31 |
Sistema RFID complementar de piso tátil para localização de deficientes visuais em ambientes fechadosAraujo, Renato Pereira de 02 March 2015 (has links)
Made available in DSpace on 2016-04-27T17:05:59Z (GMT). No. of bitstreams: 1
Renato Pereira de Araujo.pdf: 1711666 bytes, checksum: b5ad19e844d9c137553ad64b03b603c7 (MD5)
Previous issue date: 2015-03-02 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / For the visually impaired, identify which path to follow to reach the desired destination without assistance from healthy people is a challenge. To move in an unknown environment is required to interact with the mechanisms of information. However the visually impaired do not yet have a navigation system in indoor environments with real-time response that allows this this communication. This paper presents a device that allows interaction with the tactile floor to aid navigation and orientation. Through an audio interface, the device provides the visually impaired relevant information on the space around it and the navigation options available. The relevant information is disseminated using labels with radio frequency identification technology, integrated into a microcontroller and an audio playback card. Each label has an electronic product code that allows to identify it uniquely. The label installed in a standard place of tactile floor is linked to an audio file with information about the space and the available routes. The reader integrated development board reads the labels and sends the electronic code to the microcontroller, which in turn identifies the code and assigns this audio file to be played. The device was tested by a volunteer who found all labels positioned on the floor tactile alert, clearly identified its position and reached the desired destination without route errors. Used as a complement to tactile signage, this device provides an interaction between the visually impaired and the existing tactile signage. This project will directly contribute to society, providing a convenient navigation system for people with visual disabilities have greater autonomy / Para os deficientes visuais, identificar qual caminho deve ser seguido para chegar ao destino desejado, sem auxílio de pessoas hígidas, é um desafio. Para se deslocar em um ambiente desconhecido é necessária a interação com os mecanismos de informação. Entretanto os deficientes visuais ainda não contam com um sistema de navegação em ambientes internos com resposta em tempo real que possibilite essa comunicação. Este trabalho apresenta um dispositivo que possibilita a interação com o piso tátil para auxiliar a navegação e a orientação. Por meio de uma interface de áudio, o dispositivo proporciona ao deficiente visual as informações úteis sobre o espaço em seu entorno e as opções de navegação disponíveis. As informações pertinentes são difundidas utilizando etiquetas com tecnologia de identificação por rádio frequência, integradas a um micro controlador e uma placa de reprodução de áudio. Cada etiqueta possui um código de produto eletrônico que permite identificá-la de forma exclusiva. A etiqueta instalada em um local padronizado do piso tátil está atrelada a um arquivo de áudio com informações sobre o espaço e as rotas disponíveis. O leitor integrado a placa de desenvolvimento faz a leitura das etiquetas e envia o código eletrônico ao micro controlador, que por sua vez identifica o código e atribui a este o arquivo de áudio que será reproduzido. O dispositivo foi testado por um voluntário que encontrou todas as etiquetas posicionadas junto ao piso tátil de alerta, identificou claramente sua posição e chegou ao destino desejado sem erros de percurso. Usado como complemento da sinalização tátil, este dispositivo possibilita uma interação entre o deficiente visual e a sinalização tátil existente. Este projeto poderá contribuir diretamente para a sociedade, disponibilizando um sistema de navegação conveniente para que as pessoas com deficiência visual tenham maior autonomia
|
32 |
Estudo e desenvolvimento de um protótipo para redução da interferência de modo comum usando balanceamento dinâmico de impedância aplicado em biosensores e sensores eletroresistivosNEGRÃO, João Francisco Ribeiro 25 October 2013 (has links)
Submitted by Cleide Dantas (cleidedantas@ufpa.br) on 2014-07-30T16:23:38Z
No. of bitstreams: 2
license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5)
Tese_EstudoDesenvolvimentoPrototipo.pdf: 4302508 bytes, checksum: 5efd9079bd10cf15d7d101c6bdbe8f64 (MD5) / Rejected by Edisangela Bastos (edisangela@ufpa.br), reason: on 2014-07-30T16:36:49Z (GMT) / Submitted by Cleide Dantas (cleidedantas@ufpa.br) on 2014-07-30T16:38:10Z
No. of bitstreams: 2
license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5)
Tese_EstudoDesenvolvimentoPrototipo.pdf: 4302508 bytes, checksum: 5efd9079bd10cf15d7d101c6bdbe8f64 (MD5) / Approved for entry into archive by Ana Rosa Silva (arosa@ufpa.br) on 2014-09-04T14:15:30Z (GMT) No. of bitstreams: 2
license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5)
Tese_EstudoDesenvolvimentoPrototipo.pdf: 4302508 bytes, checksum: 5efd9079bd10cf15d7d101c6bdbe8f64 (MD5) / Made available in DSpace on 2014-09-04T14:15:30Z (GMT). No. of bitstreams: 2
license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5)
Tese_EstudoDesenvolvimentoPrototipo.pdf: 4302508 bytes, checksum: 5efd9079bd10cf15d7d101c6bdbe8f64 (MD5)
Previous issue date: 2013 / Programa ALBAN / FAPESPA - Fundação Amazônia de Amparo a Estudos e Pesquisas / A interferência eletromagnética causada pela linha de energia elétrica afeta negativamente os sinais de instrumentos eletrônicos, especialmente aqueles com baixos níveis de amplitude. Este tipo de interferência é conhecida como interferência de modo comum. Existem muitos métodos e arquiteturas utilizadas para minimizar a influência deste fenômeno de interferência em instrumentos eletrônicos, o mais comum dos quais é a utilização de filtros rejeita banda. Este trabalho apresenta: a análise, desenvolvimento, protótipo e teste de uma nova arquitetura de filtro com característica reconfigurável para instrumentos biomédicos e medição de dados de fluxo em fluido de alta complexidade, com objetivo de reduzir a interferência de modo comum e preservar as componentes do sinal útil na mesma faixa de frequência do ruído, utilizando a técnica de equilíbrio dinâmico de impedância. Além disso, este trabalho pode ser usado em qualquer sistema de medição que também sofra interferência na frequência da linha de alimentação (50/60 Hz, no Brasil e na França, 60 Hz nos Estados Unidos da América). Os blocos de circuitos foram modelados matematicamente e a função de transferência global do circuito fechado foi gerada. Em seguida, o projeto foi descrito e simulado na língua VHDL_AMS e também em um software de simulação eletrônica, usando blocos de componentes discretos, com e sem realimentação. Após análise teórica dos resultados da simulação, um circuito protótipo foi construído e testado usando como entrada um sinal obtido a partir de eletrodos de ECG e Eletrodos Eletroresistivos. Os resultados experimentais do circuito condizem com os da simulação: uma redução de ruído de 98,7% foi obtida em simulações utilizando um sinal sinusoidal, e uma redução de 92% foi realizada utilizando eletrodos de ECG em testes experimentais. Os mesmos testes em eletrodos Eletroresistivos, obtendo o maior valor de 80,3% de redução (durante análise de 3 casos). Em ambos os casos, o sinal útil foi preservado. O método e a sua arquitetura pode ser aplicado para atenuar as interferências que ocorrem na mesma banda de frequência das componentes do sinal útil, preservando ao mesmo tempo estes sinais. / Electromagnetic interference caused by the electric power line adversely affects the signals of electronic instruments, especially those with low amplitude levels. This type of interference is known as common-mode interference. There are many methods and architectures used to minimize the influence of this kind of interference on electronic instruments, the most common of which is the use of band-reject filters. This paper presents the analysis, development, prototype and test of a new reconfigurable filter architecture for biomedical instruments and measuring data of high complexity fluid flow, such as two phase flows, interference in the measurement circuit may affect the measured data, aiming to reduce the common-mode interference and preserve the useful signal components in the same frequency range as that of the noise, using the technique of dynamic impedance balancing. . Also, any measurement system also suffers interference in the power line frequency (50/60 Hz in Brazil and France, 60Hz in United States of America). The circuit blocks were mathematically modeled and the overall closed-loop transfer function was derived. Then the project was described and simulated in the VHDL_AMS language and also in an electronics simulation software, using discrete component blocks, with and without feedback. After theoretical analysis and simulation results, a prototype circuit was built and tested using as input a signal obtained from ECG electrodes and Resistivity Needle Probes. The results from the experimental circuit matched those from simulation: a 97.6% noise reduction was obtained in simulations using a sinusoidal signal, and an 86.66% reduction was achieved using ECG electrodes in experimental tests. In both cases, the useful signal was preserved. The method and its architecture can be applied to attenuate interferences, which occur in the same frequency band as that of the useful signal components, while preserving these signals.
|
33 |
Caracteriza??o Hematol?gica e Imunofenot?pica em Pacientes com Leucemia Linfobl?stica Aguda / Flow cytometry immunophemotyping evaluation in acute lymphoblastic leukemia: correlation to factors affecting clinic outcomeAlves, Gabriela Vasconcelos de Andrade 01 November 2012 (has links)
Made available in DSpace on 2014-12-17T14:05:22Z (GMT). No. of bitstreams: 1
GabrielaVAA_TESE.pdf: 3860712 bytes, checksum: aeadd17bd1107cbd055591f8b629d4b1 (MD5)
Previous issue date: 2012-11-01 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior / A Leucemia Linfobl?stica Aguda ? uma doen?a de car?ter maligno do sistema imune e hematol?gico caracterizada pelo ac?mulo de precursores linf?ides neopl?sicos B ou T (linfoblastos) na medula ?ssea e/ou no sangue perif?rico. O diagn?stico dessas leucemias ocorre pela classifica??o do aspecto morfol?gico French-American-British (L1, L2 ou L3) associado ?s caracter?sticas do perfil imunol?gico B ou T das c?lulas malignas, tendo como base o perfil de express?o dos anticorpos monoclonais direcionados contra os ant?genos de diferencia??o celular. V?rios estudos t?m demonstrado que imunofen?tipos de c?lulas bl?sticas de casos de Leucemia Linfobl?stica Aguda nem sempre exibem caracter?sticas da diferencia??o linf?ide normal, mas sim exibem imunofen?tipos aberrantes. Assim, blastos de alguns casos de Leucemia Linfobl?stica Aguda de linhagem B podem apresentar ant?genos T ou miel?ides. Tamb?m blastos de casos de Leucemia Linfobl?stica Aguda T podem possuir determinantes de c?lulas B ou miel?ides. Objetivo: Determinar o perfil imunofenot?pico em 192 pacientes com Leucemia Linfobl?stica Aguda (B ou T) diagnosticados no Laborat?rio de Citometria de Fluxo do Hemocentro Dalton Barbosa Cunha - HEMONORTE, com base nos dados cl?nicos, laboratoriais e na imunofenotipagem pela citometria de fluxo. Metodologia: Todas as amostras de sangue perif?rico e/ou medula ?ssea foram submetidas ? imunfenotipagem por citometria de fluxo, utilizando um painel de anticorpos monoclonais espec?fico para Leucemias Agudas diretamente conjugado com at? tr?s diferentes fluorocromos por tubo: isotiocianato de fluoresce?na, do ingl?s fluorescein isothiocyanate (FITC) e/ou Phicoeritrina (PE) e/ou prote?na Piridina de clorofila, do termo em ingl?s chlorophyl de peridinin protein (PerCP). Resultados: As Leucemias Linfobl?sticas Agudas de linhagem B foram as mais predominantes, 84,38%. Observou-se uma discreta predomin?ncia dos indiv?duos do sexo masculino (56,77%). As crian?as foram as mais acometidas pela doen?a correspondendo a 58,85%. A avalia??o dos subtipos morfol?gicos identificou o L1 com 116 casos (60,42%) como o de maior predomin?ncia. Os tr?s subtipos morfol?gicos French-American-British foram detectados nas Leucemias Linfobl?sticas Agudas de linhagem B, sendo os tipos L1 e L2 mais freq?entemente observados nas Leucemia Linfobl?stica Aguda Calla+ com 72 e 25 casos, respectivamente. Os n?veis de express?o dos ant?genos T mostraram principalmente o CD3 (superf?cie e citoplasm?tico) com 8,33% e 11,17%, respectivamente. Para os ant?genos B observou-se uma maior freq??ncia de express?o para os ant?genos pan B: CD19, sCD22, cCD22 e cCD79a. Detectou-se a presen?a de fen?tipo aberrante em 66 casos. Conclus?es: O emprego sistem?tico dos anticorpos monoclonais e sua aplica??o na citometria de fluxo tem se confirmado ?til no diagn?stico diferencial das leucemias agudas, em adi??o ao diagn?stico morfol?gico
|
34 |
Intera??o de microorganismos na solubiliza??o de f?sforo e pot?ssio de rochas para produ??o de biofertilizantesSilva, Val?ria Nogueira da 03 May 2013 (has links)
Made available in DSpace on 2014-12-17T14:05:23Z (GMT). No. of bitstreams: 1
ValeriaNS_TESE.pdf: 2082797 bytes, checksum: 3f7c49154416ffa0bea9f055c45ea17e (MD5)
Previous issue date: 2013-05-03 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior / he present model of agriculture is based on intensive use of industrial inputs, due to its rapid response, but it brings harmful consequences to the environment, and it is necessary the use of modern inputs. And an alternative is the use of rock biofertilizers in agriculture, a product easy to use, with higher residual effect and does not harm the environment. The objective of study was to evaluate the inoculation and co-inoculation of different microorganisms in the solubilization of rock phosphate and potash ground microbial evaluating the best performance in the production of biofertilizers comparing with rocks pure in soil chemical properties and, verify effect of inoculation of the bacterium Paenibacillus polymyxa in the absorption of minerals dissolved in the development of cowpea (Vigna unguiculata [L.] Walp.). The first bioassay was conducted in Laboratory (UFRN) for 72 days in Petri dishes, where the rock powder was increased by 10% and sulfur co-inoculated and inoculated with bacterial suspension of Paenibacillus polymyxa grown in medium tryptone soy broth, Ralstonia solanacearum in medium Kelman, Cromobacterium violaceum in medium Luria-Bertani and Acidithiobacillus thiooxidans in medium Tuovinen and Kelly,and fungi Trichoderma humatum and Penicillium fellutanum in malt extract. Every 12 days, samples were removed in order to build up the release curve of minerals. The second bioassay was conducted in a greenhouse of the Agricultural Research Corporation of Rio Grande do Norte in experimental delineation in randomized block designs, was used 10 kg of an Yellow Argissolo Dystrophic per pot with the addition of treatments super phosphate simple (SS), potassium chloride (KCl), pure rock, biofertilizers in doses 40, 70, 100 and 200% of the recommendation for SS and KCl, and a control, or not inoculated with bacteria P. polymyxa. Were used seeds of cowpea BRS Potiguar and co-inoculated with the bacterial suspension of Bradyrhizobium japonicum and P. polymyxa. The first crop was harvested 45 days after planting, were evaluated in the dry matter (ADM), macronutrients (N, P, K, Ca, Mg) and micronutrients (Zn, Fe, Mn) in ADM. And the second at 75 days assessing levels of macro end micronutrients in plants and soil, and the maximum adsorption capacity of P in soil. The results showed synergism in co-inoculations with P. polymyxa+R. solanacearum and, P. polymyxa+C. violaceum solubilizations providing higher P and K, respectively, and better solubilization time at 36 days. The pH was lower in biofertilizers higher doses, but there was better with their addition to P at the highest dose. Significant reduction of maximum adsorption capacity of phosphorus with increasing dose of biofertilizer. For K and Ca was better with SS+KCl, and Mg to pure rock. There was an effect of fertilization on the absorption, with better results for P, K and ADM with SS+KCL, and N, Ca and Mg for biofertilizers. Generally, the P. polymyxa not influence the absorption of the elements in the plant. In treatments with the uninoculated P. polymyxa chemical fertilizer had an average significantly higher for weight and number of grains. And in the presence of the bacteria, biofertilizers and chemical fertilizers had positive values in relation to rock and control. The data show that the rocks and biofertilizers could meet the need of nutrients the plants revealed as potential for sustainable agriculture / A agricultura atual se baseia no uso intensivo de fertilizantes industrializados, por sua resposta r?pida, por?m traz consequ?ncias danosas ao ambiente, e faz-se necess?rio o uso de insumos modernos. Uma alternativa ? o uso de biofertilizantes de rochas na agricultura, um produto de f?cil manuseio, com efeito residual maior e n?o agride o meio ambiente. O objetivo do estudo foi avaliar a inocula??o e co-inocula??o de diferentes microrganismos na solubiliza??o de f?sforo e pot?ssio de rochas mo?das avaliando o melhor desempenho microbiano(s) na produ??o de biofertilizantes comparando com as rochas puras nas propriedades qu?micas do solo e, verificar o efeito da inocula??o da bact?ria Paenibacillus polymyxa na absor??o dos minerais solubilizados no desenvolvimento do feij?o caupi (Vigna unguiculata [L.] Walp.). O primeiro bioensaio foi conduzido em Laborat?rio (UFRN) por 72 dias em Placas de Petri, onde o p? de rocha era acrescido de 10% de enxofre e inoculados e co-inoculados com suspens?o bacteriana de Paenibacillus polymyxa cultivada em meio caldo triptona de soja, Ralstonia solanacearum em meio Kelman, Cromobacterium violaceum em meio Luria-Bertani e Acidithiobacillus thiooxidans em meio Tuovinen e Kelly, e os fungos Penicillium fellutanum e Tricoderma humatum em meio contendo extrato de malte. A cada 12 dias, amostras eram retiradas a fim de construir uma curva de libera??o dos minerais. O segundo bioensaio foi conduzido em casa de vegeta??o da Empresa de Pesquisa Agropecu?ria do Rio Grande do Norte, onde utilizou-se 10 kg do Argissolo Amarelo Distr?fico, por vaso, com adi??o dos tratamentos super fosfato simples (SS), cloreto de pot?ssio (KCl), rocha pura, biofertilizantes nas doses 40, 70, 100 e 200% da recomenda??o para SS e KCl, e uma testemunha, inoculados ou n?o com a bact?ria P. polymyxa. Foram utilizadas sementes da caupi BRS Potiguar e co-inoculadas com suspens?o bacteriana de Bradyrhizobium japonicum e P. polymyxa. A primeira colheita foi aos 45 dias de plantio avaliando a mat?ria seca da parte a?rea (MSPA), teores de macronutrientes (N, P, K, Ca, Mg,) e micronutrientes (Zn, Fe, Mn) na MSPA. A segunda colheita aos 75 dias avaliando teores de macro e micronutrientes na planta e no solo, e a capacidade m?xima de adsor??o de P (CMAP) no solo. Os resultados mostraram que houve sinergismo nas co-inocula??es com P. polymyxa+R. solanacearum e, P. polymyxa+C. violaceum com maiores solubiliza??es de K e P, respectivamente, e melhor tempo de solubiliza??o aos 36 dias. O pH foi mais reduzido nos biofertilizantes de maiores doses, e houve melhoras com sua adi??o para P na maior dose. Houve redu??o significativa da CMAP com o aumento da dose do biofertilizante. Houve efeito da fertiliza??o na absor??o, com melhoras para P, K e MSPA com SS+KCL, e N, Ca e Mg para biofertilizantes. De modo geral, o P. polymyxa n?o influenciou na absor??o dos elementos na planta. Para Ca e K houve melhoras com SS+KCl, e para Mg com rocha pura. O fertilizante qu?mico foi significativamente superior para peso e n?mero de gr?os, sem a presen?a do P. polymyxa. Na presen?a da bact?ria, biofertilizantes e fertilizante qu?mico apresentaram valores positivos em rela??o ? rocha e testemunha. Os dados evidenciaram que as rochas e os biofertilizantes podem suprir a necessidade de nutrientes ?s plantas revelando-se como potencial para uma agricultura sustent?vel
|
35 |
Avaliação da dose ocupacional em exame de uretrocistografia com equipamento de fluoroscopia / Occupational dose evaluation in urethrocystography exam with fluoroscopy equipmentBaroni, Keity Priscile 17 September 2015 (has links)
Ao longo da evolução dos equipamentos e exames radiológicos, a exposição dos pacientes e trabalhadores envolvidos tem aumentado em grande proporção. Esta exposição não deve ser subestimada, uma vez que acumulada ao longo dos anos pode trazer riscos para a saúde do indivíduo exposto. O objetivo deste trabalho foi verificar a taxa de exposição de trabalhadores à radiação ionizante. Foram realizadas simulações do exame de uretrocistografia utilizando-se de uma câmara de ionização, para verificar a taxa de exposição, colocando-se dosímetros termoluminescentes de em cada espalhador verificando a dose efetiva em locais específicos do corpo do indivíduo ocupacionalmente exposto durante o procedimento. A posição da mesa de exames foi variada durante a exposição para avaliar se esta tem influencia na dose recebida pelos trabalhadores. Os resultados revelaram uma grande diminuição da dose quando a posição da mesa está na horizontal. O aumento da distância dos espalhadores ao paciente teve uma diminuição significativa da taxa de exposição. A maioria dos resultados se apresentou abaixo dos limites preconizados, porém o dosímetro colocado na altura do tórax do espalhador posicionado mais próximo ao paciente excedeu este limite. Portanto, os procedimentos de trabalho devem ser sempre observados com o intuito de manter os limites dentro de um nível de segurança. / Throughout the evolution of radiological equipment and tests, the exposure of patients and workers involved has increased to a great extent. This exhibition should not be underestimated, since accumulated over the years can bring risks to the health of the exposed individual. The objective of this study was to determine the rate of exposure of workers in an X-ray room. Examining urethrocystography simulations were performed using an ionization chamber, to verify the exposure rate, and thermoluminescent dosimeters in each cap to check the effective dose in specific locations of the individual's body occupationally exposed in the examen. The position of the examination table was varied during exposure to assess whether this has influence on the dose received by the workers. The results showed a large decrease in dose when the table position is horizontally. Increased distance spreaders of the patient had a significant decrease in exposure rate. The majority of results presented below recommended limits, but the dosimeter positioned at the height of the thorax on the spreader lens closest to the patient exceeded this limit. Therefore, work procedures should always be observed in order to keep within the limits of a security level.
|
36 |
Caracterização e calibração de um sensor a fibra ótica baseado em redes de Bragg para análise biomecânica in vivo / Characterization and calibration of a fiber optical sensor based on Bragg gratings for biomechanical analysis in vivoKalinowski, Alessandra 26 April 2017 (has links)
CAPES / O presente trabalho estuda o comportamento de um biosensor que utiliza redes de Bragg em fibra ótica capaz de mensurar deformações em tecido ósseo. O objetivo é calibrar e caracterizar o sensor com seu encapsulamento para que este possa futuramente ser implantado em um animal vivo e assim permita aprimorar estudos a respeito do comportamento ósseo em sua microestrutura. Para o desenvolvimento deste estudo e preciso conhecer o comportamento ósseo como um todo, a biomecânica do local específico onde pretende-se implantar o sensor, o funcionamento do sensor, bem como o comportamento de seu encapsulamento; portanto, todos esses aspectos são estudados. Para caracterização e calibração do sensor encapsulado foi realizado teste de tração em um programa de computador (simulação numérica) e arranjo experimental de calibração (teste prático), para que seja possível sua aplicação final desejada. Os testes realizados são descritos neste trabalho. Os resultados obtidos demonstram que o transdutor e o encapsulamento utilizado são adequados para captar deforma coes inferiores a 0,1 N, apresentam resposta linear, com um coeficiente de correlação da média dos 5 sensores testados em 0,999, incerteza expandida de 0,07 N e coeficiente de carga de 77 pm/N; boa repetibilidade, e componentes biocompatíveis, sendo assim, o sensor e adequado para aplicações in vivo. Através dos testes também foi possível determinar o melhor local e maneira para sua implementação em uma aplicação específica, que e a análise de deformação óssea em uma superfície externa de mandíbula bovina durante movimentos mastigatórios de diferentes alimentos. / The present work studies behavior of a biosensor that uses Bragg gratings in optical fibers, capable to measuring deformations in bone tissue. The aim is to characterize and calibrate the sensor with its encapsulation so that it can be implanted in a living animal in the future and thus allow to improve studies about bone behavior in its microstructure. For the development of this study it is necessary to know the bone behavior as a whole, the biomechanics of the specific area where the sensor will be implanted, the sensor operation, as well as the behavior of its encapsulation; herefore, all these aspects are studied. For the characterization and calibration of the encapsulated sensor, a software traction test (numerical simulation) and an experimental calibration arrangement (practical test) were carried out, so that its desired final application could be possible. The tests performed are described in this work. The results show that the transducer and the encapsulation used are adequate to capture deformations lower than 0.1 N, presented a linear response, with a correlation coefficient of the average of 5 sensors at 0.999, expanded uncertainty of 0.07 N and slope 77 pm/N; good repeatability, and biocompatible components. The sensor is suitable for in vivo applications. Through the tests it was also possible to determine the best place and way for its implementation in a specific application, that is the analysis of bone deformation on an external surface of bovine mandible during chewing movements of different foods.
|
37 |
Desenvolvimento de equipamento para medir os intervalos R-R / Development of equipment to measure RR intervalsFarah, Leonardo 27 November 2015 (has links)
O presente estudo, teve como objetivo desenvolver um equipamento para medir os intervalos R-R, que tivesse alta correlação com os valores do aparelho padrão ouro de eletrocardiógrafo (ECG), pelos índices de domínio do tempo e domínio da frequência. Para tanto, foi realizado um estudo com 18 alunos de Jiu-Jitsu, do sexo masculino com 35,5±8,6 anos, no mínimo uma frequência semanal de 3 vezes e 1 ano de treinamento. O local foi na academia Barra Gracie de Curitiba PR. Foram submetidos a uma análise em repouso por um período de 7 minutos e posteriormente seus resultados foram convertidos em variabilidade da frequência cardíaca (VFC) e analisados pelos índices no domínio do tempo e domínio da frequência. Os resultados foram comparados estatisticamente por meio do teste de Pearson e a correlação intraclasse (ICC) e de acordo com eles mostra-se viável o desenvolvimento deste equipamento, que apresenta alta correlação e excelente replicabilidade para medir os intervalos R-R. / This study aimed to develop a device to measure RR intervals, which have high correlation with the values of the gold standard device of electrocardiograph (ECG), by the time domain and frequency domain indices. To this end, a study was conducted with 18 students of Jiu-Jitsu, males with 35.5 ± 8.6 years, at least a weekly frequency of 3 times and one year training. The location was at the academy Gracie Barra de Curitiba PR. They underwent an examination at rest for a period of 7 minutes and then the results were converted into heart rate variability (HRV) and analyzed by the indexes in the time domain and the frequency domain. The results were compared statistically using the Pearson test and intraclass correlation (ICC) and according to them proves to be viable the development of this equipment, which is highly correlated and excellent reproducibility for measuring the RR intervals.
|
38 |
Caracterização elementar de ligas metálicas em implantes dentários / Elementary characterization of metal alloys in dental implantsTorres, Catarina Alzira Montenegro Peddis 29 September 2015 (has links)
CAPES / Um biomaterial ideal para implantes dentários deve ter elevada biocompatibilidade e não provocar qualquer resposta adversa séria nos tecidos. Além disso, as ligas metálicas usadas precisam ser resistentes à fadiga devido às forças da mastigação e ser resistentes à corrosão. Estas características são conferidas as ligas metálicas pela adição dos elementos estabilizadores de fase como Al, V, Ni, Fe, Cu, Cr, Zn. O titânio comercialmente puro (TiCP) é o material mais indicado para fabricação de implantes dentários e ortopédicos. No entanto, outras ligas metálicas são utilizadas e há, portanto, a necessidade de investigar o tipo de elemento presente nestas e os possíveis riscos à saúde. O presente trabalho investigou os implantes comercializados como TiCP e a presença de elementos estabilizadores dentro ou fora dos limites esperados para estes materiais. Para a caracterização elementar foi utilizada técnica de EDXRF, a qual permite resultados quali- quantitativos. Um dos arranjos experimentais utilizado possui dois tubos de raios X modelo Mini-X com alvo de Au e Ag e detector X-123SDD (AMPTEK) e um colimador de Cu com 0,5mm de diâmetro, desenvolvido devido às características das amostras. O outro sistema de EDXRF é composto por um tubo de raios X com alvo de Mo, colimador de 0,65mm e um detector XFlash (SDD), o ARTAX 200 (BRUKER). O outro método de caracterização elementar, a espectroscopia de energia dispersiva (EDS), foi usada em conjunto com a Microscopia Eletrônica de Varredura (MEV) da marca EVO® (Zeeis), a qual serviu para avaliar a microestrurura de superfície dos implantes. O percentual de Ti obtido na caracterização elementar foi entre 93,35 ± 0,17% e 95,34 ± 0,19 %. Estes valores são considerados abaixo do limite de referência de 98,635% a 99,5% para o TiCP, segundo a Association of metals centric materials engineers and scientists Society (ASM). A presença de Al e V em todas as amostras também contribuiu para respaldar o fato de não serem implantes de TiCP. Os valores para o Al ficaram entre 6,3 ± 1,3% e 3,7 ± 2,0% e para o V entre 0,26 ± 0,09% e 0,112 ± 0,048%. Segundo a American Society for Testing and Materials (ASTM) estes elementos não devem estar presentes no TiCP e de acordo com o National Institute of Standards and Technology (NIST), a presença do Al deve ser < 0,01% e do V de 0,009 ± 0,001%. Como resultado, todos os implantes analisados são de uma liga de Ti- Al-V com adição de Fe, Ni, Cu e Zn. A análise qualitativa e caracterização para as medições com os diferentes tubos mostrou melhor eficácia com o uso do tubo de Au e colimador de 0,5 mm. O uso da técnica da EDS confirmou os resultados da EDXRF para uma liga de Ti-Al-V. E com o uso do MEV na análise da microestrutura dos implantes, foi possível inferir que dos 13 implantes, 10 possuem superfície rugosa, são contemporâneos e três possuem a superfície usinada. / An ideal biomaterial for dental implants must have very high biocompatibility, which means that such materials should not provoke any serious adverse tissue response. Also, used metal alloys must have high fatigue resistance due the masticatory force and good corrosion resistance. These properties are rendered by using alpha and beta stabilizers, such as Al, V, Ni, Fe, Cr, Cu, Zn. Commercially pure titanium (TiCP) is used often for dental and orthopedic implants manufacturing. However, sometimes other alloys are employed and consequently it is essential to research the chemical elements present in those alloys that could bring prejudice for the health. Present work investigated TiCP metal alloys used for dental implant manufacturing and evaluated the presence of stabilizing elements within existing limits and standards for such materials. For alloy characterization and identification of stabilizing elements it was used EDXRF technique. This method allows to perform qualitative and quantitative analysis of the materials using the spectra of the characteristic X-rays emitted by the elements present in the metal samples. The experimental setup was based on two X- rays tubes (AMPTEK Mini X model with Ag and Au targets), a X-123SDD detector (AMPTEK) and a 0.5mm Cu collimator, developed due to the sample characteristics. The other experimental setup used as a complementary technique is composed of an X-ray tube with a Mo target, collimator 0.65mm and XFlash (SDD) detector - ARTAX 200 (BRUKER). Other method for elemental characterization by energy dispersive spectroscopy (EDS) applied in present work was based on Scanning Electron Microscopy (SEM) EVO® (Zeeis). This method also was used to evaluate the surface microstructure of the sample. The percentual of Ti obtained in the elementary characterization was among 93.35 ± 0.17% and 95.34 ± 0.19 %. These values are considered below the reference limit of 98.635% to 99.5% for TiCP, established by Association of metals centric materials engineers and scientists Society (ASM). The presence of elements Al and V in all samples also contributed to underpin the fact that are not TiCP implants. The values for Al vary between 6.3 ± 1.3% and 3.7 ± 2.0% and for V, between 0.26 ± 0.09% and 0.112 ± 0.048%. According to the American Society for Testing and Materials (ASTM), these elements should not be present in TiCP and in accordance with the National Institute of Standards and Technology (NIST), the presence of Al should be <0.01% and V should be of 0.009 ± 0.001%. Obtained results showed that implant materials are not exactly TiCP but, were manufactured using Ti-Al-V alloy, which contained Fe, Ni, Cu and Zn. The quantitative analysis and elementary characterization of experimental results shows that the best accuracy and precision were reached with X-Ray tube with Au target and collimator of 0.5 mm. Use of technique of EDS confirmed the results of EDXRF for Ti-Al-V alloy. Evaluating the surface microstructure by SEM of the implants, it was possible to infer that ten of the thirteen studied samples are contemporaneous, rough surface and three with machined surface.
|
39 |
Medidas de duração de consoantes oclusivas como vestígios de fala em análise acústico-instrumental forense de amostras com e sem uso de disfarce / Stop consonants term measures as remains in forensic acoustic instrumental analysis of disguised and normal speechCarneiro, Denise de Oliveira 24 August 2016 (has links)
A atribuição de autoria a falas provenientes de gravações ambientais e interceptações telefônicas de falas que provêm de crimes como tráfico de drogas, estelionato, sequestro, abuso sexual, pedofilia, e corrupção pode apresentar à perícia vários dificultadores para a obtenção de medidas acústicas. Um desses dificultadores pode ser o disfarce de voz. Com a possibilidade de ter suas vozes gravadas, o disfarce tem se tornado comum entre os perpetradores de crimes. Quando a voz é gravada, poderá servir como prova a partir do exame de comparação de locutor (ECL), que reúne metodologias para determinar se duas amostras de fala provêm do mesmo falante. O ECL é realizado por meio de análise perceptivo-auditiva, acústico-instrumental e de reconhecimento automático. Embora já tenham sido desenvolvidas tecnologias de verificação automática, as análises sem interferência humana não apresentam respaldo suficiente, seja pela má qualidade do sinal ou pela escassez de amostras de fala em banco de dados e, por isso, as pesquisas que ancorem as outras modalidades de análise são essenciais. A análise acústico-instrumental emprega ferramentas computacionais para avaliação quantitativa e qualitativa da fala e a engenharia biomédica possibilita o desenvolvimento de tecnologias para instrumentação da análise do sinal de fala. Em busca de um parâmetro acústico que seja robusto em análises de disfarce de voz, este trabalho utilizou medidas de duração de fases de segmentos, que têm sido pouco exploradas em ECL. As consoantes oclusivas não vozeadas do português brasileiro [p, t, k] são produzidas em três fases distintas: fase de oclusão, fase de soltura e transição formântica. As duas primeiras fases apresentam correlatos acústicos que se destacam na visualização do oscilograma: silêncio relativo e produção de ondas aperiódicas. Nesta pesquisa, foram analisadas instrumentalmente as falas de 20 sujeitos, 10 do sexo masculino e 10 do sexo feminino, com idades entre 25 e 55 anos, durante a leitura, com e sem o uso de disfarce, de um texto que simulava uma situação criminosa. Foram obtidas medidas dos tempos de oclusão e soltura das consoantes não vozeadas e constatou-se que o contexto fonológico posterior influencia o tempo de produção. Verificaram-se medidas diferentes entre a primeira e a segunda leitura com uso do disfarce, indicando que o falante apresentou dificuldade na manutenção do ajuste fonatório e que, embora tenham sido encontradas diferenças entre as medidas obtidas em fala com e sem disfarce, a correlação é forte entre as mesmas. O tempo de oclusão aparentou comportamento menos influenciável pelo uso do disfarce para as sílabas [pi, pu, te, tɛ], enquanto o tempo de soltura demonstrou maior suscetibilidade, exceto em [pi, te]. Os resultados permitem que alguns dos segmentos analisados sejam considerados vestígios de autoria dentro de um conjunto probatório. / Authorship attribution of speech, from environmental recordings and telephone interceptions, which can be evidence of crimes related to drug dealing, racketeering, kidnapping, sexual abuse, pedophilia, and corruption, may present difficulties to experts in obtaining acoustic measures. One of these difficulties may be the use of disguise. With the possibility of being recorded, voice disguise has become common among crime perpetrators. When a voice is recorded, it can be an evidence after speaker comparison examination (SCE), which adopts methodologies to determine whether two speech samples have been produced by the same speaker. SCE can be perceptual, acoustic-instrumental and through automatic recognition. Although automatic recognition technologies have already been developed, analyses without human interference do not have enough support, both for poor signal quality or for lack of speech samples. Therefore, research that is anchored in other analysis methods are essential. Acoustic-instrumental analyses use computational tools for quantitative and qualitative evaluation of speech, and biomedical engineering enables the development of technologies and instrumentation for speech signal analyses. In search of an acoustic parameter that is robust in disguise analyses, this research used segment phase measurements, which have been little explored in SCE. Brazilian Portuguese voiceless stops [p, t, k] are produced in three distinct phases: occlusion phase, release phase and formant transition. The first two phases have acoustic correlates that are visually distinct in the oscillogram: relative silence and aperiodic wave production. In this research, the speech of 20 subjects were instrumentally analyzed, 10 males and 10 females, aged between 25 and 55 years, while reading, with and without the use of disguise, a text that simulated a criminal situation. Occlusion and release duration of the voiceless stop consonants were measured and it was found that the phonological context influences the production time. Different measures were found between the first and the second reading with disguised voice, indicating that the speaker had difficulty in maintaining the phonation setting, and that, although there were differences between the measures in speech with and without disguise, the correlation between them was strong. Occlusion time appeared to be less influenced by the use of disguise for the syllables [pi, pu, te, tɛ], while the release time showed greater susceptibility, except for [pi, te]. The results allow that some of the segments analyzed be considered vestiges of authorship within a body of evidence.
|
40 |
Avaliação da dose ocupacional em exame de uretrocistografia com equipamento de fluoroscopia / Occupational dose evaluation in urethrocystography exam with fluoroscopy equipmentBaroni, Keity Priscile 17 September 2015 (has links)
Ao longo da evolução dos equipamentos e exames radiológicos, a exposição dos pacientes e trabalhadores envolvidos tem aumentado em grande proporção. Esta exposição não deve ser subestimada, uma vez que acumulada ao longo dos anos pode trazer riscos para a saúde do indivíduo exposto. O objetivo deste trabalho foi verificar a taxa de exposição de trabalhadores à radiação ionizante. Foram realizadas simulações do exame de uretrocistografia utilizando-se de uma câmara de ionização, para verificar a taxa de exposição, colocando-se dosímetros termoluminescentes de em cada espalhador verificando a dose efetiva em locais específicos do corpo do indivíduo ocupacionalmente exposto durante o procedimento. A posição da mesa de exames foi variada durante a exposição para avaliar se esta tem influencia na dose recebida pelos trabalhadores. Os resultados revelaram uma grande diminuição da dose quando a posição da mesa está na horizontal. O aumento da distância dos espalhadores ao paciente teve uma diminuição significativa da taxa de exposição. A maioria dos resultados se apresentou abaixo dos limites preconizados, porém o dosímetro colocado na altura do tórax do espalhador posicionado mais próximo ao paciente excedeu este limite. Portanto, os procedimentos de trabalho devem ser sempre observados com o intuito de manter os limites dentro de um nível de segurança. / Throughout the evolution of radiological equipment and tests, the exposure of patients and workers involved has increased to a great extent. This exhibition should not be underestimated, since accumulated over the years can bring risks to the health of the exposed individual. The objective of this study was to determine the rate of exposure of workers in an X-ray room. Examining urethrocystography simulations were performed using an ionization chamber, to verify the exposure rate, and thermoluminescent dosimeters in each cap to check the effective dose in specific locations of the individual's body occupationally exposed in the examen. The position of the examination table was varied during exposure to assess whether this has influence on the dose received by the workers. The results showed a large decrease in dose when the table position is horizontally. Increased distance spreaders of the patient had a significant decrease in exposure rate. The majority of results presented below recommended limits, but the dosimeter positioned at the height of the thorax on the spreader lens closest to the patient exceeded this limit. Therefore, work procedures should always be observed in order to keep within the limits of a security level.
|
Page generated in 0.0296 seconds