• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 14
  • 7
  • Tagged with
  • 21
  • 21
  • 11
  • 10
  • 9
  • 9
  • 9
  • 6
  • 6
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Methods for Cole Parameter Estimation from Bioimpedance Spectroscopy Measurements

Ayllón, David January 2010 (has links)
No description available.
12

Development of a Software Application Suite for Electrical Bioimpedance Data Analysis

Rodríguez Portero, Alejandro January 2010 (has links)
No description available.
13

Elaboração de equações preditivas de gordura por segmento corporal e propostas de métodos objetivos para diagnóstico de lipodistrofia em pacientes soropositivos para HIV em terapia antirretroviral / Development of predictive equations of fat per body segments and proposed objective methods for diagnosis of lipodystrophy in HIV-positive patients on antiretroviral therapy

Rebeca Antunes Beraldo 26 July 2013 (has links)
Introdução: O conjunto de alterações de composição corporal e metabólicas encontrada em pacientes soropositivos para HIV é denominado de síndrome da lipodistrofia O ponto central da síndrome são as alterações da composição corporal que envolve a lipoatrofia em membros e face e/ou lipohipertrofia abdominal e dorso cervical. Até o momento, nesse grupo a determinação de gordura por segmento corporal pode ser obtida por métodos como a absorciometria dos raios X de dupla energia (DXA), mas não por medidas antropométricas e de bioimpedância elétrica (BIA), que seriam mais viáveis na prática clínica. Objetivos: Elaborar equações por regressão linear para estimativa de gordura em cada segmento (braço, perna e tronco) considerando variáveis antropométricas e de BIA segmentar e propor pontos de corte para classificar a lipodistrofia em pacientes soropositivos para HIV em terapia antirretroviral de alta potência (TARV). Métodos: Foram aferidas circunferências (braço, cintura, quadril, coxa, panturrilha), pregas cutâneas (bíceps, tríceps, subescapular, suprailíaca) e realizados exames de BIA segmentar e DXA em 100 pacientes soropositivos para HIV do sexo masculino. A partir destas variáveis foram elaboradas equações para estimativa de gordura por segmentos (braço, perna e tronco). Para propor pontos de corte foram utilizadas as curvas ROC utilizando o exame clínico para identificação da sensibilidade e especificidade. Resultados: Foram elaboradas 2 modelos para braço e tronco utilizando apenas medidas antropométricas e 2 modelos para a perna utilizando variáveis de BIA e antropométricas. Os coeficientes de determinações para os modelos de braço, tronco, pernas foram: 0.66 e 0.66; 0.76 e 0.75; 0.5 e 0.45, respectivamente. As razões propostas foram: circunferência da cintura pela circunferência da coxa (CC/CCo), circunferência da cintura pela da panturrilha (CC/CPant) e razão tronco braço (RTB). Os melhores pontos de corte observados para CC/CCo, RTB e para o índice já proposto na literatura fat mass ratio (FMR) foram de 1,74; 2,08 e 1,26, respectivamente. Conclusões: As equações e razões antropométricas podem ser utilizados para auxiliar no diagnóstico de lipodistrofia com a finalidade de contribuir para um diagnóstico mais acurado e precoce possibilitando intervenções e até prevenindo maiores alterações da composição corporal. / Background: The changes in body composition and metabolic parameters, found in HIV seropositive is called lipodystrophy syndrome. The central point of the syndrome are changes in body composition that involves the face and limb lipoatrophy and / or abdominal back neck lipohypertrophy. Until now, in this group of individual, the determination of fat per body segment can be obtained by methods such as X-ray absorptiometry dual energy absorptiometry (DXA), but not by anthropometric measurements and bioelectrical impedance analysis (BIA), which would be more feasible in practice clinic. Objectives: Develop equations, using linear regression, to estimate fat in each segment (arm, leg and trunk) considering anthropometric variables and segmental BIA and propose cutoff points for classifying lipodystrophy in HIV seropositive patients on highly active antiretroviral therapy (HAART). Methods: We measured circumferences (arm, waist, hip, thigh, calf), skinfolds (biceps, triceps, subscapular, suprailiac) and conducted examinations of segmental BIA and DXA in 100 HIV seropositive men. From these variables were developed equations to estimate fat segments (arm, leg and trunk). To propose cutoffs were used ROC curves using clinical examination to identify the sensitivity and specificity. Results: We developed two models for arm and trunk using only anthropometric measurements and two models for leg using BIA and anthropometric variables. The coefficients of determination for models of arm, trunk and leg were 0.66 and 0.66, 0.76 and 0.75, 0.5 and 0.45, respectively. The proposed reasons were: waist circumference by the circumference of the thigh (WC / CTh), waist circumference by the calf (WC / Cca) and trunk arm ratio (TAR). The best cutoff points observed for WC/CTh , TAR and the index already proposed in the literature fat mass ratio (FMR) were 1.74, 2.08 and 1.26, respectively. Conclusions: The anthropometric reasons and the equations can be used to aid in the diagnosis of lipodystrophy in order to contribute to a more accurate diagnosis and early intervention and to prevent possible major changes in body composition.
14

ELECTRICAL BIOIMPEDANCE CEREBRAL MONITORING : A Study of Cerebral Impedance Variation / ÖVERVAKNING AV HJÄRNAN MED ELEKTRISK BIOIMPEDANS : En Studie om Cerebrala Impedansändringar

Mokhberi, Shiva January 2016 (has links)
Stroke is amongst the leading causes of death and disability worldwide. Today diagnosis of Stroke is restricted to fixed imaging facilities which do not provide a rapid diagnostic. A portable device which could provide a non invasive assessment of stroke would therefore decrease the time of diagnosis and increase the chance of survival. Recent studies have confirmed that Implementing Electrical Bioimpedance in a portable device could provide a reliable means for Stroke diagnostic. However in order to be able to use the brain impedance as an indicator of Stroke, the invariance of brain impedance with time in healthy individuals should be studied first. Experimental Bioimpedance Spectroscopy (BIS) measurements from a healthy control group of 10 subjects have been used in this study to inspect the variation of brain impedance in the span of two weeks. The results of this study suggest that the cap which was used for brain impedance measurements together with  the available device have not been an optimal way of measuring the brain impedance and therefore have affected the data by causing artifacts for the results. With the artifacts available in the data acquired in this study it is not possible to make any statements about the variation of brain impedance and therefore a deeper analysis of collected data using descriptive analysis is required in order to be able to judge on the significance of the obtained errors. In the future a larger study group should be considered in order to increase the predictive power of the observations. / Stroke är bland de ledande orsakerna till död och funktionshinder i  hela världen.I dagsläget är diagnos av stroke begränsad till fasta bildenheter som inte möjliggör en snabb diagnos. En bärbar enhet som möjliggör en icke invasiv bedömning av sjukdomen skulle minska diagnos tiden och följaktligen öka chansen att överleva sjukdomen. Genomförda studier i ämnet har bekräftat att implementering av  Electrical Bioimpedance i en bärbar enhet kan räknas som ett effektivt sätt för Stroke diagnostik. För att kunna använda hjärnans impedans för Stroke diagnostik, bör först en studie av hjärnans impedans på friska individer utföras för att kunna visa att impedansen är oförändrad med tiden. Experimentell Bioimpedans Spektroskopi (BIS) mätningar från en frisk kontrollgrupp av 10 försökspersoner har utförts i denna studie för att inspektera variationen av hjärnans impedans under två veckor. Resultaten från denna studie tyder på att sättet av impedans mätningen i dagsläget är inte optimalt. Artefakter presenterad i resultatet gör det omöjligt för att kunna komma till ett beslut om hjärnans impedans variation . För fortsätta studier bör man överväga en större kontrollgrupp och även en analysering av data med hjälp av t-statistik som var inte inom ramen av denna studie.
15

Implementation of and Electrical Bioimpedance Measurement System for Renal Function Monitoring

Pérez-Vázquez Losada, Sonia January 2008 (has links)
Peritoneal Dialysis is a treatment for patients suffering from renal failure thatallows out-patient care. This means that the patient only needs to visit the hospital forconsultation and not for treatment, increasing considerably the comfort of the patient,while reducing remarkably the cost per patient.In order to increase the level of medical supervision obtained with the periodicvisits to the clinic, televisit has been put into practice in some hospitals. But thesetelevisits are based on indirect and qualitative indicators of renal failure, and thereforethey are just valid for detection of situations near limit cases, such as well over-hydratedor dehydrated.Electrical Bioimpedance Measurements have been proved to constitute anappropriate method for assessment of body composition, and therefore they can providewith direct indicators of body fluid distribution. Such ability of EBI technology allowsthe detection of body fluid unbalance caused by renal dysfunction, and therefore,nephrology televisits would benefit tremendously from EBI measurements.This project is based on the AD5933 Impedance Network Analyzer of AnalogDevices, and the main task is to develop a software application that controls theevaluation board in which it is implemented, and allows the storage of the EBImeasurements in EDF+ files that will facilitate the management of medical data whenapplied to televisit. These files are uploaded to XML format in order to be sent to aremote server, where a software application will have been implemented for medicalconsultation. / Uppsatsnivå: D
16

Desenvolvimento de um sistema de bioimpedância elétrica baseado em FPGA / Development of bioimpedance system based on FPGA

Veiga, Emiliano Amarante 02 August 2013 (has links)
Made available in DSpace on 2016-12-12T20:27:37Z (GMT). No. of bitstreams: 1 Resumo - Emiliano.pdf: 94943 bytes, checksum: 29697d95e7130478be8d1ad382dffdeb (MD5) Previous issue date: 2013-08-02 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Electrical Impedance Spectroscopy (EIS), also called Bioelectrical Impedance Analysis (BIA), is a non-invasive technique used for characterizing the electrical properties of biological materials, but also used for obtaining body composition properties and for analyzing food quality. Most EIS devices contain microcontrollers, digital signal generators and data acquisition boards. Digital Signal Processors (DSP) have also been used to implement EIS systems, but they su_er for multifrequency signal generation. Furthermore, DSPs do not have enough space for data storage. On the other hand, EIS systems based on Field-Programmable Gate Array (FPGA) devices are indicated when signal generation and acquisition demand integration and a very small noise level. In addition, FPGA can be used for getting real time signal processing, as it is a hardware rather than sequential execution of instructions. The bioimpedance measurements consist of injecting a sinewave into the material under study by two electrodes and measuring the resulting voltage by other pair of electrodes, which are placed in an impedance probe. Most EIS systems measure the injecting current by a shunt resistor, and then the real and imaginary part of the impedance of the load under study are calculated for each discrete frequency of the system. In this work, an EIS system is proposed based on FPGA for generating sinusoidal signals in the frequency range 0.1 to 500 kHz. It contains two acquisition channels and an interface for measuring both the modulus and phase of the impedance. A proposed EIS system is fully described. The system performance of the FPGA and the acquisition interface were comprehensively investigated. Experiments using saline solutions were used in order to calibrate the impedance probe used in this work. Measurements in raw bovine milk were made in order to validate the proposed EIS system. The results showed an error of 2% when measuring milk samples in the conductivity range of 1.46 to 2.9 mS/cm. Further measurements were made in order to investigate the e_ects in the impedance spectra due to Somatic Cell Count (SCC) and hydrogen peroxide in the bovine milk. The results showed that the impedance phase spectra are sensitive to SCC at low frequencies. It has also been shown that the impedance phase of the milk adulterated with hydrogen peroxide is almost linear in the frequency range from 1 up to 10 kHz. It was showed that real time measurements and signal processing based on FPGA can be used for developing an EIS system. The proposed system is modular and it can be portable. This might be the case of using this system for measuring and characterizing bovine milk by hand-held or in-milkline instrumentation. / Espectroscopia de Impedância Elétrica (EIE), também conhecida como Análise por Bioimpedância Elétrica, é uma técnica não-invasiva utilizada para determinação das propriedades elétricas de materiais biológicos e também empregada para obtenção da composição corporal e estudo da qualidade de alimentos. Diversos sistemas de EIE são projetados com microcontroladores, sintetizadores de sinais digitais e placas de aquisição. Processadores Digitais de Sinais (DSP) também são utilizados para projetos de sistemas de EIE, porém, eles sofrem falta de recursos para trabalhar com geração e condicionamento de sinais multifrequenciais. Além do mais, não têm espaço de memória su_ciente para o armazenamento de dados. Por outro lado, os sistemas baseados em FPGA são indicados para aplicações que envolvem geração e aquisição de sinais multifrequenciais que exigem forte integração e redução de ruídos na eletrônica. Diferente da execução sequencial de instruções, o FPGA trabalha em tempo real, já que se trata de processamento em hardware. A medição de bioimpedância consiste em injetar uma onda senoidal no material em estudo por meio de dois eletrodos e medir a tensão resultante através de outro par de eletrodos, onde estão fixados em uma sonda de impedância. A maioria dos sistemas de EIE efetuam a medição da corrente usando uma carga de teste e em seguida executam o cálculo da parte real e imaginária da impedância para cada frequência. Neste trabalho, é proposto um sistema de EIE baseado em FPGA para gerar sinais senoidais na faixa de frequência de 0,1 a 500 kHz. É composto de dois canais de aquisição e uma interface para medição de módulo e fase da impedância. Sua arquitetura detalhada está descrita nas seções seguintes, onde o desempenho da geração e aquisição de sinais foram precisamente estudados. Experimentos com soluções salinas foram realizados para calibrar o sistema, e medições com leite bovino foram efetuadas para validação do sistema proposto. Os resultados indicam um erro de 2% na medição de amostras com condutividade entre 1,46 e 2,9 mS/cm. Outras medições foram realizadas para investigar os efeitos no espectro de impedância devido a Contagem de Células Somáticas (CCS) e peróxido de hidrogênio no leite bovino e os estudos mostraram que o espectro de fase é sensível a CCS em baixas freqüências. Também foi possível veri_car que o leite adulterado com peróxido de hidrogênio apresenta fase aproximada a linear na faixa de 1 a 10 kHz. Este trabalho mostrou que a medição em tempo real com arquitetura baseada em FPGA pode ser utilizada para projetar sistemas de EIE. O sistema proposto é modular e pode ser portável, permitindo sua utilização para medição e caracterização do leite bovino inloco manualmente ou por instrumentação usando recipiente com amostra de leite.
17

Modular textile-enabled bioimpedance system for personalized health monitoring applications

Ferreira, Javier January 2017 (has links)
A growing number of factors, including costs, technological advancements, ageing populations, and medical errors, are leading industrialized countries to invest in research on alternative solutions to improve their health-care systems and increase patients’ quality of life. Personal health systems (PHS) examplify the use of information and communication technologies that enable a paradigm shift from the traditional hospital-centered healthcare delivery model toward a preventive and person-centered approach. PHS offer the means to monitor a patient’s health using wearable, portable or implantable systems that offer ubiquitous, unobtrusive biodata acquisition, allowing remote monitoring of treatment and access to the patient’s status. Electrical bioimpedance (EBI) technology is non-invasive, quick and relatively affordable technique that can be used for assessing and monitoring different health conditions, e.g., body composition assessments for nutrition. When combined with state-of-the-art advances in sensors and textiles, EBI technologies are fostering the implementation of wearable bioimpedance monitors that use functional garments for personalized healthcare applications. This research work is focused on the development of wearable EBI-based monitoring systems for ubiquitous health monitoring applications. The monitoring systems are built upon portable monitoring instrumentation and custom-made textile electrode garments. Portable EBI-based monitors have been developed using the latest material technology and advances in system-on-chip technology. For instance, a portable EBI spectrometer has been validated against a commercial spectrometer for total body composition assessment using functional textile electrode garments. The development of wearable EBI-based monitoring units using functional garments and dry textile electrodes for body composition assessment and respiratory monitoring has been shown to be a feasible approach. The availability of these measurement systems indicates progress toward the real implementation of personalized healthcare systems. / <p>QC 20170517</p>
18

Composição corporal em pacientes com doença inflamatória intestinal: antropometria versus bioimpedância / Body composition of patients with inflamatory bowel disease: antropometry versus bioimpedance

Viviane Abrantes Jardim 25 March 2013 (has links)
A Doença Inflamatória Intestinal (DII) é uma desordem caracterizada pela inflamação difusa do trato gastrointestinal. Os dois principais tipos de DII são a Retocolite Ulcerativa (RCU) e a Doença de Crohn (DC) e ambas cursam com alterações no estado nutricional (EN). O objetivo deste estudo foi comparar a composição corporal, obtida por meio de diferentes métodos, em pacientes com DC e RCU em atendimento ambulatorial, avaliando possíveis diferenças nos grupos de doentes entre si e quando comparados a indivíduos saudáveis. Foi realizado um estudo transversal incluindo 101 pacientes com DII, sendo 50 com DC (GDC) e 51 com RCU (GRCU), além de 35 indivíduos saudáveis (GCON), selecionados no Ambulatório do Hospital Universitário Pedro Ernesto (HUPE) da Universidade do Estado do Rio de Janeiro (UERJ). Informações sócio-demográficas e pessoais, como prática de exercício físico, tabagismo, doenças pregressas e procedimentos cirúrgicos prévios foram coletadas. A avaliação antropométrica consistiu de: peso; altura; circunferências do braço, da cintura e do quadril; circunferência muscular do braço (CMB) e pregas cutâneas do tríceps, bíceps, peitoral, axilar, subescapular, suprailíaca, supraespinhal, abdominal, perna e coxa. O percentual de gordura corporal (% GC) foi estimado a partir de equações que utilizam o somatório de pregas cutâneas e por meio de bioimpedância elétrica (BIA). Para estimar o percentual de gordura subcutânea foi utilizado o somatório de dez dobras. As variáveis laboratoriais analisadas foram: hemograma completo, proteínas totais, albumina, globulina, velocidade de hemossedimentação e proteína C reativa. As análises estatísticas foram realizadas utilizando-se o software STATA versão 10.0. A classificação do EN, por meio do índice de massa corporal (IMC), evidenciou baixa prevalência de desnutrição nos três grupos avaliados. Ao analisar diretamente as medidas antropométricas de peso e IMC, observou-se que os pacientes com DC apresentaram valores significativamente menores do que os indivíduos do grupo controle. A avaliação da CMB mostrou que os pacientes do GDC e GRCU apresentaram depleção de massa magra em comparação aos indivíduos do GCON, porém sem apresentar diferenças entre os dois grupos de pacientes com DII. Em relação ao %GC obtido por BIA não foram verificadas diferenças entre os três grupos de estudo. Ao se verificar o %GC com a utilização das fórmulas de Peterson, Durnin & Womersley e Jackson & Pollock (que utiliza o somatório de três dobras) observou-se que os pacientes com DC apresentaram tecido adiposo significativamente depletado em relação aos indivíduos do GCON e do GRCU. Ao compararmos os %GC obtidos por diferentes métodos de estimativa, observou-se que as equações de Jackson & Pollock (que utilizam o somatório de três e sete dobras) apresentaram resultados significativamente menores quando comparados aos das equações de Peterson e Durnin & Womersley, nos dois grupos de pacientes. Os níveis séricos de proteínas totais e albumina, e a contagem total de hemácias foram menores nos indivíduos com DC quando comparados aos indivíduos do grupo controle e/ou aos indivíduos do grupo com RCU. Os pacientes com DC apresentaram comprometimento importante do EN em comparação aos pacientes com RCU e, notadamente, em relação aos indivíduos saudáveis. / Inflammatory Bowel Disease (IBD) is a disorder characterized by diffuse inflammation of the gastrointestinal tract. The two main types of IBD are ulcerative colitis (UC) and Crohn's disease (CD), both coursing with changes in nutritional status (NS). The objective of this study was to investigate the existence of associations between body composition measured by electrical bioimpedance (BIA) and by the equations used for the estimate of fat percent in patients with CD and UC on ambulatory treatment and when compared to healthy individuals. A cross-sectional study was conducted on 101 patients with IBD, 50 of them with CD (GCD) and 51 with UC (GUC), and on 35 healthy subjects (GCON), selected at the Ambulatory of Pedro Ernesto University Hospital (HUPE) of the Rio de Janeiro State University (UERJ). Sociodemographic information such as practice of physical activity, smoking habit, previous diseases and surgical procedures was collected. Anthropometric evaluation consisted of weight; height; arm, waist and hip circumferences; arm muscle circumference (AMC), and the following skin folds: triceps, biceps, pectoral, axillary, subscapular, suprailiac, supraspinal, abdominal, leg, and thigh. Percent body fat (%BF) was estimated using equations based on the sum of skin folds and by BIA. Percent subcutaneous fat was estimated as the sum of ten folds. The laboratory variables analyzed, included: complete blood count, total protein, albumin, globulin, erythrocyte sedimentation rate, and C-reactive protein. Data were analyzed statistically using the STATA software, version 10.0. Classification of NS based on body mass index (BMI) revealed a low prevalence of malnutrition in the groups evaluated. Direct analysis of weight and BMI measurements revealed that patients with CD had significantly lower values than GCON individuals. The evaluation of AMC showed that GCD and GUC patients had depleted lean mass compared to GCON individuals, with no difference between the two groups of patients with IBD. No differences in %BF determined by BIA were detected among the three study groups. When %BF was determined using the formulas of Peterson, Durnin & Womersley and Jackson & Pollock (which use the sum of three folds), patients with CD were found to have significantly depleted adipose tissue compared to GCON and GUC individuals. Comparison of %BF values obtained by different estimate methods showed that the equations of Jackson & Pollock (which use the sum of three and seven folds) yielded significantly lower results than the equations of Peterson and Durnin & Womersley for the two patient groups. Seric levels of total protein and albumin, as well as red blood cell count and relative count of lymphocytes were lower in the individuals with CD than the individuals of the control group and/or the patients with UC. Patients with CD showed significant involvement of NS compared to patients with UC and especially compared to healthy individuals.
19

Composição corporal em pacientes com doença inflamatória intestinal: antropometria versus bioimpedância / Body composition of patients with inflamatory bowel disease: antropometry versus bioimpedance

Viviane Abrantes Jardim 25 March 2013 (has links)
A Doença Inflamatória Intestinal (DII) é uma desordem caracterizada pela inflamação difusa do trato gastrointestinal. Os dois principais tipos de DII são a Retocolite Ulcerativa (RCU) e a Doença de Crohn (DC) e ambas cursam com alterações no estado nutricional (EN). O objetivo deste estudo foi comparar a composição corporal, obtida por meio de diferentes métodos, em pacientes com DC e RCU em atendimento ambulatorial, avaliando possíveis diferenças nos grupos de doentes entre si e quando comparados a indivíduos saudáveis. Foi realizado um estudo transversal incluindo 101 pacientes com DII, sendo 50 com DC (GDC) e 51 com RCU (GRCU), além de 35 indivíduos saudáveis (GCON), selecionados no Ambulatório do Hospital Universitário Pedro Ernesto (HUPE) da Universidade do Estado do Rio de Janeiro (UERJ). Informações sócio-demográficas e pessoais, como prática de exercício físico, tabagismo, doenças pregressas e procedimentos cirúrgicos prévios foram coletadas. A avaliação antropométrica consistiu de: peso; altura; circunferências do braço, da cintura e do quadril; circunferência muscular do braço (CMB) e pregas cutâneas do tríceps, bíceps, peitoral, axilar, subescapular, suprailíaca, supraespinhal, abdominal, perna e coxa. O percentual de gordura corporal (% GC) foi estimado a partir de equações que utilizam o somatório de pregas cutâneas e por meio de bioimpedância elétrica (BIA). Para estimar o percentual de gordura subcutânea foi utilizado o somatório de dez dobras. As variáveis laboratoriais analisadas foram: hemograma completo, proteínas totais, albumina, globulina, velocidade de hemossedimentação e proteína C reativa. As análises estatísticas foram realizadas utilizando-se o software STATA versão 10.0. A classificação do EN, por meio do índice de massa corporal (IMC), evidenciou baixa prevalência de desnutrição nos três grupos avaliados. Ao analisar diretamente as medidas antropométricas de peso e IMC, observou-se que os pacientes com DC apresentaram valores significativamente menores do que os indivíduos do grupo controle. A avaliação da CMB mostrou que os pacientes do GDC e GRCU apresentaram depleção de massa magra em comparação aos indivíduos do GCON, porém sem apresentar diferenças entre os dois grupos de pacientes com DII. Em relação ao %GC obtido por BIA não foram verificadas diferenças entre os três grupos de estudo. Ao se verificar o %GC com a utilização das fórmulas de Peterson, Durnin & Womersley e Jackson & Pollock (que utiliza o somatório de três dobras) observou-se que os pacientes com DC apresentaram tecido adiposo significativamente depletado em relação aos indivíduos do GCON e do GRCU. Ao compararmos os %GC obtidos por diferentes métodos de estimativa, observou-se que as equações de Jackson & Pollock (que utilizam o somatório de três e sete dobras) apresentaram resultados significativamente menores quando comparados aos das equações de Peterson e Durnin & Womersley, nos dois grupos de pacientes. Os níveis séricos de proteínas totais e albumina, e a contagem total de hemácias foram menores nos indivíduos com DC quando comparados aos indivíduos do grupo controle e/ou aos indivíduos do grupo com RCU. Os pacientes com DC apresentaram comprometimento importante do EN em comparação aos pacientes com RCU e, notadamente, em relação aos indivíduos saudáveis. / Inflammatory Bowel Disease (IBD) is a disorder characterized by diffuse inflammation of the gastrointestinal tract. The two main types of IBD are ulcerative colitis (UC) and Crohn's disease (CD), both coursing with changes in nutritional status (NS). The objective of this study was to investigate the existence of associations between body composition measured by electrical bioimpedance (BIA) and by the equations used for the estimate of fat percent in patients with CD and UC on ambulatory treatment and when compared to healthy individuals. A cross-sectional study was conducted on 101 patients with IBD, 50 of them with CD (GCD) and 51 with UC (GUC), and on 35 healthy subjects (GCON), selected at the Ambulatory of Pedro Ernesto University Hospital (HUPE) of the Rio de Janeiro State University (UERJ). Sociodemographic information such as practice of physical activity, smoking habit, previous diseases and surgical procedures was collected. Anthropometric evaluation consisted of weight; height; arm, waist and hip circumferences; arm muscle circumference (AMC), and the following skin folds: triceps, biceps, pectoral, axillary, subscapular, suprailiac, supraspinal, abdominal, leg, and thigh. Percent body fat (%BF) was estimated using equations based on the sum of skin folds and by BIA. Percent subcutaneous fat was estimated as the sum of ten folds. The laboratory variables analyzed, included: complete blood count, total protein, albumin, globulin, erythrocyte sedimentation rate, and C-reactive protein. Data were analyzed statistically using the STATA software, version 10.0. Classification of NS based on body mass index (BMI) revealed a low prevalence of malnutrition in the groups evaluated. Direct analysis of weight and BMI measurements revealed that patients with CD had significantly lower values than GCON individuals. The evaluation of AMC showed that GCD and GUC patients had depleted lean mass compared to GCON individuals, with no difference between the two groups of patients with IBD. No differences in %BF determined by BIA were detected among the three study groups. When %BF was determined using the formulas of Peterson, Durnin & Womersley and Jackson & Pollock (which use the sum of three folds), patients with CD were found to have significantly depleted adipose tissue compared to GCON and GUC individuals. Comparison of %BF values obtained by different estimate methods showed that the equations of Jackson & Pollock (which use the sum of three and seven folds) yielded significantly lower results than the equations of Peterson and Durnin & Womersley for the two patient groups. Seric levels of total protein and albumin, as well as red blood cell count and relative count of lymphocytes were lower in the individuals with CD than the individuals of the control group and/or the patients with UC. Patients with CD showed significant involvement of NS compared to patients with UC and especially compared to healthy individuals.
20

Projeto de circuito oscilador controlado numericamente implementado em CMOS com otimização de área. / Design of a circuit numerically controlled oscilator implemented in CMOS with area optimization.

Carvalho, Paulo Roberto Bueno de 25 October 2016 (has links)
Este trabalho consiste no projeto e implementação em CMOS de um circuito integrado digital para geração de sinais, denominado Oscilador Controlado Numericamente. O circuito será aplicado em um sistema de Espectroscopia por Bioimpedância Elétrica, utilizado como método para detecção precoce de câncer do colo do útero. Durante o trabalho, realizou-se o estudo dos requisitos do sistema de espectroscopia e as especificações dos tipos de sinais a serem gerados. Levantou-se, na bibliografia, algumas técnicas de codificação em linguagem de hardware para otimização do projeto nos quesitos área, potência dissipada e frequência máxima de funcionamento. Para implementar o circuito, também se pesquisou o fluxo de projeto de circuitos digitais, focando as etapas de codificação em linguagem de descrição de hardware Verilog e os resultados de síntese lógica e de layout. Foram avaliadas duas arquiteturas, empregando-se algumas das técnicas de codificação levantadas durante o estudo bibliográfico. Estas arquiteturas foram implementadas, verificadas em plataforma programável, sintetizadas e mapeadas em portas lógicas no processo TSMC 180 nm, onde foram comparados os resultados de área e dissipação de potência. Observou-se, nos resultados de síntese lógica, redução de área de 78% e redução de 83% na dissipação de potência total no circuito em que se aplicou uma das técnicas de otimização em comparação com o circuito implementado sem otimização, utilizando uma arquitetura CORDIC do tipo unrolled. A arquitetura com menor área utilizada - 0,017 mm2 - foi escolhida para fabricação em processo mapeado. Após fabricação e encapsulamento do circuito, o chip foi montado em uma placa de testes desenvolvida para avaliar os resultados qualitativos. Os resultados dos testes foram analisados e comparados aos obtidos em simulação, comprovando-se o funcionamento do circuito. Observou-se uma variação máxima de 0,00623% entre o valor da frequência do sinal de saída obtido nas simulações e o do circuito fabricado. / The aim of this work is the design of a digital integrated circuit for signal generation called Numerically Controlled Oscillator, designed in 180 nm CMOS technology. The application target is for Electrical Bioimpedance Spectroscopy system, and can be used as a method for early detection of cervical cancer. Throughout the work, the spectroscopy system requirements and specifications of the types of signals to be generated were studied. Furthermore, the research of some coding techniques in hardware language for design optimization in terms of area, power consumption and frequency operation was conducted looking into the bibliography. The digital design flow was studied focusing on the Verilog hardware description language and the results of logic synthesis and layout, in order to implement the circuit. Reviews of two architectures have been made, using some of the encoding techniques that have been raised during the bibliographical study. These architectures have been implemented, verified on programmable platform, synthesized and mapped to standard cells in TSMC 180 nm process, which compared the area and total power consumption of results. Based on the results of logic synthesis, a 78% area reduction and 83% power consumption reduction were obtained on the implemented circuit with encoding techniques for optimization in comparison with the another circuit using a CORDIC unrolled architecture. The architecture with smaller area - 0.017 mm2 - was chosen for implementation in the mapped process. After the circuit fabrication and packaging, the chip was mounted on an evaluation board designed to evaluate the functionality. The test results were analyzed and compared with the simulation results, showing that the circuit works as expected. The output signals were compared between theoretical and experimental results, showing a maximum deviation of 0.00623%.

Page generated in 0.1242 seconds