• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 569
  • 15
  • 15
  • 14
  • 14
  • 10
  • 7
  • 3
  • 3
  • 3
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 582
  • 582
  • 576
  • 291
  • 283
  • 269
  • 66
  • 66
  • 63
  • 63
  • 57
  • 55
  • 51
  • 51
  • 50
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
371

Efeito das pastilhas higienizadoras efervescentes à base de peróxido alcalino em liga metálica de cobalto-cromo / Effect of alkaline peroxide-effervescent tablets on the surfaces of the cobalt-chromium alloys

Vasconcelos, Glenda Lara Lopes 17 December 2015 (has links)
A higienização das próteses é de fundamental importância para a longevidade do tratamento reabilitador. Entretanto, é necessário analisar os efeitos que os higienizadores podem causar nas superfícies que compõem uma prótese. Deste modo, o objetivo deste estudo foi avaliar os efeitos de pastilhas efervescentes à base de peróxido alcalino em liga de cobalto cromo (Co-Cr), utilizada em Prótese Parcial Removível (PPR). A partir de uma matriz metálica, padrões de cera em forma de disco (12 mm x 3 mm) foram confeccionados para posterior fundição. Os espécimes metálicos (n=16) foram imersos nas soluções: água deionizada (controle), Polident 3 minutes®, Steradent®, Efferdent®, Polident for Partials® e Corega Tabs®. Foi realizada a análise da rugosidade (n=10) por meio de rugosímetro, antes (t0) e após 5 períodos de simulação de ½, 1, 2, 3, 4 e 5 anos de imersão nos higienizadores. Foram realizadas análises complementares quantitativas da liberação de íons (n=5) de cobalto (Co), cromo (Cr) e molibdênio (Mo) em cada solução e análises qualitativas em um espécime de cada grupo, por meio de Microscopia Eletrônica de Varredura (MEV) e Espectrometria de Energia Dispersiva de Raios X (EDS). A distribuição dos dados de rugosidade (μm) apresentou-se não normal. Foi utilizada estatística não-paramétrica (α=0,05). Tanto para o fator solução (Kruskall Wallis, ½ ano (p=0,900), 1 ano (p=0,277), 2 anos (p=0,227), 3 anos (p=0,086), 4 anos (p=0,657) e 5 anos (p=0,856), como para o fator tempo (Friedman, p=0,137) não houve diferença significante. Com relação à liberação de íons (μg/L), a distribuição dos dados apresentou-se normal. De acordo com a estatística (α=0,05, ANOVA e teste de Tukey), Corega Tabs®, Efferdent® e água deionizada promoveram maior liberação de íons Co do que o Steradent® (p=0,003). Quanto aos íons Cr (p=0,000), Corega Tabs® propiciou maior liberação quando comparado a água deionizada, Steradent® e Polident 3 minutes®. Em relação aos íons Mo (p=0,001), o Efferdent® promoveu maior liberação. No MEV pode-se verificar que as soluções não apresentaram efeitos deletérios sobre as superfícies. Conclui-se que todas as pastilhas avaliadas não ocasionaram danos, entretanto, Steradent® foi a que propiciou menor liberação de íons, sendo indicada com maior segurança para higienização de superfícies metálicas de PPR. / The hygiene care of the removable dentures is of most importance for the longevity of the rehabilitation treatment. However, it is necessary to analyze the effects that denture cleansers can cause on the surfaces of prosthesis. Thus, the aim of this study was to evaluate the effect of alkaline peroxide-effervescent tablets on the surfaces of the cobalt-chromium alloys (Co-Cr), used in removable partial dentures (RPD). Circular specimens (12 mm x 3 mm) were fabricated with cobalt-chromium alloys. The specimens (n= 16) were immersed in the following solutions: deionized water (control), Polident 3 minutes™, Steradent™, Efferdent™, Polident for Partials™ and Corega Tabs™. The surface roughness (n=10) was analyzed with a surf-test analyzer, before and after 5 periods that corresponds to the simulation of ½, 1, 2, 3, 4 and 5 years of immersion in the cleansers. As complementary analysis, it was performed a quantitative study of ions release (n=5) for cobalt (Co), chromium (Cr) and molybdenum (Mo) in each solution and qualitative analysis with scanning electron microscopy (SEM) associated to Energy-dispersive X-ray spectroscopy (EDS). The results of surface roughness had presented no normal. In nonparametric statistics (α = 0.05), both of the solution factor Kruskall Wallis, ½ year (p=0.900), 1 year (p=0.277), 2 years (p=0.227), 3 years (p=0.086), 4 years (p=0.657) and 5 years (p=0.856), such as time factor (Friedman, p = 0.137), there was no significant difference. The results of ionic release presented a normal distribution and they were submitted to ANOVA (p=0.05) and Tukey test. The solutions Corega Tabs®, Efferdent® and deionized water presented greater Co ionic release than Steradent® (p=0.003). For Cr ions (p=0.000), Corega Tabs® had greater ionic release than deionized water, Steradent® and Polident 3 minutes®. Regarding Mo ions (p=0.001), Efferdent® showed greater release. With SEM, it was possible to verify that the solutions showed no deleterious effects on the specimen surfaces. It was concluded that no deleterious effects on metal surface was caused, however, Steradent® presented the smallest ionic release, and can be indicated more safely for cleaning metal surfaces of RPD.
372

Análise morfológica da dentina irradiada pelo laser de Er:YAG (SSP) com diferentes larguras de pulso / Effect of Er:YAG (SSP) laser pulse widths on dentin - morphological analysis

Trevelin, Lívia Tosi 30 January 2015 (has links)
Este estudo se propôs a analisar as características morfológicas da dentina humana irradiada com laser de Er:YAG utilizando diferentes larguras temporal de pulso nos protocolos de preparo cavitário e pré-tratamento da dentina. Foram utilizados 18 molares humanos que foram seccionados no sentido mésio-distal e amelocementário obtendo-se um disco plano de dentina. Em seguida foram lixados com uma sequência decrescentes de lixas para padronizar os espécimes em 2mm de espessura. Os grupos experimentais foram compostos a partir de 2 fatores de variação: 1) indicação clínica - preparo cavitário (E=200mJ/20Hz), e pré-tratamento (E=80mJ/2Hz); e 2) largura temporal de pulso - 50, 300 e 600µs. Assim formaram-se 6 grupos experimentais com (n=3): G1(E=200mJ/20Hz/50µs); G2(E=200mJ/20Hz/300µs); G3(E=200mJ/20Hz/600µs); G4(E=80mJ/2Hz/50µs); G5(E=80mJ/2Hz/300µs); G6(E=80mJ/2Hz/600µs). Os espécimes foram irradiados com o laser de Er:YAG com comprimento de onda de 2,94µm, de modo não contato, com um distância de 7mm do feixe de saída, sob irrigação de 60ml/min de água e 40ml/min de ar. Após a irradiação, os espécimes foram processados e destinados à avaliação descritiva das imagens obtidas em Microscopia Eletrônica de Varredura (MEV), nos diferentes grupos experimentais. A análise morfológica dos grupos irradiados revelou uma superfície irregular, ausência de smear layer que expõe a abertura dos túbulos dentinários, dentina peritubular evidente e, sem indícios de carbonização e derretimento para todos os protocolos utilizados. Os resultados deste estudo in vitro mostraram que a irradiação com o laser de Er:YAG promoveram um padrão morfológico microrretentivo característico de ablação para todos os grupos testados e os grupos G1 e G4, que utilizaram a menor largura temporal de pulso (50 ?s), apresentaram uma superfície mais rugosa quando comparados aos demais grupos. Por fim, podemos concluir que a largura temporal de pulso influência nas características morfológicas da dentina irradiada nas diferentes indicações clínicas testadas, preparo cavitário e pré-tratamento. A menor largura de pulso (50 µs) produz uma morfologia mais irregular quando comparada as maiores larguras de pulsos (300 e 600 µs). / This study evaluated the morphological characteristics of Er:YAG laser irradiated dentin using different temporal pulses width on the protocols of cavity preparation and dentin pretreatment. Eighteen human molars were cut longitudinally in a mesiodistal direction and amelocemental junction providing dentin disks. Samples were polished in a decreasing silicon carbide paper to obtain standard 2mm thick disks. The experimental groups were divided by two variables: 1) clinical protocol - cavity preparation (E=200mJ/20Hz) and pretreatment (E=80mJ/2Hz); and 2) temporal pulse width - 50, 300 and 600µs. Therefore, six experimental groups were (n=3): G1(E=200mJ/20Hz/50µs); G2(E=200mJ/20Hz/300µs); G3(E=200mJ/20Hz/600µs); G4(E=80mJ/2Hz/50µs); G5(E=80mJ/2Hz/300µs); and G6(E=80mJ/2Hz/600µs). The samples were irradiated with the Er.YAG laser using wave-length of 2.94µm, in a non contact mode at a focal distance of 7mm from the target point under continuous water spray of 60-40ml/min. After the irradiation, the samples were processed and evaluated by scanning electron microscopic evaluation (SEM). The morphological analysis on the irradiated groups showed an irregular dentin surface, without smear layer, exposed dentinal tubules apertures, evidenced peritubular dentin, without carbonization and melting signs for all groups. A microretentive morphological pattern, characteristic of the ablation process could be observed in all groups. However, groups G1 and G4, that used 50?s of temporal pulse width, presented a greater irregularity when compared to other groups. In conclusion, the temporal pulse width interfere on the morphological characteristic of the irradiated dentin, regardless of clinical protocol, cavity preparation and pretreatment. The shorter the pulse width (50µs), the greater the surface irregularity.
373

Caracterização molecular e morfológica de isolados brasileiros do gênero Euglena. / Molecular and morphological characterization of Brazilian isolates of the genus Euglena.

Martins, Adriana Vieira de Castro 12 February 2009 (has links)
Neste estudo foram isolados e caracterizados flagelados de 20 amostras de solo e água do Brasil classificados no gênero Euglena por parâmetros taxonômicos tradicionais, e distribuídos em 5 grupos de acordo com características morfológicas. Análises filogenéticas do gene SSUrDNA das 20 amostras resultou em 25 seqüências posicionadas nos grupos A2 e A3 do gênero Euglena definidos em estudos anteriores, separando as seqüências obtidas em 7 clados distintos, revelando uma maior diversidade que a obtida por parâmetros taxonômicos tradicionais. A fim de resolver os relacionamentos intra-específicos do grupo A3, realizamos uma análise filogenética restrita deste grupo, que apresentou árvores congruentes e subclados bem suportados. Representantes de cada espécie foram analisados por microscopia eletrônica de varredura, revelando dois padrões principais de estrias e poros da película. Os isolados caracterizados neste estudo são os primeiros do Brasil estabelecidos em cultura, validados por análises filogenéticas e morfologicamente caracterizados. / In this study we isolated and characterized flagellates from 20 soil and water samples of Brazil, classified in the genus Euglena based on traditional taxonomic parameters and distributed in 5 groups according to morphological characteristics. Phylogenetic analyses of the SSUrDNA of the 20 samples resulted in 25 sequences that where positioned in previously defined groups A2 and A3 of the genus Euglena, separating the obtained sequences in 7 distinct clades, revealing a larger diversity than defined by traditional taxonomic parameters. To better resolve the intra-specific relationships of group A3, we conducted a phylogenetic analyses restricted to this group, generating congruent trees and well supported sub-clades. A representative of each species was selected and analyzed by scanning electron microscopy, revealing two major patterns of strip and pellicle pores. The isolates characterized in this study are the first in Brazil to be established in culture, validated by phylogenetic analyses and morphologically characterized.
374

Um novo algoritmo de granulometria com aplicação em caracterização de nanoestruturas de silício. / A new correlation-based granulometry algorithm with application in characterizing porous silicon nanomaterials.

Maruta, Ricardo Hitoshi 14 October 2011 (has links)
Granulometria é o processo usado para medir objetos de diferentes tamanhos em imagens de material granular. Frequentemente algoritmos baseados em morfologia matemática ou detecção de arestas são utilizados para esta finalidade. Propomos uma nova abordagem para a granulometria utilizando correlações cruzadas com círculos de tamanhos diferentes. Esta técnica é primeiramente adequada para a detecção de objetos de formato circular, mas pode ser estendido para outras formas utilizando outros núcleos (kernels) de correlação. Experimentos mostram que o novo algoritmo é robusto ao ruído e pode detectar objetos com pouco contraste e/ou com sobreposição parcial. Este trabalho também apresenta características quantitativas estruturais da camada de silício poroso, obtidas aplicando o algoritmo proposto em imagens de microscopia eletrônica de varredura (MEV). O novo algoritmo, que chamamos Granul, calcula as áreas e frequências dos poros. Processamentos adicionais utilizando outros algoritmos classificam os poros em circulares ou quadrados. Relacionamos os resultados quantitativos obtidos com o processo de fabricação e discutimos o mecanismo de formação do poro quadrado no silício. O novo algoritmo mostrou-se confiável no processamento de imagens de MEV e é uma ferramenta promissora para controle no processo de formação dos poros. / Granulometry is the process of measuring the size distribution of objects in an image of granular material. Usually, algorithms based on mathematical morphology or edge detection are used for this task. We propose a entirely new approach for the granulometry using the cross correlations with circles of different sizes. This technique is primarily adequate for detecting circular shaped objects, but it can be extended to other shapes using other correlation kernels. Experiments show that the new algorithm is greatly robust to noise and can detect even faint objects and/or objects with partial superposition. This paper also reports the quantitative structural characteristics of the porous silicon layer based on the proposed algorithm applied to Scanning Electron Microscopy (SEM) images. The new algorithm, that we call Granul, computes the size distribution of pores and classifies the pores in circular or square ones. We relate these quantitative results to the fabrication process and discuss the square porous silicon formation mechanism. The new algorithm shows to be reliable in SEM images processing and is a promising tool to control the pores formation process.
375

Perfilometria e microscopia eletrônica de varredura da superfície dentinária após escovação com cremes dentais dessensibilizantes e desafio erosivo com fruta amazônica / Profilometry and scanning electron microscopy of dentin surface after brushing with desensitizing toothpastes and challenge

Rocha, Max Pinto da Costa da 13 December 2012 (has links)
O objetivo deste estudo in vitro foi avaliar o potencial erosivo de suco de fruta amazônica ácida sobre a superfície dentinaria associado ao efeito abrasivo de diversos cremes dentais contendo agentes dessensibilizantes. O trabalho foi dividido em 3 fases distintas: Na fase 1, o valor do pH inicial de diversas frutas amazônicas foi medido utilizando 50 ml de cada suco, obtido de polpa industrializada. Foi utilizado um eletrodo de pH calibrado e a água destilada foi utilizada como controle. Na fase 2, 120 espécimes de dentina bovina foram submetidos a ciclos alternados de desafio abrasivo e erosivo, com a fruta escolhida na fase 1. Os espécimes foram divididos aleatoriamente em Grupo A (Desafio Abrasivo) e Grupo B (Desafio Erosivo e Abrasivo). Cada um destes grupos foram subdivididos em 5 subgrupos: 1: Água Destilada (Controle Negativo), 2: Colgate Tripla Ação (Controle Positivo), e os demais de acordo com o creme dental utilizado 3: Sensodyne Rápido Alívio, 4: Colgate Pró-Alivio e 5: Sensodyne Repair&Protect, (n=9). Na fase 3 foi realizado microscopia eletrônica de varredura para avaliar qualitativamente os espécimes (n=3). - O suco da fruta taperebá (Spondias mombin) apresentou os menores valores de pH, diante disso, foi escolhido como agente erosivo; Os testes de Kruskall Wallis e Teste de Dunn, mostraram que para os grupos nos quais somente a abrasão foi realizada, todos os cremes dentais mostraram comportamentos semelhantes em relação a perfilometria, não havendo diferença estatisticamente significante entre os grupos. Porém, para os grupos nos quais o processo erosivo foi adicionado, observou-se a potencialização do processo abrasivo, sendo que os cremes dentais Sensodyne Rápido Alivio e Colgate Sensitive Pro-Alivio foram os que mostraram menores alterações superficiais no padrão de perfilometria, comparados com o grupo controle negativo. Já os cremes dentais, Colgate Tripla Ação (controle positivo) e Sensodyne Repair&Protect apresentaram-se semelhantes entre si e com uma perda de estrutura dentinaria. mais significante. Conclui-se que o efeito erosivo da fruta amazônica taperebá é fator de grande importância na potencialização do efeito abrasivo, mesmo quando do uso de cremes dentais com agentes dessensibilizantes.. Na análise qualitativa da superfície dentinária em MEV, com exceção do Colgate tripla ação, os demais grupos não apresentaram oclusão tubular após o desafio ácido / The aim of this in vitro study was to evaluate the erosive potential of amazonian fruit juice with or without the abrasive challenge with various toothpastes containing desensitizing agents. The work was divided into three phases: in phase 1, the pH of various Amazonian fruits was evaluated. In step 2 it was performed surface perfilometry of the specimens, and in phase 3 it was evaluated qualitatively the dentin surface. In step 1, the initial pH value of several amazonian fruits was measured using 50 mL of each juice, from industrialized pulp. It was used a calibrated pH electrode, and distilled water was used as control. In step 2, 120 bovine dentin specimens were subjected to alternate cycles of abrasive and erosive challenge, with the fruit chosen in step 1. The specimens were randomly divided into Group A (without erosion) and Group B (with erosion). Each of these groups were divided into 5 groups: 1: Distilled Water, 2: Colgate Tripla Ação, 3: Sensodyne Rápido Alívio, 4: Pro-Alivio, 5: Sensodyne Repair & Protect, (n = 9). In Phase 3 it was conducted scanning electron microscopy to evaluate qualitatively the specimens (n=3). As a result it can be stated that: 1. The juice of the taperebá fruit had the lowest pH values, so it was chosen as the erosive agent; 2. For the groups in which only the abrasion was performed, all toothpastes showed similar behaviors, no statistically significant difference was observed between groups, but for the groups in which the erosion process was added, there was a potentiation of the abrasive process, and the toothpastes showed different profiles. The toothpaste Sensodyne Rapido Alívio Pró-Alívio was the ones that showed lower mineral loss, compared with the negative control group. Colgate Tripla Ação and Sensodyne Repair&Protect were similar among themselves and with a more significant mineral loss. It can be conclude that erosive effect of diet is a factor of great importance in the potentiation of abrasive effect. Clinical studies are essential to determine the dentin hypersensitivity levels after use of toothpaste used.
376

Estudo longitudinal da resistência e qualidade de união de diferentes sistemas adesivos à dentina irradiada com laser de femtossegundos / Long term evaluation of bond strength and quality of the interface of different adhesive systems to femtosecond laser irradiated dentin

Moretto, Simone Gonçalves 17 December 2012 (has links)
Recentemente, os lasers de pulsos ultracurtos têm sido avaliados para o preparo dos tecidos duros dentais devido à sua habilidade de reduzir os efeitos térmicos resultantes da irradiação. O objetivo deste estudo foi avaliar a efetividade de união de 3 sistemas adesivos à dentina preparada com o laser de femtossegundos (10-15 s). Para isso, 60 terceiros molares foram preparados com o laser de femtossegundos (1.450 nm; 0,3W; 100.000Hz) ou ponta diamantada, divididos em 3 subgrupos (n=10) restaurados utilizando o adesivo condicione e lave de 3 passos Optibond FL (OFL; Kerr), o autocondicionante de 2 passos Clearfil SE (CSE; Kuraray) ou o autocondicionante de 1 passo G-aenial Bond (GAB; GC). Após 1 semana de armazenamento em água, os dentes foram seccionados (1,0x1,0 mm) e testados imediatamente e após 6 meses de armazenamento. Vinte e quatro amostras adicionais foram preparadas com o laser ou ponta diamantanda conforme descrito acima. Seis amostras foram seccionadas em espécimes menores e aleatoriamente preparados para observação das características morfológicas da superfície (n=3) e subsuperfície (n=3) em Microscópio Eletrônico de Varredura (MEV) (n=3) e Microscopia Eletrônica de Transmissão (MET) (n=3). As outras 18 amostras foram restauradas com os sistemas adesivos supramencionados, seccionados em espécimes menores e distribuídos para avaliação da interface adesiva em MEV (n=3) e padrão de nanoinfiltração após 1 semana (n=2) e 6 meses (n=2) em MET. O modelo linear de efeitos mistos (=0,05) revelou um efeito significante dos fatores adesivo, armazenagem e a interação preparo x armazenagem na resistência de união. Todos os adesivos apresentaram uma redução significante da resistência de união após 6 meses de armazenamento (p<0,0001) para ambos os tipos de preparo. Com relação ao sistema adesivo, a única diferença verificada foi o maior valor de resistência de união do GAB quando aplicado sobre as superfícies irradiadas (56,71±10,72 MPa) quando comparadas com as preparadas com ponta diamantada (43,14±14,93 MPa) após 1 semana de armazenamento. A análise de fratura revelou fraturas mistas, adesivas e coesivas em dentina para ambos os métodos de preparo com um discreto aumento do número de fraturas mistas após 6 meses de armazenamento exceto para o GAB, que apresentou principalmente fraturas adesivas e mistas. A análise em MEV revelou uma fina camada de debris sobre a superfície da dentina irradiada e a hibridização com todos os sistemas adesivos resultou num íntimo contado da interface adesiva com o substrato. A análise em MET da subsuperfície irradiada revelou fibrilas colágenas preservadas. A análise da interface adesiva revelou um aumento dos depósitos de prata na camada híbrida para todos os adesivos, após 6 meses de armazenamento, independentemente do tipo de preparo. Apenas o GAB apresentou maiores depósitos de prata após 1 semana de armazenamento para as superfícies preparadas com ponta diamantada. A irradiação com o laser de femtossegundos não reduziu a receptividade da dentina aos sistemas adesivos, resultando em valores de resistência de união similares aos obtidos com a ponta diamantada; além de uma ótima interação do substrato com os sistemas adesivos e deposições de prata similares àquelas obtidas com a ponta diamantada. / Recently, the applicability of ultrashort pulsed lasers has been studied for dental hard-tissue irradiation because of its reduced residual thermal damage. The aim of this study was to determine the bonding effectiveness of 3 contemporary adhesive systems to dentin prepared by femtosecond (10-15 sec) laser-irradiation. For this, 60 third molars were prepared either by the femtosecond laser (1450 nm; 0.3W; 100,000Hz) or by bur, randomly divided into 3 subgroups (n=10) and restored with a composite using either the 3-step etch-and-rinse adhesive Optibond FL (OFL; Kerr), the 2-step self-etch adhesive Clearfil SE (CSE; Kuraray) or the 1-step self-etch adhesive G-aenial Bond (GAB; GC). After 1-week water storage, the teeth were sectioned (1.0x1.0 mm) and half of the specimens were tested until failure using a micro-tensile bond-strength (TBS) approach. The other half was stored in water and tested after 6 months. Twenty-four additional dentin samples were exposed to the diamond bur and the laser, following the same abovementioned parameters. Three samples of each treatment were sectioned in smaller specimens in order to be characterized for surface (n=3) and cross-sectional morphological analysis using Scanning Electron Microscopy (SEM) (n=3) and Transmission Electron Microscopy (TEM) (n=3). The other eighteen samples were hybridized with the abovementioned adhesive systems, sectioned in smaller samples and distributed for evaluation of the interface under SEM (n=3) and nanoleakage distribution for 1 week (n=2) and 6 months (n=2) under TEM. Linear mixed effect model (=0.05) revealed a significant effect of the factors adhesive, storage and the interaction of preparation x storage on the TBS. All adhesives presented a significant reduction of the bond strength after 6-month storage (p<0.0001) for both preparation methods. Regarding the adhesive system, the only difference found was a significantly higher TBS of GAB to laser-irradiated (56.71±10.72 MPa) than to bur-cut dentin (43.14±14.93 MPa) after 1-week water storage. Fracture analysis showed mixed, adhesive and cohesive failures in dentin similarly for both preparation methods with a slightly increase of the mixed failures after 6-months water storage for OFL and CSE, but not for GAB that presented mainly adhesive and mixed failures. SEM disclosed a thin layer of debris on the laser-irradiated dentin surface and the hybridization with all adhesive systems resulted in a very tight interface. TEM analysis of the irradiated subsurface revealed collagen fibrils preserved and for the nanoleakage evaluation an increase of silver deposits at hybrid layer for all adhesives testes after 6-months water storage, irrespective of the preparation methods. Only the GAB presented great silver deposits even after 1-week water storage for the bur-cut preparation method. Femtosecond laser irradiation did not reduce the bonding receptiveness of dentin resulting in similar values obtained with the preparation by bur. Additionally it led to a great interaction with different adhesive systems and silver deposits comparable to those obtained with the bur-cut preparation method.
377

"Influência de parâmetros metodológicos sobre o ensaio de microtração. Microscopia eletrônica de varredura e resistência de união" / Influence of methodological parameters on microtensile test. Scanning electron microscopy and bond strength measurements

Sadek, Fernanda Tranchesi 21 October 2005 (has links)
Foi verificada a influência de 6 variáveis experimentais sobre o ensaio de microtração, a saber: sistema adesivo, formato e área de união dos corpos-de-prova (cps), velocidade e equipamento de corte e definição do grupo amostral no tratamento estatístico. Todas as variáveis foram testadas em esmalte e dentina previamente planificados. Para isolar as variáveis, o estudo foi dividido em quatro fases. 1) testou-se o tipo de adesivo: 28 molares humanos foram divididos em 4 grupos, de acordo com o substrato e com o adesivo utilizado (Excite e Clearfil SE Bond). 2) 64 dentes divididos em 16 grupos foram usados para testar: formato (ampulheta ou palito) e área de união dos cps. 3) testou-se a velocidade de corte para a obtenção dos cps, usando-se 30 molares divididos em 6 grupos. 4) 40 molares divididos em 8 grupos foram usados para analisar: equipamento de corte (disco ou fio impregnados por diamante), formato dos cps e delimitação do grupo amostral. Em todas as fases, cps foram selecionados e preparados para MEV, enquanto o restante foi submetido ao teste de microtração. Os valores de resistência de união [RU] foram coerentes com os achados em MEV, sendo os maiores valores encontrados nos grupos com melhor integridade superficial. Foi possível observar que não houve diferença estatística entre o substrato e o adesivo utilizado na fase 1. Apesar de ambos os adesivos terem conseguido íntimo contato com o substrato adjacente, muitos defeitos estruturais foram observados em MEV, principalmente em esmalte. Na fase 2, cps em dentina e em forma de palito apresentaram valores significantemente maiores de RU do que cps em esmalte e em forma de ampulheta, respectivamente. Em relação à área dos cps, quando essa aumentou de 0,25 para 4,0 mm 2 , a RU diminuiu significantemente. Foi possível verificar em cps com forma de ampulheta, através da MEV, linhas de fraturas juntamente à área de ação da.ponta diamantada, além de defeitos nos cps em forma de palito, sendo que o esmalte foi mais afetado do que a dentina. Já na fase 3, cps em dentina apresentaram maior RU do que cps em esmalte. A velocidade de corte não influenciou nos resultados dos cps em dentina, influenciando, contudo, a RU daqueles em esmalte, sendo que os cortados com velocidade alta (400 RPM) mostraram defeitos mais pronunciados em MEV e menores RU do que os cortados com velocidades menores (100 e 200 RPM). Na fase 4, cps em esmalte cortados com o fio impregnado por diamante foram estatisticamente mais resistentes do que aqueles cortados com disco, sendo que este grupo apresentou maior quantidade de defeitos em MEV, o mesmo não acontecendo em dentina. Cps em forma de palito foram mais resistentes do que aqueles em forma de ampulheta. A inclusão/exclusão das fraturas prematuras foi estatisticamente significante para ambos os substratos. Concluímos que cps em forma de ampulheta devem ser evitados, principalmente em esmalte, recomendando, assim, o uso de cps em forma de palito, com áreas próximas a 1 mm 2 . O seccionamento para obtenção dos cps em esmalte deve ser feito preferencialmente com fio. Quando a utilização do disco for inevitável, velocidades baixas são aconselháveis. A inclusão das fraturas prematuras, como valor de resistência de união igual a zero, proporciona resultados mais representativos sobre o complexo processo que envolve o teste de microtração. / The influence of 6 methodological parameters in the results of the microtensile test was evaluated, as described: adhesive system, shape and area of the specimens, cutting speed and equipment, experimental groups’ definition for the statistical analyses. All variables were tested in flattened dentin and enamel. 1) The type of adhesive system was evaluated: 28 human molars were divided into 4 groups according to the substrate and the adhesive used (Excite or Clearfil SE Bond). 2) 64 teeth divided into 16 groups were used to test: shape (hourglass and stick) and area of the specimens. 3) Cutting speed used to obtain specimens was tested, using 30 molars divided into 6 groups. 4) 40 molars were divided into 8 groups and used to analyze: cutting equipment (blade or wire impregnated by diamond), shape of the specimens and experimental groups’ delimitation. In all the above trials, some specimens were randomly selected and prepared for SEM, while the remaining were submitted to microtensile test. Microtensile bond strength data collected was coherent to the SEM images observed; higher values were found for the groups wherein better integrity was observed. It was possible to verify that there were no statistically differences between substrates and adhesives used in the first trial. Even tough both systems showed intimate contact with the adjacent tissue, many structural defects were observed in SEM, mainly in enamel. In the test 2, dentin and stick-shaped specimens gave significantly higher values of bond strength than enamel and hourglass-shaped specimens, respectively. As for specimens’ thickness, when it increases from 0.25 to 4.0 mm 2 , the recorded microtensile bond strength decreases. It was possible to verify, through SEM, line of fracture in the area of action of the bur in the hourglass-shaped specimens and structural defects in the stick-shaped specimens, being enamel more affected than dentin. In the third trial, specimens in dentin showed significantly higher values of bond strength than specimens in enamel..Cutting speed did not influence the results of the dentin’s specimens; however, it influenced those in enamel, where the ones cut with higher cutting speed (400 RPM) had more pronounced defects in SEM and lower bond strength values when compared to those cut with lower cutting speeds (100 and 200 RPM). In the experiment 4, enamel’s specimens sectioned with the diamond wire showed statistically higher bond strengths than those cut with blade, being this last group the one that showed more structural defects during SEM analyzes, which did not happen in dentin. Stick-shaped specimens were more resistant than hourglass-shaped specimens. The inclusion/exclusion of premature failures was statistically significant for both substrates. We conclude that hourglass-shaped specimens should be avoided, especially on enamel, where the use of stick specimens is highly recommended, with cross-sectional area of 1 mm 2 . The sectioning action to obtain enamel specimens should be done with wire equipments. However, when the use of diamond blade is unavoidable, low cutting speeds are advisable. Premature failures should be included as null bond strength values to represent fully all factors involved in the microtensile process.
378

Análise estrutural e ultra-estrutural dos músculos esternomastóideo e cleidomastóideo de ratos wistar adultos e idosos. / Structural and ultrastructural analysis of the sternomastoid and cleidomastoid muscles of the adults and aged Wistar rats.

Ciena, Adriano Polican 21 March 2011 (has links)
O objetivo do presente estudo foi analisar estrutural e ultra-estruturalmente os músculos EM e CM adultos e idosos empregando métodos de microscopia de luz, microscopia eletrônica de varredura, microscopia eletrônica de transmissão. Os resultados revelaram os feixes de fibras colágenas que constituem o endomísio, perimísio e epimísio presentes no tecido muscular. Nos capilares dos músculos adultos observou-se a presença de pseudópodos endoteliais projetando-se para o lúmen capilar; a referida estrutura não foi encontrada nos capilares dos músculos idosos examinados. A reação histoquímica de NADH-tr permitiu a identificação dos tipos de fibras: Oxidativa (O), Glicolítica-oxidativa (GO) e Glicolítica (G) nas regiões superficial e profunda dos músculos EM e CM de animais adultos e idosos. Todavia, constatou-se aumento da área de secção transversa das fibras O, GO e G. Paralelamente, os dados mostraram diminuição da densidade total das fibras, revelando a plasticidade e atrofia muscular nos músculos de animais com envelhecimento. / The aim of the present study was to analyse structural and ultrastructure of SM and CM of adults and aged animals employing light microscopy, scanning electron microscopy, transmission electron microscopy methods. The results revealed the bundles of collagen fibers which constituted the endomysium, perimysium and epimysium in the muscle tissue. In the capillaries of the adults muscles observed the presence of endotheliais pseudopod projected to the capillary lumen; this structure do not found in the capillaries of the examined aged muscles. The histochemical reaction of NADH-tr, allowed to identify three types of fibers: Oxidative (O), Oxidative-Glycolytic (OG) and Glycolytic (G) in the surface and deep regions of the SM and CM muscles of adult and aged animals. However, may observed an increased areas of the cross-section the fibers O, OG and G. Parallely, the data showed decreased total density of the fibers, revealing the muscle atrophy and plasticity of aging animals.
379

Efeito das pastilhas higienizadoras efervescentes à base de peróxido alcalino em liga metálica de cobalto-cromo / Effect of alkaline peroxide-effervescent tablets on the surfaces of the cobalt-chromium alloys

Glenda Lara Lopes Vasconcelos 17 December 2015 (has links)
A higienização das próteses é de fundamental importância para a longevidade do tratamento reabilitador. Entretanto, é necessário analisar os efeitos que os higienizadores podem causar nas superfícies que compõem uma prótese. Deste modo, o objetivo deste estudo foi avaliar os efeitos de pastilhas efervescentes à base de peróxido alcalino em liga de cobalto cromo (Co-Cr), utilizada em Prótese Parcial Removível (PPR). A partir de uma matriz metálica, padrões de cera em forma de disco (12 mm x 3 mm) foram confeccionados para posterior fundição. Os espécimes metálicos (n=16) foram imersos nas soluções: água deionizada (controle), Polident 3 minutes®, Steradent®, Efferdent®, Polident for Partials® e Corega Tabs®. Foi realizada a análise da rugosidade (n=10) por meio de rugosímetro, antes (t0) e após 5 períodos de simulação de ½, 1, 2, 3, 4 e 5 anos de imersão nos higienizadores. Foram realizadas análises complementares quantitativas da liberação de íons (n=5) de cobalto (Co), cromo (Cr) e molibdênio (Mo) em cada solução e análises qualitativas em um espécime de cada grupo, por meio de Microscopia Eletrônica de Varredura (MEV) e Espectrometria de Energia Dispersiva de Raios X (EDS). A distribuição dos dados de rugosidade (&mu;m) apresentou-se não normal. Foi utilizada estatística não-paramétrica (&alpha;=0,05). Tanto para o fator solução (Kruskall Wallis, ½ ano (p=0,900), 1 ano (p=0,277), 2 anos (p=0,227), 3 anos (p=0,086), 4 anos (p=0,657) e 5 anos (p=0,856), como para o fator tempo (Friedman, p=0,137) não houve diferença significante. Com relação à liberação de íons (&mu;g/L), a distribuição dos dados apresentou-se normal. De acordo com a estatística (&alpha;=0,05, ANOVA e teste de Tukey), Corega Tabs®, Efferdent® e água deionizada promoveram maior liberação de íons Co do que o Steradent® (p=0,003). Quanto aos íons Cr (p=0,000), Corega Tabs® propiciou maior liberação quando comparado a água deionizada, Steradent® e Polident 3 minutes®. Em relação aos íons Mo (p=0,001), o Efferdent® promoveu maior liberação. No MEV pode-se verificar que as soluções não apresentaram efeitos deletérios sobre as superfícies. Conclui-se que todas as pastilhas avaliadas não ocasionaram danos, entretanto, Steradent® foi a que propiciou menor liberação de íons, sendo indicada com maior segurança para higienização de superfícies metálicas de PPR. / The hygiene care of the removable dentures is of most importance for the longevity of the rehabilitation treatment. However, it is necessary to analyze the effects that denture cleansers can cause on the surfaces of prosthesis. Thus, the aim of this study was to evaluate the effect of alkaline peroxide-effervescent tablets on the surfaces of the cobalt-chromium alloys (Co-Cr), used in removable partial dentures (RPD). Circular specimens (12 mm x 3 mm) were fabricated with cobalt-chromium alloys. The specimens (n= 16) were immersed in the following solutions: deionized water (control), Polident 3 minutes&trade;, Steradent&trade;, Efferdent&trade;, Polident for Partials&trade; and Corega Tabs&trade;. The surface roughness (n=10) was analyzed with a surf-test analyzer, before and after 5 periods that corresponds to the simulation of ½, 1, 2, 3, 4 and 5 years of immersion in the cleansers. As complementary analysis, it was performed a quantitative study of ions release (n=5) for cobalt (Co), chromium (Cr) and molybdenum (Mo) in each solution and qualitative analysis with scanning electron microscopy (SEM) associated to Energy-dispersive X-ray spectroscopy (EDS). The results of surface roughness had presented no normal. In nonparametric statistics (&alpha; = 0.05), both of the solution factor Kruskall Wallis, ½ year (p=0.900), 1 year (p=0.277), 2 years (p=0.227), 3 years (p=0.086), 4 years (p=0.657) and 5 years (p=0.856), such as time factor (Friedman, p = 0.137), there was no significant difference. The results of ionic release presented a normal distribution and they were submitted to ANOVA (p=0.05) and Tukey test. The solutions Corega Tabs®, Efferdent® and deionized water presented greater Co ionic release than Steradent® (p=0.003). For Cr ions (p=0.000), Corega Tabs® had greater ionic release than deionized water, Steradent® and Polident 3 minutes®. Regarding Mo ions (p=0.001), Efferdent® showed greater release. With SEM, it was possible to verify that the solutions showed no deleterious effects on the specimen surfaces. It was concluded that no deleterious effects on metal surface was caused, however, Steradent® presented the smallest ionic release, and can be indicated more safely for cleaning metal surfaces of RPD.
380

Quantificação do potencial osteogênico in vivo do osso autógeno + células osteoblásticas carreadas por uma biocerâmica composta de hidroxiapatita e fosfato tricálcio-&beta;: Estudo qualitativo e quantitativo em microscopia de luz e eletrônica de varredura / Quantification of the osteogenic potential in vivo of autogenous bone + osteoblastic cells carried by a bioceramic consisting of hydroxyapatite and &beta;-tricalcium phosphate: A qualitative and quantitative study by light and scanning electron microscopy

Rander Moreira Macedo 21 June 2013 (has links)
Durante e após o processo de reparo alveolar pós-extração, ocorre certa remodelação óssea com reduções dimensionais deste tecido podendo comprometer a terapia em implantodontia. A fim de preservar/reconstruir tal tecido, vários métodos são propostos usando diferentes tipos de biomateriais e técnicas, os quais demonstram capacidade em formar osso. O osso autógeno ainda é considerado a referência padrão como enxerto ósseo, devido ao seu potencial osteogênico, osteoindutor e osteocondutor, mas morbidade relativa a este é conhecida. Por isso algumas biocerâmicas têm sido utilizadas, pois são sintéticas, biocompatíveis e com boas propriedades osteopreenchedoras, mas com baixa osteogenicidade. A engenharia tecidual óssea constituída de células tronco mesenquimais diferenciadas em osteoblastos é uma estratégia para o fornecimento adicional celular ao defeito ósseo em reconstrução. O objetivo deste estudo foi qualificar e quantificar a reparação óssea após o enxerto de uma associação de osso autógeno e células osteoblásticas carreadas por uma biocerâmica em defeitos ósseos produzidos pela extração dentária. Os animais foram divididos de acordo com o material implantado no alvéolo dentário pós-extração em: Controle (c), osso autógeno (oa), células osteoblásticas (co), biocerâmica (bc), osso autógeno + células osteoblásticas (oa+co), osso autógeno + biocerâmica (oa+bc), biocerâmica + células osteoblásticas (bc+co), e biocerâmica + células osteoblásticas + osso autógeno (bc+co+oa). O sacrifício ocorreu aos 7, 21 e 42 dias pós-cirurgia e as amostras teciduais foram processadas para análise em microscopia de luz e eletrônica de varredura. Através de um sistema de análise de imagens foi avaliado a qualidade dos biomateriais implantados e o volume de osso, biocerâmica, conjuntivo e coágulo no defeito ósseo. Os resultados qualitativos revelaram que a biocerâmica implantada foi biocompatível e estava intimamente unida ao osso. O uso das células osteoblásticas, do osso autógeno ou da biocerâmica não desencadearam reações imunogênicas, de corpo estranho ou formação tumoral. Histometricamente as células osteoblásticas carreadas pela biocerâmica mostraram um preenchimento ósseo 19,0% maior do que quando não carreadas. A associação biocerâmica/células osteoblásticas + osso autógeno promoveu, aos 7 dias, uma deposição óssea 56,52% mais efetiva nos arredores do biomaterial do que a enxertia da biocerâmica isoladamente (1%). Conclui-se que a biocerâmica em questão pode ser um viável carreador às células osteoblásticas a serem enxertadas em sítios de reconstrução óssea, e que este composto híbrido recebe um efeito sinérgico quando da associação ao osso autógeno, sendo capaz desta forma de acelerar o processo de neoformação óssea principalmente nos períodos iniciais da reparação alveolar. / During and after the process of alveolar repair post-extraction, bone remodeling occurs with certain dimensional reductions of this tissue that can compromise the therapy in implantology. In order to preserve/reconstruct such tissue, various methods are proposed using different types of biomaterials and techniques which demonstrate the capacity to form bone. The autogenous bone is still regarded as the gold standard bone graft, due to their osteogenic, osteoinductive and osteoconductive potential, but morbidity is known about it. Therefore some bioceramics have been used, as they are synthetic, biocompatible and with good properties of bone fill, but with low osteogenic potential. The bone tissue engineering consists of mesenchymal stem cells differentiated into osteoblasts is a strategy for providing additional cell in the bone defect reconstruction. The aim of this study was to qualify and quantify bone healing after grafting of an association of autogenous bone and osteoblastic cells carried by a bioceramic in bone defects produced by tooth extraction. The animals were divided according to the implanted material in dental socket after extraction: Control (c), autogenous bone (ab), osteoblastic cells (oc), bioceramic (bc), autogenous bone + osteoblastic cells (ab+oc), autogenous bone + bioceramic (ab+bc), bioceramic + osteoblastic cells (bc+oc), and bioceramic + autogenous bone + osteoblastic cells (bc+oc+ab). The animals were sacrificed at 7, 21 and 42 days post-surgery and tissue samples were processed for light microscopy and scanning electron microscopy. Through an image analysis system the quality of implanted biomaterials and the volume of bone, bioceramic, conjunctive tissue and blood clot was evaluated inside the bone defect. Qualitative results revealed that the grafted bioceramic was biocompatible and intimately bonded with the bone. The use of osteoblastic cells, autogenous bone or bioceramic didnt trigger immunogenic reactions, foreign body or tumor formation. Histometrically, the osteoblast cells carried by bioceramic showed a bone filling 19.0% higher than when not carried. The bioceramic/osteoblastic cells + autogenous bone association promoted, at 7 days, a bone deposition 56.52% more effective around the biomaterial than the grafting of bioceramic alone (1%). It was concluded that the bioceramic in question may be a viable carrier to osteoblastic cells to be grafted on sites of bone reconstruction, and this hybrid compound receives a synergistic effect when associated to autogenous bone, thus being able to accelerate the bone formation especially in the early periods of alveolar repair.

Page generated in 0.6543 seconds