LV) segment (American Heart Association - AHA criteria). Results: We studied 22 patients submitted to MR conditional ICD implantation. CMR1 had a high score (3 to 5, m = 4.7) on the Likert scale. On the other hand, in all CMR2 exams, there were artifacts of susceptibility, and the anterior and lateral LV walls were more affected. The mean segmental score and respective diagnostic image rates were: 3.1 points and 82.32% for Cine SSFP; 1.74 and 27.80% for LGE; 2.08 and 30,4% for myocardial perfusion. The rates of diagnostic images obtained in the single slice acquisition were 0% for T1 mapping; 77.3% for anatomical evaluation (double and triple anatomic); 68.2% for flow map and 9.0% for myocardial edema evaluation. Conclusion: In patients with MR conditional ICD, the quality of the images and the diagnostic capacity of the CMR examination are compromised by susceptibility artifacts, present mainly in the anterior and lateral LV walls. These findings suggest that further research is needed to optimize image quality and diagnostic capacity of CMR in patients with MR conditional ICD
13

Perfil psicossocial de portadores de CDI: COMFORT-CDI / Psychosocial profile of patients: COMFORT-ICD

Guimarães, Tathiane Barbosa 08 August 2016 (has links)
Introdução: Ansiedade, depressão, personalidade Tipo D e terapias de choque do cardioversor-desfibrilador implantável (CDI) são fatores de risco para pior ajuste psicossocial. Além da maior parte dos estudos serem realizados em países desenvolvidos, pouca atenção é dada a estes e outros fatores, assim como à influência na percepção de portadores de CDI quanto à sua cardiopatia de base. Estratégias de enfrentamento, diferença entre percepção do CDI e da doença, assim como percepção dos familiares também têm sido negligenciadas. Os objetivos deste estudo foram descrever o perfil psicossocial de portadores de CDI em nosso meio, avaliar a relação entre os fatores de risco supracitados, percepções do paciente quanto à doença cardíaca e CDI, a relação entre ocorrência e frequência das terapias de choque do CDI e a compreensão e percepção de familiares em relação ao CDI. Método: 250 portadores de CDI foram avaliados (54.10 ±15.15 anos, 67% sexo masculino) quanto à percepção de doença (Questionário Breve de Percepção de Doença [B-IPQ]); ansiedade, depressão, distress (Escala Hospitalar de Ansiedade e Depressão [HADS]); personalidade Tipo D (DS-14); ocorrência e frequência de choques do CDI desde implante e estratégias de enfrentamento. Representações emocionais e compressão de familiares dos pacientes também foram medidas. A análise estatística utilizou os métodos de Mann-Whitney, Wilcoxon e X2. Resultados: Noventa e nove pacientes (39,6%) apresentaram ansiedade, 62 (24.8%) depressão; 85(34%) distress, 84(34%) personalidade Tipo D e 72(29%) perceberam a doença cardíaca como ameaça. Ansiedade, distress, depressão e personalidade Tipo D foram associadas à percepção de cardiopatia como ameaçadora, OR=11 (p= <. 0001); 7.4 (p= <. 0001); 5.3 p= <. 0001); e 2.9 (p= 0.0001), respectivamente. A percepção da doença cardíaca como ameaça também foi influenciada pela presença de choques do CDI desde o implante, com OR= 2.2 (p= 0.007), 2.1 para >=3 choques em 24 horas (p= 0.03) e 2.4 para >= 5 choques desde o implante (p= 0.008). Pacientes ansiosos e Tipo D foram associados a pior percepção de doença, considerando: 1 - fortes crenças sobre consequências mais graves da doença; 2 - não serem capazes de controlar a doença; 3 - atribuem maior número de sintomas à doença; 4 - são mais preocupados e apresentam mais emoções negativas. As percepções de pacientes com distress ou depressivos são mais negativas em todas as subescalas, exceto compreensão. A maioria dos pacientes (68%) utilizou estratégias de enfrentamento focadas na emoção. Vinte e cinco por cento dos pacientes reportaram limitação imposta pela doença, enquanto 75% se sentiram limitados pelo CDI. Pacientes perceberam mais consequências negativas da doença que do CDI. Familiares apresentaram desgaste emocional e baixa compreensão quanto o uso e funcionamento do CDI. Conclusões: Portadores de CDI assistidos em hospital terciário de atenção cardiológica apresentaram: Elevada taxa de ocorrência de ansiedade; depressão, distress, personalidade Tipo D e percepção de doença como ameaça; Limitação das atividades da vida diária como a maior demanda vivenciada; Cardiopatia de base afetando mais a vida que o CDI, mas a maioria considerando o choque do CDI aversivo. Implicação: Intervenções psicossociais específicas são essenciais para melhor ajustamento de portadores de CDI e seus familiares / Introduction: Anxiety, depression, Type D personality, and implantable cardioverter-defibrillator (ICD) shocks are well-known risk factors for psychosocial maladjustment. Despite the fact that most of the studies were conducted in well-developed countries, little attention has been given to these and others factors and their influence on ICD patients\' perceptions of their heart disease. Coping strategies, the differences between ICD patient and heart disease patient perceptions, and the perception of family members has also been neglected. This project was aimed at describing the psychosocial profile of Brazilian ICD patients and evaluating the relationship between the aforementioned risk factors and patient perceptions about their heart disease and ICD, the temporal relation between occurrence and frequency of ICD shocks, and the understanding and perception of family members regarding the ICD. Methods: 250 ICD patients were evaluated (54.10 ±15.15 years, 67% male) regarding illness perception (Brief Illness Perception Questionnaire [B-IPQ]); anxiety, depression, distress (Hospital Anxiety and Depression Scale [HADS]); Type D personality (DS-14); occurrence and frequency of ICD shocks since implantation; and coping. Family members\' comprehension and emotional representations of the ICD were also assessed. Mann-Whitney, Wilcoxon and X2 were used for statistical analysis. Results: Ninety-nine patients (40%) had anxiety, 62 (25%) depression; 85 (34%) distress, 84 (34%) Type D personality, and 72 (29%) perceived the heart disease as a threat. Anxiety, distress, depression, and Type D personality were associated with perceiving heart disease as a health threat with odds ratios of 11 (p= <.0001); 7.4 (p= <.0001); 5.3 (p= <.0001); and 2.9 (p= 0.0001), respectively. Patients\' perceptions of their heart disease as a threat were also influenced by ICD shocks since implantation with odds ratios of 2.1 (p= 0.007), of 2.1 for >=3 shocks in 24 hours (p= 0.045) and of 2.4 for >= 5 shocks since implantation (p= 0.043). Anxious and Type D patients were also associated with poorer illness perceptions regarding: 1 - strong beliefs about more serious consequences of the illness; 2 - not being capable of controlling the disease on their own; 3 - a greater number of symptoms attributed to the illness; 4 - more concerns and negative reactions. Distressed or depressive patients\' perceptions are more negative on every item of the scale except for understanding. The majority of patients (68%) used emotion focused coping mechanisms. Twenty-five percent of the patients reported feeling limited by heart disease, while 75% reported feeling limited by having the ICD in place. Patients perceived more negative consequences with heart disease than with ICD placement. Family members manifested distress about the ICD and misunderstanding regarding its purpose and function. Conclusions: ICD patients treated in a tertiary heart center presented with incresead frequency of anxiety, depression, distress, Type D personality, and perception of their illness as threat. Limitation of activities of daily living was the most common complaint. Heart disease was reported as more debilitating than the ICD itself, but most patients still considered the device\'s shock aversive. Implication: Specific psychosocial interventions are essential for better adjustment of ICD patients and their families after ICD placement
14

Perfil psicossocial de portadores de CDI: COMFORT-CDI / Psychosocial profile of patients: COMFORT-ICD

Tathiane Barbosa Guimarães 08 August 2016 (has links)
Introdução: Ansiedade, depressão, personalidade Tipo D e terapias de choque do cardioversor-desfibrilador implantável (CDI) são fatores de risco para pior ajuste psicossocial. Além da maior parte dos estudos serem realizados em países desenvolvidos, pouca atenção é dada a estes e outros fatores, assim como à influência na percepção de portadores de CDI quanto à sua cardiopatia de base. Estratégias de enfrentamento, diferença entre percepção do CDI e da doença, assim como percepção dos familiares também têm sido negligenciadas. Os objetivos deste estudo foram descrever o perfil psicossocial de portadores de CDI em nosso meio, avaliar a relação entre os fatores de risco supracitados, percepções do paciente quanto à doença cardíaca e CDI, a relação entre ocorrência e frequência das terapias de choque do CDI e a compreensão e percepção de familiares em relação ao CDI. Método: 250 portadores de CDI foram avaliados (54.10 ±15.15 anos, 67% sexo masculino) quanto à percepção de doença (Questionário Breve de Percepção de Doença [B-IPQ]); ansiedade, depressão, distress (Escala Hospitalar de Ansiedade e Depressão [HADS]); personalidade Tipo D (DS-14); ocorrência e frequência de choques do CDI desde implante e estratégias de enfrentamento. Representações emocionais e compressão de familiares dos pacientes também foram medidas. A análise estatística utilizou os métodos de Mann-Whitney, Wilcoxon e X2. Resultados: Noventa e nove pacientes (39,6%) apresentaram ansiedade, 62 (24.8%) depressão; 85(34%) distress, 84(34%) personalidade Tipo D e 72(29%) perceberam a doença cardíaca como ameaça. Ansiedade, distress, depressão e personalidade Tipo D foram associadas à percepção de cardiopatia como ameaçadora, OR=11 (p= <. 0001); 7.4 (p= <. 0001); 5.3 p= <. 0001); e 2.9 (p= 0.0001), respectivamente. A percepção da doença cardíaca como ameaça também foi influenciada pela presença de choques do CDI desde o implante, com OR= 2.2 (p= 0.007), 2.1 para >=3 choques em 24 horas (p= 0.03) e 2.4 para >= 5 choques desde o implante (p= 0.008). Pacientes ansiosos e Tipo D foram associados a pior percepção de doença, considerando: 1 - fortes crenças sobre consequências mais graves da doença; 2 - não serem capazes de controlar a doença; 3 - atribuem maior número de sintomas à doença; 4 - são mais preocupados e apresentam mais emoções negativas. As percepções de pacientes com distress ou depressivos são mais negativas em todas as subescalas, exceto compreensão. A maioria dos pacientes (68%) utilizou estratégias de enfrentamento focadas na emoção. Vinte e cinco por cento dos pacientes reportaram limitação imposta pela doença, enquanto 75% se sentiram limitados pelo CDI. Pacientes perceberam mais consequências negativas da doença que do CDI. Familiares apresentaram desgaste emocional e baixa compreensão quanto o uso e funcionamento do CDI. Conclusões: Portadores de CDI assistidos em hospital terciário de atenção cardiológica apresentaram: Elevada taxa de ocorrência de ansiedade; depressão, distress, personalidade Tipo D e percepção de doença como ameaça; Limitação das atividades da vida diária como a maior demanda vivenciada; Cardiopatia de base afetando mais a vida que o CDI, mas a maioria considerando o choque do CDI aversivo. Implicação: Intervenções psicossociais específicas são essenciais para melhor ajustamento de portadores de CDI e seus familiares / Introduction: Anxiety, depression, Type D personality, and implantable cardioverter-defibrillator (ICD) shocks are well-known risk factors for psychosocial maladjustment. Despite the fact that most of the studies were conducted in well-developed countries, little attention has been given to these and others factors and their influence on ICD patients\' perceptions of their heart disease. Coping strategies, the differences between ICD patient and heart disease patient perceptions, and the perception of family members has also been neglected. This project was aimed at describing the psychosocial profile of Brazilian ICD patients and evaluating the relationship between the aforementioned risk factors and patient perceptions about their heart disease and ICD, the temporal relation between occurrence and frequency of ICD shocks, and the understanding and perception of family members regarding the ICD. Methods: 250 ICD patients were evaluated (54.10 ±15.15 years, 67% male) regarding illness perception (Brief Illness Perception Questionnaire [B-IPQ]); anxiety, depression, distress (Hospital Anxiety and Depression Scale [HADS]); Type D personality (DS-14); occurrence and frequency of ICD shocks since implantation; and coping. Family members\' comprehension and emotional representations of the ICD were also assessed. Mann-Whitney, Wilcoxon and X2 were used for statistical analysis. Results: Ninety-nine patients (40%) had anxiety, 62 (25%) depression; 85 (34%) distress, 84 (34%) Type D personality, and 72 (29%) perceived the heart disease as a threat. Anxiety, distress, depression, and Type D personality were associated with perceiving heart disease as a health threat with odds ratios of 11 (p= <.0001); 7.4 (p= <.0001); 5.3 (p= <.0001); and 2.9 (p= 0.0001), respectively. Patients\' perceptions of their heart disease as a threat were also influenced by ICD shocks since implantation with odds ratios of 2.1 (p= 0.007), of 2.1 for >=3 shocks in 24 hours (p= 0.045) and of 2.4 for >= 5 shocks since implantation (p= 0.043). Anxious and Type D patients were also associated with poorer illness perceptions regarding: 1 - strong beliefs about more serious consequences of the illness; 2 - not being capable of controlling the disease on their own; 3 - a greater number of symptoms attributed to the illness; 4 - more concerns and negative reactions. Distressed or depressive patients\' perceptions are more negative on every item of the scale except for understanding. The majority of patients (68%) used emotion focused coping mechanisms. Twenty-five percent of the patients reported feeling limited by heart disease, while 75% reported feeling limited by having the ICD in place. Patients perceived more negative consequences with heart disease than with ICD placement. Family members manifested distress about the ICD and misunderstanding regarding its purpose and function. Conclusions: ICD patients treated in a tertiary heart center presented with incresead frequency of anxiety, depression, distress, Type D personality, and perception of their illness as threat. Limitation of activities of daily living was the most common complaint. Heart disease was reported as more debilitating than the ICD itself, but most patients still considered the device\'s shock aversive. Implication: Specific psychosocial interventions are essential for better adjustment of ICD patients and their families after ICD placement
15

"Cardiomiopatia hipertrófica: importância dos eventos arrítmicos em pacientes com risco de morte súbita" / Hypertrophic cardiomyopathy: sudden cardiac death in high risk patients and the role of arrhythmias

Medeiros, Paulo de Tarso Jorge 10 December 2004 (has links)
Vinte e seis pacientes com cardiomiopatia hipertrófica e fatores de risco de morte súbita, foram submetidos a implante de cardioversor-desfibrilador implantável de dupla-câmara, com seguimento médio de 19 meses. Observou-se quatro choques em arritmias letais, 4 pacientes apresentaram TVNS e 5 taquiarritmias supraventriculares. Ocorreu um óbito.Conclusões: Observamos: TPSV em 19,2%; TVNS em 15,4% e TVS/FV em 15,4%. Nenhuma variável clínica ou demográfica, discriminou o comportamento clínico ou funcional pós-implante de CDI; a recorrência de síncope pós implante de CDI, não se associou à presença de eventos arrítmicos e a hipertrofia maior que 30 mm se associou à choque precoce do CDI (p=0,003). / During 19 months of average follow-up period, we followed 26 patients with hypertrophic cardiomyopathy and high risk for sudden death, all treated by dual chamber implantable cardioverter-defibrillator. 4 patients had received appropriate ICD discharge, 4 patients with NSVT and 5 supraventricular arrhythmias. One death had occurred. Conclusions: we observed: supraventricular arrhythmias in 19,2%; NSVT in 15,4% and VT/VF in 15,4%. The clinical or demographic outcomes did not suggest any clinical or functional results after ICD implantation; syncope may occur after ICD implantation and no arrhythmias recordered by intracardiac electrograms and left-ventricular-wall thickness greater than 30 mm is associated with early ICD shocks (p=0,003).
16

Factors influencing health-related quality of life in patients with implantable cardioverter defibrillator. / CUHK electronic theses & dissertations collection

January 2013 (has links)
Wong, Mei Fung Florence. / Thesis (D.Nurs.)--Chinese University of Hong Kong, 2013. / Includes bibliographical references (leaves 178-208). / Electronic reproduction. Hong Kong : Chinese University of Hong Kong, [2012] System requirements: Adobe Acrobat Reader. Available via World Wide Web. / Abstract also in Chinese.
17

Estudo prospectivo e randomizado de profilaxia antimicrobiana para procedimentos cirúrgicos em estimulação cardíaca artificial / Prospective and randomized trial of antibiotic prophylaxis for cardiac stimulation surgical procedures

Oliveira, Júlio César de 11 September 2007 (has links)
O objetivo desse estudo foi avaliar os efeitos da administração prévia de antibiótico na incidência de complicações infecciosas em procedimentos de estimulação cardíaca artificial. Os pacientes foram selecionados em um estudo duplo-cego e randomizado (1:1). Grupo I Cefazolina (1,0g dose única) versus grupo II placebo. O comitê de segurança interrompeu o estudo após a inclusão de 649 pacientes devido à diferença entre os grupos (group I 314; grupo II 335 pacientes) em favor do uso de antibiótico: 2 infectados (0,63%) versus 11 infectados no grupo placebo (3,28%); p=0,016. Marcadores identificados por análise univariada: não uso de antibiótico; procedimentos de implantes (versus trocas); hematoma pós-operatório e duração do procedimento. O não uso de antibiótico e hematoma pós-operatório foram significantes em análise multivariada / The objective of this study was to evaluate the effects of the previous venous antibiotic administration in the incidence of infectious complications in cardiac stimulation surgical procedures. Patients were selected in a double blind, randomized (1:1) trial. Group I Cefazolin (1,0g one dose) versus group II placebo. The security committee interrupted the trial after inclusion of 649 patients due to differences between groups (group I 314; group II 335 patients) in favor of the antibiotic arm: 2 infected patients (0,63%) versus 11 infected patients in the placebo arm (3,28%); p=0,016. Markers identified by univariate analysis: non-use of preventive antibiotic; implant procedures (versus replacement); post-operative haematoma and procedure duration. The non-use of antibiotic and the post-operative haematoma were independent predictors of infection in multivariate analysis
18

Estudo prospectivo e randomizado de profilaxia antimicrobiana para procedimentos cirúrgicos em estimulação cardíaca artificial / Prospective and randomized trial of antibiotic prophylaxis for cardiac stimulation surgical procedures

Júlio César de Oliveira 11 September 2007 (has links)
O objetivo desse estudo foi avaliar os efeitos da administração prévia de antibiótico na incidência de complicações infecciosas em procedimentos de estimulação cardíaca artificial. Os pacientes foram selecionados em um estudo duplo-cego e randomizado (1:1). Grupo I Cefazolina (1,0g dose única) versus grupo II placebo. O comitê de segurança interrompeu o estudo após a inclusão de 649 pacientes devido à diferença entre os grupos (group I 314; grupo II 335 pacientes) em favor do uso de antibiótico: 2 infectados (0,63%) versus 11 infectados no grupo placebo (3,28%); p=0,016. Marcadores identificados por análise univariada: não uso de antibiótico; procedimentos de implantes (versus trocas); hematoma pós-operatório e duração do procedimento. O não uso de antibiótico e hematoma pós-operatório foram significantes em análise multivariada / The objective of this study was to evaluate the effects of the previous venous antibiotic administration in the incidence of infectious complications in cardiac stimulation surgical procedures. Patients were selected in a double blind, randomized (1:1) trial. Group I Cefazolin (1,0g one dose) versus group II placebo. The security committee interrupted the trial after inclusion of 649 patients due to differences between groups (group I 314; group II 335 patients) in favor of the antibiotic arm: 2 infected patients (0,63%) versus 11 infected patients in the placebo arm (3,28%); p=0,016. Markers identified by univariate analysis: non-use of preventive antibiotic; implant procedures (versus replacement); post-operative haematoma and procedure duration. The non-use of antibiotic and the post-operative haematoma were independent predictors of infection in multivariate analysis
19

"Cardiomiopatia hipertrófica: importância dos eventos arrítmicos em pacientes com risco de morte súbita" / Hypertrophic cardiomyopathy: sudden cardiac death in high risk patients and the role of arrhythmias

Paulo de Tarso Jorge Medeiros 10 December 2004 (has links)
Vinte e seis pacientes com cardiomiopatia hipertrófica e fatores de risco de morte súbita, foram submetidos a implante de cardioversor-desfibrilador implantável de dupla-câmara, com seguimento médio de 19 meses. Observou-se quatro choques em arritmias letais, 4 pacientes apresentaram TVNS e 5 taquiarritmias supraventriculares. Ocorreu um óbito.Conclusões: Observamos: TPSV em 19,2%; TVNS em 15,4% e TVS/FV em 15,4%. Nenhuma variável clínica ou demográfica, discriminou o comportamento clínico ou funcional pós-implante de CDI; a recorrência de síncope pós implante de CDI, não se associou à presença de eventos arrítmicos e a hipertrofia maior que 30 mm se associou à choque precoce do CDI (p=0,003). / During 19 months of average follow-up period, we followed 26 patients with hypertrophic cardiomyopathy and high risk for sudden death, all treated by dual chamber implantable cardioverter-defibrillator. 4 patients had received appropriate ICD discharge, 4 patients with NSVT and 5 supraventricular arrhythmias. One death had occurred. Conclusions: we observed: supraventricular arrhythmias in 19,2%; NSVT in 15,4% and VT/VF in 15,4%. The clinical or demographic outcomes did not suggest any clinical or functional results after ICD implantation; syncope may occur after ICD implantation and no arrhythmias recordered by intracardiac electrograms and left-ventricular-wall thickness greater than 30 mm is associated with early ICD shocks (p=0,003).

Page generated in 0.0745 seconds