• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 483
  • 30
  • 5
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 533
  • 533
  • 323
  • 307
  • 186
  • 85
  • 73
  • 70
  • 65
  • 58
  • 55
  • 47
  • 42
  • 38
  • 37
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
371

Um estudo sobre adaptações para redução do consumo de energia elétrica em sistemas de ar condicionado

COSTA, Clécio 13 January 2016 (has links)
Submitted by Natalia de Souza Gonçalves (natalia.goncalves@ufpe.br) on 2016-09-28T11:56:34Z No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Dissertação_ClecioCosta_final2016_library3.pdf: 3000598 bytes, checksum: eaa89ac5922423ba09bca9160b998bb6 (MD5) / Made available in DSpace on 2016-09-28T11:56:34Z (GMT). No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Dissertação_ClecioCosta_final2016_library3.pdf: 3000598 bytes, checksum: eaa89ac5922423ba09bca9160b998bb6 (MD5) Previous issue date: 2016-01-13 / De acordo com a Associação Brasileira das Empresas de Serviços de Conservação de Energia – ABESCO, no ano de 2014 o Brasil desperdiçou 10% da energia elétrica produzida no país. Aproximadamente 22% dessa energia desperdiçada, correspondem às perdas advindas do consumidor comercial. Ressalta-se que os equipamentos de condicionadores de ar podem chegar a representar 30% desse consumo de energia elétrica. Vale destacar que o escopo principal da proposta deste trabalho é a obtenção da redução do consumo elétrico. Com isso, este trabalho tem como proposta mitigar o consumo de energia elétrica, reduzir os custos, aumentar a vida útil dos equipamentos de condicionadores de ar e evitar desperdícios elétricos. Para isso, foi utilizada a tecnologia Arduino com objetivo de desenvolver uma ferramenta embarcada sensível ao contexto e uma placa de controle que irá substituir a original do equipamento. Estes irão automatizar o funcionamento do sistema de condicionadores de ar e buscar um ganho socioeconômico, fornecendo um melhor serviço ao sistema de refrigeração com um menor consumo energético. A proposta é composta de duas fases: a primeira fase monitora e coleta informações do funcionamento dos equipamentos de condicionadores de ar durante um período de tempo e realiza uma análise dos dados coletados para melhor parametrizar os ajustes aplicados na segunda fase. Esta consiste na substituição da placa de controle original do equipamento pela desenvolvida na proposta deste, juntamente com a ferramenta desenvolvida com todos os ajustes oriundos da análise dos dados. A validação deste trabalho é feita através da aplicação do sistema desenvolvido, por um período de seis meses; complementada pela realização de uma pesquisa de satisfação feita com os usuários. / According to the Brazilian Association of Energy Conservation Service Companies - ABESCO, in 2014 the Brazil wasted 10% of the electricity produced in the country. Approximately 22% of this wasted energy, correspond to losses from the commercial customer. It is noteworthy that the air conditioning equipment can account for up to 30% of electricity consumption. Therefore, this paper aims to mitigate the consumption of electric energy, reduce costs, extend the life of air conditioners electrical equipment and avoid waste. It is worth noting that the main scope of the purpose of this study is to obtain the reduction of power consumption. For this, the Arduino technology was used in order to develop an embedded context-sensitive tool and a control board that will replace the original equipment. These will automate the operation of air conditioners system and seek a socioeconomic gain, providing a better service to the refrigeration system with a lower energy consumption. The proposal consists of two phases: the first phase monitors and collects information of the operation of air conditioning equipment for a period of time and performs an analysis of the data collected to better parameterize the adjustments in the second phase. This involves replacing the original control board equipment developed for the purpose of this, together with the tool developed with all adjustments arising from the data analysis. The validation of this work is done by applying the developed system for a period of six months; complemented by conducting a satisfaction survey of users.
372

Otimização em estação elevatória em sistemas de abastecimento de água buscando a eficiência energética

PEDROSA, Hudson Tiago dos Santos 29 February 2016 (has links)
Submitted by Fabio Sobreira Campos da Costa (fabio.sobreira@ufpe.br) on 2016-10-17T12:44:06Z No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Dissetação-Hudson-OTIMIZAÇÃO EM ESTAÇÃO ELEVATÓRIA DE SISTEM.pdf: 6157352 bytes, checksum: f068bb8afd877ced8f8d15b70cea33af (MD5) / Made available in DSpace on 2016-10-17T12:44:06Z (GMT). No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Dissetação-Hudson-OTIMIZAÇÃO EM ESTAÇÃO ELEVATÓRIA DE SISTEM.pdf: 6157352 bytes, checksum: f068bb8afd877ced8f8d15b70cea33af (MD5) Previous issue date: 2016-02-29 / O crescimento da população vem demandando água em quantidades maiores, o que obriga as empresas de saneamento a encontrarem alternativas técnicas que sejam viáveis economicamente para o déficit de água das áreas urbanas. Na sua maioria essas alternativas modificam o comportamento operacional do sistema de bombeamento, geralmente aumentando o tempo de bombeamento e/ou aumentando os números de conjuntos motor-bomba em funcionamento. Os conjuntos elevatórios são responsáveis pela maior parte do consumo de energia elétrica e embora estes equipamentos sejam necessários para transportar a água através dos sistemas e garantirem a confiabilidade do abastecimento de água, o grande consumo de energia elétrica dificulta o equilíbrio financeiro das empresas de saneamento. Com esta preocupação, o presente estudo apresenta uma otimização na rotina operacional das estações elevatórias, buscando a operação ótima que minimize o custo com energia elétrica e atenda os limites físicos e operacionais envolvidos no sistema elevatório. Aplicando-se a plataforma de otimização em elevatórias reais, obteve-se uma redução na potencia utilizada de 20% se comparada à potência nominal dos conjuntos motor-bomba das estações elevatórias, originando economia de aproximadamente 7% no custo com energia elétrica das unidades. / Population growth has been demanding water in larger quantities, which requires sanitation companies to find alternative techniques that are economically viable for the water shortage in urban areas. These alternatives, in most cases, modify the operational performance of the pumping system, generally increasing the pumping time and / or increasing the number of motor-pump sets in operation. The motor-pump sets are responsible for most of the electricity consumption and although these equipment are needed to transport the water through the system and ensure the reliability of water supply, the large consumption of electricity hinders the financial stability of the sanitation company. With this in mind, this study presents an optimization routine for operating the pumping stations; seeking the optimal operation that minimizes the cost of electricity while also meeting the physical and operational limits involved in the pumping stations. Applying the optimization platform of this study on actual pumping stations, it obtained an average reduction of 20% of the nominal power of the motorpump sets of pumping stations, resulting in savings of approximately 7% in the cost of electric energy of the pumping stations.
373

Análise do uso da energia elétrica em instalações industriais do segmento de alimentos e bebidas / Analysis of electrical energy uses in food and beverages industries

Silva, Roberto Perillo Barbosa da 17 August 2018 (has links)
Orientador: Luiz Antonio Rossi / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecânica / Made available in DSpace on 2018-08-17T20:51:17Z (GMT). No. of bitstreams: 1 Silva_RobertoPerilloBarbosada_M.pdf: 2003113 bytes, checksum: b03934eb470f8966d8a8f19e8d3fc7a5 (MD5) Previous issue date: 2011 / Resumo: A energia elétrica é um insumo com diversas aplicações. No caso industrial, este insumo corresponde a uma parcela daqueles utilizados na produção e, por isso, busca-se, cada vez mais, a racionalização deste tipo de energia, sem que, para isso, seja necessário diminuir o nível de produção, ou prejudicar a qualidade do produto final. No Brasil, o setor industrial é responsável por cerca da metade do consumo final de energia elétrica; logo, ações que visam estimular o uso racional e a conservação de energia elétrica são importantes. Este trabalho teve como objetivo analisar o uso da energia elétrica em instalações industriais do segmento de Alimentos e Bebidas, através de uma amostra situada na região Sudeste do Brasil. O segmento foi escolhido pelo fato de ter grande representatividade, em termos de maiores consumidores de energia elétrica, entre as indústrias do País. Para o desenvolvimento do trabalho, foi aplicado nas instalações industriais um questionário preliminar para identificar dados primários referentes aos processos e sistemas existentes em cada uma delas. Posteriormente, foram realizados diagnósticos energéticos nessas instalações para identificar e quantificar, através de medições em campo, as condições nominais e operativas dos equipamentos e processos e caracterizar a utilização da energia elétrica. Para a realização das medições, utilizou-se o Guia Nacional de Medição e Verificação (M&V) da Eletrobrás/PROCEL, para padronizar as análises. Portanto, através da medição em campo, determinou-se para cada instalação industrial analisada, indicadores de eficiência energética, como o fator de carga, o consumo específico e o preço médio da energia. Também foi realizada a análise do enquadramento tarifário das instalações, com o intuito de verificar se as condições atuais de contratação e fornecimento de energia elétrica consistem nas mais adequadas para o perfil de cada uma delas. Constatou-se através das medições e da análise do enquadramento tarifário que, apesar das instalações já terem equipes que realizam algum tipo de monitoramento do uso da energia elétrica, em muitos casos ainda se tem oportunidades para a racionalização do uso da energia elétrica. E mais, sugere-se que seja realizado um estudo de prospecção tecnológica, pois cada vez mais há o surgimento de novos processos e/ou equipamentos mais eficientes, podendo aumentar ainda mais o potencial para a otimização do uso da energia elétrica. No Brasil existem atualmente linhas para financiamento, visando à eficiência energética, além de empresas que prestam serviço e financiam a implantação destas ações (as chamadas ESCOs), sendo ressarcidas através das economias obtidas. Por isso a importância de trabalhos que enfatizam a viabilidade de ações visando aumentar a eficiência energética nos processos e equipamentos, pois ainda há grande aversão ao risco por parte dos empresários / Abstract: Electrical energy is an input with many applications. In industries, this input corresponds to a considerable portion utilized in the production and for this reason, it is demanded ways to save energy without decreasing the production or cause no prejudice to final product quality. In Brazil, industries consume about half of the electrical energy utilized in the industrial sector therefore it is important to study actions that intend to stimulate rational use of energy and its conservation. The current study aims to analyze electrical energy uses in food and beverages industry installations through a sample located in Southeast region of Brazil. These segments of industry have been chosen because they have highly representative as the largest consumers of electrical energy in the country. For the developing of the research, it was applied preliminary questions in industrial installations intending to identify primary data relating to process and systems in each industry. Afterwards, it was realized energy diagnosis to identify and quantify, through field measures, the nominal and operatives conditions of equipments and process besides characterize the uses of energy. For the measures data collection and standard the analysis, it has been used the National Guide of Measurement and Verification (M&V) from Eletrobrás/PROCEL. Therefore, through the measurement in industries, it was determined for each industry installation analyzed, energy efficiency indicators as charge factor, specific consumption and energy average price. In addiction, it was achieved the charging system analysis of installations, with purpose of verifying if the current conditions of contractation and energy supply consists in the most appropriate profile for each industry. It was verified through measurement and charging system analysis that in spite of the installations have already had staffs responsible for monitoring the uses of electricity, in most situations, there are still opportunities to avoid electrical energy waste. Furthermore, this current research proposes a study of technological prospecting, because more and more most efficient equipments and new process are emerging, increasing the potential to optimize the uses of electrical energy. In Brazil, there are researches funding aiming energy efficiency, besides several companies providing service and financing the implementation of these actions (known as ESCOs) and they are compensated through saving costs. For this reason, researches that emphasizes energy efficiency on equipments and process are very important because industry community has had risk aversion yet / Mestrado / Engenharia Mecanica / Mestre em Planejamento de Sistemas Energéticos
374

Otimização do processo de spray drying pelo uso de pré-desumidificadores no ar de entrada

Alex Notaroberto Madeira 07 November 2009 (has links)
Spray Drying é um processo de secagem por atomização em uma câmara fechada, que visa retirar a umidade de um produto por transferência de calor e massa de água contida no produto para o ar que é previamente aquecido neste processo. Este trabalho apresenta um estudo de caso para uma indústria que produz aditivos alimentícios. O ar de entrada pode chegar à câmara com alta umidade proveniente da atmosfera, neste caso, haverá mais consumo de energia de acordo com as estações do ano. Esta pesquisa promove um estudo do processo atual, através da instalação de um equipamento de pré-desumidificação no ar de entrada do processo e mostra diferentes sistemas de desumidificação: por refrigeração e por adsorção, comparando os desempenhos sob o ponto de vista energético, ambiental e econômico com sistema original. Os objetivos deste estudo são analisar a capacidade de remoção de umidade de cada dispositivo de desumidificação, a influência de cada dispositivo e a variação da umidade do ar de entrada no processo, bem como o impacto econômico e ambiental de cada equipamento no sistema global. Além disso, promove o aumento do gradiente de umidade entre o ar de entrada e do produto otimizando o processo de secagem, aumentando a eficiência energética global do sistema e reduzindo o impacto ambiental. / Spray drying is a dehumidification process by atomization in a closed chamber that aims to remove moisture of a product by heat and mass transfer from the contained water in the product to the air which is previously heated in this process. This paper presents a case study for an industry that produces food ingredients. The inlet air can reach the chamber with high moisture from the atmosphere condition requesting, in this case, more energy consumption according to the seasons of the year. This paper promotes a study of the current process through the installation of a pre-dehumidification device of the inlet air and shows different dehumidification systems: The refrigeration and the adsorption and comparing their performance in an energetic, environmental and economic point of view. The goals of this study are to analyze the capacity of moisture removing of each dehumidification device, the influence of moisture variation of the inlet air in the process as well as the economic impact of each device in the global system. Moreover, it promotes the increasing of moisture gradient between the inlet air and the product optimizing the drying process, increasing the global energy efficiency in the global system and reducing environmental impact.
375

A auditoria energética como ferramenta para o aproveitamento do potencial de conservação da energia: o caso das edificações do setor educacional / The energy audit as a tool for harnessing the potential for energy conservation: the case of education sector buildings

Jose Rafael Rodriguez Benavides 27 May 2014 (has links)
O consumo de energia nos diferentes setores da economia cresce continuamente devido aos hábitos de consumo, aumento da população e necessidades tecnológicas atuais; considerando o efeito deste aumento de consumo sobre os recursos naturais, a conscientização da importância do uso racional da energia é cada dia um tópico de maior relevância em todo o mundo. Ante a crescente necessidade de reduzir o consumo energético das edificações, algumas metodologias apresentam-se como ferramentas úteis para o alcance deste fim, uma delas é a auditoria energética. A auditoria energética é um mecanismo para entender o desempenho energético de edifícios, através dela é possível detectar problemas operacionais, aumentar o conforto dos ocupantes e otimizar o uso da energia. O presente estudo utilizou uma metodologia de auditoria energética para conhecer o comportamento energético de diferentes prédios do setor terciário especificamente do setor educacional, pertencentes a Universidade de São Paulo (USP). A metodologia foi aplicada em diferentes edificações do setor, e a mesma incluiu a utilização de medições de variáveis elétricas, medições de iluminação segundo as normas preconizadas, software para estudo de usos finais e ferramentas de simulação computacional como o software Dialux e o EnergyPlus. As melhores oportunidades de eficiência energética foram avaliadas técnica e economicamente, comparando cenários para a execução de estratégias com diferentes tecnologias comercialmente disponíveis no mercado. A avaliação econômica incluiu a utilização de figuras de mérito como o tempo de payback, a taxa interna de retorno (TIR), o custo de ciclo de vida (LCC), o custo de ciclo de vida anualizado (ALCC) e o custo da energia conservada (CEC). Os resultados validam a auditoria energética como método para tomada de decisões no sentido de eleger as melhores ações de eficiência energética para uma edificação. / The energy consumption in different sectors of the economy grows continuously due to consumption habits, increase in population and current technological needs; considering the negative effect of this increased consumption the environment, awareness of the significance of rational use of energy is a topic of great importance worldwide. Faced with the growing need to optimize the energy consumption of buildings, some methodologies are presented as useful tools for achieving this goal, one of them is the energy audit. The energy audit is a mechanism to understand the energy performance of buildings and facilities, through it is possible to detect operational problems , increase occupant comfort and optimize energy use. The present study used a methodology of energy audit to understand the energy performance of different buildings of the tertiary sector and specifically in educational sector buildings belonging to the University of São Paulo ( USP ) . The methodology was applied in different buildings of this sector , and it included the use of power measurements, lighting measurements according to the standards, energy end-use software and computer simulation tools such as Dialux and EnergyPlus software .The best opportunities for energy efficiency were evaluated by comparing scenarios for the implementation of strategies with different technologies commercially available. The economic evaluation included the use of financial analysis tools such as payback time , the internal rate of return (IRR ) , the Life Cycle Cost (LCC) , the Annualized Life Cycle Cost (ALCC) and the Cost of Saved Energy (CSE) . The results validate energy audit as a method for decision making in order to select the best energy efficiency strategies for a building.
376

Otimização de sistemas de irrigação por aspersão pivô central / Optimization of system center pivot sprinkler irrigation

MEDEIROS, Antonio Marcos de Melo 26 February 2010 (has links)
Made available in DSpace on 2014-07-29T14:52:05Z (GMT). No. of bitstreams: 1 Tese Antonio Marcos 25022010.pdf: 1893079 bytes, checksum: 7678a19648ddfd55dd2c6b7a3ecaa4fd (MD5) Previous issue date: 2010-02-26 / It has been noticed lately that some regions of Brazil has presented lower supplying of water and energy. It has occurred mainly during the period of the year when it is higher the need for irrigation water. It is necessary to recognize the possibility of negative impacts of irrigation, to analyze them and present solutions so as to improve the irrigation systems. The aim of this study is the estimation by one system of irrigating the central pivot, breaking from the characteristics of this systems and considering the analyzed of varies combinations of pipes for water main and lateral line, choice of the set motor pump with major yield, utilization and comparison among motor standard and of high yield after the selection from best option in diameter from water main and lateral line, analyze the system using a variable frequency drives. The result with the calculations performed was an energy saving of 25% considering the use of the diameter for the two economic systems adopted. For analysis using a frequency inverter with resulted in a saving of 9.23% for center pivot irrigation system exists, and for the new center pivot irrigation system resulted in savings of 10.6%. The analysis of return on investment considering the use of the system with variable frequency drive was a rate of return on investment of 6.52% pa, center pivot irrigation system for existing and center pivot irrigation system was again 9.48 % pa. The project's return, more long-term, or feasible in the short term, considering the benchmark interest rate to 12.25% pa. The results presented in the study show that there is great potential for power savings, and economic analysis showed the feasibility of the system with return on invested capital. The calculation used for determining the center pivot irrigation system reduces the cost and time to obtain data that make analysis of the potential of saving electricity. / Ultimamente vem percebendo com mais intensidade, a escassez de água e energia elétrica em algumas regiões do país. Esta observação ocorreu justamente no período do ano quando existe a maior necessidade de demanda de água das culturas irrigadas. A necessidade de reconhecer a possibilidade de ocorrência de impactos negativos do uso da irrigação, avaliando-os e desenvolvendo soluções tecnológicas que provoquem melhorias, viabilizando a atividade agrícola irrigada, de forma adequada. Este trabalho teve por objetivo a otimização de um sistema de irrigação pivô central, partindo das características desse sistema e considerando a análise de várias combinações de tubos para a adutora e linha lateral; escolha do conjunto motobomba com maior rendimento; utilização e comparação entre motor padrão e de alto rendimento, após a escolha da melhor opção de diâmetro da adutora e linha lateral, aná lise do sistema utilizando inversor de frequência. A metodologia adotada consistiu na otimização de dois sistemas de irrigação pivô central um existente no local e outro considerando um sistema de irrigação pivô central novo projetado para atender determinada lamina d água. Para os dois sistema de irrigação pivô central foi considerando a análise econômica do diâmetro das tubulações que compõem o sistema de irrigação a pivô central, analisando varias configurações de diâmetros diferentes, rotações do conjunto moto bomba, utilização de motores de alto rendimento e padrão, uso do inversor de freqüência. O resultado com os cálculos realizados foi uma economia de energia elétrica de 25% considerando o uso do diâmetro econômico para os dois sistemas adotados. Para análise com uso inversor de frequência com, resultou em uma economia de 9,23% para o sistema de irrigação pivô central existente, e para o novo sistema de irrigação pivô central resultou em uma economia de 10,6%. A análise do retorno do investimento considerando o uso do sistema com inversor de frequência foi de uma taxa de retorno do investimento de 6,52% a.a, sistema de irrigação pivô central existente e para o sistema de irrigação pivô central novo foi de 9,48% a.a. O projeto tem retorno, mas de longo prazo, ou seja, inviável em curto prazo, considerando a taxa básica de juro com 12,25% a.a. Os resultados apresentados no trabalho mostram que há um grande potencial de economia de energia elétrica, e a análise econômica mostrou a viabilidade do sistema com retorno do capital investido. O cálculo utilizado para a determinação do sistema de irrigação pivô central diminui o custo e o tempo para obtenção de dados que compõem a análise do potencial de economia de energia elétrica.
377

Análise de desempenho térmico e consumo de energia estudo de caso em hotelaria / Análise de desempenho térmico e consumo de energia estudo de caso em hotelaria / Building Eficiency Analysis - hotelery studie / Building Eficiency Analysis - hotelery studie

PINTO, Maryana de Souza 03 October 2008 (has links)
Made available in DSpace on 2014-07-29T15:01:49Z (GMT). No. of bitstreams: 1 ANALISE DE DESEMPENHO TERMICO E CONSUMO DE ENERGIA.pdf: 2876854 bytes, checksum: b75101546f341505c1e7c98ce72bea56 (MD5) Previous issue date: 2008-10-03 / This study, concerns the area of Recursos Hídricos e Saneamento Ambiental, and investigates how internal and external temperature effects the comfort in a hotel building , which has multiple functions and different levels of users. It is aimed to check the thermal performances, considering the surrondings , the activities of the users, their preferences and possibilities of heat acclimatization, the final use and habits of consumption of electric energy. As a theoretical framework for this task, it uses by choice bioclimatic architecture , an area that concerns the construction focused on greater energy efficiency and comfort. The verification of environmental suitability offered in different environments evaluated, took advantage of the studies of Fanger (1970), suggested by ISO -7730 (1995), ISO-9920 (1995) and ASHRAE (1992), as well as questionnaires answered by users of the building. Thus proceeded to study the urban characterization of the city of Rio Quente; the survey and selection of the building for the Case Study; selection of sites for measurement, data collection, analysis and comparison of results with Thermal Comfort indexes suggested by Fanger (1970). The environments selected followed the criteria for critical positioning in line with the direction of longer periods of solar direct impact on the facades, the burden of occupation, the direct and ventilation equipment. This case study used five sets of comfort measuring devices, to obtain Dry Bulb Temperature (DBT) and Radiant Thermal Load (RTL) and Air Relative Humidity (ARH) . Data was collected internally and externally from the building in aim to verify the behaviour of this construction , and after the external data was compared to the data provided by the Plataforma de Coleta de Dados (PCD) of Serra de Caldas, for checking the quality of data available for designers. The analysis showed the best confort perfomance in the Accomodation Areas where, despite no possibility of acclimatization due to the short periods of stay , there was a significant response from the guests . The Common Area also showed satisfactory results in terms of this group of users, due to the characteristics of their clothing and metabolism which in itself merits this project. The worst performance took place in the Services Sector, which presented no conditions of comfort and stayed outside of Fanger´s scale during most of the day, subjecting users to discomfort, this shows that this group of users,workers, are not considered in the early stages of the project. / O presente estudo, compreendido na área de concentração Recursos Hídricos e Saneamento Ambiental, investiga o conforto térmico em um edifício destinado a atividade hoteleira com múltiplas funções e com diversos níveis de usuários. Objetivou verificar o desempenho térmico, considerando suas condições, o conforto dos usuários, suas preferências térmicas e possibilidades de aclimatação,o uso final e os hábitos de consumo de energia elétrica. Como referencial teórico para tal tarefa, fez-se opção pela arquitetura bioclimática que se preocupa com a construção de ambientes com maior eficiência energética e conforto térmico. A verificação da adequação ambiental proporcionada nos diversos ambientes avaliados valeu-se dos estudos de Fanger (1970), sugeridos pela norma ISO -7730 (1995), ISO-9920 (1995) e ASHRAE (1992), bem como por questionários respondidos pelos usuários dos ambientes. Dessa forma procedeu-se à caracterização urbana do município de Rio Quente; ao levantamento e seleção do edifício para o Estudo de Caso; seleção dos locais de medição; coleta de dados; análise dos resultados obtidos e comparação com Índices de Conforto Térmico sugeridos por Fanger (1970). Os ambientes selecionados obedeceram aos critérios de posicionamento crítico em função da orientação, de maiores períodos de incidência solar direta sobre as fachadas, a carga de ocupação, os equipamentos e a ventilação direta. Foram utilizados cinco conjuntos de confortímetros compostos cada um por um termômetro de globo negro, um anemômetro digital e um psicrômetro de ventilação natural para a obtenção dos valores de temperatura de globo negro, velocidade do vento e umidade relativa do ar, respectivamente. Para as medições de temperatura ambiente foram utilizados os termômetros de bulbo seco (escalas de -10°C a 110°C) existentes nos psicrômetros de ventilação natural. Os dados foram coletados interna e externamente ao edifício de maneira a se verificar o desempenho térmico do mesmo, sendo que os dados externos foram comparados aos registrados pela Plataforma de Coleta de Dados (PCD) da Serra de Caldas, para a verificação da qualidade dos dados disponíveis para os projetistas. A análise apontou um melhor resultado no Setor de Hospedagem aonde, apesar da não possibilidade de aclimatação em virtude do pequeno tempo de permanência e da grande relação com a temperatura externa, houve uma resposta de conforto bastante significativa de seu único grupo de usuários, os hóspedes. O Setor Social também apresentou resultado satisfatório do ponto de vista dos usuários hóspedes, muito mais por suas características de vestimenta e metabolismo que por méritos do próprio projeto. O pior ambiente foi o Setor de Serviços, pois não apresentou condições de conforto e ficou fora da faixa da escala de Fanger durante grande parte do dia, submetendo seus usuários ao desconforto, isso denota que os usuários que trabalham nos edifícios hoteleiros não são considerados importantes nas etapas iniciais do projeto.
378

Estudo de ciclo de vida de gerador eólico de pequeno porte utilizado em propriedade rural / Life cycle analysis of small scale wind generator used in rural property

Miranda, Amauri Ghellere Garcia 15 March 2018 (has links)
Submitted by Edineia Teixeira (edineia.teixeira@unioeste.br) on 2018-09-27T13:18:55Z No. of bitstreams: 2 Amauri_Miranda_2018.pdf: 7286389 bytes, checksum: 230caf9d354bcf9dae841f95c74ace52 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2018-09-27T13:18:55Z (GMT). No. of bitstreams: 2 Amauri_Miranda_2018.pdf: 7286389 bytes, checksum: 230caf9d354bcf9dae841f95c74ace52 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2018-03-15 / Technological advances seek to; somehow, improve the quality of life of the population. To ensure sustainability in new projects and methodologies are established. Among these methodologies to life cycle, assessment seeks to evaluate the energy cost and the environmental impact of a product. Thus, the present work had as purpose to carry out such analysis in a wind turbine installed in the project House, situation at the State University of Western Paraná UNIOESTE, Paraná, Brazil. The energy cost was checked following ISO 14040 and methodology the following methodology was verified energy return proposed by Manwell, 2010. This was exploratory research of bibliographic source. The weather data used to verify the energy return of the generator were actual data, provided by SIMEPAR. In this way, it was found that the energy cost of the material, used in the wind turbine, was 803 MJ. The environmental impact of wind turbine rated at this research, converted to CO2 equivalent, is 60 kgCO2. The capacity of power generation of the wind turbine, to weather conditions found at the scene of the analysis is of 1390 MJ/year when generating power at 12V current and 1278 MJ/year when at 24V.The analysis found that the energy embodied payback time of the wind turbine running at 12V is 11 months and 18 days and at 24V is 1 year and 18 days respectively. / Avanços tecnológicos buscam formas de melhorar a qualidade de vida da população. Para garantir a sustentabilidade em novos projetos parâmetros e metodologias são estabelecidas. Dentre estas metodologias a Análise de Ciclo de Vida busca avaliar o custo energético e o impacto ambiental de um determinado produto. Desta forma, o presente trabalho teve como propósito realizar tal análise em um aerogerador instalado no Projeto Casa, situação na Universidade Estadual do Oeste do Paraná UNIOESTE, Paraná, Brasil. O custo energético foi verificado seguindo metodologia ISO 14040, mensurado em MJ, e o retorno energético foi verificado seguindo metodologia proposta por Manwell, 2010. Esta foi pesquisa exploratórias de fonte bibliográfica. Os dados meteorológicos utilizados para verificar o retorno energético do gerador foram dados reais, fornecidos pelo SIMEPAR. Desta forma, verificou-se que o custo energético do material, empregado no aerogerador, foi 803 MJ. O impacto ambiental do aerogerador avaliado na pesquisa, convertido em CO2 equivalente, é de 60 kgCO2. A capacidade de geração de energia do aerogerador, para as condições meteorológicas encontradas no local da análise é de 1390 MJ/ano quando gerando energia a corrente de à 12V e 1278 MJ/ano quando à 24V. A análise constatou que o tempo de payback energético do aerogerador funcionando a 12V é de 11 messes e 18 dias e a 24V é de 1 ano e 18 dias respectivamente
379

Conservação de energia elétrica: um enfoque em consumidores residenciais / CONSERVATION OF ELECTRIC ENERGY AN APPROACH IN RESIDENTIAL CONSUMERS

Silva, Paulo Roberto Mendes da 25 April 2008 (has links)
Made available in DSpace on 2016-08-17T14:52:47Z (GMT). No. of bitstreams: 1 Paulo_Roberto_Mendes_da_Silva.pdf: 1374075 bytes, checksum: 8f79ce8e82802a104101889982e3089e (MD5) Previous issue date: 2008-04-25 / This work investigates the most used forms of electric energy conservation, especially in Brazil, without neglecting the power quality aspect, emphasizing residential loads. Among the investigated issues, the technological is a very important one since it comprises the application of efficient equipment. However, it is not forgotten the human actions, with great application in the residential point of view. Power quality practical studies involving lightning residential loads are also presented. These studies were carried out with a lab prototype capable of simulating power quality problems, such as momentary and long-term voltage sags. Electrical parameters were monitored trough a power quality analyzer equipment - DRANETZ 4300. The results show that the consumer may not acquire a product (compact efficiency light in this case) according to the manufacturer specifications, being very far from the label specifications. The main objective was, therefore, to study the efficiency energy concepts actions and energy savings, associating them to the cost reduction related to electrical energy and the continuous improvement in cost management taking into account the power quality aspect. / O presente trabalho investiga as formas de conservação de energia elétrica mais utilizadas, especialmente no Brasil, sem esquecer o aspecto da qualidade da energia fornecida enfatizando o setor residencial. Dentre as linhas investigadas, destaca-se a tecnológica, que abrange a aplicação de equipamentos mais eficientes, mas não são esquecidas as ações humanas, com grande penetração especialmente no setor residencial. Estudos práticos de qualidade de energia elétrica envolvendo cargas residenciais de iluminação supostamente eficientes também são apresentados. Esses estudos foram realizados num protótipo de laboratório capaz de simular fontes de problemas de qualidade de energia, como afundamentos momentâneos e de longa duração de tensão. Grandezas elétricas foram monitoradas através de um equipamento analisador de qualidade de energia elétrica DRANETZ 4300. Os resultados mostram que o consumidor pode não adquirir um produto (lâmpada compacta, nesse caso) de acordo com as especificações do fabricante, estando muito abaixo do prometido. O objetivo geral foi, portanto, estudar os conceitos de ações voltadas à eficiência energética e ao combate ao desperdício de energia, vinculando-os à redução de custos relacionados à energia elétrica e à melhoria contínua no gerenciamento dos custos observando-se o aspecto da qualidade de energia.
380

Otimização da relação custo benefício de projetos de eficiência energética do tipo baixa renda

Mota, Jorge Felipe Barbosa 09 September 2016 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-03-10T13:26:21Z No. of bitstreams: 1 jorgefelipebarbosamota.pdf: 2249566 bytes, checksum: 432c0da8b02f3dd942bb9fb9af4add75 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-03-13T18:36:13Z (GMT) No. of bitstreams: 1 jorgefelipebarbosamota.pdf: 2249566 bytes, checksum: 432c0da8b02f3dd942bb9fb9af4add75 (MD5) / Made available in DSpace on 2017-03-13T18:36:13Z (GMT). No. of bitstreams: 1 jorgefelipebarbosamota.pdf: 2249566 bytes, checksum: 432c0da8b02f3dd942bb9fb9af4add75 (MD5) Previous issue date: 2016-09-09 / As concessionárias de energia são obrigadas a aplicar parte de sua receita operacional líquida na execução de projetos de eficiência energética, de acordo com a Agência Nacional de Energia Elétrica (ANEEL). O projeto do tipo baixa renda é parte desse portfólio de projetos possíveis e capta a maior parte dessa aplicação. Dessa forma, torna-se de suma importância a criação de uma metodologia para dimensionar os projetos dessa tipologia e direcionar as tomadas de decisões das concessionárias de energia do Brasil. Métodos de otimização bioinspirados tratam de problemas combinatórios e não lineares, caso do equacionamento matemático do cálculo da relação custo benefício de projetos de eficiência energética de tipologia baixa renda. O presente trabalho propõe a aplicação de dois métodos de otimização reconhecidos, a otimização por colônia de formigas, ou Ant Colony Optimization (ACO), e a otimização por enxame de partículas, ou Particle Swarm Optimization (PSO), para calcular e otimizar a relação custo benefício de projetos de eficiência energética regulatórios do tipo baixa renda. Sendo assim, aplica métodos computacionais bioinspirados no dimensionamento dos projetos de eficiência energética, além de otimizar esses projetos, obtendo o melhor resultado operacional, do ponto de vista da eficiência energética, com o melhor custo para a sociedade. / The electricity utilities are required to invest part of its net operating income in the implementation of energy efficiency projects, according to the National Electric Energy Agency (ANEEL). The low-income type design is part of portfolio of possible projects and captures most of this application. Thus, it becomes very important to create a methodology to scale projects of this type and direct decision making of utilities in Brazil. Bioinspired optimization methods deal with combinatorial and nonlinear problems, if the mathematical equations for calculating the cost benefit rate of energy efficiency projects in low-income type. This paper proposes two recognized bioinspired optimization methods, the Ant Colony Optimization (ACO) and the Particle Swarm Optimization (PSO) to calculate and optimize the cost effectiveness of energy efficiency regulatory projects, the low-income type. Thus, propose a scientific methods of sizing of the energy efficiency projects, while optimizing these projects, obtaining the best operating result, from the point of view of energy efficiency with the best cost to society.

Page generated in 0.0525 seconds