Spelling suggestions: "subject:"denture complete"" "subject:"centure complete""
51 |
Efeito da termociclagem e do citrato sobre a deformação permanente e resistencia a tração da união de um reembasador resiliente unido a resina acrilicaNakaoka, Marcia Mika 28 February 2005 (has links)
Orientador: Marcelo Ferraz Mesquita / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-04T03:47:43Z (GMT). No. of bitstreams: 1
Nakaoka_MarciaMika_M.pdf: 3146053 bytes, checksum: a03bb35599db030272585c8a34b3893e (MD5)
Previous issue date: 2005 / Resumo: O objetivo deste trabalho foi avaliar e comparar o desempenho de um material reembasador resiliente à base de resina acrílica (Eversoft com ou sem adição de citrato à composição), submetido ou não ao envelhecimento (termociclagem), sobre as propriedades de deformação permanente e resistência à tração da união com resina acrílica (QC-20®). Para a realização dos ensaios foram confeccionadas 80 amostras, metade para cada ensaio, separadas por composição e submetidas ou não à termociclagem, totalizando 8 grupos. Para o ensaio de tração, foram utilizadas matrizes retangulares de 10mm2 de secção transversal e um espaçador de 3mm de espessura para padronizar o espaço para a base resiliente, cujo molde impresso no silicone polimerizado por reação de condensação foi preenchido com resina acrílica e material resiliente. A resina acrílica foi incluída com o espaçador e após a polimerização, o espaçador foi removido, as amostras de resina acrílica retiradas do molde e realizado o acabamento. As amostras de resina acrílica retornaram ao molde, e no lugar do espaçador, os materiais resilientes foram prensados e termopolimerizados de acordo com as instruções dos fabricantes. Para o ensaio de deformação permanente, foram utilizadas matrizes cilíndricas de 12,7mm de diâmetro e 19mm de altura, cujo molde impresso no silicone foi preenchido com material resiliente. Metade das amostras de cada ensaio foi levada ao termociclador MSCT-3 PLUS, onde foram realizados 3.000 ciclos de 1 minuto de imersão em água a 5±1ºC e 1 minuto a 55±1ºC. A outra metade foi armazenada em água numa estufa a 370C durante 24 horas. As amostras foram submetidas ao ensaio de tração no equipamento EMIC-DL500MF com velocidade de 5 mm/minuto. As amostras foram avaliadas visualmente quanto ao tipo de ruptura ocorrida, e amostras representativas de cada tipo foram analisadas através de microscopia eletrônica de varredura em microscópio modelo JSM 5600 PV (JEOL, Japão). As amostras do estudo de deformação permanente foram ensaiadas em um aparelho mecânico recomendado na especificação no18 da American Dental Association (A.D.A.). Todos os dados obtidos foram submetidos à análise de variância em esquema fatorial 2x2 e as médias comparadas pelo Teste de Tukey, em nível de significância de 5%. Em relação aos valores médios de resistência à tração da união dos materiais não submetidos à termociclagem, o Eversoft com citrato ¿ Experimental apresentou menor valor (0,39 MPa), porém sem diferença estatística com o Eversoft sem citrato ¿ Eversoft® (0,44 MPa). Houve aumento dos valores médios de resistência à tração da união quando submetido à termociclagem para o Eversoft® (0,46 MPa) e Experimental (0,55 MPa), sendo estatisticamente significativo apenas para o material Experimental Em relação aos tipos de fratura, para ambos materiais não submetidos à termociclagem, predominaram rupturas coesivas (80%); e quando submetidos à termociclagem, foram observadas rupturas adesivas para o material Experimental (80%) e adesivas e mistas (40% e 50%, respectivamente) para o Eversoft®. Em relação à deformação permanente, os valores médios obtidos para os materiais Eversoft® e Experimental não submetidos à termociclagem (1,06% e 1,82%, respectivamente) diferiram estatisticamente quando submetidos à termociclagem (1,36% e 1,98 %, respectivamente). A termociclagem não afetou a resistência à tração da união para o material Eversoft®, enquanto o Experimental apresentou elevação no valor médio de resistência à tração da união, com diferença estatística significativa. A termociclagem elevou os valores médios de deformação permanente para ambos materiais. Independentemente do tratamento, o material resiliente Experimental apresentou o valor médio mais elevado para deformação permanente / Abstract: The aim of this study was to evaluate and compare the effect of citrate added or not to a composition of acrylic-based soft liner (Eversoft) on its permanent deformation and bond strength with acrylic resin (QC-20®). Eighty samples were used to carry out the two assays containing 40 specimens each: 2 materials (Eversoft® and Eversoft + citrate) and 2 treatments (with and without thermocycling) totaling 8 groups of 10 specimens each. For the tensile test, rectangular specimens with a 10x10mm2 cross sectional area were prepared for each acrylic resin and soft liner. Acrylic resin specimens were prepared by investing brass dies with a 3mm thick spacer in a denture flask. The dies and spacers were invested in silicone rubber. All dies and the spacer were machined to the same dimensions to standardize acrylic resin and soft liner shape. Specimens were made by processing soft liner against acrylic resin blocks according to the manufacturers¿ directions. For the permanent deformation, the specimens were prepared by investing brass dies (12.7 x 19.0 mm) in a denture flask and the model impressed was filled up with a soft liner. Half of the specimens of each assay were thermocycled using the MSCT-3 Plus with cycles of 1 minute in water at 5±1ºC and 1 minute in water at 55±1ºC, totaling 3000 cycles. The other half was stored in water at 370C for 24h. For the tensile test, the specimens were submitted to a bond strength testing machine (EMIC DL-500 MF) at the crosshead speed of 5mm/minute. Samples were visually evaluated as to the types of rupture observed in this study. The Scanning Electron Microscope JSM 5600 PV (JEOL, Japan) was used to analyze the representative samples. Permanent deformation was measured with an instrument described in the American Dental Association (A.D.A.) - specification number18. The data were submitted to a 2-way analysis of variance and the Tukey test (5%). The bond strength test, without thermocycling, revealed a lower mean value (0.39 MPa) for the group Eversoft with citrate - Experimental; however, no statistically significant difference was observed for the group Eversoft without citrate - Eversoft® (0.44 MPa). Thermocycling did not affect the bond strength regarding Eversoft® (0.46 MPa); however, Experimental presented a higher mean value (0,55 MPa) ¿ statistically significant. Both materials, without thermocycling, presented cohesive failures (80%). When submitted to thermocycling, 80% of adhesive failures were observed for Experimental, and 40% of adhesive and 50% of a combined mode of failures for Eversoft®. In relation to the permanent deformation, Eversoft® and Experimental, not submitted to thermocycling, presented mean values (1.06% and 1.82%, respectively) differing statistically from those submitted to thermocycling (1.36% and 1.98%, respectively). Thermocycling did not affect the bond strength regarding Eversoft®; however, Experimental presented a higher mean value. Thermocycling had a deleterious effect on the permanent deformation of both materials. Regardless of treatment, statistically significant difference was observed for Experimental group, showing the highest permanent deformation permanent value / Mestrado / Protese Dental / Mestre em Clínica Odontológica
|
52 |
Efetividade de duas soluções desinfetantes e da irradiação por micro-ondas na desinfecção de próteses totais contaminadas com staphylococcus aureus resistente à meticilina (MRSA) /Altieri, Karen Tereza. January 2011 (has links)
Orientador: Carlos Eduardo Vergani / Banca: Ana Lucia Machado / Banca: Wander José da Silva / Resumo: Infecções causadas por bactérias resistentes a antibióticos são consideradas causa principal de mortalidade entre indivíduos imunocomprometidos e aproximadamente 50 % destas infecções tem sido relacionadas ao Staphylococcus aureus resistente à meticilina (MRSA). Estes microrganismos, quando presentes no biofilme das próteses dentarias, podem se dispersar nas secreções salivares e se disseminar pelo trato respiratório, causando pneumonia aspirativa. Assim, o presente estudo comparou a efetividade do hipoclorito de sódio a 1 %, digluconato de clorexidina a 2 % e irradiação por micro-ondas na desinfecção de próteses totais e corpos-de-prova circulares de resina acrílica para base de prótese (10 x 2 mm) contaminados com MRSA. Para isso, 36 próteses totais simuladas e 36 corpos-de-prova circulares foram confeccionados, esterilizados, inoculados com MRSA (107 ufc/mL) e incubados a 37 °C (por 24 e 48 h, respectivamente). Após incubação, próteses totais e corpos-de-prova foram distribuídos em 4 grupos de estudo (n=9): GC - não foi realizado nenhum método de desinfecção; GH - foi realizada a imersão em solução de hipoclorito de sódio a 1 % por 10 min; GCl -foi realizada a imersão em solução de digluconato de clorexidina a 2 % por 10 min; GM - foi realizada a desinfecção por irradiação em forno de micro-ondas a 650 W por 3 min. A efetividade dos procedimentos de desinfecção foi avaliada por meio de quantificação de colônias viáveis e da viabilidade celular. Para a quantificação de colônias viáveis, alíquotas de 25 μL da solução resultante das diluições seriadas (10-3 a 10-6 para GC e 100 a 10-3 para os grupos experimentais) foram semeadas em placas de Petri em duplicata e todas as placas foram incubadas por 48 h a 37 °C. As colônias foram quantificadas em ufc/mL. Para verificar a efetividade da desinfecção por micro-ondas em longo prazo... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Infections caused by antibiotic-resistant bacteria have been recognized as a predominant risk factor for mortality in elderly patients and approximately 50 % of these infections have been related to methicillin-resistant Staphylococcus aureus (MRSA). This microorganism, when present in the denture biofilm, can be released into the oral fluids and aspirated into the lower respiratory tract, thus causing infections such as aspiration pneumonia. The present study compared the efficacy of 1 % sodium hypochlorite, 2 % chlorhexidine gluconate, and microwave irradiation in disinfecting simulated complete dentures and circular specimens of acrylic resin denture base material (10 x 2 mm) contaminated with MRSA. Thirty-six dentures and 36 specimens were made, sterilized, inoculated with MRSA (107 cfu/mL), and incubated at 37 °C (for 24 and 48 h, respectively). After incubation, dentures and specimens were divided into 4 groups of study (n=9): PC - positive control, consisting of dentures and specimens not disinfected; HY - soaking in 1 % sodium hypochlorite solution for 10 min; CHL - soaking in 2 % chlorhexidine gluconate solution for 10 min; and MW - irradiating by microwave for 3 min at 650W. The effectiveness of the disinfection procedures was assessed cell viability (quantification of viable cells and XTT reduction method). For quantification procedures, aliquots of suspensions were plated at dilutions (10-3 to 10-6 for PC and 100 to 10-3 for experimental groups) and incubated (37 °C/48 h). Colonies counts (cfu/mL) were quantified. Dentures disinfected were also incubated at 37 °C for 7 days to verify the long-term effectiveness of disinfection. The viability of cells in each group of specimens was evaluated by XTT reduction method. The results showed that all dentures and specimens from the PC groups showed substantial microbial growth. No evidence of microbial growth was observed... (Complete abstract click electronic access below) / Mestre
|
53 |
Efetividade da irradiação por microondas na desinfecção de próteses totais contaminadas por diferentes espécies de Candida isoladas de pacientes HIV positivoSanitá, Paula Volpato [UNESP] 26 March 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:38Z (GMT). No. of bitstreams: 0
Previous issue date: 2007-03-26Bitstream added on 2014-06-13T19:16:49Z : No. of bitstreams: 1
sanita_pv_me_arafo.pdf: 1236296 bytes, checksum: 793fd4710489b2253297ebbc15835736 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A estomatite protética associada à Candida é a forma mais comum de candidíase oral e também uma das infecções oportunistas mais encontradas em pacientes infectados por HIV. Atualmente, a desinfecção de próteses totais através da irradiação por microondas tem sido recomendada para tratamento e prevenção da estomatite protética, tanto em indivíduos saudáveis, quanto em pacientes imunocomprometidos. O presente estudo avaliou a efetividade da irradiação por microondas na desinfecção de próteses totais simuladas contaminadas com 5 diferentes espécies do microorganismo Candida (C. albicans, C. glabrata, C. dubliniensis, C. tropicalis e C. krusei) isoladas de culturas padrão e de pacientes HIV positivo. Para isso, próteses totais simuladas foram confeccionadas, esterilizadas por meio de óxido de etileno e individualmente inoculadas com os microorganismos avaliados. Após o período de incubação (48 horas a 37°C), as próteses foram submetidas à irradiação por microondas a 650W durante 3 minutos. Próteses totais não irradiadas foram utilizadas como controle positivo. A seguir, uma alíquota de 25 æL da solução resultante das diluições seriadas de 10-1 a 10-4 foi semeada em placas de Petri em duplicata e todas as placas foram incubadas por 48 horas a 37°C. As colônias foram quantificadas em ufc/mL. Para verificar a efetividade da desinfecção por microondas a longo prazo, as próteses totais irradiadas foram incubadas a 37°C por 7 dias. Os resultados obtidos foram analisados estatisticamente pelos testes de ANOVA e de Tukey (a=0.05). As próteses totais contaminadas com todas as espécies de Candida avaliadas demonstraram esterilização após irradiação por microondas durante 3 minutos a 650W. Todas as próteses do grupo controle positivo demonstraram crescimento microbiológico após incubação nas placas de Petri. / The most common form of oral candidiasis is Candida-associated denture stomatitis. Oral candidiasis is also a frequent manifestation of HIV infection. Microwave disinfection of complete dentures has been recommended to treat and prevent denture stomatitis in non-immune compromised patients. The present study evaluated the effectiveness of microwave irradiation on the disinfection of simulated complete dentures inoculated with ATCC and HIV isolates of 5 species of Candida (C. albicans, C. glabrata, C. dubliniensis, C. tropicalis and C. krusei). Simulated complete dentures were made, sterilized and individually inoculated with the tested microorganisms. After incubation for 48 hours at 37°C, dentures were submitted to microwave irradiation (650W for 3 minutes). Non-irradiated dentures were used as positive controls. Replicate aliquots of suspensions were plated at dilutions 10-1-10-4 and incubated for 48 hours at 37°C. Colonies counts (cfu/mL) of each plate were quantified. To verify the long-term effectiveness of microwave disinfection, dentures were incubated at 37°C for 7 days. Data were analyzed with two-way ANOVA and Tukey HSD tests (a=0.05). The results indicated that complete dentures contaminated with all Candida yeasts showed sterilization after microwave irradiation for 3 minutes at 650W. All control dentures showed microbial growth on the plates. The cfu/mL for C. glabrata was significantly higher than those of C. albicans, C. dubliniensis and C. tropicalis whereas the cfu/mL for C. krusei was significantly lower. The cfu/mL for clinical isolates was significantly higher than those of ATCC yeasts. Microwave irradiation for 3 minutes at 650W resulted in sterilization of complete dentures contaminated with the 5 species of Candida isolated from HIV-infected patients.
|
54 |
Efetividade de duas soluções desinfetantes e da irradiação por micro-ondas na desinfecção de próteses totais contaminadas com staphylococcus aureus resistente à meticilina (MRSA)Altieri, Karen Tereza [UNESP] 28 March 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:38Z (GMT). No. of bitstreams: 0
Previous issue date: 2011-03-28Bitstream added on 2014-06-13T20:18:32Z : No. of bitstreams: 1
altieri_kt_me_arafo.pdf: 598917 bytes, checksum: 3b01564a77c1be4471454056881b7028 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Infecções causadas por bactérias resistentes a antibióticos são consideradas causa principal de mortalidade entre indivíduos imunocomprometidos e aproximadamente 50 % destas infecções tem sido relacionadas ao Staphylococcus aureus resistente à meticilina (MRSA). Estes microrganismos, quando presentes no biofilme das próteses dentarias, podem se dispersar nas secreções salivares e se disseminar pelo trato respiratório, causando pneumonia aspirativa. Assim, o presente estudo comparou a efetividade do hipoclorito de sódio a 1 %, digluconato de clorexidina a 2 % e irradiação por micro-ondas na desinfecção de próteses totais e corpos-de-prova circulares de resina acrílica para base de prótese (10 x 2 mm) contaminados com MRSA. Para isso, 36 próteses totais simuladas e 36 corpos-de-prova circulares foram confeccionados, esterilizados, inoculados com MRSA (107 ufc/mL) e incubados a 37 °C (por 24 e 48 h, respectivamente). Após incubação, próteses totais e corpos-de-prova foram distribuídos em 4 grupos de estudo (n=9): GC - não foi realizado nenhum método de desinfecção; GH - foi realizada a imersão em solução de hipoclorito de sódio a 1 % por 10 min; GCl -foi realizada a imersão em solução de digluconato de clorexidina a 2 % por 10 min; GM - foi realizada a desinfecção por irradiação em forno de micro-ondas a 650 W por 3 min. A efetividade dos procedimentos de desinfecção foi avaliada por meio de quantificação de colônias viáveis e da viabilidade celular. Para a quantificação de colônias viáveis, alíquotas de 25 μL da solução resultante das diluições seriadas (10-3 a 10-6 para GC e 100 a 10-3 para os grupos experimentais) foram semeadas em placas de Petri em duplicata e todas as placas foram incubadas por 48 h a 37 °C. As colônias foram quantificadas em ufc/mL. Para verificar a efetividade da desinfecção por micro-ondas em longo prazo... / Infections caused by antibiotic-resistant bacteria have been recognized as a predominant risk factor for mortality in elderly patients and approximately 50 % of these infections have been related to methicillin-resistant Staphylococcus aureus (MRSA). This microorganism, when present in the denture biofilm, can be released into the oral fluids and aspirated into the lower respiratory tract, thus causing infections such as aspiration pneumonia. The present study compared the efficacy of 1 % sodium hypochlorite, 2 % chlorhexidine gluconate, and microwave irradiation in disinfecting simulated complete dentures and circular specimens of acrylic resin denture base material (10 x 2 mm) contaminated with MRSA. Thirty-six dentures and 36 specimens were made, sterilized, inoculated with MRSA (107 cfu/mL), and incubated at 37 °C (for 24 and 48 h, respectively). After incubation, dentures and specimens were divided into 4 groups of study (n=9): PC - positive control, consisting of dentures and specimens not disinfected; HY - soaking in 1 % sodium hypochlorite solution for 10 min; CHL - soaking in 2 % chlorhexidine gluconate solution for 10 min; and MW - irradiating by microwave for 3 min at 650W. The effectiveness of the disinfection procedures was assessed cell viability (quantification of viable cells and XTT reduction method). For quantification procedures, aliquots of suspensions were plated at dilutions (10-3 to 10-6 for PC and 100 to 10-3 for experimental groups) and incubated (37 °C/48 h). Colonies counts (cfu/mL) were quantified. Dentures disinfected were also incubated at 37 °C for 7 days to verify the long-term effectiveness of disinfection. The viability of cells in each group of specimens was evaluated by XTT reduction method. The results showed that all dentures and specimens from the PC groups showed substantial microbial growth. No evidence of microbial growth was observed... (Complete abstract click electronic access below)
|
55 |
Análise por computação gráfica da variação da posição relativa dos dentes artificiais antes e após o processamento de próteses totais superioresShibayama, Ricardo [UNESP] 19 September 2002 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0
Previous issue date: 2002-09-19Bitstream added on 2014-06-13T19:37:38Z : No. of bitstreams: 1
shibayama_r_me_araca.pdf: 3106543 bytes, checksum: c84fd00a6f34341aaf54e2572db11b66 (MD5) / Investigamos a alteração da posição dos dentes artificiais durante o processamento de próteses totais, utilizando as resinas de marcas comerciais QC 20 (Dentsply) e Onda Cryl (Clássico - específico de microondas), com inclusão em gesso e com muralha de silicone, polimerizadas tanto pelo método de banho por água quente, quanto pela polimerização por energia de microondas. Foram utilizadas 40 amostras, divididas em 4 grupos de 10, que receberam os seguintes tipos de processamento. a) grupo 1: incluídos em muflas metálicas com muralha de gesso pedra e polimerização convencional. b) grupo 2: incluídos em muflas de fibra de vidro com muralha de gesso pedra e polimerização com microondas. c) grupo 3: incluídos em muflas metálicas com muralha de silicone e polimerização convencional. d) grupo 4: incluídos em muflas de fibra de vidro com muralha de silicone e polimerização por energia de microondas. Para detecção dos deslocamentos dentais utilizamos um guia de resina acrílica com 5 pontos pré-determinados que proporcionou pontos de referência nas réplicas que permitiram mensurar tais deslocamentos através da utilização do programa de computador AutoCad. Com os resultados obtidos podemos concluir que: a) todas as amostras sofreram alteração da posição dos dentes após o processamento, b) a técnica com a menor movimentação dos dentes artificiais foi a técnica 4. / This study investigated artificial tooth movement during the procedures of complete dentures base, using two different types of resins: QC 20 (Dentsply) and OndaCryl (Clássico specify for microwave energy), with gypsum stone mould and silicone mould. We used thermopolymerization in water bath and microwave polymerization. The forty samples utilized were divided into four groups of ten, which received the following type of inclusion and processing. Group 1: included in metallic flasks with gypsum stone mould and thermopolymerization in water bath and microwave polymerization; Group 2: included in resin-fiber glass flasks with gypsum stone mold and microwave polymerization; Group 3: included in metallic flasks with silicone mold and thermopolymerization in water bath; Group 4: included in resin-fiber glass flasks with silicone mould and microwave polymerization. For the measurement of artificial tooth movement, we used a resin acrylic guide with five daily determined points which provide references points. The AutoCad R 14 computer program was utilized for the measurements. All data were submitted to ANOVA and Tukey test. With the results we can conclude that: a) all the samples suffer artificial tooth movement, b) the smaller artificial tooth movement happen in group four.
|
56 |
Validação do teste de habilidade de mistura com goma de mascar de duas cores para avaliação da performance mastigatória em usuários de próteses totais / Validation of mixing ability test with two-colour chewing gum to assess masticatory performance in complete denture wearersSilva, Lorrany Cândido da 20 March 2017 (has links)
Submitted by Luciana Ferreira (lucgeral@gmail.com) on 2017-04-20T13:48:46Z
No. of bitstreams: 2
Dissertação - Lorrany Cândido da Silva - 2017.pdf: 1733793 bytes, checksum: f8ab882fc9e50895326cd60c7ed5c27d (MD5)
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2017-04-20T13:49:13Z (GMT) No. of bitstreams: 2
Dissertação - Lorrany Cândido da Silva - 2017.pdf: 1733793 bytes, checksum: f8ab882fc9e50895326cd60c7ed5c27d (MD5)
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2017-04-20T13:49:13Z (GMT). No. of bitstreams: 2
Dissertação - Lorrany Cândido da Silva - 2017.pdf: 1733793 bytes, checksum: f8ab882fc9e50895326cd60c7ed5c27d (MD5)
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Previous issue date: 2017-03-20 / Fundação de Amparo à Pesquisa do Estado de Goiás - FAPEG / Objective: To test the validity and reliability of a method to measure the masticatory performance of complete denture wearers employing a two-colour gum mixing ability test through visual and opto-electronical analysis. Material and Methods: A sample of 75 subjects was selected from patients who received new conventional tissue-supported complete dentures in a clinic at the Federal University of Goiás. Masticatory tests were performed using a two-colour chewing gum that was masticated for 5, 10, 20, 30 and 50 chewing cycles, performed in a random order. The mixing level of the two colours of the chewed gum was assessed visually by two independent raters based on a 5-point ordinal scale. Then, the specimens were flattened into a 1 mm width wafer, scanned and saved as a two-sided digital image. Each pair of images was submitted to a colourimetric analysis using a custom-made software (ViewGum©, Dhal Software, Greece). The circular variance of hue (VOH) was used as a measure of the level of the colour mixture. The lower is the VOH, the greater is the mixture and, consequently, the masticatory performance. In the current study design, a varying number of chewing cycles simulated different levels of masticatory performance in one subject. The intra and inter-examiner agreement for the visual analysis was measured by the intraclass correlation coefficient and the weighted Kappa. The reliability of VOH analysis was assessed using the Bland-Altman plots. Results: Overall inter and intra-rater agreement in visual analysis was 64% and 68%, respectively (almost 99% of scores ranged within ±1 point). Overall weighted kappa was >0.80 and intraclass correlation coefficient was 0.91. A proportional increase in the level of mixture occurred with increased number of chewing cycles for both the visual and colourimetric analysis (p<0.001). Similarly, VOH and the visual
12
analysis were highly correlated (r= -0.89; p<0.001). Bland-Altman plots revealed excellent agreement and extremely low systematic error between duplicated VOH measures. Conclusion: The two-colour chewing gum test is a valid and reliable method for assessment of the masticatory performance in complete denture wearers using both the visual and electronic colourimetric analysis. / Resumo: Objetivo: Testar a validade e a confiabilidade de um método para
mensurar a performance mastigatória de usuários de próteses totais
convencionais, empregando um teste de habilidade de mistura de goma de mascar
de duas cores por meio de análise visual e opto-eletrônica. Material e Métodos:
Uma amostra de 75 participantes foi selecionada entre os pacientes que
receberam próteses totais convencionais em uma clínica da Universidade Federal
de Goiás. Os testes mastigatórios foram realizados, em ordem aleatória, usando
uma goma de mascar de duas cores que foi mastigada por 5, 10, 20, 30 e 50
ciclos mastigatórios. O nível de mistura das duas cores da goma mastigada foi
avaliada visualmente por dois avaliadores independentes, com base em uma
escala ordinal de 5 categorias. Em seguida, os espécimes foram achatados em
uma lâmina de 1 mm de espessura, escaneados em ambos os lados e salvos como
imagem digital. Cada par de imagens foi submetida à uma análise colorimétrica
usando um software customizado (ViewGum©, Dhal Software, Greece). A
variância circular da matiz (VCM) foi usada como a medida do nível de mistura das
cores. Quanto menor foi o VCM, maior foi a mistura e, consequentemente, melhor
a performance mastigatória. No desenho deste estudo, um número variável de
ciclos mastigatórios simulou diferentes níveis de performance mastigatória em um
indivíduo. A concordância intra e inter-examinador para a análise visual foi
mensurada por meio do coeficiente de correlação intraclasse e do Kappa
ponderado. A confiabilidade da análise VCM foi avaliada por meio do gráfico Bland-
Altman. Resultados: A concordância geral inter e intra-examinador na análise
visual foi 64% e 68%, respectivamente (quase 99% dos escores variaram dentro
de ±1). O Kappa ponderado geral foi >0,80 e o coeficiente de correlação
intraclasse foi de 0,91. Um aumento proporcional do nível de mistura ocorreu com
o aumento do número de ciclos mastigatórios, tanto pela análise visual quanto
pela análise colorimétrica (p<0,001). Da mesma forma, os valores de VCM e a
análise visual foram altamente correlacionados (r= -0.89; p<0,001). O gráfico
Bland-Altman revelou concordância excelente e erro sistemático extremamente baixo entre as mensurações VCM duplicadas. Conclusão: O teste com a goma de mascar de duas cores é um método válido e confiável para avaliação da performance mastigatória em usuários de próteses totais convencionais usando tanto a análise visual quanto a análise colorimétrica.
|
57 |
Combination of Digital and Conventional Workflows in the CAD/CAM-Fabrication of an Implant-Supported OverdentureSchmidt, Michael Benno, Rauch, Angelika, Schwarzer, Marcus, Lethaus, Bernd, Hahnel, Sebastian 20 April 2023 (has links)
Completely digital workflows for the fabrication of implant-supported removable restorations are not yet common in clinical dental practice. The aim of the current case report is to illustrate a reliable and comfortable workflow that reasonably merges conventional and digital workflows for the CAD/CAM-fabrication of implant-supported overdentures. The 53-year old patient was supplied with a digitally processed complete denture in the upper jaw and, simultaneously, with an overdenture supported by four interforaminal implants in the lower jaw. The overdenture included a completely digitally processed and manufactured alloy framework that had been fabricated by selective laser sintering. The case report indicates that digital manufacturing processes for extensive and complex removable restorations are possible. However, as it is currently not yet possible to digitally obtain functional impressions, future developments and innovations might focus on that issue.
|
58 |
Avaliação de overdentures mandibulares com diferentes sistemas de retenção: análise fotoelástica da transmissão de tensões e efeito de carga cíclica na força de retenção / Evaluation of mandibular overdentures with different attachments systems: Photoelastic stress analysis and effect of cyclic loading on retention forceAguiar Junior, Fábio Afrânio de 01 July 2013 (has links)
O surgimento dos implantes osseointegrados melhorou a qualidade de vida de pacientes edêntulos. Seu uso favorece retenção e estabilidade, gerando maior eficiência mastigatória e conforto. O objetivo deste estudo foi avaliar manutenção da força de retenção e padrões de tensões gerados na mandíbula em overdentures confeccionadas com dois sistemas de retenção retidas por 2 ou 3 implantes. Teste de carga cíclica e análise fotoelástica de tensões foram realizados. Para o teste de carga cíclica foram utilizados modelos representativos de mandíbulas desdentadas e os grupos analisados foram: A) 2 implantes com barra clipe; B) 3 implantes com barra clipe; C) 2 implantes com barra clipe e bola/o\'ring nas extremidades; D) 3 implantes com barra clipe e bola/o\'ring nas extremidades. Cinco espécimes por grupo foram submetidos à ciclagem e 5 permaneceram imersos na máquina de ciclagem (controle). As leituras de força de retenção foram realizadas por ensaio de tração em máquina de ensaios universal antes da ciclagem e a cada 500 mil ciclos. A ciclagem foi realizada com frequência de 1,8 Hz, carga de 130 N, por 2 milhões de ciclos. Para a aplicação de carga, foram feitas pontas correspondentes à arcada antagonista unilateral posterior. Os dados obtidos foram analisados estatisticamente pelo modelo linear de efeitos mistos. Para a análise fotoelástica, foi feito um modelo mestre curvo em resina acrílica. O modelo foi preparado para conter cinco implantes, paralelos, distribuídos na região interforaminal. Grupo com 4 implantes com barra clipe e o\'rings nas extremidades foi incluído como controle. Prótese total foi confeccionada e usada em todos os grupos. A cada grupo, nova captura de retentores foi realizada. Para obtenção dos modelos fotoelásticos, foram confeccionados moldes em silicone do modelo mestre. A verificação das tensões em torno dos implantes foi realizada por meio de análise fotoelástica qualitativa de transmissão sob aplicação de carga cêntrica estática de 50 N. Diferentes tipos de pontas e locais de aplicação de carga foram usados. Os resultados demonstraram que carga cíclica influencia na perda de retenção overdentures mandibulares. Comparando grupos controle e teste, observou-se que os grupos com três implantes apresentaram maior influência da ciclagem na perda de retenção. Os sistemas de retenção estudados apresentaram comportamentos diferentes até um milhão de ciclos, após não houve diferença quanto à manutenção de retenção. Todos os grupos mantiveram retenção satisfatória ao final da ciclagem. Três implantes apresentaram maior tensão ao redor dos implantes e pouca ou nenhuma sobre o rebordo. Nos grupos com dois implantes, aplicação de carga posterior gerou tensões no rebordo alveolar e implantes. Grupos com extensões distais evidenciaram uma maior tensão ao redor dos implantes que os sem extensão. / The appearance of osseointegrated dental implants improved the quality of life of fully edentulous patients. Implants promote retention and stability, producing higher masticatory efficiency and comfort. The aim of this study was analyze the retention maintenance and the stress pattern generated by two or three implants-supported mandibular overdentures with two attachments systems. Cyclic loading test and photoelastic stress analysis were performed. For the cyclic loading test, edentulous mandibular models were used. The analyzed groups were: A) 2 implants with bar clip; B) 3 implants with bar clip; C) 2 implants with bar clip and balls/o\'rings in the extremity; D) 3 implants with bar clip and balls/o\'rings in the extremity. Five specimens per group were submitted to cyclic loading and five were kept immersed inside the test machine (control group). The measurements of retention force were performed by tensile test in a universal testing machine before cyclic loading and after each 500 thousands cycles. The cycling was performed with frequency of 1.8 Hz, loading of 130 N, up to two million cycles. For the load application, tips corresponding to posterior unilateral antagonist teeth were produced. Data were statistically analyzed by linear mixed-effects model. For the photoelastic analysis, a curved master model was produced in acrylic resin. The model contained five parallel implants, distributed in interforaminal area. A group with 4 implants splinted with bar clip and balls/o\'rings in the extremity was included as a control. Complete denture was made and used in all groups. In each group, incorporating of new attachments was performed. For the obtainment of photoelastic models, silicone impression of the master model was performed. The assessment of stress around implants was done through quantitative transmission photoelastic analysis under static centric load application of 50 N. Different sorts of tips and load application places were used. The results showed that cyclic load influences the retention loss of mandibular overdentures. Comparing test and control groups, it was observed that groups with three implants showed higher influence of cyclic loading in retention loss. The studied attachments systems showed different behaviors up to one million cycles, after that there was not difference in the maintenance of retention. All groups had satisfactory retention at the end of cycling. Groups with three implants showed higher stress around implants and lower or none on alveolar ridge. In groups with two implants, load application on posterior area caused stress on alveolar ridge and implants. Groups with distal extensions demonstrated higher stress around implants than groups without extension.
|
59 |
Efetividade da irradiação por microondas na desinfecção de próteses totais contaminadas por diferentes espécies de Candida isoladas de pacientes HIV positivo /Sanitá, Paula Volpato. January 2007 (has links)
Orientador: Carlos Eduardo Vergani / Banca: Ana Cláudia Pavarina / Banca: Raphael Freitas de Souza / Resumo: A estomatite protética associada à Candida é a forma mais comum de candidíase oral e também uma das infecções oportunistas mais encontradas em pacientes infectados por HIV. Atualmente, a desinfecção de próteses totais através da irradiação por microondas tem sido recomendada para tratamento e prevenção da estomatite protética, tanto em indivíduos saudáveis, quanto em pacientes imunocomprometidos. O presente estudo avaliou a efetividade da irradiação por microondas na desinfecção de próteses totais simuladas contaminadas com 5 diferentes espécies do microorganismo Candida (C. albicans, C. glabrata, C. dubliniensis, C. tropicalis e C. krusei) isoladas de culturas padrão e de pacientes HIV positivo. Para isso, próteses totais simuladas foram confeccionadas, esterilizadas por meio de óxido de etileno e individualmente inoculadas com os microorganismos avaliados. Após o período de incubação (48 horas a 37°C), as próteses foram submetidas à irradiação por microondas a 650W durante 3 minutos. Próteses totais não irradiadas foram utilizadas como controle positivo. A seguir, uma alíquota de 25 æL da solução resultante das diluições seriadas de 10-1 a 10-4 foi semeada em placas de Petri em duplicata e todas as placas foram incubadas por 48 horas a 37°C. As colônias foram quantificadas em ufc/mL. Para verificar a efetividade da desinfecção por microondas a longo prazo, as próteses totais irradiadas foram incubadas a 37°C por 7 dias. Os resultados obtidos foram analisados estatisticamente pelos testes de ANOVA e de Tukey (a=0.05). As próteses totais contaminadas com todas as espécies de Candida avaliadas demonstraram esterilização após irradiação por microondas durante 3 minutos a 650W. Todas as próteses do grupo controle positivo demonstraram crescimento microbiológico após incubação nas placas de Petri. / Abstract: The most common form of oral candidiasis is Candida-associated denture stomatitis. Oral candidiasis is also a frequent manifestation of HIV infection. Microwave disinfection of complete dentures has been recommended to treat and prevent denture stomatitis in non-immune compromised patients. The present study evaluated the effectiveness of microwave irradiation on the disinfection of simulated complete dentures inoculated with ATCC and HIV isolates of 5 species of Candida (C. albicans, C. glabrata, C. dubliniensis, C. tropicalis and C. krusei). Simulated complete dentures were made, sterilized and individually inoculated with the tested microorganisms. After incubation for 48 hours at 37°C, dentures were submitted to microwave irradiation (650W for 3 minutes). Non-irradiated dentures were used as positive controls. Replicate aliquots of suspensions were plated at dilutions 10-1-10-4 and incubated for 48 hours at 37°C. Colonies counts (cfu/mL) of each plate were quantified. To verify the long-term effectiveness of microwave disinfection, dentures were incubated at 37°C for 7 days. Data were analyzed with two-way ANOVA and Tukey HSD tests (a=0.05). The results indicated that complete dentures contaminated with all Candida yeasts showed sterilization after microwave irradiation for 3 minutes at 650W. All control dentures showed microbial growth on the plates. The cfu/mL for C. glabrata was significantly higher than those of C. albicans, C. dubliniensis and C. tropicalis whereas the cfu/mL for C. krusei was significantly lower. The cfu/mL for clinical isolates was significantly higher than those of ATCC yeasts. Microwave irradiation for 3 minutes at 650W resulted in sterilization of complete dentures contaminated with the 5 species of Candida isolated from HIV-infected patients. / Mestre
|
60 |
Influência do processamento de próteses totais maxilares com diferentes espessuras da base: análise gráfica da movimentação dos dentes artificiaisMazaro, José Vitor Quinelli [UNESP] 15 December 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:57Z (GMT). No. of bitstreams: 0
Previous issue date: 2005-12-15Bitstream added on 2014-06-13T20:18:38Z : No. of bitstreams: 1
mazaro_jvq_me_araca.pdf: 2035782 bytes, checksum: e67d1a0017e9c678266d158062acc962 (MD5) / Universidade Estadual Paulista (UNESP) / A relação existente entre os métodos de processamento das resinas acrílicas e a espessura de resina das bases de dentaduras, bem como a associação com o tamanho e forma do arco maxilar, tem sido um assunto bastante discutido no que diz respeito à possíveis alterações no posicionamento dos dentes e selamento posterior de próteses totais maxilares. Sendo assim, o propósito desse trabalho foi avaliar a movimentação dentária que ocorre durante o processamento de próteses totais maxilares com três diferentes espessuras de base, frente a dois métodos de inclusão e submetidas à polimerização por microondas. Quarenta e duas (42) amostras foram aleatoriamente divididas em 6 grupos de 7 amostras cada, respeitando, evidentemente, a espessura da base (1,25 mm - 2,50 mm - 3,75 mm) e o tipo de revestimento em mufla (silicone e gesso pedra). Pontos foram demarcados sobre os dentes artificiais para permitir a mensuração das R ee ssum o amostras através do software AutoCad. A diferença das médias dos segmentos entre o modelo encerado e demuflado de cada grupo foi submetida à analise de variância (ANOVA) e teste de Tukey. De acordo com os resultados obtidos pode-se concluir que: todas as técnicas de processamento juntamente com as diferentes espessuras de base de prótese total avaliadas apresentaram alteração na posição dos dentes artificiais após o processamento. A técnica de inclusão com barreira de silicone foi a que apresentou as maiores alterações dimensionais, independentemente da espessura. Na análise dos segmentos, houve uma maior alteração dos segmentos A/B/C (Triângulo maior) com relação aos segmentos D/E/F (Triângulo menor). Independente do tipo de inclusão, não houve diferença estatística entre as espessuras das bases (p<0,059), entretanto, analisando o comportamento de alteração, as prótese totais com bases mais finas apresentaram maior... . / The existent relationship between the methods of processing of the acrylic resins and the thickness of dentures bases resin, as well as the association with the size and form of the maxillary arch, it has been a subject quite discussed with regard to possible alterations in the teeth positioning and maxillary complete denture postdamming. So that, the aim of the study was to evaluate the dental movement that it happens during the processing of maxillary complete dentures with three base thickness different, front of two inclusion methods and submitted to the microwaves polymerization. Forty two (42) samples were randomly divided in 6 groups of 7 samples each, respecting, evidently, the base thickness (1,25 mm - 2,50 mm - 3,75 mm) and the type in flask investment (silicone and plaster stone). Points were demarcated on the artificial teeth to allow the measurement of the samples through the AutoCad software. The averages difference of the segments between the Ab ss tt rr a cc tt waxed model and deflasked of each group was submitted to it analysis of variance (ANOVA á=0,05) and Tukey test. In agreement with the obtained results it can be conclusion that: all the processing techniques together with the different thickness of complete denture base evaluated, presented alteration in the artificial teeth positionig after the processing. The silicone flasking technique was that presented the largest dimensional alterations, independently of the thickness. In the segments analysis, there was a larger alteration of the segments A/B/C (larger Triangle) regarding the segments D/E/F (smaller Triangle). Independent of the flasking type, there was not difference statistics among the thickness of the bases (p <0,059), however, analyzing the alteration behavior, thinner bases presented larger movement in the position of the artificial teeth than thicken base that complete denture them. The completed... (Complete abstract, click electronic address below).
|
Page generated in 0.0725 seconds