1

Energiutredning av kvarteret Masten

Bergström, Anna January 2010 (has links)
<p>I detta arbeta har en energiutredning av fastigheten Kvarteret Masten gjorts. Kvarteret Masten ligger på Nygatan 43 och Centralgatan 9 i Gävle. Fastigheten består av 30 hyreslägenheter och 3 butiker. En energiutredning innebär att energianvändningen delas upp i två delar, en tillförd och en bortförd.  I den tillförda energin ingår den köpta energin i form av fjärrvärme samt gratisenergin som kommer från personer, solen, belysning och elektrisk utrustning.  Bortförda energin består av transmissioner, ventilation, tappvarmvatten samt en ofrivilig ventilation. Transmissioner är förluster genom byggnadens konstruktionsdelar som väggar, tak, golv, fönster och dörrar. För att få reda på transmissionsförlusterna måste U-värdet (värmegenomgångsmotståndet) för varje konstruktionsdel beräknas. Som hjälpmedel till transmissionsberäkningar har befintliga ritningar av byggnaden används. Underlag till ventilationsförlusterna är egna mätningar av lufthastigheten i ventilationskanalerna. För att energibalansen ska gå ihop måste den ofriviliga ventilationen tas med och den blev 5,7 % av den tillförda energin. Byggnadens energianvändning är 407241 kWh/år. Denna användning kan minskas med besparingsåtgärder. De åtgärderna som föreslås i utredningen är att installera ett återvinningsbatteri till butikernas till- och frånluft. Dessutom installera en extra värmeväxlare till fjärrvärmesystemet, för att förse det befintliga återvinningsbatteriet till lägenheterna med fjärrvärme. Med dessa åtgärder kan föreningen spara 18705 kr/år.  Förutom värmeförbrukningen har även fastighetens kylanläggning tittas på. Åtgärdsförslagen var att installera interna kylsystem i butikerna och undersöka om det skulle vara lönsamt, det andra alternativet var ta kyla från Gavleån. I detta arbete har bara kostnadskalkyl på interna kylsystem beräknats.</p>
2

Energiutredning av kvarteret Masten

Bergström, Anna January 2010 (has links)
I detta arbeta har en energiutredning av fastigheten Kvarteret Masten gjorts. Kvarteret Masten ligger på Nygatan 43 och Centralgatan 9 i Gävle. Fastigheten består av 30 hyreslägenheter och 3 butiker. En energiutredning innebär att energianvändningen delas upp i två delar, en tillförd och en bortförd.  I den tillförda energin ingår den köpta energin i form av fjärrvärme samt gratisenergin som kommer från personer, solen, belysning och elektrisk utrustning.  Bortförda energin består av transmissioner, ventilation, tappvarmvatten samt en ofrivilig ventilation. Transmissioner är förluster genom byggnadens konstruktionsdelar som väggar, tak, golv, fönster och dörrar. För att få reda på transmissionsförlusterna måste U-värdet (värmegenomgångsmotståndet) för varje konstruktionsdel beräknas. Som hjälpmedel till transmissionsberäkningar har befintliga ritningar av byggnaden används. Underlag till ventilationsförlusterna är egna mätningar av lufthastigheten i ventilationskanalerna. För att energibalansen ska gå ihop måste den ofriviliga ventilationen tas med och den blev 5,7 % av den tillförda energin. Byggnadens energianvändning är 407241 kWh/år. Denna användning kan minskas med besparingsåtgärder. De åtgärderna som föreslås i utredningen är att installera ett återvinningsbatteri till butikernas till- och frånluft. Dessutom installera en extra värmeväxlare till fjärrvärmesystemet, för att förse det befintliga återvinningsbatteriet till lägenheterna med fjärrvärme. Med dessa åtgärder kan föreningen spara 18705 kr/år.  Förutom värmeförbrukningen har även fastighetens kylanläggning tittas på. Åtgärdsförslagen var att installera interna kylsystem i butikerna och undersöka om det skulle vara lönsamt, det andra alternativet var ta kyla från Gavleån. I detta arbete har bara kostnadskalkyl på interna kylsystem beräknats.
3

Energiutredning av Kv. Salladen nr 9

Ek, Caroline January 2009 (has links)
No description available.
4

Utredning av värmesystem på ICA Kvantum Umeå / Investigation of the space heating system at ICA Kvantum Umeå

Mannberg, Andreas January 2012 (has links)
Sveriges totala energianvändning uppgick år 1970 till 457 TWh medan den idag är uppe i 600 TWh. Det visar hur kraftigt vår användning har ökat den senaste tiden och att vi nu bör göra något åt detta genom att energieffektivisera hela kedjan från produktion till användning. En undersökning som fastighetsbolaget ICA Fastighet AB genomfört visar på en genomsnittlig energianvändning bland livsmedelsbutiker på 421 kWh/m2,år. ICA Kvantum Kronoparken i Umeå har en specifik energianvändning på 658 kWh/m2,år vilket gör att butikens användning är hög och över medelvärdet. Projektets syfte är att utföra en fallstudie på ICA Kvantum Kronoparken i Umeå genom att kartlägga den totala energianvändningen utifrån utvalda användningsområden. Vidare skall olika alternativ till värmekälla undersökas för att byta ut den värmepanna som förser fastigheten med värme idag. Fastigheten har idag en total energianvändning på 2 237 MWh/år och en total uppvärmd yta på 3 400 m2. Kartläggningen genomfördes genom att dela upp totala användningen i sju huvudområden med förhoppning att finna de områden med stor energieffektiviseringspotential. Uppdelning enligt följande: Belysning Ventilation Uppvärmning Livsmedelkyla Komfortkyla Varmvatten Verksamhetsel Efter genomförd kartläggning visade det sig att livsmedelskylan står för närmare 42 % av den totala energianvändningen, och det är även där som den största besparingspotentialen finns. Andra största användare var verksamhetsel som står för 21 % och innefattar all övrig utrustning och användning förutom ovanstående användningsområden. De områden där energieffektiviserande åtgärder ansågs möjliga var belysning, ventilation samt livsmedelskyla. Efter samtliga effektiviseringsåtgärder ges en potentiell minskning av totala energianvändningen med närmare 20 % från 2 237 MWh/år ner till 1 818 MWh/år. Den specifika användningen på 534 kWh/m2,år som detta medför ligger fortfarande högt i jämförelse med det uppsatta medelvärdet. Fjärrvärme och bergvärme är de värmekällor som är ett bra alternativ för att byta ut befintlig elpanna. Fjärrvärmen har en lägre investeringskostnad och högre årskostnad jämfört med bergvärme som har det motsatta. Båda har en återbetalningstid på 4-6 år vilket anses som lönsamt. Projektet fokuserades på fastighetens uppvärmning vilket endast motsvarar 7 % av totala energianvändningen. Detta kan jämföras med livsmedelskylan som motsvarar 42 %. Hade projektet fokuserats mer på livsmedelskylan istället kan en större besparing blivit möjlig. Att välja miljövänligare alternativ till elpannan är aldrig fel och de båda alternativen ger bra avkastning på investerade pengar. Som rekommendationer till fortsatt arbete bör frikyla undersökas närmare. Det används inte idag och kan vara en av många faktorer som utgör fastighetens höga energianvändning. / The total energy consumption in Sweden reached 457 TWh in the year of 1970, and today is 600 TWh. It shows how our use has increased recently and that we should do something about it. The whole chain from energy production to energy use needs to be more efficient. A study conducted by ICA Fastighet AB shows an average energy use among grocery stores of 421 kWh/m2 year. ICA Kvantum Kronoparken in Umeå has a specific energy use of 658 kWh/m2 year, it shows that the energy use is high and above the mean average. The project aims is to conduct a case study at ICA Kvantum Kronoparken in Umeå by mapping the total energy use by the selected energy use categories in the shop. Furthermore, investigate various alternatives to replace the electric boiler which supplies the building with heat today. Today, the property has a total energy use of 2 237 MWh/year in a heated area of 3 400 m2. The analysis was conducted by separating the total energy use in seven main categories. By doing that it is easy to find the categories of high energy efficiency potential. Separation as follow: Lights Ventilation Heating Food cooling Comfort cooling Hot water Operational electricity After completing the case study it showed that food cooling is responsible for approximately 42 % of total energy use, and also there you have the highest potential in saving energy and money. Other major users are area operational electricity which accounts for 21 % and includes all other equipment and use in addition to the above categories. The areas where energy efficiency measures were possible are lights, ventilation and cooling food. After these measures a given potential of the total energy use reduction by 20 % from 2 237 MWh/year down to 1 818 MWh/year. District heating and geothermal heating are the heat sources which best could replace the existing electric boiler. District heating has a lower investment cost and higher annual cost than geothermal heat, which is the opposite. Both have a payback period of 4-6 years which is considered as viable. The project focused on the property heating system, which only represents 7 % of total use. That compares to cooling food which represent 42 %. If the project was focused on food cooling rather than the heating system greater savings may has become possible. A recommendation for the future is to explore the cooling food system more, and also study and explore if free cooling is possible in winter. Today is not used, and it may be one of many factors that make the property’s energy use so high.
5

En energiutredning och miljöklassning av Hemsta 12:16

Hjelm, Dan, Wallby, Martin January 2012 (has links)
The purpose of this study was to implement an energy analysis and environmental evaluation of the property Hemsta 12:16 in Gävle. Based on two different methods, Energy Balance calculation and Environmental Building, the result of the property's energy use, energy performance and environmental impacts are presented. Except that, measures to reduce final energy consumption are presented.       The proposed measures can reduce energy usage by 100 400 kWh / year, which represents a decrease of 18% of the present energy usage. This would represent a total savings of 63 000 SEK per year. In addition, the environmental performance is improved by adopting the suggested measures.
6

Energiutredning av Kv. Salladen nr 9

Ek, Caroline January 2009 (has links)
No description available.
7

Energiutredning på Chips AB, Åland / Energy Analysis at Chips AB, Åland

Renström, Thom, Sundbäck, Henrik January 2013 (has links)
En energikartläggning har gjorts hos Chips AB för att undersöka hur energin fördelas över de olika produktionslinjerna. Energianvändningen från processer som är gemensamma för alla produktionslinjer har också undersökts. Energianvändningen för dessa har fördelats över pro- duktionslinjerna eftersom produkterna även ska bära upp dessa energikostnader. Där det vi- sade sig att chipslinjen använder överlägset mest energi under ett år, 13 200 MWh, men den linjen körs mest också. Näst störst energianvändning hade moslinjen som bara låg på 6 600 MWh. När energianvändningen beräknades per producerat kilogram visade det sig att det var moslinjen som använder mest energi, 2,75 kWh/kg. Från energianvändningen beräknades kostnad och koldioxidutsläpp, både totalt och per pro- ducerat kilogram. Här visade det sig att moslinjen även har högst koldioxidutsläpp och högst kostnad per producerat kilogram. Chipslinjen har näst högst koldioxidutsläpp per producerat kilogram, men det är de friterade produkterna från PF2-linjen som har näst högst kostnad per producerat kilogram. Det beror på att det är olja som används till fritösen i PF2-linjen. Flera åtgärdsförslag för att minska energianvändningen har tagits fram. Det var två skorstenar som hade mycket överskottsvärme som kan användas, chipsfritösen och PF1-fritösen. De bästa förslagen skulle vara att använda denna överskottsvärme till uppvärmning av lokaler och tappvarmvatten samt uppvärmning av blanchörvatten. Tillsammans skulle detta i bästa fall kunna ge en årsbesparing på ungefär 516 000 € och ändå ha en återbetalningstid under ett år. Andra åtgärdsförslag som också undersöktes var förvärmning av luften till chipspannan, absorptionskyla och elproduktion, men dessa förslag hade mindre besparingspotential och längre återbetalningstid än det första förslagen. / An energy analysis has been made at Chips AB to investigate how the energy is distributed over the various production lines. Energy from processes common to all production lines have also been investigated. Energy use for these have been distributed over the production lines since the products also should carry these energy costs. There, it is shown that the potato chips line is using by far the most energy in a year, 13,200 MWh, but it is the line that runs the most too. The potato mash line had the second largest energy use, at 6,600 MWh. But when the energy usage was calculated per kilogram produced, it turned out that it was the potato mash line that use the most energy, 2.75 kWh/kg. From the total energy use the cost and carbon emissions were calculated, both in total and per produced kilogram. Here it showed that the potato mash line also has the highest emissions of carbon dioxide and the highest energy cost per kilogram produced. It is also the potato chips line that has the second highest emissions of carbon dioxide per kilogram produced, but it is the fried products from the PF2 line that has the second highest energy cost per kilogram pro- duced. This is because the fryer in the PF2 line uses oil to heat up the frying oil. Several proposed measures to reduce energy use have been developed. Three of the chimneys that were measured at Chips AB had a lot of excess heat that can be used, it was the potato chips fryer, the PF1 boiler and the PF1 fryer. The best proposed measures is to use the excess heat for space heating and domestic hot water and to heat the blanching water. Together, these measures could at best be able to provide an annual saving of approximately € 516,000, and still have a payback period of less than a year. Other proposed measures that also were inves- tigated were preheating of the air to the potato chips boiler, absorption cooling and power generation, but these proposals had less savings and longer payback periods than the first pro- posals.
8

Energiutredning av en villa i Älvkarleby samt lönsamhetsanalys av solceller

Umer, Diyar January 2021 (has links)
Energiutredning av gamla fastigheter är en betydelsefull åtgärd i dagens samhälle för att kunna identifiera och föreslå energieffektiviseringsåtgärder för att kunna minska dess totala energianvändning.Avsikten med denna utredning är att framställa olika förslag för att minimera energianvändningen för en villa i Älvkarleby samt analysera lönsamheten för en installation av en solcellsanläggning. Det undersökta objektet är en 1860-tals timmervilla med en boarea på cirka 400 m2 uppdelat på två våningar, villan renoverades ett antal gånger, då senast tilläggisolerades taket och installerades en luft-luftvärmepump för att minimera elkostnader.En modell skapades i IDA ICE-programmet i avsikt att kunna dela upp de olika energiförluster genom byggnadsskalet såsom tak, golv, väggar och fönster.En installation av en ny luft-luftvärmepump kan ge till resultat att energianvändningen minskas ytterligare med 20 %, detta eftersom den aktuella luft-luftvärmepumpen redan har minskat energianvändningen och därmed elkostnader. Denna typ av värmepump valdes då den har låga installationskostnader samt att det redan existerar en luft-luftvärmepump. Återbetalningstiden för den nya luft-luftvärmepumpen blir 3 år, detta kan dock variera beroende på drifttiderna genom åren.Solcellernas lutning och orientering är oftast optimerade för att maximera den totala årliga elproduktionen. Ändå kan detta inte alltid vara lönsamt utifrån det ekonomiska perspektivet.Ett flertal anläggningar testades med avseende på deras effekt och väderstreck då fastigheten har ett begränsat tak area i söderläge, detta gjordes med hjälp av WINSUN PV-programmet. En solcellsanläggning riktad mot syd och öster på 4,1 kW ansågs vara mest lönsamt bland de undersökta anläggningar då denna anläggning sparar nästan 89% av den producerade elen, då den används direkt i fastigheten.Kostnaden per kW blir lägre ju större anläggningen blir, vilket gör att anläggningen kommer att ha en ungefärlig återbetalningstid på 15 år. Men detta kan troligen påverkas av framtida elpriser, ekonomiska understöd samt fastighetens elanvändning under sommarperioden.
9

ENERGY INVESTIGATION, GÄRTUNA : On the facilities of Astra Zeneca, with suggestions of energy optimizations

Björk, Magnus January 2015 (has links)
AstraZeneca is one of the largest biopharmaceutical companies in the world, and one of the facilities they have is located in Gärtuna, Södertälje. The facility itself is very big with a floor area of 560.000m2 and has a complex energy system. Caverion holds a facility management contract at AstraZenca, hence operates some of the energy system. The energy investigation of this thesis is part of the work of Caverion to ensure a sustainable energy system in Gärtuna. The energy investigation will include mapping of the energy distribution, seeking for potential of improvements and carry out suggestions for energy optimizations. The methods used during the investigation was a literature study, interviews with personnel of both Caverion and AstraZenca, study of the energy system and calculations relevant to the field of study. The mapping of the energy system includes the heat, steam and cooling distribution. When the mapping of the system was done it was clear that the areas with most potential for improvements were the steam and cooling distribution.The mapping of the steam distribution shows a loss of nearly 46% of the steam at year 2014 and the corresponding cost of about 13,640,000 SEK. Even though the steam distribution showed great potential for improvements, it was found that the work of investigating the system would be too difficult for the scope of the thesis. The cooling distribution however is more accessible and the potential is still high due to low coefficient of performance. Two suggestions for energy optimizations were carried out. The first suggestions involves upgraded electric fan motors for some of the cooling towers, and the second suggestion is to modify existing dry coolers in benefit to utilize free cooling during winter period. The fan motor upgrade based on calculations is estimated to result in a yearly energy saving of at least 1526 MWh and a corresponding cost saving of at least 800,000 SEK per year after the pay-off time (9 months). The dry cooler modification based on calculations is estimated to result in a yearly energy saving of 3053 MWh and a yearly cost saving of 2,083,449 SEK after the pay-off period of 5 months. The investigation carried out in this thesis is relevant to both Caverion and AstraZeneca as it points out the areas with potential of improvements and also gives suggestions on energy optimizations that will reduce energy consumption and result in energy cost savings.
10

Framtidens enbostadshus : Att bygga på höjden med minimerad bostadsarea utformat enligt framtida energikrav / The future one-family house : Building high with a minimum gross internal area designed according to future energy requirements

Gustafsson, Pernilla, Loberg, Johan January 2014 (has links)
Tomtmarkerna i urban bebyggelse blir allt mer attraktiva. En minskning av byggnadsarean medger positiva ekonomiska effekter på markkostnaden då tomtpriserna tenderar att bli allt högre i stadsmiljö. En stor del av totalkostnaden vid nyproduktionen av ett enbostadshus är tomtpriset. Framtidens enbostadshus bör utformas med ett begränsat tomtbehov samt uppfylla framtida energikrav.   Examensarbetet har utförts i samarbete med småhustillverkaren Eksjöhus, vilka till följd av de ökade markpriserna upplever en minskad efterfrågan för nyproduktion av småhus. Likt övriga hustillverkare står Eksjöhus också inför uppfyllandet av framtida energikrav.   Syftet med examensarbetet är att utforma framtidens enbostadshus, genom att effektivisera tomtutnyttjandet och förbättra energiprestandan. Frågeställningarna vilka besvaras i arbetet är ”Vilken är den minsta möjliga bostadsarean för entréplanet i ett enbostadshus, med bibehållen tillgänglighet enligt svenska krav?”, ”Hur kan rumsfunktionerna disponeras för ett enbostadshus i tre våningar med bibehållna boendekvalitéer?”, ”Hur kan ett enbostadshus utformas för att klara EUs direktiv för år 2020 beträffande byggnaders energiprestanda?”. Målet med arbetet är att utforma ett enbostadshus i tre våningar med minsta möjliga bostadsarea på entréplanet, som klarar EUs direktiv för år 2020 beträffande byggnaders energiprestanda.   En litteraturstudie genomfördes för att utreda kompaktboendets effekter på boendekvalitén samt energieffektiv byggnadsutformning. En fallstudie av tre byggnader utreddes boende i flera plan. Utformningen av framtidens enbostadshus genomfördes i ett skissarbete och slutligen beräknades byggnaden för att uppfylla den rådande kravspecifikationen för NNE-hus.   En yteffektiv planutformning åstadkoms genom överlappandet av betjäningsareor, effektiv disposition av rumsfunktioner samt gemensamma kommunikationsytor. Entréplanets utformning resulterade i en bostadsarea på 51,4 m2. Byggnaden är utformad för att tillgodose kravet på tillgänglighet i enlighet med BBR och SIS. Rumsfunktionerna som finns representerade på entréplanet är kök, badrum, avskiljbar sängplats samt utrymme för sittgrupp, matplats, tvätt och förvaring. Plan 2 utgörs till största del av ett vardagsrum vilket knyts samman med entréplanets sociala funktioner. Byggandens privata våning utgörs av plan 3 vilket inrymmer två av byggandens tre sovrum.   Byggnaden följer nu gällande krav för 2020-målet, utformat som ett NNE-hus genom en energieffektiv utformning och egenproduktion av el från solceller. Vår slutsats är att förhållande, disponering, kommunikation av rumsfunktioner samt åtskild placering av privata och sociala utrymmen är väsentligt för att minimera bostadsarean samt för att bibehålla en god bostadskvalité. / Building plots in urban settlements are becoming more attractive. A reduction of the gross floor area allows a positive economic impact on the cost when the prices tend to become high in urban settlements. A large amount of the total cost for the production of a new one-family house is the price of the building plot. The future one-family house should be designed with a limited need of land and also meet future energy demands.   The work was performed in collaboration with the small house manufacturer Eksjöhus, which due to the increased price of land are experiencing a decline in demand for construction of new one-family houses. Like the rest of the small house manufacturer, Eksjöhus are also facing the fulfillment of future energy requirements.   The purpose of this study is to design tomorrow's one-family house, by increasing the efficiency of land use and to improve the energy performance. The questions, which are answered in this work are "What is the minimum floor space for the ground floor of a one-family house, while maintaining accessibility according to Swedish demands?", "How can room functions be arrange for a one-family house in three floors with maintained housing qualities?", "How can a one-family house be designed to meet the future EU energy strategy towards 2020 concerning energy performance of buildings? ". The goal of this work is to design a one-family house in three floors with a minimum floor space on the entrance floor, which meet the future EU energy strategy towards 2020.   A literature study was conducted to investigate the impact of compact living on the living quality and energy efficient building design. In a case study of three buildings, housing in several floors was investigated. The design of a future onefamily house was conducted in a sketch work and finally the building was calculated to fulfill the current specification for a Zero-energy building.   A space-efficient plan design is accomplished by overlap the service areas, efficient disposition of room functions and by shared communication areas. The design of the entrance floor resulted in a gross internal area of 51,4 m2. The building is designed to meet the requirement of accessibility according to BBR and SIS.   Room functions which are represented on the entrance floor are kitchen, bathroom, separable bed space and space for sitting, dining, laundry and storage. Plan 2 consists of a large living room which is connected to the social functions on the entrance floor. The private floor of the building is plan 3 which consist of two of the building's three bedrooms.   The building is designed to meet the future EU energy strategy towards 2020. The building is a Zero-energy building due to the energy efficient design and the selfproduction of electricity from solar cells.   Our conclusion is that the relationship, disposition, communication and the separate placement of private and social spaces is essential to reduce the living space and to maintain good housing quality.