• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 42
  • 13
  • 2
  • 1
  • 1
  • Tagged with
  • 74
  • 74
  • 36
  • 33
  • 19
  • 18
  • 16
  • 14
  • 14
  • 12
  • 12
  • 12
  • 12
  • 11
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Efeitos interativos da pressão expiratória final positiva (PEEP) e da fração inspirada de oxigênio (FIO2) no colapso pulmonar durante anestesia geral em modelo experimental suíno / Interactive effects of positive-end expiratory pressure (PEEP) and fraction of inspired oxygen (FIO2) on pulmonary collapse during general anesthesia in experimental swine model

Melo, José Renato de 25 October 2017 (has links)
INTRODUÇÃO: O desenvolvimento de colapso pulmonar (atelectasia) durante anestesia geral com ventilação mecânica é frequente, podendo determinar hipoxemia e contribuir para desenvolvimento de outras complicações pós-operatórias, como infecção e síndrome do desconforto respiratório agudo (SDRA). O uso de fração inspirada de oxigênio (FIO2) baixa e de pressão expiratória final positiva (PEEP) podem reduzir a quantidade de pulmão atelectasiado. Existem poucos dados experimentais sobre a cinética do desenvolvimento da atelectasia no intraoperatório em diferentes ajustes de FIO2 e PEEP no decorrer do tempo. A Tomografia de impedância elétrica (TIE) do tórax permite uma análise contínua e não invasiva da função pulmonar, bem como da quantificação do colapso e pode ser usada no intraoperatório. OBJETIVOS: a) avaliar, em animais com pulmões sadios durante anestesia geral, o efeito do uso de uma PEEP individualizada escolhida através da TIE (\"PEEP titulada\"), na formação de colapso; b) analisar a magnitude e a cinética de desenvolvimento do colapso pulmonar no decorrer do período de uma hora em dois valores de FIO2 (0,4 e 1) e dois valores de PEEP (3 cmH2O e valor da PEEP titulada) através da TIE e Tomografia computadorizada (TC); c) analisar mecânica, ventilação regional e aeração pela TIE e troca gasosa nos diferentes períodos do estudo. MÉTODOS: Nove animais (suínos) com pulmão normal foram submetidos à manobra de titulação da PEEP para escolha da PEEP que determina colapso pulmonar mínimo (colapso menor que 3% determinado pela TIE, denominada \"PEEP titulada\") e posteriormente ventilados com volume corrente de 6ml/Kg em quatro ajustes, em sequência randomizada, por um período de 1 hora: FIO2 0,4 e PEEP 3, FIO2 0,4 e PEEP titulada, FIO2 1 e PEEP 3 e FIO2 1 e PEEP titulada. O colapso, ventilação regional e aeração foram medidos continuamente, através da TIE assim como dados da mecânica. Mensuramos troca gasosa e aeração pulmonar pela TC em 3 momentos em cada período do estudo (baseline, 5 e 50 minutos). RESULTADOS: A PEEP titulada foi de 11,6 ±1,4 cm H2O. Houve colapso progressivo no decorrer do tempo nos 4 grupos estudados tendo sido maior na PEEP 3 que na PEEP titulada. A medida do colapso pela TIE não foi influenciada pela FIO2 utilizada, ao contrário da mensuração pela TC na qual o colapso foi maior na FIO2 de 1. Houve queda da complacência pulmonar e aumento da pressão de distensão no decorrer do tempo, maiores na PEEP 3, sem influência da FIO2. Na região dorsal, a TIE evidenciou redução da ventilação (delta Z) na PEEP 3, sem influência da FIO2, e, também, redução da aeração (mínimo Z) que foi maior na PEEP 3 e na FIO2 de 1. Houve queda da relação PaO2/FIO2 e aumento do shunt e mistura venosa na PEEP 3. Não houve alterações hemodinâmicas clinicamente relevantes durante o estudo. CONCLUSÕES: Houve colapso progressivo no decorrer do tempo, sendo maior na PEEP 3 que na PEEP titulada. O colapso aferido pela TC foi maior na FIO2 de 1 do que na 0,4 para uma mesma PEEP, diferente da TIE cuja estimativa de colapso não foi diferente. Paralelamente houve queda da complacência pulmonar, aumento da pressão de distensão e redução da ventilação dorsal, maiores na PEEP 3 e sem influência da FIO2. A queda da aeração estimada pela TIE foi maior na PEEP 3, sendo que nas duas PEEP a aeração foi menor na FIO2 de 1 / INTRODUCTION: The development of pulmonary collapse (atelectasis) during general anesthesia with mechanical ventilation is frequent, which can determine hypoxemia and contribute to the development of other postoperative complications, such as infection and acute respiratory distress syndrome (ARDS). The use of low fraction of inspired oxygen (FIO2) and positive end expiratory pressure (PEEP) may reduce the amount of collapsed lung. There are few experimental data on the kinetics of intraoperative atelectasis development in different FIO2 and PEEP adjustments over time. Electrical impedance tomography (EIT) of the thorax allows a continuous and noninvasive analysis of pulmonary function as well as the quantification of pulmonary atelectasis and can be used intraoperatively. OBJECTIVES: a) to evaluate, in animals with healthy lungs during general anesthesia, the effect of the use of an individualized PEEP chosen through EIT (titrated PEEP), in the formation of collapse; b) to analyze the magnitude and development kinetics of pulmonary collapse during the one-hour period in two values of FIO2 (0.4 and 1) and two PEEP values (3 cmH2O and titrated PEEP value) through EIT and computed tomography (CT); c) to analyze mechanics, regional ventilation and aeration by EIT and gas exchange in the different periods of the study. METHODS: Nine animals (swine) with normal lung were submitted to a PEEP titration maneuver to select PEEP that determines minimal pulmonary collapse (collapse of less than 3% determined by EIT, called \"titrated PEEP\") and then ventilated with a tidal volume of 6ml / kg in four adjustments, in a randomized sequence, for a period of 1 hour: FIO2 0.4 and PEEP 3, FIO2 0.4 and titrated PEEP, FIO2 1 and PEEP 3 and FIO2 1 and titrated PEEP. The collapse, regional ventilation and aeration were measured continuously through EIT as well as mechanics data. We also measured gas exchange and aeration by CT at 3 times in each study period (baseline, 5 e 50 minutes). RESULTS: The titrated PEEP was 11.6 ±1.4 cm H2O. There was a progressive collapse over time in the 4 groups studied, having been higher in PEEP 3 than in titrated PEEP. The measurement of EIT collapse was not influenced by the FIO2 used, as opposed to the CT measurement in which the collapse was greater in the FIO2 1. There was a decrease in pulmonary compliance and an increase in drive pressure over time, higher in PEEP 3, without influence of FIO2. In the dorsal region, EIT showed a decrease in ventilation, as measured by delta Z, in PEEP 3, with no influence of FIO2; there was also reduction of aeration, measured by the minimum Z, higher in PEEP 3 and FIO2 of 1. There was a decrease in the PaO2 / FIO2 ratio and increased in shunt and venous admixture in PEEP 3. There was no clinically relevant change in hemodynamics during the study. CONCLUSIONS: There was a greater collapse in PEEP 3 than in titrated PEEP over time. Collapse measured by CT was higher in FIO2 of 1 than 0.4 for the same PEEP, different from EIT estimates of collapse which was not different. Beside the collapse, there were decrease in compliance, increase in driving pressure and reduction of dorsal ventilation, higher in PEEP 3 without FIO2 influence. The decrease of aeration estimated by EIT was higher in PEEP 3 and for both PEEP values aeration was lower with FIO2 of 1
62

Avaliação da correlação entre a tomografia de impedância elétrica e o volume corrente aplicado durante o suporte ventilatório mecânico invasivo / Evaluation of the correlation between electrical impedance tomography and tidal volume applied during mechanical invasive ventilatory support

Adriana Sayuri Hirota 12 December 2018 (has links)
Introdução: A tomografia de impedância elétrica (TIE) é uma técnica de imagem não invasiva que mensura o potencial elétrico na superfície torácica através de eletrodos colocados ao redor do tórax. Essas medidas são transformadas em uma imagem bidimensional da distribuição da impedância elétrica no tórax. Esse instrumento detecta modificações da densidade pulmonar e distribuição do volume corrente. Entretanto, é necessário melhor avaliação da sua eficiência em estimar o volume corrente (VT) a cada ciclo ventilatório. O objetivo do estudo é avaliar a correlação do volume estimado pela TIE com o VT aplicado durante o suporte ventilatório mecânico. Métodos: Inicialmente, foram estudados cinco suínos da raça Landrace. Os animais foram sedados, intubados e monitorados com a TIE. Foram aplicados volumes incrementais (100, 250, 500, 750 e 1000 mL) com a seringa de precisão em ZEEP e com PEEP de 5, 10 e 20 cmH2O, antes e depois da promoção de lesão pulmonar com lavagem com solução salina. Posteriormente, outros cinco animais foram monitorados com a tomografia computadorizada de tórax por raios X (TC) e a TIE. Foram aplicados volumes incrementais (250, 500 e 1000 mL) com a seringa de precisão em ZEEP e com PEEP de 10 e 20 cmH2O, também antes e depois da promoção de lesão pulmonar. A amplitude da variação de impedância mensurada pela TIE foi convertida em volume e foi calculado o volume de ar na TC. Análises de correlação e concordância foram realizadas com o programa \"R\" (© R Foundation for Statistical Computing). Resultados: Em ZEEP, o coeficiente de correlação entre os volumes estimado pela TIE e calculado pela TC foram, respectivamente, 0,90 e 0,96 na comparação com a seringa de precisão. O coeficiente de determinação entre a TIE e a seringa de precisão foi progressivamente reduzindo (0,90; 0,89 e 0,81 com PEEP de 5; 10 e 20, respectivamente) com o aumento do volume pulmonar promovido pela elevação da PEEP. A TC mostrou um deslocamento progressivo do conteúdo aéreo no sentido caudal com o aumento do volume pulmonar. Conclusões: Há uma boa correlação entre o volume estimado pela TIE e o VT aplicado durante o suporte ventilatório mecânico quando utilizados volumes e pressões usuais na prática clínica / Rationale: Electrical impedance tomography (EIT) is a noninvasive imaging tool that reconstructs a cross-sectional image of the lung\'s regional conductivity using electrodes placed circumferentially around the thorax. It is able to detect changes of lung air content and tidal volume (VT) distribution. However, better evaluation of its capacity to quantify VT variations is necessary. The aim of our study was to assess the correlation between volume estimated by EIT and tidal volume applied at different positive end-expiratory pressures (PEEP). Methods: Initially, in an experimental study five mechanically ventilated pigs monitored by EIT were studied. VT increments (100, 250, 500, 750 and 1000 mL) were applied with a calibrated syringe at zero end-expiratory pressure (ZEEP) and PEEP levels of 5, 10 and 20 cmH2O before and after lung-injury (induced by saline lavage). Another five pigs was monitored by EIT and x-ray computed tomography (CT). VT increments (250, 500 and 1000 mL) were applied with a calibrated syringe at zero end-expiratory pressure (ZEEP) and PEEP levels of 10 and 20 cmH2O before and after lung-injury. Lung air volume was calculated at CT scan and the amplitude of impedance change measured by EIT was converted to volume (mL). Correlation and agreement analysis was performed at \"R\" program (© R Foundation for Statistical Computing). Results: At ZEEP, volume estimated by EIT and volume calculated at CT obtained r2 = 0.90 and 0.96 respectively, when compared to calibrated syringe. The coefficient of correlation between EIT and calibrated syringe impaired (0.90; 0.89 and 0.81 with PEEP of 5; 10 and 20, respectively) with increase of the lung volume due to increased PEEP. CT showed a progressive displacement of the air content to the caudal thoracic levels with the increase of the lung volume. Conclusion: EIT is able to estimate tidal volume during mechanical ventilatory support when used volumes and pressures usually applied at bedside
63

Titulação da PEEP rápida versus lenta guiadas por tomografia de impedância elétrica em pacientes hipoxêmicos no pós-operatório imediato de cirurgia cardíaca: estudo clínico randomizado / Fast versus slow PEEP trial guided by electrical impedance tomography in hypoxemic patients following cardiac surgery: randomized controlled trial

Nakamura, Maria Aparecida Miyuki 04 April 2018 (has links)
OBJETIVO: avaliar a concordância entre duas titulações decrementais de PEEP guiadas por tomografia de impedância elétrica (TIE): uma rápida, com tempo total inferior a 7 minutos, e uma lenta, com 40 minutos, e comparar os efeitos hemodinâmicos causados pelas duas titulações; e como objetivo secundário, comparar os efeitos fisiológicos da PEEP ótima escolhida pela TIE com a PEEP escolhida pela tabela PEEP-FiO2 do ARDSNet, durante 4 horas de ventilação mecânica. MÉTODOS: Trata-se de um estudo clínico, randomizado, unicêntrico que incluiu pacientes hipoxêmicos no pós-operatório imediato de cirurgia cardíaca. Os pacientes foram randomizados em 3 grupos: Titulação Rápida, Titulação Lenta ou Controle (tabela PEEP-FiO2 do ARDSNet). Os grupos Titulação Rápida e Titulação Lenta foram submetidos a duas titulações de PEEP guiadas pela TIE (uma rápida e uma lenta) precedidas de manobra de recrutamento alveolar. A titulação da PEEP foi realizada da PEEP de 23 cmH2O até a PEEP de 5 cmH2O, em passos decrementais de 2 cmH2O, com duas durações: 40 segundos na Titulação Rápida ( < 7 minutos no total), ou 4 minutos na Titulação Lenta (40 minutos no total). A PEEP ótima (PEEPTIT) foi definida como a menor PEEP com menos de 5% de colapso estimado pela TIE. No grupo Controle, a PEEP foi ajustada de acordo com a oxigenação, baseada no protocolo ARDSNet. Todos os pacientes permaneceram em ventilação mecânica por 4 horas com a PEEP de acordo com seu grupo, e foram monitorados com TIE durante todo estudo. A comparação entre as manobras de Titulação Rápida e Lenta incluiu as seguintes variáveis: colapso recrutável e hiperdistensão estimados pela TIE, valor da PEEPTIT, menor pressão arterial média e dose de noradrenalina durante as titulações. A comparação com o grupo controle incluiu: nível de PEEP, complacência do sistema respiratório, driving pressure, colapso e hiperdistensão estimados pela TIE (associação entre o ZMIN - que representa a aeração - e a Complacência Z avaliados regionalmente), e oxigenação (PaO2/FiO2) ao longo das 4 horas de acompanhamento. RESULTADOS: Não houve diferença entre colapso e hiperdistensão estimados pela Titulação Rápida e Lenta, nem nos valores de PEEPTIT (13 ± 4 vs 14 ± 4 cmH2O, P=0,13). A pressão arterial média foi maior durante a titulação rápida (92mmHg [IQ25-75%: 81-111] vs 83mmHg [71-93], P=0,035) e não houve diferença no uso de noradrenalina. A PEEPTIT pela TIE foi significativamente mais alta do que a PEEP do Grupo Controle. Os grupos Titulação Rápida e Lenta apresentaram comportamentos semelhantes após ajuste da PEEPTIT, e houve aumento significativo na complacência do sistema respiratório no primeiro minuto, que permaneceu maior que a condição basal ao final das 4 horas (T. Lenta: 0,73 ± 0,2 vs 0,89 ± 0,1 mL/cmH2O/Kg do peso predito, P < 0,001; T. Rápida: 0,7 ± 0,1 vs 0,85 ± 0,2 mL/cmH2O/Kg do peso predito, P < 0,001); com a melhora da complacência houve redução da driving pressure e, ao final das 4 horas, esta permaneceu menor que no tempo basal. No grupo controle, a complacência não mudou durante as 4 horas de ventilação mecânica (0,63 ± 0,1 vs 0,58 ± 0,1 mL/cmH2O/Kg do peso predito, P=0,34) e a driving pressure aumentou significativamente. A oxigenação melhorou nos três grupos, mas foi mais alta nos grupos PEEPTIT guiados pela TIE. Após ajuste da PEEPTIT, em ambos os grupos (Titulação Rápida e Lenta) houve aumento da aeração nas regiões dependente e não dependente, recrutamento na região dependente e não houve hiperdistensão na região não dependente, mesmo com a PEEP mais alta. No grupo controle, de acordo com a tabela PEEP-FiO2, a necessidade de PEEP diminuiu ao longo do tempo (6,1 ± 1,4 cmH2O no tempo 4 horas), causando redução da aeração. CONCLUSÕES: Houve concordância entre titulações rápida e lenta guiadas pela TIE em relação à PEEPTIT, estimativa de colapso e hiperdistensão para cada passo de PEEP; a titulação rápida da PEEP pôde ser realizada com menor repercussão hemodinâmica quando comparada com a titulação convencional lenta. A PEEP individualizada pela TIE melhorou a complacência, reduziu a driving pressure e melhorou a oxigenação, sem causar hiperdistensão quando comparada com protocolo ARDSNet. Descritores: respiração com pressão positiva; mecânica respiratória; impedância elétrica; tomografia; procedimentos cirúrgicos cardíacos; respiração artificial; insuficiência respiratória; tomografia de impedância elétrica / OBJECTIVE: to assess the agreement of \"optimum-PEEP\" values selected by two decremental PEEP trials guided by electrical impedance tomography (EIT): a Fast one lasting less than 7 minutes, and a Slow one lasting 40 minutes, and to compare the hemodynamic effects caused by these two trials; as secondary objectives, we aimed at comparing the physiological effects of the optimum-PEEP chosen by EIT (Fast or Slow) with those chosen by ARDSNet PEEP-FiO2 table during the subsequent 4 hours of mechanical ventilation. METHODS: in this single center, randomized controlled trial, hypoxemic patients immediately after cardiac surgery were randomized into three groups: Fast Titration (FAST-EIT), Slow Titration (SLOW-EIT) and Control (ARDSNet PEEP-FiO2 table). After recruiting maneuvers, and starting from a PEEP of 23 cmH2O, the FAST-EIT and SLOW-EIT groups were submitted to decremental PEEP trials, in steps of 2 cmH2O, until reaching 5 cmH2O, with two different durations: 40 seconds (the entire maneuver lasted < 7 minutes) or 4 minutes (entire maneuver lasted 40 minutes). The optimum-PEEP (PEEPTIT) was defined as the lowest PEEP with less than 5% of collapse estimated by EIT. In the control group, PEEP was adjusted according to oxygenation based on ARDSNet protocol. All patients were ventilated for 4 hours with PEEP according to their randomized groups, and all were monitored with EIT during the study. The comparison between Fast and Slow PEEP trials included: recruitable collapse and hyperdistension estimated by EIT, level of optimum PEEP, lowest mean arterial pressure and norepinephrine doses during the trials. The comparison with the control group included: level of PEEP, compliance and driving pressure, collapse (aeration) and hyperdistension estimated with EIT, and oxygenation (PaO2/FiO2) during 4 hours of mechanical ventilation. RESULTS: There was no difference between recruitable collapse and hyperdistension estimated by EIT between Fast and Slow maneuvers, as well as for the PEEPTIT (13 ± 4 vs 14 ± 4 cmH2O, P=0.13). Mean arterial pressure was higher during the Fast maneuver in comparison to the Slow maneuver (92mmHg [IQ25-75%: 81-111] vs 83mmHg [71-93], P=0.035), without differences in norepinephrine. FAST-EIT and SLOW-EIT groups presented similar changes during the time: after set PEEPTIT there was an immediate and significant improvement in respiratory-system compliance, which remained above baseline condition during the 4 hours of mechanical ventilation (SLOW-EIT: from 0.73 ± 0.2 to 0.89 ± 0.1 mL/cmH2O/Kg of PBW, P < 0.001; FAST-EIT: from 0.7 ± 0.1 to 0.85 ± 0.2 mL/cmH2O/Kg of PBW, P < 0.001); as respiratory compliance improved, driving pressure significantly reduced and remained lower than the baseline condition after 4 hours. In the control group, respiratory compliance did not change between baseline and 4 hours (from 0.63 ± 0.1 to 0.58 ± 0.1 mL/cmH2O/Kg of PBW, P=0.34) but driving pressure significantly increased as PEEP decreased. Oxygenation improved in all groups, but it was higher in the EIT groups. After setting PEEPTIT in both EIT groups (Fast or Slow), there was an increase in aeration in both, nondependent and dependent regions. In contrast, regional compliance increased in the dependent region and didn\'t change in nondependent region, suggesting that the strategy caused long-lasting recruitment of dependent regions and did not produced hyperdistension of non-dependent lung. In the control group, the required PEEP, adjusted by ARDSNet PEEP-FiO2 table, decreased along the time, causing evident collapse in EIT derived signals. CONCLUSION: There was no difference between recruitable collapse and hyperdistension estimated by EIT and PEEPTIT between Fast and Slow maneuvers; Fast PEEP trial guided by EIT could be performed in less than 7 minutes, with less hemodynamic consequences than the traditional Slow maneuver. Individualized PEEP guided by EIT improved respiratory compliance, reduced driving pressure and improved oxygenation without causing hyperdistension - when compared to a PEEP set according the ARDSNet protocol
64

Titulação da PEEP rápida versus lenta guiadas por tomografia de impedância elétrica em pacientes hipoxêmicos no pós-operatório imediato de cirurgia cardíaca: estudo clínico randomizado / Fast versus slow PEEP trial guided by electrical impedance tomography in hypoxemic patients following cardiac surgery: randomized controlled trial

Maria Aparecida Miyuki Nakamura 04 April 2018 (has links)
OBJETIVO: avaliar a concordância entre duas titulações decrementais de PEEP guiadas por tomografia de impedância elétrica (TIE): uma rápida, com tempo total inferior a 7 minutos, e uma lenta, com 40 minutos, e comparar os efeitos hemodinâmicos causados pelas duas titulações; e como objetivo secundário, comparar os efeitos fisiológicos da PEEP ótima escolhida pela TIE com a PEEP escolhida pela tabela PEEP-FiO2 do ARDSNet, durante 4 horas de ventilação mecânica. MÉTODOS: Trata-se de um estudo clínico, randomizado, unicêntrico que incluiu pacientes hipoxêmicos no pós-operatório imediato de cirurgia cardíaca. Os pacientes foram randomizados em 3 grupos: Titulação Rápida, Titulação Lenta ou Controle (tabela PEEP-FiO2 do ARDSNet). Os grupos Titulação Rápida e Titulação Lenta foram submetidos a duas titulações de PEEP guiadas pela TIE (uma rápida e uma lenta) precedidas de manobra de recrutamento alveolar. A titulação da PEEP foi realizada da PEEP de 23 cmH2O até a PEEP de 5 cmH2O, em passos decrementais de 2 cmH2O, com duas durações: 40 segundos na Titulação Rápida ( < 7 minutos no total), ou 4 minutos na Titulação Lenta (40 minutos no total). A PEEP ótima (PEEPTIT) foi definida como a menor PEEP com menos de 5% de colapso estimado pela TIE. No grupo Controle, a PEEP foi ajustada de acordo com a oxigenação, baseada no protocolo ARDSNet. Todos os pacientes permaneceram em ventilação mecânica por 4 horas com a PEEP de acordo com seu grupo, e foram monitorados com TIE durante todo estudo. A comparação entre as manobras de Titulação Rápida e Lenta incluiu as seguintes variáveis: colapso recrutável e hiperdistensão estimados pela TIE, valor da PEEPTIT, menor pressão arterial média e dose de noradrenalina durante as titulações. A comparação com o grupo controle incluiu: nível de PEEP, complacência do sistema respiratório, driving pressure, colapso e hiperdistensão estimados pela TIE (associação entre o ZMIN - que representa a aeração - e a Complacência Z avaliados regionalmente), e oxigenação (PaO2/FiO2) ao longo das 4 horas de acompanhamento. RESULTADOS: Não houve diferença entre colapso e hiperdistensão estimados pela Titulação Rápida e Lenta, nem nos valores de PEEPTIT (13 ± 4 vs 14 ± 4 cmH2O, P=0,13). A pressão arterial média foi maior durante a titulação rápida (92mmHg [IQ25-75%: 81-111] vs 83mmHg [71-93], P=0,035) e não houve diferença no uso de noradrenalina. A PEEPTIT pela TIE foi significativamente mais alta do que a PEEP do Grupo Controle. Os grupos Titulação Rápida e Lenta apresentaram comportamentos semelhantes após ajuste da PEEPTIT, e houve aumento significativo na complacência do sistema respiratório no primeiro minuto, que permaneceu maior que a condição basal ao final das 4 horas (T. Lenta: 0,73 ± 0,2 vs 0,89 ± 0,1 mL/cmH2O/Kg do peso predito, P < 0,001; T. Rápida: 0,7 ± 0,1 vs 0,85 ± 0,2 mL/cmH2O/Kg do peso predito, P < 0,001); com a melhora da complacência houve redução da driving pressure e, ao final das 4 horas, esta permaneceu menor que no tempo basal. No grupo controle, a complacência não mudou durante as 4 horas de ventilação mecânica (0,63 ± 0,1 vs 0,58 ± 0,1 mL/cmH2O/Kg do peso predito, P=0,34) e a driving pressure aumentou significativamente. A oxigenação melhorou nos três grupos, mas foi mais alta nos grupos PEEPTIT guiados pela TIE. Após ajuste da PEEPTIT, em ambos os grupos (Titulação Rápida e Lenta) houve aumento da aeração nas regiões dependente e não dependente, recrutamento na região dependente e não houve hiperdistensão na região não dependente, mesmo com a PEEP mais alta. No grupo controle, de acordo com a tabela PEEP-FiO2, a necessidade de PEEP diminuiu ao longo do tempo (6,1 ± 1,4 cmH2O no tempo 4 horas), causando redução da aeração. CONCLUSÕES: Houve concordância entre titulações rápida e lenta guiadas pela TIE em relação à PEEPTIT, estimativa de colapso e hiperdistensão para cada passo de PEEP; a titulação rápida da PEEP pôde ser realizada com menor repercussão hemodinâmica quando comparada com a titulação convencional lenta. A PEEP individualizada pela TIE melhorou a complacência, reduziu a driving pressure e melhorou a oxigenação, sem causar hiperdistensão quando comparada com protocolo ARDSNet. Descritores: respiração com pressão positiva; mecânica respiratória; impedância elétrica; tomografia; procedimentos cirúrgicos cardíacos; respiração artificial; insuficiência respiratória; tomografia de impedância elétrica / OBJECTIVE: to assess the agreement of \"optimum-PEEP\" values selected by two decremental PEEP trials guided by electrical impedance tomography (EIT): a Fast one lasting less than 7 minutes, and a Slow one lasting 40 minutes, and to compare the hemodynamic effects caused by these two trials; as secondary objectives, we aimed at comparing the physiological effects of the optimum-PEEP chosen by EIT (Fast or Slow) with those chosen by ARDSNet PEEP-FiO2 table during the subsequent 4 hours of mechanical ventilation. METHODS: in this single center, randomized controlled trial, hypoxemic patients immediately after cardiac surgery were randomized into three groups: Fast Titration (FAST-EIT), Slow Titration (SLOW-EIT) and Control (ARDSNet PEEP-FiO2 table). After recruiting maneuvers, and starting from a PEEP of 23 cmH2O, the FAST-EIT and SLOW-EIT groups were submitted to decremental PEEP trials, in steps of 2 cmH2O, until reaching 5 cmH2O, with two different durations: 40 seconds (the entire maneuver lasted < 7 minutes) or 4 minutes (entire maneuver lasted 40 minutes). The optimum-PEEP (PEEPTIT) was defined as the lowest PEEP with less than 5% of collapse estimated by EIT. In the control group, PEEP was adjusted according to oxygenation based on ARDSNet protocol. All patients were ventilated for 4 hours with PEEP according to their randomized groups, and all were monitored with EIT during the study. The comparison between Fast and Slow PEEP trials included: recruitable collapse and hyperdistension estimated by EIT, level of optimum PEEP, lowest mean arterial pressure and norepinephrine doses during the trials. The comparison with the control group included: level of PEEP, compliance and driving pressure, collapse (aeration) and hyperdistension estimated with EIT, and oxygenation (PaO2/FiO2) during 4 hours of mechanical ventilation. RESULTS: There was no difference between recruitable collapse and hyperdistension estimated by EIT between Fast and Slow maneuvers, as well as for the PEEPTIT (13 ± 4 vs 14 ± 4 cmH2O, P=0.13). Mean arterial pressure was higher during the Fast maneuver in comparison to the Slow maneuver (92mmHg [IQ25-75%: 81-111] vs 83mmHg [71-93], P=0.035), without differences in norepinephrine. FAST-EIT and SLOW-EIT groups presented similar changes during the time: after set PEEPTIT there was an immediate and significant improvement in respiratory-system compliance, which remained above baseline condition during the 4 hours of mechanical ventilation (SLOW-EIT: from 0.73 ± 0.2 to 0.89 ± 0.1 mL/cmH2O/Kg of PBW, P < 0.001; FAST-EIT: from 0.7 ± 0.1 to 0.85 ± 0.2 mL/cmH2O/Kg of PBW, P < 0.001); as respiratory compliance improved, driving pressure significantly reduced and remained lower than the baseline condition after 4 hours. In the control group, respiratory compliance did not change between baseline and 4 hours (from 0.63 ± 0.1 to 0.58 ± 0.1 mL/cmH2O/Kg of PBW, P=0.34) but driving pressure significantly increased as PEEP decreased. Oxygenation improved in all groups, but it was higher in the EIT groups. After setting PEEPTIT in both EIT groups (Fast or Slow), there was an increase in aeration in both, nondependent and dependent regions. In contrast, regional compliance increased in the dependent region and didn\'t change in nondependent region, suggesting that the strategy caused long-lasting recruitment of dependent regions and did not produced hyperdistension of non-dependent lung. In the control group, the required PEEP, adjusted by ARDSNet PEEP-FiO2 table, decreased along the time, causing evident collapse in EIT derived signals. CONCLUSION: There was no difference between recruitable collapse and hyperdistension estimated by EIT and PEEPTIT between Fast and Slow maneuvers; Fast PEEP trial guided by EIT could be performed in less than 7 minutes, with less hemodynamic consequences than the traditional Slow maneuver. Individualized PEEP guided by EIT improved respiratory compliance, reduced driving pressure and improved oxygenation without causing hyperdistension - when compared to a PEEP set according the ARDSNet protocol
65

Papel da tomografia de impedância elétrica em pacientes portadores de hipertensão arterial pulmonar / Electrical impedance tomography in patients with pulmonary arterial hypertension

Andre Luiz Dresler Hovnanian 27 November 2013 (has links)
INTRODUÇÃO: A hipertensão arterial pulmonar (HAP) é uma doença grave da circulação pulmonar, cuja adequada caracterização ainda depende do cateterismo cardíaco direito. A tomografia de impedância elétrica (TIE) é uma ferramenta de imagem não-invasiva que permite a estimativa a beira-leito da perfusão pulmonar através da medida da variação de impedância durante a sístole (deltaZQ). Embora a busca por métodos não-invasivos que possam descrever a HAP venha crescendo, dados a respeito da aplicação da TIE em pacientes com HAP permanecem escassos. OBJETIVOS: Avaliar a relação entre deltaZQ e perfil hemodinâmico, gravidade e prognóstico de pacientes com HAP. MÉTODOS: Pacientes acompanhados na Unidade de Circulação Pulmonar (InCor-HCFMUSP) e submetidos ao cateterismo cardíaco (por suspeita de HAP ou piora clínica) foram simultaneamente avaliados com a TIE. Foi possível medir deltaZQ por meio de acoplamento eletrocardiográfico. A variação de impedância relativa à ventilação (deltaZV) e a relação deltaZV/deltaZQ também foram analisadas. Com base nos resultados do cateterismo, os pacientes foram divididos em 2 grupos: HAP e aqueles com hemodinâmica normal, nomeados normopressóricos (NP). deltaZQ, deltaZV/deltaZQ e deltaZQ corrigido pelo parâmetro antropométrico peso (deltaZQ*p) foram comparados entre os grupos, correlacionados com parâmetros hemodinâmicos invasivos e analisados como preditores de mortalidade. RESULTADOS: Após o cateterismo, 35 pacientes compuseram o grupo HAP e 8 pacientes, o NP. Os pacientes com HAP apresentaram redução significativa de deltaZQ em comparação aos NP, bem como aumento na relação deltaZV/deltaZQ. Observou-se correlação entre deltaZQ e parâmetros hemodinâmicos, particularmente volume sistólico (VS) (r = 0,66, r2 = 0,43; p < 0,001). O parâmetro peso aumentou a correlação entre deltaZQ e VS (r = 0,77, r2 = 0,59; p < 0,001). Durante o período de estudo, 7 pacientes morreram; eles apresentavam perfil hemodinâmico pior, redução de deltaZQ comparados aos sobreviventes e uma desproporção ainda maior da relação deltaZV/deltaZQ. A sobrevida global em 36 meses foi de 65%. A sobrevida foi menor no grupo de pacientes com deltaZQ*p < 154,6% ou deltaZV/deltaZQ > 12. CONCLUSÕES: A medida de deltaZQ, particularmente corrigida pelo peso, está associada ao perfil hemodinâmico de pacientes com HAP, e sua redução, associada com gravidade de doença e pior prognóstico / BACKGROUND: Pulmonary arterial hypertension (PAH) is a severe disease of the pulmonary circulation, which still relies on the right heart catheterization (RHC) for its accurate characterization. Electrical impedance tomography (EIT) is a non-invasive image tool that allows the bedside estimation of lung perfusion through the measurement of impedance variation during systole (deltaZQ). Although the search for non-invasive methods for evaluation of PAH is developing, data concerning application of EIT in PAH patients remain scant. OBJECTIVES: To evaluate the relationship between deltaZQ and the hemodynamic profile, severity, and prognosis of PAH patients. METHODS: Patients followed at the Pulmonary Circulation Unit (InCor-HCFMUSP) and submitted to RHC (due to the suspicion of PAH or clinical worsening) were simultaneously evaluated by means of EIT. It was possible to measure deltaZQ by producing ECG-gated EIT images. The impedance variation related to ventilation (deltaZV) and the deltaZV/deltaZQ ratio were also analyzed. Based on the results of RHC, patients were discriminated into 2 groups: PAH and those with normal hemodynamics, referred as normo-pressoric (NP) group. deltaZQ, deltaZVdeltaZQ, and deltaZQ corrected by the anthropometric parameter weight (deltaZQ*w) were compared between groups, correlated to hemodynamic parameters, and analyzed as predictors of mortality. RESULTS: After RHC, 35 patients composed the PAH group, and 8 patients, the NP one. PAH patients showed a significant reduction of deltaZQ as compared to NP, as well as an increase of deltaZV/deltaZQ. A significant correlation between deltaZQ and hemodynamic parameters was found, particularly with stroke volume (SV) (r = 0.66, R2 = 0.43; p < 0.001). Weight correction increased the correlation between deltaZQ and SV (r = 0.77, R2 = 0.59; p < 0.001). During the study period, 7 patients died; they presented a worse hemodynamic profile, reduction of deltaZQ compared to PAH survivors, and an even higher deltaZV/deltaZQ ratio. The overall survival at 36 months was 65%. Patients with deltaZQ*w < 154.6 Kg.% or deltaZV/deltaZQ >12 presented worse survival. CONCLUSIONS: deltaZQ, particularly corrected by weight, is associated with hemodynamic status of PAH patients and its reduction is associated with disease severity and worse prognosis
66

Quantificação à beira do leito do potencial de recrutamento alveolar através da tomografia de impedância elétrica em modelo experimental síndrome do desconforto respiratório agudo / Bedside quantification of alveolar recruitment potential using electrical impedance tomography in an experimental model of acute respiratory distress syndrome

Roberta Ribeiro de Santis Santiago 19 January 2016 (has links)
Introdução: A síndrome do desconforto respiratório agudo (SDRA) tem como parte do seu tratamento uma ventilação mecânica adequada. A manobra de recrutamento alveolar (MRA) faz parte de um grupo de estratégias empregadas nos quadros moderados e graves. A MRA consiste na aplicação de um aumento de pressão transitório e controlado nas vias aéreas no intuito de abrir alvéolos previamente colapsados. A Tomografia de Impedância Elétrica (TIE) é capaz de avaliar o potencial de recrutamento alveolar (PRA) a beira leito. Objetivos:1) Comparar o PRA calculado pela TIE (através do ganho de complacência regional) com a TC. 2) Avaliar o \"deslocamento vertical de volume\" como índice de recrutamento alveolar.3) Estimar precocemente o PRA, através das manobras de recrutamento de rastreio propostas, utilizando a TIE. Método: Avaliamos o PRA em um modelo experimental de SDRA. Utilizamos 15 suínos da raça Landrace. Os animais foram sedados e intubados, em seguida, submetidos ao modelo experimental de SDRA desenvolvido na Faculdade de Medicina da Universidade de São Paulo (LIM-09). Ao término da lesão, um grupo de 7 animais recebeu uma sequência randomizada de manobras de recrutamento de rastreio propostas (Pressões inspiratórias de 30, 35 e 40 cmH2O) seguidas da manobra de recrutamento máxima (Pressão inspiratória de 60 cmH2O). Os animais foram monitorados com TIE e Tomografia computadorizada por raio X (TC) durante todas as manobras de recrutamento. Outro grupo de 8 animais ,submetidos a mesma lesão e com medidas de TC e TIE, foi retirado do banco de dados do LIM-09 e também analisados. Utilizamos o programa IBM® SPSS® Statistics 9.0 e 20.0.Resultados:1) PRA calculado pela TIE atráves do ganho de complacência regional corrigido para hiperdistensão, comparado com TC, apresentou um R2=0,76. 2) PRA calculado pelo ganho de complacência regional corrigido para hiperdistensão combinado com o deslocamento vertical apresentou R2 = 0,91 comparado a TC .3) As manobras de rastreio não conseguiram predizer quantitativamente o PRA mas auxiliariam na correção da hiperdistensão. Conclusões: A TIE é capaz de avaliar o recrutamento alveolar a beira leito. O deslocamento vertical combinado com o ganho de complacência regional corrigida para hiperdistensão representam de forma semelhante a TC o comportamento pulmonar durante uma MRA. A aplicação de uma manobra de recrutamento de rastreio pode ser útil para uma manobra de recrutamento máxima mais segura / Introduction: The acute respiratory distress syndrome (ARDS) treatment demands a proper mechanical ventilation strategy. The alveolar recruitment maneuver (ARM) is an intervention applied in moderate and severe cases of ARDS. ARM is a transitory and controlled increase in mechanical ventilator pressure delivered to the lungs aiming to open previously collapsed alveoli. The electrical impedance tomography (EIT) is a valuable tool at bedside; it is able to monitor and to help during an ARM performance through the estimation of the alveolar recruitment potential (ARP). Objectives: 1) To compare the ARP with the EIT as a regional compliance improvement quantification adjusted for lung hyperdistention with CT. 2) To evaluate the \"volume vertical displacement\" at the same pressure as alveolar recruitment index using EIT and CT. 3) To estimate earlier the ARP using the EIT through a screening recruitment maneuver. Methods: We evaluated the ARP in an experimental model of ARDS. We studied 15 Landrace race pigs. Subjects were sedated, intubated and submitted to the ARDS experimental model developed at Medical investigation laboratory n ° 09, University of São Paulo. In the end of the lung injury, a group of 7 pigs received a randomized sequence of screening recruitment maneuvers (inspiratory pressures of 30, 35 and 40 cmH2O) followed by a maximum recruitment maneuver (inspiratory pressure of 60 cmH2O).EIT and x-ray computed tomography (CT) monitored the steps of each recruitment maneuver. Another group of 8 pigs, submitted to the same lesion and with measures of EIT and CT, were extracted from our data bank. Analysis was performed at IBM® SPSS® Statistics 20.0. Results: 1) ARP calculated by EIT (regional compliance improvement quantification) reached a R2=0,76 when compared to CT. 2) The combination of regional compliance improvement and volume vertical displacement obtained R2 = 0,91 when compared to CT 3) The screening recruitment maneuvers were not able to predict quantitatively the ARP, but they helped in the lung hyperdistension adjustment. Conclusions: EIT is able to evaluate the ARP at bedside. The combination of regional compliance improvement and volume vertical displacement give information similar to CT about the lung behavior during a ARM. The application of a recruitment screening maneuver might be useful for more safe ARM
67

Efeitos interativos da pressão expiratória final positiva (PEEP) e da fração inspirada de oxigênio (FIO2) no colapso pulmonar durante anestesia geral em modelo experimental suíno / Interactive effects of positive-end expiratory pressure (PEEP) and fraction of inspired oxygen (FIO2) on pulmonary collapse during general anesthesia in experimental swine model

José Renato de Melo 25 October 2017 (has links)
INTRODUÇÃO: O desenvolvimento de colapso pulmonar (atelectasia) durante anestesia geral com ventilação mecânica é frequente, podendo determinar hipoxemia e contribuir para desenvolvimento de outras complicações pós-operatórias, como infecção e síndrome do desconforto respiratório agudo (SDRA). O uso de fração inspirada de oxigênio (FIO2) baixa e de pressão expiratória final positiva (PEEP) podem reduzir a quantidade de pulmão atelectasiado. Existem poucos dados experimentais sobre a cinética do desenvolvimento da atelectasia no intraoperatório em diferentes ajustes de FIO2 e PEEP no decorrer do tempo. A Tomografia de impedância elétrica (TIE) do tórax permite uma análise contínua e não invasiva da função pulmonar, bem como da quantificação do colapso e pode ser usada no intraoperatório. OBJETIVOS: a) avaliar, em animais com pulmões sadios durante anestesia geral, o efeito do uso de uma PEEP individualizada escolhida através da TIE (\"PEEP titulada\"), na formação de colapso; b) analisar a magnitude e a cinética de desenvolvimento do colapso pulmonar no decorrer do período de uma hora em dois valores de FIO2 (0,4 e 1) e dois valores de PEEP (3 cmH2O e valor da PEEP titulada) através da TIE e Tomografia computadorizada (TC); c) analisar mecânica, ventilação regional e aeração pela TIE e troca gasosa nos diferentes períodos do estudo. MÉTODOS: Nove animais (suínos) com pulmão normal foram submetidos à manobra de titulação da PEEP para escolha da PEEP que determina colapso pulmonar mínimo (colapso menor que 3% determinado pela TIE, denominada \"PEEP titulada\") e posteriormente ventilados com volume corrente de 6ml/Kg em quatro ajustes, em sequência randomizada, por um período de 1 hora: FIO2 0,4 e PEEP 3, FIO2 0,4 e PEEP titulada, FIO2 1 e PEEP 3 e FIO2 1 e PEEP titulada. O colapso, ventilação regional e aeração foram medidos continuamente, através da TIE assim como dados da mecânica. Mensuramos troca gasosa e aeração pulmonar pela TC em 3 momentos em cada período do estudo (baseline, 5 e 50 minutos). RESULTADOS: A PEEP titulada foi de 11,6 ±1,4 cm H2O. Houve colapso progressivo no decorrer do tempo nos 4 grupos estudados tendo sido maior na PEEP 3 que na PEEP titulada. A medida do colapso pela TIE não foi influenciada pela FIO2 utilizada, ao contrário da mensuração pela TC na qual o colapso foi maior na FIO2 de 1. Houve queda da complacência pulmonar e aumento da pressão de distensão no decorrer do tempo, maiores na PEEP 3, sem influência da FIO2. Na região dorsal, a TIE evidenciou redução da ventilação (delta Z) na PEEP 3, sem influência da FIO2, e, também, redução da aeração (mínimo Z) que foi maior na PEEP 3 e na FIO2 de 1. Houve queda da relação PaO2/FIO2 e aumento do shunt e mistura venosa na PEEP 3. Não houve alterações hemodinâmicas clinicamente relevantes durante o estudo. CONCLUSÕES: Houve colapso progressivo no decorrer do tempo, sendo maior na PEEP 3 que na PEEP titulada. O colapso aferido pela TC foi maior na FIO2 de 1 do que na 0,4 para uma mesma PEEP, diferente da TIE cuja estimativa de colapso não foi diferente. Paralelamente houve queda da complacência pulmonar, aumento da pressão de distensão e redução da ventilação dorsal, maiores na PEEP 3 e sem influência da FIO2. A queda da aeração estimada pela TIE foi maior na PEEP 3, sendo que nas duas PEEP a aeração foi menor na FIO2 de 1 / INTRODUCTION: The development of pulmonary collapse (atelectasis) during general anesthesia with mechanical ventilation is frequent, which can determine hypoxemia and contribute to the development of other postoperative complications, such as infection and acute respiratory distress syndrome (ARDS). The use of low fraction of inspired oxygen (FIO2) and positive end expiratory pressure (PEEP) may reduce the amount of collapsed lung. There are few experimental data on the kinetics of intraoperative atelectasis development in different FIO2 and PEEP adjustments over time. Electrical impedance tomography (EIT) of the thorax allows a continuous and noninvasive analysis of pulmonary function as well as the quantification of pulmonary atelectasis and can be used intraoperatively. OBJECTIVES: a) to evaluate, in animals with healthy lungs during general anesthesia, the effect of the use of an individualized PEEP chosen through EIT (titrated PEEP), in the formation of collapse; b) to analyze the magnitude and development kinetics of pulmonary collapse during the one-hour period in two values of FIO2 (0.4 and 1) and two PEEP values (3 cmH2O and titrated PEEP value) through EIT and computed tomography (CT); c) to analyze mechanics, regional ventilation and aeration by EIT and gas exchange in the different periods of the study. METHODS: Nine animals (swine) with normal lung were submitted to a PEEP titration maneuver to select PEEP that determines minimal pulmonary collapse (collapse of less than 3% determined by EIT, called \"titrated PEEP\") and then ventilated with a tidal volume of 6ml / kg in four adjustments, in a randomized sequence, for a period of 1 hour: FIO2 0.4 and PEEP 3, FIO2 0.4 and titrated PEEP, FIO2 1 and PEEP 3 and FIO2 1 and titrated PEEP. The collapse, regional ventilation and aeration were measured continuously through EIT as well as mechanics data. We also measured gas exchange and aeration by CT at 3 times in each study period (baseline, 5 e 50 minutes). RESULTS: The titrated PEEP was 11.6 ±1.4 cm H2O. There was a progressive collapse over time in the 4 groups studied, having been higher in PEEP 3 than in titrated PEEP. The measurement of EIT collapse was not influenced by the FIO2 used, as opposed to the CT measurement in which the collapse was greater in the FIO2 1. There was a decrease in pulmonary compliance and an increase in drive pressure over time, higher in PEEP 3, without influence of FIO2. In the dorsal region, EIT showed a decrease in ventilation, as measured by delta Z, in PEEP 3, with no influence of FIO2; there was also reduction of aeration, measured by the minimum Z, higher in PEEP 3 and FIO2 of 1. There was a decrease in the PaO2 / FIO2 ratio and increased in shunt and venous admixture in PEEP 3. There was no clinically relevant change in hemodynamics during the study. CONCLUSIONS: There was a greater collapse in PEEP 3 than in titrated PEEP over time. Collapse measured by CT was higher in FIO2 of 1 than 0.4 for the same PEEP, different from EIT estimates of collapse which was not different. Beside the collapse, there were decrease in compliance, increase in driving pressure and reduction of dorsal ventilation, higher in PEEP 3 without FIO2 influence. The decrease of aeration estimated by EIT was higher in PEEP 3 and for both PEEP values aeration was lower with FIO2 of 1
68

Modelagem da impedância de suspensões de células biológicas na eletropermeabilização / Modeling the electrical impedance of biological cell suspensions in the electroporation

Farias, Heric Dênis 25 September 2016 (has links)
Made available in DSpace on 2016-12-12T20:27:39Z (GMT). No. of bitstreams: 1 Heric Denis Farias.pdf: 2196819 bytes, checksum: ebe776ba26727b6ab81d9c4b1fb49e5d (MD5) Previous issue date: 2016-09-25 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The application of high electric fields on biological cells causes the formationof pores in the cell membrane, thereby causing an increase in their permeability. This phenomenon, called electropermeabilization have attracted increasing attention due to its wide application in biotechnology. Even being known for decades, the pore opening process in biological cell membranes is still not fully understood, nor was it even properly modeled. In this paper, two types of modeling are presented, which allow characterizing the electropermeabilization in biological cell suspensions. One of the methods is based on the analysis of the electrical impedance spectra of suspensions using genetic algorithm to determine parameters of a generic model dielectric dispersion. The other method uses instantaneous voltage and current values applied to a cell suspension during the electroporation experiment to determine the variation of the medium conductivity and thus, through the analytical model proposed by Ramos and colleagues (RAMOS et al., 2012), determine the cell conductivities. By modeling the impedance spectrum, it was observed the change in the dielectric dispersion of the sample due to the electropermeabilization process, in addition to obtaining the electrical conductivity and permittivity of the involved media. Using the electroporated cell model proposed by Ramos and colleagues (RAMOS et al., 2012), it was possible to determine the change of membrane conductance during the electropermeabilization. The validity of this model is assessed using finite element simulations, which showed good agreement with the analytical model used. Genetic algorithms are used in obtaining the parameters of the various models presented, showing great robustness in obtaining parameters based on the git between experimental and theoreticalcurves. / A aplicação de campos elétricos intensos em células biológicas provoca a formação de poros na membrana celular, causando assim o aumento de sua permeabilidade. Este fenômeno, denominado de eletropermeabiliza ção têm atraído cada vez mais atenção devido a sua ampla aplicação em biotecnologia. Mesmo sendo conhecido há várias décadas, o processo de abertura de poros em membranas de células biológicas ainda não é plenamente entendido e nem foi ainda corretamente modelado. Neste trabalho, apresenta-se dois tipos de modelagem que permitem a caracterização da eletropermeabilização em suspensões de células biológicas. Um dos métodos baseia-se na análise do espectro de impedância elétrica de suspensões com o uso de algoritmo genético para determinar parâmetros de um modelo genérico de dispersão dielétrica. O outro método utiliza valores instantâneos de tensão e corrente aplicados em uma suspensão de células durante um experimento de eletropermeabiliza ção para determinar a variação da condutividade do meio e com isso, através do modelo analítico proposto por Ramos e colaboradores (RAMOS et al., 2012), determinar a condutividade das células. Através da modelagem do espectro de impedância, foi possível verificar a alteração da dispersão dielétrica da amostra devido ao processo de eletropermeabiliza ção, além da obtenção das condutividades e permissividades elétricas dos meios envolvidos. Utilizando o modelo de célula eletropermeabilizada proposto por Ramos e colegas (RAMOS et al., 2012), foi possível obter a variação da condutância de membrana durante a eletropermeabilização. A validade deste modelo é avaliada utilizando simulações em elementos infinitos, as quais apresentaram grande concordância com o modelo analítico utilizado. Algoritmos genéticos são utilizados na obtenção dos parâmetros dos diversos modelos apresentados, mostrando grande robustez na obtenção de parâmetros baseada no ajuste entre curvas experimentais e teóricas.
69

Caracterização da reatividade das ligas alumínio AA2024-T3 e AA7475-T651 soldadas por fricção (FSW) / Characterization of the reactivity of aluminium alloys AA2024-T3 and AA7475-T651 welded by Friction Stir Welding (FSW)

ABREU, CAIO P. de 10 March 2017 (has links)
Submitted by Mery Piedad Zamudio Igami (mery@ipen.br) on 2017-03-10T14:37:28Z No. of bitstreams: 1 22056.pdf: 6258956 bytes, checksum: 5b6bd2c4bc8c6f66cd739d2ef10fe810 (MD5) / Made available in DSpace on 2017-03-10T14:37:28Z (GMT). No. of bitstreams: 1 22056.pdf: 6258956 bytes, checksum: 5b6bd2c4bc8c6f66cd739d2ef10fe810 (MD5) / A soldagem por fricção (Friction Stir Welding - FSW) é um processo eficiente de unir ligas de alumínio de alta resistência evitando defeitos que são usualmente criados quando técnicas convencionais de soldagem são utilizadas. A indústria aeronáutica tem mostrado grande interesse neste método de soldagem, tanto para a união de ligas similares como dissimilares. Entretanto, este processo causa modificações microestruturais dependentes das condições de tratamento térmico ou termomecânico. Contato elétrico entre zonas de microestruturas diferentes, por sua vez, pode resultar em acoplamento galvânico. No presente estudo, a soldagem por FSW foi usada para unir duas ligas de alumínio dissimilares, AA2024-T3 e AA7475-T651 e o efeito desta soldagem na resistência à corrosão das juntas soldadas e na microestrutura das ligas foi avaliada. Na investigação da resistência à corrosão foram utilizados ensaios eletroquímicos, especificamente, medidas de potencial de circuito aberto (OCP) em função do tempo de exposição ao meio corrosivo, ensaios de polarização e de espectroscopia de impedância eletroquímica, global (EIS) ou local (LEIS), em duas soluções, seja 0,1 M Na2SO4 ou 0,1 M Na2SO4 + 1 mM NaCl. Os ensaios eletroquímicos evidenciaram efeito de acoplamento galvânico nas juntas soldadas. A caracterização microestrutural foi realizada por microscopia ótica, microscopia eletrônica de varredura, microscopia eletrônica de transmissão e por calorimetria diferencial. As zonas afetadas pela solda tiveram importantes modificações na microestrutura indicadas pela precipitação e dissolução de precipitados que afetam a resistência à corrosão localizada. A resistência à corrosão intergranular e a resistência à esfoliação das juntas soldadas também foram avaliadas e comparadas com as das ligas AA2024-T3 e AA7475-T651 não soldadas. Os resultados mostraram aumento da suscetibilidade das juntas soldadas a estas formas de corrosão em comparação com as ligas não soldadas sendo observado ataque mais severo na liga AA7475-T651. A identificação das áreas anódicas e catódicas resultantes do acoplamento galvânico nas juntas soldadas foi realizada por teste que consistiu na deposição de camada de gel (ágar-ágar) com indicador universal na superfície das ligas soldadas. A liga AA2024-T3 atuou como cátodo, enquanto a AA7475-T651, como ânodo no par galvânico. Além disso, evolução de hidrogênio foi observada na região de interface entre a zona termomecanicamente afetada e a termicamente afetada da liga AA7475-T651 mostrando que reações catódicas também ocorreram localmente nesta última liga. Resultados de LEIS obtidos nas diferentes zonas das duas ligas soldadas por FSW mostraram acoplamento galvânico na interface entre elas para tempos curtos de ensaio e deslocamento da região mais ativa com o tempo de ensaio para a liga AA7475-T651, mais precisamente para a interface entre a zona termomecanicamente afetada e a térmicamente afetada desta liga. / Tese (Doutorado em Tecnologia Nuclear ) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
70

Índice de adiposidade corporal modificado para determinação de gordura corporal de adultos com obesidade mórbida / Modified Body Adiposity Index to determine body fat in morbid obese adults

Aline Biaseto Bernhard 14 January 2015 (has links)
INTRODUÇÃO: A obesidade mórbida tornou-se um importante problema de saúde pública. A medida de massa corporal não é capaz de identificar deficiências ou excessos dos diferentes componentes corporais, surgindo a necessidade de se avaliar a composição corporal. Não há consenso sobre o melhor método para esse fim em obesos mórbidos. O Índice de Adiposidade Corporal (IAC) foi proposto para ser um método simples e preciso para uma população de diversificada quantidade de gordura corporal (GC). OBJETIVO: Avaliar a eficácia do IAC em determinar GC de adultos com obesidade mórbida. MÉTODOS: O IAC foi comparado à Bioimpedância (BIA) em 240 adultos obesos mórbidos (Grupo 1= G1), uma equação específica para determinar GC em obesidade mórbida foi desenvolvida e, posteriormente, validada em outra amostra de 158 indivíduos (Grupo 2 = G2). RESULTADOS: Observou-se diferença significativa entre os dois métodos (p=0,039). A quantidade média de GC no G1 foi 52,3±6,1% segundo a BIA e 51,6±8,1% segundo o IAC, com uma diferença de 0,6±5,1% entre os métodos. Algumas variáveis, como gênero, RCQ e gravidade da obesidade confundiram o IAC. Para minimizar esses erros uma equação (Índice de Adiposidade Corporal Modificado = IACM) foi desenvolvida por meio de regressão linear (IACM% = 23,6 + 0,5 x (IAC); somar 2,2 se IMC >= 50kg/m2 e 2,4 se RCQ >= 1,05). A equação foi aplicada no G2 e possibilitou a redução da diferença entre os métodos (1,2±5,9% para 0,4±4,0%) e o fortalecimento da correlação entre eles (0,6 para 0,7). CONCLUSÕES: O IAC apresenta limitações para determinar porcentagem de gordura corporal de obesos mórbidos, já a equação sugerida (IACM) foi eficaz, não se apresentando significativamente diferente da Bioimpedância e corrigindo as limitações anteriormente apresentadas pelo IAC / BACKGROUND: Morbid obesity has become a public health problem. As body mass is not able to identify deficiencies or excesses of body components, the need to assess body composition emerged. There is no consensus of the best method to measure body composition in morbidly obese adults and a simple, accurate, reproducible and inexpensive method is desirable. The Body Adiposity Index (BAI) has been proposed to be a simple and accurate method for a population with a diverse amount of body fat (BF). OBJECTIVE: Evaluate the efficacy of BAI in determining BF of morbid obese adults. METHODS: BAI was compared to bioimpedance (BIA) in 240 morbidly obese adults (Group One= G1) and a specific equation for morbid obesity has been developed to determine BF and then validated on another sample of 158 subjects (Group Two= G2). RESULTS: There was a significant difference between the two methods (p=0,039). The average amount of BF in G1 was 52.3±6.1%, according to BIA and 51.6±8.1% according to BAI, with a difference of 0.6±5.1% between methods. Some variables, such as gender, WHR and severity of obesity mistook BAI. To minimize these errors an equation (Modified Body Adiposity Index = MBAI) was developed by linear regression (MBAI% = 23.6 + 0.5 x (BAI); add 2.2 if BMI >= 50kg/m2 and 2.4 if WHR >= 1.05). The equation was applied to G2 and resulted in a reduction in the difference between methods (1.2±5.9% to 0.4±4.12%) and strengthening of the correlation between them (0.6 to 0.7). CONCLUSIONS: BAI has limitations in determine BF in morbid obesity. The suggested equation (MBAI) was effective for predicting body fat in morbid obese adults; MBAI wasn\'t significant different from BIA and was able to correct BAI limitations

Page generated in 0.0775 seconds