• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 568
  • 164
  • 20
  • 18
  • 18
  • 17
  • 17
  • 11
  • 10
  • 9
  • 9
  • 8
  • 4
  • 4
  • 2
  • Tagged with
  • 815
  • 815
  • 518
  • 484
  • 154
  • 137
  • 127
  • 114
  • 101
  • 85
  • 80
  • 77
  • 75
  • 74
  • 60
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
491

Planejamento do tamanho do implante dentário utilizando imagens de radiografia panorâmica digital e tomografia computadorizada de feixe cônico

Correa, Leticia Ruhland January 2012 (has links)
O objetivo deste estudo foi comparar o tamanho do implante dentário (largura e comprimento) planejado utilizando-se radiografias panorâmicas digitais (D-pan), reconstruções panorâmicas geradas a partir de Tomografia Computadorizada de Feixe Cônico (TCFC-pan), e imagens transversais de Tomografia Computadorizada de Feixe Cônico (TCFC-transversais), em quatro sistemas de implantes. Para tal, foram avaliados 103 sítios de implantes unitários nas regiões de pré-molares superiores e molares inferiores em 71 pacientes. Em cada paciente foram realizadas uma radiografia panorâmica digital (D-pan) e uma Tomografia Computadorizada de Feixe Cônico (TCFC). Para a realização da D-pan, foi colocada uma esfera de metal de 5 mm de diâmetro na região edêntula para que fosse realizada a calibração linear da imagem. Os dados adquiridos nas TCFC foram reconstruídos em imagens panorâmicas de 10 mm de espessura (TCFC-pan) e em imagens transversais de 1 mm de espessura (TCFC-transversais). Foram realizadas medidas em todas as imagens. Todas as modalidades de imagem foram exibidas no mesmo monitor e avaliadas por três observadores que utilizando o programa PorDios, identificaram quatro pontos de referência no espaço disponível e delimitaram o sítio de implante. Os tamanhos (largura e comprimento) dos implantes foram comparados entre as três modalidades de imagem e as diferenças foram analisadas. Utilizando o software SPSS, foi selecionado o tamanho do implante mais próximo (igual ou menor) que serviria no espaço disponível, baseado nos tamanhos existentes nos quatro sistemas utilizados (Nobel Biocare, Straumann, 3i e Neodent). O tamanho do implante selecionado nas imagens TCFC transversais foi comparado com o tamanho do implante selecionado nas outras duas modalidades (D-pan e TCFC-pan), para cada um dos sistemas separadamente. Como resultado, na maioria das vezes, o tamanho do implante foi menor nas TCFC-transversais, do que quando comparado com D-pan e TCFC-pan. Houve diferença significativa na largura do implante nas regiões de pré-molares entre D-pan e TCFC-pan. O implante foi significantemente mais curto na TCFC-transversal do que na D-pan, nas regiões de molares. A maioria das mudanças ocorreu para um tamanho mais fino e mais curto, que resultou em um tamanho de implante significantemente menor nas TCFC-transversais. Os resultados permitem concluir que quando o implante é planejado utilizandose imagens transversais de TCFC este é selecionado em um tamanho mais fino e mais curto do que quando idealizados em radiografias panorâmicas digitais. / The objective of this study was to compare the implant size (width and length) planned with digital panoramic radiographs, CBCT-generated panoramic views, or CBCT cross-sectional images, in four implant systems. Seventy-one patients with a total of 103 single-unit implants in the upper premolar and/or lower molar regions were examined with digital panoramic radiography (D-PAN) and cone beam computed tomography (CBCT). A 5-mm in diameter metal ball was placed in the edentulous area for the D-PAN. CBCT data sets were reformatted to a 10-mm thick CBCT panoramic view (CBCT-pan) and 1-mm cross-sections (CBCT-cross). Measurements were performed in the images using dedicated software. All images were displayed on a monitor and assessed by three observers who outlined a dental implant by placing four reference points in the site of the implant-to-be. Differences in width and length of the implant-to-be from the three modalities were analyzed. An automated program selected the implant size, which was the closest (smaller or equal) size implant that would fit the measured size, based on the sizes available in four worldwide-used implant systems (Nobel Biocare, Straumann, 3i and Neodent). The implant size selected in the CBCT-cross images was then compared to that selected in the other two modalities (D-PAN and CBCT-pan) for each of the implant systems separately. The implant-to-be (average measurements among observers) was narrower when measured in CBCT-cross compared with both D-PAN and CBCT-Pan. For premolar sites, width also differed significantly between D-PAN and CBCT-pan modalities. The implant-to-be was also significantly shorter when recorded in CBCT-cross than in D-PAN. In premolar sites there were no significant differences in implant length among the three image modalities. It mattered very little for the change in implant step sizes whether CBCT-cross was compared to D-PAN or CBCT-pan images. Our results show that the selected implant size differs when planned on panoramic or cross-section CBCT images. In most cases implant size measured in crosssection images was narrower and shorter than implant size measured in a panoramic image or CBCT-based panoramic view.
492

Avaliação da adaptação marginal em pilares pré-fabricados e das tensões transmitidas a implantes por infra-estrutura metálica em viga I em função da inclinação dos implantes distais e do número de pilares / Fit evaluation on prefabricated abutments and transmitted stress to implants by I beam superstructures as a function of implants number and distal angulations

Karina Albino Lencioni 14 December 2011 (has links)
A ausência do perfeito ajuste e o assentamento passivo dos pilares sobre implantes podem provocar tensões inadequadas na interface de osseointegração, possibilitando problemas mecânicos e biológicos. A fotoelasticidade é uma técnica experimental para análise de tensões capaz de produzir resultados confiáveis e fiéis aos parâmetros clínicos. Assim, este estudo teve como objetivos avaliar por meio de microscopia ótica a adaptação marginal entre pilares intermediários tipo mini pilar cônico e a estrutura metálica com desenho geométrico em viga I fundida com liga de cobalto-cromo (CoCr). Analisaram-se, também, por meio de fotoelasticidade, as tensões geradas ao redor dos implantes por essa mesma estrutura metálica quando submetida a cargas estáticas em função da variação do número de pilares (4 ou 5) e da inclinação dos implantes distais (para o modelo de 5 implantes). As análises foram feitas antes e após o seccionamento das barras e soldagem a laser. Foram obtidas dez infraestruturas em viga I, fundidas em monobloco, utilizando-se liga de cobalto cromo. A análise da adaptação marginal foi realizada em estereomicroscópio sob aumento de 20X. Modelos fotoelásticos para 4 ou 5 implantes foram confeccionados e realizada a mensuração da tensão ao redor dos implantes. As barras foram seccionadas e soldadas por laser e novas medidas de adaptação marginal foram realizadas, bem como foram confeccionados novos modelos fotoelásticos para as estruturas soldadas. A análise da passividade das vigas I em monobloco não se mostrou estatisticamente significante (p≤0,05), a passividade no pilar oposto foi sempre menor que a do pilar parafusado antes e após a soldagem a laser, não houve diferença estatística no desajuste vertical entre as vigas I para quatro e cinco implantes, antes e após a soldagem a laser. A soldagem a laser gerou maior passividade e menor desajuste vertical nas vigas I. A análise fotoelástica mostrou que a soldagem a laser ocasionou menor tensão nos implantes quando não há aplicação de carga na viga I para quatro implantes, mas aumentou a tensão em viga I para cinco implantes. Assim, pode-se concluir que a soldagem a laser gerou maior passividade e menor desajuste vertical entre os pilares e o implante, e menor tensão ao redor dos implantes em vigas I de quatro implantes, e maior tensão em viga I para cinco implantes. / The absence of perfect fit and passivity on implants can cause stress on the osseointegration interface, enabling biomechanical problems. Photoelasticity is an experimental technique for stress analysis can produce reliable results and faithful to clinical parameters. Thus, the aim of this study was to assess by light microscopy the marginal adaptation of mini pillar intermediate and superstructure with geometric design I beam with cast cobalt-chromium (CoCr). It was analyzed also by means of photoelasticity, the tensions generated around the implants by the same metal superstructure when subjected to static loads due to the variation in the number of implants (4 or 5) and tilting the distal (for model 5 implants). Analyses were made before and after sectioning of the bars and laser welding. It was obtained ten I-beam superstructure I, cast in cobalt chromium alloy. The analysis of marginal adaptation was performed in a stereomicroscope under magnification 20X. Photoelastic models for 4 or 5 implants were made and carried out the measurement of the tension surrounding the implants. The bars were cut and welded by laser and marginal adaptation of new measures were taken and new photoelastic models were made for welded structures. The analysis of the passivity of the I-beams in a single block was not statistically significant (p≤0.05), passivity on the pillar opposite was always less than the abutment screws before and after laser welding, there was no statistical difference in the vertical misfit between I-beams for four and five implants before and after laser welding. The laser welding has generated greater passivity and lower beams in vertical misfit I. The photoelastic analysis showed that laser welding caused less stress on the implants when there is no application of load over four implants, but increased the tension for five implants. Thus, it can be concluded that laser welding generated more passivity and less vertical fit between the pillars and the implant, and less tension around the implants in four implants, and higher stress for five implants.
493

Análise qualitativa e quantitativa, pelo método dos elementos finitos, da distribuição de tensão em diferentes rebordos reabilitados com próteses metalocerâmicas sobre implantes do tipo cone Morse, de diferentes comprimentos / Qualitative and quantitative analysis by finite element method of the stress distribution at different bony edges rehabilitated with Morse taper implant- supported metalloceramic prostheses, of different lengths

Marcelo Bighetti Toniollo 16 December 2011 (has links)
O emprego dos implantes osseointegráveis na odontologia moderna tem sido crescente. Dentre os tipos de conexões existentes, o cone Morse tem se mostrado com vantagens e atrativos interessantes. Com relação ao comprimento, a aplicabilidade de implantes curtos para casos de perda óssea vertical intensa se faz muito presente, principalmente em áreas mandibulares posteriores, a fim de se evitar procedimentos cirúrgicos mais complexos que envolvam maior morbidade. Juntamente com a perda óssea, a necessidade da manutenção do plano oclusal nivelado é inquestionável, sendo necessário o uso de próteses sobre implantes curtos com dimensões maiores, podendo haver sobrecarga sobre tais implantes e estruturas de suporte. O método dos elementos finitos (MEF) possibilitou avaliar as tensões na superfície dos implantes e componentes, e na interface entre implantes e rebordo ósseo. Neste estudo foram usados modelos de implantes cone Morse e próteses sobre implantes do tipo metalocerâmicas, individualizadas, de diferentes dimensões, alojados em diferentes rebordos com reabsorção óssea vertical. Todas as estruturas foram desenhadas por meio do programa SolidWorks (SolidWorks Corporation, Massachusetts, USA), e análises qualitativas e quantitativas das tensões equivalentes de Von Mises foram realizadas nos rebordos ósseos e implantes por meio do programa AnsysWorkbench10.0 (Swanson, Analysis Systems, Inc., Houston, USA). Os grupos foram: grupo controle (3 implantes de 11mm comprimento), grupo 1 (implantes de 13mm, 11mm e 5mm comprimento), grupo 2 (1 implante de 11mm e 2 implantes de 5mm comprimento) e grupo 3 (3 implantes de 5mm comprimento). As alturas dos pilares usados foram 3.5mm para implantes de 13mm e 11mm (regulares) e 0.8mm para implantes de 5mm (curtos). Foram simuladas forças oblíquas de 365N em molares e 200N em pré-molares. Os resultados mostraram que, com relação aos implantes e componentes, os pilares com 0.8mm de altura geraram menores tensões equivalentes de Von Mises comparativamente aos de 3.5mm de altura. A associação de implantes curtos com coroas de maiores dimensões concentrou maiores valores e distribuição de tensões na superfície destes implantes, principalmente na face vestibular (direção das cargas oblíquas). O implante mais distal sempre concentrou maiores tensões. Já com relação ao osso, houve 50% mais tensão no osso cortical para os implantes de 5mm do que os de 13mm e 11mm de comprimento. Houve 80% mais tensão no osso esponjoso para os implantes de 5mm do que os de 13mm e 11mm de comprimento. Houve maior concentração de tensão na região óssea cervical aos implantes curtos. No entanto, tais implantes foram capazes de realizar boa dissipação das tensões aos ossos frente às cargas aplicadas, apesar de atingir seu limiar próximo entre deformação elástica e plástica para o osso trabecular. Implantes mais distais e/ou com maior mesa oclusal geraram regiões de maior tensão no osso circunjacente. Concluiu-se que pacientes que se faz necessária a instalação de implantes curtos associados a próteses sobre implantes de dimensões aumentadas necessitam de cuidadosa avaliação e ajuste oclusal, já que uma eventual sobrecarga nestes implantes curtos, e até mesmo nos de comprimento regular, podem gerar tensões que vão além do limiar fisiológico do osso circunjacente, podendo acarretar danos a todo o sistema. / The use of dental implants is increasing in dentistry. Among the different types of connections existent, the Morse taper has been highlighted on several positive features. Regarding to the length, the use of short implants in cases of severe vertical bone loss are becoming frequent, especially in mandibular posterior areas, avoiding more complex surgical procedures and greater morbidity. As a consequence of bone loss, the need for rehabilitation to maintain the occlusal plane level is unquestionable, leading to the use of implants prostheses with larger dimensions, which may cause overload on these short implants and the supporting structure. This finite element analysis (FEA) compared stress distribution on external surface of Morse taper implants, their abutments and at bone/implant interface of different bone ridges, varying implants length and dimensions of each metal-ceramic crowns. All structures were designed using the SolidWorks software (SolidWorks Corporation, Massachusetts, USA), and qualitative and quantitative analysis of the equivalent Von Mises stresses were ran on AnsysWorkbench10.0 (Swanson Analysis Systems, Inc., Houston, USA). Three-dimensional FE models were designed representing a posterior left side segment of the mandible: group control, 3 implants of 11mm length; group 1, implants of 13mm, 11mm and 5mm length; group 2, 1 implant of 11mm and 2 implants of 5mm length; group 3, 3 implants of 5mm length. The abutments heights were 3.5mm for 13mm and 11mm implants (regular) and 0.8mm for 5mm implants (short). Evaluation was performed on Ansys software, with oblique loads of 365N for molars and 200N for premolars. The results, for implants and abutments, showed that abutments with 0.8mm height generated less von Mises stresses compared with 3.5mm height. The use of short implants associated with bigger crowns concentrated higher stress distribution and stress values on the surface implants, mainly on the vestibular side (oblique loads). The more distal implants had the higher stress mesures. The results for the bone showed that there was 50% higher stress on cortical bone on the 5mm implants length than 13mm and 11mm implants. There was 80% higher stress on trabecular bone for the 5mm implants length than 13mm and 11mm implants. There was higher stress concentration on the bone region of the short implants neck. However, these implants were capable to dissipate the stress to the bones, given the applied loads, but achieving near the threshold between elastic and plastic deformation to the trabecular bone. Distal implants and/or with biggest occlusal table generated greatest stress regions on surrounding bone. It was concluded that patients requiring short implants associated with increased proportions implant prostheses need careful evaluation and occlusal adjustment, as a possible overload in these short implants, and even in regular ones, can generate stress beyond the physiological threshold of the surrounding bone, which may compromise the whole system.
494

Análise retrospectiva de 129 implantes osseointegráveis de ancoragem zigomática utilizados na reabilitação de maxilas severamente reabsorvidas em protocolo de dois estágios em um período de 7 anos / Retrospective analysis of 129 consecutive zygomatic implants applied for rehabilitation of severely resorbed maxilla in a double-stage protocol in a period of 7 years

Rafael Tajra Evangelista Araújo 21 January 2016 (has links)
Este estudo tem como objetivo apresentar uma análise retrospectiva de dados contidos em prontuários de atendimento, sobre a evolução clínica de 129 implantes zigomáticos colocados no seio maxilar de 37 pacientes com maxila desdentada severamente reabsorvida (total ou parcialmente), os quais foram reabilitados através da instalação de implantes zigomáticos pela equipe de Cirurgia e Traumatologia Buco-Maxilo-Facial da Faculdade de Odontologia de Ribeirão Preto (FROP-USP), durante o período março/2007 à novembro/2014. Todos os pacientes incluídos no estudo foram tratados usando o mesmo protocolo cirúrgico, técnica ´´sinus slot´´ modificado por Stella. A análise foi direcionada a registro de dados relativos as seguintes variáveis: gênero, idade, raça, história médica, etiologia, vícios, grau de atrofia óssea, tipo e tamanho dos implantes zigomáticos, número de implantes colocados, reabilitação protética, a taxa de sobrevivência e de sucesso dos implantes, além das complicações. Os indivíduos foram acompanhados por meio de exames clínicos e de tomográficos padronizados. O critério de inclusão dos prontuários na amostra foram de pacientes submetidos a esse tipo de tratamento, com preenchimento completo de informações e de possuírem o Termo de Consentimento Livre e Esclarecido. Os dados coletados por um único examinador foram transportados para uma planilha eletrônica utilizando o programa Microsoft Excel, sendo realizada neste momento uma análise descritiva dos resultados. Trinta e sete pacientes consecutivos (25 mulheres, 12 homens; média de idade de 55,64 anos [variação: 40-77 anos]) foram tratados. Todos estavam em necessidade de reabilitação bucal e tinham atrofia maxilar severa com indicação para a colocação de implantes zigomáticos. Cento e vinte e nove implantes zigomáticos foram colocados nesses 37 pacientes. Dois dos 129 implantes falharam, resultando em uma taxa de sucesso de 98,44%, com esses dados de acompanhamento. Sinusite do seio maxilar foi a ocorrência mais comum (21,62%) entre as complicações encontradas. No entanto, entre os implantes que falharam, nenhum foi relacionado com sinusite ou fumo. Concluímos que tratamento com implantes zigomáticos representa uma opção previsível para reabilitação da maxila atrófica desdentada. No entanto, mais estudos são necessários para se relacionar diretamente esses implantes com a sinusite, que apresenta uma elevada prevalência nestes casos. / This study aims to present a retrospective analysis of data contained in patient records on the clinical course of 129 zygomatic implants placed in the maxillary sinus of 37 patients with severely resorbed edentulous maxilla (fully or partially), which were rehabilitated by installing of zygomatic implants by staff of Surgery and Traumatology Oral and Maxillofacial Ribeirão Preto Dental School (FROP-USP), during the period from March/2007 to November/2014. All patients included in the study were treated using the same surgical protocol, \'\'sinus slot\'\' modified by Stella technique. The analysis was aimed at data record the following variables: gender, age, race, medical history, etiology, addictions, degree of bone atrophy, type and size of zygomatic implants, number of placed implants, prosthetic rehabilitation, the survival rate and success of the implant, in addition to complications. The subjects were followed through clinical and standardized CT. The criterion for inclusion of the records in the sample were patients undergoing this type of treatment, with complete filling of information and possess the Informed Consent and Informed. The data collected by a single examiner were transported to a spreadsheet using Microsoft Excel program, being carried out at present a descriptive analysis of the results. Thirty-seven consecutive patients (25 women, 12 men; mean age of 55.64 years [range, 40-77 years]) were treated. All were in need of oral rehabilitation and had severe jaw atrophy indicated for the placement of zygomatic implants. One hundred and twenty-nine zygomatic implants were placed in these 37 patients. Two of the 129 implants fail, resulting in a success rate of 98.44%, with these tracking data. Maxillary sinus sinusitis was the most common event (21.62%) among the complications found. However, between implants that have failed, none has been associated with sinusitis or smoke. We conclude that treatment with zygomatic implants is a predictable option for rehabilitation of edentulous atrophic maxilla. However, more studies are needed to relate directly with these implants sinusitis, which has a high prevalence in these cases.
495

O bombardeamento da superfície de titânio com íons de argônio influencia a resposta biológica de pré-osteoblastos / Argon ions bombardment of titanium surface influences preosteoblastic biological behavior

Carlos Eduardo Bezerra de Moura 14 December 2007 (has links)
As propriedades da superfície do implante têm papel crítico na indução das respostas celulares necessárias para o sucesso do implante. Os objetivos deste trabalho foram investigar o efeito do bombardeamento com íons de argônio sobre a superfície de titânio comercialmente puro (TiCP) e sua influencia na interação célula-superfície. Superfícies bombardeadas e lisas foram avaliadas quanto à topografia, rugosidade e molhabilidade. Ensaios de adesão, proliferação, atividade de fosfatase alcalina (ALP) e expressão de osteocalcina (OC) foram conduzidos usando células MC3T3-E1 cultivadas sobre essas duas diferentes superfícies. Os níveis de rugosidade na superfície bombardeada e lisa foram 0,11µm and 0,027µm, respectivamente. A Microscopia eletrônica de Varredura (MEV) e Microscopia de força atômica (AFM) também revelaram rugosidade uniforme nestas amostras. A molhabilidade foi maior na superfície bombardeada. O número de células aderidas (30 e 60 min) foi significativamente maior sobre a superfície bombardeada. A proliferação celular depois de 3 e 7 dias também foi maior na superfície bombardeada. A atividade de ALP e expressão de OC não apresentaram diferença significativa entre as superfícies. Esses dados nos levam a propor que a técnica processamento a plasma em atmosfera de argônio com uso de cátodo planar é uma excelente ferramenta para obtenção de biomateriais que favoreçam a osseointegração. / Titanium surfaces were modified by argon ions bombardment aiming to evaluate the influence of the treatment on cell-surface interaction. The effects of topographic (roughness, microstructure) and physiochemical (wettability - contact angle) parameters on the morphology, adhesion, proliferation and MC3T3-E1 preosteoblasts differentiation were analyzed. No-treated surfaces (smooth) were used as a control. The levels of roughness observed in bombarded and smooth titanium surfaces were of 0.11µm and 0.027µm respectively. Scanning electron microscopy (SEM) and atomic force microscopy (AFM) analysis showed that the roughness distribution was uniform. The wettability increased in treated surfaces. The number of attached cells (30 and 60min) was significantly higher on the bombarded surface, as well as, cell proliferation after 3 and 7 days was also significantly higher on ion-bombarded surface. The ALP activity and OC expression did not show not significant differences between the surfaces. Based on the results showed one can propose that the bombardment of titanium surfaces with argon ions is an excellent procedure for obtaining biomaterials and improve the osseointegration.
496

Avaliação histológica e microtomográfica comparativa entre o aloenxerto ósseo liofilizado e o aloenxerto ósseo congelado para preenchimento na elevação do assoalho de seio maxilar / Histological and microtomografic assessment between lyophilized and fresh-frozen allogenic bone grafts for sinus lifting : Randomized Controlled clinical Trial

Marcello Roberto Manzi 15 September 2016 (has links)
O aloenxerto ósseo desmineralizado irradiado (ALD) e o aloenxerto ósseo congelado mineralizado (ACM) são alternativas ao osso autógeno para o aumento do rebordo ósseo alveolar. Individualmente, já foram testados quanto a eficiência, de certa forma, comparável aos autógenos e suas vantagens sobre eles. Entretanto, não há estudos padronizados comparando o desempenho clínico entre esses dois tipos de aloenxertos, quando utilizados em região de maxila atrófica para instalação e implantes. O objetivo deste estudo foi realizar um ensaio clínico randomizado controlado que envolve a elevação bilateral do seio maxilar empregando o osso alógeno liofilizado desmineralizado irradiado (ALD) ou o osso alógeno congelado mineralizado (ACM) e verificar comparativamente os desfechos clínicos para estabilidade de implantes, quantidade e qualidade de neoformação óssea. Dez pacientes foram submetidos a cirurgia de elevação do seio maxilar bilateral na qual foi utilizado um dos tipos de aloenxerto, de forma randômica em um dos lados. Seis a nove meses após o aumento do rebordo ósseo, no momento da instalação de implantes osseointegrados, foram obtidas amostras ósseas por meio de trefina de 2x10mm para análises microtomográficas e histológicas. A estabilidade dos implantes foi aferida por frequência de ressonância em dois momentos, imediato e após 6 meses da instalação dos implantes. Os resultados mostraram aumento do rebordo, radiograficamente detectável em todos os pacientes e grupos. Os implantes osseointegrados, inseridos em enxertos ACM, apresentaram melhor estabilidade primária, embora o acréscimo de estabilidade tenha sido mais significativo no ALD. As análises microtomográficas e histológicas revelaram mais formação óssea de melhor qualidade nos ALD do que nos ACM. Não houve resposta a corpo estranho para nenhum dos tipos de aloenxertos. Notou-se mais quantidade de material remanescente para ACM do que para ALD. Concluímos que os aloenxertos liofilizados desmineralizados irradiados (ALD) apresentaram melhor desempenho quanto aos parâmetros estudados. / Demineralized bone irradiated allograft (DFDBA) and fresh- frozen (FF) are alternative grafts to autogenous bone in alveolar ridge augmentation. Individually, these allografts have been tested for their efficiency, in a way comparable to autogenous, and so their advantages over autogenous grafts. However, there are no standardized clinical studies comparing the clinical and histological performance between these two allografts in atrophic maxilla bone augmentation for implants instalment. The aim of this study was to perform a randomized controlled clinical trial involving bilateral sinus floor elevation employing demineralized freeze-dried irradiated allograft (DFDBA) or fresh-frozen (FF) and to compare clinical and histological outcomes for stability of implants, quantity and quality of bone formation. Ten patients underwent bilateral maxillary sinus lifting surgery in which side was randomly used one of those allografts for alveolar ridge augmentation. Six to nine months after grafting, at the time of dental implants instalment, trephine 2x10mm bone core biopsies were obtained to micro computed tomographic and histological analyses. The stability of the implants was measured by resonance frequency in two stages, immediately and 6 months after implants installation. Results showed that there was an increase, radiographically detectable, in all patients and groups. The dental implants inserted in FF grafts showed better primary stability but implant stability, lately, increased significantly in DFDBA. Micro tomographic and histological analyses revealed that bone formation amount and quality was superior in DFDBA than in FF. There was no foreign body response for any of the allografts. There was a greater amount of persisting graft-materialin FF than in DFDBA. We conclude that demineralized freeze-dried irradiated allograft (DFDBA) presented a superior performance than mineralized FF.
497

Extrusão inversa de pequenas peças em titânio GR 4 para implantes dentários - ferramenta e processo

Bilessimo, Luciano Dagostin January 2012 (has links)
Este trabalho tem como objetivo geral avaliar o comportamento do processo de extrusão inversa para produzir pequenas peças em titânio puro CP grau 4 e promover a fabricação de uma pré forma visando o implante dentário modelo cone morse. Inicialmente, analisou-se o contexto da implantologia, identificando-se o problema da pesquisa. Em seguida, levantou-se um referencial bibliográfico sobre conformação mecânica, extrusão inversa, implantes dentários e titânio. Diante deste contexto, foi executado um planejamento experimental. Estudos preliminares da matéria-prima foram realizados para caracterização do material a ser conformado. Foi desenvolvida uma ferramenta para conformação por extrusão inversa a frio. As atividades relacionadas à alteração do fator do tamanho de grão e parâmetros definidos no equipamento como a velocidade e diâmetro do punção, estabeleceram as variáveis independentes no ensaio. Após realização dos experimentos, dados de dureza, fibramento e força de extrusão foram coletados e analisados estatisticamente. Finalmente, a partir da análise da peça extrudada, observou-se a viabilidade do uso da conformação a frio do titânio em pequenas peças, obtendo-se boa precisão dimensional e controle operacional. / This study aims at evaluating the behavior of indirect extrusion process to produce small parts in pure titanium grade 4 CP and manufacture a preform targeting dental implant model morse taper. Initially, the context of implantology was analyzed, identifying the research problem. Bibliographic reference on metal forming, extrusion inverse, dental implants and titanium was performed. Given this context, an experimental design was executed. Preliminary studies of the feedstock were carried out to characterize the material to be shaped. A tool for inverse cold extrusion was developed. Activities related to the change in grain size and parameters defined in the equipment and the speed and diameter of the punch, established the independent variables in the experiment. After finish of the experiments, data of hardness, grain flow and extrusion force were collected and analyzed statistically. Finally, from the analysis of extruded piece was observed feasibility of using cold forming of titanium in small pieces with good dimensional accuracy and operational control.
498

Osseointegração de implantes após levantamento de assoalho do seio maxilar com osso bovino inorgânico : estudo clínico, radiográfico e histológico / Osseintegration of implants after lifting the maxillary sinus floor with inorganic bovine bone : a clinical, histological and histomorphometrical analysis

Stagnaro, Gonzalo Borgia January 2013 (has links)
Introdução: os fenômenos envolvidos durante o processo de reparo após elevação do assoalho do seio maxilar, relacionados ao uso de enxertos e biomateriais, não são completamente conhecidos. Objetivos: avaliar clínica, radiológica e histomorfometricamente os resultados de neoformação óssea e desempenho de implantes inseridos em sítios previamente reconstruídos por meio de cirurgia de elevação do assoalho do seio maxilar utilizando osso bovino inorgânico, verificando se há correlação entre os mesmos. Metodologia: a amostra consistiu em 20 implantes inseridos após 7 a 11 meses, em 20 sítios de 10 pacientes adultos, consecutivamente, submetidos à cirurgia de levantamento do assoalho do seio maxilar e enxerto de osso bovino inorgânico. No momento da inserção do implante foi coletada uma amostra de tecido ósseo no sitio da perfuração, para a realização da histomorfometria. O sucesso dos implantes foi avaliado por critérios clínicos decorridos quatro meses de sua inserção. A densidade radiográfica das radiografias periapicais prévias à instalação de 13 dos implantes foi medida e correlacionada aos dados histomorfométricos e de sucesso. Resultados: um implante foi perdido. A porcentagem media de osso vital foi de 50.06%, a de não vital de 40.17%, e de tecido mole de 9,44%. Houve correlação positiva entre a densidade radiográfica e a quantidade de osso vital, e negativa entre esta e a quantidade de tecido mole. Não houve correlação entre o sucesso dos implantes e os demais achados. Conclusões: a cirurgia de elevação do seio maxilar mostrou-se segura a eficaz, permitindo inserção de implantes nos períodos citados. A radiografia periapical digitalizada apresentou potencial para estimar o percentual de osso vital após este tipo de procedimento. / Introduction: healing process after sinus floor elevation using biomaterials is not fully understood. Objectives: clinical, radiological and histomorphometric evaluation of healing, as well as implant results on previously sinus lift implant sites using inorganic bovine graft, testing for correlation between variables. Methods: 20 implants inserted after 7 to11 months, on 20 sitesof 10 adult consecutive patients,indicated for sinus floor elevation using inorganic bovine graft composed the study sample. On implant insertion a bone sample was trefined from implant site, for histomorphometry. Implant success was evaluated by clinical criteria 4 months after insertion. Radiographic density was measured before implant insertion on 13 sites and correlated to success and histomorphometric data. Results: one implant was lost. Vital bone was present on 50.06% of the sample areas, non vital on 40.17% and soft tissue one 9,44%. There was positive correlation between radiographic density and vital bone area, as weel as negative correlation with soft tissue area. There was not correlation between implant success and the other data. Conclusions: sinus lift presented as a safe and efficient treatmenta alternative for implant placement, on the healing periods described. Periapical radiography showed potential to estimate the vital bone and soft tissue formation after sinus lift using this kind of graft.
499

Avaliação da união entre o componente protético e a conexão interna tipo cone morse do implante dentário

Gois Filho, Derivaldo Moura 27 February 2015 (has links)
The biomechanical aspects related to the adaptation of fixed prostheses over implants are directly associated to treatment success. Therefore, the aim of this study was to evaluate the presence of microgaps in the union formed by the abutment and the inner connection of Cone Morse dental implant. The study was composed by two groups. The first group (n:16) used materials (dental implant and abutment) of the same manufacturer, Neodent® (Curitiba-PR, Brazil). The second group (n:16) used materials from different manufacturers, where the dental implant was Neodent® (Curitiba-PR, Brazil), and the abutment was Singular®(Parnamirim-RN, Brazil). The sets were sent to scanning electron microscope (SEM), where it was taken the measurements of microgaps formed between the implant connection and the abutment. The results obtained were submitted to statistical (Mann-Whitney-U) evaluating dispersion measurements and central tendency of values (standard and mean deviation). In group 1 the average found was 5,69μm and standard deviation (SD) was 8,46μm. Group 2 showed average of 1,24μm and SD: 0,44μm. The group formed by dental implant and abutment from the same manufacturer showed a greater data dispersion, with greater microgap values, compared to the group formed by the set implant-abutment of different manufacturers. It was concluded that, based on the measurements taken on SEM, the group formed by implant and abutment of different manufactures showed lower values of microgaps, and, therefore, a better in vitro adaptation. / Os aspectos biomecânicos relacionados à adaptação da prótese sobre o implante dentário estão diretamente associados ao sucesso do tratamento. Assim, o objetivo deste trabalho foi avaliar a presença de microgaps na união formada pelo abutment e a conexão interna do implante dentário do tipo Cone Morse. O estudo foi composto de dois grupos onde no primeiro grupo (n:16) foram utilizados materiais (implante dentário e abutment) do mesmo fabricante, Neodent® (Curitiba-PR, Brasil). No segundo grupo (n:16) foram utilizados materiais de fabricantes diferentes, sendo o implante da marca Neodent® (Curitiba-PR, Brasil) e o componente protético da marca Singular®(Parnamirim-RN, Brasil). Os conjuntos foram levados ao microscópio eletrônico de varredura (MEV), sendo realizadas as mensurações do microgap formado entre a conexão do implante e o componente protético. Os resultados obtidos foram submetidos à análise estatística (Mann-Whitne-U) avaliando-se medidas de dispersão e tendência central dos valores (desvio padrão e média). No grupo 1 a média encontrada foi de 5,69μm e o desvio padrão (DP) foi de 8,46μm. O grupo 2 apresentou média de 1,24μm e o DP: 0,44μm. O grupo formado por implante e componente protético do mesmo fabricante apresentou maior dispersão dos dados, com valores maiores para o microgap, comparando-se com o grupo formado pelo conjunto implante-abutment de marcas diferentes. Concluiu-se que, com base nas mensurações realizadas no MEV, o grupo formado por implante e abutment de diferentes fabricantes apresentou menores valores de microgap e consequentemente uma melhor adaptação in vitro.
500

Distribuição de tensões e resistência mecânica de infraestruturas de cobalto-cromo sobre implantes após soldagem a Laser e TIG / Stress distribution and mechanical strength of chrome-cobalt framework on implanta after laser or TIG welding

Castro, Gabriela Cassaro de, 1986- 02 October 2011 (has links)
Orientador: Mauro Antonio de Arruda Nóbilo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-17T15:56:25Z (GMT). No. of bitstreams: 1 Castro_GabrielaCassarode_M.pdf: 1780672 bytes, checksum: 8af543ab2352bb5187bc910fb554c95d (MD5) Previous issue date: 2011 / Resumo: A passividade e a resistência mecânica dos cantiléveres são fatores importantes na avaliação do comportamento biomecânico das próteses implantossuportadas. A proposta neste estudo foi avaliar a influência de três diferentes técnicas de confecção de estruturas implantossuportadas em liga de Co-Cr quanto à passividade e resistência mecânica, por meio de análise fotoelasticidade e teste de resistência à flexão, respectivamente. A partir de uma matriz de aço simulando uma mandíbula edêntula com 4 análogos de implantes hexágono externo com plataforma regular, foi obtido o modelo de trabalho. Sobre este modelo cinco estruturas foram confeccionadas para cada grupo: estruturas em monobloco, soldadas a TIG e a Laser. O modelo fotoelástico foi confeccionado com resina epoxi flexível (GIII, Polipox Indústria e Comércio Ltda, São Paulo). Na análise fotoelástica, as estruturas foram aparafusadas no modelo para a verificação da tensão cisalhante máxima em 34 pontos selecionados ao redor dos implantes e 5 pontos na região mediana do modelo. Foram avaliadas as tensões em todo o modelo fotoelástico, entre as regiões direita, esquerda e central e ainda, entre a região cervical e apical. O teste de resistência à flexão foi realizado em uma máquina de ensaios mecânicos Instron (Instron Co., Canton, Mass.). Os valores foram submetidos à analise de variância para dados com dois fatores de estudo (ANOVA 2-Way), seguidos pelo teste de Tukey para comparação entre as médias. Os resultados não apresentaram diferença significante entre as tensões presentes nos grupos e áreas estudadas. Para o teste mecânico as estruturas em monobloco foram mais resistentes que as soldadas a Laser, que por sua vez, foram mais que as soldadas a TIG. Concluiu-se que as tensões geradas ao redor dos implantes foram semelhantes entre as diferentes técnicas de confecção, e entre todas as regiões analisadas. E as estruturas em monobloco apresentaram melhor resistência, seguida das soldadas a Laser. / Abstract: Passive fitting frameworks and cantilever¿s mechanical strength are important aspects in implant fixed prostheses biomechanical behavior. The proposal of this study was to evaluate the passivity end mechanical strength of tree different Co-Cr alloy framework manufactured technique, by photoelasticity analysis and flexural strength test. In a curved steel matrix, simulating an edentulous mandible, four external hexagon with regular platform implant analogs were positioned. Five frameworks for each group were obtained: one-piece cast, TIG welding and Laser welded frameworks. The photoelastic model was made from flexible epoxy resin (GIII, Polipox Industry e Comerce Ltda, Sao Paulo). To photoelastic analysis, the frameworks were bolted on the model and seventeen points around the implants were selected for right and left regions, to measure the maximum shear stress. At the middle area, 5 points on the medium of the model, was measured. Were evaluated the stress generated around all the implants in the photoelastic model, around implants in selected area (right, left and middle), and the stress on the cervical and apical model¿s area. The frameworks were submitted to flexural strength test in an Instron machine (Instron Co., Canton, MA, USA). The data were statistically analyzed using a 2-way analysis of variance (ANOVA) and Tukey test. The results showed no significant difference between any evaluated groups or areas. In the flexural strength test, one-piece frameworks were more resistant than Laser welded, which were more resistant than the TIG welded. In conclusion, the stresses around the implants were similar among the different framework manufacturing techniques and among all evaluated areas. And one-piece casting framework showed better resistance, followed by Laser welded and TIG welded frameworks. / Mestrado / Protese Dental / Mestre em Clínica Odontológica

Page generated in 0.088 seconds