• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 568
  • 164
  • 20
  • 18
  • 18
  • 17
  • 17
  • 11
  • 10
  • 9
  • 9
  • 8
  • 4
  • 4
  • 2
  • Tagged with
  • 815
  • 815
  • 518
  • 484
  • 154
  • 137
  • 127
  • 114
  • 101
  • 85
  • 80
  • 77
  • 75
  • 74
  • 60
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
531

Análise comparativa do desajuste marginal de infraestruturas de titânio sobre implantes preparadas por técnicas de fundição e CAD-CAM / Comparative analysis of misfit infraestructure of titanium implants prepared by casting technique an CAD-CAM

Montagner, Antonio Marcos, 1971- 23 August 2018 (has links)
Orientador: Rafael Leonardo Xediek Consani / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-23T22:33:52Z (GMT). No. of bitstreams: 1 Montagner_AntonioMarcos_D.pdf: 6435391 bytes, checksum: 672d4a9fae3c6efb41c8c35054b62598 (MD5) Previous issue date: 2013 / Resumo: O objetivo do presente trabalho foi determinar e comparar o desajuste entre infraestruturas protéticas e cilindros protéticos do tipo mini pilar cônico e análogo produzidos por fundição e usinagem por CAD-CAM. Foram selecionados dois grupos de próteses preparadas com duas técnicas de confecção laboratorial, uma convencional com fundição de titânio por cera perdida e outra baseada na fresagem de peças pré-fabricadas por sistema de CAD-CAM e unidas por soldagem a laser. As infraestruturas de titânio foram elaboradas sobre uma matriz metálica de aço inox onde foram adaptados de forma alinhada quatro análogos de Micro-Unit (Conexão® Sistemas de Prótese) para simular uma prótese fixa sobre implantes com dois pré-molares e dois molares. As peças fresadas foram usinadas individualmente e depois soldadas a laser. As fundições foram sobre cilindros calcináveis encerados e fundidos em monobloco. Os dois grupos denominados grupo controle para o das infraestruturas fundidas e grupo teste para o das infraestruturas fresadas tiveram seu desajuste marginal mensurado por meio de microscopia eletrônica de varredura. Determinou-se o desajuste vertical e horizontal das partes. Os desajustes foram medidos em quatro tempos para cada grupo. No grupo controle as medidas foram a inicial, após enceramento, após fundição e após ciclagem. No grupo teste as medidas foram a inicial, após fresagem, após soldagem e após ciclagem. Os valores foram medidos em micrometros e para desajuste horizontal, valores positivos foram descritos quando os cilindros possuíam dimensão maior que a do análogo, enquanto que negativo foi para os casos de cilindro protético menor que a base do análogo, sugerindo plataforma "switching". Todas as leituras e medidas foram realizadas por um único operador. Os resultados mostraram uma diferença estatística significativa tanto no desajuste horizontal como no vertical, com os menores valores médios para o grupo teste (CAD-CAM) no desajuste vertical e para o controle (fundição) no desajuste horizontal. A média de desajuste vertical ao final das peças elaboradas foi de 10,16 ± 6,55 ?m para grupo teste e 251,49 ± 72,3 ?m para grupo controle, enquanto no sentido horizontal foi de 143,37 ± 159,77 ?m para grupo teste e - 11,47 ± 50,29 ?m para grupo controle. A maior ocorrência de valores negativos no sentido horizontal se deu para o grupo controle, sugerindo a existência de cilindros com plataforma "switching". Este resultado pode ser justificado devido a falta de curva de aprendizado e falha na estipulação de parâmetros do sistema CAD/CAM utilizado no experimento para o grupo teste (Biogenie® Rio de Janeiro, Brasil). Concluiu-se que as infraestruturas metálicas em titânio preparadas pela metodologia CAD/CAM, é uma alternativa viável e que é possível produzir infraestruturas para próteses com desajuste vertical menor que o obtido pela técnica de fundição por cera perdida. / Abstract: The objective of this study was to determine and compare the mismatch between prosthetic frameworks and prosthetic cylinders type mini tapered pillar and analogue produced by casting and machining for CAD-CAM. We selected two groups of prostheses prepared with two laboratory techniques to manufacture a conventional titanium castings lost wax and another based on milling prefabricated parts for CAD-CAM system and joined by laser welding. Titanium framawork have been prepared on a metallic stainless steel which have been adapted so aligned four analogues Micro-Unit (Conexão Sistemas de Prótese) to simulate a fixed prosthesis on implants with two premolars and two molars. The milled parts were machined individually and then laser welded. The castings were on cylinders calcinable waxed and cast monoblock. Both groups called for the control group and the test group merged infrastructure for infrastructure milled had their misfit measured by scanning electron microscopy. We determined the horizontal and vertical misalignment of the parts. Misfits were measured at four time points for each group. In the control group the measurements were the initial, after waxing, after casting and after cycling. In the test group the measures were the start, after milling, after welding and after cycling. The values were measured in micrometers and horizontal misalignment positive values when the cylinders have been described possess the largest dimension of the analogue, while it was negative for the cases of less than prosthetic cylinder base analogue, suggesting "switching" platform. All readings and measurements were performed by a single operator. The results showed a statistically significant difference in both the horizontal and the vertical misfit, with the lowest values for the test group (CAD-CAM) in the vertical misfit and control (casting) in horizontal misfit. The average vertical misfit at the end of the elaborate pieces was 10.16 ± 6.55 ?m for the test group and 251.49 ± 72.3 ?m for the control group, while in the horizontal direction was 143.37 ± 159.77 ?m for the test group and -11.47 ± 50.29 ?m for the control group. The greater occurrence of negative values in the horizontal direction is given to the control group, suggesting the existence of cylinder "switching" platform. This result can be justified due to lack of learning curve and failure stipulation parameters of CAD/CAM system used in the experiment for the test group (BIOGENIE® Rio de Janeiro, Brazil). Concluded that the titanium metal frameworks prepared methodology for CAD/CAM, is a viable alternative and that it is possible to produce frameworks prostheses with vertical misfit lower than that obtained by the technique of lost wax casting. / Doutorado / Protese Dental / Doutor em Clínica Odontológica
532

Influência do material de infraestrutura e do desajuste vertical de próteses parciais fixas implantossuportadas nas tensões transmitidas às estruturas protéticas e ao tecido ósseo peri-implantar / Influence of framework material and vertical misfit of implant-suported partial prostheses on the stresses in prosthetic structures and peri-implant bone tissue

Bacchi, Ataís, 1986- 19 August 2018 (has links)
Orientador: Rafael Leonardo Xediek Consani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-19T19:18:16Z (GMT). No. of bitstreams: 1 Bacchi_Atais_M.pdf: 865962 bytes, checksum: 55e25bc8a48c9b1870a41c704082365a (MD5) Previous issue date: 2012 / Resumo: O objetivo neste estudo foi avaliar a influência do material de infraestrutura e diferentes níves de desajuste vertical na concentração de tensões em prótese parcial fixa implantossuportada (infraestrutura e porcelana de cobertura), parafuso de retenção e tecido ósseo peri-implantar durante o assentamento protético e frente à aplicação de carga oclusal. Um modelo tridimensional de elementos finitos de uma porção posterior de mandíbula contendo dois implantes osseointegrados nas posições de segundo pré-molar e segundo molar, suportando uma prótese parcial fixa foi construído utilizando software específico de modelagem (SolidWorks 2010). Modelos de elementos finitos foram obtidos pela importação do modelo sólido ao software de simulação mecânica (ANSYS Workbench 11). Os modelos foram separados em grupos de acordo com o material de infraestrutura (liga de ouro tipo IV, liga de prata-paládio, titânio comercialmente puro, liga de cobalto-cromo ou zircônia) e o nível de desajuste vertical (10 ?m, 50 ?m e 100 ?m) criado na interface prótese-implante do segundo pré-molar. A concentração de tensões foi avaliada nas seguintes condições: (1) assentamento protético; e (2) cargas oclusais simultâneas de 110 N vertical e 15 N horizontal em cada dente. Os resultados obtidos mostraram que as infraestruturas mais rígidas apresentam maior concentração de tensões internas; entretanto, promoveram menores concentrações de tensão sobre a porcelana de recobrimento, em ambas condições avaliadas. Na análise do assentamento protético, materiais mais rígidos para infraestruturas aumentaram os valores de tensão no parafuso de retenção e não causaram diferença relevante nas tensões no tecido ósseo peri-implantar. Quando a carga foi aplicada, o uso de infraestruturas mais rígidas promoveu redução de tensões no parafuso de retenção e no tecido ósseo peri-implantar. Em ambas condições avaliadas um considerável aumento na concentração de tensões foi obsevado em todas as estruturas com a amplificação do desajuste. Nas diferentes simulações, o material de infraestrutura exerceu considerável influência nas tensões transmitidas às estruturas avaliadas, exceto ao tecido ósseo peri-implantar em condições de assentamento. Aumento de tensões em todas as estruturas pode ser observado com o aumento do desajuste / Abstract: The aim in this study was to evaluate the influence of the framework material and vertical misfit on the stresses created in an implant-supported partial prosthesis (framework and porcelain veneer), retention screw and peri-implant bone tissue during the settlement of the prosthesis and under load conditions. A 3-D Finite Element model of a posterior part of a jaw with two osseointegrated implants at the place of the right second pre-molar and second molar supporting an implant-supported fixed partial prosthesis was constructed using specific modeling software (SolidWorks 2010). Finite element models were obtained by importing the solid model into mechanical simulation software (ANSYS Workbench 11). The models were divided into groups according to the framework material (type IV gold alloy, silver-palladium alloy, commercially pure titanium, cobalt-chromium alloy or zirconia) and vertical misfit level (10 ?m, 50 ?m and 100 ?m) created at the second pre-molar implant-prosthesis interface. The stress concentration was evaluated in the following conditions: (1) settlement of the prosthesis; and (2) simultaneous loads of 110 N vertical and 15 N horizontal in each tooth. The obtained results showed that stiffer frameworks presented higher stress concentrations in it and led to lower stresses in the porcelain veneer, in both conditions. In the analysis of settlement of the prosthesis, stiffer framework materials increased the stress values in the retention screw and did not cause a relevant difference in the stresses values in peri-implant bone tissue. When the load was applied, the use of more stiffness frameworks led to lower stresses in the retention screw, and peri-implant bone tissue. In both conditions evaluated, considerable raise of stress concentration was observed in all the structures within misfit amplification. Comparing the results of the different simulations, the framework materials presented a considerable influence on the stress concentration in the structures evaluated, except on the peri-implant bone tissue during the settlement of the prosthesis, while a considerable increase of the stress in all the structures was observed with the increase of the misfit / Mestrado / Protese Dental / Mestre em Clínica Odontológica
533

Influência da ancoragem apical na estabilidade primária e comportamento biomecânico de implantes sub-cristais / Influence of the apical anchorage on primary stability and biomechanical behavior of subcrestal implants

Andrade, Camila Lima de, 1984- 21 August 2018 (has links)
Orientador: Altair Antoninha Del Bel Cury / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-21T17:30:39Z (GMT). No. of bitstreams: 1 Andrade_CamilaLimade_M.pdf: 1540257 bytes, checksum: bda7c72558234d710525932300d299a1 (MD5) Previous issue date: 2012 / Resumo: Este estudo avaliou a influência da ancoragem apical de implantes sub-cristais com plataforma switching em região posterior de maxila quanto a estabilidade primária e comportamento biomecânico. Quatro modelos de ancoragem óssea foram utilizados nas avaliações: implante de 4,0 x 13 mm de comprimento fixado bicorticalmente (A), implante de 4,0 × 11 mm de comprimento ancorado apenas na cortical da crista (B) ou 2 milímetros posicionados sub-cristal com (C) ou sem (D) o ápice ancorado no osso cortical do assoalho do seio maxilar. A estabilidade primária foi verificada pelo torque de inserção e medida de frequência de ressonância (ISQ) de implantes inseridos em blocos de poliuretano (n=5). O comportamento biomecânico foi obtido através de análise por elementos finitos (AEF), em que os modelos virtuais foram construídos para representar as diferentes ancoragens ósseas. O tecido ósseo foi considerado anisotrópico e um coeficiente de fricção de 0,3 foi utilizado na interface osso-implante para simular carregamento imediato. Todos os modelos foram carregados com 200 N de força distribuída em três pontos oclusais na coroa cerâmica do pré-molar para simular contato cêntrico ou um contato na cúspide vestibular para simular contato excêntrico. A ancoragem do ápice na cortical óssea aumentou a estabilidade primária dos implantes sub-cristais (torque de inserção 43.2±4.1; ISQ 77.2±2.4), entretanto, também aumentou os valores de tensão / deformação quando comparado com o implante sub-cristal ancorado apenas em osso trabecular. O osso trabecular é capaz de dissipar as tensões pelo aumento da micromovimentação, especialmente sob carga excêntrica. A ancoragem do ápice dos implantes sub-cristais na cortical do seio maxilar é benéfica do ponto de vista biomecânico, por direcionar as forças tanto cêntricas quanto excêntricas para a região cortical e contribuir para diminuir a micromovimentação do implante / Abstract: This study evaluated the influence of apical anchorage of implants with platform switching at posterior maxilla on primary stability and biomechanical behavior of subcristal implants. Four anchorage designs were used in evaluations: one 4.0×13 mm length implant was fixed bicortically (A), and one 4.0×11 mm length implant was anchored only in crystal cortical (B) or positioned 2 mm subcrestally with (C) or without (D) its apex anchored in cortical bone. Primary stability was accessed by insertion torque and resonance frequency measurements (ISQ) of implants inserted in polyurethane blocks (n=5). The biomechanical behavior was accessed by finite element analysis (FEA), in which virtual models were constructed to representing one of the anchorage designs. The bone tissue was considered anisotropic and a 0.3 frictional coefficient was used at the implant-bone interface to simulate immediate placement. All models were loaded with 200 N force distributed over three occlusal points on the premolar ceramic crown to simulate centric contacting or over one contact at buccal cusp to simulate eccentric contacting. The anchorage of apex into cortical bone testing material improved the primary stability of subcrestal implants (insertion torque 43.2 ± 4.1; ISQ 77.2 ± 2.4); however, the stress/strain values also increased when compared to the subcristal implant anchored only into trabecular bone. The trabecular bone is able to dissipate the stresses by increasing micromotion, especially at eccentric loading. The anchorage of subcristal implant apex into sinus floor cortical bone is biomechanically beneficial, for directing the centric and eccentric forces to cortical region and reduces the micromotion implant / Mestrado / Protese Dental / Mestra em Clínica Odontológica
534

Detection of periimplant fenestration and dehiscence using CBCT - an in vitro study = Diagnóstico tomográfico de fenestração e deiscência peri-implantar - estudo in vitro / Diagnóstico tomográfico de fenestração e deiscência peri-implantar - estudo in vitro

Vaz, Sergio Lins de Azevedo, 1984- 22 August 2018 (has links)
Orientador: Francisco Haiter Neto / Tese (Doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-22T00:06:43Z (GMT). No. of bitstreams: 1 Vaz_SergioLinsdeAzevedo_D.pdf: 2097588 bytes, checksum: 48e378674d749eb9b8ea2a05042e21a4 (MD5) Previous issue date: 2013 / Resumo: O presente estudo se propôs a avaliar a influência do tamanho de voxel e giro de escaneamento na detecção tomográfica de fenestração e deiscência peri-implantar, além do uso de filtros de imagem na detecção da deiscência peri-implantar. Em fragmentos de costelas bovinas, foi criado defeitos que simulariam fenestração e deiscência peri-implantar após a instalação de 100 implantes de titânio. As imagens foram adquiridas no tomógrafo computadorizado de feixe cônico i-CAT Next Generation, empregando FOV de 8 x 8 cm e três protocolos: A- voxel de 0,2 mm, giro de escaneamento de 180°; B- voxel de 0,2 mm, giro de 360°; C- voxel de 0,12 mm, giro de 360°. Cinco filtros do programa XoranCat foram testados: Angio Sharpen High 5x5, Shadow, Sharpen 3×3, Sharpen Mild e Smooth. Três cirurgiões-dentistas radiologistas identificaram a presença ou ausência dos defeitos. Curvas ROC foram criadas e os valores de área sob a curva (Az) comparados utilizando a Análise de Variância (ANOVA), com teste post hoc de Bonferroni (alfa de 5%). O teste de McNemar foi utilizado para comparar imagens (originais e com filtros) versus padrão ouro, bem como imagens originais versus imagens com filtros. Os resultados mostraram diferenças estatisticamente significantes entre os valores de Az dos protocolos B e C em relação ao protocolo A (p < 0,01) para deiscência. Houve diferenças estatisticamente significantes (p < 0,01) entre as imagens originais e o filtro Shadow em relação ao padrão ouro, bem como entre todos os filtros testados em relação às imagens originais. Concluiu-se que os tamanhos de voxel testados não influenciaram no diagnóstico de ambos os defeitos, enquanto que o giro de escaneamento completo (360°) foi melhor para deiscência. Diante da maior dificuldade no diagnóstico tomográfico de deiscência peri-implantar, o uso dos filtros de imagem testados é aconselhado, com exceção do filtro Shadow / Abstract: This study set out an assessment of the effects of two voxel sizes and scan modes of cone-beam computed tomography (CBCT) in periimplant fenestration and dehiscence detection. It also aimed to investigate whether CBCT filters would enhance the diagnosis of periimplant dehiscence. One hundred titanium implants were placed in bovine ribs in which periimplant fenestration and dehiscence were simulated. The images were acquired using the i-CAT Next Generation CBCT unit, with a FOV of 8 x 8 cm and the following protocols: A- 0.2 mm voxel size half-scan (180°); B- 0.2 mm voxel size full-scan (360°); and C- 0.12 mm voxel size full-scan (360°). Five filters of the XoranCat software were tested: Angio Sharpen High 5x5, Shadow, Sharpen 3×3, Sharpen Mild and Smooth. Three oral radiologists performed a dynamic evaluation of the presence/absence of the defects and ROC curves were created. The values of the area under the curve (Az) were compared with ANOVA and Bonferroni post-hoc test. The significance level was adopted at 5%. The McNemar test was applied to perform two comparisons in order to identify disagreements. All the enhanced and the original images were compared with the gold-standard and the original images were compared to the enhanced ones. The protocol A had significantly lower Az values than those obtained with the protocols B and C (p < 0.01) for dehiscence. The original images and the Shadow filter were statistically different from the gold-standard (p < 0.01). All the enhanced images also had statistically significant differences from the original images (p < 0.01). In conclusion, the voxel sizes did not influence in periimplant fenestration and dehiscence detection but the full-scan (360°) performed better than the half-scan for dehiscence. The use of enhancement CBCT filters for dehiscence detection is advised, with the exception of the Shadow filter / Doutorado / Radiologia Odontologica / Doutor em Radiologia Odontológica
535

Analise das cirurgias de elevação de seio maxilar para instalação de implantes osseointegraveis na Faculdade de Odontologia de Piracicaba Unicamp: estudo retrospectivo de seis anos

Luna, Anibal Henrique Barbosa 02 November 2005 (has links)
Orientador: Jose Ricardo Albergaria Barbosa / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-04T03:21:31Z (GMT). No. of bitstreams: 1 Luna_AnibalHenriqueBarbosa_M.pdf: 8812225 bytes, checksum: 08ad7a117ec4977c4d2b22e6093a6a82 (MD5) Previous issue date: 2005 / Resumo: Reabilitações na região posterior da maxila são geralmente confrontadas com atrofia óssea, associada à pneumatização do seio maxilar, impedindo a instalação de implantes de comprimento adequado. A cirurgia de elevação do seio maxilar foi introduzida na literatura em 1980, por Boyne & James, para permitir a instalação de implantes osseointegráveis nesta região, apresentando desde então algumas modificações que resultam em diferentes índices de sucesso e de complicações. Este estudo retrospectivo envolveu uma análise de 72 pacientes tratados em um período de 06 anos pela Área de Cirurgia Buco-Maxilo-Facial da Faculdade de Odontologia de Piracicaba - Unicamp. A amostra foi representada por um total de 91 seios maxilares, que receberam elevação associada a diferentes materiais de preenchimento para instalação de 101 implantes. Um total de 70 implantes (69,3%) foi instalado em um segundo procedimento cirúrgico, com um tempo médio decorrido desde a elevação de 9,88± 4,27 meses. Em 13 pacientes (18,5%) a reabilitação implanto-suportada foi abortada. Um total de 35 pacientes (48,61%) encontra-se em fase de reabilitação; 24 pacientes (33,33%) encontram-se reabilitados com próteses implanto-suportadas coroas unitárias, próteses fixas ou overdentures - com um tempo médio de acompanhamento de 25,54 ± 23,75 meses. O índice de sucesso neste período foi de 88,24% / Abstract: Rehabilitation of the posterior maxilla is often impaired by bone atrophy, associated with maxillary sinus pneumatization, preventing the installation of implants of ideal length. Maxillary sinus elevation was first introduced in the literature in 1980, by Boyne & James, as an attempt to allow the placement of osseointegrated implants in this region, and several modifications have been presented resulting in different success and complication rates. This retrospective study involved an analysis of 72 patients treated during a period of 6 years in the Oral and Maxillofacial Surgery Area, Piracicaba Dental School - Unicamp. The sample was represented by 91 maxillary sinuses that had been subjected to elevation associated with different grafting materiais, for the installation of 101 implants. In 13 patients (18.50%), implantsupported rehabilitation had been aborted; in 35 patients (48.61%), it had not been finished; 24 patients (33.33%) had already received rehabilitation with implant-supported prostheses unitary crowns, fixed prostheses or overdentures - with a mean follow-up period of 25.54 ± 23.75% months. The success rate in this period was 88.24% / Mestrado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Mestre em Clínica Odontológica
536

Adaptação marginal de infra-estruturas implanto-retidas obtidas por tecnica de fundição-sobre-analogos

Fragoso, Wagner Sotero 23 February 2005 (has links)
Orientador: Guilherme Elias Pessanha Henriques / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-04T03:50:42Z (GMT). No. of bitstreams: 1 Fragoso_WagnerSotero_M.pdf: 846623 bytes, checksum: 8a6eb47d9e498f7baef57b0a8a9006b6 (MD5) Previous issue date: 2005 / Resumo: A redução de desajustes marginais em estruturas suportadas por implantes osseointegrados é requerida para maior longevidade das fixações. Este trabalho teve o propósito de avaliar o desajuste marginal de infra-estruturas metálicas implanto-retidas fundidas em titânio comercialmente puro (Ti c.p.) pela técnica de fundição-sobre-análogos, comparando os resultados com estruturas obtidas pela incorporação de cilindros cimentados e pela técnica convencional de fundição tipo monobloco. A partir de uma matriz metálica mandibular contendo 05 análogos de abutments tipo Micro Unit, 10 estruturas foram obtidas de modelos elaborados em revestimento pela fundição-sobre-análogos. Estruturas com cilindros incorporados mediante cimentação por agente resinoso e pela técnica convencional em monobloco, foram manufaturadas de outros 20 modelos elaborados em gesso. As leituras de desajuste foram conduzidas num microscópio mensurador com aumento de 120X, tendo sido baseadas no protocolo do aperto de 10 Ncm em um único parafuso distalmente posicionado e avaliação de desajuste no segmento em alça. Pelo Análise de Variância e teste de Tukey foram constatadas diferenças estatísticas significativas (P=0,01) entre os valores médios do grupo cilindro cimentado (27,90±6,61µm), monobloco (332,87±63,91µm) e fundição-sobre-análogos (97,70±40,53µm). As estruturas metálicas implanto-retidas obtidas pela técnica de fundição-sobre-análogos apresentaram melhor adaptação marginal que as fundidas em monobloco, mas com maior desajuste que as estruturas com cilindros cimentados / Abstract: The reduction of marginal gap in osseointegrated implant-supported frameworks is required for longevity of the settings. The purpose of this study was to evaluate the marginal misfit of cast implant-retained frameworks made from commercially pure titanium (CP Ti) comparing: the over-analog casting technique, cemented cylinders technique, and the conventional one-piece casting technique. From a mandibular master cast containing 05 Micro Unit abutment analogs, 10 frameworks were made from investment material for over-analog casting technique. Twenty dental stone casts were used for both cemented cylinder and one-piece casting techniques. A resinous agent was used for the cemented cylinders technique. The marginal gaps were measured using a traveling microscope (×120) by means of single-screw test protocol: tightness of 10 Ncm of distal screw and evaluation of marginal gap in the opposed extension. Mean marginal misfit data were calculated for each framework. Analysis of Variance and Tukey test exhibited statistical significant differences (P=0.01) among the misfit mean values of the cemented cylinders group (27.90±6.61µm), one-piece casting group (332.87±63.91µm) and over-analog casting group (97.70±40.53µm). The over-analog casting technique provided a smaller marginal misfit than one-piece casting technique, however the over-analog casting technique resulted in a higher marginal gap than cemented cylinders technique / Mestrado / Protese Dental / Mestre em Clínica Odontológica
537

Surface characteristics and in vitro bio-acceptability of machined and cast pure titanium and titanium alloy

Carneiro, Lorna Celia 30 September 2005 (has links)
Please read the abstract in the section 00front of this document / Thesis (PhD (Dentistry))--University of Pretoria, 2005. / Community Dentistry / unrestricted
538

Avaliação da manutenção da pre-carga de parafusos de ouro e titanio em proteses implanto-suportadas / Pre-load maintenance in abutment and prosthetic screws implant restoration after simulated load cycling: an in vitro study

Panza, Leonardo Henrique Vadenal, 1982- 12 January 2006 (has links)
Orientador: Altair Antoninha Del Bel Cury / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-07T21:11:17Z (GMT). No. of bitstreams: 1 Panza_LeonardoHenriqueVadenal_M.pdf: 663328 bytes, checksum: 9c68a1e736e333278ff91bfba5ca2da4 (MD5) Previous issue date: 2006 / Resumo: O sucesso da terapia reabilitadora com implantes requer um equilíbrio entre fatores biológicos e mecânicos. Os fatores biológicos são multifatoriais, já os mecânicos associam-se à instabilidade da conexão implante-parafuso-intermediário. Entre os fatores responsáveis pela manutenção da estabilidade desta conexão, a manutenção da pré-carga do parafuso é o mais importante. Com base nestas informações, este estudo buscou avaliar a manutenção da pré-carga de parafusos de ouro, após a aplicação de carga simulada, por meio da realização de ciclagem mecânica do conjunto protético, e também observar a ocorrência de rotação da coroa ou do intermediário protético em relação aos implantes. Para tanto, foram utilizados 40 implantes, 20 com hexágono interno e 20 externo, conectados a intermediários protéticos do tipo Esteticone com angulação de 17° e sem angulação, todos retidos por parafusos de titânio rosqueados a 20N/cm, sobre os quais foram parafusadas coroas confeccionadas em resina acrílica simulando pré-molares superiores humanos com parafusos de ouro apertados a 10N/cm. Cada conjunto foi então submetido ao ensaio de fadiga com aplicação de forças médias de 115 N no sentido do longo eixo do implante por 0.2 s, com uma freqüência de 1 Hz, totalizando um total de 250.000 de ciclos (correspondendo aproximadamente a 3 meses de uso). A manutenção da pré-carga dos parafusos, foi avaliada pelo destorque dos parafusos, após a realização do ensaio de fadiga, com a utilização de um torquímetro digital. Os resultados foram então submetidos à análise de variância a 2 critérios e ao teste de Tuckey, através dos quais foi possível observar que, para o parafuso protético, ocorreu diferença estatisticamente significante entre os tipos de implante, mas sem interação com o tipo de intermediário. No entanto para o parafuso do intermediário ocorreu diferença significativa tanto para o tipo de implante como entre os intermediários, com interação entre os fatores. A análise estatística apontou um desempenho melhor para a manutenção da pré-carga inicial dos parafusos, nos intermediários angulados tanto nos implantes de hexágono interno, quanto nos de hexágono externo. Nenhum dos corpos de prova apresentou rotação de coroa ou intermediário protético quando analisados ao microscópio / Abstract: After osseointegration failures, screw loosening is the most common problem in implant dentistry. However, controversies still exist regarding to the influence of type connection implant to abutment in screw loosing or fracture. This study evaluated pre-tightening maintenance in abutment and prosthetic screws of external and internal implant hexagon with standard and 17° angulated abutments after fatigue testing. Also, the rotational dislodgement was checked using digital measurement microscope. Four subsets (n=10) of implants and abutments were assessed: (G1) internally hexed implant and standard abutment (G2) internally hexed implant and 17° angulated abutment (G3) externally hexed implant and standard abutments (G4) externally hexed implant and 17° angulated abutment. Abutments were retained by titanium screws tightened to 20 N/cm. Acrylic resin crowns were manufactured and were retained over the abutments with gold screws tightened at 10 N/cm, using an electronic torque controller. A vertical line was ascribed across the implant-abutment and crown-abutment interface to identify any rotational displacement. The fatigue tests were performed in a servo-hydraulic machine which delivered forces between 100 and 120 N for 250,000 cycles, through a piston to the crown. The implant-abutment interface were evaluated using a light microscope. Then, screw was removed and detorque value was recorded. Data were statistically analyzed using ANOVA and Tukey test (a=.05) No horizontal displacement of acrylic resin crown and abutments were observed. ANOVA showed significant difference for prosthetic screw between implant types, but without interaction with abutment. However, for abutment screw, there was a significant difference between implant type and abutment. Also, it was observed interaction between implant and abutments types. Internally hexed implants (G1 and G2) and externally hexed implants (G3 and G4) showed significant difference with a better performance for angulated abutment in comparison to standard abutment. Within the limitations of this study it was concluded that pre-tightening maintenance of screw was affected by the type of abutment and the type connection implant used. There was no dislodgement for crown or abutment when standard or pre-angulated abutments were used after 250.000 cycles of simulated loading. Indeed, internal and external hexed connections were effective to avoid rotation of crowns / Mestrado / Protese Dental / Mestre em Clínica Odontológica
539

Análise tridimensional por elementos finitos do comportamento biomecânico de overdenture com sistema barra-clipe reembasada com material permanente macio ou rígido / A three-dimensional Finite Element Analysis of the biomechanical behavior of overdenture bar-clip system relined with soft or hard permanent material

Silva, Tales Candido Garcia da, 1987- 22 August 2018 (has links)
Orientador: Rafael Leonardo Xediek Consani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-22T06:41:00Z (GMT). No. of bitstreams: 1 Silva_TalesCandidoGarciada_M.pdf: 2333954 bytes, checksum: ce4e52cbe9b7265639ebc9bf9cbdb40b (MD5) Previous issue date: 2013 / Resumo: O processo de reabsorção do osso mandibular e do peri-implantar promove desadaptação das bases protéticas, causando aumento das tensões geradas pelas próteses e componentes, exacerbando a reabsorção óssea. Com o intuito de readaptar bases protéticas ao rebordo subjacente, o uso de reembasadores tem sido indicado. O objetivo neste trabalho foi analisar pelo método de Elementos Finitos as tensões no osso peri-implantar, rebordo posterior e componente protéticos em overdenture com reabsorção óssea simulada (na instalação da prótese, 3, 5 e 10 anos de uso) e reembasamento com materiais permanentes macio ou rígido. Foi utilizado software específico para modelagem (SolidWorks 2010) para a geração tridimensional dos componentes protéticos e base da mandíbula. Foram gerados quatro modelos mandibulares, que simulavam as perdas ósseas do rebordo posterior e peri-implantar, de acordo com os tempos avaliados neste estudo e com ou sem o uso de reembasadores macios ou rígidos. Os modelos por Elementos Finitos foram obtidos com a exportação dos modelos sólidos para software específico de simulação mecânica (ANSYS Workbench 11), com carga de 100 N na região do primeiro molar direito. O modelo que simula o momento da instalação da prótese gerou os menores resultados de tensão para todos os componentes e situações analisadas. A distribuição de tensões nos modelos com 3, 5 e 10 anos de reabsorção foi semelhante quando se avaliou a localização das tensões; entretanto, maior acúmulo foi verificado nos componentes protéticos e tecido ósseo, sempre ao lado de aplicação da carga. Quanto mais tempo de reabsorção, maiores eram os valores de tensão gerados, com influência dos materiais reembasadores que diminuíram os valores tensionais. Materiais reembasadores rígidos promoveram melhor distribuição e menores valores de tensão que reembasadores macios, sendo mais eficientes que os modelos sem material reembasador. Conclui-se que: a) o aumento da reabsorção dos rebordos posterior ou peri-implantar promoveu aumento de tensões tanto nos componentes protéticos como no tecido ósseo; b) o uso de reembasadores macio ou rígido atenuou as tensões geradas, qualquer que fosse à resiliência do material; c) o reembasador rígido foi mais eficiente na diminuição das tensões quando comparado ao reembasador macio / Abstract: The process of ridge posterior and peri-implant bone resorption promotes misfit between overdenture base and mandibular ridge, which culminates in increased stresses generated by prostheses and their components, exacerbating bone resorption. Relines have being used in order to readapt the prosthetic bases. This three-dimensional finite elements method study aimed to evaluate the effect stress of a overdenture in models that simulated bone resorption (in installing prosthesis, 3, 5 and 10 years of use) and reline materials (soft or hard) on stress distribution in posterior ridge, surrounding bone and implant prosthetic components. Through the computer aided design software (SolidWorks 2010), three-dimensional prosthetic components were built and jaw models from images of the mandible computerized tomography. Four models were generated simulating mandibular bone loss according to times and use of hard or soft relines. These geometric models were obtained through export to the specific mechanical simulation software (ANSYS Workbench 11), and subjected to a load of 100 N in the first right molar region. The lowest observed values were in the period of installation prosthesis for all components and situations. The stress distributions in models with 3, 5 and 10 years of resorption were similar considering the location of tensions; however, the stress concentration increased values in the prosthetic components and bone, always on the side of load application. The longer resorption, the higher stress values were generated, with the Influence of reline materials. Hard reline materials promoted better distribution and lower stress values than soft reline, demonstrating models with more effectiveness than in with no reline. It can be concluded that: a) the power increase of posterior ridge or peri-implant bone resorption promotes increased tensions in the prosthetic components in the bone tissue, b) the use of soft or hard relines, minimized the generated tensions, regardless the stuff resilience, c) the hard reline was more efficient in reducing tensions when compared to soft reline / Mestrado / Materiais Dentarios / Mestre em Materiais Dentários
540

Influência dos fatores protéticos em implantes curtos e análise da distribuição de tensão proveniente dos torques de inserção / Influence of the short implant prosthetic factors implants and the stress distribution from the insertion torques

Sotto-Maior, Bruno Salles, 1981- 18 August 2018 (has links)
Orientador: Altair Antoninha Del Bel Cury / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-18T14:29:43Z (GMT). No. of bitstreams: 1 Sotto-Maior_BrunoSalles_D.pdf: 741251 bytes, checksum: 2ebe371e794a4ee4163f50485af657a2 (MD5) Previous issue date: 2011 / Resumo: Os implantes curtos são uma alternativa terapêutica para rebordos reabsorvidos. Entretanto, em regiões posteriores atróficas apresentam maior risco biomecânico, devido às coroas protéticas mais longas decorrente do aumento do espaço inter-maxilar. Com objetivo de compensar a biomecânica desfavorável é aconselhável utilizar materiais restauradores menos rígidos, sistemas de retenção da prótese que facilitem a dissipação de tensões e uso de implantes com diâmetros maiores. Contudo, a influência desses fatores protéticos e o torque de inserção na concentração de tensões não está claramente esclarecida. Assim, os objetivos deste trabalho foram avaliar por meio do método dos elementos finitos tridimensional: I) A influência dos fatores protéticos (proporção coroa-implante (C/I), sistema de retenção da prótese, material restaurador e tipo de carregamento oclusal) na concentração de tensões nas regiões do osso cortical, medular, parafuso protético e no implante de prótese unitária suportada por implante curto; II) Avaliar a influência de diferentes torques de inserção na distribuição de tensão e deformação do osso cortical e medular. Para o primeiro objetivo foram criados 32 modelos da parte posterior de uma mandíbula atrófica. Cada modelo recebeu uma coroa metalocerâmica ou cerâmica pura, cimentada ou parafusada, sobre um implante de 7 mm de comprimento e 5 mm de diâmetro na região de primeiro molar. A proporção coroa-implante variou 1:1, 1.5:1, 2:1 ou 2.5:1. Os modelos foram carregados simulando uma oclusão normal ou traumática. Após o teste de convergência a 5% para determinar o refinamento da malha à análise numérica foi realizada com o programa Ansys Workbench 10.0®. A tensão máxima principal (?max) para o osso cortical e osso medular e a tensão de von Mises (?vM) para o implante e parafuso protético foram obtidos e submetidos à análise da variância. Para o segundo objetivo, seis modelos da pré-maxila foram construídos com um implante e carregados com 30, 40, 50, 60, 70 ou 80 Ncm de toque de inserção. A ?max e a deformação máxima principal (?max) foram obtidos para o osso cortical e medular. O teste de correlação de Pearson foi utilizado para determinar a correlação entre torque de inserção e a concentração de tensões e deformações no tecido ósseo periimplantar. Como resultados, observou-se que a oclusão traumática e o aumento da proporção C/I aumentaram significativamente a concentração de tensão no osso cortical, osso medular, parafuso protético e no implante. O sistema de retenção apresentou influência significativa (p<0.02) na concentração de tensão, porém menor do que a oclusão e a proporção C/I. As próteses parafusadas apresentaram maiores tensões quando comparadas as próteses cimentadas em todas as regiões avaliadas. A concentração de tensão não foi afetada pelo material restaurador. Para o segundo objetivo observou-se que o aumento do torque de inserção aumenta a ?max e ?max para o osso cortical e medular. Conclui-se que o tipo de carregamento oclusal foi o fator avaliado que mais influenciou na concentração de tensão em prótese unitária suportada por implante curto e que torques de inserção de maior magnitude aumentam as concentrações de tensão e deformação no tecido ósseo periimplantar / Abstract: The short implants are an alternative treatment for edges reabsorbed. However, using short implant at the posterior atrophic mandibular has showed higher biomechanical risk due to higher crown following to the increase of inter-maxillary space. Aiming to offset the unfavorable biomechanics is advisable to use less rigid restorative materials, retention system for the prosthesis to facilitate the stress distribution and use of implants with larger diameters. However, the influences of these prosthetic factors and insertion torque on stress concentration are not clearly understood. Thus, the objectives were to evaluate by tridimensional finite element method the influence of: I) crown-to-implant (C/I) ratio, retention system, restorative material and occlusal loading on stress concentrations within a single posterior crown supported by a short implant; II) different insertion torques on the stress and strain distribution in cortical and cancellous bones. For the first objective, thirty-two finite element models of an atrophic posterior edentulous mandible were created. Each model received a metal-ceramic crown, cemented or screwed, over a single external hexagon implant with 7 mm length and 5 mm diameter at the first molar region. The C/I ratio ranged from 1:1, 1.5:1, 2:1 to 2.5:1. The models were loaded by simulating a normal and traumatic occlusion. After the convergence analysis of 5% to mesh refinement, the numerical analysis was performed on Ansys Workbench 10.0® software. The maximum principal stress for cortical and cancellous bone and von Mises stress (?vM) for the implant and abutment screw were computed and analyzed using analysis of variance. For the second objective, six models were built and each of them received an implant with one of the following insertion torques: 30, 40, 50, 60, 70 or 80 Ncm. The ?max and the maximum principal strain (max) were obtained for cortical and cancellous bone. Pearson's correlation test was used to determine the correlation between insertion torque and stress concentration in the periimplant bone tissue. The results showed that traumatic occlusion and increasing C/I ratio significantly increased the stress concentration in cortical bone, cancellous bone, implant and prosthetic screw. The prosthetic retention system significantly influenced the stress concentration, but at a lower level than the C/I ratio or occlusal loading. The screw-retained prosthesis displayed higher stress levels than the cement-retained prosthesis in all components. The stress concentration was not affected by the restorative material. For the second objective, the increase in the insertion torque generated an increase in the ?max and ?max values for cortical and cancellous bone. It is concluded that occlusion is main factor that most influences the stress concentration at the implant prosthodontic supported by short and high insertion torques that increase concentrations of stress and strain in the peri-implant bone tissue / Doutorado / Protese Dental / Doutor em Clínica Odontológica

Page generated in 0.0757 seconds