• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 346
  • 4
  • Tagged with
  • 350
  • 350
  • 199
  • 195
  • 138
  • 123
  • 118
  • 94
  • 89
  • 67
  • 54
  • 52
  • 50
  • 47
  • 47
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
141

Estudo de custo para implementar centros de engenharia clínica em unidades hospitalares /

Barbosa, Andréa Teresa Riccio January 1999 (has links)
Dissertação (Mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. / Made available in DSpace on 2012-10-18T21:47:25Z (GMT). No. of bitstreams: 0Bitstream added on 2016-01-09T01:55:59Z : No. of bitstreams: 1 147353.pdf: 5888471 bytes, checksum: b741ab7a635fa0154527383a9ced305b (MD5)
142

Sistema especialista para predição de complicações cardiovasculares integrado a um sistema de controle de pacientes portadores de diabetes mellitus /

Montello, Marlise Vidal January 1999 (has links)
Dissertação (Mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. / Made available in DSpace on 2012-10-19T00:13:56Z (GMT). No. of bitstreams: 0Bitstream added on 2016-01-09T03:10:33Z : No. of bitstreams: 1 137927.pdf: 21936152 bytes, checksum: bfc2c1b2d0963b70638894ffff723618 (MD5)
143

Procedimentos de aquisição de equipamentos médico-assistenciais : uma ferramenta computadorizada de apoio /

Vergara Galeano, Júlio César January 1999 (has links)
Dissertação (Mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. / Made available in DSpace on 2012-10-19T01:22:24Z (GMT). No. of bitstreams: 0Bitstream added on 2016-01-09T02:44:12Z : No. of bitstreams: 1 138979.pdf: 30265646 bytes, checksum: 20db38d42e4323221f1f99e9aaab92a3 (MD5)
144

Estudo de funcionalidade e segurança de aparelhos que utilizam ondas de choque para terapia - litotripsia

Kolzer, José Fabio January 2001 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Elétrica. / Made available in DSpace on 2012-10-19T10:08:36Z (GMT). No. of bitstreams: 0Bitstream added on 2014-09-25T21:39:35Z : No. of bitstreams: 1 179678.pdf: 12044321 bytes, checksum: 0e58e4c9736dbbc2ec3726821956ac5d (MD5) / A Litotripsia Extracorpórea por Ondas de Choque (LEOC) é uma terapia que apresenta menores riscos para o paciente quando comparada a outras terapias utilizadas para tratar cálculos urinários. Porém, a tecnologia utilizada para a realização da LEOC envolve riscos que às vezes não são totalmente conhecidos pelos operadores destes equipamentos. Além disso, no Brasil, atualmente não existem normas relativas a ensaios de segurança e funcionalidade para este tipo equipamentos. O presente estudo apresenta os fatores tanto físicos quanto clínicos que influenciam na eficácia e segurança da LEOC. São também indicados os ensaios de funcionalidade a serem realizados nestes equipamentos e os instrumentos de medição para fazê-los.
145

Instrumentação para a monitoração das alterações eletrocardiográficas decorrentes da hipoglicemia

Garcia, Euler de Vilhena January 2001 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Elétrica. / Made available in DSpace on 2012-10-19T11:24:15Z (GMT). No. of bitstreams: 0Bitstream added on 2014-09-25T20:39:52Z : No. of bitstreams: 1 182250.pdf: 23067680 bytes, checksum: b0d5c927e0e59d4689744650122749b4 (MD5) / A busca da melhoria na qualidade de vida sempre é uma constante no tratamento de doenças crônicas, em especial o diabetes mellitus. Um controle rígido da taxa de glicose sangüínea por si só evitaria um grande número de complicações tardias. Esta é, entretanto, uma condição de risco pois favorece o surgimento de hipoglicemia, situação que pode resultar em morte caso não revertida a tempo. Estudos preliminares demonstram ser o eletrocardiograma uma abordagem promissora para a detecção indireta de hipoglicemia. Em um quadro hipoglicêmico foram reportadas: alterações na freqüência cardíaca e no intervalo ST; aumento do intervalo QT, com casos de fusão das ondas T e U; diminuição do valor de pico da onda T. Esta dissertação trata do desenvolvimento da instrumentação necessária para o monitoramento destas alterações eletrocardiográficas. O protótipo, alimentado por uma bateria de 9V, obtém automaticamente o ECG sendo controlado por um computador tipo palmtop. O processamento do ECG analisa não só parâmetros de uso consagrado (como os intervalos RR, QT e os valores de pico das ondas R e T) mas também a razão R/T e o Fator de Assimetria - variável proposta neste trabalho, criada para a medição quantitativa de alterações morfológicas como o achatamento da onda T e o grau de fusão entre as ondas T e U. A avaliação do protótipo e da metodologia demonstra que os resultados dessa dissertação, após pequenos melhoramentos, podem de fato ser utilizados como a etapa base do desenvolvimento de um detector não-invasivo de hipoglicemia totalmente baseado no ECG
146

Contribuição à automatização da detecção e análise de eventos epileptiformes em eletroencefalograma

Argoud, Fernanda Isabel Marques January 2001 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Elétrica / Made available in DSpace on 2012-10-19T11:42:53Z (GMT). No. of bitstreams: 0Bitstream added on 2014-09-25T21:33:44Z : No. of bitstreams: 1 179949.pdf: 111603845 bytes, checksum: b886141e491c6a4bcc486450433832c4 (MD5) / O presente trabalho visa propor uma arquitetura de sistema para processamento de sinais eletroencefalográficos (EEG), que utilize métodos e ferramentas de análise não-linear, tais como Transformada Wavelet e Redes Neurais Artificiais (RNAs), com o intuito de fazer-se a detecção e o reconhecimento de descargas epileptiformes do tipo Espícula-Onda (spikes), possivelmente presentes no sinal. O sistema baseado em computador proposto (SIDAPE) transforma os sinais de EEG através de Transformada Wavelet Rápida (FWT) e a representação resultante serve de entrada para um grupo de Redes Neurais Artificiais, as quais fazem a detecção e a classificação das Descargas Epileptiformes. Para o primeiro estágio do sistema desenvolveu-se uma metodologia no sentido de maximizar o aproveitamento da FWT na identificação das descargas epileptiformes do EEG. Assim, determinou-se que, em um conjunto de 47 wavelet kernel conhecidas, a função wavelet coiflet 1 é a que oferece a maior correlação morfológica com as espículas e, por conseqüência, maior grau de compactação na decomposição. Os resultados foram avaliados para a análise de janelas de 15s e o SIDAPE foi capaz de detectar espículas com 98,4% de especificidade, o que indica segurança quanto a detecções positivas.O sistema também apresentou 96,2% de acertos na classificação.
147

Análise dos Sinais dos Ruídos Articulares das Patologias Discais da Articulação Temporomandibular

Silva, Álvaro Múcio Leite da [UNESP] 13 December 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:34:57Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-12-13Bitstream added on 2014-06-13T20:05:57Z : No. of bitstreams: 1 000732454.pdf: 4504195 bytes, checksum: c662b6284869940dac7e921c17f20ab1 (MD5) / Esse trabalho teve como objetivos desenvolver um método diagnóstico inédito opcional aos já existentes no tratamento das DTMs, gerar um banco de dados referentes à patologia em estudo e propor um procedimento de análise do sistema côndilo-disco e fossa da ATM, visando identificar e classificar individualmente tal sistema por meio de sinais elétricos provenientes dos ruídos articulares, auxiliar nos procedimentos clínicos, agregar dados para o prontuário do paciente e oferecer uma fonte de consulta para futuras pesquisas. Foi utilizado um sistema devidamente calibrado para a coleta de dados composto por um conjunto estetoscópio/microfone e equipamentos para processamento e armazenamento dos dados; adicionalmente, foram obtidas imagens por meio de Ressonância Magnética Nuclear das ATMs esquerda e direita de cada voluntário para uma confirmação do comportamento da articulação em análise e suas patologias. Para os cálculos dos parâmetros no domínio do tempo e da frequência foram utilizados os aplicativos Microsoft Excel 2010 e Origin Pro, versão 8.5.1 SR2. Pelos sinais acústicos, evidenciaram-se os instantes de início e término de cada ciclo de abertura e fechamento com os seus respectivos Níveis de Pressão Sonora. A técnica desenvolvida neste trabalho de caráter não invasivo e de relativa praticidade pode ser aplicável sem grandes dificuldades por profissionais da área da saúde / This work aims to develop a diagnostic option to the existing treatment of TMD, generate a database concerning the pathology under study and propose a procedure for analyzing the system disc and condyle - fossa TMJ , to identify and classify such a system by means of electrical signals from the joint noises , assist in clinical procedures , aggregate data for the patient's records and provide a source of information for future researches . A properly calibrated system for data collection comprising a set with stethoscope / microphone and equipment for processing and storage of data was utilized; in addition, images were obtained through left and right NMR of ATMs of each volunteer to confirm the behavior of the articulation analysis and its pathologies. For the calculations of the parameters in the time domain and frequency applications, Microsoft Excel 2010 and Origin Pro version 8.5.1 SR2 were utilized. By means of acoustic signals, the moments of beginning and end of each cycle of opening and closing with their respective NPS became evident. The technique developed in this study of noninvasive nature and relative practicality can be applied with no major difficulties by health professionals
148

Aplicativo Android para aquisição de dados de um baropodômetro via Bluetooth para apoio na análise de escoliose

Nobukuni, Maria Inez [UNESP] 05 December 2014 (has links) (PDF)
Made available in DSpace on 2015-08-20T17:09:34Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-12-05. Added 1 bitstream(s) on 2015-08-20T17:26:51Z : No. of bitstreams: 1 000836453.pdf: 1866743 bytes, checksum: 1285cde6dfcb22e2cad35f26f48ec2cb (MD5) / Foi implementado um aplicativo para o sistema operacional Android, visando realizar a aquisição de dados de um baropodômetro via Bluetooth para apoio na análise de escoliose por profissionais da área da saúde. O aplicativo foi desenvolvido com a linguagem de programação orientada a objetos Java, no ambiente de desenvolvimento Eclipse. Esse aplicativo possibilita armazenar e visualizar informações de voluntários, como dados pessoais e medidas de força na região plantar de pacientes. Para a transmissão dos dados do baropodômetro foi desenvolvida uma instrumentação constituída por uma plataforma Arduino, um dispositivo PSoC, um módulo Bluetooth, um amplificador de instrumentação, um multiplexador, reguladores de tensão e potenciômetros. Utilizando o sistema implementado foi possível observar nitidamente diferenças na distribuição da descarga de peso na região plantar de voluntários hígidos e de voluntários com escoliose. Os resultados obtidos evidenciaram que os pacientes com escoliose descarregam de forma mais desigual os pesos nos pés direito e esquerdo que os pacientes hígidos. A maior diferença no percentual de descarga de peso entre os pacientes com escoliose e os hígidos ocorreu no médio pé, que nos pacientes com escoliose é menos da metade da que ocorre nos pacientes hígidos / An application for the Android operating system that performs data acquisition of a baropodometer via Bluetooth to support the analysis of scoliosis by health care professionals was implemented. The application was developed with Java object oriented programming language in the Eclipse development environment. This application allows storing and displaying informations of volunteers, such as personal data and mensurements of force in the plantar region of patients. For the transmission of the barapodometer data, an instrumentation built with an Arduino platform, a PSoC device, a Bluetooth module, an instrumentation amplifier, a multiplexer, voltage regulators and pots was used. Using the implemented system, we can clearly see differences in the distribution of weightbearing in the plantar region of healthy volunteers and volunteers with scoliosis. The results showed that patients with scoliosis unload more unequally weights on the right and left feet that healthy patients. The biggest difference in the percentage of weightbearing in patients with scoliosis and healthy occurred in the midfoot. In patients with scoliosis, in this plantar region, the percentage of weightbearing is less than half of that in healthy patients
149

Desenvolvimento de um aplicativo Android e de uma interface bluetooth para um dinamômetro biomédico

Paulo, Jean Vitor de [UNESP] 05 June 2014 (has links) (PDF)
Made available in DSpace on 2014-12-02T11:16:55Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-06-05Bitstream added on 2014-12-02T11:20:54Z : No. of bitstreams: 1 000800362.pdf: 2368706 bytes, checksum: 3177acc4808af9d8f2095cbc87138528 (MD5) / Neste trabalho, implementou-se um aplicativo para o sistema operacional Android para recebimento das informações transmitidas de um dinamômetro biomédico eletrônico por meio de uma interface bluetooth. Com esta finalidade, uma instrumentação contendo um microcontrolador PSoC e um adaptador Zuchi ZT-05 foi utilizada para transmitir os dados. O software desenvolvido é provido de diversos módulos de cadastros, configurações e visualização de informações e foi capaz de realizar o correto manuseio dos dados. Para avaliar o funcionamento do sistema, realizou-se a medição da força de preensão de 20 voluntários, sendo 10 hígidos e 10 com patologias nas mãos. O software desenvolvido gerenciou adequadamente os exames de todos os voluntários. Utilizando o dinamômetro implementado, mediu-se pela primeira vez, pelo que é de nosso conhecimento, a força exercida pelos músculos lumbricais de um paciente. Pode-se constatar que as análises das forças de preensão foram melhor e mais facilmente realizadas graças aos recursos que o aplicativo fornece / In this work an application for the Android operating system was implemented for receiving data from a biomedical electronic dynamometer sent via a bluetooth interface. For this purpose, an instrumentation having the PSoC microcontroller and a Zuchi ZT-05 adapter was used to transmit the data. The developed software is provided with many different modules, like registrations, settings and information display and was able to make a proper data handling. To evaluate the system's operation, the grip strength of 20 volunteers, 10 healthy and 10 with pathologies hands, was measured. The developed software properly managed all the volunteers exams. Using the implemented dynamometer, for the first time, to the best of our knowledge, the force exerted by the lumbrical muscles of a patient was measured. It can be verified that the analysis of the grip strength were better and more easily achieved with the resources that the software provides
150

Dinamômetro biomédico para avaliação funcional das mãos

Santos, Elcio Alteris dos [UNESP] 20 February 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:22:31Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-02-20Bitstream added on 2014-06-13T18:07:11Z : No. of bitstreams: 1 santos_ea_me_ilha.pdf: 1369014 bytes, checksum: 7ea566c05320b595e08fe89ae2170203 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O teste de força de aperto das mãos tem como finalidade detectar eventuais patologias nos membros superiores e avaliar a força exercida pelas mãos de pacientes. Neste trabalho é descrito o desenvolvimento de um dinamômetro biomédico projetado para efetuar a avaliação funcional das mãos, através da utilização de moldes específicos. O equipamento é constituído basicamente por sensores com extensômetros metálicos, um circuito de condicionamento de sinais, um circuito de interfaceamento e por um display digital. O circuito de condicionamento de sinais foi implementado com um amplificador de instrumentação, um amplificador com ganho programável e por um filtro passa-baixas. O principal componente do circuito de interfaceamento é o microcontrolador ATMEGA8. O equipamento é robusto, apresenta resposta linear na faixa de 0 a 500 N, precisão de 0,54%, resolução de 0,70 N e histerese desprezível. O valor da força pode ser lida em um display e também na tela de um computador. Pode ser útil em Engenharia de Reabilitação, Fisioterapia e Terapia Ocupacional / In this work we describe the development of a biomedical dynamometer. It was designed with the goal of performing the functional evaluation of hands with specific shapes. The equipment is constituted by force sensors, a signal conditioning circuit, an interface circuit and a digital display. Metallic strain gages were used as sensors. The signal conditioning circuit is constituted by an instrumentation amplifier, a programmable gain amplifier and a low-pass filter. The main component of the interface circuit is an ATMEGA8 microcontroller. The instrument can measure forces with resolution of 0.70 N and precision of 0.54% in the range of 0 to 500 N. It is rugged, presents linear response and very small hysteresis. The value of the force can be read in a display and in a computer screen. The device can be useful in Rehabilitation Engineering, Physiotherapy and Ocupational Therapy

Page generated in 0.0323 seconds