• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 346
  • 4
  • Tagged with
  • 350
  • 350
  • 199
  • 195
  • 138
  • 123
  • 118
  • 94
  • 89
  • 67
  • 54
  • 52
  • 50
  • 47
  • 47
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
171

SFPT neural: nova tÃcnica de segmentaÃÃo de fissuras pulmonares baseada em texturas em imagens de tomografia computadorizadas do tÃrax / SPFT neural: novel segmentation technique of pulmonary fissures based on textures in computerized tomography images of the chest

Edson Cavalcanti Neto 19 December 2014 (has links)
Conselho Nacional de Desenvolvimento CientÃfico e TecnolÃgico / Entre todos os tipos de cÃncer, o de pulmÃo (CP) à um dos mais comuns de todos os tumores malignos, apresentando aumento de 2% por ano na sua incidÃncia mundial. No Brasil, para o ano de 2014 sÃo estimados 27.330 casos novos de CP, sendo destes 16.400, em homens e 10.930 em mulheres. Neste contexto, à de fundamental importÃncia para saÃde pÃblica realizar e determinar diagnÃsticos precoces e mais precisos para detectar os estÃgios reais das doenÃas pulmonares. O auxÃlio ao diagnÃstico mostra-se importante tanto do ponto de vista clÃnico quanto em pesquisa. Dentre os fatores que contribuem para isto, pode-se citar o aumento da precisÃo do diagnÃstico do mÃdico especialista à medida que aumenta o nÃmero de informaÃÃes sobre o estado do paciente. Deste modo, certas doenÃas podem ser detectadas precocemente, aumentando as chances de cura. O tratamento inicial para esta doenÃa consiste na lobectomia. Nesse contexto, costuma-se realizar a segmentaÃÃo dos lobos pulmonares em imagens de Tomografia Computadorizada para extrair dados e auxiliar no planejamento da lobectomia. A segmentaÃÃo dos lobos a partir de imagens de TC à geralmente obtida atravÃs da detecÃÃo das fissuras pulmonares. Nesse sentido, com o intuito de obter uma segmentaÃÃo da fissura pulmonar mais eficaz e realizar um processo totalmente independente das demais estruturas presentes no exame de TC, o presente trabalho possui o objetivo de realizar a segmentaÃÃo das fissuras utilizando medidas de textura LBP e Redes Neurais Artificiais (RNA). Para a implementaÃÃo do algoritmo foi utilizado uma MLP (Multilayer Perceptron) com 60 entradas, 120 neurÃnios na camada oculta e 2 neurÃnios de saÃda. Os parÃmetros de entrada para a rede foi o histograma LBP do voxel a ser analisado. Para o treinamento da rede foi necessÃrio criar um sistema para identificaÃÃo das classes fissuras e nÃo-fissuras de forma manual, onde o usuÃrio seleciona os pixels da classe fissura e da nÃo-fissura. Para realizar as validaÃÃes do algoritmo foi criado um padrÃo-ouro que foi extraÃdo um total de 100 imagens de 5 exames do banco de dados LOLA11. Nessas imagens, as fissuras foram destacadas por 2 especialistas. A partir do padrÃo-ouro, o as imagens foram processadas pelo algoritmo e assim os resultados obtidos. Para o conjunto de imagens testadas, o classificador obteve um melhor desempenho quando o tamanho, 15x15 pixels, da janela utilizada para gerar o histograma do LBP. Para chegar atà essa definiÃÃo foram testados os tamanhos 11x11, 15x15, 17x17 e 21x21 e os resultados foram comparados utilizando as mÃtricas de Especificidade Es(\%), Coeficiente de Similaridade CS(%), Sensibilidade S(\%), distÃncia mÃdia e desvio padrÃo da distÃncia. A primeira abordagem de anÃlise dos resultados à atravÃs dos voxels}definidos como fissura no final da metodologia proposta. Para a metodologia proposta, detecÃÃo automÃtica utilizando LBP ( extit{Local Binary Pattern}) e MLP, as taxas obtidas foram CS = 96,7%, S = 69,6% e Es = 96,8% para o mÃtodo proposto antes do afinamento e CS = 99,2%, S = 3% e Es = 99,81% para o mÃtodo proposto com o afinamento no fim, considerando a incidÃncia de falsos positivos e falsos negativos. Outra abordagem utilizada na literatura para avaliaÃÃo de mÃtodos de segmentaÃÃo de fissuras à baseado na distÃncia mÃdia entre a fissura delineada pelo especialista e a fissura resultante do algoritmo proposto. Desta forma, o algoritmo proposto neste trabalho foi comparado com o algoritmo de Lassen(2013) atravÃs da abordagem da distÃncia mÃdia entre a fissura segmentada manual e a fissura segmentada de forma automÃtica. O algoritmo proposto com afinamento no final obteve uma menor distÃncia no valor de e um menor desvio padrÃo comparado com o mÃtodo de Lassen(2013). Por fim, sÃo apresentados os resultados da segmentaÃÃo automÃtica das fissuras pulmonares. A baixa incidÃncia de detecÃÃes falso negativas, juntamente com a reduÃÃo significativa de detecÃÃes falso positivas, resultam em taxa de acerto elevada. Conclui-se que a tÃcnica de segmentaÃÃo de fissuras pulmonares à um algoritmo Ãtil para segmentar fissuras pulmonares em imagens de TC, e com o potencial de integrar sistemas que auxiliem o diagnÃstico mÃdico. / Among all cancers, lung cancer (LC) is one of the most common tumors, an increase of 2% per year on its worldwide incidence. In Brazil, for the year of 2014, 27,330 new cases of LC are estimated, these being 16,400 in men and 10,930 in women. In this context, it is of fundamental importance for public health the identication on early stages of lung diseases. The diagnosis assistance shows to be important both from a clinical standpoint as in research. Among the factors contributing to this scene, one important is the increasing accuracy of diagnosis of a medical expert as you increase the number of information about the patient's condition. Thus, certain disorders might be detected early, including saving lives in some cases. The initial treatment for this disease consists of lobectomy. In this context, it is customary to perform the segmentation of lung lobes in CT images to extract data and assist in planning for lobectomy. The segmentation of the lobes from CT images is usually obtained by detection of pulmonary fissures. Thus, in order to obtain a more effective segmentation of pulmonary fissures, and perform a completely independent process from the other structures present in the CT scan, the present work has the objective to perform the fissure segmentation using LBP texture measures and Neural Networks (NN). To implement the algorithm we used one MLP with 60 inputs, 120 hidden neurons and 2 output neurons. The input parameters for the network was the LBP histogram of the voxel being analyzed. For network training, it was necessary to create a system to label the features as fissures and non-fissures manually, where the user selects the fissure pixels class. To perform the validation of the algorithm was necessary to create a "gold standard"in which it was extracted a total of 100 images from 5 exams from the dataset LOLA11, where these images were the fissures were highlighted by two experts. From the gold standard, the proposed algorithm was processed and the results were obtained. For all tested images, the classifier obtained a better performance when the size of 15x15 pixels of the window was used to generate the histogram of the LBP. To get to this definition were tested sizes of 11x11, 15x15, 17x17 and 21x21 and the results were based on metrics comaprados ACC (%), TPR (%), SPC (%) distance mean and standard deviation of the distance. The first approach to analyze the results is through the voxels defined as fissure at the end of the proposed methodology. For the proposed methodology, using automatic detection and MLP LBP before thinning, the rates were obtained ACC= 96.7 %, TPR = 69.6 % and SPC = 96.8 % and ACC = 99 2 % TPR = 3 % and SPC = 99.81 % for the proposed method with the thinning in the end, considering the incidence of false positives and false negatives. Another approach used in the literature for evaluating methods of fissure segmentation is based on the average distance between the fissure delineated by the expert and the resulting fissure through the algorithm. Thus, the algorithm proposed in this paper was compared with the algorithm Lassen et al. (2013) by the average distance between the manual segmented and the automatically segmented fissure. The proposed algorithm with the thinning in the end achieved a shorter distance average value and a lower standard deviation compared with the method of (LASSEN et al., 2013). Finally, the results obtained for automatic segmentation of lung fissures are presented. The low incidence of false negative detections detection results, together with the significant reduction in false positive detections result in a high rate of settlement. We conclude that the segmentation technique for lung fissures is a useful target for pulmonary fissures on CT images and has potential to integrate systems that help medical diagnosis.
172

Sistema RFID complementar de piso tátil para localização de deficientes visuais em ambientes fechados

Araujo, Renato Pereira de 02 March 2015 (has links)
Made available in DSpace on 2016-04-27T17:05:59Z (GMT). No. of bitstreams: 1 Renato Pereira de Araujo.pdf: 1711666 bytes, checksum: b5ad19e844d9c137553ad64b03b603c7 (MD5) Previous issue date: 2015-03-02 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / For the visually impaired, identify which path to follow to reach the desired destination without assistance from healthy people is a challenge. To move in an unknown environment is required to interact with the mechanisms of information. However the visually impaired do not yet have a navigation system in indoor environments with real-time response that allows this this communication. This paper presents a device that allows interaction with the tactile floor to aid navigation and orientation. Through an audio interface, the device provides the visually impaired relevant information on the space around it and the navigation options available. The relevant information is disseminated using labels with radio frequency identification technology, integrated into a microcontroller and an audio playback card. Each label has an electronic product code that allows to identify it uniquely. The label installed in a standard place of tactile floor is linked to an audio file with information about the space and the available routes. The reader integrated development board reads the labels and sends the electronic code to the microcontroller, which in turn identifies the code and assigns this audio file to be played. The device was tested by a volunteer who found all labels positioned on the floor tactile alert, clearly identified its position and reached the desired destination without route errors. Used as a complement to tactile signage, this device provides an interaction between the visually impaired and the existing tactile signage. This project will directly contribute to society, providing a convenient navigation system for people with visual disabilities have greater autonomy / Para os deficientes visuais, identificar qual caminho deve ser seguido para chegar ao destino desejado, sem auxílio de pessoas hígidas, é um desafio. Para se deslocar em um ambiente desconhecido é necessária a interação com os mecanismos de informação. Entretanto os deficientes visuais ainda não contam com um sistema de navegação em ambientes internos com resposta em tempo real que possibilite essa comunicação. Este trabalho apresenta um dispositivo que possibilita a interação com o piso tátil para auxiliar a navegação e a orientação. Por meio de uma interface de áudio, o dispositivo proporciona ao deficiente visual as informações úteis sobre o espaço em seu entorno e as opções de navegação disponíveis. As informações pertinentes são difundidas utilizando etiquetas com tecnologia de identificação por rádio frequência, integradas a um micro controlador e uma placa de reprodução de áudio. Cada etiqueta possui um código de produto eletrônico que permite identificá-la de forma exclusiva. A etiqueta instalada em um local padronizado do piso tátil está atrelada a um arquivo de áudio com informações sobre o espaço e as rotas disponíveis. O leitor integrado a placa de desenvolvimento faz a leitura das etiquetas e envia o código eletrônico ao micro controlador, que por sua vez identifica o código e atribui a este o arquivo de áudio que será reproduzido. O dispositivo foi testado por um voluntário que encontrou todas as etiquetas posicionadas junto ao piso tátil de alerta, identificou claramente sua posição e chegou ao destino desejado sem erros de percurso. Usado como complemento da sinalização tátil, este dispositivo possibilita uma interação entre o deficiente visual e a sinalização tátil existente. Este projeto poderá contribuir diretamente para a sociedade, disponibilizando um sistema de navegação conveniente para que as pessoas com deficiência visual tenham maior autonomia
173

Estudo e desenvolvimento de um protótipo para redução da interferência de modo comum usando balanceamento dinâmico de impedância aplicado em biosensores e sensores eletroresistivos

NEGRÃO, João Francisco Ribeiro 25 October 2013 (has links)
Submitted by Cleide Dantas (cleidedantas@ufpa.br) on 2014-07-30T16:23:38Z No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Tese_EstudoDesenvolvimentoPrototipo.pdf: 4302508 bytes, checksum: 5efd9079bd10cf15d7d101c6bdbe8f64 (MD5) / Rejected by Edisangela Bastos (edisangela@ufpa.br), reason: on 2014-07-30T16:36:49Z (GMT) / Submitted by Cleide Dantas (cleidedantas@ufpa.br) on 2014-07-30T16:38:10Z No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Tese_EstudoDesenvolvimentoPrototipo.pdf: 4302508 bytes, checksum: 5efd9079bd10cf15d7d101c6bdbe8f64 (MD5) / Approved for entry into archive by Ana Rosa Silva (arosa@ufpa.br) on 2014-09-04T14:15:30Z (GMT) No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Tese_EstudoDesenvolvimentoPrototipo.pdf: 4302508 bytes, checksum: 5efd9079bd10cf15d7d101c6bdbe8f64 (MD5) / Made available in DSpace on 2014-09-04T14:15:30Z (GMT). No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Tese_EstudoDesenvolvimentoPrototipo.pdf: 4302508 bytes, checksum: 5efd9079bd10cf15d7d101c6bdbe8f64 (MD5) Previous issue date: 2013 / Programa ALBAN / FAPESPA - Fundação Amazônia de Amparo a Estudos e Pesquisas / A interferência eletromagnética causada pela linha de energia elétrica afeta negativamente os sinais de instrumentos eletrônicos, especialmente aqueles com baixos níveis de amplitude. Este tipo de interferência é conhecida como interferência de modo comum. Existem muitos métodos e arquiteturas utilizadas para minimizar a influência deste fenômeno de interferência em instrumentos eletrônicos, o mais comum dos quais é a utilização de filtros rejeita banda. Este trabalho apresenta: a análise, desenvolvimento, protótipo e teste de uma nova arquitetura de filtro com característica reconfigurável para instrumentos biomédicos e medição de dados de fluxo em fluido de alta complexidade, com objetivo de reduzir a interferência de modo comum e preservar as componentes do sinal útil na mesma faixa de frequência do ruído, utilizando a técnica de equilíbrio dinâmico de impedância. Além disso, este trabalho pode ser usado em qualquer sistema de medição que também sofra interferência na frequência da linha de alimentação (50/60 Hz, no Brasil e na França, 60 Hz nos Estados Unidos da América). Os blocos de circuitos foram modelados matematicamente e a função de transferência global do circuito fechado foi gerada. Em seguida, o projeto foi descrito e simulado na língua VHDL_AMS e também em um software de simulação eletrônica, usando blocos de componentes discretos, com e sem realimentação. Após análise teórica dos resultados da simulação, um circuito protótipo foi construído e testado usando como entrada um sinal obtido a partir de eletrodos de ECG e Eletrodos Eletroresistivos. Os resultados experimentais do circuito condizem com os da simulação: uma redução de ruído de 98,7% foi obtida em simulações utilizando um sinal sinusoidal, e uma redução de 92% foi realizada utilizando eletrodos de ECG em testes experimentais. Os mesmos testes em eletrodos Eletroresistivos, obtendo o maior valor de 80,3% de redução (durante análise de 3 casos). Em ambos os casos, o sinal útil foi preservado. O método e a sua arquitetura pode ser aplicado para atenuar as interferências que ocorrem na mesma banda de frequência das componentes do sinal útil, preservando ao mesmo tempo estes sinais. / Electromagnetic interference caused by the electric power line adversely affects the signals of electronic instruments, especially those with low amplitude levels. This type of interference is known as common-mode interference. There are many methods and architectures used to minimize the influence of this kind of interference on electronic instruments, the most common of which is the use of band-reject filters. This paper presents the analysis, development, prototype and test of a new reconfigurable filter architecture for biomedical instruments and measuring data of high complexity fluid flow, such as two phase flows, interference in the measurement circuit may affect the measured data, aiming to reduce the common-mode interference and preserve the useful signal components in the same frequency range as that of the noise, using the technique of dynamic impedance balancing. . Also, any measurement system also suffers interference in the power line frequency (50/60 Hz in Brazil and France, 60Hz in United States of America). The circuit blocks were mathematically modeled and the overall closed-loop transfer function was derived. Then the project was described and simulated in the VHDL_AMS language and also in an electronics simulation software, using discrete component blocks, with and without feedback. After theoretical analysis and simulation results, a prototype circuit was built and tested using as input a signal obtained from ECG electrodes and Resistivity Needle Probes. The results from the experimental circuit matched those from simulation: a 97.6% noise reduction was obtained in simulations using a sinusoidal signal, and an 86.66% reduction was achieved using ECG electrodes in experimental tests. In both cases, the useful signal was preserved. The method and its architecture can be applied to attenuate interferences, which occur in the same frequency band as that of the useful signal components, while preserving these signals.
174

Caracteriza??o Hematol?gica e Imunofenot?pica em Pacientes com Leucemia Linfobl?stica Aguda / Flow cytometry immunophemotyping evaluation in acute lymphoblastic leukemia: correlation to factors affecting clinic outcome

Alves, Gabriela Vasconcelos de Andrade 01 November 2012 (has links)
Made available in DSpace on 2014-12-17T14:05:22Z (GMT). No. of bitstreams: 1 GabrielaVAA_TESE.pdf: 3860712 bytes, checksum: aeadd17bd1107cbd055591f8b629d4b1 (MD5) Previous issue date: 2012-11-01 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior / A Leucemia Linfobl?stica Aguda ? uma doen?a de car?ter maligno do sistema imune e hematol?gico caracterizada pelo ac?mulo de precursores linf?ides neopl?sicos B ou T (linfoblastos) na medula ?ssea e/ou no sangue perif?rico. O diagn?stico dessas leucemias ocorre pela classifica??o do aspecto morfol?gico French-American-British (L1, L2 ou L3) associado ?s caracter?sticas do perfil imunol?gico B ou T das c?lulas malignas, tendo como base o perfil de express?o dos anticorpos monoclonais direcionados contra os ant?genos de diferencia??o celular. V?rios estudos t?m demonstrado que imunofen?tipos de c?lulas bl?sticas de casos de Leucemia Linfobl?stica Aguda nem sempre exibem caracter?sticas da diferencia??o linf?ide normal, mas sim exibem imunofen?tipos aberrantes. Assim, blastos de alguns casos de Leucemia Linfobl?stica Aguda de linhagem B podem apresentar ant?genos T ou miel?ides. Tamb?m blastos de casos de Leucemia Linfobl?stica Aguda T podem possuir determinantes de c?lulas B ou miel?ides. Objetivo: Determinar o perfil imunofenot?pico em 192 pacientes com Leucemia Linfobl?stica Aguda (B ou T) diagnosticados no Laborat?rio de Citometria de Fluxo do Hemocentro Dalton Barbosa Cunha - HEMONORTE, com base nos dados cl?nicos, laboratoriais e na imunofenotipagem pela citometria de fluxo. Metodologia: Todas as amostras de sangue perif?rico e/ou medula ?ssea foram submetidas ? imunfenotipagem por citometria de fluxo, utilizando um painel de anticorpos monoclonais espec?fico para Leucemias Agudas diretamente conjugado com at? tr?s diferentes fluorocromos por tubo: isotiocianato de fluoresce?na, do ingl?s fluorescein isothiocyanate (FITC) e/ou Phicoeritrina (PE) e/ou prote?na Piridina de clorofila, do termo em ingl?s chlorophyl de peridinin protein (PerCP). Resultados: As Leucemias Linfobl?sticas Agudas de linhagem B foram as mais predominantes, 84,38%. Observou-se uma discreta predomin?ncia dos indiv?duos do sexo masculino (56,77%). As crian?as foram as mais acometidas pela doen?a correspondendo a 58,85%. A avalia??o dos subtipos morfol?gicos identificou o L1 com 116 casos (60,42%) como o de maior predomin?ncia. Os tr?s subtipos morfol?gicos French-American-British foram detectados nas Leucemias Linfobl?sticas Agudas de linhagem B, sendo os tipos L1 e L2 mais freq?entemente observados nas Leucemia Linfobl?stica Aguda Calla+ com 72 e 25 casos, respectivamente. Os n?veis de express?o dos ant?genos T mostraram principalmente o CD3 (superf?cie e citoplasm?tico) com 8,33% e 11,17%, respectivamente. Para os ant?genos B observou-se uma maior freq??ncia de express?o para os ant?genos pan B: CD19, sCD22, cCD22 e cCD79a. Detectou-se a presen?a de fen?tipo aberrante em 66 casos. Conclus?es: O emprego sistem?tico dos anticorpos monoclonais e sua aplica??o na citometria de fluxo tem se confirmado ?til no diagn?stico diferencial das leucemias agudas, em adi??o ao diagn?stico morfol?gico
175

Intera??o de microorganismos na solubiliza??o de f?sforo e pot?ssio de rochas para produ??o de biofertilizantes

Silva, Val?ria Nogueira da 03 May 2013 (has links)
Made available in DSpace on 2014-12-17T14:05:23Z (GMT). No. of bitstreams: 1 ValeriaNS_TESE.pdf: 2082797 bytes, checksum: 3f7c49154416ffa0bea9f055c45ea17e (MD5) Previous issue date: 2013-05-03 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior / he present model of agriculture is based on intensive use of industrial inputs, due to its rapid response, but it brings harmful consequences to the environment, and it is necessary the use of modern inputs. And an alternative is the use of rock biofertilizers in agriculture, a product easy to use, with higher residual effect and does not harm the environment. The objective of study was to evaluate the inoculation and co-inoculation of different microorganisms in the solubilization of rock phosphate and potash ground microbial evaluating the best performance in the production of biofertilizers comparing with rocks pure in soil chemical properties and, verify effect of inoculation of the bacterium Paenibacillus polymyxa in the absorption of minerals dissolved in the development of cowpea (Vigna unguiculata [L.] Walp.). The first bioassay was conducted in Laboratory (UFRN) for 72 days in Petri dishes, where the rock powder was increased by 10% and sulfur co-inoculated and inoculated with bacterial suspension of Paenibacillus polymyxa grown in medium tryptone soy broth, Ralstonia solanacearum in medium Kelman, Cromobacterium violaceum in medium Luria-Bertani and Acidithiobacillus thiooxidans in medium Tuovinen and Kelly,and fungi Trichoderma humatum and Penicillium fellutanum in malt extract. Every 12 days, samples were removed in order to build up the release curve of minerals. The second bioassay was conducted in a greenhouse of the Agricultural Research Corporation of Rio Grande do Norte in experimental delineation in randomized block designs, was used 10 kg of an Yellow Argissolo Dystrophic per pot with the addition of treatments super phosphate simple (SS), potassium chloride (KCl), pure rock, biofertilizers in doses 40, 70, 100 and 200% of the recommendation for SS and KCl, and a control, or not inoculated with bacteria P. polymyxa. Were used seeds of cowpea BRS Potiguar and co-inoculated with the bacterial suspension of Bradyrhizobium japonicum and P. polymyxa. The first crop was harvested 45 days after planting, were evaluated in the dry matter (ADM), macronutrients (N, P, K, Ca, Mg) and micronutrients (Zn, Fe, Mn) in ADM. And the second at 75 days assessing levels of macro end micronutrients in plants and soil, and the maximum adsorption capacity of P in soil. The results showed synergism in co-inoculations with P. polymyxa+R. solanacearum and, P. polymyxa+C. violaceum solubilizations providing higher P and K, respectively, and better solubilization time at 36 days. The pH was lower in biofertilizers higher doses, but there was better with their addition to P at the highest dose. Significant reduction of maximum adsorption capacity of phosphorus with increasing dose of biofertilizer. For K and Ca was better with SS+KCl, and Mg to pure rock. There was an effect of fertilization on the absorption, with better results for P, K and ADM with SS+KCL, and N, Ca and Mg for biofertilizers. Generally, the P. polymyxa not influence the absorption of the elements in the plant. In treatments with the uninoculated P. polymyxa chemical fertilizer had an average significantly higher for weight and number of grains. And in the presence of the bacteria, biofertilizers and chemical fertilizers had positive values in relation to rock and control. The data show that the rocks and biofertilizers could meet the need of nutrients the plants revealed as potential for sustainable agriculture / A agricultura atual se baseia no uso intensivo de fertilizantes industrializados, por sua resposta r?pida, por?m traz consequ?ncias danosas ao ambiente, e faz-se necess?rio o uso de insumos modernos. Uma alternativa ? o uso de biofertilizantes de rochas na agricultura, um produto de f?cil manuseio, com efeito residual maior e n?o agride o meio ambiente. O objetivo do estudo foi avaliar a inocula??o e co-inocula??o de diferentes microrganismos na solubiliza??o de f?sforo e pot?ssio de rochas mo?das avaliando o melhor desempenho microbiano(s) na produ??o de biofertilizantes comparando com as rochas puras nas propriedades qu?micas do solo e, verificar o efeito da inocula??o da bact?ria Paenibacillus polymyxa na absor??o dos minerais solubilizados no desenvolvimento do feij?o caupi (Vigna unguiculata [L.] Walp.). O primeiro bioensaio foi conduzido em Laborat?rio (UFRN) por 72 dias em Placas de Petri, onde o p? de rocha era acrescido de 10% de enxofre e inoculados e co-inoculados com suspens?o bacteriana de Paenibacillus polymyxa cultivada em meio caldo triptona de soja, Ralstonia solanacearum em meio Kelman, Cromobacterium violaceum em meio Luria-Bertani e Acidithiobacillus thiooxidans em meio Tuovinen e Kelly, e os fungos Penicillium fellutanum e Tricoderma humatum em meio contendo extrato de malte. A cada 12 dias, amostras eram retiradas a fim de construir uma curva de libera??o dos minerais. O segundo bioensaio foi conduzido em casa de vegeta??o da Empresa de Pesquisa Agropecu?ria do Rio Grande do Norte, onde utilizou-se 10 kg do Argissolo Amarelo Distr?fico, por vaso, com adi??o dos tratamentos super fosfato simples (SS), cloreto de pot?ssio (KCl), rocha pura, biofertilizantes nas doses 40, 70, 100 e 200% da recomenda??o para SS e KCl, e uma testemunha, inoculados ou n?o com a bact?ria P. polymyxa. Foram utilizadas sementes da caupi BRS Potiguar e co-inoculadas com suspens?o bacteriana de Bradyrhizobium japonicum e P. polymyxa. A primeira colheita foi aos 45 dias de plantio avaliando a mat?ria seca da parte a?rea (MSPA), teores de macronutrientes (N, P, K, Ca, Mg,) e micronutrientes (Zn, Fe, Mn) na MSPA. A segunda colheita aos 75 dias avaliando teores de macro e micronutrientes na planta e no solo, e a capacidade m?xima de adsor??o de P (CMAP) no solo. Os resultados mostraram que houve sinergismo nas co-inocula??es com P. polymyxa+R. solanacearum e, P. polymyxa+C. violaceum com maiores solubiliza??es de K e P, respectivamente, e melhor tempo de solubiliza??o aos 36 dias. O pH foi mais reduzido nos biofertilizantes de maiores doses, e houve melhoras com sua adi??o para P na maior dose. Houve redu??o significativa da CMAP com o aumento da dose do biofertilizante. Houve efeito da fertiliza??o na absor??o, com melhoras para P, K e MSPA com SS+KCL, e N, Ca e Mg para biofertilizantes. De modo geral, o P. polymyxa n?o influenciou na absor??o dos elementos na planta. Para Ca e K houve melhoras com SS+KCl, e para Mg com rocha pura. O fertilizante qu?mico foi significativamente superior para peso e n?mero de gr?os, sem a presen?a do P. polymyxa. Na presen?a da bact?ria, biofertilizantes e fertilizante qu?mico apresentaram valores positivos em rela??o ? rocha e testemunha. Os dados evidenciaram que as rochas e os biofertilizantes podem suprir a necessidade de nutrientes ?s plantas revelando-se como potencial para uma agricultura sustent?vel
176

Sistema de gerenciamento de equipamentos eletromédicos

Guedert, Douglas January 2006 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Elétrica. / Made available in DSpace on 2013-07-16T03:14:53Z (GMT). No. of bitstreams: 1 235262.pdf: 1988870 bytes, checksum: 1b27b021a6265376e45d8d20ab688486 (MD5) / A Engenharia Clínica (EC) está em constante busca de alternativas que auxiliem o controle de informações nos Estabelecimentos Assistenciais de Saúde (EAS). Informações confiáveis e atualizadas sobre o parque tecnológico são indispensáveis para um adequado gerenciamento da tecnologia médico-hospitalar (gTMH). Estas informações estão relacionadas com o ciclo de vida da tecnologia, abrangendo desde as etapas de planejamento, aquisição, gerência, avaliação até o descarte e substituição dos equipamentos. Porém, os métodos utilizados na obtenção destes dados apresentam certas limitações, como por exemplo, os erros introduzidos através de preenchimentos incompletos ou incorretos, geralmente em formulários e fichas de papel. Estas falhas afetam/influenciam a confiabilidade das informações, resultando em um gerenciamento ineficiente. Aliando o conceito do gerenciamento da EC à utilização da Tecnologia da Informação (TI), pode-se agilizar estes procedimentos, acrescendo segurança e consistência aos dados extraídos. A informatização e a utilização da TI tornam-se ferramentas importantes, fazendo com que, cada vez mais, os métodos utilizados no gTMH evoluam do meio físico (papeis, formulários, cartas) para o digital. A velocidade e o acesso remoto às informações, sobre as atividades da Engenharia Clínica, potencializam o processo de tomada de decisões. Neste sentido, o presente trabalho, desenvolveu um sistema de gerenciamento de equipamentos médicos, utilizando o PDA (Personal Digital Assistant) como uma ferramenta de TI, para o armazenamento e transferência de informações, via wireless. Este sistema de gerenciamento foi testado em hospitais da cidade de Florianópolis - SC, no Brasil.
177

Sistemas centralizados de gases e vácuo medicinais

Santos, Rubia Alves da Luz January 2002 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Elétrica. / Made available in DSpace on 2012-10-20T09:26:00Z (GMT). No. of bitstreams: 0Bitstream added on 2014-09-26T02:16:38Z : No. of bitstreams: 1 186106.pdf: 7872819 bytes, checksum: 4998eedca46af9a181601ff85cb431a7 (MD5) / Este trabalho aborda os sistemas centralizados de oxigênio, óxido nitroso, ar e vácuo medicinais, os quais são compostos pela central de suprimento, rede de distribuição e postos de utilização. Também retrata como a qualidade do gerenciamento destes sistemas influencia outros elementos da tecnologia médico-hospitalar, tais como os equipamentos que utilizam os gases e vácuo, o atendimento ao paciente, a efetividade e a relação custo-benefício. São discutidos aspectos relacionados ao projeto, execução e manutenção, após uma descrição da principais características dos sistemas centralizados e dos equipamentos que os compõem, bem como das recomendações normativas e regulamentações nacionais vigentes. Com base nas informações teóricas reunidas, um estudo de caso foi realizado através da coleta de dados e análise em centrais de suprimento e redes de distribuição de quatro hospitais públicos e quatro privados localizados no estado de Santa Catarina. Para quantificar a severidade e a ocorrência dos possíveis problemas decorrentes das desconformidades pesquisadas, propõe-se uma metodologia baseada na técnica de Análise de Efeitos, Modos de Falha e Criticalidade (FMECA). A análise dos dados da pesquisa mostra que algumas desconformidades encontradas independem do tipo de hospital, como exemplo, dos hospitais públicos e privados visitados, 100% não possuem alarmes operacionais indicando quando o suprimento secundário ou reserva está em operação e o acionamento é realizado de forma manual. O propósito deste trabalho é propor uma metodologia aplicável por estruturas de engenharia clínica, ou a assessoria destas estruturas aos profissionais responsáveis por estes sistemas, com o objetivo de melhorar a situação atual.
178

Plataforma de força para aplicações biomédicas

Freitas, Ricardo Luiz Barros de [UNESP] 30 May 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:22:31Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-05-30Bitstream added on 2014-06-13T20:47:51Z : No. of bitstreams: 1 freitas_rlb_me_ilha.pdf: 2701208 bytes, checksum: 5ab311e644d8a3837fea549fd3136b7e (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Neste trabalho, descreve-se um sistema eletrônico informatizado implementado com o objetivo de medir a distribuição do peso corporal na região plantar de pacientes, visando relacioná-la diretamente à tipologia e deformidades dos pés e associando-a, indiretamente, a eventuais deformidades dos membros inferiores, coluna vertebral, algias músculoesqueléticas e instabilidades da postura humana. O sistema é constituído por células de carga com extensômetros, montadas em uma base metálica, circuito de condicionamento de sinais, circuito de interfaceamento e um display de cristal líquido. Foi construída uma plataforma piloto com 4 células de carga, mas o projeto do sistema prevê a construção de duas plataformas com 45 células de cargas, cada uma. As células de carga apresentaram resposta linear, precisão superior a 2%, resolução inferior a 0,5 N e histerese desprezível. São apresentados os resultados de medições, efetuadas com o sistema, para medir a distribuição de forças nas quatro células de carga, quando se aplicou sobre elas um peso conhecido. As informações foram apresentadas em um display de cristal líquido e posteriormente serão apresentadas na tela de um computador, por meio de um programa desenvolvido em Delphi, facilitando a visualização para especialistas da área, principalmente médicos, fisioterapeutas e terapeutas ocupacionais. Com o equipamento proposto será possível investigar, clinicamente, patologias estudadas pela Podologia, Posturologia e Podoposturologia, viabilizando, com as informações captadas pelo sistema, metodologias mais adequadas de tratamentos. / In this work we describe an electrical system implemented with the purpose of measuring the distribution of body weight in plantar region of patients, aiming to relate it directly to the typology and deformities of the feet and involving it, indirectly, to any deformities of the lower limbs, skeletal spine, muscle-skeletal pains and human posture instability. The system consists of load cells with strain gages within a metal base, signal conditioning circuit, interfacing circuit, and a liquid crystal display. A prototype platform with 4 load cells was built, but the system will have two platforms with 45 loads of cells, each one. The load cells presented linear response, precision better than 2%, resolution less than 0.5 N, and low hysteresis. We show the results of the force distribution when a know weight is applied over the four load cells. The informations have been presented in a liquid crystal display, but later they will be presented in the screen of a computer, facilitating the visualization for specialists, mainly doctors, physiotherapists and occupational therapists. With the proposed equipment it will be possible to investigate, clinically, pathologies studied by Podology, Posturology and Podoposturology making feasible, with the information obtained with the system, more appropriate methodologies of treatment.
179

Avaliação da dose ocupacional em exame de uretrocistografia com equipamento de fluoroscopia / Occupational dose evaluation in urethrocystography exam with fluoroscopy equipment

Baroni, Keity Priscile 17 September 2015 (has links)
Ao longo da evolução dos equipamentos e exames radiológicos, a exposição dos pacientes e trabalhadores envolvidos tem aumentado em grande proporção. Esta exposição não deve ser subestimada, uma vez que acumulada ao longo dos anos pode trazer riscos para a saúde do indivíduo exposto. O objetivo deste trabalho foi verificar a taxa de exposição de trabalhadores à radiação ionizante. Foram realizadas simulações do exame de uretrocistografia utilizando-se de uma câmara de ionização, para verificar a taxa de exposição, colocando-se dosímetros termoluminescentes de em cada espalhador verificando a dose efetiva em locais específicos do corpo do indivíduo ocupacionalmente exposto durante o procedimento. A posição da mesa de exames foi variada durante a exposição para avaliar se esta tem influencia na dose recebida pelos trabalhadores. Os resultados revelaram uma grande diminuição da dose quando a posição da mesa está na horizontal. O aumento da distância dos espalhadores ao paciente teve uma diminuição significativa da taxa de exposição. A maioria dos resultados se apresentou abaixo dos limites preconizados, porém o dosímetro colocado na altura do tórax do espalhador posicionado mais próximo ao paciente excedeu este limite. Portanto, os procedimentos de trabalho devem ser sempre observados com o intuito de manter os limites dentro de um nível de segurança. / Throughout the evolution of radiological equipment and tests, the exposure of patients and workers involved has increased to a great extent. This exhibition should not be underestimated, since accumulated over the years can bring risks to the health of the exposed individual. The objective of this study was to determine the rate of exposure of workers in an X-ray room. Examining urethrocystography simulations were performed using an ionization chamber, to verify the exposure rate, and thermoluminescent dosimeters in each cap to check the effective dose in specific locations of the individual's body occupationally exposed in the examen. The position of the examination table was varied during exposure to assess whether this has influence on the dose received by the workers. The results showed a large decrease in dose when the table position is horizontally. Increased distance spreaders of the patient had a significant decrease in exposure rate. The majority of results presented below recommended limits, but the dosimeter positioned at the height of the thorax on the spreader lens closest to the patient exceeded this limit. Therefore, work procedures should always be observed in order to keep within the limits of a security level.
180

Caracterização e calibração de um sensor a fibra ótica baseado em redes de Bragg para análise biomecânica in vivo / Characterization and calibration of a fiber optical sensor based on Bragg gratings for biomechanical analysis in vivo

Kalinowski, Alessandra 26 April 2017 (has links)
CAPES / O presente trabalho estuda o comportamento de um biosensor que utiliza redes de Bragg em fibra ótica capaz de mensurar deformações em tecido ósseo. O objetivo é calibrar e caracterizar o sensor com seu encapsulamento para que este possa futuramente ser implantado em um animal vivo e assim permita aprimorar estudos a respeito do comportamento ósseo em sua microestrutura. Para o desenvolvimento deste estudo e preciso conhecer o comportamento ósseo como um todo, a biomecânica do local específico onde pretende-se implantar o sensor, o funcionamento do sensor, bem como o comportamento de seu encapsulamento; portanto, todos esses aspectos são estudados. Para caracterização e calibração do sensor encapsulado foi realizado teste de tração em um programa de computador (simulação numérica) e arranjo experimental de calibração (teste prático), para que seja possível sua aplicação final desejada. Os testes realizados são descritos neste trabalho. Os resultados obtidos demonstram que o transdutor e o encapsulamento utilizado são adequados para captar deforma coes inferiores a 0,1 N, apresentam resposta linear, com um coeficiente de correlação da média dos 5 sensores testados em 0,999, incerteza expandida de 0,07 N e coeficiente de carga de 77 pm/N; boa repetibilidade, e componentes biocompatíveis, sendo assim, o sensor e adequado para aplicações in vivo. Através dos testes também foi possível determinar o melhor local e maneira para sua implementação em uma aplicação específica, que e a análise de deformação óssea em uma superfície externa de mandíbula bovina durante movimentos mastigatórios de diferentes alimentos. / The present work studies behavior of a biosensor that uses Bragg gratings in optical fibers, capable to measuring deformations in bone tissue. The aim is to characterize and calibrate the sensor with its encapsulation so that it can be implanted in a living animal in the future and thus allow to improve studies about bone behavior in its microstructure. For the development of this study it is necessary to know the bone behavior as a whole, the biomechanics of the specific area where the sensor will be implanted, the sensor operation, as well as the behavior of its encapsulation; herefore, all these aspects are studied. For the characterization and calibration of the encapsulated sensor, a software traction test (numerical simulation) and an experimental calibration arrangement (practical test) were carried out, so that its desired final application could be possible. The tests performed are described in this work. The results show that the transducer and the encapsulation used are adequate to capture deformations lower than 0.1 N, presented a linear response, with a correlation coefficient of the average of 5 sensors at 0.999, expanded uncertainty of 0.07 N and slope 77 pm/N; good repeatability, and biocompatible components. The sensor is suitable for in vivo applications. Through the tests it was also possible to determine the best place and way for its implementation in a specific application, that is the analysis of bone deformation on an external surface of bovine mandible during chewing movements of different foods.

Page generated in 0.0384 seconds