• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 181
  • 176
  • 105
  • 43
  • 20
  • 15
  • 12
  • 7
  • 6
  • 3
  • 3
  • 3
  • 3
  • 1
  • 1
  • Tagged with
  • 668
  • 94
  • 84
  • 75
  • 70
  • 60
  • 59
  • 58
  • 55
  • 53
  • 49
  • 46
  • 41
  • 40
  • 38
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

Autour des fluorures et oxydes de zinc : propriétés opto-électroniques et magnéto-électroniques / Investigation of zinc oxides and fluorides : opto-electronic and magnetic properties

Serier, Hélène Martine 02 October 2009 (has links)
Ce travail porte sur l'étude des propriétés opto- et magnéto-électroniques des oxydes et fluorures de zinc. Dans une première partie, nous avons étudié les propriétés d'absorption/réflexion dans le proche-IR de poudres d'oxyde de zinc dopées de manière aliovalente par l'aluminium ou le gallium. Une grande partie du travail a consisté en la détermination précise du taux de dopant introduit pour les différentes conditions expérimentale utilisées. Les taux de dopant déterminés ont ensuite été corrélés aux propriétés optiques mesurées par spectrométrie de réflexion diffuse. Nous avons voulu réaliser le même travail sur le fluorure de zinc mais nous avons été confrontés à la difficulté de doper ce composé par l'aluminium à cause de la grande stabilité chimique du fluorure AlF3. En revance, une étude structurale approfondie a été réalisée sur un hydroxyfluorure de zinc ZnOHF, précurseur pouvant être dopé de manières aliovalente. Dans la dernière du manuscrit, nous avons utilisé nos compétences relatives au suivi du dopage pour étudier l'effet des porteurs libres sur les propriétés magnétiques des oxydes de zinc dopés au cobalt. D'un point de vue expérimental, aucun effet des porteurs n'a été recensé, seul un comportement paramagnétique ayant été observé. / This work deals with the opto-electronic and magnetic properties of zinc oxides and fluorides. In a first part, NIR absorption / reflection properties of aluminium and gallium doped zinc oxides powders have been studied. Dopant rates have been accurately determined for different experimental conditions and correlated with optical properties which were measured by diffuse reflection spectrometry. The same investigation has been performed on zinc fluoride but this compound could not have been doped by aluminium because of high chemical stability of aluminium fluoride. However, a structural study has been carried out on zinc hydroxyfluoride, which can be doped by aluminium. The last part of this dissertation deals with the investigation of carriers effect, which can be followed by diffuse reflection, on magnetic properties of cobalt doped zinc oxide. Free carriers have beeb no effect, only a paramagnetic behaviour has been observed.
112

IL10 und CpG induzieren über STAT3 und NF-κB die Zellproliferation und die Genexpression des Glutaminolyseenzyms GOT2 in der Modellzelllinie P493-6 / IL10 and CpG induce cell proliferation and gene expression of the glutaminolysis enzyme GOT2 in the model cell line P493-6 via STAT3 and NF-κB

Kemper, Judith 09 May 2019 (has links)
No description available.
113

Système d'imagerie pour la caractérisation en couches de la peau par réflectance diffuse / Imaging system for the characterization of skin layers using diffuse reflectance

Petitdidier, Nils 27 November 2018 (has links)
Les travaux effectués au cours de cette thèse concernent le développement d’un instrument à faible coût et porté sur la personne permettant le suivi quantitatif des paramètres physiologiques de la peau in vivo et de manière non invasive. L’instrument est fondé sur la technique de Spectroscopie de Réflectance Diffuse résolue spatialement (srDRS). Cette technique fournit une quantification absolue des propriétés optiques endogènes d’absorption et de diffusion du tissu sondé et possède un potentiel pour la caractérisation de ces propriétés en couches de la peau.Afin de maximiser ce potentiel, notre approche repose sur l’utilisation d’un capteur matriciel placé en contact avec le tissu et permettant l’imagerie de réflectance diffuse à haute résolution spatiale. Les travaux présentés ici comprennent la spécification et la validation d’une architecture innovante permettant la mise en œuvre de l’approche proposée, l’implémentation d’un système porté sur la personne et bas coût basé sur cette architecture et l’évaluation des performances de ce système au travers d’expérimentations à la fois sur fantômes de peau et in vivo. Les résultats obtenus valident le potentiel de l’instrument développé pour le suivi quantitatif et non-invasif des propriétés de la peau. L’approche proposée est prometteuse pour l’analyse de milieux en couches tels que la peau et ouvre la voie au développement d’une nouvelle génération d’instruments portés sur la personne et bas coûts pour le suivi en continu des propriétés optiques des tissus. / This work presents the development of a low-cost, wearable instrument for quantitative monitoring of skin physiological parameters toward non-invasive diagnostics in vivo. The instrument is based on the spatially resolved Diffuse Reflectance Spectroscopy (srDRS) technique, which provides absolute quantification of absorption and scattering endogenous properties of the probed tissue volume with a potential to discriminate between properties of individual skin layers. In the developed instrument, this potential is maximized by the use of a multi-pixel image sensor to perform contact, high resolution imaging of the diffuse reflectance. This study comprises the specification and validation of a novel srDRS system architecture based on the proposed approach, the implementation of this architecture into a low-cost, wearable device and the evaluation of the device performance both on tissue-simulating phantoms and in vivo. Results validate the potential of the instrument for the non-invasive, quantitative monitoring of tissue properties. The described approach is promising for addressing the analysis of layered tissue suchas skin and paves the way for the development of low-cost, wearable devices for continuous, passive monitoring of tissue optical properties.
114

Search for dark matter in the Milky Way halo with the High Energy Stereoscopic System

Spengler, Gerrit Christian 06 February 2014 (has links)
In dieser Arbeit wird mit Hilfe von Daten, die mit dem High Energy Stereocopic System (H.E.S.S.) in Namibia aufgenommen wurden, indirekt nach dunkler Materie im Halo der Milchstraße gesucht / An indirect search for the presence of dark matter particles in the halo of the Milky Way with data that were recorded with the High Energy Stereoscopic System (H.E.S.S.) is discussed in this work
115

Optimisation de la tête d'extrusion pour la fabrication de pièces thermoplastiques / Optimization of the extrusion die for the manufacture of thermoplastic parts

Lebaal, Nadhir 15 June 2007 (has links)
L’objectif de nos travaux de recherches est d’homogénéiser la répartition des vitesses à la sortie des filières, par la maîtrise et l’optimisation des paramètres géométrique et opératoires. Une procédure d’optimisation, basée sur la méthode de surface de réponse, a été proposée. Toutes les fonctions sont écrites sous une forme explicite en utilisant soit l’approximation diffuse ou l’interpolation Krigeage. Compte tenu de la présence des contraintes non linéaires, un algorithme de type SQP, a été utilisé. Pour localiser l’optimum global avec précision, une procédure d’échantillonnage auto adaptatif de l’espace de recherche a été adoptée. Les résultats d’optimisation mettent en évidence l'intérêt de l’optimisation des paramètres géométriques et opératoires du procédé d’extrusion. Une filière optimisée numériquement pour une gamme différente de polymère a été réalisée et une comparaison expérimentale a permis de valider toute la procédure de simulation et d’optimisation mise en place. / The objective of our research tasks is to homogeneous the velocity distribution on the outlet side of the die, through the control and the optimization of the geometrical parameters and operating conditions. An optimization procedure, based on the response surface method, was proposed. All the functions are written in an explicit form by using the either diffuse approximation or the Kriging interpolation. Due to the presence of the nonlinear constraints, an iterative algorithm of type SQP, was used. To find the global optimum with precision and at lower cost an auto-adaptive research space is adopted. The results of three other applications highlight the interest of the optimization of the geometrical and operational parameters of the extrusion process. A die optimized numerically for multiple operating conditions and materials was produced. An experimental comparison allowed us to validate all the procedure of simulation and optimization put in place.
116

MULTIMODAL NONCONTACT DIFFUSE OPTICAL REFLECTANCE IMAGING OF BLOOD FLOW AND FLUORESCENCE CONTRASTS

Irwin, Daniel 01 January 2018 (has links)
In this study we design a succession of three increasingly adept diffuse optical devices towards the simultaneous 3D imaging of blood flow and fluorescence contrasts in relatively deep tissues. These metrics together can provide future insights into the relationship between blood flow distributions and fluorescent or fluorescently tagged agents. A noncontact diffuse correlation tomography (ncDCT) device was firstly developed to recover flow by mechanically scanning a lens-based apparatus across the sample. The novel flow reconstruction technique and measuring boundary curvature were advanced in tandem. The establishment of CCD camera detection with a high sampling density and flow recovery by speckle contrast followed with the next instrument, termed speckle contrast diffuse correlation tomography (scDCT). In scDCT, an optical switch sequenced coherent near-infrared light into contact-based source fibers around the sample surface. A fully noncontact reflectance mode device finalized improvements by combining noncontact scDCT (nc_scDCT) and diffuse fluorescence tomography (DFT) techniques. In the combined device, a galvo-mirror directed polarized light to the sample surface. Filters and a cross polarizer in stackable tubes promoted extracting flow indices, absorption coefficients, and fluorescence concentrations (indocyanine green, ICG). The scDCT instrumentation was validated through detection of a cubical solid tissue-like phantom heterogeneity beneath a liquid phantom (background) surface where recovery of its center and dimensions agreed with the known values. The combined nc_scDCT/DFT identified both a cubical solid phantom and a tube of stepwise varying ICG concentration (absorption and fluorescence contrast). The tube imaged by nc_scDCT/DFT exhibited expected trends in absorption and fluorescence. The tube shape, orientation, and localization were recovered in general agreement with actuality. The flow heterogeneity localization was successfully extracted and its average relative flow values in agreement with previous studies. Increasing ICG concentrations induced notable disturbances in the tube region (≥ 0.25 μM/1 μM for 785 nm/830 nm) suggesting the graduating absorption (320% increase at 785 nm) introduced errors. We observe that 830 nm is lower in the ICG absorption spectrum and the correspondingly measured flow encountered less influence than 785 nm. From these results we anticipate the best practice in future studies to be utilization of a laser source with wavelength in a low region of the ICG absorption spectrum (e.g., 830 nm) or to only monitor flow prior to ICG injection or post-clearance. In addition, ncDCT was initially tested in a mouse tumor model to examine tumor size and averaged flow changes over a four-day interval. The next steps in forwarding the combined device development include the straightforward automation of data acquisition and filter rotation and applying it to in vivo tumor studies. These animal/clinical models may seek information such as simultaneous detection of tumor flow, fluorescence, and absorption contrasts or analyzing the relationship between variably sized fluorescently tagged nanoparticles and their tumor deposition relationship to flow distributions.
117

Développement d’un système de spectroscopie infrarouge résolue temporellement pour la quantification des concentrations d’hémoglobine cérébrale

Leclerc, Paul-Olivier 11 1900 (has links)
L’étude du cerveau humain est un domaine en plein essor et les techniques non-invasives de l’étudier sont très prometteuses. Afin de l’étudier de manière non-invasive, notre laboratoire utilise principalement l’imagerie par résonance magnétique fonctionnelle (IRMf) et l’imagerie optique diffuse (IOD) continue pour mesurer et localiser l’activité cérébrale induite par une tâche visuelle, cognitive ou motrice. Le signal de ces deux techniques repose, entre autres, sur les concentrations d’hémoglobine cérébrale à cause du couplage qui existe entre l’activité neuronale et le flux sanguin local dans le cerveau. Pour être en mesure de comparer les deux signaux (et éventuellement calibrer le signal d’IRMf par l’IOD), où chaque signal est relatif à son propre niveau de base physiologique inconnu, une nouvelle technique ayant la capacité de mesurer le niveau de base physiologique est nécessaire. Cette nouvelle technique est l’IOD résolue temporellement qui permet d’estimer les concentrations d’hémoglobine cérébrale. Ce nouveau système permet donc de quantifier le niveau de base physiologique en termes de concentrations d’hémoglobine cérébrale absolue. L’objectif général de ma maîtrise était de développer un tel système afin de l’utiliser dans une large étude portant sur la condition cardiovasculaire, le vieillissement, la neuroimagerie ainsi que les performances cognitives. Il a fallu tout d’abord construire le système, le caractériser puis valider les résultats avant de pouvoir l’utiliser sur les sujets de recherche. La validation s’est premièrement réalisée sur des fantômes homogènes ainsi qu’hétérogènes (deux couches) qui ont été développés. La validation des concentrations d’hémoglobine cérébrale a été réalisée via une tâche cognitive et appuyée par les tests sanguins des sujets de recherche. Finalement, on présente les résultats obtenus dans une large étude employant le système d’IOD résolue temporellement en se concentrant sur les différences reliées au vieillissement. / Our understanding of the functional organization of the human brain has been greatly influenced by the development of new medical imaging techniques. Pr. Hoge’s research has focused on the use of functional magnetic resonance imaging (fMRI) and continuous diffuse optical imaging (DOI) for non-invasive localization and quantification of brain activity associated with behavioral stimuli or tasks (e.g. cognitive, motor or visual). The respective signals of both techniques are based on cerebral haemoglobin concentrations because of the coupling that exists between neuronal activity and cerebral blood flow. Relating BOLD fMRI signals with those acquired using DOI has been complicated by the fact that fMRI yields fractional change values, while the majority of DOI methods have provided absolute changes from an unknown baseline. To address this, we adopted a newer technique known as time-resolved DOI, which allows absolute quantification of cerebral haemoglobin concentrations. Time-resolved DOI thus has the capacity to quantify the subject’s resting hemoglobin concentrations in absolute micromolar units. The main objective of my masters’ project was to implement and optimize a time-resolved DOI system for use in a large study exploring the links between cardiovascular fitness, aging, neuroimaging markers, and cognitive performance. In this thesis we describe the fabrication of the system, followed by its characterisation and validation using solid optical phantoms (homogeneous and heterogeneous) developed for this purpose. Haemoglobin concentrations obtained non-invasively with the system are validated against blood draws, while the sensitivity to variations in concentration are assessed during a cognitive task. Finally, we present the results of a large study in which the time-resolved DOI system was used to characterize age-related vascular changes in the brain.
118

Caractérisation des états excités de complexes de nickel(II) par spectroscopie de réflectivité diffuse et d'absorption à température variable

Prala, Carmen January 2008 (has links)
Mémoire numérisé par la Division de la gestion de documents et des archives de l'Université de Montréal
119

Tomographie optique diffuse multispectrale résolue en temps / Multispectral time-resolved diffuse optical tomography

Zouaoui, Judy 21 November 2016 (has links)
La possibilité de déterminer précisément et de quantifier la composition des milieux biologiques est un défi pour l'imagerie médicale qui permettrait de diagnostiquer certaines maladies ou de mieux étudier les processus physiologiques. La tomographie optique diffuse (DOT) est une technique d'imagerie attrayante qui permet de façon non invasive, non-ionisante et potentiellement avec une grande spécificité de sonder les milieux en profondeur en utilisant la lumière dans le proche infrarouge et de reconstruire en trois dimensions leur composition. Pour obtenir les caractéristiques des chromophores endogènes (oxy- et désoxy-hémoglobine) enfouis dans un milieu très diffusant, une instrumentation optique dans le domaine temporel et multi-longueurs d'onde combinée à un algorithme de reconstruction en trois dimensions a été développée. Des mesures expérimentales ont été menées en géométrie de réflectance en éclairant avec un laser picoseconde un milieu perturbé (contenant une hétérogénéité) et en récupérant, pour plusieurs longueurs d'onde et multi-positions, la lumière rétrodiffusée via deux fibres optiques connectées à deux détecteurs dédiés et couplés à un système de comptage de photon unique. Le traitement des données de ces mesures résolues en temps a été réalisé en supposant que la propagation de la lumière est gouvernée par l'approximation de la diffusion et en utilisant une méthode basée sur la transformée de Mellin-Laplace. Des simulations et des expériences sur une gamme de milieux imitant les milieux biologiques ont démontré que cette technique médicale a le potentiel pour donner des images médicales quantitatives. Nous avons montré que l'on peut déterminer correctement la composition d'objets à 10 mm de profondeur absorbant faiblement. Pour de plus fortes profondeurs et des absorptions plus élevées, la valeur du coefficient d'absorption ou de la concentration est sous-estimée. En outre, l'imagerie multimodale apporte des améliorations dans la précision de la quantification en profondeur et donc peut être une bonne opportunité pour les futures applications cliniques de la DOT. / In medical imaging, the ability to accurately retrieve and quantify the composition of turbid media is challenging and would enable to diagnose some diseases or to better study physiological processes. Diffuse optical tomography (DOT) is an attractive medical imaging technique which permits to probe in depth using near-infrared light and to reconstruct in three dimensions the composition of biological tissues non-invasively, non-ionizing and with potentially high specificity. To obtain endogenous chromophore (oxy- and desoxy-hemoglobin) features in the depth of a highly scattering medium, a multiwavelength time domain optical setup combined to a three-dimensional reconstruction algorithm was developed. Experimental measurements were conducted in reflectance geometry by illuminating a perturbed medium (with a heterogeneity) with a picosecond laser and by collecting, for several wavelengths and multi-positions, the backscattered light via two fibers connected to two dedicated detectors and coupled to a time-correlated single photon counting system. The data processing of these time-resolved measurements and those of a known reference medium was performed by supposing that the propagation of light is governed by the diffusion approximation and using a method based on Mellin-Laplace transform. Numerical and phantom experiments on series of objects similar to biological media demonstrate that this technique has the potential to give quantitative medical images. We have highlighted a correct quantification for the less absorbing objects at 10 mm depth while underestimation results at deeper depths and higher absorptions. Furthermore, the multimodal imaging brings improvements in quantification in depth and thus it can be a good opportunity to DOT for its future clinical applications.
120

Aspects micromécaniques de la rupture dans les milieux granulaires / Micromechanic Aspects of failure in geomaterials

Hadda, Nejib 18 April 2013 (has links)
Les régions de montagne sont parfois le siège de phénomènes dévastateurs brutaux, tels que les éboulements, les glissements de terrains, ou encore les avalanches. Fondamentalement, ces phénomènes sont issus de la rupture d’un volume de matériau qui va alors s’écouler sous l’effet de son poids propre. Prévoir ces phénomènes impose donc de mieux décrire la phase initiale de rupture. Ce travail de thèse s’inscrit dans cette volonté, en considérant le cas très général de la rupture dans un milieu granulaire. Pour cela, des simulations numériques utilisant une méthode aux éléments discrets ont été mises en œuvre, afin de vérifier la pertinence des critères usuels de rupture et d’instabilité. Dans un second temps, des analyses plus fines basées sur le travail du second ordre calculé à partir des variables microscopiques ont été menées afin de cerner comment évolue la microstructure de l’assemblage granulaire juste avant et pendant la rupture. Finalement, l’influence du chemin de chargement et des paramètres de contrôle sur la nature (effective ou non effective) et le mode (diffus ou localisé) de rupture a été examinée à travers une série d’essais biaxiaux sur deux échantillons numériques bidimensionnels (dense et moyennement dense). / Landslides and avalanches are the most common brutal and devastating natural hazards in mountain regions. Basically, these phenomena are derived from the failure of a material volume which will then flow under the effect of its own weight. Therefore, predicting these phenomena requires a better description of the initial phase of failure. This work comes within this willingness, considering the very general case of failure in granular media. For this purpose, numerical simulations using a discrete element method were carried out in order to investigate the relevance of the common failure and instability criteria. In a second step, more detailed analyses based on the second order work computed from the microscopic variables were conducted in order to describe the evolution of the microstructure of a granular assembly just before and during the failure. Finally, the influence of the loading path and the control parameters on the nature (effective or non-effective) and the mode (diffuse or localized) of failure was discussed through a series of biaxial tests performed on two-dimensional numerical samples depicting respectively a dense and a medium dense dry sand.

Page generated in 0.0458 seconds